Visit us at www.dekoroncable.com
InstrumentPairs/triads
ThermocoupleExtension grade
High Temperature
ControlUL - multi-conductor
CSA - multi conductor(Teck 90®)
UL 1309 ShipboardInstrumentation, Type XCables, 300V or 600V
Foundation Field-Bus Cables2-Way digital communicationcable
Circuit IntegrityInstrument andControl Cable
Sensor CablesUL - multi-conductor(Power-Gen industry)
UL: 300V or 600V, PLTC/ITC, ICEA S-73-532C(UL) Type ACIC 600VCSA CIC (600V)ACICAS/NZS 5000.1 – 600/1000V AS/NZS 5000.3 – 450V /750VAS/NZS 3808UL:PLTC
UL Type TC (Tray Cable)UL Type MC (Metal Clad)ICEA S-73-532AS/NZS 5000.1 – 600/1000VAS/NZS 5000.3 – 450V /750VAS/NZS 3808
CSA CIC 600V
TC-ERUL 1309IEEE 1583
FF-844 H1 and IEC 61158-2ITC, PLTCITC-ER, PLTC-ER,
UL PLTC/ITCICEA S-73-532UL Type TC (Tray Cable)IEC 60331
UL Type TC (Tray Cable)
Shield Options
22-12 AWGBare and Plated Copper,
solid and stranded
Type KX, JX, EX, TX, NX AND SX20-16 AWG, solid and stranded
Copper or Thermocoupleconductors as indicated above.
20-6 AWG
14-10 AWG
AWG 22 - 10 (300V)AWG 18 - 10 (600V)
16-18 AWG
20-10 AWG
16-10 AWG, Copper & plated Cu
PVCPVC/NylonXLPE (Cross-linked PE)TPE (Thermoplastic Elastomer)
FEP (200°C)PFA (260°C)
PVCPVC/Nylon
XLPESilicone
PVCXLPE
XLPE
XLPE or HDXLPE
Silicone Alloy
PVCPVC/NylonFluopolymers (FP)
* Armor designations
PVCCPELSZHPE
FEPPFA
PVCCPE
LSZH
PVC
PVC
PVCCPETPN (LSZH)
Thermo-PlasticZero-Halogen
PVCCPEFP
SWA, ILA, ILGS, DKB, CCWA (Gardex), SS
SS
Only UL Type MC allows ILA, ILGS and CCWA
ILA, ILGS
N/A
ILGS, ILA, DKB, CCWA
SWA, ILA, ILGS, DKB, CCWA (Gardex), SS
SS
1 to 100 Pairs3.7" max diameter for jacketing,3.25" max dia for SWA, 1.75" max dia for ILGS & .800" max dia for CCWA
Contact us
Same as instrumentation cables (depending on gage)
Single and multi pair
Available uponRequest:
"-50°C Arctic Grade" jacket-40°C UL approved cablesITC-ER, PLTC-ER,Direct Burial,Low Smoke Zero Hal
TC-ERMC-HL
Cables pass IEC 6033190 minutes 750°C and Modified Hydro CarbonFuel test (1100°C for20 minutes)
ATEX and IECEx Compliant, Gas-Block™Cables
** Approval standards:Not all approvals are available for all combinationsof insulation and armor types
ILA Interlocked Aluminum Ind and O/A, Al/Poly ILGS Interlocked Galvanized Steel taped shield.SWA Served Wire Armor (Galvanized Steel) Copper and bronze tapes,DKB Dekabon Chemical/Moisture Barrier (Zetabon) Braided copper andCCWA Gardex ® Continuously Corrugated & Welded Al plated copperSS Stainless Steel Overbraid
**
Instrumentation cables come in multiple twisted pair configurations with each pair gathering one set of process data. Our cables are used worldwide in petro-chemical and refining industries, such as BP, Valero, Exxon, Aramco, Conoco-Phillips and Star Petroleum. We have a large number of part numbers in stock, but we can also build cables with any of your specific customizations.
Instrumentation Cables
Multi-pair instrumentation cable with individual and overall shield
Multi-pair instrumentation cable with served wire armor of galvanized steel
We have the most reputed brand name for instrumentation cables. Dekoron Wire and Cable pioneered the development of instrumentation cables for process industry starting in the 1940’s. These cables monitor process parameters such as pressure, flow speed, temperature and transmit low voltage signals to the instrumentation and process control room.
Fieldbus cable are all digital, two way, multi-drop communication cables used in field instruments and control systems.
Field Bus Cables
Control Cables
When regulatory requirements do not mandate conventional metal armor, braided stainless steel is a less expensive option. Stainless steel braid will provide excellent abrasion resistance and flexibility.
Braided Stainless Steel
Stainless Steel Over Braid
Visit us at www.dekoroncable.com
Visit us at www.dekoroncable.com
Dekoron offers a wide range of specialty and composite cables that will suit your needs.We can also provide a combination of data (Cat5 or Cat6) cables and fiber cables along with instrumentation cables under one common armor.
Specialty and Composite Cable
Cable with power, data and tubing components with served wire armor
Custom Cable Category Cable with Gardex armor
The Gardex armor meets the UL MC-HL, Class I Division I criteria and is widely popular in the US for hazardous location applica-tions. We have the ability to apply this type of armor to a variety of cables. See CCWA armor in the data tables.
Gardex® Cables