+ All Categories
Home > Documents > PCEA Continuous Regional Analgesia

PCEA Continuous Regional Analgesia

Date post: 12-Mar-2022
Category:
Upload: others
View: 3 times
Download: 0 times
Share this document with a friend
2
Rythmic TM PCEA Organiser series PCEA pump and sets are colour coded to prevent medication delivery error Experts in ambulatory infusion devices Truly ambulatory system, integrating 50 to 500ml standard bags Ambulatory design • Compact and lightweight • Integrates all bags from 50 to 500 ml (AstraZeneca, Baxter, B Braun, Fresenius…) • With a handle and detachable pole clamp • Optional key lock Reduced alarm activity • Automatic restart of infusion after occlusion release • Higher occlusion detection setting • Long battery autonomy (7 days at 2ml/h) Simple to program • Customisation of the programming menu according to the user protocol • Easy and complete access to historical data during infusion • User interface, history and downloads avai- lable in 15 languages Innovative “all in one” safety set • including spike, anti free flow valve, 2.2 m extension line, filter Continuous epidural, peripheral nerve blocks and wound infiltration analgesia com- monly require the use of pre-filled large standard capacity bags. Patients are becoming more mobile in their reco- very period. Improved management of these large bags hanging beside the infusion pump and associated accessories (sets, pole clamp, hand set, power supply…) is needed. In addition the users require a safe, simple system, wi- thout frequent alarms, risk-free programming and a trustworthy history back up. Micrel is offering the Rythmic Organizer concept to optimize all the components of infusion analgesia, providing full mobility for the patient with a safe and reliable device. PCEA Continuous Regional Analgesia FIche_PCEA_10_09 25/02/10 15:53 Page 1
Transcript

RythmicTM PCEA Organiser seriesPCEA pump and sets are colour coded to prevent medication delivery error

E x p e r t s i n a m b u l a t o r y i n f u s i o n d e v i c e s

Truly ambulatory system,

integrating 50 to 500ml

standard bags

Ambulatory design• Compact and lightweight• Integrates all bags from 50 to 500 ml(AstraZeneca, Baxter, B Braun, Fresenius…)

• With a handle and detachable pole clamp• Optional key lock

Reduced alarm activity• Automatic restart of infusion after occlusion release

• Higher occlusion detection setting • Long battery autonomy (7 days at 2ml/h)

Simple to program• Customisation of the programming menuaccording to the user protocol • Easy and complete access to historical dataduring infusion• User interface, history and downloads avai-lable in 15 languages

Innovative “all in one” safety set • including spike, anti free flow valve, 2.2 mextension line, filter

Continuous epidural, peripheral nerve blocks and wound infiltration analgesia com-monly require the use of pre-filled large standard capacity bags. Patients are becoming more mobile in their reco-very period. Improved management of these large bags hanging beside the infusion pump and associated accessories(sets, pole clamp, hand set, power supply…) is needed. In addition the users require a safe, simple system, wi-thout frequent alarms, risk-free programming and a trustworthy history back up.Micrel is offering the Rythmic Organizer concept to optimize all the components of infusion analgesia, providingfull mobility for the patient with a safe and reliable device.

PCEA

Continuous RegionalAnalgesia

FIche_PCEA_10_09 25/02/10 15:53 Page 1

E x p e r t s i n a m b u l a t o r y i n f u s i o n d e v i c e s

All the range is also available with the Rythmic Plus device for non Epidural/Regional therapies

Plug and play printer forevents down load

Rythmic Plus Organiser 501for non PCEA therapies

Rythmic PCEA with 160 ml bagRythmic PCEA Organiser 501Rythmic Organiser 500 series

• continuous • bolus only • continuous + bolus +/- 5 %0.1 to 100 ml/hml/mg/µg0.1 to 99.9 mg/ml - 0.1 to 999.9 µg/ml1 to 9999 ml0 or from 0.1 to 60 ml with 0.1 ml increment0 to 999 minutesDose limitation over a period of timeLimitation of number of bolus /x hoursLoading dose; Clinician bolus override

0.1 to 2.0 ml/hYes

Air in line eliminator, free flow protection according to IEC 601-2-24

Occlusion (higher setting on PCEA versions), near end and end of infusionLow and depleted batteryDose limit, bolus limitOpen mechanism, preventive maintenance warning…3Yes, including 6500 time stamped events event logPlug and play print facility90 to 240 V, 50-60 Hz (delivered with adaptor)

7 days at 2 ml/h3 hAlso available90 to 240 V, 50-60 Hz

Rythmic Organiser specifications

730 g148 x 249 x 69 mmFitting standard bags up to 100mlOptional, ref. KS5.01.525.xIncludedKP5.04.053.x

840 g157 x 299 x 82 mmFitting standard bags up to 500mlIncludedOptional, ref. KM1.YY.418.xKP5.04.046.x

290 g130 x 133 x 46 mm Fitting 160ml custom bagOptional, ref. KS5.01.430.xIncludedKP5.04.025.x

Weight with batteryDimensions with transparent locker

Pole clampCarrying bag

Ordering references

Yellow Spike set S

Yellow Full set

Spike set S

Spike set S Y

www.micrelmed.com

Delivery modesAccuracy

Flow rate

Programming units Concentration

Volume to infuseBolus dose

Lockout interval

Special functions

KVOAutomatic restart of infusion

after occlusion release

Safety features

Alarms & warnings

Access code levelsHistory, infusion graph /

printout and PC downloadPower supply

Internal Battery lifeInternal Battery charging timeDisposable 9 V battery version

Power supply

Rythmic PCEA Organiser 101 Rythmic PCEA Organiser 501 Rythmic PCEA

KM1.EE.162.x

KM1.EE.161.x

KM1.EE.155.x

KM1.EE.187.x

Info

rmat

ion

in t

his

docu

men

t ar

e co

rrec

t at

tim

e of

pri

ntin

g

ML0

40.B

RO-0

9/07

/09

Contact :[email protected]

FIche_PCEA_10_09 25/02/10 15:53 Page 2