+ All Categories
Home > Documents > PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture...

PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture...

Date post: 30-Aug-2019
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
41
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor
Transcript
Page 1: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 2: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

DV

® USC®

Venture Lighting India Ltd. - MEPZ, Chennai

1

Introduction

Venture Lighting India Limited is a subsidiary of

Venture Lighting International Inc. USA which is an

integral part of Advanced Lighting Technologies

Inc. USA (ADLT)

Venture Lighting International is primarily

involved in the metal halide research, design and

manufacturing operations and is internationally

recognized as an innovator in the lighting industry.

Venture Lighting India Limited, located in the

Madras Export Processing Zone (MEPZ) stated its

manufacturing operations from 1998. With an

establishment that operates the state-of-the-art

manufacturing systems, aided by over 1000 well-

trained professionals, as well as a full-fledged R&D

engineering team and facility. Venture marched

right ahead, into a bright white future.

Venture Lighting India Ltd. Is currently the largest

manufacturer of Metal Halide Lamps in the Asia

Pacific region, producing approx 5,00,000 lamps.

2,00, 000 ballasts and 2,00,000 ignitors every

month, occupying manufacturing area of around

1,25,000 sq.ft. for Lamps and 6,50,000 sq.ft. for

Ballasts & IBUs.

Venture Lighting India Ltd. Possesses an ISO

9001:2008 and ISO 14001:2004 certification as well

as eight prestigious international regulatory

approvals in keeping with the world's most

stringent standards. Owing to these factors by

large, Venture towers over ever y other

manufacturer in terms of Quantity as well as

Quality of its Metal Halide Lighting Systems.

Over a period of time, Venture has been aggressive

in its endeavor to innovate and develop

environment friendly Metal Halide lighting

products designed for a wide range of Indoor &

Outdoor applications.

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 3: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

QualityŸExclusive formed body arc tube for consistency beyond ceramic

metal halide

ŸPatented stronger weldless mount construction to minimise delivery and handling breakages

Ÿ'Formed Body' arc tube improves performance for maximum colour and light output uniformity

PerformanceŸLonger lamp life

ŸEnhanced lumen maintenance

ŸExcellent system colour uniformity

ŸHot restart in less than half the time of standard pinch body metal halide systems

Ÿ50% faster warm-up

SafetyŸShrouded 'open-rated' lamps to provide protection for luminaires

without lensesŸUV Shield - blocks up to 80% UV, 50% more than most UV-reducing

lamps

ŸReduces UV damage to merchandise and signage

ŸAdditional GlassGuard coating available for additional protection against breakage

SelectionŸVenture's Uni-Form pulse start series of lamps has the greatest

selection of lumen packages: 35W to 400W

ŸMost comprehensive range of open-rated products available in the industry

Venture’s Unique Formed Body Arc Tube TechnologyŸSuperior colour uniformity, less deviation from lamp to lamp -

Consistency beyond ceramic metal halide

ŸHighest lamp efficacy

ŸPatented stronger weldless arc tube mounting technology

ŸHigher maintained lumens, longer lamp lifeŸHot restart in less than half the time of regular metal halide

Ÿ50% faster warm-up

Unique formedbody arc tube -shaped to followthe curve of thearc stream todeliver superiorlamp efficacy

Safety shroud withUV Shield® -blocks up to 80%UV, 50% more thanmost UV-reducinglamps to preventPolycarbonatefixtures fromyellowing

Patented strongerweldless mountconstruction -no welds meanless breakageduring shippingand handling

Simply a Better Metal Halide Lamp

The Secret is in the Shape

White-Lux - HPS Replacement Lamps

It's quick and simple to get rid of old, high-pressure sodium lighting – with White-Lux Plus Metal Halide lamps from Venture Lighting.

White-Lux Plus lamps can operate directly from existing HPS control gear.

Even 'difficult' 70W HPS lamps with internal starters can be directly replaced, using a simple conversion kit.

So why put up with murky yellow-tinged sodium lighting when it's never been easier or more cost effective to switch – and enjoy the clean, fresh and natural white light of metal halide lamp technology!

From the world leaders in metal halide technology

ŸUnique Venture Uni-Form formed body arc tube

ŸFaster warm-up and hot restart

ŸIncreased efficiency

ŸLong life – up to 20,000 hours

ŸBetter lamp-to-lamp consistency

ŸA full range of ratings from 50 to 400 watts

ŸA choice of tubular and elliptical designs

ŸClear or coated outer jackets

ŸFor use in open or enclosed fittings

ŸNo thermal cut-out ballasts required

ŸEnvironmentally friendly UV shields available for fittings with poly-carbonate lenses

32PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 4: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

QualityŸExclusive formed body arc tube for consistency beyond ceramic

metal halide

ŸPatented stronger weldless mount construction to minimise delivery and handling breakages

Ÿ'Formed Body' arc tube improves performance for maximum colour and light output uniformity

PerformanceŸLonger lamp life

ŸEnhanced lumen maintenance

ŸExcellent system colour uniformity

ŸHot restart in less than half the time of standard pinch body metal halide systems

Ÿ50% faster warm-up

SafetyŸShrouded 'open-rated' lamps to provide protection for luminaires

without lensesŸUV Shield - blocks up to 80% UV, 50% more than most UV-reducing

lamps

ŸReduces UV damage to merchandise and signage

ŸAdditional GlassGuard coating available for additional protection against breakage

SelectionŸVenture's Uni-Form pulse start series of lamps has the greatest

selection of lumen packages: 35W to 400W

ŸMost comprehensive range of open-rated products available in the industry

Venture’s Unique Formed Body Arc Tube TechnologyŸSuperior colour uniformity, less deviation from lamp to lamp -

Consistency beyond ceramic metal halide

ŸHighest lamp efficacy

ŸPatented stronger weldless arc tube mounting technology

ŸHigher maintained lumens, longer lamp lifeŸHot restart in less than half the time of regular metal halide

Ÿ50% faster warm-up

Unique formedbody arc tube -shaped to followthe curve of thearc stream todeliver superiorlamp efficacy

Safety shroud withUV Shield® -blocks up to 80%UV, 50% more thanmost UV-reducinglamps to preventPolycarbonatefixtures fromyellowing

Patented strongerweldless mountconstruction -no welds meanless breakageduring shippingand handling

Simply a Better Metal Halide Lamp

The Secret is in the Shape

White-Lux - HPS Replacement Lamps

It's quick and simple to get rid of old, high-pressure sodium lighting – with White-Lux Plus Metal Halide lamps from Venture Lighting.

White-Lux Plus lamps can operate directly from existing HPS control gear.

Even 'difficult' 70W HPS lamps with internal starters can be directly replaced, using a simple conversion kit.

So why put up with murky yellow-tinged sodium lighting when it's never been easier or more cost effective to switch – and enjoy the clean, fresh and natural white light of metal halide lamp technology!

From the world leaders in metal halide technology

ŸUnique Venture Uni-Form formed body arc tube

ŸFaster warm-up and hot restart

ŸIncreased efficiency

ŸLong life – up to 20,000 hours

ŸBetter lamp-to-lamp consistency

ŸA full range of ratings from 50 to 400 watts

ŸA choice of tubular and elliptical designs

ŸClear or coated outer jackets

ŸFor use in open or enclosed fittings

ŸNo thermal cut-out ballasts required

ŸEnvironmentally friendly UV shields available for fittings with poly-carbonate lenses

32PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 5: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

Open Rated Lamps

Description Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

PositionOperating

Current (A)Carton

Qty.Control

Gear

HIPE 70 W/C/U/LU/UVS/4K 10003 5000 15000 3700 70 71 Universal 0.90 12 MH / HPSVHIPE 100 W/C/U/LU/UVS/4K 10005 8100 15000 3700 70 81 Universal 1.10 12 MH / HPSVHIPE 150 W/C/U/LU/UVS/4K 10007 12600 15000 3700 70 84 Universal 1.80 12 MH / HPSV

Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

Position Lamp

Op. Cur. (A)Carton

Qty.Control

GearDescription

HIPE 150 W/C/U/LU/E90/UVS/4K 10082 12600 15000 3700 70 84 Universal 1.80 12 MH / HPSVHIPE 200 W/C/V/UVS/PS/4K 10059 19000 15000 3700 70 95 Vertical ± 15* 1.60 12 MHHIPE 250 W/C/HBU/LU/UVS/4K 10076 20000 15000 3700 70 80 Base Up ± 90* 3.10 12 MH / HPSVHIPE 250 W/C/BU/UVS/PS/4K 10014 22600 15000 3700 70 90 Base Up ± 15* 2.10 12 MH / HPMVHIPE 320 W/C/V/PS/4K 40904 31000 20000 3700 70 97 Vertical ± 15* 2.63 6 MHHIPE 400 W/C/BU/LU/UVS/4K 10043 40000 20000 3700 70 100 Base Up ± 15* 4.00 6 MH / HPSVHIPE 400 W/C/BU/PS/4K 10041 40000 20000 3700 70 100 Base Up ± 15* 3.20 6 MH / HPMV

Clear Lamps are available upon request * When operated in vertical burn position

Open RatedElliptical Lamps

High energy savingsHigh lumen efficiencyLonger life (up to 20,000 hrs.)

Retrofit versions for HPS / HPMV lampsBetter cold startingUV Shield available

Features

Industrial lightingWarehousesAmenity lighting

Applications

Parking lotsFoundriesAssembly Shops

Enclosed Rated

Enclosed Rated Lamps

Description Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

PositionOperating

Current (A)Carton

Qty.Control

Gear

HIE 50 W/C/U/LU/4K 83630 3200 10000 3700 70 64 Universal 0.68 12 MH / HPSVHIE 70 W/C/U/LU/3K 96720 5300 15000 3200 70 76 Universal 0.90 12 MH / HPSVHIE 70 W/C/U/LU/4200K 15631 5300 15000 4200 70 76 Universal 0.90 12 MH / HPSVHIE 100 W/C/U/LU/4K 19031 8500 15000 3700 70 85 Universal 1.10 12 MH / HPSVHIE 125 W/C/U/4K 97765 10700 12000 3700 70 86 Universal 1.10 12 MH / HPMVHIE 150 W/C/U/LU/3K 69876 13300 15000 3200 70 89 Universal 1.80 12 MH / HPSVHIE 150 W/C/U/LU/4200K 26514 13300 15000 4200 70 89 Universal 1.80 12 MH / HPSV

Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

Position Lamp

Op. Cur. (A)Carton

Qty.Control

GearDescription

MH 150 W/C/U/ED28/PS 21344 13300 15000 3700 70 89 Universal 1.80 12 MH / HPSVHIE 175 W/C/U/EURO/4K 40698 13300 10000 3700 70 76 Universal 1.50 12 MH HIE 200 W/C/U/PS/4K 10058 20000 15000 3700 70 100 Universal 1.60 12 MHHIE 250 W/C/BU/LU/4K 56266 21000 15000 3700 70 84 Base Up ± 15* 3.10 12 MH / HPSVHIE 250 W/C/BU/PS/4K 61513 23800 15000 3700 70 95 Base Up ± 15* 2.10 12 MH / HPMVHIE 250 W/C/U/LU/PB/4K 73336 21000 15000 3700 70 84 Universal 3.10 12 MH / HPSVHIE 250 W/C/U/EURO/4K 21303 20000 10000 3700 70 80 Universal 2.01 12 MH / HPSVMHE 250 W/C/V/LU/5K 45714 19000 10000 6500 85 76 Vertical ± 15* 3.10 12 MH / HPSVMHE 250 W/C/V/PS/5K 89456 19000 10000 6500 85 76 Vertical ± 15* 2.10 12 MH / HPMVMS 320 W/C/V/ED37/PS/737 67712 31000 20000 3700 70 97 Vertical ± 15* 2.63 6 MHHIE 400 W/C/BU/LU/4K 54695 42000 20000 3700 70 95 Base Up ± 15* 4.00 6 MH / HPSVHIE 400 W/C/BU/EURO/4K 60444 42000 20000 3700 70 105 Base Up ± 15* 3.20 6 MH / HPMVHIE 400 W/C/BU/EURO/4K 31545 38000 15000 3700 70 95 Base Up ± 15* 3.20 6 MH / HPMVMHE 400 W/C/U/LU/4K 50040 36000 15000 4000 65 90 Universal 301 6 MH / HPMV

Clear Lamps are available upon request * When operated in vertical burn position

Elliptical Lamps

Decorative lightingDown lightingIndustrial lighting

LandscapeParking garagesWarehouses

Applications

Precise small light sourceAvailable in clear and coated versionsFaster warm-up and hot re-strike

Wide range of colour temperaturesSuperior lumen maintenanceBetter cold starting

Features

54PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 6: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

Open Rated Lamps

Description Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

PositionOperating

Current (A)Carton

Qty.Control

Gear

HIPE 70 W/C/U/LU/UVS/4K 10003 5000 15000 3700 70 71 Universal 0.90 12 MH / HPSVHIPE 100 W/C/U/LU/UVS/4K 10005 8100 15000 3700 70 81 Universal 1.10 12 MH / HPSVHIPE 150 W/C/U/LU/UVS/4K 10007 12600 15000 3700 70 84 Universal 1.80 12 MH / HPSV

Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

Position Lamp

Op. Cur. (A)Carton

Qty.Control

GearDescription

HIPE 150 W/C/U/LU/E90/UVS/4K 10082 12600 15000 3700 70 84 Universal 1.80 12 MH / HPSVHIPE 200 W/C/V/UVS/PS/4K 10059 19000 15000 3700 70 95 Vertical ± 15* 1.60 12 MHHIPE 250 W/C/HBU/LU/UVS/4K 10076 20000 15000 3700 70 80 Base Up ± 90* 3.10 12 MH / HPSVHIPE 250 W/C/BU/UVS/PS/4K 10014 22600 15000 3700 70 90 Base Up ± 15* 2.10 12 MH / HPMVHIPE 320 W/C/V/PS/4K 40904 31000 20000 3700 70 97 Vertical ± 15* 2.63 6 MHHIPE 400 W/C/BU/LU/UVS/4K 10043 40000 20000 3700 70 100 Base Up ± 15* 4.00 6 MH / HPSVHIPE 400 W/C/BU/PS/4K 10041 40000 20000 3700 70 100 Base Up ± 15* 3.20 6 MH / HPMV

Clear Lamps are available upon request * When operated in vertical burn position

Open RatedElliptical Lamps

High energy savingsHigh lumen efficiencyLonger life (up to 20,000 hrs.)

Retrofit versions for HPS / HPMV lampsBetter cold startingUV Shield available

Features

Industrial lightingWarehousesAmenity lighting

Applications

Parking lotsFoundriesAssembly Shops

Enclosed Rated

Enclosed Rated Lamps

Description Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

PositionOperating

Current (A)Carton

Qty.Control

Gear

HIE 50 W/C/U/LU/4K 83630 3200 10000 3700 70 64 Universal 0.68 12 MH / HPSVHIE 70 W/C/U/LU/3K 96720 5300 15000 3200 70 76 Universal 0.90 12 MH / HPSVHIE 70 W/C/U/LU/4200K 15631 5300 15000 4200 70 76 Universal 0.90 12 MH / HPSVHIE 100 W/C/U/LU/4K 19031 8500 15000 3700 70 85 Universal 1.10 12 MH / HPSVHIE 125 W/C/U/4K 97765 10700 12000 3700 70 86 Universal 1.10 12 MH / HPMVHIE 150 W/C/U/LU/3K 69876 13300 15000 3200 70 89 Universal 1.80 12 MH / HPSVHIE 150 W/C/U/LU/4200K 26514 13300 15000 4200 70 89 Universal 1.80 12 MH / HPSV

Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

Position Lamp

Op. Cur. (A)Carton

Qty.Control

GearDescription

MH 150 W/C/U/ED28/PS 21344 13300 15000 3700 70 89 Universal 1.80 12 MH / HPSVHIE 175 W/C/U/EURO/4K 40698 13300 10000 3700 70 76 Universal 1.50 12 MH HIE 200 W/C/U/PS/4K 10058 20000 15000 3700 70 100 Universal 1.60 12 MHHIE 250 W/C/BU/LU/4K 56266 21000 15000 3700 70 84 Base Up ± 15* 3.10 12 MH / HPSVHIE 250 W/C/BU/PS/4K 61513 23800 15000 3700 70 95 Base Up ± 15* 2.10 12 MH / HPMVHIE 250 W/C/U/LU/PB/4K 73336 21000 15000 3700 70 84 Universal 3.10 12 MH / HPSVHIE 250 W/C/U/EURO/4K 21303 20000 10000 3700 70 80 Universal 2.01 12 MH / HPSVMHE 250 W/C/V/LU/5K 45714 19000 10000 6500 85 76 Vertical ± 15* 3.10 12 MH / HPSVMHE 250 W/C/V/PS/5K 89456 19000 10000 6500 85 76 Vertical ± 15* 2.10 12 MH / HPMVMS 320 W/C/V/ED37/PS/737 67712 31000 20000 3700 70 97 Vertical ± 15* 2.63 6 MHHIE 400 W/C/BU/LU/4K 54695 42000 20000 3700 70 95 Base Up ± 15* 4.00 6 MH / HPSVHIE 400 W/C/BU/EURO/4K 60444 42000 20000 3700 70 105 Base Up ± 15* 3.20 6 MH / HPMVHIE 400 W/C/BU/EURO/4K 31545 38000 15000 3700 70 95 Base Up ± 15* 3.20 6 MH / HPMVMHE 400 W/C/U/LU/4K 50040 36000 15000 4000 65 90 Universal 301 6 MH / HPMV

Clear Lamps are available upon request * When operated in vertical burn position

Elliptical Lamps

Decorative lightingDown lightingIndustrial lighting

LandscapeParking garagesWarehouses

Applications

Precise small light sourceAvailable in clear and coated versionsFaster warm-up and hot re-strike

Wide range of colour temperaturesSuperior lumen maintenanceBetter cold starting

Features

54PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 7: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

Position Lamp

Op. Cur. (A)Carton

Qty.Control

GearDescription

MH-DE 70 W/UVS/3K 16786 5200 10000 3000 70 69 Hor ± 45* 0.90 25 MH / HPSVMH-DE 70 W/UVS/4K 60248 5500 10000 4200 70 73 Hor ± 45* 0.90 25 MH / HPSVMH-DE 70 W/UVS/6K 79470 4800 10000 6500 80 64 Hor ± 45* 0.90 25 MH / HPSVMH-DE 150 W/UVS/3K 11295 11250 10000 3000 70 75 Hor ± 45* 1.80 25 MH / HPSVMH-DE 150 W/UVS/4K 74756 11250 10000 4200 70 75 Hor ± 45* 1.80 25 MH / HPSVMH-DE 150 W/UVS/6K 29963 10000 10000 6500 80 67 Hor ± 45* 1.80 25 MH / HPSVMBIL S 1000 W 22417 80000 6000 5200 65 80 Hor ± 15* 4.40 6 MHMBIL S 1500 W 22151 130000 6000 5200 65 87 Hor ± 15* 6.70 6 MHMBIL S 2000 W 22132 215000 6000 5200 65 100 Hor ± 15* 10.30 2 MHMHTS 2000 W/L/IC 12/45K 84203 240000 5000 4500 65 112 Hor ± 15* 10.30 MH

Commercial LightingDouble Ended Lamps

Accent lightingFlood lightingDown lightingSports lighting

Applications

Retail environmentsShow roomsArena lighting

Compact configurationPrecise optical controlLong life

Features

Excellent colour uniformityUni-FormTM formed body arc tubeFaster warm-up and hot re-strike

Enclosed RatedTubular Lamps

Tubular E27 Based Lamps

Tubular E40 Based Lamps

Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

Position Lamp

Op. Cur. (A)Carton

Qty.Control

GearDescription

Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

Position Lamp

Op. Cur. (A)Carton

Qty.Control

GearDescription

HIT 70 W/U/LU/4K 13742 5300 15000 4000 65 76 Universal 0.90 12 MH / HPSV

HIT 100 W/U/LU/T38/4K 76738 9000 15000 4000 65 90 Universal 1.10 12 MH / HPSV

HIT 150 W/U/LU/T38/4K 62272 14000 15000 4000 65 93 Universal 1.80 12 MH / HPSV

HIT 150 W/U/LU/T46/4K 71144 14000 15000 4000 65 93 Universal 1.80 12 MH / HPSV

MS 200 W/H75/T15/PS 70764 19000 15000 4000 65 95 Hor ± 75* 1.60 12 MH

HIT 250 W/U/LU/4K 48768 19000 10000 4000 65 76 Universal 3.10 12 MH / HPSV

HIT 250 W/U/LU/5K 10855 16800 10000 5200 75 67 Universal 3.10 12 MH / HPSV

HIT 250 W/U/EURO/4K 33950 21000 10000 4000 65 84 Universal 2.10 12 MH / HPMV

MS 320 W/H75/T15/PS/740 79710 30000 20000 4000 68 94 Hor ± 45* 2.63 12 MH

HIT 400 W/U/LU/4K 98748 36000 15000 4000 65 90 Universal 4.20 12 MH / HPSV

HIT 400 W/U/LU/5K 21044 32000 15000 5200 75 80 Universal 4.20 12 MH / HPSV

HIT 400 W/U/EURO/4K 25830 36000 15000 4000 65 90 Universal 3.20 12 MH / HPMV

HIT 400 W/HDR/EURO/4K 88410 40000 15000 4000 65 100 Hor ± 45* 2.1 12 MH / HPSV

HIT 600 W/U/LU/4K 54631 50000 12000 4000 65 83 Universal 6.20 6 MH / HPSV

HIT 1000 W/U/LU/4K 83265 90000 8000 4000 65 90 Universal 10.30 6 MH / HPSV

* When operated in horizontal burn position

* When operated in horizontal burn position

Faster warm-up and hot re-strikeEnergy saving wattagesWide range of colour temperaturesSuperior lumen maintenance

Retrofit versions for HPS / HPMV lampsAvailable from 70 - 1000 WBetter colour uniformityBetter cold starting

Features

Flood lightingSecurity lightingSports lightingAmenity lighting

Applications

Architectural lightingYard lightingHoarding lightingEnergy retrofits

76PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 8: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

Position Lamp

Op. Cur. (A)Carton

Qty.Control

GearDescription

MH-DE 70 W/UVS/3K 16786 5200 10000 3000 70 69 Hor ± 45* 0.90 25 MH / HPSVMH-DE 70 W/UVS/4K 60248 5500 10000 4200 70 73 Hor ± 45* 0.90 25 MH / HPSVMH-DE 70 W/UVS/6K 79470 4800 10000 6500 80 64 Hor ± 45* 0.90 25 MH / HPSVMH-DE 150 W/UVS/3K 11295 11250 10000 3000 70 75 Hor ± 45* 1.80 25 MH / HPSVMH-DE 150 W/UVS/4K 74756 11250 10000 4200 70 75 Hor ± 45* 1.80 25 MH / HPSVMH-DE 150 W/UVS/6K 29963 10000 10000 6500 80 67 Hor ± 45* 1.80 25 MH / HPSVMBIL S 1000 W 22417 80000 6000 5200 65 80 Hor ± 15* 4.40 6 MHMBIL S 1500 W 22151 130000 6000 5200 65 87 Hor ± 15* 6.70 6 MHMBIL S 2000 W 22132 215000 6000 5200 65 100 Hor ± 15* 10.30 2 MHMHTS 2000 W/L/IC 12/45K 84203 240000 5000 4500 65 112 Hor ± 15* 10.30 MH

Commercial LightingDouble Ended Lamps

Accent lightingFlood lightingDown lightingSports lighting

Applications

Retail environmentsShow roomsArena lighting

Compact configurationPrecise optical controlLong life

Features

Excellent colour uniformityUni-FormTM formed body arc tubeFaster warm-up and hot re-strike

Enclosed RatedTubular Lamps

Tubular E27 Based Lamps

Tubular E40 Based Lamps

Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

Position Lamp

Op. Cur. (A)Carton

Qty.Control

GearDescription

Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

Position Lamp

Op. Cur. (A)Carton

Qty.Control

GearDescription

HIT 70 W/U/LU/4K 13742 5300 15000 4000 65 76 Universal 0.90 12 MH / HPSV

HIT 100 W/U/LU/T38/4K 76738 9000 15000 4000 65 90 Universal 1.10 12 MH / HPSV

HIT 150 W/U/LU/T38/4K 62272 14000 15000 4000 65 93 Universal 1.80 12 MH / HPSV

HIT 150 W/U/LU/T46/4K 71144 14000 15000 4000 65 93 Universal 1.80 12 MH / HPSV

MS 200 W/H75/T15/PS 70764 19000 15000 4000 65 95 Hor ± 75* 1.60 12 MH

HIT 250 W/U/LU/4K 48768 19000 10000 4000 65 76 Universal 3.10 12 MH / HPSV

HIT 250 W/U/LU/5K 10855 16800 10000 5200 75 67 Universal 3.10 12 MH / HPSV

HIT 250 W/U/EURO/4K 33950 21000 10000 4000 65 84 Universal 2.10 12 MH / HPMV

MS 320 W/H75/T15/PS/740 79710 30000 20000 4000 68 94 Hor ± 45* 2.63 12 MH

HIT 400 W/U/LU/4K 98748 36000 15000 4000 65 90 Universal 4.20 12 MH / HPSV

HIT 400 W/U/LU/5K 21044 32000 15000 5200 75 80 Universal 4.20 12 MH / HPSV

HIT 400 W/U/EURO/4K 25830 36000 15000 4000 65 90 Universal 3.20 12 MH / HPMV

HIT 400 W/HDR/EURO/4K 88410 40000 15000 4000 65 100 Hor ± 45* 2.1 12 MH / HPSV

HIT 600 W/U/LU/4K 54631 50000 12000 4000 65 83 Universal 6.20 6 MH / HPSV

HIT 1000 W/U/LU/4K 83265 90000 8000 4000 65 90 Universal 10.30 6 MH / HPSV

* When operated in horizontal burn position

* When operated in horizontal burn position

Faster warm-up and hot re-strikeEnergy saving wattagesWide range of colour temperaturesSuperior lumen maintenance

Retrofit versions for HPS / HPMV lampsAvailable from 70 - 1000 WBetter colour uniformityBetter cold starting

Features

Flood lightingSecurity lightingSports lightingAmenity lighting

Applications

Architectural lightingYard lightingHoarding lightingEnergy retrofits

76PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 9: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

Theme ParksArchitectural lightingsBuilding facadesMonument Lighting

Applications

Primary colour generationHighly efficientCompact sizeExcellent optical control

Features

Commercial LightingDesigner Colour Lamps

9

DescriptionPart

Code%

SaturationAvg. LifeHours*

BurnPosition

Operating Current (A)

CartonQty.

Control Gear

HIE 150 W/U/BDX 33051 77 5000 Universal 1.80 12HIE 150 W/U/GDX 33520 46 5000 Universal 1.80 12MH-DE 150 W/UVS/BDX** 33496 77 5000 Hor ± 45** 1.80 25MH-DE 150 W/UVS/GDX** 33851 46 5000 Hor ± 45** 1.80 25HIT 150 W/G12/UVS/BDX 84684 77 5000 Universal 1.80 25HIT 150 W/G12/UVS/GDX 26786 46 5000 Universal 1.80 25HIT 400 W/U/BDX 88342 77 5000 Universal 3.20 12HIT 400 W/U/GDX 64390 46 5000 Universal 3.20 12HIT 400 W/U/PDX 97354 28 5000 Universal 3.20 12HIT 400 W/U/MDX 99990 28 5000 Universal 3.20 12

MH / HPSVMH / HPSVMH / HPSVMH / HPSVMH / HPSVMH / HPSVMH / HPMVMH / HPMVMH / HPMVMH / HPMV

** When operated in Horizontal burn position* When operated in Vertical burn position

Commercial LightingG12 Lamps

8

Description Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

PositionOperating

Current (A)Carton

Qty.Control

Gear

HIT 70 W/G12/UVS/3K 12108 5600 10000 3000 70 75 Universal 0.90 25 MH / HPSVHIT 70 W/G12/UVS/4K 52983 5600 10000 4200 70 75 Universal 0.90 25 MH / HPSVHIT 70 W/G12/UVS/6K 39682 4800 5000 6500 90 64 Universal 0.90 25 MH / HPSVHIT 150 W/G12/UVS/3K 12106 14000 10000 3000 70 93 Universal 1.80 25 MH / HPSVHIT 150 W/G12/UVS/4K 25779 14000 10000 4200 70 93 Universal 1.80 25 MH / HPSVHIT 150 W/G12/UVS/6K 78564 11250 5000 6500 90 75 Universal 1.80 25 MH / HPSV

Down lightingAccent lightingWall sconceTrack lighting

Applications

Compact configurationPrecise optical controlExcellent colour uniformity

TMUni-Form formed body arc tube

Features

* When operated in vertical burn position

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 10: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

Theme ParksArchitectural lightingsBuilding facadesMonument Lighting

Applications

Primary colour generationHighly efficientCompact sizeExcellent optical control

Features

Commercial LightingDesigner Colour Lamps

9

DescriptionPart

Code%

SaturationAvg. LifeHours*

BurnPosition

Operating Current (A)

CartonQty.

Control Gear

HIE 150 W/U/BDX 33051 77 5000 Universal 1.80 12HIE 150 W/U/GDX 33520 46 5000 Universal 1.80 12MH-DE 150 W/UVS/BDX** 33496 77 5000 Hor ± 45** 1.80 25MH-DE 150 W/UVS/GDX** 33851 46 5000 Hor ± 45** 1.80 25HIT 150 W/G12/UVS/BDX 84684 77 5000 Universal 1.80 25HIT 150 W/G12/UVS/GDX 26786 46 5000 Universal 1.80 25HIT 400 W/U/BDX 88342 77 5000 Universal 3.20 12HIT 400 W/U/GDX 64390 46 5000 Universal 3.20 12HIT 400 W/U/PDX 97354 28 5000 Universal 3.20 12HIT 400 W/U/MDX 99990 28 5000 Universal 3.20 12

MH / HPSVMH / HPSVMH / HPSVMH / HPSVMH / HPSVMH / HPSVMH / HPMVMH / HPMVMH / HPMVMH / HPMV

** When operated in Horizontal burn position* When operated in Vertical burn position

Commercial LightingG12 Lamps

8

Description Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

PositionOperating

Current (A)Carton

Qty.Control

Gear

HIT 70 W/G12/UVS/3K 12108 5600 10000 3000 70 75 Universal 0.90 25 MH / HPSVHIT 70 W/G12/UVS/4K 52983 5600 10000 4200 70 75 Universal 0.90 25 MH / HPSVHIT 70 W/G12/UVS/6K 39682 4800 5000 6500 90 64 Universal 0.90 25 MH / HPSVHIT 150 W/G12/UVS/3K 12106 14000 10000 3000 70 93 Universal 1.80 25 MH / HPSVHIT 150 W/G12/UVS/4K 25779 14000 10000 4200 70 93 Universal 1.80 25 MH / HPSVHIT 150 W/G12/UVS/6K 78564 11250 5000 6500 90 75 Universal 1.80 25 MH / HPSV

Down lightingAccent lightingWall sconceTrack lighting

Applications

Compact configurationPrecise optical controlExcellent colour uniformity

TMUni-Form formed body arc tube

Features

* When operated in vertical burn position

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 11: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

Commercial Lighting

Down LightersShopping MallsTrack LightingShowroomsSuper Markets

Applications

Ceramic Lamp & Electronic Ballast

10

Ceramic LampsDescription Part Code Initial

Lumen Life (Hrs) Temp Position QtyCM-PLUS TC20W/U/UVS/G8.5/830 00354 1800 9000 3000 k 80+ 90 Universal 12CM-PLUS TC20W/U/UVS/G8.5/942 00355 1800 9000 4200 k 90+ 90 Universal 12CM-PLUS TC35W/U/UVS/G8.5/830 00356 3400 12000 3000 k 80+ 97 Universal 12CM-PLUS TC35W/U/UVS/G8.5/942 00357 3300 12000 4200 k 90+ 94 Universal 12CM-PLUS TC70W/U/UVS/G8.5/830 00358 7000 12000 3000 k 80+ 100 Universal 12CM-PLUS TC70W/U/UVS/G8.5/942 00359 6600 12000 4200 k 90+ 94 Universal 12CM-PLUS T35W/U/UVS/G12/830 00362 3400 12000 3000 k 80+ 97 Universal 12CM-PLUS T35W/U/UVS/G12/942 00363 3300 12000 4200 k 90+ 94 Universal 12CM-PLUS T70W/U/UVS/G12/830 00364 7000 12000 3000 k 80+ 100 Universal 12CM-PLUS T70W/U/UVS/G12/942 00365 6600 12000 4200 k 90+ 94 Universal 12CM-PLUS T150W/U/UVS/G12/830 00368 15000 12000 3000 k 80+ 100 Universal 12CM-PLUS T150W/U/UVS/G12/942 00369 13500 12000 4200 k 90+ 90 Universal 12CM-PLUS TD70W/U/UVS/Rx7s/830 00370 7000 15000 3000 k 80+ 100 Universal 12CM-PLUS TD70W/U/UVS/Rx7s/942 00371 6600 15000 4200 k 90+ 94 Universal 12CM-PLUS TD150W/U/UVS/Rx7s/830 00372 14000 15000 3000 k 80+ 100 Universal 12CM-PLUS TD150W/U/UVS/Rx7s/942 00373 12500 15000 4200 k 90+ 83 Universal 12CM-PLUS TT70W/U/UVS/830 00374 7000 18000 3000 k 80+ 100 Universal 12CM-PLUS TT70W/U/UVS/942 00375 6600 18000 4200 k 90+ 94 Universal 12CM-PLUS TT150W/U/UVS/830 00378 14000 18000 3000 k 80+ 93 Universal 12CM-PLUS TT150W/U/UVS/942 00379 13500 18000 4200 k 90+ 90 Universal 12

Rated Color CRI LPW Burn Carton

Electronic BallastWattage Part Code Input Voltage Hz Dimensions ( L x W x H)

20 VYB020255 220-240 50-60 109 x 72 x 31 mm35 SH35 220-240 50-60 123 x 77 x 30.5 mm70 SH70GC 220-240 50-60 109 x 76 x 32 mm

150 SH150I 220-240 50-60 176 x 88 x 35.5 mm

Best in Class Color Rendering Index (CRI)Excellent Lumen MaintenanceExceptional Color Consistency & StabilityIncreased Lamp LifeIdeal for Quality Interior DecorsOptimal lamp control and operationEnd of lamp life protectionHigh efficient, low watt lossLess weight and compact

Features

Commercial LightingMH MR16

11

Shopping MallsTrack LightingShow Rooms

Retail LightingShowcase LightingAuto Dealership Showrooms

Applications

Features

Compared to quartz halogen, Venture’s track lighting systemSaving up to 64% energy without sacrificing light levelsup to 31/2 x the light levels4x the lifeHigh CRI lighting, 90+Daylight colour : 5000K CCT, colors of products are truer

Shopping MallsTrack LightingShow Rooms

Retail LightingShowcase LightingAuto Dealership Showrooms

Applications

Features

IR halogen directional light source offering:30% energy savings (37W compared to standard 50W)30% more light output (50W compared to standard 50W)Dichromic coated precision glass reflectorCover lens with UV blocking protectionGU5.3 base for easy replacement and solid connectionConsistent color over life

Description Part Code

Center BeamCandle Power

Beam Angle* Beam Type Rated Life

Hours CCT CRI Lamp Color

MPSE 35W/GX10/MR16/950/SP/WH 60621 19000cd 10 Spot 12000 5000k 90+ WhiteMPSE 35W/GX10/MR16/950/NFL/WH 60631 11200cd 18 Narrow Flood 12000 5000k 90+ WhiteMPSE 35W/GX10/MR16/950/FL/WH 60632 5100cd 30 Flood 12000 5000k 90+ White

Description Part Code

Center BeamCandle Power

Beam Angle* Beam Type Rated Life

Hours

HIR-M 37MR16/IR/FL9 28945 13000 9 Spot 5000HIR-M 37MR16/IR/FL25 35664 4400 25 Narrow Flood 5000HIR-M 37MR16/IR/FL35 55982 2200 35 Flood 5000HIR-M 37MR16/IR/FL60 76371 1100 60 Wide Flood 5000HIR-M 50MR16/IR/FL9 28955 15500 9 Spot 5000HIR-M 50MR16/IR/FL25 35674 5700 25 Narrow Flood 5000HIR-M 50MR16/IR/FL35 55992 2800 35 Flood 5000HIR-M 50MR16/IR/FL60 76381 1400 60 Wide Flood 5000

Commercial LightingHalogen MR16

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 12: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

Commercial Lighting

Down LightersShopping MallsTrack LightingShowroomsSuper Markets

Applications

Ceramic Lamp & Electronic Ballast

10

Ceramic LampsDescription Part Code Initial

Lumen Life (Hrs) Temp Position QtyCM-PLUS TC20W/U/UVS/G8.5/830 00354 1800 9000 3000 k 80+ 90 Universal 12CM-PLUS TC20W/U/UVS/G8.5/942 00355 1800 9000 4200 k 90+ 90 Universal 12CM-PLUS TC35W/U/UVS/G8.5/830 00356 3400 12000 3000 k 80+ 97 Universal 12CM-PLUS TC35W/U/UVS/G8.5/942 00357 3300 12000 4200 k 90+ 94 Universal 12CM-PLUS TC70W/U/UVS/G8.5/830 00358 7000 12000 3000 k 80+ 100 Universal 12CM-PLUS TC70W/U/UVS/G8.5/942 00359 6600 12000 4200 k 90+ 94 Universal 12CM-PLUS T35W/U/UVS/G12/830 00362 3400 12000 3000 k 80+ 97 Universal 12CM-PLUS T35W/U/UVS/G12/942 00363 3300 12000 4200 k 90+ 94 Universal 12CM-PLUS T70W/U/UVS/G12/830 00364 7000 12000 3000 k 80+ 100 Universal 12CM-PLUS T70W/U/UVS/G12/942 00365 6600 12000 4200 k 90+ 94 Universal 12CM-PLUS T150W/U/UVS/G12/830 00368 15000 12000 3000 k 80+ 100 Universal 12CM-PLUS T150W/U/UVS/G12/942 00369 13500 12000 4200 k 90+ 90 Universal 12CM-PLUS TD70W/U/UVS/Rx7s/830 00370 7000 15000 3000 k 80+ 100 Universal 12CM-PLUS TD70W/U/UVS/Rx7s/942 00371 6600 15000 4200 k 90+ 94 Universal 12CM-PLUS TD150W/U/UVS/Rx7s/830 00372 14000 15000 3000 k 80+ 100 Universal 12CM-PLUS TD150W/U/UVS/Rx7s/942 00373 12500 15000 4200 k 90+ 83 Universal 12CM-PLUS TT70W/U/UVS/830 00374 7000 18000 3000 k 80+ 100 Universal 12CM-PLUS TT70W/U/UVS/942 00375 6600 18000 4200 k 90+ 94 Universal 12CM-PLUS TT150W/U/UVS/830 00378 14000 18000 3000 k 80+ 93 Universal 12CM-PLUS TT150W/U/UVS/942 00379 13500 18000 4200 k 90+ 90 Universal 12

Rated Color CRI LPW Burn Carton

Electronic BallastWattage Part Code Input Voltage Hz Dimensions ( L x W x H)

20 VYB020255 220-240 50-60 109 x 72 x 31 mm35 SH35 220-240 50-60 123 x 77 x 30.5 mm70 SH70GC 220-240 50-60 109 x 76 x 32 mm

150 SH150I 220-240 50-60 176 x 88 x 35.5 mm

Best in Class Color Rendering Index (CRI)Excellent Lumen MaintenanceExceptional Color Consistency & StabilityIncreased Lamp LifeIdeal for Quality Interior DecorsOptimal lamp control and operationEnd of lamp life protectionHigh efficient, low watt lossLess weight and compact

Features

Commercial LightingMH MR16

11

Shopping MallsTrack LightingShow Rooms

Retail LightingShowcase LightingAuto Dealership Showrooms

Applications

Features

Compared to quartz halogen, Venture’s track lighting systemSaving up to 64% energy without sacrificing light levelsup to 31/2 x the light levels4x the lifeHigh CRI lighting, 90+Daylight colour : 5000K CCT, colors of products are truer

Shopping MallsTrack LightingShow Rooms

Retail LightingShowcase LightingAuto Dealership Showrooms

Applications

Features

IR halogen directional light source offering:30% energy savings (37W compared to standard 50W)30% more light output (50W compared to standard 50W)Dichromic coated precision glass reflectorCover lens with UV blocking protectionGU5.3 base for easy replacement and solid connectionConsistent color over life

Description Part Code

Center BeamCandle Power

Beam Angle* Beam Type Rated Life

Hours CCT CRI Lamp Color

MPSE 35W/GX10/MR16/950/SP/WH 60621 19000cd 10 Spot 12000 5000k 90+ WhiteMPSE 35W/GX10/MR16/950/NFL/WH 60631 11200cd 18 Narrow Flood 12000 5000k 90+ WhiteMPSE 35W/GX10/MR16/950/FL/WH 60632 5100cd 30 Flood 12000 5000k 90+ White

Description Part Code

Center BeamCandle Power

Beam Angle* Beam Type Rated Life

Hours

HIR-M 37MR16/IR/FL9 28945 13000 9 Spot 5000HIR-M 37MR16/IR/FL25 35664 4400 25 Narrow Flood 5000HIR-M 37MR16/IR/FL35 55982 2200 35 Flood 5000HIR-M 37MR16/IR/FL60 76371 1100 60 Wide Flood 5000HIR-M 50MR16/IR/FL9 28955 15500 9 Spot 5000HIR-M 50MR16/IR/FL25 35674 5700 25 Narrow Flood 5000HIR-M 50MR16/IR/FL35 55992 2800 35 Flood 5000HIR-M 50MR16/IR/FL60 76381 1400 60 Wide Flood 5000

Commercial LightingHalogen MR16

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 13: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

Industrial LightingSodium Vapor Lamp

12 13

Street LightingWarehousesFlood LightingPeripheral Lighting

Applications

Higher EfficiencyMonochromatic LightFaster restriking Long life

Features

Description Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

PositionOperating

Current (A)Carton

Qty.Control

Gear

70W HPSV E D20011 5200 10000 2100 22 74 Universal 0.98 12 HPSV150W HPSV E D20013 12150 10000 2100 22 81 Universal 1.8 12 HPSV250W HPSV E D20014 22500 10000 2100 22 90 Universal 3.1 12 HPSV400W HPSV E D20016 42300 10000 2100 22 105.75 Universal 4.45 6 HPSV70W HPSV T D20010 5200 10000 2100 22 74 Universal 0.98 12 HPSV150W HPSV T D20012 12150 10000 2100 22 81 Universal 1.8 12 HPSV250W HPSV T D20015 22500 10000 2100 22 90 Universal 3.1 12 HPSV400W HPSV T D20017 42300 10000 2100 22 105.75 Universal 4.45 12 HPSV

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 14: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

Industrial LightingSodium Vapor Lamp

12 13

Street LightingWarehousesFlood LightingPeripheral Lighting

Applications

Higher EfficiencyMonochromatic LightFaster restriking Long life

Features

Description Part Code

Initial Lumens*

Avg. LifeHours*

Colour Temp. CRI LPW Burn

PositionOperating

Current (A)Carton

Qty.Control

Gear

70W HPSV E D20011 5200 10000 2100 22 74 Universal 0.98 12 HPSV150W HPSV E D20013 12150 10000 2100 22 81 Universal 1.8 12 HPSV250W HPSV E D20014 22500 10000 2100 22 90 Universal 3.1 12 HPSV400W HPSV E D20016 42300 10000 2100 22 105.75 Universal 4.45 6 HPSV70W HPSV T D20010 5200 10000 2100 22 74 Universal 0.98 12 HPSV150W HPSV T D20012 12150 10000 2100 22 81 Universal 1.8 12 HPSV250W HPSV T D20015 22500 10000 2100 22 90 Universal 3.1 12 HPSV400W HPSV T D20017 42300 10000 2100 22 105.75 Universal 4.45 12 HPSV

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 15: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

Class Ballast 'B’

Wattage Part no Lamp Type Nominal Lamp Current Dimension Rated Voltage (A) (LxWxH)

50 HSK052224 MH 220 / 240 0.76 104 x 69 x 5670 HSK072224 MH / SV 220 / 240 1 104 x 69 x 5680 MP082224 MH / MV 220 / 240 0.8 105 x 69 x 56100 HSK102224 MH 220 / 240 1.1 106 x 69 x 56125 MP027224 MH / SV 220 / 240 1.15 106 x 69 x 56150 HSK152224 MH / SV 220 / 240 1.8 140 x 69 x 59200 HMK202224 MH 220 / 240 1.6 135 x 68 x 56250 HSD252224U MH / SV 220 / 240 3 140 x 77 x 57250 HMD252224 MH / MV 220 / 240 2.15 123 x 77 x 64320 HMA322232 MH 230 / 240 2.63 167 x 85 x 72400 HSD402224U MH / SV 220 / 240 4.2 140 x 86 x 72400 HMD402224 MH / MV 220 / 240 3.25 140 x 77 x 57600 HSD602224 MH / SV 220 / 240 6.2 150 x 99 x 811000 HDP003212 MH / SV 210/220/230/240 10.3 190 x 120 x 1051500 HMV022383 MH 380/400/415 6.7 215 x 150 x 1262000 HZK944K384V2 MH 380/400/415/430 10.3 235 x 101 x 137

AccessoriesBallasts

14

Class 'H' Ballast

Wattage Part Code

Description InputVolts

Lamp Current

(A)

Dimension (LxWxH)

70 HSK072224H MH / SV 220 / 240 1 104 x 69 x 5680 MP082224H MH / MV 220 / 240 0.8 105 x 69 x 56125 MP027224H MH / MV 220 / 240 1.15 106 x 69 x 56150 HSK152224H MH / SV 220 / 240 1.8 140 x 69 x 59

Wattage Part Code

Lamp Type InputVolts

Lamp Current

(A)

Dimension (LxWxH)

35 IBU035D245i MH / SV 240 0.54 126 x 70 x 6070 IBU070245 MH / SV 240 1 175 x 78 x 68150 IBU150245 MH / SV 240 1.8 175 x 78 x 68250 IBU250D245i MH / SV 240 3 195 x 78 x 68250 IBM250245 MH / MV 240 2.15 180 x 93 x 76

Vaccum ImpregnatedPrecision Wound BallastHigher efficiencyReduced current crest factorLonger lifeOptimized lamp performanceAvailable with Thermal cut-outAvailable in all HID ranges

Features

Compact SizePrecision Wound BallastHigher efficiencyReduced current crest factorLonger lifeOptimized lamp performance

Features

Also available in Class H Insulation

Accessories

Accessories

Integrated Ballasts Unit

Ignitor

15

Part no Type Wattage Voltage Termination Dimension Pulse magnitude Capacitance (pf) Temp (*C)

BCLC47 Impulser 70 - 400W 240V Wire Dia 30 mm 3.8 - 4.5 KV 3000 85BC7040 Super Imposed 70 - 400W 240V Terminal Block Dia 39 mm 3.5 - 4.5 KV 100 105MC16 Semi Parallel 35 - 400W 240V Terminal Block 50 x 25 x 17 3 - 4.5 KV 1000 105PXE000255 Super Imposed 600 - 1000W 240V Terminal Block 90 x 49 x 50 3 - 5 KV 100 105PT150K445 Super Imposed 1000 - 2000W 440V Terminal Block Dia 51 mm 5 - 6 KV 200 90PBA200485 Two Wire 1000 - 2000 400V Terminal Block Dia 51 mm 1 - 1.5 KV 10000 85PXA100255 Super Imposed 35 - 150W 240V Terminal Block 78 x 39 x 36 3.5 - 4 KV 100 105PB404K225 Impulser 250 - 400W 240V Terminal Block Dia 39 mm 3 -4.5 KV 3000 85

Max Lead Max case

Compact DesignZero Watts Loss -and No Internal Temperature RiseA Longer ReachDigital Intelligence

Features

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 16: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

Class Ballast 'B’

Wattage Part no Lamp Type Nominal Lamp Current Dimension Rated Voltage (A) (LxWxH)

50 HSK052224 MH 220 / 240 0.76 104 x 69 x 5670 HSK072224 MH / SV 220 / 240 1 104 x 69 x 5680 MP082224 MH / MV 220 / 240 0.8 105 x 69 x 56100 HSK102224 MH 220 / 240 1.1 106 x 69 x 56125 MP027224 MH / SV 220 / 240 1.15 106 x 69 x 56150 HSK152224 MH / SV 220 / 240 1.8 140 x 69 x 59200 HMK202224 MH 220 / 240 1.6 135 x 68 x 56250 HSD252224U MH / SV 220 / 240 3 140 x 77 x 57250 HMD252224 MH / MV 220 / 240 2.15 123 x 77 x 64320 HMA322232 MH 230 / 240 2.63 167 x 85 x 72400 HSD402224U MH / SV 220 / 240 4.2 140 x 86 x 72400 HMD402224 MH / MV 220 / 240 3.25 140 x 77 x 57600 HSD602224 MH / SV 220 / 240 6.2 150 x 99 x 811000 HDP003212 MH / SV 210/220/230/240 10.3 190 x 120 x 1051500 HMV022383 MH 380/400/415 6.7 215 x 150 x 1262000 HZK944K384V2 MH 380/400/415/430 10.3 235 x 101 x 137

AccessoriesBallasts

14

Class 'H' Ballast

Wattage Part Code

Description InputVolts

Lamp Current

(A)

Dimension (LxWxH)

70 HSK072224H MH / SV 220 / 240 1 104 x 69 x 5680 MP082224H MH / MV 220 / 240 0.8 105 x 69 x 56125 MP027224H MH / MV 220 / 240 1.15 106 x 69 x 56150 HSK152224H MH / SV 220 / 240 1.8 140 x 69 x 59

Wattage Part Code

Lamp Type InputVolts

Lamp Current

(A)

Dimension (LxWxH)

35 IBU035D245i MH / SV 240 0.54 126 x 70 x 6070 IBU070245 MH / SV 240 1 175 x 78 x 68150 IBU150245 MH / SV 240 1.8 175 x 78 x 68250 IBU250D245i MH / SV 240 3 195 x 78 x 68250 IBM250245 MH / MV 240 2.15 180 x 93 x 76

Vaccum ImpregnatedPrecision Wound BallastHigher efficiencyReduced current crest factorLonger lifeOptimized lamp performanceAvailable with Thermal cut-outAvailable in all HID ranges

Features

Compact SizePrecision Wound BallastHigher efficiencyReduced current crest factorLonger lifeOptimized lamp performance

Features

Also available in Class H Insulation

Accessories

Accessories

Integrated Ballasts Unit

Ignitor

15

Part no Type Wattage Voltage Termination Dimension Pulse magnitude Capacitance (pf) Temp (*C)

BCLC47 Impulser 70 - 400W 240V Wire Dia 30 mm 3.8 - 4.5 KV 3000 85BC7040 Super Imposed 70 - 400W 240V Terminal Block Dia 39 mm 3.5 - 4.5 KV 100 105MC16 Semi Parallel 35 - 400W 240V Terminal Block 50 x 25 x 17 3 - 4.5 KV 1000 105PXE000255 Super Imposed 600 - 1000W 240V Terminal Block 90 x 49 x 50 3 - 5 KV 100 105PT150K445 Super Imposed 1000 - 2000W 440V Terminal Block Dia 51 mm 5 - 6 KV 200 90PBA200485 Two Wire 1000 - 2000 400V Terminal Block Dia 51 mm 1 - 1.5 KV 10000 85PXA100255 Super Imposed 35 - 150W 240V Terminal Block 78 x 39 x 36 3.5 - 4 KV 100 105PB404K225 Impulser 250 - 400W 240V Terminal Block Dia 39 mm 3 -4.5 KV 3000 85

Max Lead Max case

Compact DesignZero Watts Loss -and No Internal Temperature RiseA Longer ReachDigital Intelligence

Features

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 17: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

LuminairesLowbay

16

Railway PatformsStorage areasLoading bays

Parking / Sport hallsCargo

Applications

Electrochemically brightened and high purity anodized aluminum hammered finish reflector provides excellent light distribution

CRCA sheet housing, felt gasket, heat resistant & thoughened glass cover fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingStainless steel toggles & M.S. bracket for suspensionLamp holder base E-27 skirted porcelain Earthing terminal

Reflector

Construction

Part no Lamp Type Lamp Qty Wattage Nominal Rated VoltageVL/LB-50W MH 1 50 220 / 240

VL/LB-70W MH / SV 1 70 220 / 240

VL/LB-100W MH 1 100 220 / 240

VL/LB-150W MH / SV 1 150 220 / 240

17

Applications

Lowbay IndustrialStorage areasLoading bays

Parking / Sport hallsWarehouses

Electrochemically brightened and high purity anodized aluminum hammered finish reflector provides excellent light distribution

Reflector

CRCA sheet housing, heat resistant & thoughened glass cover fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingStainless steel toggles & M.S. bracket for suspensionLamp holder base E-27 skirted porcelain Earthing terminalRelamping from front sideRecess mounting suitable for false ceiling

Construction

Part no Lamp Type Qty Lamp Wattage Nominal Rated Voltage

VL/MBI-50W MH 1 50 220 / 240

VL/MBI-70W MH / SV 1 70 220 / 240

VL/MBI-100W MH 1 100 220 / 240

VL/MBI-150W MH / SV 1 150 220 / 240

LuminairesMediumbay

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 18: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

LuminairesLowbay

16

Railway PatformsStorage areasLoading bays

Parking / Sport hallsCargo

Applications

Electrochemically brightened and high purity anodized aluminum hammered finish reflector provides excellent light distribution

CRCA sheet housing, felt gasket, heat resistant & thoughened glass cover fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingStainless steel toggles & M.S. bracket for suspensionLamp holder base E-27 skirted porcelain Earthing terminal

Reflector

Construction

Part no Lamp Type Lamp Qty Wattage Nominal Rated VoltageVL/LB-50W MH 1 50 220 / 240

VL/LB-70W MH / SV 1 70 220 / 240

VL/LB-100W MH 1 100 220 / 240

VL/LB-150W MH / SV 1 150 220 / 240

17

Applications

Lowbay IndustrialStorage areasLoading bays

Parking / Sport hallsWarehouses

Electrochemically brightened and high purity anodized aluminum hammered finish reflector provides excellent light distribution

Reflector

CRCA sheet housing, heat resistant & thoughened glass cover fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingStainless steel toggles & M.S. bracket for suspensionLamp holder base E-27 skirted porcelain Earthing terminalRelamping from front sideRecess mounting suitable for false ceiling

Construction

Part no Lamp Type Qty Lamp Wattage Nominal Rated Voltage

VL/MBI-50W MH 1 50 220 / 240

VL/MBI-70W MH / SV 1 70 220 / 240

VL/MBI-100W MH 1 100 220 / 240

VL/MBI-150W MH / SV 1 150 220 / 240

LuminairesMediumbay

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 19: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

LuminairesHigh Bay

Die cast aluminium corrosion resistant housing, silicon rubber gasket, heat resistant & toughened glass cover fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal block.Epoxy powder coated paintingLamp holder base Rx7s with silver contacts (E-40), skirted porcelainEarthing terminal

Construction

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/CL-70W MH 1 70 220 / 240

VL/CL-150W MH / SV 1 150 220 / 240

VL/CL-200W MH 1 200 220 / 240

VL/CL-250W MH / SV 1 250 220 / 240

VL/CL-320W MH 1 320 220 / 240

VL/CL-400W MH / SV 1 400 220 / 240

18

LuminairesCanopy

Petrol pumpsIndustrial Bays

Applications

Electrochemically brightened and high purity anodized aluminum hammered finish reflector provides excellent light distribution

Reflector

Top mounted die cast aluminium corrosion resistant housing accommodating lamp holder, copper wound ballast, PF correction capacitor and electronic ignitor prewired upto terminal blockEpoxy Powder coated paintingM.S. eyebolt for mountingLamp holder base E-40 skirted porcelainEarthing terminal

Construction

19

Assembly shop AtriumLobbies

Aircrat hangersWarehouses

Applications

High efficient polycarbonate reflector provides excellent light distribution

Reflector

Part no Lamp Type Lamp Wattage Nominal RatedQty Voltage

VL/HBP/OR-150W MH / SV 1 150 220 / 240VL/HBP/OR-200W MH 1 200 220 / 240VL/HBP/OR-250W MH / MV 1 250 220 / 240VL/HBP/OR-320W MH 1 320 220 / 240VL/HBP/OR-400W MH / MV 1 400 220 / 240

Open Rated

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 20: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

LuminairesHigh Bay

Die cast aluminium corrosion resistant housing, silicon rubber gasket, heat resistant & toughened glass cover fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal block.Epoxy powder coated paintingLamp holder base Rx7s with silver contacts (E-40), skirted porcelainEarthing terminal

Construction

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/CL-70W MH 1 70 220 / 240

VL/CL-150W MH / SV 1 150 220 / 240

VL/CL-200W MH 1 200 220 / 240

VL/CL-250W MH / SV 1 250 220 / 240

VL/CL-320W MH 1 320 220 / 240

VL/CL-400W MH / SV 1 400 220 / 240

18

LuminairesCanopy

Petrol pumpsIndustrial Bays

Applications

Electrochemically brightened and high purity anodized aluminum hammered finish reflector provides excellent light distribution

Reflector

Top mounted die cast aluminium corrosion resistant housing accommodating lamp holder, copper wound ballast, PF correction capacitor and electronic ignitor prewired upto terminal blockEpoxy Powder coated paintingM.S. eyebolt for mountingLamp holder base E-40 skirted porcelainEarthing terminal

Construction

19

Assembly shop AtriumLobbies

Aircrat hangersWarehouses

Applications

High efficient polycarbonate reflector provides excellent light distribution

Reflector

Part no Lamp Type Lamp Wattage Nominal RatedQty Voltage

VL/HBP/OR-150W MH / SV 1 150 220 / 240VL/HBP/OR-200W MH 1 200 220 / 240VL/HBP/OR-250W MH / MV 1 250 220 / 240VL/HBP/OR-320W MH 1 320 220 / 240VL/HBP/OR-400W MH / MV 1 400 220 / 240

Open Rated

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 21: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

LuminairesTop Mounting High Bay

21

Open Rated Enclosed Rated

Part no Lamp Type Lamp Wattage Nominal RatedQty Voltage

VL/HBOR/TM-150W MH / MV 1 150 220 / 240VL/HBOR/TM-200W MH 1 200 220 / 240VL/HBOR/TM-250W MH / MV 1 250 220 / 240VL/HBOR/TM-320W MH 1 320 220 / 240VL/HBOR/TM-400W MH / MV 1 400 220 / 240

Part no Lamp Type Lamp Wattage Nominal RatedQty Voltage

VL/HBTE/TM-150W MH / MV 1 150 220 / 240VL/HBTE/TM-200W MH 1 200 220 / 240VL/HBTE/TM-250W MH / MV 1 250 220 / 240VL/HBTE/TM-320W MH 1 320 220 / 240VL/HBTE/TM-400W MH / MV 1 400 220 / 240

Steel plantsThermal power stationsWarehouses

IndustriesFertilizer plantsAircrat hangers

Applications

Electrochemically brightened and high purity anodized aluminum reflector provides excellent light distribution

Reflector

Top mounted die cast aluminium corrosion resistant housing accommodating lamp holder, copper wound ballast, PF correction capacitor and electronic ignitor prewired upto terminal blockEpoxy Powder coated paintingM.S. eyebolt for mountingLamp holder base E-40 skirted porcelainEarthing terminal

Construction

Open Rated Enclosed Rated

Part no Lamp Type Lamp Wattage Nominal RatedQty Voltage

VL/HBOR/SM-150W MH / SV 1 150 220 / 240VL/HBOR/SM-200W MH 1 200 220 / 240VL/HBOR/SM-250W MH / MV 1 250 220 / 240VL/HBOR/SM-320W MH 1 320 220 / 240VL/HBOR/SM-400W MH / MV 1 400 220 / 240

Part no Lamp Type Lamp Wattage Nominal RatedQty Voltage

VL/HBTE/SM-150W MH / SV 1 150 220 / 240VL/HBTE/SM-200W MH 1 200 220 / 240VL/HBTE/SM-250W MH / MV 1 250 220 / 240VL/HBTE/SM-320W MH 1 320 220 / 240VL/HBTE/SM-400W MH / MV 1 400 220 / 240

LuminairesHigh Bay

20

Steel plantsThermal power stationsWarehouses

IndustriesFertilizer plantsAircrat hangers

Applications

Electrochemically brightened and high purity anodized aluminum reflector provides excellent light distribution

Reflector

Side mounted die cast aluminium corrosion resistant housing accommodating lamp holder, copper wound ballast, PF correction capacitor and electronic ignitor prewired upto terminal blockEpoxy Powder coated paintingM.S. eyebolt for mountingLamp holder base E-40 skirted porcelainEarthing terminal

Construction

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 22: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

LuminairesTop Mounting High Bay

21

Open Rated Enclosed Rated

Part no Lamp Type Lamp Wattage Nominal RatedQty Voltage

VL/HBOR/TM-150W MH / MV 1 150 220 / 240VL/HBOR/TM-200W MH 1 200 220 / 240VL/HBOR/TM-250W MH / MV 1 250 220 / 240VL/HBOR/TM-320W MH 1 320 220 / 240VL/HBOR/TM-400W MH / MV 1 400 220 / 240

Part no Lamp Type Lamp Wattage Nominal RatedQty Voltage

VL/HBTE/TM-150W MH / MV 1 150 220 / 240VL/HBTE/TM-200W MH 1 200 220 / 240VL/HBTE/TM-250W MH / MV 1 250 220 / 240VL/HBTE/TM-320W MH 1 320 220 / 240VL/HBTE/TM-400W MH / MV 1 400 220 / 240

Steel plantsThermal power stationsWarehouses

IndustriesFertilizer plantsAircrat hangers

Applications

Electrochemically brightened and high purity anodized aluminum reflector provides excellent light distribution

Reflector

Top mounted die cast aluminium corrosion resistant housing accommodating lamp holder, copper wound ballast, PF correction capacitor and electronic ignitor prewired upto terminal blockEpoxy Powder coated paintingM.S. eyebolt for mountingLamp holder base E-40 skirted porcelainEarthing terminal

Construction

Open Rated Enclosed Rated

Part no Lamp Type Lamp Wattage Nominal RatedQty Voltage

VL/HBOR/SM-150W MH / SV 1 150 220 / 240VL/HBOR/SM-200W MH 1 200 220 / 240VL/HBOR/SM-250W MH / MV 1 250 220 / 240VL/HBOR/SM-320W MH 1 320 220 / 240VL/HBOR/SM-400W MH / MV 1 400 220 / 240

Part no Lamp Type Lamp Wattage Nominal RatedQty Voltage

VL/HBTE/SM-150W MH / SV 1 150 220 / 240VL/HBTE/SM-200W MH 1 200 220 / 240VL/HBTE/SM-250W MH / MV 1 250 220 / 240VL/HBTE/SM-320W MH 1 320 220 / 240VL/HBTE/SM-400W MH / MV 1 400 220 / 240

LuminairesHigh Bay

20

Steel plantsThermal power stationsWarehouses

IndustriesFertilizer plantsAircrat hangers

Applications

Electrochemically brightened and high purity anodized aluminum reflector provides excellent light distribution

Reflector

Side mounted die cast aluminium corrosion resistant housing accommodating lamp holder, copper wound ballast, PF correction capacitor and electronic ignitor prewired upto terminal blockEpoxy Powder coated paintingM.S. eyebolt for mountingLamp holder base E-40 skirted porcelainEarthing terminal

Construction

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 23: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

23

Power plantsSteel plantsFertilizer plantsRefineriesCable conveyor galleries

Applications

Electrochemically brightened and high purity anodized aluminum reflector provides excellent light distribution

Reflector

Pressure die cast aluminium corrosion resistant housing, heat resistant glass dome, wire guard fitted with copper wound ballast, PF correction capacitor and electronic ignitor prewired upto terminal blockEpoxy Powder coated paintingLamp holder base E40 Pin BC skirted porcelainEarthing terminalIP 65 protection

Construction

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/WG-150W MH / SV 1 150 220 / 240

LuminairesWell Glass

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/WG-50W MH 1 50 220 / 240VL/WG-70W MH / SV 1 70 220 / 240VL/WG-100W MH 1 100 220 / 240

LuminairesWell Glass

22

Power plantsSteel plantsFertilizer plantsRefineriesCable conveyor galleries

Applications

Electrochemically brightened and high purity anodized aluminum reflector provides excellent light distribution

Reflector

Pressure die cast aluminium corrosion resistant housing, heat resistant glass dome, wire guard fitted with copper wound ballast, PF correction capacitor and electronic ignitor prewired upto terminal blockEpoxy Powder coated paintingLamp holder base E27 skirted porcelainEarthing terminalIP 65 protection

Construction

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 24: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

23

Power plantsSteel plantsFertilizer plantsRefineriesCable conveyor galleries

Applications

Electrochemically brightened and high purity anodized aluminum reflector provides excellent light distribution

Reflector

Pressure die cast aluminium corrosion resistant housing, heat resistant glass dome, wire guard fitted with copper wound ballast, PF correction capacitor and electronic ignitor prewired upto terminal blockEpoxy Powder coated paintingLamp holder base E40 Pin BC skirted porcelainEarthing terminalIP 65 protection

Construction

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/WG-150W MH / SV 1 150 220 / 240

LuminairesWell Glass

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/WG-50W MH 1 50 220 / 240VL/WG-70W MH / SV 1 70 220 / 240VL/WG-100W MH 1 100 220 / 240

LuminairesWell Glass

22

Power plantsSteel plantsFertilizer plantsRefineriesCable conveyor galleries

Applications

Electrochemically brightened and high purity anodized aluminum reflector provides excellent light distribution

Reflector

Pressure die cast aluminium corrosion resistant housing, heat resistant glass dome, wire guard fitted with copper wound ballast, PF correction capacitor and electronic ignitor prewired upto terminal blockEpoxy Powder coated paintingLamp holder base E27 skirted porcelainEarthing terminalIP 65 protection

Construction

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 25: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

LuminairesStreet Light

25

LuminairesDownlight

24

Down lighterCorridorsShopping MallsRetail OutletsDisplay

Applications

Electrochemically brightened and high purity anodized aluminum reflector provides excellent light distribution

Spun aluminium reflectorG12 Lamp Holder BaseToughened glass coverSpring loaded bracketsUniform light distributionEasy to install & maintain

ReflectorConstruction

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/SL-50W MH 1 50 220 / 240

VL/SL-70W MH / SV 1 70 220 / 240

VL/SL-100W MH 1 100 220 / 240

Secondary roadsIndustrial areasResidential areasCar parks

HighwaysRoundaboutsRoad junctionSecurity lighting

Applications

Single piece die cast aluminium housing, long lasting felt gasket, acrylic bowl fitted with copper wound ballast, PF correction capacitor and electronic ignitor prewired upto terminal block Epoxy powder coated paintingStainless steel togglesLamp holder base E-27 skirted porcelainEarthing terminalIP 43 protection

Construction

Reflector

Electrochemically brightened and high purity anodized aluminium Pot optic reflector provide efficient light distributionPart no Lamp Type Lamp Qty Wattage

VL/DLG-001 MH 1 70/150VL/DLG-002 MH 2 70/150VL/DLG-003 MH 3 70/150

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 26: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

LuminairesStreet Light

25

LuminairesDownlight

24

Down lighterCorridorsShopping MallsRetail OutletsDisplay

Applications

Electrochemically brightened and high purity anodized aluminum reflector provides excellent light distribution

Spun aluminium reflectorG12 Lamp Holder BaseToughened glass coverSpring loaded bracketsUniform light distributionEasy to install & maintain

ReflectorConstruction

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/SL-50W MH 1 50 220 / 240

VL/SL-70W MH / SV 1 70 220 / 240

VL/SL-100W MH 1 100 220 / 240

Secondary roadsIndustrial areasResidential areasCar parks

HighwaysRoundaboutsRoad junctionSecurity lighting

Applications

Single piece die cast aluminium housing, long lasting felt gasket, acrylic bowl fitted with copper wound ballast, PF correction capacitor and electronic ignitor prewired upto terminal block Epoxy powder coated paintingStainless steel togglesLamp holder base E-27 skirted porcelainEarthing terminalIP 43 protection

Construction

Reflector

Electrochemically brightened and high purity anodized aluminium Pot optic reflector provide efficient light distributionPart no Lamp Type Lamp Qty Wattage

VL/DLG-001 MH 1 70/150VL/DLG-002 MH 2 70/150VL/DLG-003 MH 3 70/150

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 27: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

27

LuminairesStreet LightLuminairesStreet Light

26

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/SLG-50W MH 1 50 220 / 240VL/SLG-70W MH / SV 1 70 220 / 240VL/SLG-100W MH 1 100 220 / 240

Secondary roadsIndustrial areasResidential areasCar parks

HighwaysRoundaboutsRoad junctionSecurity lighting

Applications

Single piece die cast aluminium corrosion resistant housing, synthetic rubber gasket, heat resistant & toughened glass cover fitted with copper wound ballast, PF correction capacitor and electronic ignitorare prewired upto terminal blockEpoxy powder coated paintingStainless steel togglesLamp holder base E-27 skirted porcelainEarthing terminalIP 65 protection

Construction

Reflector

Electrochemically brightened and high purity anodized aluminium Pot optic reflector provide efficient light distribution

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/SL-150W MH / SV 1 100 220 / 240VL/SL-200W MH 1 100 220 / 240VL/SL-250W MH / SV 1 100 220 / 240

Electrochemically brightened and high purity anodized aluminium Pot optic reflector provide efficient light distribution

Reflector

HighwaysIndustrial areasCar parks

RoundaboutsRoad junctionSecurity lighting

Applications

Single piece die cast aluminium corrosion resistant housing, synthetic rubber gasket, heat resistant & toughened glass cover fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy powder coated patingStainless steel togglesLamp holder base E-40, skirted porcelainEarthing terminalIP 65 protection

Construction

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 28: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

27

LuminairesStreet LightLuminairesStreet Light

26

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/SLG-50W MH 1 50 220 / 240VL/SLG-70W MH / SV 1 70 220 / 240VL/SLG-100W MH 1 100 220 / 240

Secondary roadsIndustrial areasResidential areasCar parks

HighwaysRoundaboutsRoad junctionSecurity lighting

Applications

Single piece die cast aluminium corrosion resistant housing, synthetic rubber gasket, heat resistant & toughened glass cover fitted with copper wound ballast, PF correction capacitor and electronic ignitorare prewired upto terminal blockEpoxy powder coated paintingStainless steel togglesLamp holder base E-27 skirted porcelainEarthing terminalIP 65 protection

Construction

Reflector

Electrochemically brightened and high purity anodized aluminium Pot optic reflector provide efficient light distribution

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/SL-150W MH / SV 1 100 220 / 240VL/SL-200W MH 1 100 220 / 240VL/SL-250W MH / SV 1 100 220 / 240

Electrochemically brightened and high purity anodized aluminium Pot optic reflector provide efficient light distribution

Reflector

HighwaysIndustrial areasCar parks

RoundaboutsRoad junctionSecurity lighting

Applications

Single piece die cast aluminium corrosion resistant housing, synthetic rubber gasket, heat resistant & toughened glass cover fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy powder coated patingStainless steel togglesLamp holder base E-40, skirted porcelainEarthing terminalIP 65 protection

Construction

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 29: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

1729

LuminairesHoarding

Electrochemically brightened and high purity anodized aluminum hammered finish reflector provides excellent light distribution

Reflector

Construction sitesCoal yardsRailway marshalling yardsAirport aprons

Sports stadiumFacade lightingSecurity lightingSemihigh mast lighting

Applications

Die cast aluminium corrosion resistant housing, heat resistant silicon rubber gasket, high purity anodised aluminium reflector, heat resistant & toughened glass cover, mounting M.S. cradle fitted with copper would ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingStainless steel toggles & earthing terminalRelamping from front sideE40 holderIP 65 protection

Construction

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/HLT-200W MH 1 200 220 / 240

VL/HLT-250W MH / SV 1 250 220 / 240

VL/HLT-320W MH 1 320 220 / 240

VL/HLT-400W MH / SV 1 400 220 / 240

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/HLT-70W MH 1 70 220 / 240

VL/HLT-150W MH / SV 1 150 220 / 240

LuminairesHoarding

1628

Electrochemically brightened and high purity anodized aluminum hammered finish reflector provides excellent light distribution

Reflector

Construction sitesCoal yardsRailway marshalling yardsAirport aprons

Sports stadiumFacade lightingSecurity lightingSemihigh mast lighting

Applications

Die cast aluminium corrosion resistant housing, heat resistant silicon rubber gasket, high purity anodised aluminium reflector, heat resistant & toughened glass cover, mounting M.S. cradle fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingStainless steel toggles & earthing terminalRelamping from front sideRX 7s holder with silver contactsIP 65 protection

Construction

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 30: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

1729

LuminairesHoarding

Electrochemically brightened and high purity anodized aluminum hammered finish reflector provides excellent light distribution

Reflector

Construction sitesCoal yardsRailway marshalling yardsAirport aprons

Sports stadiumFacade lightingSecurity lightingSemihigh mast lighting

Applications

Die cast aluminium corrosion resistant housing, heat resistant silicon rubber gasket, high purity anodised aluminium reflector, heat resistant & toughened glass cover, mounting M.S. cradle fitted with copper would ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingStainless steel toggles & earthing terminalRelamping from front sideE40 holderIP 65 protection

Construction

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/HLT-200W MH 1 200 220 / 240

VL/HLT-250W MH / SV 1 250 220 / 240

VL/HLT-320W MH 1 320 220 / 240

VL/HLT-400W MH / SV 1 400 220 / 240

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/HLT-70W MH 1 70 220 / 240

VL/HLT-150W MH / SV 1 150 220 / 240

LuminairesHoarding

1628

Electrochemically brightened and high purity anodized aluminum hammered finish reflector provides excellent light distribution

Reflector

Construction sitesCoal yardsRailway marshalling yardsAirport aprons

Sports stadiumFacade lightingSecurity lightingSemihigh mast lighting

Applications

Die cast aluminium corrosion resistant housing, heat resistant silicon rubber gasket, high purity anodised aluminium reflector, heat resistant & toughened glass cover, mounting M.S. cradle fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingStainless steel toggles & earthing terminalRelamping from front sideRX 7s holder with silver contactsIP 65 protection

Construction

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 31: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

31

Construction sitesBuilding façadeLandscape

SecurityShopping areasParking areas

Applications

Electrochemically brightened and high purity anodized stippled aluminium reflector provides efficient light distribution

Reflector

Single piece die cast aluminium corrosion resistant housing & frame, high purity aluminium reflector, heat resistant & toughened glass, silicon rubber gasket and M.S. mounting bracketNon integral flood light with separate control gear Epoxy powder coated paintingLamp holder base Rx7s with silver contactsEarthing terminalLamp holders are prewired upto terminal blockIP 65 protection

Construction

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/AFL/NI-150W MH / SV 1 150 220 / 240

LuminairesFlood LightLuminairesFlood Light

Single piece die cast aluminium corrosion resistant housing & frame, high purity aluminium reflector, heat resistant & toughened glass, silicon rubber gasket and M.S. mounting bracketEpoxy powder coated paintingLamp holder base Rx7s with silver contactsEarthing terminalLamp holders are prewired upto terminal blockIP 65 protection

Construction

Part no Lamp Type Lamp Qty Wattage Nominal Rated VoltageVL/AFL-70W MH 1 150 220 / 240VL/AFL-150W MH 1 200 220 / 240

30

Building façadeConstruction sitesLandscape

Shopping areasSecurityParking areas

Applications

Electrochemically brightened and high purity anodized aluminium reflector provides efficient light distribution

Reflector

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 32: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

31

Construction sitesBuilding façadeLandscape

SecurityShopping areasParking areas

Applications

Electrochemically brightened and high purity anodized stippled aluminium reflector provides efficient light distribution

Reflector

Single piece die cast aluminium corrosion resistant housing & frame, high purity aluminium reflector, heat resistant & toughened glass, silicon rubber gasket and M.S. mounting bracketNon integral flood light with separate control gear Epoxy powder coated paintingLamp holder base Rx7s with silver contactsEarthing terminalLamp holders are prewired upto terminal blockIP 65 protection

Construction

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/AFL/NI-150W MH / SV 1 150 220 / 240

LuminairesFlood LightLuminairesFlood Light

Single piece die cast aluminium corrosion resistant housing & frame, high purity aluminium reflector, heat resistant & toughened glass, silicon rubber gasket and M.S. mounting bracketEpoxy powder coated paintingLamp holder base Rx7s with silver contactsEarthing terminalLamp holders are prewired upto terminal blockIP 65 protection

Construction

Part no Lamp Type Lamp Qty Wattage Nominal Rated VoltageVL/AFL-70W MH 1 150 220 / 240VL/AFL-150W MH 1 200 220 / 240

30

Building façadeConstruction sitesLandscape

Shopping areasSecurityParking areas

Applications

Electrochemically brightened and high purity anodized aluminium reflector provides efficient light distribution

Reflector

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 33: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

33

LuminairesFlood Light

Construction sitesCoal yardsRailway marshalling yardsAirport aprons

Sports stadiumsFacade lightingsecurity lightingsHigh mast lighting

Applications

Electrochemically brightened and high purity spun anodised aluminium parabolic reflector provides efficient light distribution

Reflector

Die cast aluminium corrosion resistant housing, heat resistant & toughended glass cover, synthetic rubber gasket with mounting M.S. cradleEpoxy powder coated paintingRelamping from front sideLamp holder base E-40 skirted porcelainEarthing terminalLamp holders are prewired upto terminal blockIP 65 protection

Construction

Part no Lamp Type* Lamp Qty Wattage Nominal Rated Voltage

VL/SFL/NI-150W MH / SV 1 150 220 / 240

VL/SFL/NI-200W MH 1 200 220 / 240

VL/SFL/NI-250W MH / SV 1 250 220 / 240

VL/SFL/NI-320W MH 1 320 220 / 240

VL/SFL/NI-400W MH / SV 1 400 220 / 240

Construction sitesCoal yardsRailway marshalling yardsAirport aprons

Sports stadiumsFacade lightingSecurity lightings

Applications

Electrochemically brightened and high purity anodised aluminium reflector provides efficient light distribution

Reflector

Die cast aluminium corrosion resistant housing, silicone rubber gasket, heat resistant & toughened glass cover with mounting M.S. cradleNon integral flood light with separate control gear Epoxy powder coated paintingRelamping from front sideLamp holder base E-40 skirted porcelainEarthing terminalLamp holders are prewired upto terminal blockIP 65 protection

Construction

Part no Lamp Type* Lamp Qty Wattage Nominal Rated Voltage

VL/AFL/NI-200W MH 1 200 220 / 240

VL/AFL/NI-250W MH / SV 1 250 220 / 240

VL/AFL/NI-320W MH 1 320 220 / 240

VL/AFL/NI-400W MH / SV 1 400 220 / 240

32

LuminairesFlood Light

* MH/MV configuration for 250 & 400 W is also available * MH/MV configuration for 250 & 400 W is also available

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 34: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

33

LuminairesFlood Light

Construction sitesCoal yardsRailway marshalling yardsAirport aprons

Sports stadiumsFacade lightingsecurity lightingsHigh mast lighting

Applications

Electrochemically brightened and high purity spun anodised aluminium parabolic reflector provides efficient light distribution

Reflector

Die cast aluminium corrosion resistant housing, heat resistant & toughended glass cover, synthetic rubber gasket with mounting M.S. cradleEpoxy powder coated paintingRelamping from front sideLamp holder base E-40 skirted porcelainEarthing terminalLamp holders are prewired upto terminal blockIP 65 protection

Construction

Part no Lamp Type* Lamp Qty Wattage Nominal Rated Voltage

VL/SFL/NI-150W MH / SV 1 150 220 / 240

VL/SFL/NI-200W MH 1 200 220 / 240

VL/SFL/NI-250W MH / SV 1 250 220 / 240

VL/SFL/NI-320W MH 1 320 220 / 240

VL/SFL/NI-400W MH / SV 1 400 220 / 240

Construction sitesCoal yardsRailway marshalling yardsAirport aprons

Sports stadiumsFacade lightingSecurity lightings

Applications

Electrochemically brightened and high purity anodised aluminium reflector provides efficient light distribution

Reflector

Die cast aluminium corrosion resistant housing, silicone rubber gasket, heat resistant & toughened glass cover with mounting M.S. cradleNon integral flood light with separate control gear Epoxy powder coated paintingRelamping from front sideLamp holder base E-40 skirted porcelainEarthing terminalLamp holders are prewired upto terminal blockIP 65 protection

Construction

Part no Lamp Type* Lamp Qty Wattage Nominal Rated Voltage

VL/AFL/NI-200W MH 1 200 220 / 240

VL/AFL/NI-250W MH / SV 1 250 220 / 240

VL/AFL/NI-320W MH 1 320 220 / 240

VL/AFL/NI-400W MH / SV 1 400 220 / 240

32

LuminairesFlood Light

* MH/MV configuration for 250 & 400 W is also available * MH/MV configuration for 250 & 400 W is also available

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 35: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

35

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/AFL/NI-1000W MH / SV 1 1000 220 / 240

LuminairesFlood Light

Construction sitesCoal yardsRailway marshalling yardsAirport aprons

Sports stadiumsFacade lightingSecurity lightingsHigh mast lighting

Applications

Electrochemically brightened and high purity anodised aluminium reflector provides efficient light distribution

Reflector

Die cast aluminium corrosion resistant housing, silicone rubber gasket, heat resistant & toughened glass cover with mounting M.S. cradleEpoxy powder coated paintingRelamping from front sideLamp holder base E-40 skirted porcelainStainless steel togglesEarthing terminalLamp holders are prewired upto terminal blockIP 65 protection

Construction

LuminairesFlood Light

34

Part no Lamp Type* Lamp Qty Wattage Nominal Rated Voltage

VL/AFL/NI-2X200W MH 2 200 220 / 240

VL/AFL/NI-2X250W MH / SV 2 250 220 / 240

VL/AFL/NI-2X320W MH 2 320 220 / 240

VL/AFL/NI-2X400W MH / SV 2 400 220 / 240

Construction sitesCoal yardsRailway marshalling yardsAirport aprons

Sports stadiumsFacade lightingSecurity lightingsHigh mast lighting

Applications

Electrochemically brightened and high purity anodised aluminium reflector provides efficient light distribution

Reflector

Die cast aluminium corrosion resistant housing, silicone rubber gasket, heat resistant & toughened glass cover with mounting M.S. cradleEpoxy powder coated paintingRelamping from front sideLamp holder base E-40 skirted porcelainStainless steel togglesEarthing terminalLamp holders are prewired upto terminal blockIP 65 protection

Construction

* MH/MV configuration for 250 & 400 W is also available

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 36: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

35

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/AFL/NI-1000W MH / SV 1 1000 220 / 240

LuminairesFlood Light

Construction sitesCoal yardsRailway marshalling yardsAirport aprons

Sports stadiumsFacade lightingSecurity lightingsHigh mast lighting

Applications

Electrochemically brightened and high purity anodised aluminium reflector provides efficient light distribution

Reflector

Die cast aluminium corrosion resistant housing, silicone rubber gasket, heat resistant & toughened glass cover with mounting M.S. cradleEpoxy powder coated paintingRelamping from front sideLamp holder base E-40 skirted porcelainStainless steel togglesEarthing terminalLamp holders are prewired upto terminal blockIP 65 protection

Construction

LuminairesFlood Light

34

Part no Lamp Type* Lamp Qty Wattage Nominal Rated Voltage

VL/AFL/NI-2X200W MH 2 200 220 / 240

VL/AFL/NI-2X250W MH / SV 2 250 220 / 240

VL/AFL/NI-2X320W MH 2 320 220 / 240

VL/AFL/NI-2X400W MH / SV 2 400 220 / 240

Construction sitesCoal yardsRailway marshalling yardsAirport aprons

Sports stadiumsFacade lightingSecurity lightingsHigh mast lighting

Applications

Electrochemically brightened and high purity anodised aluminium reflector provides efficient light distribution

Reflector

Die cast aluminium corrosion resistant housing, silicone rubber gasket, heat resistant & toughened glass cover with mounting M.S. cradleEpoxy powder coated paintingRelamping from front sideLamp holder base E-40 skirted porcelainStainless steel togglesEarthing terminalLamp holders are prewired upto terminal blockIP 65 protection

Construction

* MH/MV configuration for 250 & 400 W is also available

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 37: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

44

LuminairesLuminairesControl Gear BoxControl Gear Box

36

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/CGB-150W MH / SV 1 150 220 / 240

VL/CGB-250W MH / SV 1 250 220 / 240

VL/CGB-400W MH / SV 1 400 220 / 240

Non-integral flood lightsIndustrial luminaires

Applications

Pressure Die Cast aluminium corrosion resistant housing fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingSynthetic rubber gasketEarthing terminalPorcelain rewireable fuse cutoutIP 65 protection

Construction

4537

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/CGB-2X150W MH / SV 2 150 220 / 240

VL/CGB-2X250W MH / SV 2 250 220 / 240

VL/CGB-2X400W MH / SV 2 400 220 / 240

Non-integral flood lightsIndustrial luminaires

Applications

Cast aluminium corrosion resistant housing fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingSynthetic rubber gasketEarthing terminalPorcelain rewireable fuse cutoutIP 65 protection

Construction

LuminairesLuminairesControl Gear BoxControl Gear Box

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 38: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

44

LuminairesLuminairesControl Gear BoxControl Gear Box

36

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/CGB-150W MH / SV 1 150 220 / 240

VL/CGB-250W MH / SV 1 250 220 / 240

VL/CGB-400W MH / SV 1 400 220 / 240

Non-integral flood lightsIndustrial luminaires

Applications

Pressure Die Cast aluminium corrosion resistant housing fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingSynthetic rubber gasketEarthing terminalPorcelain rewireable fuse cutoutIP 65 protection

Construction

4537

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/CGB-2X150W MH / SV 2 150 220 / 240

VL/CGB-2X250W MH / SV 2 250 220 / 240

VL/CGB-2X400W MH / SV 2 400 220 / 240

Non-integral flood lightsIndustrial luminaires

Applications

Cast aluminium corrosion resistant housing fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingSynthetic rubber gasketEarthing terminalPorcelain rewireable fuse cutoutIP 65 protection

Construction

LuminairesLuminairesControl Gear BoxControl Gear Box

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 39: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

44

Cast aluminium corrosion resistant housing fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingHeat resistant EPR gasketPorcelain rewireable fuse cutoutIP 65 protection

Construction

LuminairesControl Gear Box

38

Non-integral flood lightsIndustrial luminaires

Applications

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/CGB-1000W MH / SV 1 1000 210 / 220 / 230 / 240

Glossary of Terms

4539

Arc Tube: A completely sealed quartz or ceramic tube where the electrical discharge (arc) occurs and generates light

Ballast: A device that, by means of resistance, inductance, capacitance or electronic elements, singly or in combination, controls the current, voltage and waveform to the required values for proper lamp starting and operation for a HID ballast operating at a given supply voltage

Ballast Factor: Typically associated with fluorescent systems; metal halide ballasts are designed to operate lamps at rated watts, whereas some fluorescent systems are designed to operate at a fraction of rated watts

Burning Position: The position in which lamps are designed to operate

Cold Start Time: The amount of time from the application of ballast voltage to ignition of the arc discharge

Colour Rendering Index (Ra): A measure of a light source's ability to render colours relative to a standard

Constant Wattage Autotransformer (CWA)Control Gear: An autotransformer lead ballast circuit incorporating a capacitor in series with the lamp; compared to other ballasts, the CWA regulates over a wider input voltage range, holding lamp wattage to a narrow range by controlling lamp current

Correlated Colour Temperature (CCT): The perceived “colour” of the light emitted by a lamp expressed in Kelvin (K units)

Current Crest Factor: The ratio of the peak to the rms value of lamp current; metal halide values range from 1.5 to 1.8

Economic Life: The number of hours a group of lamps will burn before it is economically and aesthetically advisable to group relamp (typically 60% to 75% of rated life)

Efficacy (Lamp): A ratio of lumens to watts; often calculated with either lamp watts or system watts; measured in lumens per watt (LPW)

Formed Body Arc Tube: Precisely reproducible ellipsoidal arc tube formed by Venture's quartz sculpting process; has 2/3 less quartz mass than standard arc tubes for equivalent lumens; has no starter electrode

HID: High Intensity Discharge lamps; includes metal halide, mercury vapor and high pressure sodium

Hot Restart or Restrike Time: The amount of time from return of power after an interruption to the point of lamp ignition

Ignitor: An electronic device which provides, by itself or in combination with other circuit components, the appropriate electrical conditions to start a discharge lamp

Initial Lumens: The light output of a lamp, based on photometry results, at rated wattage after 100 hours of operation Input Voltage at Lamp Dropout

Input Watts: The power measured on the input terminals of a ballast which is operating a reference lamp

Lag Ballast: A ballast exhibiting primarily inductive electrical characteristics, including a lagging lamp current with respect to line voltage and lagging or corrected line power factor.

Lamp Voltage: The voltage at which lamps operate when they are fully warmed up

Lamp Wattage: The power consumed by a lamp after warm-up

Light Center Length (LCL): The distance from the center of the arc discharge to the end contact of the base

Lumens: A measurement of light output; takes into account the human eye sensitivity curve so that more weight is given to the yellow-green part of the light spectrum

Lumen Maintenance: The lumen output provided by a lamp at a given point in or percentage of its life

Lumens Per Watt (LPW): A ratio of lumens to watts; often calculated with either lamp watts or system watts; measured in lumens per watt (LPW)

Luminaire Requirements: The type of luminaire a lamp requires; i.e., enclosed or open rated

Maximum Overall Length (MOL): The maximum allowable distance from the top of the glass bulb to the end contact of the base

Open Circuit Current (Line): The RMS current measured through the input terminals of a ballast with lamp removed or inoperative

Open Rated Lamp (E27): Designed for open luminaires; has a narrower neck than standard E27 base lamps. Lamp arc tube is surrounded by a protective quartz shroud.

Open Rated Lamp (E40): Designed for open luminaires. Lamp arc tube is surrounded by a protective quartz shroud.

Operating Current (Line): The power factor corrected current measured through the input terminals of a ballast which is operating a reference lamp

Operating Voltage: The voltage at which lamps operate when they are fully warmed up

Power Factor (Ballast): The ratio of the ballast input power (watts) divided by the product of the RMS ballast supply voltage and ballast supply current

Probe Start Lamp: A metal halide lamp which uses a starter electrode (probe) to assist in starting instead of an ignitor pulse; also contains a bimetal switch and resistor

Pulse Start Lamp : Specially designed metal halide lamp that requires a high voltage pulse for starting; has no starter electrode (probe).

Quad-tap Ballast: A magnetic lag ballast with input voltage taps for four standard voltages – 12, 208, 240 and 277 volts

Rated Life: The number of operating hours at which 50% of the lamps will still be operating

Rated Supply Voltage: The input voltage for which a ballast in designed to operate, and to which performance characteristics are referred

Restrike: To re-ignite the acr of an HID lamp

RMS: root-means-square

S/P Ratio: The ratio of Photopic lumens to scotopic lumens.

Scotopic Light: Applicable during dark nighttime lighting conditions; describes lumen values measured using the low luminance eye sensitivity function centered at 507 nm (blue-green)

Short-Circuit Current (Ballast): The current at the output terminals of a ballast when the output is shorted (RMS, unless otherwise stated)

Shroud: A Quartz cylinder surrounding the arc tube of a Venture open-rated (ANSI Type-O) metal halide lamp; designed to reduce the damage to the outer bulb if an arc tube ruptures occurs; required to pass the ANSI Type-O containment test

Starting Pulse: A high-voltage, low-energy pulse superimposed on the open circuit voltage of some HID ballast to aid in starting a lamp

Sustaining Voltage: The instantaneous voltage available to the lamp from the ballast at the time the lamp current passes through zero

System Power: The power measured at the input terminals of ballast while operating a reference lamp

Type-E Lamps (Enclosed Rated Lamps) : Lamps that must be used in enclosed luminaires which meet the requirements of UL1598

Type-S Lamps: Lamps that do not contain a shroud around the arc tube yet are considered “suitable” for open luminaire operation, only if operated in the vertical +15* position. They do not meet ANSI criteria for containment and must be turned off at least once power week for a minimum of 15 minutes if operated continuously; These lamps must be replaced at or before reaching rated lamp life; not recommended by the NEC or UL1598 for open luminaires

Type-O Lamps (Open rated lamps) Lamps that can be operating in either open or enclosed luminaires and do not need a weekly shut-off; meet the NSI criteria for containment-rated operation; special exclusionary sockets are available for those lamps to ensure that the wrong lamp type is not used

Uni-Form® : Venture's pulse start lamp that contains a formed body arc tube; requires a high voltage pulse for starting; has improved lumen maintenance and life.

Warm-up Time : The amount of time from ignition of the lamp to 90% of full light output

White-Lux®: Venture's line of retrofit metal halide lamps that operate on high pressure sodium ballasts

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 40: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

44

Cast aluminium corrosion resistant housing fitted with copper wound ballast, PF correction capacitor and electronic ignitor are prewired upto terminal blockEpoxy Powder coated paintingHeat resistant EPR gasketPorcelain rewireable fuse cutoutIP 65 protection

Construction

LuminairesControl Gear Box

38

Non-integral flood lightsIndustrial luminaires

Applications

Part no Lamp Type Lamp Qty Wattage Nominal Rated Voltage

VL/CGB-1000W MH / SV 1 1000 210 / 220 / 230 / 240

Glossary of Terms

4539

Arc Tube: A completely sealed quartz or ceramic tube where the electrical discharge (arc) occurs and generates light

Ballast: A device that, by means of resistance, inductance, capacitance or electronic elements, singly or in combination, controls the current, voltage and waveform to the required values for proper lamp starting and operation for a HID ballast operating at a given supply voltage

Ballast Factor: Typically associated with fluorescent systems; metal halide ballasts are designed to operate lamps at rated watts, whereas some fluorescent systems are designed to operate at a fraction of rated watts

Burning Position: The position in which lamps are designed to operate

Cold Start Time: The amount of time from the application of ballast voltage to ignition of the arc discharge

Colour Rendering Index (Ra): A measure of a light source's ability to render colours relative to a standard

Constant Wattage Autotransformer (CWA)Control Gear: An autotransformer lead ballast circuit incorporating a capacitor in series with the lamp; compared to other ballasts, the CWA regulates over a wider input voltage range, holding lamp wattage to a narrow range by controlling lamp current

Correlated Colour Temperature (CCT): The perceived “colour” of the light emitted by a lamp expressed in Kelvin (K units)

Current Crest Factor: The ratio of the peak to the rms value of lamp current; metal halide values range from 1.5 to 1.8

Economic Life: The number of hours a group of lamps will burn before it is economically and aesthetically advisable to group relamp (typically 60% to 75% of rated life)

Efficacy (Lamp): A ratio of lumens to watts; often calculated with either lamp watts or system watts; measured in lumens per watt (LPW)

Formed Body Arc Tube: Precisely reproducible ellipsoidal arc tube formed by Venture's quartz sculpting process; has 2/3 less quartz mass than standard arc tubes for equivalent lumens; has no starter electrode

HID: High Intensity Discharge lamps; includes metal halide, mercury vapor and high pressure sodium

Hot Restart or Restrike Time: The amount of time from return of power after an interruption to the point of lamp ignition

Ignitor: An electronic device which provides, by itself or in combination with other circuit components, the appropriate electrical conditions to start a discharge lamp

Initial Lumens: The light output of a lamp, based on photometry results, at rated wattage after 100 hours of operation Input Voltage at Lamp Dropout

Input Watts: The power measured on the input terminals of a ballast which is operating a reference lamp

Lag Ballast: A ballast exhibiting primarily inductive electrical characteristics, including a lagging lamp current with respect to line voltage and lagging or corrected line power factor.

Lamp Voltage: The voltage at which lamps operate when they are fully warmed up

Lamp Wattage: The power consumed by a lamp after warm-up

Light Center Length (LCL): The distance from the center of the arc discharge to the end contact of the base

Lumens: A measurement of light output; takes into account the human eye sensitivity curve so that more weight is given to the yellow-green part of the light spectrum

Lumen Maintenance: The lumen output provided by a lamp at a given point in or percentage of its life

Lumens Per Watt (LPW): A ratio of lumens to watts; often calculated with either lamp watts or system watts; measured in lumens per watt (LPW)

Luminaire Requirements: The type of luminaire a lamp requires; i.e., enclosed or open rated

Maximum Overall Length (MOL): The maximum allowable distance from the top of the glass bulb to the end contact of the base

Open Circuit Current (Line): The RMS current measured through the input terminals of a ballast with lamp removed or inoperative

Open Rated Lamp (E27): Designed for open luminaires; has a narrower neck than standard E27 base lamps. Lamp arc tube is surrounded by a protective quartz shroud.

Open Rated Lamp (E40): Designed for open luminaires. Lamp arc tube is surrounded by a protective quartz shroud.

Operating Current (Line): The power factor corrected current measured through the input terminals of a ballast which is operating a reference lamp

Operating Voltage: The voltage at which lamps operate when they are fully warmed up

Power Factor (Ballast): The ratio of the ballast input power (watts) divided by the product of the RMS ballast supply voltage and ballast supply current

Probe Start Lamp: A metal halide lamp which uses a starter electrode (probe) to assist in starting instead of an ignitor pulse; also contains a bimetal switch and resistor

Pulse Start Lamp : Specially designed metal halide lamp that requires a high voltage pulse for starting; has no starter electrode (probe).

Quad-tap Ballast: A magnetic lag ballast with input voltage taps for four standard voltages – 12, 208, 240 and 277 volts

Rated Life: The number of operating hours at which 50% of the lamps will still be operating

Rated Supply Voltage: The input voltage for which a ballast in designed to operate, and to which performance characteristics are referred

Restrike: To re-ignite the acr of an HID lamp

RMS: root-means-square

S/P Ratio: The ratio of Photopic lumens to scotopic lumens.

Scotopic Light: Applicable during dark nighttime lighting conditions; describes lumen values measured using the low luminance eye sensitivity function centered at 507 nm (blue-green)

Short-Circuit Current (Ballast): The current at the output terminals of a ballast when the output is shorted (RMS, unless otherwise stated)

Shroud: A Quartz cylinder surrounding the arc tube of a Venture open-rated (ANSI Type-O) metal halide lamp; designed to reduce the damage to the outer bulb if an arc tube ruptures occurs; required to pass the ANSI Type-O containment test

Starting Pulse: A high-voltage, low-energy pulse superimposed on the open circuit voltage of some HID ballast to aid in starting a lamp

Sustaining Voltage: The instantaneous voltage available to the lamp from the ballast at the time the lamp current passes through zero

System Power: The power measured at the input terminals of ballast while operating a reference lamp

Type-E Lamps (Enclosed Rated Lamps) : Lamps that must be used in enclosed luminaires which meet the requirements of UL1598

Type-S Lamps: Lamps that do not contain a shroud around the arc tube yet are considered “suitable” for open luminaire operation, only if operated in the vertical +15* position. They do not meet ANSI criteria for containment and must be turned off at least once power week for a minimum of 15 minutes if operated continuously; These lamps must be replaced at or before reaching rated lamp life; not recommended by the NEC or UL1598 for open luminaires

Type-O Lamps (Open rated lamps) Lamps that can be operating in either open or enclosed luminaires and do not need a weekly shut-off; meet the NSI criteria for containment-rated operation; special exclusionary sockets are available for those lamps to ensure that the wrong lamp type is not used

Uni-Form® : Venture's pulse start lamp that contains a formed body arc tube; requires a high voltage pulse for starting; has improved lumen maintenance and life.

Warm-up Time : The amount of time from ignition of the lamp to 90% of full light output

White-Lux®: Venture's line of retrofit metal halide lamps that operate on high pressure sodium ballasts

PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor

Page 41: PDF compression, OCR, web optimization using a watermarked ... Metal Halide Catalogue... · Venture Lighting India Ltd. - MEPZ, Chennai 1 Introduction Venture Lighting India Limited

LAMP WILL NOT START

CORRECTIVE ACTION

1. No Power to Ballast Check fuses or other causes of power outages.

2. Normal End of Lamp Life Often the simplest procedure is to test the lamp in an adjacent fixture which is known to be operating properly and then replace as necessary. It should be kept in mind that series ballasts will occasionally extinguish the adjacent lamp if one is removed.

3. Lamp Loose in Socket Inspect the lamp to see if there is any indication of arcing at center contact button. Tighten lamp to seat it properly. If base is distorted and will not seat properly in the socket, replace lamp.

4. Optical & Other Sensing Devices Inoperative Replace sensing device. (Check this by covering sensing device to block out light while power is applied to fixture.)

5. Defective or Improper Wiring Examine wiring to ensure it conforms with wiring diagram on the ballast label. Check primary wiring to ballast and from ballast to socket to establish circuit continuity. Check connections to see that they are secure. Check for under-sizing of wire gauge, resulting in lowered voltage. Repair circuit.

6. Voltage at Fixture Too Low Measure line voltage at input of ballast. For most types of ballasts, measured line voltage should be within 10% of label rating. With many types of distribution systems, increased loading or demand decreases available voltage at the ballast primary. Therefore, ideally, a check should be made at full load. If tapped ballast, match ballast tap connection to supply voltage measured at ballast. Increase supply voltage if feasible. Verify that lamp to remote ballast distance is acceptable.

7. Incompatible Ballasting Correct ballasting is essential for dependable HID lamp operation. Any HID lamp will perform erratically or fail to start on an incorrect ballast. Make sure that the ballast label data agrees with the line voltage and lamp used. Incorrect ballasting will generally cause a lamp to fail prematurely.

8. Defective Shorted Ballast A shorted ballast will generally cause the seals at the end of the arc tube to rupture with an indicative blackening in the seal ring area. Shorted condition may be due to shorted capacitors, shorted leads or shorted winding. Replace components as required.

9. Improper Lamp Operating Position The operating position should agree with the lamp specifications. A BU-HOR lamp can (Metal Halide Only) be operated base up, vertical to, and including the horizontal, and BD can be operated

base down, vertical to, approaching, but not including the horizontal. A lamp operated beyond the specified position may not start and degrade lamp performance if it does start.

10. Lamp Has Been Operating : When HID lamps are operating and the supply voltage is cut or interrupted, the lamps will require a period of time to cool and re-establish optimum starting conditions. Bare mercury and metal halide lamps require from four to eight minutes cool down time. High pressure sodium lamps require approximately one minute to cool before restriking. In a luminaire, restart time varies with the degree of ventilation built into it, ambient temperature, and draft conditions. The time from cool to restartable condition can realistically range up to 20 minutes for mercury and metal halide lamps in tight luminaires.

11. High Restrike Voltage (Metal Halide Only) This condition is peculiar to the metal halide lamp. It does not occur with mercury. If the Cool Down Time Insufficient (Hot Restrike) supply voltage to a metal halide lamp is interrupted during the warm up period, the

subsequent restrike voltage (voltage required to restart the lamp) may be higher than that required for a lamp which has been allowed to stabilize (come up to full output normally) or to cool down to normal room temperature.

12. Improper Ballast for Lamp Environmental conditions such as extreme temperatures, high humidity and other factors Operating Conditions affect ballast operation. Check lamp environmental operating conditions against

published performance.

13. End of Ballast Life The appearance or condition of a ballast may give a clue to whether it is good or not. If it is charred, it may have been subjected to sustained excessive heat. Swollen capacitors indicate trouble. Check with appropriate testers, ammeter, and voltmeter. Frequently, the failure mode of a ballast is capacitor failure with consequent low power factor operation and high current. This leads to overheating of the core and coil and eventual failure.

14. Defective Ignitor Insure that the lamp is good. Disconnect the ignitor and install a specified test lamp. If the test lamp lights, the ballast is good but the ignitor is not. Replace ignitor. If the test lamp does not light, the ballast has most likely reached its end of life.

15. Mismatched Ignitor Verify that the ballast and ignitor are matched according to the specifications. Replace if necessary.

16. Lamp Defects Common defects that require the lamp to be replaced include:· Arc tube leak · Open welds · Probe or cathode moly electrolysis · Diode or switch shorted · Quartz devitrification around rod · Sodium leak · Open diode

POSSIBLE CAUSE

4540PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor


Recommended