33
Albatross Projects GmbH Presentation for IEEE HK EMC Society Date: 24 th November 2012 Jeffrey Tsang
Transcript
Page 1: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Albatross Projects GmbH

Presentation for IEEE HK EMC Society

Date: 24th November 2012

Jeffrey Tsang

Page 2: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Company Introduction

Page 3: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite 3

Albatross Projects GmbH

1989 1999

Head Quarter – Germany

3 Major Business Areas:

● Tempest

● Medical Shield Room

● Anechoic Chambers

196X

Page 4: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite 4

Albatross Projects GmbH

3m chamber

Page 5: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite 5

Albatross Projects GmbH

10m Vehicle Chamber:

Page 6: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite 6

Albatross Projects GmbH

Special Design Anechoic Chambers:

Page 7: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite 7

Albatross Projects GmbH

Special Design Anechoic Chambers:

Page 8: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Introduction of EMC Testing for High Voltage

Component in Hybrid and Electric Vehicle

10

Page 9: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Today Technology

● Vehicle with combustion engine

● Hybrid Electric Vehicle

● Plug-in Hybrid Electric Vehicle

● Electric Vehicle

11

High voltage system:

• Battery - Can be up to 800Vdc

• Inverter: DC/AC, DC/DC

• Electric Motor: AC or DC

Reference : BOSCH Automotive Technology

Page 10: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Today Technology

12

Page 11: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Drive Mode

13

Starter/Alternator/

Electric Motor

Internal

Combustion Engine

Transmission

“Power Assist”

Recuperation Electrical Drive

Reference : Teseq Beijing EMC Exhibition Beijing 2009

Page 12: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Layout of Hybrid Vehicle

14

Page 13: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

High Voltage System

15

Reference : EE TIMES Automotive

October 06, 2010 | Frank Forster | 222901126

Page 14: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Full Vehicle Test Vs Components Test

16

Cost breakdown Comparison VEHICLE - COMPONENTS

Test [unit factor]

Time [unit factor]

Engineer & Labor [unit factor]

Vehicle testing 1 5 - 10 3 - 5

Component testing 0.3 - 0.5 1 1 - 2

Page 15: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Test Flow

17

● Automotive R&D Process on EMC componets

● EMC test for a full vehicle is extremely difficuly for trouble-shooting

● Must more cost effective and efficieny to start testing in componet level

A-Sample B-Sample C-Sample SOP

Entire timeframe: 2 – 3 years of R&D

Vehicle test

R&D start

Page 16: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

High Voltage System in Hybrid/Electric Vehicle

18

● Basic Model

– The EMC requirements on hybrid-, electric and even fuel cell power trains are in

general similarto each other.

High-voltage battery or fuel cell with complementary DC/DC converter

Low-voltage vehicle

electronics

Auxiliary Power Train

Page 17: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Common EMC Problems in HV system

● High DC voltage is converted into 3-phase AC voltage with variable

frequency

● This conversion process causes with high electro-magnetic field

strengths over a broad frequency range

● The noise is particularly high in the LF-, MF- and HF bands and can

also disturb the VHF bands

● Due to higher voltages, the noise level may increase up to 50x

compared to conventional vehicle electronics

19

Page 18: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Common EMC Problems of Automotive Component

Testing on HV system

20

● Interference level on the traction leads, example

Page 19: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Common EMC Problems of Automotive Component

Testing on HV system

21

● Interference level on a motor phase line

Page 20: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Common EMC Problems of Automotive Component

Testing on HV system

22

● Pulses in the High-voltage Traction- and Phase Network

– Example for disturbance pulse in the Traction network

Page 21: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Common EMC Problems of Automotive Component

Testing on HV system

23

Data buses

Auxiliary devices

Vehicle electronics

Signals

● Coupling between HV and LV

Page 22: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Common EMC Problems of Automotive Component

Testing on HV system

24

● Coupling between HV und LV

– The components show

Sterical electro-magnetic coupling (components inside the same

housing)

Functional coupling (data buses, functional links, power supply 12 V)

Page 23: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Technical Challenges on Testing

● For the normal 12V/24V components, there are many EMC standards

with clear technical guideline to follows, such as CISPR25, ISO11452,

OEM standards .. etc

● These existing standards/guidelines are still applicable for testing HV

components (Battery, Inverter, Motor ..) but not enough.

25

Page 24: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Technical Challenges on Testing

● High current and voltage may cause the following difficulties:

Large and expensive components (coils, capacitors)

Extensive weight

Requirement of larger space

Safety

26

Page 25: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Technical Challenges on Testing

● Test setup

– Whole setup is done in shielded anechoic chamber

– Shall be able to simulate the operation of EUT under different Drive

Mode: Drive, Brake, Recuperation

– Variable test RPM

– Mechanical stability of motor oscillations

– Cooling system for test sample

27

Page 26: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Test Setup in Chamber (CISPR25 ed.3)

28

The guideline in existing CISPR25 ed.3 is not good enough for testing HV

components

Page 27: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Suggested Test Setup in Chamber

with HV Inverter and Motor

29

1. Standard power supply

2. Shielded power supply

3. EUT

4. Shielded load simulator

5. Standard load simulator

6. Standard supply line

7. Shielded supply line

8. Low relative permittivity support

(εr<1,4) thickness 50mm

9. High quality coaxial cable e.g. double

shielded (50Ω)

10. Bulkhead connector

11. Lead through filter

12. Measuring instrument

13. Stimulation and monitoring system

14. Standard artificial network

15. Shielded artificial network

16. 50Ω load

17. Optical fibre

18. Shielded box

19. Biconical antenna

20. Ground plane

21. Electric motor

22. Brake or propulsion motor

Page 28: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Test Setup in Chamber

30

Reference: Mooser EMC Technik GmbH

Page 29: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Technical Challenges on Testing

31

Motor under test in

chamber Motor (Dynamometer) for

simulating road condition,

braking … etc

Shielding

Solid Support

for motor

stability Solid Support /

Test Bed for

stability

RF Absorbing

Material

Shaft

Page 30: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Technical Challenges on Testing

32

Chamber Inside Chamber Outside

● Maintaining the shielding effectiveness

● Maintaining the Anechoic Chamber RF performance

● Insulating the noise penetration from connection shaft

● Reinforcing the stability of chamber under motor vibration

Page 31: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Technical Challenges on Testing

33

● Energy System

Page 32: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite

Summary

● The major components of a high voltage system in Hybrid /Electric Vehicle: Battery,

Inverter, Electric Motor

● The noise level in high voltage system can be very high. This noise can be coupled to the

low voltage system

● The test setup for these major components is far more complicated because you need to

setup the load that can support different drive mode

● Additional instruments are required such as Energy System (DC power supply), Load

Simulator (Dynamometer)

● Special version of Anechoic Chamber for supporting the high voltage operation,

connection of Load Simulator and extra structural stability

34

Page 33: Albatross Projects GmbH - Department of EE - City …emc/20121124P2.pdfSeite 3 Albatross Projects GmbH 1989 1999 Head Quarter – Germany 3 Major Business Areas: Tempest Medical Shield

Seite 35

Special thanks to the technical contribution from

Mooser EMC Technik GmbH / Mooser Consulting GmbH

Thank You


Recommended