PDMS COMMANDS PIPING COMMANDS: 1. ADD ALL PIP 2. REM ALL PIP 3. MOVE U THROU IDP@ 4. MOVE E THROU IDP@ 5. MOVE W THROU IDP@ 6. MOVE N THROU IDP@ 7. MOVE S THROU IDP@ 8. Q DTXR (To See Name Of Component) 9. Q STEXT 10. STEXT ‘ NOTE (Naming For Attachment) 11. Q ATT (To see the attributes) 12. REPR INSU ON/OFF UPDATE 13. Q ISPEC (To see the insulation) 14. ISPEC NULREF (To Remove the Insulation) 15. CONN NEXT (Connection to next element) 16. FCONN (For force connection) 17. DIST 500 18. AXES AT PH (To see Axes of Pipe Head) 19. AXES AT PT (To see Axes of Pipe Tail) 20. AXES OFF 21. BY U 500 22. BY D 500 23. BY E 500 24. BY W 500 25. BY S 500 26. BY N 500 27. Q NAME 28. ROTATE BY 45 (Rotated command) 29. ROT BY 90 ABOUT Z THRO ID@ (Rotated) 30. Q PARA (To check nozzle size) 31. Q CATREF (To See nozzle Rating) 32. Q POS IN WORLD 33. CH CE (check current element) 34. Q SPREF (check piping Spec) 35. Q ORI (To see the orientation) 36. DIR D (Direction Down) U E W N S (For elbow, tee, valve)
Transcript
Page 1: pdms commands

PDMS COMMANDSPIPING COMMANDS:

1. ADD ALL PIP

2. REM ALL PIP

3. MOVE U THROU IDP@

4. MOVE E THROU IDP@

5. MOVE W THROU IDP@

6. MOVE N THROU IDP@

7. MOVE S THROU IDP@

8. Q DTXR  (To See Name Of Component)

9. Q STEXT

10. STEXT ‘NOTE’  (Naming For Attachment)

11. Q ATT  (To see the attributes)

12. REPR INSU ON/OFF UPDATE

13. Q ISPEC (To see the insulation)

14. ISPEC NULREF (To Remove the Insulation)

15. CONN NEXT (Connection to next element)

16. FCONN (For force connection)

17. DIST 500

18. AXES AT PH (To see Axes of Pipe Head)

19. AXES AT PT (To see Axes of Pipe Tail)

20. AXES OFF

21. BY U 500

22. BY D 500

23. BY E 500

24. BY W 500

25. BY S 500

26. BY N 500

27. Q NAME

28. ROTATE BY 45 (Rotated command)

29. ROT BY 90 ABOUT Z THRO ID@  (Rotated)

30. Q PARA (To check nozzle size)

31. Q CATREF (To See nozzle Rating)

32. Q POS IN WORLD

33. CH CE  (check current element)

34. Q SPREF (check piping Spec)

35. Q ORI (To see the orientation)

36. DIR D (Direction Down) U E W N S (For elbow, tee, valve)

37. Q P1/P2/P3 (To see pipe Bore Direction Connection type and Position)

Page 2: pdms commands

38. Q HBORE

39. Q TBORE

40. Q LBORE

41. NEW BRA COPY PREV BY E/W/S/N/U/D 100

42. Q U (To see the elevation)

43. Q ANGLE (For change the angle)

44. THRO NEXT (To connect element to next component)

45. Q LTLE (To cheek pipe length)

46. Q MEM

47. Q RTEX OF DETREF (To see element type and detail)

48. CONN IDP@ TO IDP Q CE

49. Q PL (For Direction and position)

50. BRA CONN PH TO FIST MEM

51. BRA CONN PT TO NOZZ ID@

52. BRA CONN PT TO LAST

53. RAD 500 (Control Valve Radius)

54. HEI 500  (Control Valve Height)

55. BACK (Backward)

56. FORW (Forward)

57. For Drain pipe

a. ADD ATT (For isometric note)

b. Q ATT

c. TCONN OPEN

d. Q STEXT

e. STEXT ‘DRAIN POINT’

58. For Slope Line /Rotated Elbow

a. FORWARDS (Select in piping components)

b. DIR TOW NEXT

c. BACKWARDS (Select in piping components)

d. DIR TOW NEXT

59. MTOC DOTD  (Do not want in bill of material) You can see the Doted DOTD

60. MTOC ON (Want in bill of material)

61. MTOC OFF (Don’t Want in bill of material)

62. Q PA BOP/TOP (To see the pipe BOP/TOP)

63. Q LSTUBE  (To Change the spec Brake)

64. Q PSPEC (To see the pipe spec)

65. CONN PH TO P3 OF ID@ ( AND SELECT THE PIPE P3)

66. CONN PT TO LAS MEM

Page 3: pdms commands

STRUCTURE COMMANDS.

1. AXES AT POSE/S (end or start)

2. Q POSE WRT/*

3. EXTE END BY D 500 WRT/*

4. EXTE START BY U 500 WRT/*

5. EXTE END/START THRO ID@

6. EXTE END/START THRO IDPL@  (PL-Pline)

7. Q CUTL (To see length of section)

8. Q POS PPLINE BOS IN/* (BOS TOS NA)

9. ADD ALL STR

10. REM ALL STR

11. Q ATT

12. BY U//D/E/W/N/S 500

13. Q DRNS DRNE

14. DRNSTART S 45 E (Direction and angle)

15. DRNEND S 45 W (Direction and angle)

EQUIPMENT COMMANDS.ADD ALL EQUI1. REM ALL EQUI

2. MOVE U THROU IDP@

3. MOVE E THROU IDP@

4. MOVE W THROU IDP@

5. MOVE N THROU IDP@

6. MOVE S THROU IDP@

7. REPR HOLES ON/OFF UPDATE

8. REPR OBST ON/OFF UPDATE

9. To Copy New Equipment

a. VAR1 NAME

b. NEW EQU COPY $V1 (To Include Equipment in another zone)

10. BY U//D/E/W/N/S 500

11. NEW BOX COPY PRE

12. NEW BOX XLEN 400 YLEN 250 ZLN 150

13. NEW CYL COPY PRE

14. NEW PYRE COPY PRE

15. NEW NOZZ COPY PRE

16. NEW BOX COPY PRE ROT BY 90 ABOUT Z THRO IDP@

Page 4: pdms commands

 

OTHERS COMMAND.

1. For copy equip/sub equipment from one project to another project.

a. FILE /FILE NAME.TXT

b. OUTPUT CE

c. TERM

2. For pest equipment / sub equipment from one project to another project.

a.       $M FILE NAME.TXT  

3.       EXPLANT (Type as it is)

a. repre level 6

b. repre level 6

c. repre level pipe 6

d. repre level stru 6

e. repre level nozz 6

f. EXPORT SYSTEM /explant

g. Export file /c:\export10 (file name)

ADD SITEh. export/ civil side colour 13

i. export/ equi side colour 15

j. export/ stru side colour 16

k. export finish

4. For Undo Command

a. MDB NOUPDATE

b. EXIT

5. Mdb Update

a. MDB UPDATE

b. USER PROMQAMQA/MQA

c. /SUFN

d. EXIT

6. UNCLAIM CE

7. UNCLAIM ALL

8. ALPHA REQ CLEAR  (To clear the command screen)

9. CREATE NEW ZONE/SITE/EQUI

10. ADD ALL WITHIN VOL CE 100

11. Q ORI (To see the orientation)

Page 5: pdms commands

12. ALPHA LOG /C:/ANANT.TXT (To make command line file)

ALFA LOG END13. SAVEWORK

14. Q US (User name)

15. Q MDB (Multiple data base)

16. Q REF

17. RECREATE DISPLAY /ABC.TXT  (For save Display)

18. $M ABC.TXT (For restore Display)

19. Q UNITS

20. Q DISPLAY

21. Q BANNER (To Check the version number)

22. Q BANNER FULL

23. Q TEAM (PDMS user name)

24. Q USER (Logging name)

25. Q DBNAME (To check DB name)

26. Q DBTYPE

27. Q DBFNUMBER

28. Q DBFILE

29. Q LASTMOD

30. Q SESSMOD

31. Q SESSMODI

32. Q USERMODI

33. Q LASTMODI HIER

34. Q DRAW

35. Q DRAW COUNT

36. Q DRAW FULL

37. STATUS

38. SYSTAT (Gives you information about the current active Status of the project)

39. recre disp /gggg over  (U can save as a display or u can do like this)

$m gggg

40.  FILE /C:/AAA OVER 

OUTPUT NEW CEV

TERM ENTER

$M /C:/AAA

Page 6: pdms commands

PDMS COMMANDS 

PIPING COMMANDS 

1. ADD ALL PIP 

2. REM ALL PIP

3. MOVE U THROU IDP@ 

4. MOVE E THROU IDP@ 

5. MOVE W THROU IDP@ 

6. MOVE N THROU IDP@ 

7. MOVE S THROU IDP@ 

8. Q DTXR (To See Name Of Component) 

9. Q STEXT 

10. STEXT ‘NOTE’ (Naming For Attachment) 

11. Q ATT (To see the attributes) 

12. REPR INSU ON/OFF UPDATE 

13. Q ISPEC (To see the insulation) 

14. ISPEC NULREF (To Remove the Insulation) 

15. CONN NEXT (Connection to next element) 

Page 7: pdms commands

16. FCONN (For force connection) 

17. DIST 500 

18. AXES AT PH (To see Axes of Pipe Head) 

19. AXES AT PT (To see Axes of Pipe Tail) 

20. AXES OFF 

21. BY U 500 

22. BY D 500 

23. BY E 500 

24. BY W 500 

25. BY S 500 

26. BY N 500 

27. Q NAME 

28. ROTATE BY 45 (Rotated command) 

29. ROT BY 90 ABOUT Z THRO ID@ (Rotated) 

30. Q PARA (To check nozzle size) 

31. Q CATREF (To See nozzle Rating) 

32. Q POS IN WORLD 

Page 8: pdms commands

33. CH CE (check current element) 

34. Q SPREF (check piping Spec) 

35. Q ORI (To see the orientation) 

36. DIR D (Direction Down) U E W N S (For elbow, tee, valve) 

37. Q P1/P2/P3 (To see pipe Bore Direction Connection type and Position) 

38. Q HBORE 

39. Q TBORE 

40. Q LBORE 

41. NEW BRA COPY PREV BY E/W/S/N/U/D 100 

42. Q U (To see the elevation) 

43. Q ANGLE (For change the angle) 

44. THRO NEXT (To connect element to next component) 

45. Q LTLE (To cheek pipe length) 

46. Q MEM 

47. Q RTEX OF DETREF (To see element type and detail) 

48. CONN IDP@ TO IDP Q CE 

49. Q PL (For Direction and position) 

50. BRA CONN PH TO FIST MEM 

51. BRA CONN PT TO NOZZ ID@ 

52. BRA CONN PT TO LAST 

53. RAD 500 (Control Valve Radius) 

54. HEI 500 (Control Valve Height) 

55. BACK (Backward) 

Page 9: pdms commands

56. FORW (Forward) 

57. For Drain pipe 

a. ADD ATT (For isometric note) 

b. Q ATT 

c. TCONN OPEN 

d. Q STEXT 

e. STEXT ‘DRAIN POINT’ 

58. For Slope Line /Rotated Elbow 

a. FORWARDS (Select in piping components) 

b. DIR TOW NEXT 

c. BACKWARDS (Select in piping components) 

d. DIR TOW NEXT 

59. MTOC DOTD (Do not want in bill of material) You can see the Doted DOTD 

60. MTOC ON (Want in bill of material) 

61. MTOC OFF (Don’t Want in bill of material) 

62. Q PA BOP/TOP (To see the pipe BOP/TOP) 

63. Q LSTUBE (To Change the spec Brake) 

64. Q PSPEC (To see the pipe spec) 

65. CONN PH TO P3 OF ID@ ( AND SELECT THE PIPE P3) 

66. CONN PT TO LAS MEM 

Page 10: pdms commands

PDMS Commands (Piping)

DELETE BRAN - Delete BranchQ HSTU - To Display Branch Head Side Tube AttributesQ LSTU - To Display Component Leave Side Tube AttributesQ ABORE - To Display Arrive Bore Of A ComponentQ LBORE - To Display Leave Side Bore Of A ComponentADD HREF TREF - Add Head & Tail ReferenceQ HBORE - To Display The Head Side Bore Of A BranchQ TBORE - To Display The Tail Side Bore Of A BranchQ SPRE - To Display The Specification Of The ComponentQ PSPEC - To Display The Specification Of The PipeNEW ELBO CHOO - Create New ElboNEW ELBO SEL WITH STYP EA - To Create The Elbo With Specific Selection TypeAXES AT HPOS - Axes At Head Possition Of The BranchAXES AT TPOS - Axes At Tail Possition Of The BranchNEX TUBI - Asking For Tube Being On The ComponentQ ITLE - To Display The Length Of The Tube Between Two ComponentsQ HREF - To Display The Head Reference Of A BranchQ TREF - To Display The Tail Reference Of A BranchQ DIR - To Display The Direction Of The Selected ComponentCONN PH TO FIR MEM - Connect Branch Head To The First Member Of The BranchCONN PT TO LAS MEM - Connect The Branch Tail To The Last Member Of The BranchQ ORI - To Display The Orientation Of Selected ComponentDIST - Giving The Distance Between Two Component CentersCLEA (SPOOL) - Giving The Spool Distance Between Two ComponentsQ CATREF - To Display The Catalogue Reference At Component LevelCONN - ConnectFCONN - Force ConnectQ STYP - To Display The Component Selection TypeQ DTXR - To Display The Detail Text(Description Of The ComponentDRAG BY E 1000 - Strech The Component By East 1000 (Not Prefered)Q MTXX - To Display The Material Of The ComponentQ MODE - To Display The Mode Of Direction (For/Back)FOR - To Set The Forward ModeBACK - To Set The Backward ModeFIRST MEM - To Navigate The First Member

Page 11: pdms commands

LAST MEM - To Navigate The Last MemberFIRST FLAN - To Navigate The First Flange In HierarchyQ PARA - To Display The ParametersQ ACONN - To Display The Arrive Connection Detail Of A ComponentQ LCONN - To Display The Leave Connection Details Of A ComponentDIR TOW NEX - Direction Towards The Next ComponentQ REF - To Display ReferenceINCL - IncludeORI AND P3 IS UP - Orient P3 Of Tee To Up (Specified Direction)OWN - Navigate OwnerGOTO OWN - Go To Owner Of The Selected ComponentQ ABOP/LBOP - Details Of The Arrive/Leave Boptom Of PipeQ ANGLE - Details Of A Angle Of An ElboQ ATLE - Length Of First Tube Of A BranchATTYPE CCNN - Comment Attachment Without DimensionATTYPE CCCC - Comment Attachment With DimensionATTYPE XXXX - Atta For Setting The Isometric LimitCH CE - Check Current Element (For Consistency Check)DIR TOW NEXT ELBO - Align A Elbo With The Next ElboDIR TOW ID@ - Align The ElbowEXTEND 100 START/END - Extend By 100 The Start/End Of A Cross MemberQ HCON/TCON - Details Of Head/Tail Connection Of A BranchQ HDIR - Direction Of The Flow From The Branch HeadQ HPOS/TPOS - Details Of Head/Tail Possition Of A BranchQ ISPE - Insulation SpecificationISPEC NULREF - For Removing InsulationSPKBRK T - For Removing Insulation (Use In Case Fof Atta)LOOSE - Used By Isodraft Where The Flange Is Supplied LooseMTOC DOTD - Mto Component Dotted With DimensionMTOC DOTU - Mto Component Dotted With Out DimensionMTOC OFF - Mto Component OffNEX CONN - Next ConnectNEX THRO CE - Move The Current Componet To NextORI AND P3 IS TOW ID@ & DIR TOW ID@ - Aligning The 3Rd P-Point Of A Tee Towards Next ElbowQ P3 - Details Of P-Point P3 (In Case Of Tee Only)Q PA/P1 - Details Of The P-Point 1Q PL - Derails Of The P-Point 2STEXT 'TEXT' - Setting The Comment TextTCONN OPEN - Tail Connection Type Open (Ce Should Be Branch)TDIR - Direction Of The Flow From The Branch TailISPEC /W - To Give The Insulation Q LBORE - To Query Leave Bore

Page 12: pdms commands

Q TBORE - To Query The Tail BoreTHRO PH - Through Pipe HeadTHRO PREV - Through PreviousTHRO PT - Through Pipe TailQ TPOS - To Query Tail PositionQ HCON - To Query The Head ConnectionQ TCON - To Query The Tail ConnectionQ ACON - To Query Arrive ConnectionQ LCON - To Query Leave ConnectionATTYPE FLOW - To Create Flow Direction Of AttachmentDIR N - Direction Of Component Towards NorthBACK CONN - Backward ConnectionMTOC UNSET - To Freeze The Component From Mto Report


Recommended