    Product Catalogue

    Intelligent PDUs

  • 7/25/2019 Pdu Mini Catalogo

    2/16

    Reduce energy costs:

    Identify high power consumption

    equipment by using logs and port

    monitoring

    Find opportunities for consolidation

    of underutilised equipment such as

    near-idle servers

    Use environmental monitoring to

    identify overcooling situations where

    temperatures could be increased for

    energy cost reduction

    Manage and optimise power

    capacity:

    Use real-time remote monitoring to

    understand usage vs. capacity andmake informed decisions on

    equipment additions and data centre

    changes

    Evaluate actual usage versus

    design assumptions (using equipment

    nameplate ratings) to understand truepower needs which may help increase

    equipment densities

    Spot and prevent potential

    problems to ensure uptime:

    Use alarms to quickly identify

    problems and drive resolution sooner

    Set alarm thresholds to spot

    potential problems such as overloads

    that could lead to power loss and

    downtime

    Use logs to identify erratic power

    consumption

    Use environmental monitoring to

    evaluate planned vs. actual

    temperatures to identify areas with

    insufficient cooling

    Efficiently control power functionsand resolve problems quickly:

    Use individual outlet control to

    remotely restart equipment or shut

    down specific units

    Use sequencing to safely start upor shut down equipment and avoid

    creating demand spikes

    Benets of

    Intelligent PDUs

  • 7/25/2019 Pdu Mini Catalogo

    3/16

  • 7/25/2019 Pdu Mini Catalogo

    4/16

    Siemons line of intelligent PDUs

    provide valuable energy

    consumption data while reliably

    delivering power to critical IT

    equipment. Each of our PDU

    families deliver real-time power

    information with varying degrees

    of intelligent functionality rangingfrom basic Metered units to

    full-featured Managed PDUs -

    providing multiple options based

    on the level of data and control

    requirements.

    Siemons intelligent PDUs may beused as stand-alone units, or they

    can communicate with third-party

    software through common open

    networking protocols.

    All of our network-capable intelligent

    PDUs also have the capacity to

    connect environmental sensors,

    allowing temperature, airflow, and

    humidity to be measured to further

    troubleshoot and optimise data centre

    efficiency.

    PDU Families

    Metered

    Monitored

    Smart

    Switched

    Managed

    Intelligent PDUs

    FUNCTION

    Built-In Display for Local Use

    Device-Level Monitoring

    Remote Monitoring via Ethernet Port

    Environmental Sensor Ports

    Locking Outlets

    Outlet-Level MonitoringOutlet-Level Switching/Control

    METERED

    P

    P

    MONITORED

    P

    P

    P

    P

    SMART

    P

    P

    P

    P

    P

    P

  • 7/25/2019 Pdu Mini Catalogo

    5/16

    Configurations

    Various plug inputs

    Single and 3-phase voltages

    Horizontal and zero-U vertical styles

    3m (10 ft.) cords (other lengths available

    on requests)

    Test data included with each unit

    SWITCHED

    P

    P

    P

    P

    P

    P

    MANAGED

    P

    P

    P

    P

    P

    P

    P

  • 7/25/2019 Pdu Mini Catalogo

    6/16

    Units have environmental monitoring

    capabilities through two RJ12 ports

    to support two separately purchased

    sensors directly, or up to 16 sensorsconnected via splitters

    Metered PDUs provides local visualmonitoring capability through a

    built-in LED meter that displays

    real-time consumption data.

    Metered PDUs are a cost-effective

    alternative to monitored or switched

    PDUs when remote monitoring is not

    desired, while providing a more

    intelligent alternative to basic PDUs.

    Metered PDUs The 3 phase and 60A units measurecurrent (amps) that scrolls through

    each phase

    Single-phase PDUs measure power

    by scrolling through power factor,

    amps, volts and watts

    Alarm conditions with high or low

    thresholds with notifications via buzzer,

    email, or SNMP trap

  • 7/25/2019 Pdu Mini Catalogo

    7/16

    Remote monitoring is established

    via an RJ45 port for network

    connection. Data can be

    downloaded in PDA, XML andSNMP formats

    The LCD display provides the ability

    to view power data locally. The

    display is customizable for data

    type, unit of measure and uniquedevice naming

  • 7/25/2019 Pdu Mini Catalogo

    8/16

    Monitored and Smart PDUs enable

    remote monitoring of power

    consumption.

    Smart PDUs

    Smart PDUs offer the highest level of

    monitioring by providing outlet-level

    data collection.

    Monitored PDUs

    Monitored PDUs collect data at an

    aggregate, device- level, generating a

    smaller quantity of information to

    simplify management.

    Monitored

    and Smart PDUs

    Units have environmental monitoring

    capabilities through two RJ12 ports

    to support two separately purchasedsensors directly, or up to 16 sensors

    connected via splitters

  • 7/25/2019 Pdu Mini Catalogo

    9/16

    Remote monitoring is establishedvia an RJ45 port for network

    connection. Data can be downloaded

    in PDA, XML and SNMP formats

    The LCD display provides the

    ability to view power data locally.

    The display is customizable fordata type, unit of measure and

    unique device naming

  • 7/25/2019 Pdu Mini Catalogo

    10/16

    Switched and

    Managed PDUsIn addition to power monitoring,

    switched and managed PDUs

    enable users to remotely control

    individual receptacles by

    allowing equipment to berestarted or remotely shut down.

    Switched PDUs

    Switched PDUs combine total PDU

    power monitoring with port-level

    switching. They are the ideal

    solution when port control isneeded but only aggregate

    consumption data is desired.

    Managed PDUs

    Managed PDUs offer the highest

    level of control and monitoring by

    providing outlet-level monitoring

    and outlet-level switching.

  • 7/25/2019 Pdu Mini Catalogo

    11/16

    The LCD display provides the ability to

    view power data locally. The display is

    customizable for data type, unit of

    measure and unique device naming.

    User definable URL for each outlet.

    Units have environmental monitoring

    capabilities through two RJ12 ports to

    support two separately purchasedsensors directly, or up to 16 sensors

    connected via splitters.

    Remote monitoring is established via

    an RJ45 port for network connection.

    Data can be downloaded in PDA, XML

    and SNMP formats.

  • 7/25/2019 Pdu Mini Catalogo

    12/16

    IntelligentPDU

    Software IntroductionThe Intelligent PDUs browser-based softwarecan be accessed through the use of the units

    individual IP address.

    This can be utilised remotely to access charts, logs,

    and alarms and directly interface with the unit toconfigure and define settings, including high or low

    thresholds for notifications via buzzer, email, or

    SNMP trap. Data can be downloaded in PDA, XML

    and SNMP formats.

    Scan Here to watch Siemons

    full software introduction videoor visit: www.siemon.com/ipdu

  • 7/25/2019 Pdu Mini Catalogo

    13/16

    Sequential start up

    and shut down to

    manage loads.

    The browser-basedinterface is used to

    access charts, logs,

    and alarms.

    Sensors Page -Delta Configuration.

  • 7/25/2019 Pdu Mini Catalogo

    14/16

    Specications

    General

    Safety Compliance

    Emissions

    Cord Length

    Circuit breakers

    Outlet Color Coding

    Material

    Finish

    Warranty

    Environmental

    Operating Temperature

    Storage Temperature

    Operating Humidity

    Storage Humidity

    Operating Elevation

    Storage Elevation

    Networking

    Networking Protocols

    Ethernet Link Speed

    Data Formats

    CE (International PDUs only)

    FCC Part 15 Class A

    3m (10 ft.)

    30A and higher units

    On 3 phase units for load balancing

    18 Gauge Steel

    Black powder coat

    3 Years

    -10C to 40C (50 to 104F)

    -25C to 65C (-13 to 149F)

    5% to 95% (non-condensing)

    5% to 95% (non-condensing)

    0 to 2000m (0 to 6561ft)

    0 to 15240m (0 to 50000ft)

    (not applicable to metered units)

    HTTP, HTTPS (SSL/TLS), SMTP, POP3, ICMP,

    DHCP, TCP/IP, NTP, Telnet, Syslog

    10 Mbit; half-duplex

    HTML, SNMP, CSV/Plain Text, XML

  • 7/25/2019 Pdu Mini Catalogo

    15/16

    Mounting

    Vertical PDUs mount via tooless

    button attachments and include a

    mounting bracket for additional flexibility

    Horizontal PDUs mount to standard

    EIA 19 in. configurations

    7ENS-TEMPTemperature Sensor

    7ENS-TEMPHAFTemp/ Airflow/ Humidity Sensor

    7ENA-SPLIT-5Splitter RJ12 x 5 way

    7ENS-WKITWater Sensor Cable

    7ENS-WATERWater Sensor

    AccessoriesA range of accessories have beendeveloped to support the

    application of the Intelligent PDU

    solution into varying

    environments, each designed

    to measure specific sets of datasuch as: humidity, presence of

    water, temperature and variations

    in airflow.

    Mounting

    Vertical PDUs mount via tooless

    button attachments and include a

    mounting bracket for additional flexibility

    Horizontal PDUs mount to standard

    EIA 19 in. configurations