Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 1 of 9 Pega 357 with 04PC Control Layout Drawings Amada America Inc. 7025 Firestone Blvd. Buena Park CA. 90621 Phone: (714) 739 2111 Fax: (714) 739 4099 Email [email protected]
Transcript
Page 1: Pega 357 with 04PC Control Layout Drawings - Used · PDF filePega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Print Date 03/02/2001 Revision 4.0 This document available

Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc.

Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 1 of 9

Pega 357 with 04PC Control Layout Drawings

Amada America Inc.7025 Firestone Blvd.

Buena Park CA. 90621Phone: (714) 739 2111

Fax: (714) 739 4099Email [email protected]

Page 2: Pega 357 with 04PC Control Layout Drawings - Used · PDF filePega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Print Date 03/02/2001 Revision 4.0 This document available

Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc.

Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 2 of 9

Warning! Qualified personnel must complete all work.

! Do not apply power to the Pega 357 until an A.E.S.I. (Amada Engineering andService Incorporated) Engineer is present and has instructed you to do so.

! Not all information required for proper installation, of the Pega 357 is included withthis document. Specific details for proper installation are found in the documentPega 357 with 04PC User Pre-installation Guide available at the Amada AmericaInternet web site at http://www.amada.com.

! Considerable effort has been made to ensure that this manual is free ofinaccuracies and omissions. However, as we are constantly improving ourproduct, some of the data contained herein may be out of date. Please check ourInternet site, http://www.amada.com, for the latest release of this document.

Page 3: Pega 357 with 04PC Control Layout Drawings - Used · PDF filePega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Print Date 03/02/2001 Revision 4.0 This document available

Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc.

Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 3 of 9

Table Of Contents

Planning the Location of the Machine ..............................................................................................................................................4

Plan View - Pega 357.......................................................................................................................................................................5

Plan View - Pega 357 with V357hs Conveyor..................................................................................................................................6

Plan View - Pega 357 with V357hs Conveyor and MP1225 Loader ................................................................................................7

End View - Pega 357 .......................................................................................................................................................................8

Elevation View - Pega 357 ...............................................................................................................................................................9

Page 4: Pega 357 with 04PC Control Layout Drawings - Used · PDF filePega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Print Date 03/02/2001 Revision 4.0 This document available

Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc.

Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 4 of 9

Planning the Location of the MachineThe following diagrams provide the details for positioning your new machine.

! Not all information required for proper installation, of the Pega 357 is included with this document. Specific details forproper installation are found in the document Pega 357 with 04PC User Pre-installation Guide available at the AmadaAmerica Internet web site at http://www.amada.com.

! No obstacles are allowed in the worksheet travel area and the ceiling must be at least 40" above the Pega 357.

! All of the Recommended Safety / Maintenance areas should be used, but you must at least ensure that the doors of the04PC control unit can be opened. Any reduction of the Recommended Safety / Maintenance areas may increase thepossibility of personnel injury and increase the time and cost of installation or maintenance.

! The Pega 357 and 04PC control must be protected from direct sunlight or other heat sources. Exposure to direct heatingsources such as infrared heaters have been shown to affect punch and die alignment.

Page 5: Pega 357 with 04PC Control Layout Drawings - Used · PDF filePega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Print Date 03/02/2001 Revision 4.0 This document available

Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc.

Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 5 of 9

Plan View - Pega 357

Optional Material Support Tables Required

Optional Material Support Tables Required

288.00" Maximum travel area 144" material

Electrical Requirements

Pega 357230 / 460 / 3 / 60 ±10% 18 kVA46 amps @ 230 / 3 / 60 VAC23 amps @ 460 / 3 / 60 VAC

Pega 357

Compressed Air Requirements

80 psi @ 2.9 ft³/min.

Indicates Operator Control Station

E1

E1

A1

A1

12" 12" 12"

Scale

PEGA 357

Fanu

c 04

PC

50.0

0" w

orki

ng r

ange

100.

00"

Max

imum

trav

el a

rea

50"

mat

eria

la

105.

97"

71.8

7"

177.

84"

Peg

a 35

7 le

ngth

31.3

9"49

.21"

5.04"0

27.56"

60.2

1"A

djus

tabl

e 50

" to

90"

Peg

a 35

7 C

ente

rline

72.05" 76.69"

148.74" Pega 357 width

Y axis origin

368.00" Recomended Safety / Maintenance Area 40" from all components

338.

44"

Rec

omen

ded

Saf

ety

/ Mai

nten

ance

Are

a 40

" fr

om a

ll co

mpo

nent

s

Page 6: Pega 357 with 04PC Control Layout Drawings - Used · PDF filePega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Print Date 03/02/2001 Revision 4.0 This document available

Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc.

Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 6 of 9

Plan View - Pega 357 with V357hs Conveyor

Optional Material Support Tables Required

Optional Material Support Tables Required

288.00" Maximum travel area 144" material

Electrical Requirements

Pega 357230 / 460 / 3 / 60 ±10% 18 kVA46 amps @ 230 / 3 / 60 VAC23 amps @ 460 / 3 / 60 VAC

Pega 357

Compressed Air Requirements

80 psi @ 2.9 ft³/min.

P357hs Conveyor208 - 230 / 460 / 3 / 60 ±10% .8 kVA2.1 amps @ 208 / 3/ 60 VAC2.0 amps @ 230 / 3 / 60 VAC1.0 amps @ 460 / 3 / 60 VAC

Indicates Operator Control Station

E1

E1

E2

E2

A1

A1

12" 12" 12"

Scale

PEGA 357

Fanu

c 04

PC

50.0

0" w

orki

ng r

ange

100.

00"

Max

imum

trav

el a

rea

50"

mat

eria

la

105.

97"

71.8

7"

177.

84"

Peg

a 35

7 le

ngth

31.3

9"49

.21"

5.04"0

27.56"

60.2

1"A

djus

tabl

e 50

" to

90"

408.

44"

Rec

omm

ende

d S

afet

y / M

aint

enan

ce A

rea

40"

from

all

com

pone

nts

Peg

a 35

7 C

ente

rline

Y-axis Origin

P35

7hs

Con

veyo

r

Access required this area for slug removal

44.70"70

.01"

72.05" 76.69"

148.74" Pega 357 width

368.00" Recommended Safety / Maintenance Area 40" from all components

Page 7: Pega 357 with 04PC Control Layout Drawings - Used · PDF filePega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Print Date 03/02/2001 Revision 4.0 This document available

Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc.

Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 7 of 9

Plan View - Pega 357 with V357hs Conveyor and MP1225 Loader

441.79" Recomended Safety / Maintenance Area 40" from all components

MP1225 Loader

MP1225Xformer

Access required this areafor material loading / unloading

141.74" MP1225 Loader width

66.5

4"12

3.10

"

189.

63"

MP

1225

Loa

der

Leng

th

Y-axis load position

Optional Material Support Tables Required

Optional Material Support Tables Required

288.00" Maximum travel area 144" material

Electrical Requirements

Pega 357230 / 460 / 3 / 60 ±10% 18 kVA46 amps @ 230 / 3 / 60 VAC23 amps @ 460 / 3 / 60 VAC

Pega 357

Compressed Air Requirements

80 psi @ 2.9 ft³/min.

P357hs Conveyor208 - 230 / 460 / 3 / 60 ±10% .8 kVA2.1 amps @ 208 / 3/ 60 VAC2.0 amps @ 230 / 3 / 60 VAC1.0 amps @ 460 / 3 / 60 VAC

MP1225 Loader

29 amps @ 200 / 3 / 60 VAC

200 / 3 / 60 ±10%, 10 KvaTo operate at 230 / 460 VAC a step up transformer is required with the following service is required

26 amps @ 230 / 3 / 60 VAC13 amps @ 460 / 3 / 60 VAC

MP1225 Loader 75 psi @ 31.8 ft³/min.

Indicates Operator Control Station

E1

E1

E2

E2

E3

E3

A2

A2

A1

A1

PEGA 357

Fanu

c 04

PC

50.0

0" w

orki

ng r

ange

100.

00"

Max

imum

trav

el a

rea

50"

mat

eria

la

105.

97"

71.8

7"

177.

84"

Peg

a 35

7 le

ngth

31.3

9"49

.21"

5.04"0

27.56"

60.2

1"A

djus

tabl

e 50

" to

90"

408.

44"

Rec

omen

ded

Saf

ety

/ Mai

nten

ance

Are

a 40

" fr

om a

ll co

mpo

nent

s

Power Supply

Peg

a 35

7 C

ente

rline

12" 12" 12"

Scale

P35

7hs

Con

veyo

r

Access required this area for slug removal

44.70"70

.01"

72.05" 76.69"

148.74" Pega 357 width

Page 8: Pega 357 with 04PC Control Layout Drawings - Used · PDF filePega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Print Date 03/02/2001 Revision 4.0 This document available

Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc.

Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 8 of 9

End View - Pega 357

37.68"*Material Pass Line

85.59"*

119.84"*

17.32" 30.71"

12" 12" 12"Scale

14.76"29.53"5

35.43"476.69" 72.05"

148.74"7

*Dimension varies with installed options

Page 9: Pega 357 with 04PC Control Layout Drawings - Used · PDF filePega 357 with 04PC Control Layout Drawings ©Amada America, Inc. Print Date 03/02/2001 Revision 4.0 This document available

Pega 357 with 04PC Control Layout Drawings ©Amada America, Inc.

Print Date 03/02/2001 Revision 4.0 This document available on the World Wide Web at http://www.amada.com Page 9 of 9

Elevation View - Pega 357

12" 12" 12"Scale

51.77" Throat Depth50.00" Track 200Working Range

Center Track 200

33.47"32.87"

9.84"

6.50"

11.02"

177.84"

33.47"103.15"7.76"

37.68"* Material Pass Line

62.99"

27.56"

85.59"

*Dimension subject to change with installed options


Recommended