+ All Categories
Home > Documents > Pennsylvania College Of Technology Dauphin Hall

Pennsylvania College Of Technology Dauphin Hall

Date post: 14-Jan-2016
Category:
Upload: elle
View: 33 times
Download: 0 times
Share this document with a friend
Description:
Pennsylvania College Of Technology Dauphin Hall Williamsport, Pennsylvania. Aubert Ndjolba Structural Option AE Senior Thesis- 2011 Thesis Advisor: Dr. Boothby. Existing Building. Proposed Building. Overview. - PowerPoint PPT Presentation
Popular Tags:
22
Pennsylvania College Of Technology Dauphin Hall Williamsport, Pennsylvania Aubert Ndjolba Structural Option AE Senior Thesis- 2011 Thesis Advisor: Dr. Boothby
Transcript
Page 1: Pennsylvania College Of Technology                              Dauphin Hall

Pennsylvania College Of Technology Dauphin Hall Williamsport, Pennsylvania

Aubert NdjolbaStructural OptionAE Senior Thesis- 2011Thesis Advisor: Dr. Boothby

Page 2: Pennsylvania College Of Technology                              Dauphin Hall

IntroductionExisting Structural SystemThesis Proposal

Existing BuildingOverview

Proposed Building

Structural Depth Proposed Solution Slab Design Reinforced masonry Design

Architectural BreadthConclusion

Page 3: Pennsylvania College Of Technology                              Dauphin Hall

Location: Williamsport, PAOwner: Penn College of TechnologyArchitect: Murray Associates Architects, PCGeneral Contractor: IMC Construction, Inc.Number of Stories: 4 Above Grade (70 feet tall,

316 feet long and 210 feet wide)

Building IntroductionDauphin Hall – Penn College of Technology

Seize: 123,676 GSFCost: $ 26,000,000 Construction: October 2008 – August 2010Delivery Method: Design-Bid-Build

Page 4: Pennsylvania College Of Technology                              Dauphin Hall

Foundation: Shallow Foundation Stone Piers ( 18” – 36”) (8) #8’s

Existing Structural SystemDauphin Hall – Penn College of Technology

Page 5: Pennsylvania College Of Technology                              Dauphin Hall

Gravity System: 4” Light Weight Concrete Slab, reinforced

with 1 ½” – 20 gage Vulcraft composite deck

Open Web K-series bar Joists @ 2’-0” O.C.

Existing Structural SystemDauphin Hall – Penn College of Technology

Exterior walls: non-loadbearing CMU with brick Veneer

Interior Partitions: 4” Clay Brick Columns: W8’s – W10’s Beams: W18’s – W24’s

Page 6: Pennsylvania College Of Technology                              Dauphin Hall

Lateral System: Wind Moment Connections in Both

East/West and North/South Direction 22 Total per floor

Existing Structural SystemDauphin Hall – Penn College of Technology

Page 7: Pennsylvania College Of Technology                              Dauphin Hall

Structural Depth Redesign structure using reinforced concrete

masonry loadbearing walls Precast Hollow core planks Design for seven stories

Thesis ProposalDauphin Hall – Penn College of Technology

Construction Management Breadth Compare cost of existing versus proposed

design Generate project schedules

Architectural Breadth Modify existing floor plans Propose an efficient layout that promotes

student collaboration

Page 8: Pennsylvania College Of Technology                              Dauphin Hall

Solution: Gravity System:

Precast hollow core planks Reinforced masonry loadbearing walls 4” Clay brick partitions

Structural DepthDauphin Hall – Penn College of Technology

Lateral System: Reinforced masonry walls as shear walls

Three additional floors 70 feet tall

Proposed Shear Wall Layout

http://www.we-inter.com/Conceptual-Design-for-a-Precast-Concrete-Hotel-in-Iraq.aspx

Page 9: Pennsylvania College Of Technology                              Dauphin Hall

Precast Hollow Core PlanksTypical (Max.) Span = 19 feetDead & Live loads from IBC 2009Selection from catalog (Nitterhouse)

Total Factored Loads W= 190 psf ≤ 214 psf → OK

Structural Depth – Floor DesignDauphin Hall – Penn College of Technology

Use 4-1/2” Strand 8” x 4’-0” hollow core planks with 2” normal weight concrete topping

Courtesy of Nitterhouse

Page 10: Pennsylvania College Of Technology                              Dauphin Hall

Precast Hollow Core Planks Connection Details

Structural Depth – Floor DesignDauphin Hall – Penn College of Technology

Courtesy of NCMA Courtesy of NCMA Courtesy of NCMA

Page 11: Pennsylvania College Of Technology                              Dauphin Hall

Reinforced masonry loadbearing walls: Mostly Corridor and Exterior walls

Dauphin Hall – Penn College of Technology Structural Depth – Shear Wall Design

Assumptions: f’m = 6000psi 8” thickness Fs = 24000 psi Fy = 60000 psi

Page 12: Pennsylvania College Of Technology                              Dauphin Hall

Reinforced masonry loadbearing walls: Designed under gravity loads first At level 1 (base) Load Combination (ASD): D + L Max. Loads P,M = (27.3 kips, 36.40 ft-kips)

Dauphin Hall – Penn College of Technology Structural Depth – Shear Wall Design

Final Design Area steel required: As = 0.85 in2

Use (1) # 9 @ 16” O.C.*Or use (2) # 6’s @ 16” O.C.

Page 13: Pennsylvania College Of Technology                              Dauphin Hall

Wind Loading:Same as existing structure (no change in story height)ASCE 7-05 Wind load cases appliedControlling Case: Load Case 1

Structural Depth – Shear Wall Design

Dauphin Hall – Penn College of Technology

Longitudinal direction controlsBase Shear = 263.6 KipsOverturning Moment = 11,285 ft-kips

Page 14: Pennsylvania College Of Technology                              Dauphin Hall

Seismic Loading:Base shear recalculated due to additional weight of buildingOriginal response modification factor R = 3Intermediate reinforced masonry shear walls R = 3.5

Structural Depth – Shear Wall Design

Dauphin Hall – Penn College of Technology

Base Shear (Kips) Overturning Moment (ft-kips)

Wind 273.6 11,285

Seismic 1663 81,574

Accidental torsional effects = ±0.05% Drift checked against 0.001hsx

Page 15: Pennsylvania College Of Technology                              Dauphin Hall

Check Shear Wall Under Seismic Controlling Load Combination: D + 0.7E (ASCE 7-05) Plot (P,M) = (13,300 lbs; 41,000 lbs-in)

Dauphin Hall – Penn College of Technology Structural Depth – Shear Wall Design

Page 16: Pennsylvania College Of Technology                              Dauphin Hall

Drift Calculations Top Story Drift ∆ = 0.023” ≤ ∆Limit = 0.01hSX = 0.7”→ OK Frist Story Drift ∆ = 0.00025” ≤ 0.7” → OK

Dauphin Hall – Penn College of Technology Structural Depth – Shear Wall Design

Page 17: Pennsylvania College Of Technology                              Dauphin Hall

Dauphin Hall – Penn College of Technology Structural Depth – Shear Wall Design

No Shear reinforcement is needed

Page 18: Pennsylvania College Of Technology                              Dauphin Hall

Floor plans Ceiling height = 10 ft Long corridor More study rooms 124 additional rooms

Dauphin Hall – Penn College of Technology Architectural Breadth

Courtesy of pct.edu

Page 19: Pennsylvania College Of Technology                              Dauphin Hall

Floor plans Ceiling height = 10 ft Long corridor More study rooms 124 additional rooms

Dauphin Hall – Penn College of Technology Architectural Breadth

Courtesy of pct.edu

Page 20: Pennsylvania College Of Technology                              Dauphin Hall

Codes Corridor width = 6’ min Minimum number of Exists = 3 (392 <500) Dead-Ends Travel distance < 250 ft

Dauphin Hall – Penn College of Technology Architectural Breadth

Page 21: Pennsylvania College Of Technology                              Dauphin Hall

Goals Structural implementation feasible Longer construction time frame Additional cost

Dauphin Hall – Penn College of Technology Conclusion

Recommendations: Foundation would need to be checked and

resized

Courtesy of pct.edu

Page 22: Pennsylvania College Of Technology                              Dauphin Hall

Acknowledgements: Murray Associates Architects, P.C Dr. Bill Martin (Owner representative) Penn State AE Faculties Friends/Family

Dauphin Hall – Penn College of Technology Questions/Comments


Recommended