12
Gun Shot Coiled Phasing Density Gun Size Explosive Tubing Slick Line Tubing Wireline Deep Big Hole Gun Type (Degrees) (SPF)Max (inches) Type Conveyed Conveyed Conveyed Conveyed Penetrating Thru Tubing Gun Systems Expendable Strip 0-40-60-90 1-5/8”– Carrier (ESC) 180 6 2-1/8” RDX - HMX x x x x Retrievable Tubing 0-90-60-180 6 1-3/8”– RDX - HMX x x x x x x Gun System (RTG) 2-1/2” PYX Formed Wire (FWC) 0-180 6 1”– 2-1/8” RDX - HMX x x x x Link System 0-45-60-90 4 1-11/16”– RDX - HMX x x x x Carrier (LJC) 180 2-1/8” Swing Jet Carrier 180 4.9 1-3/8” – RDX - HMX x x (SJC) 2-1/8” Bi-Wire Carrier 0-180 4 1-11/16”– RDX - HMX x x x x (BWC) 2-1/8” Casing Gun Systems Ported Hollow Steel 0-120 5 3-1/8”– 5” RDX - HMX x x x x x Carrier (PHSC) PYX Expendable Hollow 0-30-60-90 36 3-1/8”– 7” RDX - HMX x x x x x Steel Carrier (EHSC) 135-140-150 PYX 160 Perforating Services Perforating Wood Group Logging Services
Transcript
Page 1: Perforating Services - Progenda€¦ · Through Tubing Perforating Charge Performance Summary API, RP-43 5th Edition Data ©2000 Wood Group Logging Services Wood Group Logging Services

Gun Shot CoiledPhasing Density Gun Size Explosive Tubing Slick Line Tubing Wireline Deep Big Hole

Gun Type (Degrees) (SPF)Max (inches) Type Conveyed Conveyed Conveyed Conveyed Penetrating

Thru Tubing Gun Systems

Expendable Strip 0-40-60-90 1-5/8”–Carrier (ESC) 180 6 2-1/8” RDX - HMX x x x x

Retrievable Tubing 0-90-60-180 6 1-3/8”– RDX - HMX x x x x x xGun System (RTG) 2-1/2” PYX

Formed Wire (FWC) 0-180 6 1”– 2-1/8” RDX - HMX x x x x

Link System 0-45-60-90 4 1-11/16”– RDX - HMX x x x xCarrier (LJC) 180 2-1/8”

Swing Jet Carrier 180 4.9 1-3/8” – RDX - HMX x x(SJC) 2-1/8”

Bi-Wire Carrier 0-180 4 1-11/16”– RDX - HMX x x x x(BWC) 2-1/8”

Casing Gun Systems

Ported Hollow Steel 0-120 5 3-1/8”– 5” RDX - HMX x x x x xCarrier (PHSC) PYX

Expendable Hollow 0-30-60-90 36 3-1/8”– 7” RDX - HMX x x x x xSteel Carrier (EHSC) 135-140-150 PYX

160

Perforating Services

Perforating

Wood Group Logging Services

Page 2: Perforating Services - Progenda€¦ · Through Tubing Perforating Charge Performance Summary API, RP-43 5th Edition Data ©2000 Wood Group Logging Services Wood Group Logging Services

Bar Activated VentAssembly; 2-7/8” EUE

Wood Group Logging Services’ BAV was developed

to be the primary underbalance valve in drop bar TCP operations.

Designed to operate off of rathole hydrostatic, the BAV operates

independently from tubing hydrostatic pressure.

Benefits� BAV can be operated with dry tubing

� Does not reduce drop bar velocity

� Can be run with any packer

� Once vent opens, BAV is locked in place

Specifications

Bar Activated VentAssembly; 2-7/8” EUE

©2000 Wood Group Logging Services

Wood Group Logging Services

Perforating

Broussard, LA(800) 880-9190

Houma, LA(800) 489-2739

Venice, LA(800) 372-2020

New Orleans, LA(504) 523-0500

Houston, TX (800) 905-4275

Edinburg, TX(888) 336-9457

Pearland, TX (888) 340-9457

Victoria, TX (800) 994-9457

Corpus Christi, TX (888) 527-9457

www.woodg r o u p . c om

O.D. 3.93” 10.0 cm

I.D. 2.25” 5.7 cm

Thread Conn. 2-7/8” EUE

Make-up Length 16” 40.6 cm

Max. Hydrostatic 20,000 PSI 137.9 MPa

Max. Differential 10,000 PSI 68.9 MPa

Min. Hydrostatic 500 PSI 3.5 MPa

Tensile >P-110

Page 3: Perforating Services - Progenda€¦ · Through Tubing Perforating Charge Performance Summary API, RP-43 5th Edition Data ©2000 Wood Group Logging Services Wood Group Logging Services

Shogun Spiral Strip SystemDeep Penetrator & Big Hole

Wood Group Logging Services’ Spiral Shogun, when

combined with the new Shogun N.T. Charge, possesses the

three most important features of an ideal perforator –

Ideal Phasing, Deep Penetration, and High Shot Density.

Benefits

❸ 6 spf in 1-11/16” & 2-1/8” versions

❸ N.T. Shogun charge shoots 40% better than standard Shogun DP charge

❸ 40° & 60° Phasing available

Specifications

Shogun Spiral Strip SystemDeep Penetrator & Big Hole

©2000 Wood Group Logging Services

Wood Group Logging Services

Perforating

Broussard, LA(800) 880-9190

Houma, LA(800) 489-2739

Venice, LA(800) 372-2020

New Orleans, LA(504) 523-0500

Houston, TX (800) 905-4275

Edinburg, TX(888) 336-9457

Pearland, TX (888) 340-9457

Victoria, TX (800) 994-9457

Corpus Christi, TX (888) 527-9457

www.woodg r o u p . c om

O.D. 1-11/16” 2-1/8” 2-1/2”

Min. Restriction 1-25/32” 2-3/16” 2-19/32”

Pressure Rating* 20,000 PSI

Temperature** 375°F

* Shogun N.T. Charge

** HNS/Nona Charge Capable of 450° Available

Page 4: Perforating Services - Progenda€¦ · Through Tubing Perforating Charge Performance Summary API, RP-43 5th Edition Data ©2000 Wood Group Logging Services Wood Group Logging Services

1Unofficial Data

API RP-43 Fifth EditionGun O.D. Charge Shot Charge P/N Expl. 1-hr Casing Section 1Type (in.) Type Density (spf) Wt. (g) Temp. O.D. (in.) (concrete target)

Rating (°F) Entry PenetrationHole (in.) (in.)

Scalloped 2-7/8 SDP 6 TAG-3125-302 15.0 330 4.5 .34 21.90Gun 2-7/8 DP 6 TAG-3125-302LD 15.0 330 4.5 .30 19.46

Systems 2-7/8 BH 6 TAG-3125-3011 15.0 330 4.5 .58 7.002-7/8 BH 6 TAG-3125-301LD1 15.0 330 4.5 .56 6.853-1/8 DP 6 HSC-4000-311T1 23.0 330 4.5 .42 22.253-1/8 DP 9 HSC-3125-301A 10.5 330 4.5 .30 10.263-1/8 BH 9 HSC-3125-310A 11.0 330 5.0 .58 5.813-1/8 BH 12 HSC-3125-310A 11.0 330 5.0 .58 5.183-3/8 DP 5 TAG-3375-460NT 32.0 400 5.0 .40 33.403-3/8 DP 4 TAG-5000-360 32.0 330 4.5 .44 22.203-3/8 DP 6 HSC-4000-311T 23.0 330 4.5 .41 21.533-3/8 DP 6 HSC-4000-3181 26.0 330 4.5 .47 21.533-3/8 DP 6 HSC-4000-311 23.0 330 5.5 .38 18.623-3/8 DP 6 HSC-4000-311ZT 23.0 330 4.5 .37 20.523-3/8 GH 6 HSC-4000-311GH 23.0 330 5.5 .51 14.403-3/8 BH 6 HSC-4000-301LD 20.0 330 5.5 .68 6.883-3/8 BH 6 HSC-3375-301 20.0 330 5 .73 6.053-3/8 BH 12 HSC-3125-310A 11.0 330 5.5 .63 4.87

4 SDP 4 TAG-5000-482 39.0 400 5.5 .46 36.104 DP 5 TAG-5000-313 36.0 330 7 .43 28.014 DP 6 TAG-5000-360 32.0 330 7 .41 26.774 DP 5 HSC-5000-3211 32.0 330 7 .50 26.654 DP 6 HSC-4000-311T1 23.0 330 5.5 .42 23.154 DP 6 HSC-4000-3181 26.0 330 5.5 .43 23.154 DP 6 HSC-4000-311 23.0 330 5.5 .40 20.884 DP 9 HSC-4000-302 19.0 330 5.5 .37 13.214 BH 9 HSC-4000-3011 20.0 330 5.5 .85 7.254 BH 5 HSC-5000-3251 32.0 330 5.5 .90 6.10

4-1/2 SDP 5 SDP-5000-400 39.0 400 7 .37 48.134-1/2 SDP 5 TAG-5000-482 39.0 400 7 .46 37.614-1/2 DP 5 TAG-5000-3131 36.0 330 7 .50 33.404-1/2 DP 6 TAG-5000-360 32.0 330 7 .44 31.554-1/2 DP 5 HSC-5000-3211 32.0 330 7 .55 30.084-1/2 DP 12 HSC-4000-311T 23.0 330 7 .42 18.174-1/2 DP 12 HSC-4000-3111 23.0 330 7 .47 17.314-1/2 BH 5 HSC-5000-3251 32.0 330 7 .88 8.134-1/2 BH 12 HSC-3375-301 20.0 330 7 .72 7.044-1/2 GH 12/16 TAG-5000-306GH1 20.0 330 7 .59 6.284-1/2 BH 12 HSC-4000-301LD 20.0 330 7 .69 6.014-1/2 BH 12/16 TAG-5000-306 20.0 330 7 .73 6.324-1/2 BH 12/16 TAG-5000-306ZF 19.0 330 7 .72 6.964-1/2 BH 24 TAG-4500-302 18.0 330 7 .66 6.01

Scalloped Gun System Perforating Charge PerformanceSummary API, RP-43 5th Edition Data

Scalloped Gun System Perforating Charge PerformanceSummary API, RP-43 5th Edition Data

©2000 Wood Group Logging Services

Wood Group Logging Services

Perforating

Broussard, LA(800) 880-9190

Houma, LA(800) 489-2739

Venice, LA(800) 372-2020

New Orleans, LA(504) 523-0500

Houston, TX (800) 905-4275

Edinburg, TX(888) 336-9457

Pearland, TX (888) 340-9457

Victoria, TX (800) 994-9457

Corpus Christi, TX (361) 299-9457

www.woodg r o u p . c om

Page 5: Perforating Services - Progenda€¦ · Through Tubing Perforating Charge Performance Summary API, RP-43 5th Edition Data ©2000 Wood Group Logging Services Wood Group Logging Services

API RP-43 Fifth EditionGun O.D. Charge Shot Charge P/N Expl. 1-hr Casing Section 1Type (in.) Type Density (spf) Wt. (g) Temp. O.D. (in.) (concrete target)

Rating (°F) Entry PenetrationHole (in.) (in.)

Scalloped 4-5/8 BH 12 LS HSC-4000-301 20.0 330 7 .74 6.10

Gun 4-5/8 BH 24 TAG-4500-302 18.0 330 7 .67 5.49

Systems 5-1/8 DP 5 TAG-5000-3131 36.0 330 7 .49 29.58

5-1/8 DP 6 TAG-5000-3601 32.0 330 7 .42 27.78

5-1/8 DP 5 HSC-5000-3211 32.0 330 7 .53 26.47

5-1/8 DP 12 HSC-4000-311T1 23.0 330 7 .42 19.13

5-1/8 DP 12 HSC-4000-3111 23.0 330 7 .46 18.22

5-1/8 BH 12/16 TAG-5000-3061 20.0 330 7 .72 6.87

5-1/8 BH 12 TAG-5000-306ZF 19.0 330 7 .71 7.05

5-1/8 BH 12 HSC-4000-301LD1 20.0 330 7 .72 6.67

5-1/8 GH 12/16 TAG-5000-306GH1 20.0 330 7 .59 6.47

7 SDP 12 TAG-5000-482 39.0 400 9.625 .45 33.41

7 DP 12 TAG-5000-313 36.0 330 9.625 .47 28.49

7 BH 12/16 TAG-7250-312 47.5 330 9.625 1.13 7.54

7 BH 12/16 TAG-7250-312LD 47.5 330 9.625 1.06 8.19

7 BH 12 TAG-7250-334Z1 60.0 330 9.625 1.05 8.19

7 BH 12 TAG-7000-351Z1 39.0 330 9.625 .98 7.50

Scalloped Gun System Perforating Charge PerformanceSummary API, RP-43 5th Edition Data

Scalloped Gun System Perforating Charge PerformanceSummary API, RP-43 5th Edition Data

©2000 Wood Group Logging Services

Wood Group Logging Services

Perforating

Broussard, LA(800) 880-9190

Houma, LA(800) 489-2739

Venice, LA(800) 372-2020

New Orleans, LA(504) 523-0500

Houston, TX (800) 905-4275

Edinburg, TX(888) 336-9457

Pearland, TX (888) 340-9457

Victoria, TX (800) 994-9457

Corpus Christi, TX (361) 299-9457

www.woodg r o u p . c om

1Unofficial Data

Page 6: Perforating Services - Progenda€¦ · Through Tubing Perforating Charge Performance Summary API, RP-43 5th Edition Data ©2000 Wood Group Logging Services Wood Group Logging Services

Through Tubing Perforating Charge Performance SummaryAPI, RP-43 5th Edition DataThrough Tubing Perforating Charge Performance SummaryAPI, RP-43 5th Edition Data

©2000 Wood Group Logging Services

Wood Group Logging Services

Perforating

Broussard, LA(800) 880-9190

Houma, LA(800) 489-2739

Venice, LA(800) 372-2020

New Orleans, LA(504) 523-0500

Houston, TX (800) 905-4275

Edinburg, TX(888) 336-9457

Pearland, TX (888) 340-9457

Victoria, TX (800) 994-9457

Corpus Christi, TX (361) 299-9457

www.woodg r o u p . c om

1Unofficial Data

API RP-43 Fifth EditionGun O.D. Charge Shot Charge P/N Expl. 1-hr Casing Section 1Type (in.) Type Density (spf) Wt. (g) Temp. O.D. (in.) (concrete target)

Rating (°F) Entry PenetrationHole (in.) (in.)

Swing Jet II 1-3/8 xSystems 3-3/4 DP 4.9 STK-3750-401SJ 11.0 375 4.5 .34 18.01

1-11/16x 3-7/8 DP 4.4 STK-4250-402NTX 18.0 375 4.5 .30 30.73

2-1/8 x5-3/8 DP 3.5 STK-5500-401SJ 32.0 375 7 .43 35.15

Shogun 1-5/8 DP 6 STP-1625-301 9.5 310 4.5 .39 9.13Systems 1-11/16 SDP 6 STP-1687-401NTX 8.4 375 5 .23 18.39

1-11/16 SDP 6 STP-1687-401NT 9.0 375 5 .24 16.401-11/16 DP 6 STP-1687-301E 8.4 310 4.5 .35 11.221-11/16 BH 6 STP-1687-401NB 8.8 375 5 .40 9.571-11/16 BH 6 STP-1687-301BH 10.8 310 5.5 .48 9.03

2 DP 6 STP-2000-3011 17.5 310 5.5 .43 15.082-1/8 SDP 6spf STP-2125-401NTX 13.9 375 5.5 .25 26.93

@40o

2-1/8 SDP 6spf STP-2125-401NT 14.0 375 5.5 .27 23.64@40o

2-1/8 DP 6 STP-2125-301E 18.0 310 5.5 .43 16.172-1/8 BH 6 STP-2125-401NB 13.4 375 5.5 .50 11.852-1/8 BH 6 STP-2125-301BH 19.0 310 5.5 .62 12.062-1/2 SDP 4spf STP-2500-401NT1 24.5 375 7 .33 34.70

@0o

2-1/2 SDP 4spf STP-2500-401NTX 26.4 375 5.5 .34 36.44@60o

2-1/2 SDP 4spf STP-2500-401NT 24.5 375 5.5 .35 33.33@60o

Bi-Wire 1-11/16 DP 4 BWC-1687-3011 11.0 310 5.5 .37 6.55Systems 2-1/8 DP 4 BWC-2125-3021 22.0 310 5.5 .45 10.55

Formed Wire 1-11/16 DP 4 FWC-1687-3011 11.0 310 5.5 .37 6.55Systems 2-1/8 DP 4 FWC-2125-3021 22.0 310 5.5 .45 10.55

Link 1-11/16 DP 4 LNK-1687-3011 11.0 310 5.5 .37 6.55Systems 2-1/8 DP 4 LNK-2125-3021 22.0 310 5.5 .45 10.55

Retrievable 1-11/16 SDP 4 RTG-1687-401NT 3.5 400 4.5 .18 8.14Tubing Gun 1-11/16 DP 4 RTG-1687-3011 3.2 330 4.5 .22 6.20

Systems 1-11/16 BH 4 RTG-1687-301BH1 3.3 330 4.5 .49 3.602-1/8 SDP 6 SDP-2125-402NTX 6.5 400 4.5 .26 20.132-1/8 SDP 4 RTG-2125-401NT 6.7 400 4.5 .29 13.482-1/8 DP 4 RTG-2125-302 6.5 330 4.5 .29 10.732-1/8 GH 6 RTG-2125-302GH1 6.4 330 5.5 .40 6.352-1/8 BH 4 RTG-2125-302BH1 6.4 330 5.5 .50 3.602-3/8 SDP 4 TAG-2375-402NT 10.0 400 4.5 .25 18.102-3/8 DP 4 TAG-2375-401BH 10.0 400 4.5 .47 7.202-1/2 SDP 6 TAG-2500-402NT1 11.0 400 4.5 .32 18.572-1/2 SDP 4 RTG-2500-305 13.0 330 4.5 .32 18.572-1/2 DP 6 RTG-2500-3021 11.0 330 4.5 .34 14.63

Page 7: Perforating Services - Progenda€¦ · Through Tubing Perforating Charge Performance Summary API, RP-43 5th Edition Data ©2000 Wood Group Logging Services Wood Group Logging Services

RDX

Time vs. Temperature Chart for ExplosivesTime vs. Temperature Chart for Explosives

©2000 Wood Group Logging Services

Wood Group Logging Services

Perforating

Broussard, LA(800) 880-9190

Houma, LA(800) 489-2739

Venice, LA(800) 372-2020

New Orleans, LA(504) 523-0500

Houston, TX (800) 905-4275

Edinburg, TX(888) 336-9457

Pearland, TX (888) 340-9457

Victoria, TX (800) 994-9457

Corpus Christi, TX (361) 299-9457

www.woodg r o u p . c om

1 2 3 4 6 810 24 48 100 200

TThhiiss cchhaarrtt iiss iinntteennddeedd ffoorr rreeffeerreennccee ppuurrppoosseess oonnllyy.Explosive systems ratings are developed on many factors. We recommend that the end user contact Wood Group LoggingServices for technical assistance for the following conditions:

❸ TCP operations involving HNS or PYX explosives❸ Exposed Wireline operations above 12,500 psi or 310°F❸ Hollow Carrier wireline operations above 375°F

In any case, the end user must be able to satisfy himself to the suitability of any Wood Group product for a given condition.

1 2 3 4 6 810 24 48 100 200

600°F (316°C)

575°F (302°C)

550°F (288°C)

525°F (274°C)

500°F (260°C)

475°F (246°C)

450°F (232°C)

425°F (218°C)

400°F (204°C)

375°F (191°C)

350°F (177°C)

325°F (163°C)

300°F (316°C)

275°F (135°C)

250°F (121°C)

225°F (107°C)

200°F (93°C)

PYX & NONA

HNS

HMX

Time (Hours)

Page 8: Perforating Services - Progenda€¦ · Through Tubing Perforating Charge Performance Summary API, RP-43 5th Edition Data ©2000 Wood Group Logging Services Wood Group Logging Services

Wood Group Logging Services

puts safety first when it comes to electrical detonation

systems for downhole operations. The Safety InterlockTM

EFI System is the only electrical system on the market that

eleminates the “Human Error Factor”.

Benefits

� No Shut Down of Normal Rig Activity

� Impact Insensitive

� RF (EMI), ESD, Stray Current Safe (AC & DC)

� Cannot be fired without Electronic Controller

� No Primary or Sensitive Explosives

� 400o Temperature Rating for 24 Hours

� 25k PSI Maximum Pressure

EFIInitiationSystem

EFIInitiationSystem

©2000 Wood Group Logging Services

Wood Group Logging Services

Perforating

Broussard, LA(800) 880-9190

Houma, LA(800) 489-2739

Venice, LA(800) 372-2020

New Orleans, LA(504) 523-0500

Houston, TX (800) 905-4275

Edinburg, TX(888) 336-9457

Pearland, TX (888) 340-9457

Victoria, TX (800) 994-9457

Corpus Christi, TX (888) 527-9457

www.woodg r o u p . c om

Page 9: Perforating Services - Progenda€¦ · Through Tubing Perforating Charge Performance Summary API, RP-43 5th Edition Data ©2000 Wood Group Logging Services Wood Group Logging Services

Wood Group Logging Services’PWP tool measures gamma rays, temperature of the well and bottom

hole pressure during perforating operations. The PWP saves valuable

time and reduces frequency of wireline trips.

Specifications

Perforating WithPressure ToolPerforating WithPressure Tool

©2000 Wood Group Logging Services

Wood Group Logging Services

Perforating

Broussard, LA(800) 880-9190

Houma, LA(800) 489-2739

Venice, LA(800) 372-2020

New Orleans, LA(504) 523-0500

Houston, TX (800) 905-4275

Edinburg, TX(888) 336-9457

Pearland, TX (888) 340-9457

Victoria, TX (800) 994-9457

Corpus Christi, TX (888) 527-9457

www.woodg r o u p . c om

1 - 11/16” PEERRFFOORRAATTIINNGG GAAMMMMAA PRREESSSSUURREE TEEMMPPEERRAATTUURREE

Tool Diameter 1 11/16”

Length 98.12”

Weight 35 lbs.

Temperature Rating 350° F

Pressure Rating 18,000 PSI

Operating Voltage 120 VDC, Scint/Press/Temp(Gun fires on negative voltage)

Logging Speed/Time Constant 10 ft./Min. - 6 sec.20 ft./Min. - 3 sec.30 ft./Min. - 2 sec.

17.62”

57.31”

67.05”

98.12”

9.74

PRESSURESUB PLUG

CENTER OFCOIL

CENTER OFDETECTOR

Scintillation and Geiger Gamma Rays Available

Scintillation Shown

Page 10: Perforating Services - Progenda€¦ · Through Tubing Perforating Charge Performance Summary API, RP-43 5th Edition Data ©2000 Wood Group Logging Services Wood Group Logging Services

Pressure ActivatedTime Delay Firing SystemPressure ActivatedTime Delay Firing System

Wood Group Logging Services’ High Pressure Time Delayed Firing Head (TDF) permits underbalance perforating through the use of a pressure actuated firing head employing a time delay fuse. The use of the time delay allows for time (9-10 minutes) to bleed the actuating pressure off the tubing, to achieve the desiredunderbalance, prior to firing the guns. The system may also be usedwith perforate and stimulate TCP to adjust the overbalance prior to the guns firing.

Benefits❸ Independently perforate selected zones.

❸ Fire several guns independently during one trip

❸ Obtain maximum utilization of underbalance

❸ Not affected by annulus pressure; can be run in heavy mud systems

❸ Can be used with full/or non-full opening tools

❸ Multiple guns can be run without gun spacers to reduce costs

❸ The TDF is ideal for production completions, drill stem testing, dual completions, and coiled tubing operations

❸ Recommended for running on top and/or bottom of gun assemblies

❸ Time delay extensions may be added for additional time in10 minutes intervals (for N2 operations)

Specifications

©2000 Wood Group Logging Services

Wood Group Logging Services

Perforating

Broussard, LA(800) 880-9190

Houma, LA(800) 489-2739

Venice, LA(800) 372-2020

New Orleans, LA(504) 523-0500

Houston, TX (800) 905-4275

Edinburg, TX(888) 336-9457

Pearland, TX (888) 340-9457

Victoria, TX (800) 994-9457

Corpus Christi, TX (888) 527-9457

www.woodg r o u p . c om

O.D. 1.68” 4.3 cm

Make-up Length 27.2” 69.1 cm

Max. Hydrostatic 20,000 PSI 137.9 MPa

Min. Hydrostatic 2,000 PSI 13.8 MPa

Page 11: Perforating Services - Progenda€¦ · Through Tubing Perforating Charge Performance Summary API, RP-43 5th Edition Data ©2000 Wood Group Logging Services Wood Group Logging Services

Differential Firing Head AssemblyDifferential Firing Head Assembly

Wood Group Logging Services’ Differential Firing Head

DFH was developed to allow low pressure actuation of TCP Guns.

Benefits

❸ Underbalance perforating in horizontal wells without a packer

❸ Pressure balanced when run in hole for improved safety

& reliability

❸ Can be adapted to run as an annulus pressure operated

firing head using Packer Bypass System

❸ Can be run with Bar Activated Vent to open vent when firing

❸ Can be utilized with Time Delay fuses to provide time to

reduce applied pressures.

Specifications

©2000 Wood Group Logging Services

Wood Group Logging Services

Perforating

Broussard, LA(800) 880-9190

Houma, LA(800) 489-2739

Venice, LA(800) 372-2020

New Orleans, LA(504) 523-0500

Houston, TX (800) 905-4275

Edinburg, TX(888) 336-9457

Pearland, TX (888) 340-9457

Victoria, TX (800) 994-9457

Corpus Christi, TX (888) 527-9457

www.woodg r o u p . c om

O.D. 3.13” 7.9 cm

Make-up Length 18.5” 47 cm

Max. Hydrostatic 20,000 PSI 137.9 MPa

Max. Differential 12,500 PSI 86.1 MPa

Min. Hydrostatic 250 PSI 1.7 MPa

Page 12: Perforating Services - Progenda€¦ · Through Tubing Perforating Charge Performance Summary API, RP-43 5th Edition Data ©2000 Wood Group Logging Services Wood Group Logging Services

Redundant AnnulusPressure Firing SystemRedundant AnnulusPressure Firing System

Wood Group Logging Services’ Redundant Annulus

Pressure Firing System (R-APF) was designed to allow underbalance

perforating for shoot and pull applications. The R-APF accomplishes

this by using differential pressure across the packer to actuate the

firing mechanism. Utilized with Packer Bypass system.

Benefits❸ Full bore design

❸ Can be used with any other Firing Head on top of the R-APF

❸ Can be used for Drill Stem Testing (DST) and shoot and pull applications

❸ Ideal for deviated wells

Specifications

©2000 Wood Group Logging Services

Wood Group Logging Services

Perforating

Broussard, LA(800) 880-9190

Houma, LA(800) 489-2739

Venice, LA(800) 372-2020

New Orleans, LA(504) 523-0500

Houston, TX (800) 905-4275

Edinburg, TX(888) 336-9457

Pearland, TX (888) 340-9457

Victoria, TX (800) 994-9457

Corpus Christi, TX (888) 527-9457

www.woodg r o u p . c om

O.D. 3.88” 9.8 cm

Make-up Length 32.5” 82.5 cm

Max. Hydrostatic 20,000 PSI 137.9 MPa

Max. Differential 10,000 PSI 68.9 MPa

Min. Hydrostatic 250 PSI 1.7 MPa


Recommended