Performance! Release March 06, 2017 Performance!Nxt Release 12.7170 Flowserve is pleased to announce the latest release of Performance!Nxt, the industry's foremost Control Valve Sizing, Selection and Project Management Software. Following are details about new product, features, enhancements implemented and issues resolved in this release. New Product: FlowAct diaphragm actuator sizing & selection enabled for Mark One The Valtek Mark One linear control valve extends its VL cylinder actuator options to include the redesigned and effective FlowAct diaphragm actuator. The new FlowAct actuator is accurately sized and selected for the Mark One control valve for high performance control. The Mark One/FlowAct control valve is available for project quoting of 26 weeks from Bangalore, Singapore, Suzhou, Springville and Villach. The following is the product offering overview: Mark One & FlowAct diaphragm actuator NPS sizes: 0.5, 0.75, 1, 1.5, 2, 3, 4 and 6 Pressure ratings: class 150, 300 and 600 Body materials: all materials are available Severe service: all trims are available Packing: all types and materials are available Seat configuration and shutoff: all options are available Positioners: All Logix positioners are available including the 3000, 500 and 400 series Actuator: All FlowAct actuator handwheel configurations are available
Transcript

Performance! Release

March 06, 2017

Performance!Nxt Release 12.7170 Flowserve is pleased to announce the latest release of Performance!Nxt, the industry's foremost Control Valve Sizing, Selection and Project Management Software. Following are details about new product, features, enhancements implemented and issues resolved in this release. New Product: FlowAct diaphragm actuator sizing & selection enabled for Mark One

The Valtek Mark One linear control valve extends its VL cylinder actuator options to include the redesigned and effective FlowAct diaphragm actuator. The new FlowAct actuator is accurately sized and selected for the Mark One control valve for high performance control. The Mark One/FlowAct control valve is available for project quoting of 26 weeks from Bangalore, Singapore, Suzhou, Springville and Villach. The following is the product offering overview:

Mark One & FlowAct diaphragm actuator

NPS sizes: 0.5, 0.75, 1, 1.5, 2, 3, 4 and 6 Pressure ratings: class 150, 300 and 600 Body materials: all materials are available Severe service: all trims are available Packing: all types and materials are available Seat configuration and shutoff: all options are available Positioners: All Logix positioners are available including the 3000, 500 and 400 series Actuator: All FlowAct actuator handwheel configurations are available

Performance! Release

New Product: New SideWinder Anti-Cavitation Trim for Low Flow Applications

Cavitation is common in many liquid control valve applications. In particular, high pressure drop, small flow applications within the Oil & Gas, Chemical, Power and Aerospace industries experience destructive cavitation. Cavitation control is highly valued by customers and is an important factor that influences procurement decisions for control valve equipment. The SideWinder severe cavitation elimination technology simultaneously uses all six proven anti-cavitation pressure drop mechanisms including; small passages, turns, mutual impingement, sudden expansion and contraction to absorb and control pressure drop energy, neutralizing the root cause of cavitation. The new trim is fully integrated in the latest release of Performance!Nxt, allowing users to size and select a configuration that ensures effective cavitation elimination in high pressure, low flow applications. A new cavitation prediction logic developed specifically for the SideWinder trim allows fast and accurate sizing and selection of the SideWinder trim for Mark One Series Globe and Angle body styles. Performance!Nxt is programed to automatically select the most suitable SideWinder trim solution for a given application. It works with application data and calculation method as entered by the user and automatically generates the best configuration for the application. This not only allows users to provide technically competitive solutions but also offers greater reliability and performance to customers. If additional information is required, please contact Bradford Haines at [email protected]

mailto:[email protected]

Performance! Release

New Application Template: Mark One and Valdisk enabled for selection with Pressure Swing Adsorption (PSA) applications Available for North American operations and sales channels, Performance!Nxt can size and select Mark One and Valdisk valves for PSA (Pressure Swing Adsorption) applications. This new application template automatically triggers correct sizes, classes and materials for PSA applications including high-cycle actuators. Data sheets also include Flowserves updated SPP-2140 outlining the correct material selection and assembly procedures. Following are the main features of the PSA application valves: Mark One NPS Sizes: 1 to 8 Pressure ratings: class 150 and 300 Trim materials: 316 SS and alloy 6 seat surface Trim options: standard and MegaStream Packing: SafeGuard or SureGuard or SureGuard XT Seat Configuration and shutoff: soft seat; class IV or VI Guides: glass loaded PTFE or alloy 6 Actuator: VL-UHC Valdisk Size: 2 - 24 inch Pressure Rating: class 150, 300 and 600 Packing: SureGuard, SafeGuard and SureGuard XT Shaft/Pin Material: Inconel Seat Configuration and Seat Material: Soft-UHC and UHMWPE Actuator: SuperNova To create PSA valves in P!Nxt application, please refer to instructions by clicking following link: User Instruction Creation of PSA valves

Instructions for creating PSA records.

1. Click New button from Valve Manager.

2. On doing so, the Valve selection dialog is displayed.

3. Next, retain SPR-Springville USA or select any other North American sites (including EDM but not PIT site) from Manufacturer drop-down.

4. Please select Industry radio button in the Selection Criteria area.

5. Next, in the Industry drop down, select any of the options except Unknown and Water.

6. In the Process drop down, select Industrial Gases option.

7. In the Application drop down, select PSA option. On doing so, PSA Mark One and Valdisk valve models will be displayed in Valve selection dialog.

8. Next, select Mark One or Valdisk model from this window and click OK; the Valve

window will be displayed.

9. Next, follow the regular procedure to size and select the record.

With this procedure, you will get the PSA valves sized and selected.

10133247File Attachment

Performance! Release

New Product: ColdFlow 341000 A new cryogenic valve, Kammer ColdFlow 341000 is now available for sizing and selection. The following is the product offering overview: Size: DN4 to DN 200 (DIN) and 0.16 to 8 inch (ANSI) Pressure Rating: PN 40 (DIN) and CL 300 (ANSI) End connections: Buttweld Bonnet Type: Angle Extended Body Style: Angle Flow Direction: Flow Under, Flow Over Shutoff: Class IV, Class V and Class VI Actuators: KP Diaphragm, KF Diaphragm, FlowAct, KM Manual, KE Electric Accessories added for Valbart products Multiple accessories are added to LPS and RG actuator with TMCBV valve at Sulphur Springs site. These include: VRG Controllers ASCO Solenoids and needle valves Fisher Quick Exhausts, air regulators, air filter regulator and relief valves Fairchild boosters Swagelok check valve Generant relief valve Product configuration are also updated for following PMV products D3, D20, D30 and EP5 positioners

Performance! Release

New Product: Inclusion of LPC pneumatic compact scotch yoke (for TMCBV, TX3, Valdisk and for External Sizing) With the scope to continue growing Control Valves and Automation businesses, a new P!Nxt development has been recently completed, complementing past release 12.7151 dated October 2016 and 12.7160 dated December 2016.

In 12.7170 Release LPC Actuators automatic selection is enabled for TMCBV, TX3 and Valdisk and for all other ON/OFF Flowserve Valves (or Third Party valves) using a Template Excel file for importing into P!NXT the valve torques. With this new release 12.7170 it will be possible to automatic select LPC compact pneumatic scotch-yoke actuators in addition to the previously added LPS actuators. Until now, only LPS actuators could be selected in P!NXT from Limitorque Fluid Power Range. With this new release, LPC Pneumatic Compact Scotch Yoke actuators will be now automatically sized in P!Nxt, offering a more compact solution for small valve sizes. The User will be allowed to automatically select the proper LPC actuator model, considering the actual valve process and shutdown conditions and proper actuator sizing parameter (e.g. Safety Factors, Supply Pressure, ...). P!Nxt users are still allowed to manually select different actuator models, using the Actuator Size and Spring Size Override option available inside the User Interface (UI) screen. LPC accessories and additional options can be also selected inside the Specification Screen.

Performance! Release

Pricing is currently set to CF; it should be enabled shortly by means of a P!Nxt Database update, along with an additional note to the distribution list. Stroking Time calculation is currently not available for LPC actuators and it will be part of future developments. User Instructions and Sizing Procedure for LPC actuators Detailed Users Instructions have been created as separate document and are here embedded inside the following pdf file:

User Instructions LPC Sizing on TMCBV, TX3 and Valdisk Valves in P!NXT User Instructions LPC External Sizing in P!NXT

User Instructions March 6th, 2017

1

Automatic Selection of LPC actuators in P!Nxt for

TMCBV, TX3 and VALDISK Valves

Procedure and steps to Size LPC Actuators on TMCBV, TX3 and VALDISK valves 1. Select a TMCBV, TX3 or VALDISK valve and go Performance! Sizing screen.

Specify the fluid and the process conditions.

2. Next, go to the Actuator User Interface Area and select LPC among all other available actuators; then some Input Data for Actuator Sizing need to be provided:

User Instructions March 6th, 2017

2

a. Service: Modulating/On-Off

b. Supply pressure: Minimum and Maximum values available on-site to feed

the actuator

Note 1: Minimum pressure corresponds with the Sizing Pressure; it also normally corresponds to the Reducer Pressure Set, whenever a Pressure Reducer is installed on actuator control panel

Note 2: Those values are normally provided inside the Project Instrument Datasheet and Specifications or provided by Customer

c. Ambient Temperature: Minimum and Maximum values of Ambient

Temperature foreseen on-site where the valve/actuator assembly will be installed

Note 3: This temperature range is different from the process condition temperature range

Note 4: Those values are normally provided inside the Project Instrument Datasheet and Specifications or provided by Customers

d. Safety Factors (SF): by clicking on SF button, a new screen will open allowing inserting Safety Factors values for both Process Condition and Valve Shutoff Condition (if different).

User Instructions March 6th, 2017

3

Safety Factors can be also identical for every valve position or different for each of the 6 main valve positions; they are defined as per following definitions:

=BTOactuator

BTOvalve 1 =

RTOactuator

RTOvalve 1 =

ETOactuator

ETOvalve 1

=BTCactuator

BTCvalve 1 =

RTCactuator

RTCvalve 1 =

ETCactuator

ETCvalve 1

=MAX Act Torque

MAST_valve 1

Where the following terminology is adopted:

BTO = Break to Open torque BTC = Break to Close torque

RTO = Running to Open torque RTC = Running to Close torque

ETO = End to Open torque ETC = End to Close torque

MAST = Maximum Allowable Stem Torque

Note 5: SF on BTO, RTO, ETO, BTC, RTC, ETC is a value greater than 1: for example SF_BTO = 1.2 means that BTO_actuator is 20% higher than BTO_valve

Note 6: SF_MAST is a value between 0 and 1: for example SF_MAST = 0.9 means that Maximum Actuator Torque will be limited to 90% of valve MAST

e. Yoke: User has the possibility to select only Symmetrical Option for LPC

Yoke type: i. Symmetrical Scotch Yoke only

ii. Canted (not available for LPC) iii. Optimized Yoke (not available for LPC)

f. Act Config: one of the following option has to be selected: i. Spring Return SA (single acting) ii. Double Acting

User Instructions March 6th, 2017

4

g. Fail Action: one of the following action has to be selected:

for Spring Return-SA:

i. FC-FCW (Fail Close Fail Clockwise)

ii. FO-FCCW (Fail Open Fail Counterclockwise)

iii. FL (Fail Lock by means of Lock up valve in control system)

for Double Acting:

i. Fail As Is

ii. FC-FCW (Fail Close Fail Clockwise by means of Air Tank)

iii. FO-FCCW (Fail Open Fail Counterclockwise by means of Air Tank)

Note 9: Please note that any Lock-up valve or Air Tank (complete w/ relevant isolation valves, gauges, relief, tubing and fittings,) will have to be manually added in the Specification Sheet.

h. Air To: option indicates if the air open or close the valve. This information is

strictly related to Fail Action: for example a Spring Return Single Acting actuator in FC-FCW Fail Close configuration will have the Air To Open option only available and selected by default.

i. Shutoff DP: give to the user the possibility to specify the pressure Shutoff

value across the valve for actuator sizing: it can be imposed equal to P1 which is the Upstream Pressure to the valve or can be manually input by the User

j. Actuator Size: this field shows the Actuator and Cylinder size of the automatically selected LPC model

k. Spring Size: this field shows the Spring Size of the automatically selected

LPC model

l. Actuator Model: this field shows the entire model nomenclature of the automatically selected LPC model

User Instructions March 6th, 2017

5

m. Override Options of Actuator Size and Spring Size: this options are represented by padlock symbols:

If unlocked then the Override is disabled and the auto-size is enabled. If locked, then the Override is enabled and auto-size is disabled,

overridden by the specified actuator size and spring size manually selected by the User among those available in the dropdown menu.

When an Actuator Size is overridden with a selection that does not satisfy all the sizing parameters, then it is shown in red color with a red cross beside. User is invited not to proceed with that specific selection or to carefully check the Actuator Screen to verify the reason, before any decision to proceed.

3. After selecting the desired options and input the required Safety Factors and Ambient Temperatures, then click on Calculate button

4. Open the Actuator Screen to verify the automatic selection and to visualize the selected LPC actuator performances:

User Instructions March 6th, 2017

6

The Valve required Torques inclusive of the safety factors are shown on top part of the Actuator screen: if different process conditions are inserted in addition to the Max DP at Shutoff, then the actuator will be selected based on Max Driving Force which considers the highest torques requested by the valve in various different positions.

Actuator selected model will be displayed in the first column of Actuator Comparison/Selection area, with relevant Output Torques. Other alternative models are also provided in the subsequent columns, but they would probably meet the torque requirements as highlighted in red color. Acting on the left side of the screen, the User would be able to modify some sizing parameters, before freezing the selection.

User Instructions March 6th, 2017

7

5. Check VIOLATIONS / WARNINGS messages:

a. TX3 and VALDISK butterfly valve MAST calculation Warning:

b. Valve MAST violation:

c. Valve MAST violation 2:

d. Actuator MOP violation:

User Instructions March 6th, 2017

8

e. Actuator MAWP violation:

6. Once LPC model is automatically sized, then select the Specification button from

Performance! Sizing screen and go to Actuator tab. In this tab, User can specify attributes/values other than the model code attributes/values. In the specification dialog, you can select values for different attributes such as Manual Override, Coating/Color, Air Volume Tank, Fittings, Actuator Mounting and so on.

User Instructions March 6th, 2017

9

7. When the actuator sizing and selection is done, you can print the spec sheet by

using the Print option. The actuator selections made will be populated in the actuator section of the spec sheet.

Basics of Scotch Yoke actuators sizing Due to the scotch-yoke mechanism, LFPS quarter-turn actuators (LPS, LPC and LHS models) have a particular U-shaped output torque curve whether powered by a fixed supply pressure or the spring. For a proper actuator model selection, the safety factors between actuator output torque and valve torque requirement shall be calculated at least in six points along the valve stroke. In addition a final check is necessary to guarantee that actuator Maximum Output Torque does not exceed valve Maximum Allowable Stem Torque (MAST).

Spring Return Scotch Yoke Actuator Opening Stroke (by supply pressure)

User Instructions March 6th, 2017

10

Spring Return Scotch Yoke Actuator Closing Stroke (by spring)

The minimum set of parameters and features necessary for an optimal actuator

selection:

Valve torques, including MAST

Type of actuator:

Single Acting/Spring Return: Fail Safe Close (CW) or Fail Safe Open (CCW)

Double Acting configuration for Fail Last or Fail As Is

Minimum, Normal and Maximum Pneumatic/Hydraulic Supply Pressure to the actuator

Safety Factors requested by the project or by a specific application

Working Temperature range

Open/Close stroking times

Additional options (pressure reducer, safety relief valve, control panel, hydraulic power unit, limit switch box, positioner, manual override )

Definitions box:

BTO = Break to Open torque BTC = Break to Close torque

RTO = Running to Open torque RTC = Running to Close torque

ETO = End to Open torque ETC = End to Close torque

MAST = Maximum Allowable Stem Torque SF = Safety Factor

User Instructions March 6th, 2017

11

Contacts

For any further information or clarification please contact:

Lorenzo Colonna Automation Global Technical Specialist - [email protected]

mailto:[email protected]

mailto:[email protected]

10133247File Attachment

User Instructions March 6th, 2017

1

LPC sizing in P!Nxt on FLS Valves not included in P!Nxt and

on any 3rd Party Valves using External Excel Template

Procedure to Download the LFPS External Sizing Excel Template From the Valve Manager screen it is possible to download the LFPS External Sizing Excel Template from the Top Bar under Tools menu. Selecting LFPS External Sizing a new window will appear.

By Clicking on Download Template it will be possible to Save the template locally on your PC for filling out the Valve Torques and the necessary Actuator Sizing Parameters.

LFPS External Sizing Template is an Excel file composed by two sheets: Sizing_Data and Instructions. In Sizing_Data all necessary Input fields are the yellow background colored cells.

User Instructions March 6th, 2017

2

Please follow the Instructions embedded in the Excel Template and included also in this User Manual.

HOW TO SIZE LPS and/or LPC ACTUATORS USING P!NXT AND EXTERNAL EXCEL TEMPLATEStep 1

Step 2

Step 3

Step 4

Step 5

Step 6

Step 7

Step 8

Step 9

Step 10

LPS and/or LPC External Sizing in P!NXT - User Instructions rev.106/03/2017

This document contains proprietary information that is the property of Flowserve Corporation. This document may not, in whole or in part , be duplicated , disclosed to other than the present recipient , or used for

any other purpose without the written permission of Flowserve Corporation. This document shall be returned upon request.

Make sure P!NXT is installed on your PC; if it is not the case you can refer to www.flowserveperformance.com

Start P!NXT application

From the Valve Manager screen click on "Tools" and then select "LFPS External Sizing" from the dropdown menu

A new window "LPS Sizing using External Valve Torques" will be displayed with two enabled buttons: "Download Template" and "Import"

By clicking on "Download Template" you will be able to download the most recent available version of this excel template. You need to "Save As" the template in a local folder.

After downloading the template in a local folder, you can fill out all the necessary sizing data in yellow cells of the Sizing_Data spreadsheet of the Template (Columns C, D and from I to AE); compared from

previous revision, now columns S, V, S, AC are recommended but not mandatory. Please refer to next Instructions Paragraph for detailed explanations about sizing data.

After filling out all the necessary data, just save and close the template file; then click on "Import" button and browse the local folder, linking to the template file

After "Importing" operation, the "Calculate" button will be enabled; by clicking on "Calculate" button the automatic LPS and/or LPC Sizing calculation will be performed.

After "Calculation" operation, the "Export" button will be enabled: by clicking on "Export" button the template file will be opened showing the LPS and/or LPC actuator selected models in column "AF", along

with the actuator Output Torques and Warning/Violations messages.

In case of Successful Sizing a "OK" message will be displayed for each Item in column "A"; in case of failed sizing a "FAILED" message will be displayed in column "A" for each failed item. In this latter case,

please check correctness of Input data and/or modify them: then repeat the sizing operation from Step 7 to Step 9.

User Instructions March 6th, 2017

3

UNIT OF MEASUREMENT SELECTION

Torque

in-lbf

ft-lbf

Nm

Before filling out Input Data inside the "Sizing_Data" spreadsheet, it will be possible to select the proper Units of Measurements inside the top left part area of the "Sizing_Data" spreadsheet.

Volume Pressure Temperature

m3 psi(g) F

l bar(g) R

galUS MPa C

U.S.bbl kg/cm2 K

in3 atm

Torque Volume Pressure Temperature

Nm l bar(g) C

UNIT OF MEASUREMENTS SELECTION

INPUT DATA DETAILSCOLUMN A

COLUMN B

COLUMN C

COLUMN D

COLUMN E

COLUMN F

COLUMN G

COLUMN H

COLUMN I

COLUMN J

COLUMN K

COLUMN L

COLUMN M

COLUMN N

COLUMN O

COLUMN P

COLUMN Q

COLUMN R

COLUMN S

COLUMN T

COLUMN U

COLUMN V

COLUMN W

COLUMN X

COLUMN Y

COLUMN Z

COLUMN AA

COLUMN AB

COLUMN AC

COLUMN AD

COLUMN AE

Sized (OK or FAILED) OK if successfully sized or FAILED in case of failed sizing due to wrong input data or because it is not possible to find a suitable actuator meeting all the

sizing requirements a the same time

Item Progressive number of items (up to 1000)

P - Pneumatic Pneumatic Actuator type

Actuator Series LPS and/or LPC actuator type available as only available selection at the moment

TAG Valve Tag Number (optional)

Size Valve Size (optional)

Class Valve Class (optional)

Q.ty Item quantity (optional)

Act Config Actuator configuration: one of the following option has to be selected: i. Spring Return SA (single acting) ii. Double Acting

Fail Action Fail Action: one of the following action has to be selected:

for Spring Return-SA:

i. FC-FCW (Fail Close Fail Clockwise)

ii. FO-FCCW (Fail Open Fail Counterclockwise)

iii. FL (Fail Lock by means of Lock up valve in control system)

for Double Acting:

i. Fail As Is

ii. FC-FCW (Fail Close Fail Clockwise by means of Air Tank)

iii. FO-FCCW (Fail Open Fail Counterclockwise by means of Air Tank)

Air To Air To: option indicates if the air open or close the valve. This information is strictly related to Fail Action: for example a Spring Return Single Acting

actuator in FC-FCW Fail Close configuration will have the Air To Open option only available and selected by default.

Symmetrical /Canted or Optimized Yoke Yoke: User has the possibility to select three options:

i. Symmetrical Scotch Yoke only

ii. Canted Scotch Yoke only (only for LPS)

iii. Optimized Scotch Yoke (only for LPC)

Symmetrical/Canted options will impose automatic sizing to provide an LPS model with Symmetrical/Canted scotch yoke respectively. Optimized Yoke

option will allow automatic sizing to provide the most convenient LPS actuator model that satisfy all the sizing requirements, independently if it is a

Symmetrical or Canted scotch yoke.

Modulating / On-Off Service Type: On-Off selection is available for "LFPS External Sizing"; if Modulating is requested then please use standard P!NXT valve and actuator

selection

T Min Ambient Temperature: Minimum and Maximum values of Ambient Temperature foreseen on-site where the valve/actuator assembly will be installed.

This temperature range is different from the process condition temperature range. Those Temperatures values are normally provided inside the Project

Instrument Datasheet and Specifications or provided by CustomersT Max

Min Supply Supply pressure: Minimum and Maximum values available on-site to feed the actuator. Minimum pressure corresponds with the Sizing Pressure; it also

normally corresponds to the Reducer Pressure Set, whenever a Pressure Reducer is installed on actuator control panel. Those values are normally provided

inside the Project Instrument Datasheet and Specifications or provided by Customer Max Supply

BTO S.F. Safety Factors can be also identical for every valve position or different for each of the 6 main valve positions; they are defined as per following

definitions:

Note: SF on BTO, RTO, ETO, BTC, RTC, ETC is a value greater than 1: for example SF_BTO = 1.2 means that BTO_actuator is 20% higher than BTO_valve

Note: SF_MAST is a value between 0 and 1: for example SF_MAST = 0.9 means that Maximum Actuator Torque will be limited to 90% of valve MAST

RTO S.F.

ETO S.F.

BTC S.F.

RTC S.F.

ETC S.F.

MAST S.F.

BTO Valve Torques Values.

The following terminology is adopted:

BTO = Break to Open torque BTC = Break to Close torque

RTO = Running to Open torque RTC = Running to Close torque

ETO = End to Open torque ETC = End to Close torque

MAST = Maximum Allowable Stem Torque

RTO

ETO

BTC

RTC

ETC

Max Allowable Valve (MAST)

User Instructions March 6th, 2017

4

OUTPUT DATA & VIOLATION/WARNING MESSAGES EXPLANATIONCOLUMN AF

COLUMN AG

COLUMN AH

COLUMN AI

COLUMN AJ

COLUMN AK

COLUMN AL

COLUMN AM

COLUMN AN

COLUMN AO

COLUMN AP

COLUMN AQ

COLUMN AR

COLUMN AS

COLUMN AT

COLUMN AU

COLUMN AV

COLUMN AW

COLUMN AX

COLUMN AY

COLUMN AZ

ACTUATOR Actuator model that has been automatically selected by P!Nxt as to be the most economically convenient one meeting all the sizing requirements

BTO [at Pmin] Actuator Break To Open Torque calculated at Minimum Pressure (sizing pressure) inserted in cell "P"

RTO [at Pmin] Actuator Run To Open Torque calculated at Minimum Pressure (sizing pressure) inserted in cell "P"

ETO [at Pmin] Actuator End To Open Torque calculated at Minimum Pressure (sizing pressure) inserted in cell "P"

BTC [at Pmin] Actuator Break To Close Torque calculated at Minimum Pressure (sizing pressure) inserted in cell "P"

RTC [at Pmin] Actuator Run To Close Torque calculated at Minimum Pressure (sizing pressure) inserted in cell "P"

ETC [at Pmin] Actuator End To Close Torque calculated at Minimum Pressure (sizing pressure) inserted in cell "P"

BTO [at Pmax] Actuator Break To Open Torque calculated at Maximum Pressure (sizing pressure) inserted in cell "Q"

RTO [at Pmax] Actuator Run To Open Torque calculated at Maximum Pressure (sizing pressure) inserted in cell "Q"

ETO [at Pmax] Actuator End To Open Torque calculated at Maximum Pressure (sizing pressure) inserted in cell "Q"

BTC [at Pmax] Actuator Break To Close Torque calculated at Maximum Pressure (sizing pressure) inserted in cell "Q"

RTC [at Pmax] Actuator Run To Close Torque calculated at Maximum Pressure (sizing pressure) inserted in cell "Q"

ETC [at Pmax] Actuator End To Close Torque calculated at Maximum Pressure (sizing pressure) inserted in cell "Q"

Actuator Volume Actuator Volume (Cylinder Volume)

Actuator M.O.P. Actuator Maximum Operating Pressure

Actuator M.A.W.P. Actuator Maximum Allowable Working Pressure

MOP Violation

Additional messages reported from automatic selection; for each Violation Message's explanation , please refer to the comments included in the cells

AV10, AW10, AX10, AY10 and AZ10 of the "Sizing_Data spreadsheet". Alternatively please refer to below section.

MAWP Violation

MAST Violation

MAST Violation 2

MAST Violation 3

VIOLATION/WARNING MESSAGES

e. Valve MAST violation 3:

a. Actuator MOP violation:

b. Actuator MAWP violation:

c. Valve MAST violation:

d. Valve MAST violation 2:

User Instructions March 6th, 2017

5

Contacts

For any further information or clarification please contact:

Lorenzo Colonna Automation Global Technical Specialist - [email protected]

Flowserve - Performance! Team [email protected]

ERROR MESSAGES

e. Maximum Number of Items Exceeded: f. File is already opened:

g. Input Data Missing:

mailto:[email protected]

mailto:[email protected]

10133247File Attachment

Performance! Release

Issues resolved Linear Issues

21703: Anti-Cavitation Trim SideWinder is now available for sizing and selection with Mark One valve. SideWinder is a specialized cavitation elimination trim applicable for high pressure drop, small flow applications. 24142: The XTP - pressure differential ratio factor of a control valve with attached fittings at choked flow, is now considered in calculation of expansion factor Y for MegaStream G3. 24278: When the calculated system noise falls near to zero, it is shown as 0 instead of < 70.0 in the respective field of sizing screen. This issue is fixed for Megastream G3. 23542: A user reported that once the Sigma MR value was overridden, it was retained even after changing the retainer type/trim size. This issue is resolved. The Sigma MR override value is cleared now if any change in made in valve model, body size, body style, flow direction, trim size or retainer type. 23120: A user reported that special class Mark One displayed pressure class violation for specific process conditions. The selected configuration was valid for specified process conditions. This issue is resolved now.

19545: Kammer ColdFlow 341000, a new cryogenic valve is now available for sizing and selection. 24141: The P2 Back calculation is improved for MegaStream G3. 23846: All options available for FlowTop valve at Villach site are now available at Bangalore site also. 24098: Trim sizes 4.38B and 4.38C are added for 12 inch Mark One with MegaStream retainer. 22975: CMTR options available for Mark One valve are enabled for Valtek GS valve at Singapore, Bangalore and Springville sites. 23698: While sizing Mark 100 with Stealth trim, an error message "Error retrieving Stealth Area data...Calculations are suspect..." was displayed. This issue is resolved.

Performance! Release

Rotary Issues 24130: MaxFlo 3 is deactivated for selection at all sites. New MaxFlo 3 records cannot be created. However, old MaxFlo 3 records can be opened in the application. Also, users will be able to revise and copy the old records. 23895: MaxFlo 4 Cv values at 5% and 10% rotations are updated for all configurations. 23621: End post material rule is updated for MaxFlo 4 with NACE. Now, end post material is set similar to shaft material, i.e. 17-4PH H1150D. 23466: Body bolting rules are updated for MaxFlo 4 at all sites except Villach. If A351-CF8M (SS) is selected as body material, the body bolting and end post bolting materials are set to A 193-B8 / A 194-8. The existing rules for these material are retained for Villach site. 24043: A user reported incorrect Cv calculation for Valdisk 18 inch. This issue is resolved. 23099: O-Ring option is enabled for Valdisk, MaxFlo 4, ShearStream HP packing materials. If O-Ring option is selected in Packing dialog, then Packing-O Ring Seal is set to EPDM.

Actuator & Accessory Issues 22713: A new compact LFPS pneumatic actuator, LPC is now available for selection and sizing with TMCBV, Valdisk and Valdisk TX3 valves. This actuator can also be sized with Non Flowserve valves. 20543: FlowAct diaphragm actuator is now available for selection and sizing with Mark One valves at Springville, Bangalore, Singapore, Villach and Suzhou. 23973: A bug was reported by User about incorrect display of MOP Violation message when LPS actuators were selected using the DASR configuration on TMCBV valves. More specifically the MOP Violation message was displayed also in some cases in which the Maximum Pressure supplied to the actuator was lower than the effective MOP (Maximum Operating Pressure) of a specific LPS actuator model. Now the issue has been resolved and validated.

Performance! Release

23781: With the scope to provide P!NXT Users with enhanced features when sizing LPS and/or LPC importing the Valve Torques into P!NXT by using external Template Excel file, the following features have been incorporated inside this 7170 release:

Ability to size of LPS and LPC actuators also in cases in which Valve MAST is not provided (or input equal to 0 zero)

Possibility to extract LPS and LPC torque values at both Pmin and Pmax

Capability to display LPS and LPC Swept Volume

Sizing using ft-lbs Engineering Units (in addition to previously available Nm and in-lbs)

Sizing of LPS and LPC actuators even if RUN valve torques are not provided by the User

23356: A user reported an error in double acting Turnex actuator sizing. The torques shown in Static Open were shown under Breakout and vice versa. This issue is resolved now. 24023: Spring set 0.2 1.0 bar is available for selection in NR actuators with shaft down configuration. 23977: Upon request from Sulphur Springs site, product definition updates have been made for PMV products D3, EP5 and F5. 21752: Various third part accessories are added for LPS and RG actuators for selection at Sulphur Springs sites. These include Fairchild boosters, ASCO solenoids, Regulators, Relief valves, VRG controllers and so on. Issue # 23976 was resolved as a child issue of 21752. 23700: For XL positioner if a user selects Stainless Steel material paint, only Stainless Steel gauges are available for selection. All other Brass options are blocked now. 23041: A user reported issue about incorrect display of Air supply pressure units on spec sheet of Kammer Act sub, KP and KA actuators. This issue is resolved now. 24308: A user reported issue about incorrect display of Air supply values on spec sheet of LPS actuator. This issue is resolved now.

Performance! Release

23982: A user reported that selection of new NR actuator sizes was setting actuator sizes as Blank for MaxFlo 3 valves. The records with 60-degree stroke were pointing to 80-degree stroke data which causes this error. This issue is resolved now. 22910: The Fail Position options of FlowAct actuator are renamed for 3-Way FlowTop valve.

For 3-way diverging configuration, the updated fail positions are: Close (angle way open) Open (angle way close) For 3-way converging configuration, the updated fail positions are: Close (angle way close) Open (angle way open)

23585: Product definition and rules have been corrected for solenoid model FESTO 570786 / 570785. Application Issues 24058: While navigating between different records, Shutoff DP entered with 3 decimal places accuracy was rounding to 2 decimal places. This issue is resolved. Similar kind of another rounding off issue with Shutoff DP (issue # 24267) is also resolved. 24155: The generator code (used to create parts list) is updated in the application. 23661: A new liquid flow rate unit Barrels per hour (bbl/h) is added into application. 23790: A new liquid flow rate unit Pounds per minute (lb/min) is added into application. 24171: The help file for Performance!Nxt 12.7170 release is updated. 18981: If changes are made in sourcing restriction and delivery schedules in the Project dialog, the same changes are cascaded to all record (new and existing) in the same project.

Performance! Release

User Interface Issues 21308: Revise and Replace options are now activated in Duplicate/Revision/Revise/Skip dialog. This dialog is displayed while importing/exporting records having tag name and alternate number exactly same between the two DBs concerned. 18114: Users are now able to see the page number in front of tag number for a record in Sizing screen. 23986: A user reported that report builder extracted Durco brand as a language in the report. This issue is resolved. Thanks to all who contributed to this release. Please continue to report all issues in our tracker: http://www.flowserveperformance.com/performtracker Flowserve - Performance! Team [email protected] Disclaimer: Flowserves audit of Performance!Nxt Version 12.7170 determined that the resulting software output is consistent with industry standard calculations and Flowserve product design data. Flowserve welcomes reports of any error that might be discovered in the software and will promptly address each issue.

http://www.flowserveperformance.com/performtrackermailto:[email protected]