ZOLOSCAN2 COMBUSTION MONITORING SYSTEMZoloSCAN™2 is an innovative, laser-based combustion
monitoring system that utilizes proven TDLAS technology
as recommended by API RP556. The system simultaneously
measures the temperature, O2, CO, CH4 and H2O in real-time,
directly in a reformer, ethylene cracking furnace or process
heater along multiple laser paths. There are no probes to
insert, no sensitive electronics near the furnace, and no
calibration required. ZoloSCAN2 measurements provide a
more accurate and reliable representation of the combustion
gases present in a furnace than traditional, single-point
thermocouples or ZrO2 sensors.
KEY FEATURES• Multiple constituents
- Simultaneously measures temperature,
O2, CO, CH4 and H2O
• Cost-effective installation
- Multiple measurement paths per ZoloSCAN2 system
- Minimal infrastructure requirements
- Install without a heater outage
- Div2/Zone2 Hazardous Location capable
- Nitrogen or air purging not required
• Continuous reporting
- Automatic SensAlign Head alignment maintains
reliable and accurate measurements
- Minimal maintenance required
COMBUSTION OPTIMIZATION
PETROCHEMICAL & REFINING
OnPointSolutions.com© 2020 Koch Engineered Solutions. All rights reserved.
A KOCH ENGINEERED SOLUTIONS COMPANY
Find out what ZoloSCAN2
can do for [email protected]
100°
10.125 18
14.250
IMPROVED SPACIAL RESOLUTIONZoloSCAN2 provides zonal measurements of
key constituents to increase the precision of
combustion control inside the furnace. The data
provided assists for targeted feedback in large
heaters where combustion imbalances can lead
to production constraints, hot spot, reduced
availability, or high emissions.
TEMPERATURE-ENHANCED MEASUREMENT ACCURACYZoloSCAN2’s innovative design takes
temperature readings along the same
path as other species measurement for
more accurate data with no auxiliary
thermocouple-based temperature
feedback uncertainties.
PATENT-PENDING SIGHT-PORT MOUNTZoloSCAN2’s minimal infrastructure requirements (reduced conduit, reflective mirror, sight port retrofit and a locally installed
cabinet) simplify installation and reduce costs. The sight-port retrofit option allows you to swing the ZoloSCAN2 active head
open (like a door) for easy sight-port viewing into your furnace.
Sight Port Retrofitwith ZS2 Active Head
PROVEN TECHNOLOGYZoloSCAN2 utilizes a proven technique known as
Tunable Diode Laser Absorption Spectroscopy (TDLAS).
Zolo’s TDLAS uses multiple lasers, each tuned to unique
absorption constituents to measure multiple species
and temperature at each laser path location.
PROVEN VALUEMultiplexed TDLAS laser systems are the industry benchmark
for reduced maintenance and increased reliability and control of
combustion optimization. Zolo systems have been successfully
installed in over 100 industrial applications around the world and
continue to provide long-term value.
AUTOMATED PATH ALIGNMENTSensAlign™ heads automatically adjust position to maintain continuous alignment and peak laser power. This results in extremely
robust, uninterrupted reporting that accommodates warping furnace or boiler walls.
Traditional Sensors: Other laser-based systems typically defocus their beam to ensure alignment. This practice results in loss of
signal strength leading to reduced measurement performance and residual sensitivity to wall warpage.
BENEFITS• Increase productivity/output
-Optimizeheatfluxprofiles
-Maximizefurnaceavailability
-Increaseprocessyields
•Extendprocesstubelife
-Eliminatelocalizedhotspots
-Increasedecokingintervals
-Increasecatalystlife
•Fuelsavings
-LowerexcessO2
-Optimizeair/fuelratiosacrosstheheater
• Lower emissions
-ReduceNOx,COandCO2
• Safety/sentry
-Real-timevisibilityintostartupandshutdown
-AlarmtohighCOduringheateroperation
-AlarmtohighCH4 during heater start-up
- Detect higher amounts of steam in the furnace
indicatingpossibletuberupture
•Easeofinstallation/use
-Minimalinfrastructureneededforinstallation
-Sight-portmountconvenientlyswings
ZoloSCAN2awayforeasyflameviewing
- Measurement path purging with air or N2
not required
To learn more about our solutions, go to: OnPointSolutions.com© 2021 Koch Engineered Solutions. All rights reserved.
SENSALIGN HEADSFeatures
Active Heads
Automatic Alignment ± 2.5 deg range
Local Indicator Light Green (measuring), Yellow (open), Red (error)
Weight 11 kg (24 lbs)
Dimensions 285 mm D x 215 mm W x 225 mm H (11.3 in. D x 8.7 in. W x 8.9 in. H)
Passive Heads
Hardened Reflecting Mirror Head alignment not required
Weight 9 kg (20 lbs)
Dimensions 110 mm D x 175 mm W x 200 mm H (4.4 in. D x 7.0 in. W x 8.0 in. H)
Measurement Path
Low Maintenance Hinged head, easy to open and clean window
Purge Air/N2 Not required
Cooling Air Not required
Alerts / Health Checks Signal Strength, Temperature, Open Head
Installation ConditionsOperating Temperature -20 to 85 °C R.H. 0-100%, (-4 to +185 F)
Ingress Protection IP54
Sight Tube Installation 75mm Ø (3”) cutout in refractory and furnace for tube penetration
Sight Port Installation Outage not typically required for sight port replacement, Multiple sight port sizes available
Hazardous Classification Class I Division 2 / Zone 2, (NEC / ATEX / IECEx)
Conduit (Active Head to J-Box) Hi-temp flex conduit - electrical and fiber optics
Conduit (J-Box to Rack) 38mm (1.5 in) O.D. typical - electrical and fiber optics
Electrical 48V CAN bus supplied by Control Rack, no local power required
ZOLOSCAN2 CONTROL CABINETFeatures
Data Output OPC UA/DA via Ethernet TCP/IP, Additional protocols available via Kepware converter
User Interface ZoloSCAN BalanceApp for combustion visualization
Species Measurements Path and zone data for all measured species
Alert / Health Checks Laser status, temperature, comm errors
Lock-out Tag-out Available Yes, main power disconnect
Remote Access Available Yes, for remote monitoring and support
Installation ConditionsAmbient Temperature -20 to 55 °C R.H. 0-100%, (-4 to +131 F)
Ingress Protection IP66 (Stainless)
Weight 353kg (780 lbs)
Hazardous Options Class I Division 2 / Zone 2, (NEC / ATEX / IECEx)
Electrical Requirements 230/240 Vac, Single Phase, 50/60Hz , 25A (10A/15A)
Dimensions 1220 mm W x 1525 mm H x 560 mm D (60”W x 60”H x 18”D)
MEASUREMENT SPECIFICATIONSMeasurement Species Combined Temperature, O2, CO, CH4 and H2O on every measurement path
Measurement System Multiplexed Tunable Diode Laser Absorption Spectroscopy (TDLAS)
Available Paths per System 1 to 12
Pressure Range 0.8 to 1.1 atm
Optical Path Length 1 to 30 meters (3 to 98 feet)
Applicable Fired Gasses Natural Gas, LPG, Waste Gas, Naphtha, Hydrogen, and others
Dust Sensitivity Negligible for typical firing conditions
Path Measurement Time 10 seconds Typical per path duration
Complete Furnace Profile Total path count X 10 sec Typical cycle duration (e.g. 12 paths = 2 minutes)
On-site Calibration Not-required Self-calibrated every 24 hours
Constituent Full Scale Range Accuracy Precision Temperature Range
Temperature 260 to 1700° C ± 1.0% fs ± 0.5% fs N/A
O2 % 0 to 30% ± 0.25% abs ± 0.125% abs 260 to 1700° C
CO % (ppm) 0 to 10,000 ± 50 to 200 ± 25 to 100 500 to 1700° C
CH4 % 0 to 10% ± 0.5% abs ± 0.25% abs 25 to 500° C
H2O % 0 to 30% ± 1.0% abs ± 0.50% abs 260 to 1700° C
* fs = full scale abs = absolute Specifications based on nominal installation, actual results will vary based on installation specific criteria.