    PowerFactory: Functions   1

    DIgSILENT PowerFactory Functions

  • 8/9/2019 PF Feature Func Over

    2/12

    PowerFactory: Functions   2

    Load Flow/Transmission

    Fast and Accurate Load Flow Algorithm (Full Newton Raphson,

    Newton-Raphson Current Iteration)

     AC and DC Networks (for HVDC Transmission)

    Secondary Power-Frequency Control

    Primary Control

    Secondary Reactive Power-Voltage Control

    Load Profiling

    P-V Curves

     All Types of Sensitivities (dv/dQ, dphi/dP, Branch Sensitivities etc.)

    Modal dv/dQ Analysis

  • 8/9/2019 PF Feature Func Over

    3/12

    PowerFactory: Functions   3

    Load Flow/Distribution

     Any Type of Network Technology:

    Three-Phase,Three-Phase-Four Wire, Two-Phase, Bi-Phase,

    Single Wire-Earth Return, DC Networks

     Any Type of Network Topology (Meshed and Radial)

    Suited for Extremely Large MV Networks (>20000 Bus Bars)

    Voltage Profile Diagrams

    Stochastic Load Models for Considering Load Diversity in LV

    Networks

    One- and Two-Dimensional Load Profiles

    Feeder Scaling

    Open Point Optimization

  • 8/9/2019 PF Feature Func Over

    4/12PowerFactory: Functions   4

    Active and Reactive Power 

    Dispatch

    Loss Minimization

    Fuel Cost Minimization

    Branch Flow Limits

    Bus Bar Voltage Limits

     Active/Reactive Power Limits

    Stator Current Limits

    Reserve Constraints

  • 8/9/2019 PF Feature Func Over

    5/12PowerFactory: Functions   5

    Short Circuit

    Short Circuits According to IEC 60909, ANSI C37 and Complete

    Superposition Method

    Full Implementation of IEC 60909/2001

    Multiple Faults Analysis

    Fault Types:

    Three-Phase

    Two-Phase

    Two-Phase to Ground

    Single-Phase to Ground

    Inter-Circuit (also Between Different Voltage Levels)

    Open Conductor 

    Sliding Faults along Lines

  • 8/9/2019 PF Feature Func Over

    6/12

    PowerFactory: Functions   6

    Stability

    Transient and Dynamic

    Stability

    Highly Accurate Generator and Load Models

    Large Library of Standard

    Models

    User Defined Modeling

    Variable Step Size Algorithm

    Easy-to-Use Chart Definition Interactive Event Definition

    Small Signal Analysis (Modal

     Analysis)

    Simulates

    Any Unbalanced Fault Scenario

  • 8/9/2019 PF Feature Func Over

    7/12

    PowerFactory: Functions   7

    Electromagnetic Transients

    Detailed Network Model

    Transformer Saturation Transformer Capacitances

    Distributed Parameter Line

    Models (Constant andFrequency Dependent)

    Detailed (Switching) Power 

    Electronics Device Models

    Easy-to-Use Chart Definition

    Interactive Event Definition

    Variable Step Size Algorithm

  • 8/9/2019 PF Feature Func Over

    8/12

    PowerFactory: Functions   8

    Overcurrent Protection Modeling

    CT and VT Models

    Fuses

    OCT-Relays

    Directional Relays

    Differential RelaysLV Circuit Breakers

    Coordination

    Selectivity Diagrams

    Simulation

    Steady State

    Time Domain

  • 8/9/2019 PF Feature Func Over

    9/12

    PowerFactory: Functions   9

    Distance Protection Modeling

    CT and VT Models

    MHO-Characteristics

    Quadrilateral Characteristics

    X/R-Blinder 

    Starting Characteristics

    Inter-Tripping Schemes Coordination

    R-X Diagrams

    Time-Distance Diagrams Simulation

    Steady State

    Time Domain

  • 8/9/2019 PF Feature Func Over

    10/12

    PowerFactory: Functions   10

    Harmonics

    Balanced and Unbalanced Harmonic Sources

    Characteristic, Non-Characteristic and Inter-Harmonics

    Frequency- and Time-Domain Charts

    Harmonic Loadflow

    Frequency Scan

    Frequency Dependent Line

    Parameters

    Distributed Parameter Line Models

    Filter Sizing

  • 8/9/2019 PF Feature Func Over

    11/12

    PowerFactory: Functions   11

    Reliability

    Weibul-Markov Failure Models

    Line/Transformer/Bus Bar Failures

    Common Mode Failures

    Double Earth Faults

    Circuit Breaker Failures

    Protection Failures

     Analytical State Enumeration

    Monte Carlo Simulation  Advanced System Restoration Models including Generator 

    Dispatch and Load Shedding

  • 8/9/2019 PF Feature Func Over

    12/12

    PowerFactory: Functions   12

    DPL (DIgSILENT Programming

    Language)

     Arithmetic operations, standard functions Virtual object functions

    Logic operations, lLoops: do{……..} while(…)

     Alternative: if(….) then{….} else{…}

     Access to any system parameter 

    Use of every command

    Every command can be used

    Definition of result files, creation of plots


Recommended