18
DEPARTMENT OF PHARMACY UNIVERSITY OF MALTA Pharmaceutics IV PHR4308 Practicals Handbook Practical 1: Buffering Pharmaceutical Preparations Practical 2: Extemporaneous Preparations Practical 3: Particle Size Distribution Pharmaceutics Co-ordinator: Prof Anthony Serracino-Inglott Compiled by Marie Clare Zammit Updated by Nicolette Bartolo January 2012
Transcript

DEPARTMENT OF PHARMACY

UNIVERSITY OF MALTA

Pharmaceutics IV

PHR4308

Practicals Handbook

Practical 1: Buffering Pharmaceutical Preparations

Practical 2: Extemporaneous Preparations

Practical 3: Particle Size Distribution

Pharmaceutics Co-ordinator: Prof Anthony Serracino-Inglott

Compiled by Marie Clare Zammit

Updated by Nicolette Bartolo

January 2012

PHR 4308

ASI/NB/MCZ/MZA 2012 2

Practical 1

BUFFERING PHARMACEUTICAL PREPARATIONS

Name: Group: Date:

AIM Investigation of the buffering capacity of systems of interest to the pharmaceutical industry APPARATUS Beakers 4 x 100ml Burette 1 x 50ml Electronic balance Magnetic stirrer Measuring cylinder 1 x 50ml pH meter MATERIALS Boric acid Citric acid Phosphoric acid 2g/100ml Potassium Dihydrogen Phosphate Sodium Hydroxide 0.1M Sodium Hydroxide 0.5M WARNING: The pH meter electrode is very fragile. Handle with care. Always rinse well with water after using it. Leave in fresh distilled water when ready. METHOD

i. Fill two burettes, one with the 0.1M and the other with the 0.5M sodium hydroxide

solution.

ii. Accurately weight about 0.155g of boric acid.

iii. Dissolve the boric acid in 50ml water using a magnetic stirrer.

iv. Place the pH meter electrode in the solution making sure that the stirrer does not hit the

electrode bulb (lower end of electrode).

v. When the pH is steady take the reading.

vi. Add 1ml of 0.1M sodium hydroxide solution, from the burette, to the boric acid solution

while stirring and keeping the pH meter electrode in the solution. When adding the

sodium hydroxide solution, make sure that it goes directly into the solution.

vii. Take the reading of the pH when it is steady.

viii. Keep repeating step v and vi until the pH is above 11.

ix. Accurately weight about 2.01g of citric acid and repeat steps ii to vii using 0.5M sodium

hydroxide. Continue until the pH is above 12.

PHR 4308

ASI/NB/MCZ/MZA 2012 3

x. Place 50ml of phosphoric acid in a beaker and use a magnetic stirrer to mix the

solution.

xi. Place the pH meter electrode in the solution making sure that the stirrer does not hit the

electrode bulb.

xii. When the pH is steady take the reading.

xiii. Keeping the electrode in the solution and the solution stirred, add 1.0ml of 0.5M sodium

hydroxide solution from a burette making sure that the sodium hydroxide goes directly in

the solution.

xiv. When the pH is steady take the reading.

xv. Keep repeating steps xii and xiii until the pH is above 11.

xvi. Accurately weight about 0.354g of potassium dihydrogen phosphate.

xvii. Dissolve in 50ml water using the magnetic stirrer.

xviii. Place the pH meter electrode in the solution making sure that the stirrer does not hit the

electrode bulb.

xix. When the pH is steady take the reading.

xx. Keeping the electrode in the solution and the solution stirred, add 1.0ml of 0.1M sodium

hydroxide solution from a burette making sure that the sodium hydroxide goes directly in

the solution.

xxi. When the pH is steady, take the reading.

xxii. Keeping repeating steps xix and xx until the pH is above 11.5.

QUESTIONS 1. Calculate the molarity of each of the solutions used.

Calculations

Solution Molarity

Boric acid

Citric acid

Phosphoric acid 2g/100ml

Potassium Dihydrogen Phosphate

PHR 4308

ASI/NB/MCZ/MZA 2012 4

2. Plot a graph of pH against volume of sodium hydroxide added for each solution. Comment on the graphs obtained.

PHR 4308

ASI/NB/MCZ/MZA 2012 5

PHR 4308

ASI/NB/MCZ/MZA 2012 6

PHR 4308

ASI/NB/MCZ/MZA 2012 7

PHR 4308

ASI/NB/MCZ/MZA 2012 8

3. What inferences can be made from the graphs obtained in 2?

_________________________________________________________________________

_________________________________________________________________________

_________________________________________________________________________

_________________________________________________________________________

_________________________________________________________________________

_________________________________________________________________________

_________________________________________________________________________

4. Using a mixture of the buffers studied, how would it be possible to have a buffer capable

of buffering between pH 2 and pH 9?

_________________________________________________________________________

_________________________________________________________________________

_________________________________________________________________________

_________________________________________________________________________

_________________________________________________________________________

_________________________________________________________________________

PHR 4308

ASI/NB/MCZ/MZA 2012 9

REFERENCES 1. Aulton ME, ed. Pharmaceutics: The science of dosage form design. 2nd ed. New York:

Churchill Livingstone; 2002. 2. European Pharmacopoeia. 7th ed. Germany: Druckerei CH Beck, Volume1 2010:746-7.

3. Remington: The science and practice of pharmacy. 21st ed. UK: Pharmaceutical press;

2011.

4. Sinko PJ. Martin’s physical pharmacy and pharmaceutical sciences. 6th ed. US: Lippincott Williams & Wilkins; 2011.

Demonstrator Name Signature

PHR 4308

ASI/NB/MCZ/MZA 2012 10

Practical 2

EXTEMPORANEOUS PREPARATIONS

Name: Group: Date:

AIM

To make an extemporaneous preparation of an ointment and suspension

APPARATUS

Electronic balance

Glass plate

Wooden spatula

Plastic container

Mortar and pestle

Glass funnel

Glass bottle

Labels

Gloves

MATERIALS

Petroleum jelly

Salicylic acid

Tablet X 100mg

Sodium benzoate

METHOD

Ointment preparation

i. Calculate the amount of petroleum jelly and salicylic acid required to produce 10g of ointment containing 1% salicylic acid.

ii. Clean and dry well the glass plate.

iii. Place the glass plate on the balance and press Tare.

iv. Weigh accurately the amount of petroleum jelly required, as calculated.

v. Remove the glass plate from the balance and put the plastic container instead and press tare.

vi. Weigh accurately the amount of salicylic acid required, as calculated.

vii. Put the salicylic acid on the ointment and mix them by moving the spatula in the figure of 8 repeatedly.

viii. Collect the prepared ointment using the wooden spatula and place it in the plastic container used to weigh the salicylic acid.

ix. Mix the ointment again in the plastic container to ensure that any traces of salicylic acid powder previously left in the container are amalgamated well into the ointment.

PHR 4308

ASI/NB/MCZ/MZA 2012 11

x. Label the ointment produced.

xi. Repeat steps ii to ix to prepare 10g of ointment containing petroleum jelly and salicylic acid at a ratio of 11:0.25 respectively.

Suspension preparation

A patient came to the pharmacy with the following prescription:

i. Provided that the dosage strength of the tablets available containing substance X is

100mg, calculate the amount of tablets X and volume of water required to produce a

10mg/ml suspension.

ii. Calculate the weight of sodium benzoate required (0.1% w/v) for the suspension, to act

as a preservative.

iii. Mix the sodium benzoate with the calculated volume of water (referred to as vehicle).

iv. Pulverise the tablets using a mortar and pestle.

v. Add one third of the vehicle to the pulverised tablets and triturate the powder until a

uniform suspension is achieved.

vi. Transfer the suspension produced into the glass bottle using a funnel.

vii. Use one third of the vehicle to rinse the mortar and pestle by a triturating motion and

transfer the vehicle to the bottle.

viii. Use the remaining volume of vehicle to rinse the funnel.

ix. Shake the produced suspension well.

x. Label the bottle containing the produced suspension.

Calculations:

Amount of salicylic acid required for preparation 1: ________g

Amount of salicylic acid required for preparation 2: ________g

Joe Borg 1/1/2012 Borg Street Msida Age: 50 Rx Compound a 10mg/ml of suspension X

pt to take 50mg bd x5 days

Dr Borg Reg No 0000 Clinic Street Msida

PHR 4308

ASI/NB/MCZ/MZA 2012 12

Questions

1. What information should be included on the label of extemporaneous preparations?

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

_____________________________________________________________________

2. What is the shelf-life of the extemporaneous preparations produced?

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

_____________________________________________________________________

3. Why is the ointment slab used made of glass?

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

_____________________________________________________________________

4. What volume of suspension X should be taken daily?

_______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

Calculations:

Quantity of tablets X required: ________

Volume of suspension required: ________ml

Weight of sodium benzoate required: ________g

PHR 4308

ASI/NB/MCZ/MZA 2012 13

5. What type of tablets should not be used for the preparation of suspension? Why?

_______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________

6. Describe the ideal containers for the storage of extemporaneous ointments and syrups.

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

_____________________________________________________________________

REFERENCES

1. Roche®. Tamiflu® (oseltamivir) – Product information. [Online]. [cited 2012 Feb 1]. Available from: URL: http://www.roche-australia.com/fmfiles/re7229005/downloads/anti-virals/tamiflu-pi.pdf

Demonstrator Name Signature

PHR 4308

ASI/NB/MCZ/MZA 2012 14

Practical 3

Particle Size Distribution

Name: Group: Date:

Powders generally consist of particles with irregular shapes and non-uniform sizes. This

means that size distributions are often complex. Particle size is therefore described by

determining the number of particles in successive size ranges. The distribution is often

represented by a histogram in which the width of the bar represents the size range and the

height represents the frequency of occurrence in each range. A smooth curve can then be

drawn through the midpoints of the tops of the bars. A particle size distribution curve is

obtained in this way.

In order to obtain a distribution curve, the powder is separated into fractions depending on

particle size. The most frequently used method to separate powders is sieving. Basically,

this technique consists of placing a nest of sieves of different aperture on top of one another

with the finest aperture sieve being placed at the bottom and subsequent sieves being

placed in ascending degrees of coarseness. The sieves are then shaken mechanically or

electromagnetically. The sieve motion applied can be oriented horizontally which tends to

loosen the packing of the particles in contact with the sieve surface, or vertically which tends

to agitate and mix the particles.

Method

i. Accurately weigh each sieve to be used, to the nearest 0.1g.

ii. Set up the nest of sieves on the mechanical shaker in an ascending order i.e. the

finest sieve is at the bottom and the coarsest sieve is on top.

iii. Accurately weigh out approximately 25g, 50g and 100g of the powder.

iv. Place the first sample carefully on the topmost sieve and close the cover.

v. Shake the powder through the sieves at 50% amplitude for 5 minutes. Then clean

the sieves and repeat for each sample size so as to determine what sample size

should be used.

vi. Accurately weigh the approximate sample size to be tested. Clean and accurately

weigh once again each sieve.

vii. Place the sample on the top most sieve, close the lid and vibrate at 50% amplitude

until the end-point is reached. This is achieved when the weight held on each one of

the sieves does not change by more than 5% or 0.1g (or 20% if the weight on that

particular sieve is less than 5% of the test sample size).

viii. If any sieve is found to hold more than 50% of the test sample, then the test is to be

repeated with the inclusion of an additional sieve of intermediate coarseness

between this sieve and the next coarser one. You should repeat the test if more

than 5% of your sample is lost.

PHR 4308

ASI/NB/MCZ/MZA 2012 15

ix. Your report must include the total sieving time, the methodology used (Dry Sieving

Method) and the set values for all variable parameters.

Questions

1. Draw a histogram of your particle size distribution and a particle size distribution

curve. Comment on the shape of this curve.

Comment on the shape of this curve.

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

PHR 4308

ASI/NB/MCZ/MZA 2012 16

2. What is the finest particle size you would normally use this method for?

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

3. What problems can be encountered if the particle size is finer than this?

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

4. What is the commonest difficulty encountered when testing particle size by this

method? How can this problem be overcome?

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

5. What settings can be varied in this test?

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

6. How should sieves be cleaned?

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

PHR 4308

ASI/NB/MCZ/MZA 2012 17

7. If electrostatic charge is affecting your analysis, what corrective action should you

take?

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

Demonstrator Name Signature

PHR 4308

ASI/NB/MCZ/MZA 2012 18