+ All Categories
Home > Documents > Phase Sequence Indicator(Contact Type) - IC Master … 855PR.pdfST-850 855 PR 855 PRA 855 PRB...

Phase Sequence Indicator(Contact Type) - IC Master … 855PR.pdfST-850 855 PR 855 PRA 855 PRB...

Date post: 15-Mar-2018
Category:
Upload: dinhthuy
View: 220 times
Download: 1 times
Share this document with a friend
1
ST-850 855 PR 855 PRB 855 PRA FEATURES Two functions in one unit: open phase and phase sequence detection. Lamps let you determine at-a-glance if phase is open. Large size alligator clips for easy clipping onto switch-boards terminals. Checks a wide range of 3-phase power sources. Special test leads length are available on request. Push button switch is designed to minimize damage due to negligence. SPECIFICATIONS ST-850 855 PR Voltage 90V-600V AC 200V-600V AC Frequency response 50 / 60 Hz 50 / 60 Hz Operating temperature & humidity 0°C ~ 40°C at 80% Max. relative humidity Storage temperature & humidity -10°C ~ 50°C at 90% Max. relative humidity Cord 1.1m each of red(R), white(S) and black(T) cord Dimensions 134(L) × 85(W) × 45(D)mm Weight Approx. 510g Approx. 530g Safety standard IEC 1010 CAT II 600V EN 61010-1 CAT IV 600V EN 61326-1 Accessories Instruction manual Soft pouch ● Silicone wire 2m + Fuse + Alligator(AL-23 CA) ● EN 61010-1 CAT IV 600V EN 61326-1 Fuse Phase Sequence Indicator(Contact Type) 5F., NO.105, Jhongcheng Rd., Tucheng Dist., New Taipei City 23674, Taiwan (R.O.C.) TEL: 886-2-22681528 FAX: 886-2-22681529 e-mail: [email protected] www.sew.com.tw MEASURE WITH PRECISION
Transcript

ST-850 855 PR

855 PRB855 PRA

FEATURES ● Two functions in one unit: open phase and phase sequence detection. ● Lamps let you determine at-a-glance if phase is open. ● Large size alligator clips for easy clipping onto switch-boards terminals. ● Checks a wide range of 3-phase power sources. ● Special test leads length are available on request. ● Push button switch is designed to minimize damage due to negligence.

SPECIFICATIONSST-850 855 PR

Voltage 90V-600V AC 200V-600V ACFrequency response 50 / 60 Hz 50 / 60 HzOperating temperature& humidity 0°C ~ 40°C at 80% Max. relative humidity

Storage temperature& humidity -10°C ~ 50°C at 90% Max. relative humidity

Cord 1.1m each of red(R), white(S) and black(T) cordDimensions 134(L) × 85(W) × 45(D)mmWeight Approx. 510g Approx. 530g

Safety standard IEC 1010 CAT II 600V EN 61010-1 CAT IV 600VEN 61326-1

Accessories Instruction manualSoft pouch

● Silicone wire 2m + Fuse + Alligator(AL-23 CA)● EN 61010-1 CAT IV 600V EN 61326-1

Fuse

Phase Sequence Indicator(Contact Type)

5F., NO.105, Jhongcheng Rd., Tucheng Dist., New Taipei City 23674, Taiwan (R.O.C.)

TEL: 886-2-22681528FAX: 886-2-22681529

e-mail: [email protected]

MEASURE WITH PRECISION

Recommended