+ All Categories
Home > Documents > Photometrics 230V - Hacel Lighting...l TP(b) rated as standard 359 DLOR: 0.82 Transverse Axial...

Photometrics 230V - Hacel Lighting...l TP(b) rated as standard 359 DLOR: 0.82 Transverse Axial...

Date post: 29-Oct-2020
Category:
Upload: others
View: 2 times
Download: 0 times
Share this document with a friend
1
PRODUCT INFORMATION Tel: (0191) 280 9911 Email: [email protected] Web: www.hacel.co.uk SkyMod ® Grid LED 21W LED IM297 _ LED _ 21 1 359 33W LED IM297 _ LED _ 33 1 359 46W LED IM297 _ LED _ 46 1 359 K LG7 in accordance with SLL Code for Lighting 2012* l Features an Opal polycarbonate diffuser with wipe clean surface l Available in a choice of lumen outputs, delivering up to 8366 lumens l Efficacies up to 142 lm/W l 21W version has luminance limits below 3000cd/m 2 at the 65 O cut off * l Life expectancy in excess of 71,000 hours (L90 B10) l Colour stability within 3 MacAdams l Wide choice of high quality control gear l TP(b) rated as standard l Wireless Lighting Control available, see Connected video for full overview 359 DLOR: 0.82 Transverse Axial 0 o /180 o 90 o /270 o 66 54 593 x 593 34 159 82 230V 50Hz 44 I P 5.8 kg Designed for 15mm and 25mm T grid ceilings CRI 80 CRI 80 21W 3746 lm 0.82 80 22.3W 0.95 0.10A 15.0A (230us) 25.0A (140us) 137 lm/W 486 lm (13%) 21W 3880 lm 0.82 80 22.3W 0.95 0.10A 15.0A (230us) 25.0A (140us) 142 lm/W 504 lm (13%) 17W 33W 6182 lm 0.82 80 37.2W 0.95 0.17A 24.7A (268us) 28.0A (195us) 136 lm/W 494 lm (8%) 33W 6402 lm 0.82 80 37.2W 0.95 0.17A 24.7A (268us) 28.0A (195us) 141 lm/W 512 lm (8%) 17W 46W 8076 lm 0.82 80 48.0W 0.95 0.22A 25.9A (252us) 26.0A (264us) 137 lm/W 484 lm (6%) 46W 8366 lm 0.82 80 48.0W 0.95 0.22A 25.9A (252us) 26.0A (264us) 142 lm/W 501 lm (6%) 3 Warm White LED (3000K) Lumen Output LOR CRI Total Power Power Factor Running Current Inrush Current (Std) Inrush Current (Dim) Efficacy Emergency Output (BLF) 4 Neutral White LED (4000K) Lumen Output LOR CRI Total Power Power Factor Running Current Inrush Current (Std) Inrush Current (Dim) Efficacy Emergency Output (BLF) Photometrics Gear types F & G must be operated through a DSI A Integral Driver E Emergency F Digital Dim G Digital Dim + Emergency J Switch Dim K Switch Dim + Emergency S DALI Dim T DALI Dim + Emergency C DALI Dim + DALI Emergency L DALI Bluetooth M DALI Bluetooth + Emergency 3 Warm (3000K) 4 Neutral (4000K) 1 White (RAL 9010) Interconnection options available contact Sales
Transcript
Page 1: Photometrics 230V - Hacel Lighting...l TP(b) rated as standard 359 DLOR: 0.82 Transverse Axial 0o/180o 90o/270o SkyMod 54 66 593 x 593 34 159 82 34 159 82 87 7 598 x 598 575 x 569

PR

OD

UC

T IN

FO

RM

AT

IO

N

Tel: (0191) 280 9911 Email: [email protected] Web: www.hacel.co.uk

SkyMod® Grid

LED

21W LED IM297 _ LED _ 21 1 35933W LED IM297 _ LED _ 33 1 35946W LED IM297 _ LED _ 46 1 359

KKK K KK

LG7 in accordance with SLL Code for Lighting 2012*

l Features an Opal polycarbonate diffuser with wipe clean surfacel Available in a choice of lumen outputs, delivering up to 8366 lumensl Efficacies up to 142 lm/Wl 21W version has luminance limits below 3000cd/m2 at the 65O cut off *l Life expectancy in excess of 71,000 hours (L90 B10)l Colour stability within 3 MacAdamsl Wide choice of high quality control gearl TP(b) rated as standardl Wireless Lighting Control available, see Connected video for full overview

359 DLOR: 0.82

Transverse Axial 0o/180o 90o/270o

SkyMod

6654

593 x 593

34

159 82

34

159 82

87

7

598 x 598

575 x 569

61 55

676 x 626

600 x 550

230V50Hz 580 x 580mm20

I P6.5 kg

230V50Hz 44

I P5.8 kg

230V50Hz 600 x 550mm20

I P6.5 kg

Designed for 15mm and 25mm T grid ceilings

CRI 80

CRI 80

21W3746 lm0.828022.3W0.950.10A15.0A (230us)25.0A (140us)137 lm/W486 lm (13%)

21W3880 lm0.828022.3W0.950.10A15.0A (230us)25.0A (140us)142 lm/W504 lm (13%)17W

33W6182 lm0.828037.2W0.950.17A24.7A (268us)28.0A (195us)136 lm/W494 lm (8%)

33W6402 lm0.828037.2W0.950.17A24.7A (268us)28.0A (195us)141 lm/W512 lm (8%)17W

46W8076 lm0.828048.0W0.950.22A25.9A (252us)26.0A (264us)137 lm/W484 lm (6%)

46W8366 lm0.828048.0W0.950.22A25.9A (252us)26.0A (264us)142 lm/W501 lm (6%)

3 Warm White LED (3000K) Lumen Output LOR CRI Total Power Power Factor Running Current Inrush Current (Std) Inrush Current (Dim) Efficacy EmergencyOutput(BLF)

4 Neutral White LED (4000K) Lumen Output LOR CRI Total Power Power Factor Running Current Inrush Current (Std) Inrush Current (Dim) Efficacy EmergencyOutput(BLF)

Photometrics

Gear types F & G must be operated through a DSI

A Integral Driver E Emergency F Digital Dim G DigitalDim+Emergency J Switch Dim K SwitchDim+Emergency S DALI Dim T DALIDim+Emergency C DALIDim+DALIEmergency L DALIBluetooth M DALIBluetooth+Emergency

3 Warm (3000K) 4 Neutral (4000K)

1 White (RAL 9010)

Interconnection options available contact Sales

Recommended