80
Pipes and Fittings Imperial and Metric Systems MAY 2007
Transcript

The VKD ball valve with Dual Block®

technology is developed by FIP. The VKD provides an advanced

standard in valvedesign that standsup to the most

severe industrialapplication

requirements.

VKD Valve

Dedicated pipework system for compressed air.

Specialist pipework system for the transfer of fuel.

Purpose designed system for safe chemical drainage.

Ideal for chilled, condensate and cold water systems.

Versatile general purpose pipework - the establishedmaterial for handling of chemicals and water up to 60ºC.

Excellent resistance to acids, at temperatures up to 95ºC.

Handles a wide range of aggressive chemicalsat high temperature.

At the forefront of development and manufacture ofthermoplastic pipework for over half a century, Durapipe pipesystems are widely used in industries around the world.

• Fully matched systems

• Wide range of flow controls

• Comprehensive technical support

• Unsurpassed range of approvals

... don’t take a chance with any other brand

Complete system solutionsfor industrial applications

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:04 pm Page 2

email: [email protected] web: www.durapipe.co.uk 3

Index

Durapipe PVC-U Introduction..................................................4-7

Index to PVC-U Imperial Fittings ................................................8Pipe ........................................................................................10Sockets plain ...........................................................................11‘O’ Ring sockets plain ...............................................................11Repair sockets plain .................................................................11Reducing bushes plain..............................................................12Reducing sockets plain .............................................................12Elbows 45° plain......................................................................12Elbows 90° plain......................................................................13Saddles plain...........................................................................13Tees 45° plain .........................................................................13Tees 90° plain .........................................................................13Tees 90° reducing ....................................................................14Bends 221⁄2° long radius...........................................................14Bends 45° long radius plain ......................................................14Bends 90° long radius plain ......................................................14Bends 90° short radius plain.....................................................15End caps plain.........................................................................15Socket unions plain ..................................................................15Imperial/metric socket adaptors..................................................16Sockets plain/BSP threaded ......................................................16Elbows 90° plain/BSP threaded.................................................16Reducing bushes plain/BSP threaded .........................................17Adaptors female/male plain/BSP threaded ..................................17Adaptors male/female plain/BSP threaded ..................................17Male threaded fittings ...............................................................18Female threaded fittings ............................................................18Hexagon nipples male plain/BSP threaded..................................18Barrel nipples plain/BSP threaded .............................................18Hose adaptors male/BSP threaded - short pattern.......................18Hose adaptors male/BSP threaded - long pattern ........................18Hose adaptors female BSP threaded ..........................................19Tank connectors plain/BSP threaded ..........................................19Composite unions plain/BSP threaded female brass ....................19Composite unions plain/BSP threaded male brass .......................20Sockets BSP threaded ..............................................................20Reducing bushes BSP threaded .................................................20Reducers BSP threaded, reduced spigot/socket......................20-21Elbows 45° BSP threaded .........................................................21Elbows 90° BSP threaded .........................................................21Tees 90° equal.........................................................................22End caps BSP threaded ............................................................22Plugs BSP threaded .................................................................22Hexagon nipples BSP threaded..................................................22Back nuts BSP threaded ...........................................................23Unions BSP threaded/EPDM seals .............................................23Flanges stub serrated ...............................................................23Flanges full face plain/drilled.....................................................24Flanges blanking plain/drilled ....................................................25Backing rings galvanised mild steel drilled .................................26Gaskets flat stub flange EPDM...................................................27Gaskets full face drilled EPDM...................................................27Valve support plates galvanised mild steel drilled........................28

Valves VKD Double union ball valves ....................................................29TK 3-way valves.......................................................................29VX Double union ball valves ......................................................30SK Single union ball valves........................................................30SR Single union ball check valves ..............................................30VA Air release valves.................................................................31RV Y type strainers ...................................................................31VM Diaphragm valves ...............................................................31FK Butterfly valves ...................................................................32PR Pressure relief valves ...........................................................32

One-step solvent cement and Eco-cleaner ...................................33Cobra pipe clips .......................................................................33Saddle clips .............................................................................33

Index to PVC-U Metric Fittings .................................................34Pipe ........................................................................................36Sockets ...................................................................................36Reducing bushes ......................................................................37Reducers .................................................................................38Elbows 45°..............................................................................38Elbows 90°..............................................................................39Tees 45° equal .........................................................................39Tees 90° equal .........................................................................39Tees 90° reducing.....................................................................40Cross ......................................................................................40Bends 90° ...............................................................................40End Caps plain ........................................................................40Socket unions ..........................................................................41Imperial/metric socket adaptors..................................................41Sockets ...................................................................................42Reducers ............................................................................42-43Male threaded adaptors ............................................................43Elbows 90°.........................................................................43-44Tees 90°..................................................................................44Tees 90° equal .........................................................................45Male threaded adaptors ............................................................45Female threaded adaptors .........................................................46Hose adaptors BSP female thread .............................................46Hose adaptors BSP male thread ................................................46Hose adaptors spigot end..........................................................47Saddle clamps .........................................................................47Tank connectors .......................................................................47Female composite unions ..........................................................47Male composite unions .............................................................48Stub flanges serrated face .........................................................48Flanges full face .......................................................................48Backing rings ...........................................................................49Flat gaskets/stub flanges ...........................................................50Valve support plates .................................................................50

Valves VKD Double union ball valves ....................................................51TK 3-way valves.......................................................................51VX Double union ball valves ......................................................52SK Single union ball valves........................................................52SR Single union ball check valves ..............................................52VA Air release valves.................................................................52RV Y type strainers ...................................................................53VM Diaphragm valves ...............................................................53PR Pressure relief valves ...........................................................53FK Butterfly valves ...................................................................54

One-step solvent cement and Eco-cleaner ...................................55Cobra pipe clips .......................................................................55

Technical Information ..............................................................56Maximum pressure/temperature relationship................................56Flow calculations......................................................................57Fittings....................................................................................57Flow nomogram .......................................................................58Pipe routing .............................................................................59Calculating expansion and contraction ........................................59

Additional Important Information ..............................................63

Durapipe PVC-U Jointing Guide................................................64Drying times ............................................................................66Branch connections ..................................................................67The use of bushes and reducers.................................................68Threaded connections ...............................................................69Tightening torques for flange bolts in PVC-U piping systems .........69

Comparison of PVC-U Imperial and Metric Sized Pipe ................70

General Information.................................................................71

Product Specification (Imperial)................................................74

Product Specification (Metric) ..................................................75

Durapipe UK Pipework Systems ...............................................76

Conditions of Sale ...................................................................79

page page

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:04 pm Page 3

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 2794504

Durapipe PVC-U – the proven industrial pipework systemcombining corrosion resistance, toughness and economy

Durapipe PVC-U The right choice for process

chemicals and industrial fluid handling

Excellent chemical resistance, easy

handling and simple installation have

helped establish Durapipe PVC-U as the

leading material for process chemicals

and industrial fluid handling.

We offer a completely matched range of

pipes, fittings and flow control equipment

in both Imperial and Metric systems.

This catalogue serves to help you achieve

a safe, high integrity, long lasting system.

Environment and ConservationThe energy used to make Durapipe PVC-Uthermoplastic pipe from raw material comparesfavourably with, for example, steel pipemanufacture because lower conversiontemperatures are needed. Furthermore, ourprocesses are clean with low process emissions.

Durapipe PVC-U pipe and fittings are cheaperand easier to transport because they are lighterin weight than the equivalent metal pipes. Theycan be recycled at the end of life into otherproducts, and scrap during the manufacturingprocess can also be recycled and re-used. This minimises the need for any thermoplasticpipe scrap entering the waste stream.

Durapipe UK operates an environmentalmanagement system that has been successfullyassessed against BS EN ISO 14001environmental management system standard.

Installation CostAs well as influencing systemperformance, pipework accounts for alarge proportion of the total installationcost making the right choice of pipesand pipe fittings vital. Durapipe PVC-Ucan help reduce installation costs.

Corrosion ResistanceThe inherent susceptibility to corrosionand thermal properties of metal pipingmaterials such as copper and steel areoften not suited to arduous applications.

The corrosion resistance of the pipingmaterial is vitally important since thechemicals used in many industrialprocesses are of a highly corrosivenature. Durapipe PVC-U has a proventrack record in such situations.

ApplicationsThe following is a list of applications for

Durapipe PVC-U pipework systems:

• Acids

• Alkalis

• Treated effluent

• Untreated effluent

• Cooling water

• Potable water

• Flocculants

• General chemical dosing

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:04 pm Page 4

email: [email protected] web: www.durapipe.co.uk 5

Intr

odu

ctio

n

Major UsersThe following companies are all majorusers of Durapipe PVC-U pipeworksystems:

• Autoglym

• Biwater Treatment

• Brimar Plastics

• Britannia Zinc

• Boots

• Dewey Waters

• Ford Motor Company

• ICL

• Memcor

• Nestlé

• npower

• Pennine Foods

• PowerGen

• Rolls-Royce

• Severn Trent Water

• Statham Engineering

• Thurnall Engineering Plastics

• Wessex Water

• Yorkshire Water

Supplementary ServicesWe offer the following supplementary services:

• Technical advice regarding use of all

Durapipe UK products.

• Installed cost comparison.

• Product and application training seminars.

Technical SupportOur experience and expertise is at your

disposal. Our Technical Support team will be

pleased to offer you installation advice.

AvailabilityDurapipe PVC-U pipework is available from an

extensive international network of distributors

and stockists. Please ask for details of your

nearest outlet.

LightweightAt one-sixth the weight of steel systems,Durapipe PVC-U is much easier to handle,especially during installation at site.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:04 pm Page 5

email: [email protected] web: www.durapipe.co.uk 11

Imp

eria

l Fi

ttin

gs

Sockets plain

Size PN A B Z1 gms Code3⁄8 15 21 32 2 5 02 100 1011⁄2 15 26 38 2 8 02 100 1023⁄4 15 32 43 3 16 02 100 1031 15 41 50 3 30 02 100 10411⁄4 15 52 60 4 46 02 100 10511⁄2 15 60 66 2 81 02 100 1062 15 74 78 4 147 02 100 10721⁄2 15 88 94 4 250 12 100 3123 15 104 105 3 325 02 100 1094 15 136 135 5 768 02 100 1105 15 171 163 7 1240 12 100 3166 15 190 192 12 1884 02 100 1128 9 257 249 11 4732 02 100 11310 9 308 309 10 5800 02 100 11412 9 362 343 13 9800 02 100 115

‘O’ ring sockets plain

PressureSize PN A B C Z1 Class gms Code

2 12 74 78 27 4 D 142 02 305 1073 12 108 104 37 4 D 460 02 305 1094 12 136 132 49 6 D 790 02 305 1106 9 201 191 74 8 C 3017 02 305 1128 6 255 248 94 14 B 4140 02 305 113

‘O’ rings EPDMNot end load resistant - for buried pipework only.

PressureSize A B C Class gms Code

2 12 74 77 49 D 141 02 307 10721⁄2 9 93 94 64 C 293 02 307 1083 12 107 104 78 D 456 02 307 1094 12 136 131 101 D 760 02 307 1105 9 173 165 129 C 1760 02 307 1116 9 201 192 152 C 2965 02 307 1128 6 256 249 199 B 4100 02 307 113

‘O’ rings EPDMNot end load resistant - for repair of buried pipework only.

Repair sockets plain

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:04 pm Page 11

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945012

Reducing bushes plain

Size PN B Z1 gms Code1⁄2 x 3⁄8 15 17 2 9 02 109 1213⁄4 x 1⁄2 15 20 3 10 02 109 1221 x 1⁄2 15 23 6 30 02 109 1231 x 3⁄4 15 24 4 20 02 109 124

*11⁄4 x 1⁄2 15 28 12 28 02 109 116*11⁄4 x 3⁄4 15 28 8 32 02 109 11711⁄4 x 1 15 28 5 26 02 109 125

*11⁄2 x 1⁄2 15 30 13 34 02 109 118*11⁄2 x 3⁄4 15 30 10 35 02 109 119*11⁄2 x 1 15 30 7 51 02 109 12611⁄2 x 11⁄4 15 31 4 25 02 109 127*2 x 3⁄4 15 38 15 59 02 109 120*2 x 1 15 38 15 59 02 109 128*2 x 11⁄4 15 38 11 76 02 109 1292 x 11⁄2 15 37 7 54 02 109 130

21⁄2 x 2 15 44 8 97 02 109 131*3 x 11⁄2 15 51 21 175 02 109 134*3 x 2 15 51 15 229 02 109 1353 x 21⁄2 15 50 6 162 02 109 136

*4 x 3 15 65 12 357 02 109 1415 x 4 15 78 15 548 02 329 142

*6 x 4 15 93 27 859 02 109 1476 x 5 12 90 13 850 02 329 148

*8 x 6 9 110 23 1500 02 109 15210 x 8 9 140 25 3500 02 109 15112 x 10 9 165 25 4100 02 109 153

*Relief configuration (see drawing insert).

Size PN A B C Z1 gms Code3⁄4 x 1⁄2 15 32 44 26 7 14 02 114 1221 x 3⁄4 15 41 53 33 9 27 02 114 124

11⁄4 x 1 15 52 63 41 10 50 02 114 12511⁄4 x 11⁄4 15 59 68 51 8 75 02 114 127

2 x 11⁄2 15 74 82 59 12 129 02 114 1303 x 2 15 108 114 75 26 413 02 114 1354 x 3 15 136 136 108 20 720 02 114 1416 x 4 15 205 213 140 55 2548 02 114 1478 x 6 9 256 263 198 50 4400 02 114 152

Reducing sockets plain

Elbows 45° plain

Size PN A C Z1 gms Code3⁄8 15 21 20 6 11 02 119 1011⁄2 15 27 26 8 12 02 119 102

3⁄4 15 33 33 12 20 02 119 1031 15 41 37 13 36 02 119 10411⁄4 15 52 44 15 76 02 119 10511⁄2 15 60 50 18 111 02 119 1062 15 82 66 27 206 02 119 10721⁄2 15 90 63 17 320 12 119 3123 15 112 94 40 1015 02 119 1094 15 139 115 50 1735 02 119 1105 15 173 115 37 1660 12 119 3166 15 198 134 41 3080 02 119 1128 9 259 182 65 7250 02 119 113

10 9 307 206 66 9800 02 119 11412 9 363 243 78 15500 02 119 115

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:04 pm Page 12

email: [email protected] web: www.durapipe.co.uk 13

Imp

eria

l Fi

ttin

gs

Elbows 90° plain

Size PN A C Z1 gms Code3⁄8 15 21 24 9 8 02 115 1011⁄2 15 26 29 12 14 02 115 102

3⁄4 15 32 34 14 24 02 115 1031 15 41 41 17 45 02 115 10411⁄4 15 52 49 21 90 02 115 10511⁄2 15 60 56 26 130 02 115 1062 15 74 68 31 246 02 115 10721⁄2 15 90 83 38 450 12 115 3123 15 111 104 52 930 02 115 1094 15 137 125 61 1271 02 115 1105 15 173 153 76 2080 12 115 3166 15 199 177 84 3640 02 115 1128 9 256 251 112 8900 02 115 113

10 9 307 286 146 13300 02 115 11412 9 363 340 175 20300 02 115 115

Saddles plain

Size PN A B E Z1 gms Code

2 x 11⁄4 15 60 136 48 33 116 02 126 1293 x 11⁄2 15 76 140 60 46 204 02 126 1344 x 2 15 95 140 74 58 305 02 126 1406 x 2 15 71 154 73 86 300 02 126 146

Two saddles can be mounted diametrically opposite.

Tees 45° plain

Size PN A B C Z1 Z2 Z3 gms Code

1⁄2 9 28 68 44 34 27 7 36 02 128 1023⁄4 9 33 81 52 41 32 8 56 02 128 1031 9 41 97 63 49 39 9 95 02 128 10411⁄4 9 50 117 80 61 52 10 250 02 128 10511⁄2 9 60 140 97 80 67 12 384 02 128 1062 9 74 170 113 90 73 15 704 02 128 107

Tees 90° plain

Size PN A B C Z1 gms Code3⁄8 15 21 49 25 10 9 02 122 1011⁄2 15 26 58 29 11 17 02 122 1023⁄4 15 32 69 34 15 30 02 122 1031 15 41 83 42 19 56 02 122 10411⁄4 15 52 101 50 23 118 02 122 10511⁄2 15 59 113 53 25 170 02 122 1062 15 74 137 70 31 321 02 122 10721⁄2 15 90 172 87 36 605 12 122 3123 15 113 204 105 44 1195 02 122 1094 15 143 246 127 55 1720 02 122 1105 15 172 307 153 72 4150 12 122 3166 15 199 352 172 84 4900 02 122 1128 9 257 468 240 100 12400 02 122 113

10 9 306 573 287 148 18600 02 122 11412 9 363 680 340 175 27200 02 122 115

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:04 pm Page 13

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945014

Bends 221/2° long radius

Size PN C E R gms Code

1 15 76 38 102 50 02 311 10411⁄2 15 110 57 152 148 02 311 1062 15 113 73 203 285 02 311 1073 15 202 114 305 858 02 311 1094 15 262 152 407 1804 02 311 1106 15 385 229 610 5993 02 311 112

Tolerance on angle ±3°

Bends 45° long radius plain

Size PN C E R gms Code

1 15 75 37 102 77 02 310 10411⁄2 15 113 55 152 204 02 310 1062 15 152 73 203 316 02 310 1073 15 238 121 305 1080 02 310 1094 15 300 145 407 2235 02 310 1106 15 440 218 610 7340 02 310 112

Tolerance on angle ±3°

Bends 90° long radius plain

Size PN C E R gms Code

3 15 403 98 305 1510 02 309 1094 15 545 138 407 3350 02 309 1106 15 817 207 610 11000 02 309 112

Tolerance on angle ±3°

Tees 90° reducing

Size PN A B C D Z1 gms Code

3⁄4 x 1⁄2 15 32 64 32 26 17 22 02 124 122

1 x 1⁄2 15 40 70 36 26 17 40 02 124 123

1 x 3⁄4 15 40 76 38 32 20 41 02 124 124

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 14

email: [email protected] web: www.durapipe.co.uk 15

Imp

eria

l Fi

ttin

gs

Bends 90° short radius plain

Size PN A C Z1 gms Code

1⁄2 15 26 56 43 26 02 118 1023⁄4 15 33 65 45 60 02 118 103

1 15 40 85 63 86 02 118 104

11⁄4 15 51 108 81 175 02 118 105

11⁄2 15 62 134 102 360 02 118 106

2 15 73 165 126 755 02 118 107

21⁄2 15 93 195 150 1100 12 118 312

3 15 111 226 172 1907 02 118 109

4 15 140 280 216 3168 02 118 110

End caps plain

Size PN A B gms Code Fig

3⁄8 15 21 17 4 02 140 101 11⁄2 15 26 22 7 02 140 102 13⁄4 15 32 25 12 02 140 103 1

1 15 40 30 26 02 140 104 1

11⁄4 15 52 51 42 02 140 105 2

11⁄2 15 59 39 62 02 140 106 1

2 15 74 70 116 02 140 107 2

21⁄2 15 94 59 250 12 149 312 1

3 15 109 97 343 02 140 109 2

4 15 136 120 600 02 140 110 2

6 15 189 171 1650 02 140 112 1

Socket unions plain

Size PN A B Z1 Z2 gms Code

3⁄8 15 38 44 5 10 35 02 205 1011⁄2 15 46 49 5 10 50 02 205 1023⁄4 15 52 55 5 10 73 02 205 103

1 15 63 65 7 12 115 02 205 104

11⁄4 15 72 77 10 14 163 02 205 105

11⁄2 15 80 92 13 16 215 02 205 106

2 15 101 112 15 19 395 02 205 107

21⁄2 15 135 107 8 13 610 12 205 312

3 9 155 113 6 4 975 02 205 109

4 9 180 138 7 6 1500 02 205 110

EPDM seal as standardFor FPM seal order by type 204

FIG.1

FIG.2

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 15

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945016

Imperial/metric socket adaptors plain

Size PN A B Z1 gms Code

1⁄2 x 20 15 27 35 3 12 33 345 1023⁄4 x 25 15 33 41 3 22 33 345 103

1 x 32 15 41 47 3 44 33 345 104

11⁄4 x 40 15 50 55 2 65 33 345 105

11⁄2 x 50 15 61 65 4 125 33 345 106

2 x 63 15 76 79 5 210 33 345 107

3 x 90 15 108 107 6 438 33 345 109

4 x 110 15 131 131 4 852 33 345 110

6 x 160 15 198 185 7 1700 33 345 112

Sockets plain/BSP threaded

Size PN A B C Z1 gms Code

1⁄2 12 27 38 17 4 11 02 101 1023⁄4 12 33 44 20 2 18 02 101 103

1 12 42 51 23 5 39 02 101 104

11⁄4 12 52 55 22 4 59 02 101 105

11⁄2 12 60 61 26 2 83 02 101 106

2 12 75 70 29 2 147 02 101 107

21⁄2 12 90 92 30 18 260 33 101 108

3 12 110 107 52 3 488 02 101 109

Elbows 90° plain/BSP threaded

Size PN A C Z1 gms Code

1⁄2 12 26 34 17 35 02 116 1023⁄4 12 32 36 20 51 02 116 103

1 12 40 41 23 80 02 116 104

11⁄4 12 55 50 27 140 02 116 105

11⁄2 12 62 57 30 175 02 116 106

2 12 75 66 35 261 02 116 107

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 16

email: [email protected] web: www.durapipe.co.uk 17

Imp

eria

l Fi

ttin

gs

Reducing bushes plain/BSP threaded

Size PN B Z1 gms Code1⁄2 x 3⁄8 12 17 6 5 02 111 1213⁄4 x 1⁄2 12 20 5 9 02 111 1221 x 3⁄4 12 23 6 15 02 111 124

Adaptors female/male plain/BSP threaded

Size PN A B D Z1 gms Code3⁄8 12 22 35 10 20 7 02 151 1011⁄2 12 27 45 12 28 12 02 151 1023⁄4 12 35 48 14 28 18 02 151 103

Size PN A B D Z1 gms Code

1 12 46 58 19 35 48 02 151 10411⁄4 12 56 66 22 38 80 02 151 10511⁄2 12 72 75 22 43 150 02 151 1062 12 80 85 26 46 200 02 151 107

Adaptors male/female plain/BSP threaded

Size PN A B Z1 gms Code1⁄2 12 27 38 16 10 02 153 1023⁄4 12 36 44 18 18 02 153 1031 12 43 50 21 31 02 153 10411⁄4 12 55 60 22 63 02 153 10511⁄2 12 63 66 25 88 02 153 1062 12 78 78 29 167 02 153 107

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 17

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945018

Hexagon nipples male plain/BSP threaded

Size PN A B D gms Code3⁄8 12 24 36 11 10 02 107 1011⁄2 12 30 42 15 16 02 107 1023⁄4 12 36 48 16 40 02 107 1031 12 46 56 20 50 02 107 10411⁄4 12 46 60 21 60 02 107 10511⁄2 12 55 63 22 80 02 107 1062 12 72 74 26 123 02 107 107

Barrel nipples plain/BSP threaded

Size PN B D gms Code

3 9 129 31 300 02 316 1094 9 153 37 560 02 316 110

PVC nipples are made from Durapipe PVC-U pipes.

Hose adaptors male BSP threaded - short pattern

Size PN B D gms Code

1⁄2 x 13 12 61 13 10 02 157 1023⁄4 x 20 12 65 16 19 02 157 103

1 x 27 12 73 18 37 02 157 104

Male threaded fittings plain/brass male thread

Female threaded fittings plain/brass female thread

Size D D1 l z SW Code

1⁄2 x 1⁄2 35 29 55 40 36 02 228 1023⁄4 x 3⁄4 43 34 58 42 44 02 228 103

1 x 1 50 43 66 48 51 02 228 104

11⁄4 x 11⁄4 62 52 74 53 63 02 228 105

Size D D1 l z SW Code1⁄2 x 1⁄2 35 29 40 11 36 02 229 1023⁄4 x 3⁄4 43 34 42 11 44 02 229 103

1 x 1 50 43 48 12 51 02 229 104

11⁄4 x 11⁄4 62 55 54 13 63 02 229 105

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 18

email: [email protected] web: www.durapipe.co.uk 19

Imp

eria

l Fi

ttin

gs

Hose adaptors male BSP threaded - long pattern

Size PN B D gms Code1⁄4 x 12 x 14 15 56 11.0 7 93 157 6003⁄8 x 16 x 18 15 58 11.4 14 93 157 6021⁄2 x 20 x 22 15 66 15.0 19 93 157 6053⁄4 x 25 x 27 15 81 16.3 30 93 157 6081 x 30 x 32 15 97 19.1 45 93 157 61211⁄4 x 40 x 42 15 104 21.4 85 93 157 61611⁄2 x 50 x 52 15 111 21.4 120 93 157 6232 x 60 x 64 15 123 25.7 180 93 157 630

Hose adaptors female BSP threaded - loose nut with EPDM gasket

Tank connectors plain/BSP threaded EPDM gasket

Size PN A B C D F gms Code

1⁄2 12 28 70 38 29 16 34 02 235 1023⁄4 12 33 76 38 32 20 39 02 235 103

1 12 46 102 55 42 24 110 93 235 104

11⁄4 12 50 120 65 44 32 154 93 235 105

11⁄2 12 59 165 70 61 37 207 93 235 106

2 12 79 153 93 59 49 358 93 235 107

3 12 105 204 129 90 760 656 93 235 109

Composite unions plain/BSP threaded female brass

Size PN A B Z1 Z2 gms Code

1⁄2 15 40 42 3 7 165 02 212 1023⁄4 15 48 49 3 9 290 02 212 103

1 15 55 59 11 12 310 02 212 104

11⁄4 15 65 68 9 10 450 02 212 105

11⁄2 15 79 75 12 14 800 02 212 106

2 15 88 90 14 14 950 02 212 107

Fitted with brass retaining nut and EPDM rubber seal.

Size PN L H gms Code

*1⁄2 x 12 x 14 15 14.0 56 15 93 156 601*3⁄4 x 16 x 18 15 11.5 60 24 93 156 603

*1 x 20 x 22 15 11.0 67 35 93 156 606*11⁄4 x 25 x 27 15 14.0 81 55 93 156 609*11⁄2 x 30 x 32 15 16.0 97 80 93 156 613*2 x 40 x 42 15 18.0 104 140 93 156 616*21⁄4 x 50 x 52 15 17.5 111 200 93 156 623*21⁄2 x 60 x 64 15 20.0 123 300 93 156 312*23⁄4 x 60 x 64 15 20.0 123 300 93 156 630

* Thread size designation

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 19

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945020

Sockets BSP threaded

Size PN A B gms Code

1⁄2 12 26 38 16 02 102 1023⁄4 12 33 43 28 02 102 103

1 12 41 51 44 02 102 104

11⁄4 12 51 54 77 02 102 105

11⁄2 12 62 63 112 02 102 106

2 12 75 72 170 02 102 107

21⁄2 12 90 91 275 93 102 108

3 12 110 107 564 02 102 109

4 12 130 127 665 93 102 110

Reducing bushes BSP threaded

Size PN A B D gms Code

1⁄2 x 3⁄8 12 24 25 10 7 02 113 1213⁄4 x 1⁄2 12 30 27 11 10 02 113 122

1 x 3⁄4 12 36 31 12 19 02 113 124

11⁄4 x 1 12 52 34 15 30 93 113 125

11⁄2 x 11⁄4 12 58 35 14 30 93 113 127

2 x 11⁄2 12 70 40 19 72 93 113 130

Male thread taper. Female thread parallel.

Reducers BSP threaded, reduced spigot/socket

Size PN A B D Z1 gms Code

3⁄4 x 1⁄2 12 36 41 15 16 22 93 174 122

1 x 3⁄4 12 46 45 16 19 42 93 174 124

11⁄4 x 1 12 55 55 19 21 55 93 174 125

11⁄2 x 11⁄4 12 65 62 21 21 102 93 174 127

2 x 11⁄2 12 80 69 21 26 165 93 174 130

21⁄2 x 2 12 95 81 26 30 210 93 174 131

3 x 21⁄2 12 110 93 30 33 360 93 174 136

4 x 3 12 129 106 33 39 500 93 174 141

Composite unions plain/BSP threaded male brass

Size PN A B Z1 gms Code

1⁄2 15 40 54 3 175 02 217 1023⁄4 15 48 74 3 320 02 217 103

1 15 55 86 8 420 02 217 104

11⁄4 15 65 94 10 620 02 217 105

11⁄2 15 78 108 13 1000 02 217 106

2 15 88 129 15 1200 02 217 107

Fitted with brass retaining nut and EPDM rubber seal.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 20

email: [email protected] web: www.durapipe.co.uk 21

Imp

eria

l Fi

ttin

gs

Reducers BSP threaded, reduced socket

Size PN H L1 L E K Fig gms Code

1⁄2 x 3⁄8

3⁄4 x 3⁄8

3⁄4 x 1⁄2

1 x 3⁄8

1 x 1⁄2

1 x 3⁄4

11⁄4 x 1⁄2

11⁄4 x 3⁄4

11⁄4 x 111⁄2 x 1⁄2

11⁄2 x 3⁄411⁄2 x 111⁄2 x 11⁄4

2 x 3⁄4

2 x 12 x 11⁄4

2 x 11⁄2

21⁄2 x 23 x 23 x 21⁄2

4 x 3

Elbows 45° BSP threaded

Size PN A C Z1 gms Code1⁄2 12 28 22 7 18 93 120 1023⁄4 12 33 24 8 24 93 120 1031 12 41 30 11 45 93 120 10411⁄4 12 50 36 15 68 93 120 10511⁄2 12 64 42 21 140 93 120 1062 12 76 52 26 255 93 120 10721⁄2 12 90 62 31 345 93 120 1083 12 107 72 39 625 93 120 109

Elbows 90° BSP threaded

Size PN A C Z1 gms Code1⁄2 12 26 29 17 35 02 117 1023⁄4 12 32 33 19 53 02 117 1031 12 41 41 23 84 02 117 10411⁄4 12 55 51 25 149 02 117 10511⁄2 12 63 57 30 181 02 117 1062 12 75 67 35 273 02 117 10721⁄2 12 90 85 49 450 93 117 1083 12 107 98 61 835 93 117 1094 12 130 119 75 1135 93 117 110

Fig A

Fig B

151515151515151515151515151515151515151515

353639414446484952525055576063656556666679

11.411.415.011.415.016.315.016.319.115.016.319.121.416.319.121.421.425.725.730.233.3

15.016.316.319.119.119.121.421.421.421.421.421.421.425.725.725.725.730.233.333.339.3

2834344040405252525858585870707070----

2328283535354444445151515164646464809393118

AAAAAAAAAAAAAAAAABBBB

10121520242537374046475254808085102155185200500

93 173 12193 173 16493 173 12293 173 16693 173 12393 173 12493 173 11693 173 11793 173 12593 173 11893 173 11993 173 12693 173 12793 173 12093 173 12893 173 12993 173 13093 173 13193 173 13593 173 13693 173 141

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 21

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945022

Tees 90° equal BSP threaded

Size PN A B C Z1 gms Code3⁄8 12 22 46 23 8 18 93 125 1011⁄2 12 27 54 27 11 25 93 125 1023⁄4 12 35 66 33 14 46 93 125 1031 12 43 81 40 20 76 93 125 10411⁄4 12 50 96 49 22 117 93 125 10511⁄2 12 61 116 61 34 260 93 125 1062 12 76 143 70 42 465 93 125 10721⁄2 12 90 169 88 51 640 93 125 1083 12 109 199 103 63 1135 93 125 1094 12 133 245 130 80 1710 93 125 110

End caps BSP threaded

Size PN A B D gms Code3⁄8 12 26 20 16 7 02 141 1011⁄2 12 27 20 16 8 02 141 1023⁄4 12 36 23 17 13 02 141 1031 12 44 28 21 23 02 141 10411⁄4 12 55 31 22 42 02 141 10511⁄2 12 63 35 25 65 02 141 1062 12 78 40 28 116 02 141 1073 12 111 65 53 338 02 141 109

Plugs BSP threaded

Size PN A B D gms Code3⁄8 12 11 19 10 4 02 155 1011⁄2 12 13 23 14 7 02 155 1023⁄4 12 14 28 15 10 02 155 1031 12 17 30 17 16 02 155 10411⁄4 12 22 35 22 39 02 155 10511⁄2 12 27 38 22 46 02 155 1062 12 37 45 26 64 02 155 107

Hexagon nipples BSP threaded

Size PN A B D gms Code3⁄8 12 24 38 14 9 02 106 1011⁄2 12 30 46 18 15 02 106 1023⁄4 12 36 50 19 38 02 106 1031 12 46 59 13 50 02 106 10411⁄4 12 46 67 27 65 02 106 10511⁄2 12 55 73 29 100 02 106 1062 12 72 81 33 175 02 106 10721⁄2 12 80 78 30 150 93 106 1083 12 76 85 33 225 93 106 1094 12 120 97 39 380 93 106 110

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 22

email: [email protected] web: www.durapipe.co.uk 23

Imp

eria

l Fi

ttin

gs

Back nuts BSP threaded

Size PN A B C gms Code3⁄8 12 25 11 29 6 02 159 1011⁄2 12 28 13 38 10 02 159 1023⁄4 12 33 13 38 19 02 159 1031 12 45 16 54 24 02 159 10411⁄4 12 50 18 58 25 02 159 10511⁄2 12 60 19 69 39 02 159 1062 12 79 21 91 83 02 159 107

Unions BSP threaded/EPDM seals

Size PN A B Z1 Z2 gms Code3⁄8 12 33 40 5 10 22 93 203 1011⁄2 12 41 46 5 13 35 93 203 1023⁄4 12 50 51 6 16 65 93 203 1031 12 58 57 6 17 85 93 203 10411⁄4 12 72 65 7 19 145 93 203 10511⁄2 12 79 65 7 18 180 93 203 1062 12 98 78 8 24 325 93 203 107

Flanges stub serratedSize PN A B D Z1 gms Code

2 15 96 40 14 3 115 02 135 10721⁄2 15 106 49 10 4 165 12 135 3123 15 127 57 18 6 265 02 135 1094 15 159 69 20 6 465 02 135 1105 15 180 83 14 7 700 12 135 3166 12 213 104 24 11 1100 02 135 1128 9 269 132 26 14 2700 02 135 113

*10 9 326 155 29 8 3450 02 139 114*12 9 378 178 33 9 5060 02 139 115

*Taper back flange (see drawing insert).

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 23

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945024

Flanges full face plain/drilled

Drilled to BS10:1962 – Table ENo. of Hole

Size PN A B D Z1 P.C.D. Holes Diameter gms Code1⁄2 15 96 21 10 4 67 4 14 88 02 130 1023⁄4 15 105 24 10 4 73 4 14 101 02 130 1031 15 115 27 10 4 83 4 14 137 02 130 10411⁄4 15 140 33 10 5 87 4 14 157 02 130 10511⁄2 15 150 37 10 5 98 4 14 198 02 130 1062 15 166 45 10 6 115 4 18 287 02 130 1073 15 199 60 11 8 145 4 18 513 02 130 109*4 15 220 72 14 6 178 8 18 823 02 130 1106 12 284 98 22 8 235 8 22 1730 02 130 112

*4" BS10 Table D has 4 holes and should be ordered as 02 317 110.

Drilled to BS4504: Table 10/3 and Table 16/3No. of Hole

Size PN A B D Z1 P.C.D. Holes Diameter gms Code1⁄2 15 96 21 10 4 65 4 14 88 02 319 1023⁄4 15 105 24 10 4 75 4 14 101 02 319 1031 15 115 27 10 4 85 4 14 137 02 319 10411⁄4 15 140 33 10 5 100 4 18 157 02 319 10511⁄2 15 150 37 10 5 110 4 18 198 02 319 1062 15 166 45 10 6 125 4 18 287 02 319 1073 15 199 60 11 8 160 8 18 513 02 319 1094 15 220 72 14 6 180 8 18 823 02 319 1106 12 284 98 22 8 240 8 22 1730 02 319 112

Drilled to ANSI Class 150No. of Hole

Size PN A B D Z1 P.C.D. Holes Diameter gms Code1⁄2 15 96 21 10 4 60 4 14 88 02 322 1023⁄4 15 105 24 10 4 70 4 14 101 02 322 1031 15 115 27 10 4 80 4 14 137 02 322 10411⁄2 15 150 37 10 5 98 4 14 198 02 322 1062 15 166 45 10 6 121 4 18 287 02 322 1073 15 199 60 11 8 152 4 18 513 02 322 1094 15 220 72 14 6 190 8 18 823 02 322 1106 12 284 98 22 8 241 8 22 1730 02 322 112

Size PN A B D Z1 gms Code

1⁄2 15 96 21 10 4 96 02 129 1023⁄4 15 105 24 10 4 110 02 129 103

1 15 115 27 10 4 143 02 129 104

11⁄4 15 140 33 10 4 168 02 129 105

11⁄2 15 150 37 10 5 207 02 129 106

2 15 166 45 11 6 300 02 129 107

3 15 199 60 11 8 530 02 129 109

4 15 220 72 14 6 842 02 129 110

6 12 284 98 22 8 1817 02 129 112

Undrilled

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 24

email: [email protected] web: www.durapipe.co.uk 25

Imp

eria

l Fi

ttin

gs

Flanges blanking plain/drilled

Drilled to BS10:1962 – Table ENo. of Hole

Size PN A B P.C.D. Holes Diameter gms Code2 15 165 13 115 4 18 300 02 313 1073 15 197 19 145 4 18 690 02 313 1094 15 214 19 178 8 18 950 02 313 1106 15 286 26 235 8 22 2100 02 313 1128 12 337 26 292 8 22 3020 02 313 113

No. of HoleSize PN A B P.C.D. Holes Diameter gms Code2 15 165 13 125 4 18 300 02 323 1073 15 197 19 160 8 18 690 02 323 1094 15 214 19 180 8 18 950 02 323 1106 15 286 26 240 8 22 2100 02 323 1128 12 337 26 295 12 22 3020 02 323 113

No. of HoleSize PN A B P.C.D. Holes Diameter gms Code2 15 165 13 121 4 18 300 02 325 1073 15 197 19 152 4 18 690 02 325 1094 15 214 19 190 8 18 950 02 325 1106 15 286 26 241 8 22 2100 02 325 1128 12 337 26 298 8 22 3020 02 325 113

Size PN A B gms Code

1 15 116 13 160 02 131 10411⁄2 15 150 13 250 02 131 1062 15 165 13 300 02 131 1073 15 197 20 690 02 131 1094 15 214 19 950 02 131 1106 15 286 26 2100 02 131 1128 12 337 26 3020 02 131 113

Undrilled

Drilled to ANSI Class 150

Drilled to BS4504:Table 16/3 (1/2" to 8") 10/3 (1/2" to 6")

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 25

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945026

Drilled to BS4504:Table 16/3 (1/2" to 12") 10/3 (1/2" to 6")(P) No. of Bolt

Size A B C D P.C.D. Holes Size gms Code1⁄2 95 6 35 14 65 4 M12x50 350 03 421 1023⁄4 106 6 45 14 75 4 M12x50 410 03 421 103

1 114 6 50 14 85 4 M12x50 490 03 421 104

11⁄4 141 6 60 18 100 4 M16x50 730 03 421 105

11⁄2 150 6 67 18 110 4 M16x50 820 03 421 106

2 165 8 79 18 125 4 M16x65 1220 03 421 107

21⁄2 185 8 92 18 145 4 M16x65 1480 13 421 312

3 200 8 112 18 160 8 M16x70 1500 03 421 109

4 220 8 139 18 180 8 M16x80 1680 03 421 110

5 250 10 167 18 210 8 M16x90 1940 13 421 316

6 285 10 196 22 240 8 M20x90 2700 03 421 112

8+ 340 10 256 22 295 12 M20x100 3230 03 421 113

10 405 15 308 26 355 12 M24x130 5740 03 403 114

12 460 20 364 26 410 12 M24x150 8580 03 407 115

Drilled to ANSI Class 150(P) No. of Bolt

Size A B C D P.C.D. Holes Size gms Code1⁄2 89 6 35 14 60 4 M12x50 190 03 425 1023⁄4 98 6 45 14 70 4 M12x50 230 03 425 103

1 108 6 50 14 80 4 M12x50 290 03 425 104

11⁄4 117 6 60 14 90 4 M12x50 300 03 425 105

11⁄2 127 6 67 14 98 4 M12x50 360 03 425 106

2 152 8 79 18 121 4 M16x65 790 03 425 107

3 190 8 112 18 152 4 M16x65 1240 03 425 109

4 229 9 139 18 190 8 M16x70 1560 03 425 110

6 279 11 196 22 241 8 M20x90 2730 03 425 112

8 343 12 256 22 298 8 M20x100 3340 03 425 113

Backing rings galvanised mild steel drilled

Drilled to BS10:1962 – Table E(P) No. of Bolt

Size A B C D P.C.D. Holes Size gms Code1⁄2 95 6 35 19 67 4 M12x50 210 03 416 1023⁄4 102 6 45 14 73 4 M12x50 230 03 416 103

1 114 6 50 14 83 4 M12x50 290 03 416 104

11⁄4 121 6 60 14 87 4 M12x50 290 03 416 105

11⁄2 133 7 67 14 98 4 M12x50 370 03 416 106

2 152 8 79 18 115 4 M16x65 590 03 416 107

3 184 8 112 18 145 4 M16x70 1060 03 416 109

*4 216 8 139 18 178 8 M16x80 1190 03 416 110

6 279 10 196 21 235 8 M20x90 2160 03 416 112

8 337 10 256 21 292 8 M20x100 2800 03 416 113

10 405 15 308 22 356 12 M20x130 5500 03 407 114

12 460 20 364 26 410 12 M24x150 8580 03 407 115

*4" BS10 Table D has 4 holes and should be ordered as 03 415 110. The bore of the 10" and12" backing rings is machined to mate with the taper of the stub flanges.

+ Not for use with FK Butterfly valve, use 8 hole backing ring code 04 996 131

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 26

email: [email protected] web: www.durapipe.co.uk 27

Imp

eria

l Fi

ttin

gs

Gaskets flat stub flange EPDM

Size A B gms Code

2 97 3.0 21 03 431 10721⁄2 106 3.0 22 13 411 3123 128 3.0 23 03 431 1094 160 3.9 36 03 431 1105 180 4.0 60 13 411 3166 214 3.9 74 03 431 1128 269 4.0 92 03 431 113

10 327 4.1 186 03 411 11412 378 3.9 218 03 411 115

Gaskets full face drilled EPDM

Drilled to BS10:1962 – Table ENo. of Hole

Size A B P.C.D. Holes Diameter gms Code1⁄2 95 3.0 67 4 14 31 03 410 1023⁄4 112 3.0 73 4 14 37 03 410 1031 115 3.0 83 4 14 37 03 410 10411⁄4 121 3.0 87 4 14 41 03 410 10511⁄2 133 3.0 98 4 14 55 03 410 1062 153 3.0 115 4 18 56 03 410 1073 184 3.0 145 4 18 98 03 410 109*4 216 3.2 178 8 18 112 03 410 1106 280 3.1 235 8 22 160 03 410 112

*4" BS10 Table D has 4 holes and should be ordered as 03 409 110.

Drilled to BS4504 Table 10/3 and Table 16/3

Drilled to ANSI Class 150No. of Hole

Size A B P.C.D. Holes Diameter gms Code1⁄2 95 3.0 60 4 14 31 03 426 1023⁄4 112 3.0 70 4 14 37 03 426 1031 115 3.0 80 4 14 37 03 426 10411⁄2 133 3.0 98 4 14 55 03 426 1062 153 3.0 121 4 18 56 03 426 1073 184 3.0 152 4 18 98 03 426 1094 216 3.2 190 8 18 112 03 426 1106 280 3.1 241 8 22 160 03 426 112

No. of HoleSize A B P.C.D. Holes Diameter gms Code1⁄2 95 3.0 65 4 14 31 03 408 1023⁄4 112 3.0 75 4 14 37 03 408 1031 115 3.0 85 4 14 37 03 408 10411⁄4 121 3.0 100 4 18 41 03 408 10511⁄2 133 3.0 110 4 18 55 03 408 1062 153 3.0 125 4 18 56 03 408 1073 184 3.0 160 8 18 98 03 408 1094 216 3.2 180 8 18 112 03 408 1106 280 3.1 240 8 22 160 03 408 112

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 27

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945028

Valve support plates galvanised mild steel drilled

Size B C E L M N gms Code1⁄2 95 86 50 14 16 2 370 03 458 1023⁄4 106 89 75 14 16 2 450 03 458 103

1 143 99 75 14 16 2 560 03 458 104

11⁄4 152 105 75 14 16 2 950 03 458 105

11⁄2 151 105 74 14 16 2 1150 03 458 106

2 166 127 101 14 17 2 1380 03 458 107

21⁄2 185 144 125 14 22 2 2500 31 459 312

3 201 143 127 14 22 2 1650 03 458 109

4 222 161 151 14 24 3 2550 03 458 110

6 286 217 228 14 33 3 4100 03 458 112

8 340 242 280 14 31 3 6250 03 458 113

N = No. of holes in base.For details of flange drillings see the corresponding backing ring.

Drilled to BS4504:Table 16/3 (1/2" to 8") 10/3 (1/2" to 6")

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 28

email: [email protected] web: www.durapipe.co.uk 29

Imp

eria

l Fi

ttin

gs

VALVES

VKD Double union ball valves Manual – EPDM seals

d DN *PN L Z H H1 E B B1 C C1 g Code

16-3/8" 10 16 14 75 103 65 54 54 29 67 40 215 H0 DKE 10120-1/2" 15 16 16 71 103 65 54 54 29 67 40 205 H0 DKE 10225-3/4" 20 16 19 77 115 70 65 65 34.5 85 49 330 H0 DKE 10332-1" 25 16 22 84 128 78 73 69.5 39 85 49 438 H0 DKE 10440-11/4" 32 16 26 94 146 88 86 82.5 46 108 64 693 H0 DKE 10550-11/2" 40 16 31 102 164 93 98 89 52 108 64 925 H0 DKE 10663-2" 50 16 38 123 199 111 122 108 62 134 76 1577 H0 DKE 107

with BS series plain female ends for solvent welding

TK 3-way valves Plain EPDM L Port

Position 1 Position 2 Position 3 Position 4 Operation 0º 90º 180º 270°

L Diverting and isolating

T Diverting or mixing

= flow

d DN PN C C1 C2 B B1 B2 gms Code

3/8 10 16 83.5 29.5 54 87.5 33 50 350 HO TKE 1011/2 15 16 83.5 29.5 54 87.5 33 50 350 HO TKE 1023/4 20 16 98 35.5 62.5 98.5 39 56.5 600 HO TKE 103

1 25 16 105 37 68 106 45 61.5 850 HO TKE 104

11/4 32 16 139.5 51 88.5 135 51 76.5 1350 HO TKE 105

11/2 40 16 139.5 51 88.5 139 57 80.5 1750 HO TKE 106

2 50 16 154 51 103 159 69 97.5 2950 HO TKE 107

d DN PN E H H1 L Z

3/8 10 16 55 118 80 14 901/2 15 16 55 118 80 16 863/4 20 16 66 145 100 19 107

1 25 16 75 160 110 22 116

11/4 32 16 87 188.5 131 26 136.5

11/2 40 16 100 219 148 31 157

2 50 16 122 266.5 179 38 190.5

d DN PN Z L H H1 E B B1 C C1 gms Code

21/2 65 16 147 44 235 133 164 164 87 225 175 4380 H0 DKE 312

3 80 16 168 51 270 149 203 177 105 327 272 7200 H0 DKE 313

4 100 16 186 61 308 167 238 195 129 385 330 11141 H0 DKE 314

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 29

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945030

VX Double union ball valves Manual – EPDM seals

d DN PN L Z H E B C gms Code1/2 15 16 16.5 49 82 53 50.0 65 145 H0 VXE 1023/4 20 16 19.0 53 91 62 58.0 76 220 H0 VXE 1031 25 16 22.5 58 103 71 65.0 85 315 H0 VXE 10411/4 32 16 26.0 68 120 84 76.0 100 505 H0 VXE 10511/2 40 16 30.0 79 139 98 85.5 112 725 H0 VXE 1062 50 16 36.0 102 174 117 103.0 137 1245 H0 VXE 10721/2 65 10 44.0 128 216 154 133.0 222 2600 H0 VXE 1083 80 10 50.5 143 244 189 154.0 270 4330 H0 VXE 109

with BS series plain female ends for solvent welding

SK Single union ball valves EPDM seals

d DN PN L L1 Z H E E1 B C gms Code1/2 15 16 16.5 16.5 59.0 92 55 28 49 66 140 H0 SKE 1023/4 20 16 19.0 19.5 70.5 109 66 36 58 75 240 H0 SKE 1031 25 16 22.5 22.5 73.0 118 75 42 66 85 325 H0 SKE 10411/4 32 16 26.0 27.0 80.0 133 87 53 76 97 510 H0 SKE 10511/2 40 16 30.0 31.0 91.0 152 100 61 86 110 680 H0 SKE 1062 50 16 36.0 39.0 108.0 183 122 76 100 134 1180 H0 SKE 107

with BS series plain female ends for solvent welding

SR Single union ball check valves Plain ends – EPDM seals

with BS series plain female ends for solvent welding

d DN PN E L Z H gms Code1/2 15 16 55 16 86 102 110 H0 SRE 1023/4 20 16 66 19 105 124 205 H0 SRE 1031 25 16 75 22 127 149 310 H0 SRE 10411/4 32 16 87 26 146 172 475 H0 SRE 10511/2 40 16 100 31 156 187 660 H0 SRE 1062 50 16 120 38 186 224 1120 H0 SRE 107

Note - Also available with BS series plain female ends

with metric series end

Note: this valve must be installed at a minimum distance of 10 x nominal diameter (eg. 20" for size 2") from pump flange.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 30

email: [email protected] web: www.durapipe.co.uk 31

Imp

eria

l Fi

ttin

gs

VA Air release valves Plain ends – EPDM seals

with BS parallel threaded female end

d DN PN E L Z H gms Code

1/2 15 16 55 15.0 93 123 120 H0 VAE 1023/4 20 16 66 16.3 113.4 146 205 H0 VAE 103

1 25 16 75 19.1 135.8 174 360 H0 VAE 104

11/4 32 16 87 21.4 157.2 200 475 H0 VAE 105

11/2 40 16 100 21.4 166.2 209 670 H0 VAE 106

2 50 16 120 25.7 196.6 248 1130 H0 VAE 107

RV Y type strainers Socket union ends – EPDM seals

d DN PN A B E L Z H K gms Code

Grey Trans. max

1/2 15 15 15 125 72 55 16 103 135 - 211 H0 UVE 1023/4 20 15 15 145 84 66 19 120 158 - 358 H0 UVE 103

1 25 15 15 165 95 75 22 132 176 - 526 H0 UVE 104

11/4 32 15 10 190 111 87 26 155 207 - 733 H0 UVE 105

11/2 40 15 10 210 120 100 31 181 243 - 1095 H0 UVE 106

2 50 15 10 240 139 120 38 222 298 - 1843 H0 UVE 107

Grey or Transparentwith BS series plain female ends for solvent welding

VM Diaphragm valves manual – plain spigot ends EPDM

d DN PN B B1 H h H1 I J L gms Code

1/2 15 10 95 26 124 12 90 25 M6 16 700 H0 VME 2023/4 20 10 95 26 144 12 90 25 M6 19 700 H0 VME 203

1 25 10 95 26 154 12 90 25 M6 23 700 H0 VME 204

11/4 32 10 126 40 174 18 115 44.5 M8 27 1500 H0 VME 205

11/2 40 10 126 40 194 18 115 44.5 M8 32 1500 H0 VME 206

2 50 10 148 40 224 18 140 44.5 M8 39 2400 H0 VME 207

21/2 65 10 225 55 284 23 215 100 M12 44 7000 H0 VME 208

3 80 10 225 55 300 23 215 100 M12 51 7000 H0 VME 209

4 100 10 295 69 350 23 250 120 M12 - 10500 H0 VME 210

BS series plain male ends

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 31

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945032

PR Pressure relief valves EPDM seals

with BS series male ends for solvent welding

d PN Z A B C D E F G kg Code

1⁄2 10 92 143 26 35 124 M6 25 12 0.7H0 PRE 202

3⁄4 10 106 143 26 35 144 M6 25 12 0.7H0 PRE 203

1 10 108 143 26 35 154 M6 25 12 0.7H0 PRE 204

11⁄4 10 120 204 40 50 174 M8 44.5 16 1.5H0 PRE 205

11⁄2 10 130 204 40 50 194 M8 44.5 16 1.5H0 PRE 206

2 10 146 219 40 50 224 M8 44.5 16 2.4H0 PRE 207

Options: FPM diaphragm

FK Butterfly valves – FPM or EPDM seals

d DN PN B2 B3 C C1 g U Code

11/2 40 16 60 137 175 100 900 4 H0 FKE 1062 50 16 70 143 175 100 1080 4 H0 FKE 10721/2 65 10 80 164 272 110 1470 4 H0 FKE 1083 80 10 93 178 272 110 1870 8 H0 FKE 1094 100 10 107 192 272 110 2220 8 H0 FKE 1105 125 10 120 212 330 110 3100 8 H0 FKE 1116 150 10 134 225 330 110 3850 8 H0 FKE 1128 200 10 161 272 420 122 6750 8 H0 FKE 113

Sizes 6" to 12" are available with gearbox operation.10" and 12" are available, contact 01543 272424 for more details.

Actuated Valves and Flow ControlThe valves in this catalogue are only a selection of the complete range of

thermoplastic valves available.

Durapipe UK offer a comprehensive range of actuated valves with either

pneumatic or electric actuators. These are assembled at our in-house

actuation department and meet the demands of a wide range of

applications found in industrial pipework installations.

To further complement the Durapipe UK valve offering, there is a complete

range of Flow Meters, Solenoid Valves and the flow control system

FLOW X3/CHEM X3.

For further information on any of these products, please do not hesitate to

contact your local Area Sales Manager or our Valves and Flow Control

Department on 01543 272424.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 32

email: [email protected] web: www.durapipe.co.uk 33

Imp

eria

l Fi

ttin

gs

Cobra pipe clips polypropylene

Size A B C D G Bolt/Screw size gms Code

3⁄8 – 35 25 19 16 M.4/3BA/No 8 7 13 434 3051⁄2 – 35 30 14 16 M.5/1BA/No 10 8 13 434 3063⁄4 – 35 35 16 17 M.5/1BA/No 10 11 13 434 307

1 – 40 40 17 17 M.5/1BA/No 10 14 13 434 308

11⁄4 75 45 45 20 20 M.5/1BA/No 10 21 13 434 309

11⁄2 85 50 50 22 21 M.6/0BA/No 10 30 13 434 310

2 102 60 60 19 21 M.6/0BA/No 10 42 13 434 311

21⁄2 122 70 70 27 31 M.8 94 13 434 312

3 148 80 90 39 31 M.8 121 13 434 313

4 171 90 96 36 35 M.8 185 13 434 314

5 211 156 132 40 40 M.8 252 13 434 316

6 243 170 150 40 40 M.8 185 13 434 317

Clips 11/4" and above are fitted with a pipe retaining strap.Bolts/screws not supplied.

Saddle clips polypropylene

Size C E F G Bolt/Screw size gms Code

3⁄8 13 37 – 14 M.4/3BA/No 8 3 03 455 1011⁄2 18 41 – 14 M.4/3BA/No 8 4 03 455 1023⁄4 21 45 – 16 M.5/2BA/No 10 6 03 455 103

1 23 56 – 16 M.5/2BA/No 10 7 03 455 104

11⁄4 29 65 – 16 M.5/2BA/No 10 11 03 455 105

11⁄2 34 67 – 16 M.5/2BA/No 10 12 03 455 106

2 38 87 – 22 M.6/0BA/No 12 25 03 455 107

3 50 122 8 34 M.10/3⁄8UNC 45 03 455 109

4 65 156 13 38 M.10/3⁄8UNC 70 03 455 110

Backing plate shown dotted supplied with 3" and 4" only. Bolts/screws notsupplied. Bolt holes in 3" and 4" clips are not countersunk.

One-step solvent cement and Eco-cleaner

Cement Cleaner Code CodeLitres gms gms PVC-U cement Eco-cleaner

0.5 500 500 03 462 395 03 457 3951.0 1100 – 03 462 396 –

Durapipe PVC-U solvent cement must be used for jointing of Durapipe PVC-U pipework systems.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 33

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945034

Index to PVC-U Metric Fittings

Pipe (plain)page 36

Bends 90°page 40

Tees 45° equalpage 39

Saddle clampspage 47

Flanges full facepage 48

Sockets page 36

Reducing bushes page 37

Elbows 45°page 38

Elbows 90°page 39

Tees 90° equalpage 39

Caps, plainpage 40

Socket unionspage 41

Adaptor fittings - Socketspage 42

Adaptor fittings -Reducerspages 42-43

Crosspage 40

Reducerspage 38

Hose adaptors BSP female threadpage 46

Hose adaptors BSP male thread page 46

Tank connectorspage 47

Tees 90° reducingpage 40

Imperial/metric socket adaptorspage 41

Female threaded adaptorspage 46

Adaptor fittings - Male threaded adaptors page 43

Adaptor fittings - Elbows 90°page 43-44

Adaptor fittings - Tees 90°page 44

Adaptor fittings - Tees 90° equalpage 45

Male threaded adaptorspage 45

Male composite unionspage 48

Female compositeunions page 47

Flat gaskets/stub flangespage 50

Backing ringspage 49

Valve support platespage 50

Hose adaptors spigot endpage 47

Stub flanges serrated facepage 48

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 34

email: [email protected] web: www.durapipe.co.uk 35

Met

ric

Fitt

ings

One-step solvent cementand Eco-cleaner page 55

SK Single union ball valvespage 52

SR Single union ball check valves page 52

VX Double union ballvalves (manual)page 52

VKD Double union ball valves (manual)page 51

VA Air release valvespage 52

VM Diaphragm valvespage 53

PR Pressure relief valvespage 53

FK Butterfly valvespage 54

RV Y type strainerspage 53

VALVES

TK 3-way valves page 51

Cobra clipspage 55

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 35

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945036

d1

Size t kg/m SL Code20 1.7 0.13 5 33 560 30625 2.1 0.20 5 33 560 30732 2.7 0.34 5 33 560 30840 3.2 0.51 5 33 560 30950 4.0 0.79 5 33 560 31063 5.0 1.25 5 33 560 311

Pipe 16 bar

Sockets

Size PN A B Z1 gms Code

12 16 17 27 3 3 33 100 30416 16 21 31 3 7 33 100 30520 16 26 35 3 11 33 100 30625 16 32 41 2 20 33 100 30732 16 40 47 3 30 33 100 30840 16 50 55 3 55 33 100 30950 16 61 65 3 90 33 100 31063 16 76 79 3 160 33 100 31175 16 90 91 3 250 33 100 31290 16 108 106 4 415 33 100 313

110 16 131 130 8 715 33 100 314125 16 145 145 7 960 33 100 315140 16 164 160 8 1240 33 100 316160 16 186 181 9 1680 33 100 317200 16 232 223 11 3050 33 100 318225 16 260 249 11 4600 33 100 319250 10 286 272 10 5760 33 100 320280 10 320 302 10 7630 33 100 321315 10 355 339 11 9780 33 100 323

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 36

email: [email protected] web: www.durapipe.co.uk 37

Met

ric

Fitt

ings

Fig. B Fig. A

Reducing bushes

Size PN B Z1 Fig gms Code

16 x 12 16 14 2 A 1 33 109 41020 x 16 16 18 2 A 3 33 109 41225 x 20 16 22 3 A 5 33 109 41532 x 20 16 28 6 A 15 33 109 41832 x 25 16 25.5 3.5 A 10 33 109 41940 x 20 16 35 9 B 25 33 109 42140 x 25 16 33 7 B 24 33 109 42240 x 32 16 30 4 A 17 33 109 42350 x 25 16 33 13 B 29 33 109 42550 x 32 16 39.5 8.5 B 35 33 109 42650 x 40 16 36 5 A 32 33 109 42763 x 32 16 38 16 B 73 33 109 43063 x 40 16 38 11.5 B 75 33 109 43163 x 50 16 38 7 A 65 33 109 43275 x 50 16 44 13 B 120 33 109 43775 x 63 16 44 6 A 85 33 109 43890 x 50 16 51 20 B 200 33 109 44290 x 63 16 51 13 B 210 33 109 44390 x 75 16 51 7 A 150 33 109 444

110 x 50 16 64 31 B 320 33 109 448110 x 63 16 61 23 B 340 33 109 449110 x 75 16 61 17 B 360 33 109 450110 x 90 16 61 9 A 270 33 109 451125 x 110 16 69 8 A 285 33 109 459140 x 90 16 76 25 B 730 33 109 465140 x 110 16 76 17 A 645 33 109 466140 x 125 16 76 9.5 A 350 33 109 467160 x 90 16 86 35 B 1040 33 109 473160 x 110 16 86 24 B 945 33 109 474160 x 140 16 86 10 A 565 33 109 476200 x 160 16 110 21 B 109 33 109 487225 x 160 16 119 33 B 1840 33 109 495225 x 200 16 119 13 A 1380 33 109 496250 x 160 10 132 45 B 4250 33 109 497250 x 200 10 132 25 A 3820 33 109 498250 x 225 10 132 12 A 2230 33 109 499280 x 225 10 147 27 B 4300 33 109 500280 x 250 10 147 15 A 2500 33 109 501315 x 225 10 165 45 B 8100 33 109 502315 x 250 10 165 33 B 5080 33 109 503315 x 280 10 165 18 A 4590 33 109 504

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 37

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945038

Reducers

Sized3 x d2 x d1 PN B Z1 gms Code

16 x 12 16 30 4 7 33 114 41020 x 16 16 35 5 8 33 114 30525 x 20 x 16 16 38.5 8.5 9 33 114 41225 x 20 x 20 16 40.5 8.5 12 33 114 30632 x 25 x 20 16 46 11 16 33 114 41532 x 25 x 25 16 49 11 20 33 114 30740 x 32 x 20 16 52 14 23 33 114 41840 x 32 x 25 16 55 14 27 33 114 41940 x 32 x 32 16 58 14 34 33 114 30850 x 40 x 20 16 60 18 36 33 114 42150 x 40 x 25 16 63 18 40 33 114 42250 x 40 x 32 16 66 18 48 33 114 42350 x 40 x 40 16 70 18 55 33 114 30963 x 50 x 25 16 73 23 75 33 114 42563 x 50 x 32 16 76 23 80 33 114 42663 x 50 x 40 16 80 23 90 33 114 42763 x 50 x 50 16 85 23 110 33 114 31075 x 63 x 50 16 93 24 130 33 114 43275 x 63 x 63 16 100 24 175 33 114 31190 x 75 x 40 16 100 30 160 33 114 43690 x 75 x 50 16 105 30 185 33 114 43790 x 75 x 63 16 112 30 225 33 114 43890 x 75 x 75 16 118 30 255 33 114 312

110 x 90 x 50 16 119 37 260 33 114 442110 x 90 x 63 16 126 37 300 33 114 443110 x 90 x 75 16 132 37 345 33 114 444110 x 90 x 90 16 139 37 400 33 114 313160 x 110 16 186 – 1270 33 114 474

Elbows 45°

Size PN A C Z1 gms Code

12 16 17 16 3 5 33 119 30416 16 21 20 5 6 33 119 30520 16 28 21.5 5.5 20 33 119 30625 16 33 25 6 26 33 119 30732 16 41 29.5 7.5 45 33 119 30840 16 50 36.5 10.5 70 33 119 30950 16 61 42.5 11.5 120 33 119 31063 16 76 52 14 200 33 119 31175 16 90 61 17 320 33 119 31290 16 107 72.5 21.5 550 33 119 313

110 16 130 87 26 915 33 119 314125 16 147 100 31 1315 33 119 315140 16 163 110 34 1660 33 119 316160 16 192 124 38 3060 33 119 317200 10 230 156 48 4500 33 119 318225 10 260 176 55 6400 33 119 319250 10 286 189 58 7700 33 119 320280 10 320 208 62 10460 33 119 321315 10 359 230 66 15500 33 119 323

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 38

email: [email protected] web: www.durapipe.co.uk 39

Met

ric

Fitt

ings

Elbows 90°

Size PN A C Z1 gms Code

12 16 17 20 8 4 33 115 30416 16 22 23 9 11 33 115 30520 16 26 28 12 15 33 115 30625 16 32 34 15 30 33 115 30732 16 40 41 19 50 33 115 30840 16 50 48 22 90 33 115 30950 16 61 58.5 27.5 160 33 115 31063 16 76 71.5 33.5 290 33 115 31175 16 91 85 41 450 33 115 31290 16 108 98.5 47.5 680 33 115 313

110 16 130 122 61 1180 33 115 314125 16 148 133 64 1650 33 115 315140 16 163 153 77 2080 33 115 316160 16 193 175 89 2980 33 115 317200 16 229 206 100 5360 33 115 318225 16 258 290.5 171.5 8700 33 115 319250 10 287 319 188 12480 33 115 320280 10 325 357 210 17000 33 115 321315 10 359 400 236 23370 33 115 323

Tees 90° equalSize PN A B C Z1 gms Code

12 16 16 39 20 8 6 33 122 30416 16 22 46 23 9 15 33 122 30520 16 27 54 27 11 25 33 122 30625 16 33 66 33 14 40 33 122 30732 16 40 80 40 18 65 33 122 30840 16 50 96 48 22 114 33 122 30950 16 61 116 58 27 185 33 122 31063 16 76 144 72 34 380 33 122 31175 16 91 169 84.5 40.5 605 33 122 31290 16 109 199 99.5 48.5 985 33 122 313110 16 133 244 122 61 1760 33 122 314125 16 151 266 133 64 2430 33 122 315140 16 174 306 153 77 4150 33 122 316160 16 193 348 174 88 5250 33 122 317200 16 228 414 207 101 6810 33 122 318225 16 258 466 233 114 12680 33 122 319250 10 286 518 259 128 13250 33 122 320280 10 319 580 290 144 17840 33 122 321315 10 360 652 326 162 25300 33 122 323

Tees 45° equal plain

Size PN A B C Z1 Z2 Z3 gms Code

20 16 28 68 45 7 36 29 40 33 418 30625 16 34 81 55 7 43 36 60 33 418 30732 16 41 97 66 9 53 44 105 33 418 30840 16 50 117 80 11 65 54 175 33 418 30950 16 60 139 96 12 77 65 255 33 418 31063 16 73 170 118 14 94 80 420 33 418 311

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 39

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945040

Tees 90° reducing

Size PN A B C D Z1 gms Code

25 x 25 x 20 16 33 66 30 28 14 37 33 124 41532 x 32 x 20 16 41 79 34 28 18 60 33 124 41832 x 32 x 25 16 41 79 37 34 18 65 33 124 41940 x 40 x 20 16 50 96 38 29 22 100 33 124 42140 x 40 x 25 16 50 96 41 34 22 100 33 124 42240 x 40 x 32 16 50 96 44 42 22 105 33 124 42350 x 50 x 20 16 61 116 43 30 27 160 33 124 42450 x 50 x 25 16 61 116 46 35 27 160 33 124 42550 x 50 x 32 16 61 116 49 42 27 165 33 124 42650 x 50 x 40 16 61 116 53 51 27 170 33 124 42763 x 63 x 25 16 76 143 53 36 34 290 33 124 42963 x 63 x 32 16 76 143 56 43 34 295 33 124 43063 x 63 x 40 16 76 143 60 52 34 300 33 124 43163 x 63 x 50 16 76 143 65 62 34 315 33 124 432

Cross

Size PN E L Z1 gms Code

25 16 35 19 14 60 33 108 30732 16 43 22 18 105 33 108 30840 16 52 26 23 75 33 108 30950 16 64 31 27 265 33 108 31063 16 79 38 34 505 33 108 311

Bends 90°

Size PN A C Z1 gms Code

20 16 27 56.5 40.5 35 33 118 30625 16 33 69 50 55 33 118 30732 16 41 87.5 65.5 100 33 118 30840 16 50 106.5 80.5 175 33 118 30950 16 61 131.5 100.5 280 33 118 31063 16 76 165 127 515 33 118 31175 16 94 194 150 1100 33 118 31290 16 112 229 178 1750 33 118 313110 16 136 208 147 2280 33 118 314

*160 10 189 293 207 5020 33 118 317

Caps plain

Size PN A B gms Code

12 16 17 15 3 33 140 30416 16 21 17 4 33 140 30520 16 28 23 9 33 140 30625 16 34 27 15 33 140 30732 16 41 31 25 33 140 30840 16 51 36 40 33 140 30950 16 62 43 60 33 140 31063 16 77 51 110 33 140 31175 16 91 59 190 33 140 31290 16 110 69 330 33 140 313110 16 133 85 575 33 140 314160 16 192 128 1900 33 140 317225 10 260 163 3000 33 140 319

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 40

email: [email protected] web: www.durapipe.co.uk 41

Met

ric

Fitt

ings

Socket unions

Size PN A B Z1 Z2 gms Code

12 16 28 38 3 10 15 33 205 30416 16 33 41 3 10 20 33 205 30520 16 41 45 3 10 35 33 205 30625 16 50 51 3 10 60 33 205 30732 16 58 57 9 10 85 33 205 30840 16 72 67 10 12 150 33 205 30950 16 79 79 12 14 175 33 205 31063 16 98 98 14 18 320 33 205 31175 10 135 107 8 13 720 33 205 31290 6 157 115 7 4 980 33 205 313

110 6 183 138 8 7 1480 33 205 314

EPDM seal as standardFor FPM seal order by type 204

Imperial/metric socket adaptors

Size PN A B Z1 gms Code

*1⁄2 x 20 15 27 35 3 12 33 345 102*3⁄4 x 25 15 33 41 3 22 33 345 103*1 x 32 15 41 47 3 44 33 345 104*11⁄4 x 40 15 50 55 2 65 33 345 105*11⁄2 x 50 15 61 65 4 125 33 345 106*2 x 63 15 76 79 5 210 33 345 107*3 x 90 15 108 107 6 438 33 345 109*4 x 110 15 131 128 4 852 33 345 110*6 x 160 15 198 185 7 1700 33 345 112

*Sizes shown in inch n.b. designation.

Solvent welded fittings - Socket unions plain socket/female BSP thread

d x R PN R1 L L1 H Z E gms Code

16 x 3/8 16 3/4 14 11.4 41.0 15.6 33 22 33 202 30520 x 1/2 16 1 16 15.0 45.0 14.0 41 35 33 202 30625 x 3/4 16 11/4 19 16.3 51.0 15.7 50 62 33 202 30732 x 1 16 11/2 22 19.1 57.0 15.9 58 85 33 202 30840 x 11/4 16 2 26 21.4 67.0 19.6 72 45 33 202 30950 x 11/2 16 21/4 31 21.4 72.0 19.6 79 180 33 202 31063 x 2 16 23/4 38 25.7 88.0 24.0 98 315 33 202 31175 x 21/2 10 31/2 44 30.2 108.0 34.0 123 643 33 202 31290 x 3 6 4 51 33.3 124.0 40.0 140 859 33 202 313110 x 4 6 5 61 39.3 138.0 38.0 165 1240 33 202 314

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 41

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945042

Adaptor fittings - Sockets plain/female BSP thread

d x R PN L L1 Z E K gms Code

16 x 3/8 16 14 11.4 5.5 23.5 24 12 33 101 101

20 x 1/2 16 16 15.0 4.0 28.5 29 20 33 101 102

25 x 3/4 16 19 16.3 5.0 35.0 35 30 33 101 103

32 x 1 16 22 19.1 6.0 43.0 43 48 33 101 104

40 x 11/4 16 26 21.4 5.0 50.0 50 56 33 101 105

50 x 11/2 16 31 21.4 8.0 61.0 61 102 33 101 106

63 x 2 16 38 25.7 7.5 76.0 76 181 33 101 107

75 x 21/2 16 44 30.2 4.8 88.0 95 300 33 101 108

9 x 3 16 51 33.3 15.7 110.0 110 470 33 101 109

110 x 4 16 61 39.3 10.7 131.0 131 550 33 101 110

Adaptor fittings - Sockets plain/female BSP thread with metal reinforcing ring

d x R PN L L1 Z E E1 K gms Code

16 x 3/8 16 14 11.4 5.5 23.5 23.5 24 14 33 103 101

20 x 1/2 16 16 15.0 4.0 28.5 28.5 29 23 33 103 102

25 x 3/4 16 19 16.3 5.0 35.0 35.0 35 34 33 103 103

32 x 1 16 22 19.1 6.0 43.0 43.0 43 53 33 103 104

40 x 11/4 16 26 21.4 5.0 50.0 50.0 50 62 33 103 105

50 x 11/2 16 31 21.4 8.0 61.0 61.0 61 110 33 103 106

63 x 2 16 38 25.7 7.5 76.0 76.0 76 190 33 103 107

Adaptor fittings - Reducers plain spigot/female BSP thread

dm x R PN H Lm Lf L1 E K Fig gms Code

20 x 3/8 16 36 16 14 11.4 28 24 A 11 33 169 101

25 x 1/2 16 42 19 16 15.0 34 29 A 17 33 169 102

32 x 3/4 16 49 22 19 16.3 40 35 A 26 33 169 103

40 x 1 16 57 26 22 19.1 52 44 A 49 33 169 104

50 x 11/4 16 67 31 26 21.4 59 54 A 66 33 169 105

63 x 11/2 16 77 38 31 21.4 70 64 A 129 33 169 106

90 x 21/2 16 84 51 44 30.2 - 95 B 300 33 169 107

110 x 3 16 100 61 51 33.3 - 110 B 450 33 169 108

FIG A

FIG B

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 42

email: [email protected] web: www.durapipe.co.uk 43

Met

ric

Fitt

ings

Adaptor fittings - Male threaded adaptors plain socket/male BSP thread

d x R PN Lm Lf L1 Z K gms Code

16 x 1/2 16 16 14.0 15.0 23.5 22 10 33 172 603

20 x 3/4 16 19 16.0 16.3 25.5 28 17 33 172 606

25 x 1 16 22 19.0 19.1 29.5 34 27 33 172 609

32 x 11/4 16 26 22.0 21.4 32.5 42 40 33 172 613

40 x 11/2 16 31 26.0 21.4 35.0 52 70 33 172 617

50 x 2 16 38 31.0 25.7 39.5 65 150 33 172 618

75 x 3 16 51 44.0 33.5 56.0 95 300 33 172 637

90 x 4 16 61 51.0 39.2 77.0 128 420 33 172 645

Adaptor fittings - Reducers plain spigot/female BSP thread with metal reinforcing ring

dm x R PN H Lm Lf L1 E K Fig gms Code

20 x 3/8 16 37 16 14 11.4 28 24 A 11 33 170 101

20 x 1/2 16 40 16 14 15.0 34 29 A 17 33 170 333

25 x 1/2 16 43 19 16 15.0 40 35 A 26 33 170 102

25 x 3/4 16 46 19 16 16.3 52 44 A 49 33 170 335

32 x 3/4 16 50 22 19 16.3 59 54 A 66 33 170 103

32 x 1 16 52 22 19 19.1 70 64 A 129 33 170 337

40 x 1 16 58 26 22 19.1 70 64 A 129 33 170 104

40 x 11/4 16 63 26 22 21.4 - 95 B 300 33 170 339

50 x 11/4 16 68 31 26 21.4 - 95 B 300 33 170 105

50 x 11/2 16 73 31 26 21.4 - 95 B 300 33 170 341

63 x 11/2 16 78 38 31 21.4 - 95 B 300 33 170 106

63 x 2 16 87 38 31 25.7 70 64 A 129 33 170 343

75 x 2 16 77 44 38 25.7 - 110 B 450 33 170 345

Adaptor fittings - Elbows 90° plain socket/female BSP thread

d x R PN L L1 Z Z1 E gms Code

16 x 3/8 16 14 11.4 10.0 13.0 23.5 16 33 116 101

20 x 1/2 16 16 15.0 12.0 13.0 28.5 24 33 116 102

25 x 3/4 16 19 16.3 14.0 17.0 35.0 40 33 116 103

33 x 1 16 22 19.1 18.0 20.5 43.0 72 33 116 104

40 x 11/4 16 26 21.4 22.5 27.0 54.0 125 33 116 105

50 x 11/2 16 31 21.4 27.0 37.0 61.0 175 33 116 106

63 x 2 16 38 25.7 33.0 46.0 76.0 320 33 116 107

75 x 21/2 16 44 30.2 40.5 55.0 91.0 465 33 116 108

90 x 3 16 51 33.3 48.0 65.5 108.0 795 33 116 109

110 x 4 16 61 39.3 60.0 80.0 131.0 1130 33 116 110

FIG A

FIG B

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 43

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945044

Adaptor fittings - Tees 90° plain socket/female BSP threaded branch

d x R PN L L1 Z Z1 E gms Code

16 x 3/8 16 14 11.4 9.0 11.0 23.5 20 33 146 602

20 x 1/2 16 16 15.0 12.0 13.0 28.5 32 33 146 605

25 x 3/4 16 19 16.3 15.0 17.0 35.0 52 33 146 608

32 x 1/2 16 22 15.0 17.5 18.0 41.0 92 33 146 610

32 x 1 16 22 19.1 18.0 21.0 43.0 71 33 146 612

40 x 11/4 16 26 21.4 21.5 27.0 50.0 110 33 146 616

50 x 1/2 16 31 15.0 27.0 27.5 61.0 160 33 146 618

50 x 11/2 16 31 21.4 27.0 37.0 61.0 195 33 146 622

63 x 1/2 16 38 15.0 33.5 37.5 76.0 305 33 146 624

63 x 2 16 38 25.7 33.5 46.0 76.0 405 33 146 629

75 x 21/2 16 44 30.2 41.0 54.5 91.0 605 33 146 636

90 x 3 16 51 33.3 48.5 66.0 109.0 1070 33 146 644

110 x 4 16 61 39.3 61.5 83.0 133.0 1690 33 146 652

Adaptor fittings - Elbows 90° plain socket/female BSP thread with metal reinforcing ring

d x R PN L L1 Z Z1 E E1 gms Code

16 x 3/8 16 14 11.4 10.0 13.0 23.5 24.5 16 33 178 101

20 x 1/2 16 16 15.0 12.0 13.0 28.5 29.5 24 33 178 102

25 x 3/4 16 19 16.3 14.0 17.0 35.0 36.0 40 33 178 103

32 x 1 16 22 19.1 18.0 20.5 43.0 44.0 72 33 178 104

40 x 11/4 16 26 21.4 22.5 27.0 54.0 55.0 125 33 178 105

50 x 11/2 16 31 21.4 27.0 37.0 61.0 62.0 175 33 178 106

63 x 2 16 38 25.7 33.0 46.0 76.0 77.0 320 33 178 107

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 44

email: [email protected] web: www.durapipe.co.uk 45

Met

ric

Fitt

ings

Adaptor fittings - Tees 90° equal plain sockets/female BSP threaded with metal reinforcing ring

d x R PN L L1 Z Z1 E E1 gms Code

16 x 3/8 16 14 11.4 9.0 11 23.5 24.5 24 33 123 101

20 x 1/2 16 16 15.0 12.0 13 28.5 29.0 38 33 123 605

25 x 3/4 16 19 16.3 15.0 17 35 36 60 33 123 608

32 x 1 16 22 19.1 18.0 21 43 44 105 33 123 612

40 x 11/4 16 26 21.4 21.5 27 50 51 125 33 123 616

50 x 11/2 16 31 21.4 27.0 37 61 62 210 33 123 622

63 x 2 16 38 25.7 33.5 46 76 77 415 33 123 629

Male threaded adaptors BSP male thread

Sized2 x d1 x T* PN A B D Z1 gms Code

16 x 12 x 3⁄8 16 18 331⁄2 11.4 21 4 33 151 331

20 x 16 x 3⁄8 16 22 34 11 20 6 33 151 332

20 x 16 x 1⁄2 16 22 38 15 24 10 33 151 333

25 x 20 x 1⁄2 16 28 41 15 25 12 33 151 334

25 x 20 x 3⁄4 16 30 48 16 31 19 33 151 335

32 x 25 x 1⁄2 16 34 45 15 26 15 33 151 352

32 x 25 x 3⁄4 16 36 52 16 33 30 33 151 336

32 x 25 x 1 16 36 55 19 36 32 33 151 337

40 x 32 x 3⁄4 16 42 50 15 28 28 33 151 353

40 x 32 x 1 16 42 53 19 31 34 33 151 338

40 x 32 x 11⁄4 16 46 60 21 37 50 33 151 339

50 x 40 x 1 16 52 58 19 32 50 33 151 354

50 x 40 x 11⁄4 16 52 61 21 35 60 33 151 340

50 x 40 x 11⁄2 16 52 61 21 35 70 33 151 341

63 x 50 x 11⁄4 16 65 68 21 37 95 33 151 355

63 x 50 x 11⁄2 16 65 66 21 35 105 33 151 342

63 x 50 x 2 16 65 71 26 40 150 33 151 343

63 x 75 x 11⁄2 16 75 76 21 38 125 33 151 356

75 x 63 x 2 16 75 79 26 41 145 33 151 345

90 x 75 x 2 16 95 93 26 49 275 33 151 346

90 x 75 x 21⁄2 16 95 98 30 54 280 33 151 347

75 x 90 x 3 16 95 100 34 56 300 33 151 357

110 x 90 x 3 16 110 113 34 62 390 33 151 348

90 x 110 x 4 16 128 128 39 77 420 33 151 358

125 x 110 x 4 16 128 126 39 65 500 33 151 349

*Thread size designation.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 45

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945046

Hose adaptors BSP female thread - loose nut with EPDM gasket

Size PN L H gms Code

*1⁄2 x 12 x 14 16 14.0 56 15 93 156 601*3⁄4 x 16 x 18 16 11.5 60 24 93 156 603*1 x 20 x 22 16 11.0 67 35 93 156 606

*11⁄4 x 25 x 27 16 14.0 81 55 93 156 609*11⁄2 x 30 x 32 16 16.0 97 80 93 156 613*2 x 40 x 42 16 18.0 104 140 93 156 616

*21⁄4 x 50 x 52 16 17.5 111 200 93 156 623*21⁄2 x 60 x 64 16 19.0 123 290 93 156 312*23⁄4 x 60 x 64 16 20.0 123 300 93 156 630

*Thread size designation.

Hose adaptors BSP male thread

Size PN L H gms Code

1⁄4 x 12 x 14 16 11.0 56 7 93 157 6003⁄8 x 16 x 18 16 11.4 58 14 93 157 6021⁄2 x 20 x 22 16 15.0 66 19 93 157 6053⁄4 x 25 x 27 16 16.3 81 30 93 157 608

1 x 30 x 32 16 19.1 97 45 93 157 612

11⁄4 x 40 x 42 16 21.4 104 85 93 157 616

11⁄2 x 50 x 52 16 21.4 111 120 93 157 623

2 x 60 x 64 16 25.7 123 180 93 157 630

Female threaded adaptors BSP female thread reinforced

Sized2 x d1 x T* PN A B Z1 Z2 gms Code

12 x 8 x 1⁄4 16 20 25 11 15 7 33 153 330

16 x 12 x 3⁄8 16 24 28 11 16 10 33 153 331

20 x 16 x 1⁄2 16 30 35 15 21 16 33 153 333

25 x 20 x 3⁄4 16 38 39 16 22 28 33 153 335

32 x 25 x 1 16 45 45 18 26 50 33 153 337

40 x 32 x 11⁄4 16 56 54 21 31 80 33 153 339

50 x 40 x 11⁄2 16 64 60 21 33 120 33 153 341

63 x 50 x 2 16 78 72 25 41 210 33 153 343

75 x 21⁄2 16 95 99 30 55 270 33 153 108

90 x 3 16 110 114 33 63 410 33 153 109

*Thread size designation.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 46

email: [email protected] web: www.durapipe.co.uk 47

Met

ric

Fitt

ings

Hose adaptors spigot end

Size PN L H gms Code

12 x 14 x 12 16 12 56 6 33 158 304

16 x 18 x 16 16 14 60 12 33 158 305

20 x 22 x 20 16 16 67 17 33 158 306

25 x 27 x 25 16 19 81 26 33 158 307

32 x 32 x 30 16 22 97 40 33 158 308

40 x 42 x 40 16 26 104 78 33 158 309

50 x 52 x 50 16 31 111 113 33 158 310

63 x 64 x 60 16 38 123 170 33 158 311

Saddle clamps BSP female threaded reinforced

Size (DxT) PN B C Z gms Code

50 x 1 16 75 22 38 240 33 436 208

63 x 1 16 82 22 46 400 33 436 211

75 x 1 16 88 22 53 570 33 436 214

90 x 11⁄2 16 95 31 61 970 33 436 219

110 x 11⁄2 16 105 31 70 1090 33 436 224

160 x 2 16 116 38 100 1740 33 436 237

200 x 2 16 135 38 119 2380 33 436 238

225 x 11⁄2 16 150 31 132 3660 33 436 239

225 x 2 16 150 37 132 3660 33 436 240

Tank connectors

Size PN A B D gms Code

32 x 11⁄4 16 63 66 22 90 33 235 308

Female composite unions PVC-U/Brass, BSP parallel female thread

Size PN A B Z1 Z2 gms Code

16 x 3⁄8* 16 32 37 3 7 100 33 216 305

20 x 1⁄2* 16 40 43 3 7 168 33 216 306

25 x 3⁄4* 16 48 47 3 7 290 33 216 307

32 x 1* 16 55 59 8 9 340 33 216 308

40 x 11⁄4* 16 65 68 10 8 470 33 216 309

50 x 11⁄2* 16 78 76 12 9 820 33 216 310

63 x 2* 16 88 89 12 11 970 33 216 311

*Thread sizes designation. Brass retaining nut and EPDM rubber seal.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:05 pm Page 47

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945048

Male composite unions PVC-U/Brass, BSP taper male thread

Size PN A B Z1 gms Code

16 x 3⁄8* 16 32 48 3 108 33 217 305

20 x 1⁄2* 16 40 54 3 179 33 217 306

25 x 3⁄4* 16 48 74 3 320 33 217 307

32 x 1* 16 55 86 8 420 33 217 308

40 x 11⁄4* 16 65 94 10 620 33 217 309

50 x 11⁄2* 16 78 108 12 1010 33 217 310

63 x 2* 16 88 126 12 1250 33 217 311

*Thread sizes designation. Brass retaining nut and EPDM rubber seal.

Flanges full face plain/drilled

Drilled to DIN2501 (BS4504) PN10Size PN A B D Z1 gms Code

32 16 115 27 14 4.5 150 33 319 308

40 16 140 31 15 4.5 230 33 319 309

50 16 150 36 16 4.5 280 33 319 310

63 16 163 43 18 4.5 390 33 319 311

75 16 185 49 19 5 525 33 319 312

90 16 200 58 20 7 710 33 319 313

110 16 220 69 22 8 955 33 319 314

Stub flanges serrated face

Size PN A B D Z1 gms Code

20 16 34 19.5 7 3.5 10 33 135 306

25 16 41 22 7 3 16 33 135 307

32 16 50 25 7 3 25 33 135 308

40 16 61 29 8 3 40 33 135 309

50 16 73 34 8 3 62 33 135 310

63 16 90 41 9 3 105 33 135 311

75 16 105 47 10 3 160 33 135 312

90 16 125 56 10 5 275 33 135 313

110 16 150 65 12 4 445 33 135 314

125 16 168 74 13 5 750 33 135 315

140 16 188 81 14 5 790 33 135 316

160 16 212 90.5 16 4.5 1140 33 135 317

200* 16 254 111.5 18 5.5 1840 33 135 318

225 16 273 124.5 25 5.5 1750 33 135 319

250 16 306 139.5 20 8.5 2140 33 135 320

280 16 327 161.5 32 14.5 3650 33 135 321

315 16 377 181 32 16 4950 33 135 323

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 48

email: [email protected] web: www.durapipe.co.uk 49

Met

ric

Fitt

ings

Backing rings galvanized mild steel

Drilled to DIN2501 (BS4504) PN10/PN16No. Weight

Size A B C P L Holes gms Code

20 95 6 28 65 14 4 300 13 421 306

25 105 6 34 75 14 4 400 13 421 307

32 115 6 42 85 14 4 600 13 421 308

40 140 6 51 100 18 4 850 13 421 309

50 150 6 62 110 18 4 950 13 421 310

63 165 8 78 125 18 4 1250 13 421 311

75 185 8 92 145 18 4 1480 13 421 312

90 200 8 110 160 18 8 1620 13 421 313

110 220 8 133 180 18 8 1750 13 421 314

125 250 8 150 210 18 8 2500 13 421 315

140 250 10 167 210 18 8 1940 13 421 316

160 285 10 190 240 22 8 3150 13 421 317

Drilled to ANSI Class 150No. Weight

Size A B C P L Holes gms Code

20 90 8 28 61 16 4 210 13 448 306

25 100 8 34 70 16 4 260 13 448 307

32 110 9 42 79 16 4 320 13 448 308

40 118 8 51 90 16 4 360 13 448 309

50 129 8 62 99 16 4 500 13 448 310

63 154 10 78 121 19 4 860 13 448 311

90 192 11 110 153 19 4 1270 13 448 313

110 230 11 133 190 19 8 1820 13 448 314

Drilled to DIN2501 (BS4504) PN10No. Weight

Size A B C P L Holes gms Code

200* 340 10 235 295 22 8 3450 13 421 318

225 340 12 250 295 22 8 3750 13 421 319

250 395 20 274 350 22 12 4300 13 421 320

280 395 16 303 350 22 12 6400 13 421 321

315 445 20 355 400 22 12 8200 13 421 323

Drilled to DIN2501 (BS4504) PN16No. Weight

Size A B C P L Holes gms Code

200* 340 11 235 295 22 12 3830 13 420 318

225 340 11 249 295 22 12 3190 13 420 319

250 405 20 278 355 26 12 9450 13 420 320

280 395 20 303 350 22 12 5800 13 420 321

315 460 20 355 410 26 12 8400 13 420 323

*The 200mm (NW175) stub flange supplied by Durapipe UK when usedin conjunction with backing ring; code number 421 318 and 420 318has a bolt circle diameter which matches 225mm (NW200) valves andfittings (295mm)

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 49

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945050

Flat gaskets/stub flangesEPDM

Size A B gms Code

20 34 3.5 2 13 411 306

25 41 3.5 3 13 411 307

32 50 3.0 4 13 411 308

40 60 3.0 4 13 411 309

50 72 3.3 5 13 411 310

63 90 4.0 10 13 411 311

75 106 3.0 20 13 411 312

90 125 3.1 30 13 411 313

110 150 4.0 40 13 411 314

125 166 4.0 50 13 411 315

140 180 4.0 60 13 411 316

160 205 4.0 70 13 411 317

200 253 4.0 120 13 411 318

225 274 3.8 165 13 411 319

250 306 4.0 170 13 431 320

280 330 4.0 195 13 411 321

315 379 4.2 250 13 411 322

Valve support plates galvanized mild steel

Drilled to DIN2501 (BS4504) PN10/PN16No. No.Size B C E L M N Holes gms Code

20 97 86 49 14 16 2 4 640 31 459 306

25 105 89 76 14 16 2 4 750 31 459 307

32 114 96 77 14 12 2 4 860 31 459 308

50 150 125 100 14 22 2 4 1480 31 459 310

63 160 134 100 14 24 2 4 2100 31 459 311

75 185 144 125 14 22 2 4 2500 31 459 312

90 203 150 127 14 23 2 8 2660 31 459 313

110 214 160 150 14 22 3 8 2960 31 459 314

N = No. of holes in base

For details of flange drillings see the corresponding backing ring.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 50

email: [email protected] web: www.durapipe.co.uk 51

Met

ric

Fitt

ings

VKD Double union ball valves manual - EPDM seals

VALVES

d DN PN Z L H H1 E B B1 C C1 gms Code

75 65 16 147 44 235 133 164 164 87 225 175 4380 H0 DKE 312

90 80 16 168 51 270 149 203 177 105 327 272 7200 H0 DKE 313

110 100 16 186 61 308 167 238 195 129 385 330 11141 H0 DKE 314

TK 3-way valves Plain EPDM T Port

Position 1 Position 2 Position 3 Position 4 Operation 0º 90º 180º 270°

L Diverting and isolating

T Diverting or mixing

= flow

with BS series plain female ends for solvent welding

d DN PN C C1 C2 B B1 B2 gms Code

16 10 16 83.5 29.5 54 87.5 33 50 350 HO TKE 305

20 15 16 83.5 29.5 54 87.5 33 50 350 HO TKE 306

25 20 16 98 35.5 62.5 98.5 39 56.5 600 HO TKE 307

32 25 16 105 37 68 106 45 61.5 850 HO TKE 308

40 32 16 139.5 51 88.5 135 51 76.5 1350 HO TKE 309

50 40 16 139.5 51 88.5 139 57 80.5 1750 HO TKE 310

63 50 16 154 51 103 159 69 97.5 2950 HO TKE 311

d DN PN E H H1 L Z

16 10 16 55 118 80 14 90

20 15 16 55 118 80 16 86

25 20 16 66 145 100 19 107

32 25 16 75 160 110 22 116

40 32 16 87 188.5 131 26 136.5

50 40 16 100 219 148 31 157

63 50 16 122 266.5 179 38 190.5

d DN *PN L Z H H1 E B B1 C C1 g Code

16 10 16 14 75 103 65 54 54 29 67 40 215 H0 DKE 30520 15 16 16 71 103 65 54 54 29 67 40 205 H0 DKE 30625 20 16 19 77 115 70 65 65 34.5 85 49 330 H0 DKE 30732 25 16 22 84 128 78 73 69.5 39 85 49 438 H0 DKE 30840 32 16 26 94 146 88 86 82.5 46 108 64 693 H0 DKE 30950 40 16 31 102 164 93 98 89 52 108 64 925 H0 DKE 31063 50 16 38 123 199 111 122 108 62 134 76 1577 H0 DKE 311

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 51

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945052

d DN PN L Z H E B C gms Code

16 10 16 14 54 82 53 50.0 65 150 H0 VXE 30520 15 16 16 50 82 53 50.0 65 145 H0 VXE 30625 20 16 19 53 91 62 58.0 76 220 H0 VXE 30732 25 16 22 59 103 71 65.0 85 315 H0 VXE 30840 32 16 26 68 120 84 76.0 100 505 H0 VXE 30950 40 16 31 77 139 98 85.5 112 725 H0 VXE 31063 50 16 38 98 174 117 103.0 137 1245 H0 VXE 31175 65 10 44 128 216 154 133.0 222 2600 H0 VXE 31290 80 10 51 142 244 189 154.0 270 4330 H0 VXE 313

with metric series plain female ends for solvent welding

VX Double union ball valves manual - EPDM seals

SK Single union ball valves plain EPDM seals

d DN PN L L1 Z H E E1 B C gms Code

20 15 16 16 16 60 92 55 28 49 66 145 H0 SKE 30625 20 16 19 19 71 109 66 36 58 75 240 H0 SKE 30732 25 16 22 22 74 118 75 42 66 85 325 H0 SKE 30840 32 16 26 26 81 133 87 53 76 97 505 H0 SKE 30950 40 16 31 35 86 152 100 61 86 110 680 H0 SKE 31063 50 16 38 40 105 183 122 76 100 134 1145 H0 SKE 311

with metric series plain female ends for solvent welding

SR Single union ball check valves plain ends - EPDM seals

VA Air release valves plain ends - EPDM seals

d DN PN E L Z H gms Code

20 15 16 55 16 86 102 110 H0 SRE 30625 20 16 66 19 105 124 205 H0 SRE 30732 25 16 75 22 127 149 310 H0 SRE 30840 32 16 87 26 146 172 475 H0 SRE 30950 40 16 100 31 156 187 660 H0 SRE 31063 50 16 120 38 186 224 1120 H0 SRE 311

Note - Also available with BS series plain female ends

with metric series plain female ends for solvent welding

with metric series plain male end for solvent welding

d DN PN E L L1 Z H gms Code

20 15 16 55 16 18 87 103 105 H0 VAE 306

25 20 16 66 19 20 106 125 185 H0 VAE 307

32 25 16 75 22 24 128 150 280 H0 VAE 308

40 32 16 87 26 28 145 171 415 H0 VAE 309

50 40 16 100 31 34 156 187 570 H0 VAE 310

63 50 16 122 38 41 185 223 950 H0 VAE 311

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 52

email: [email protected] web: www.durapipe.co.uk 53

Met

ric

Fitt

ings

RV Y type strainers socket union ends - EPDM seals

d DN PN A B E L Z H K Fig. gms CodeGrey Trans. max

20 15 16 16 125 72 55 16 103 135 - A 211 H0 UVE 306

25 20 16 16 145 84 66 19 120 158 - A 358 H0 UVE 307

32 25 16 16 165 95 75 22 132 176 - A 526 H0 UVE 308

40 32 16 10 190 111 87 26 155 207 - A 733 H0 UVE 309

50 40 16 10 210 120 100 31 181 243 - A 1095 H0 UVE 310

63 50 16 10 240 139 120 38 222 298 - A 1843 H0 UVE 311

HO UVE*** - Transparent PVC body

Grey or Transparentwith unionised metric series plain female ends for solvent welding

VM Diaphragm valves manual - plain spigot ends EPDM

d DN PN B B1 H h H1 I J L gms Code

20 15 10 95 26 124 12 90 25 M6 16 700 H0 VME 406

25 20 10 95 26 144 12 90 25 M6 19 700 H0 VME 407

32 25 10 95 26 154 12 90 25 M6 23 700 H0 VME 40840 32 10 126 40 174 18 115 44.5 M8 27 1500 H0 VME 40950 40 10 126 40 194 18 115 44.5 M8 32 1500 H0 VME 41063 50 10 148 40 224 18 140 44.5 M8 39 2400 H0 VME 41175 65 10 225 55 284 23 215 100 M12 44 7000 H0 VME 41290 80 10 225 55 300 23 215 100 M12 51 7000 H0 VME 413110 100 10 295 69 350 23 250 120 M12 - 10500 H0 VME 414

PR Pressure relief valves EPDM seals

d PN Z A B C D E F G gms Code

20 10 92 143 26 35 124 M6 25 12 700 H0 PRE 406

25 10 106 143 26 35 144 M6 25 12 700 H0 PRE 407

32 10 108 143 26 35 154 M6 25 12 700 H0 PRE 408

40 10 120 204 40 50 174 M8 44.5 16 1500 H0 PRE 409

50 10 130 204 40 50 194 M8 44.5 16 1500 H0 PRE 410

63 10 146 219 40 50 224 M8 44.5 16 2400 H0 PRE 411

Options: FPM Diaphragm

with metric series plain male ends for solvent welding

with metric series plain male ends for solvent welding

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 53

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945054

FK Butterfly valves manual - FPM or EPDM seals

d DN PN B2 B3 C C1 gms U Code

50 40 16 60 137 175 100 900 4 H0 FKE 106

63 50 16 70 143 175 100 1080 4 H0 FKE 107

75 65 10 80 164 272 110 1470 4 H0 FKE 108

90 80 10 93 178 272 110 1870 8 H0 FKE 109

110 100 10 107 192 272 110 2220 8 H0 FKE 110

140 125 10 120 212 330 110 3100 8 H0 FKE 111

160 150 10 134 225 330 110 3850 8 H0 FKE 112

225 200 10 161 272 420 122 6750 8 H0 FKE 113

d DN PN B2 B5 B6 G G1 G2 G3 gms U Code

250 250 10 210 317 281 88 236 76 250 18600 12 H0 FKE 114

315 300 8 245 374 338 88 236 76 250 25600 12 H0 FKE 115

250 & 315mm FK Butterfly valves come with gearbox as standard.Sizes 160mm to 225mm are available with gearbox operation on request.

lever operated

with gearbox

Actuated Valves and Flow ControlThe valves in this catalogue are only a selection of the complete range of

thermoplastic valves available.

Durapipe UK offer a comprehensive range of actuated valves with either

pneumatic or electric actuators. These are assembled at our in-house actuation

department and meet the demands of a wide range of applications found in

industrial pipework installations.

To further complement the Durapipe UK valve offering, there is a complete range

of Flow Meters, Solenoid Valves and the flow control system FLOW X3/CHEM X3.

For further information on any of these products, please do not hesitate to

contact your local Area Sales Manager or our Valves and Flow Control

Department on 01543 272424.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 54

email: [email protected] web: www.durapipe.co.uk 55

Met

ric

Fitt

ings

Cobra pipe clips

Size A B C D G Bolt/Screw gms Code

*12 – 24 25 15 16 M4/3BA/No 8 5 13 434 304

*16 – 35 25 17 16 M4/3BA/No 8 7 13 434 305

*20 – 35 30 14 16 M5/1BA/No 10 8 13 434 306

*25 – 35 35 16 17 M5/1BA/No 10 11 13 434 307

32 65 45 40 17 17 M5/1BA/No 10 14 13 434 308

40 75 65 45 20 20 M5/1BA/No 10 21 13 434 309

50 85 50 50 22 21 M6/0BA/No 10 30 13 434 310

63 102 60 60 19 21 M6/0BA/No 10 42 13 434 311

75 122 70 70 27 31 M8 94 13 434 312

90 148 80 90 39 31 M8 121 13 434 313

110 171 90 96 36 35 M8 184 13 434 314

125 185 161 96 9 17 M8 237 13 424 315

140 188 176 112 13 19 M8 252 13 424 316

160 238 219 150 10 40 M8 330 13 424 317

*Clips 32mm and above are fitted with a pipe retaining strap. Bolts/screws not supplied.

One-step solvent cement and Eco-cleaner

gms Code CodeLitres cement cleaner PVC-U cement Eco-cleaner

0.5 500 500 03 462 395 03 457 395

1.0 1100 – 03 462 396 –

Only Durapipe PVC-U solvent cement should be used for jointing ofPVC-U pipework systems.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 55

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945056

Maximum pressure/temperature relationship1. Graph is based on an ambient temperature of 20°C. 2. For higher ambient temperatures decrease the working pressure by 5% for every 10°C above 20°C ambient. 3. Durapipe PVC-U systems should not be used at temperatures in excess of +60°C or below +5°C.

Technical Information

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 56

Size Class C Class D Class E Class 73/8" - - - -1/2" - - 17.6 13.43/4" - - 22.3 18.31" - - 28.6 2411/4" - 37.2 36.2 31.811/2" - 42.7 41.5 37.32" 54.7 53.5 51.9 48.521/2" - - - -3" 81.3 78.9 76.5 -4" 104.5 101.3 98.5 -5" - - - -6" 154.1 149.3 144.9 -

Note: Dimensions are given for guidance only.

email: [email protected] web: www.durapipe.co.uk 57

Tech

nic

al I

nfo

rmat

ion

Flow calculationsPressure drop due to friction can bedetermined for practical purposes usingthe flow nomogram on the next page.

The pressure drop at a given flow ratecan be determined as follows:

1. Obtain the internal diameter of thepipe to be used by referring to thedimension table right:

2. Mark this diameter on Scale A.

3. Mark the required flow rate in litresper second on Scale B.

4. Draw a straight line connecting thepoints on Scales A and B andextend this to Scales C and D.

5. The velocity of flow in metres persecond is determined from theintersection with Scale C.

6. The frictional head loss in metresper 100 metres of pipe can then beread off Scale D.

Table of Pipe Internal Diameters

Size PN1620 16.725 20.932 26.940 33.750 42.163 53.1

FittingsThe calculation of pressure drop in fittings is more complex butcalculations can be made for equivalent lengths of straight pipeusing the Formula E = F x D where:

E = the equivalent pipe length (metres)

F = the fittings constant (see table below)

D = the fitting internal diameter in mm.

To calculate the total pressure drop in the system, the equivalentstraight pipe lengths for fittings is then added to the total straightpipe length to obtain the total drop.

Fittings constant90° Elbow 0.0345° Elbow 0.0190° Tee – straight through 0.0190° Tee – side branch 0.0690° Bend 0.0145° Bend 0.01Reducing Bush (per size reduction) 0.015Butterfly Valves 0.13Diaphragm Valves 0.23Check Valves 0.05

These values are included as a guide to facilitate calculation ofoverall system performance and should not be used in isolation.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 57

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945058

Flow nomogramA B C D

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 58

email: [email protected] web: www.durapipe.co.uk 59

Tech

nic

al I

nfo

rmat

ion

Calculating expansion and contractionTemperature variations in a pipework system will increase ordecrease the length of each pipe. This is the result of temperaturechanges in the fluid carried and also from ambient temperaturevariations.The rate of expansion or contraction of pipework is dependent onits length, its coefficient of expansion and the temperaturedifference.Increase/ decrease in pipe length is given by the formula:

Expansion = L x � x �T

where: L = length of pipe (mm)� = coefficient of linear expansion �T = temperature difference of the pipe (°C)

The coefficient of linear expansion for PVC-U = 7 x10-5/°C

Rule of thumb: PVC-U expands/contracts 0.7mm/ m per 10°Ctemperature change:

Example:What is the expansion/contraction of an insulated, 30m long, PVC-U Condenser water main, installed at 15°C,operating at a maximum temperature of 35°C and a minimumtemperature of 5°C?

Expansion:L = 30,000 mm � = 7 x 10-5

�T = 35 - 15 = 20°C

Expansion = 30,000 x 7 x 10-5 x 20°C= 42mm

Contraction:L = 30,000 mm � = 7 x 10-5

�T = 15 - 5 = 10°C

Contraction = 30,000mm x 7 x 10-5 x 10°C= 21mm

Hence the system must be designed, using expansion loops, thenatural flexibility of pipe, or expansion bellows, to cater for a totaldifferential movement of 63mm with an expansion of 42mm and acontraction of 21mm.

Catering for pipe movement

Systems installed above ground should be designed to ensure thatthere are sufficient changes in direction to accommodate expansionand contraction. The support method described later will ensurethat the pipework can move axially without snaking. If sufficient changes in direction are not available within the designof the system, alternative methods of catering for pipe movementcan be considered such as expansion loops or flexible rubberbellows.

Expansion loops

The length of unrestrained pipe (free leg length) required toaccommodate expansion can be calculated from the graph overleaf.

Pipe routingSystems installed above ground should be designed such that thereare sufficient changes in direction to accommodate expansion orcontraction. The support method described earlier will ensure thatthe pipework can move axially, without snaking. Utilise all availablepipe flexibility. Do not place clips too close to changes in direction.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 59

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945060

Example:Calculate the size of expansion loop required for a 90mm diameter pipe expanding 42mm andcontracting 21mm:Based on the worst case ie. 42mm expansion, �L = 21mm

2

Draw a horizontal line from the vertical section to meet the 90mm pipe gradient line. Drop a perpendicular from the intersection point to the horizontal scale. The figure obtained isthe free leg length of the loop required.Hence, in this instance a loop measuring 1200mm long x 600mm wide will cater for ±21mmmovement i.e. the loop will cater for both the expansion and contraction of the pipe.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 60

email: [email protected] web: www.durapipe.co.uk 61

Tech

nic

al I

nfo

rmat

ion

Support centresThe recommended distance between supports for pipes filled withwater is given in the table below. Where the contents have aspecific gravity greater than 1 the distance must be decreased bydividing the recommended centre distance by the specific gravity.For vertical pipes, support centres may be increased by 50%.

Pipe supports and clipsPipe supports and clips should provide lateral restraint and allowfree, unrestricted, axial pipe movement. Standard ‘drop rods’ maynot provide sufficient lateral restraint and the PVC-U pipe couldstart to ‘snake’. Durapipe Cobra clips are designed to meet these requirements. A suitable alternative would be mild steel saddle clips designedwith a clearance between the pipe and the clip. All steel bracketsin contact with the plastic pipe should be free of sharp edges toavoid damaging the pipe.

Size Support Supportmm/imperial Distance (m) Distance (m)

at 20°C at 50°C

16mm/3⁄8" 0.8 0.5

20mm/1⁄2" 0.9 0.6

25mm/3⁄4" 1.0 0.7

32mm/1" 1.1 0.8

40mm/11⁄4" 1.2 0.9

50mm/11⁄2" 1.3 1.0

63mm/2" 1.4 1.1

75mm/21⁄2" 1.5 1.2

90mm/3" 1.6 1.3

110mm/4" 1.9 1.3

160mm/6" 2.3 1.6

Expansion bellowsAxial expansion bellows may also be used in place of utilising thenatural flexibility of the PVC-U. These must be of a suitable designto ensure correct operation with PVC-U pipework. Contact ourTechnical Support Department for further information.

Anchor pointsThe direction of pipe movement can be controlled by the use ofanchor points at strategic positions. There are a number of methodsof securely anchoring plastic pipes, some of which are detailedbelow. However it should be noted that tight fitting pipe supportsshould not be used since damage to the pipe could occur.

Construction of typical anchor points

1. Small Bore (up to 4" Pipework)

2. Larger pipe (above 4" Pipework)

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 61

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945062

Support of heavy equipmentLarge valves, strainers and other heavy equipment should alwaysbe independently supported to prevent undue loading onto thePVC-U system. Durapipe valve support plates have been designedfor this purpose and may be used in place of flange backing rings.

Recommendations covering essential requirements for installationsbelow ground may be summarised as follows:In general, trenches should not be less than a metre deep.Trenches should be straight sided, approximately 300mm widerthan the pipe diameter to allow proper consolidation of packingmaterials.Trench bottoms should be as level as is practical.Large pieces of rock, debris and sharp objects should be removed.Alternatively gravel can be laid approximately 100mm deep on thefloor of the trench. (Sand may be used but subterranean water isliable to wash sand away and leave the pipe unsupported.)If pipes are jointed above ground, they should remain undisturbedfor 2 hours before being lowered into the trench.After laying, pipes should be covered with gravel or similar materialto a depth of 100mm above the crown of the pipe. The gravelshould be extended sideways to both trench walls and compacted.This should be done prior to testing, with joints left exposed.Care should be taken to ensure that sharp objects, stones, etc, areprevented from falling into the trench before covering the pipe.After pressure testing, joints should be covered with gravel orsimilar material, and back filling completed.A section of pipe installed below ground to the aboverecommendations is shown in the illustration.

Anchor blocksFor wholly solvent welded systems the pipework is pressurebalanced and anchor thrust blocks are not required. When rubberring joints are used it is necessary to provide concrete anchorblocks of changes in direction such as elbows, bends, tees etc.This is necessary to withstand the forces generated by systempressurisation.For greater detail, users in the U.K. are recommended to study theCode of Practice CP 312 published by the Pipe and Fittings Groupof the British Standards Institute covering installations above andbelow ground.

Buried pipes

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 62

email: [email protected] web: www.durapipe.co.uk 63

Tech

nic

al I

nfo

rmat

ion

Additional Important InformationThermal InsulationSome insulation products can contain substances capable of havinga detrimental effect on thermoplastic pipework.

Recommended insulation - A list of some of the common types ofinsulation materials known to be suitable with PVC-U pipework areas follows;

Fibre wool, such as ‘Rockwool’Armaflex Class 1 HTPhenolic foamPolystyrene

Note: the above list is not exclusive – please contact our Technical Support Department on 01543 272446 if furtherassistance is required.

Certain foam rubbers and adhesives used in conjunction with foamrubber insulation may be detrimental. We do not, therefore,recommend that insulation be bonded to the pipework. Adhesivesshould only be used to bond adjacent edges together.

Trace heatingThermoplastic pipework can be damaged by plasticisers used in theouter coverings on some heating tapes. Tapes sheathed inplasticised PVC must be avoided, unless specifically approved byus. (This comment also applies to any tapes, adhesives, or othersubstances used to secure the heating tape to the pipework.)Recommended heating tapes - The selection of heating tapes withsilicone rubber, woven wire, or woven polyester outer sheaths willeliminate the risk of plasticiser migration. These tapes are thereforepreferred for use on thermoplastic systems.

Pipe contents identificationDo not put self-adhesive labels directly on to pipe surfaces as thismay cause stress cracking. It is recommended that some sort ofbarrier, such as aluminium foil, is placed between pipe andidentification label.

Intumescent mastic and mastic sealantsCertain mastic sealants are formulated with phthalates. Phthalatesare known to be extremely aggressive toward PVC-U materials, andtherefore confirmation of the suitability of any mastic sealantshould be determined before being used in conjunction with PVC-Upipework.

Pipe clipsIt is important that the composition of pipe clips and their liningsdo not include substances which might have a detrimental effectupon the PVC-U pipe. Please check for suitability before use. We recommend the use of Durapipe Cobra clips for pipe sizes up toand including 160mm OD / 6"NB, wherever circumstances allow.

Freezing conditionsPrecautions should be taken to prevent contents freezing, as thiscan cause pipework to split.

Contact with fluxesSome fluxes can be detrimental to PVC-U. Care should be taken when soldering copper pipework directly above, or close to, PVC-U pipework.

Buried pipesDo not lay PVC-U in contaminated ground eg. ‘brown-field’ sites. Do not lay PVC-U in ground where spillages of chemicals mayoccur.

Thread sealantsSome thread sealants can damage PVC-U. PTFE tape should beused when making threaded connections. See page 69 for furtherinformation.

Resistance to U.V. (sunlight)Care should be taken to avoid exposure to U.V. light, e.g. sunlight,particularly during storage. This will cause discoloration anddeterioration of the PVC-U material. Whilst this is a surface effectonly, it is recommended that precautions be taken to prevent thishappening. If stored outdoors pipe should be covered with opaquesheeting. If installed outdoors it can be protected from the effectsof U.V. by insulating or painting.

Pressure surgesDurapipe PVC-U pipework can withstand pressure surges withinthe limitations detailed within CP312 Part 2:1973 and itsamendment dated 1977. On no account should pressure surges beallowed to exceed the maximum continuous working pressurecalculated using the graph on page 60.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 63

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945064

Durapipe PVC-U Jointing Guide

Durapipe PVC-U pipes and fittings are designed for an interferencefit. Although Durapipe PVC-U solvent cement has good gap fillingproperties no attempt should be made to increase the clearancebetween the pipes and fittings.

Solvent cement welding offers a simple and quick means ofconstructing high integrity, leak-free joints.

The solvent cement operates by chemically softening the jointsurfaces. Joint integrity will be greatly reduced if these surfaces arenot clean and properly prepared.

Durapipe PVC-U solvent cement must be used. The jointing procedure detailed below must be followed.

This relates to the new “one-step” solvent cement. With thiscement it is not necessary to abrade pipe or fitting.

Procedure1. The pipe must be cut clean and square. A suitable wheel cutter

will eliminate swarf. As an alternative (and on larger sizes) acarpenters saw should be used, however this may create dustand swarf which can enter the system.

2. Chamfer the end of the pipe using a coarse file or suitablechamfering tool. The chamfer should be approximately 45° by3mm to 5mm depending on the pipe size.

3. Mark the pipe a known distance from the end and clear of thearea to be cleaned. This mark should be used to confirm fullinsertion of pipe into socket of fitting.

4. Ensure joint surfaces are clean and free from moisture. Clean surfaces thoroughly with Durapipe Eco-cleaner using lintfree cloth/paper towel.

5. Using a clean brush, apply cement to the pipe and fitting. The joint surfaces should be completely covered by cement.

Cement should be applied using an appropriate size brush andtin of cement. It is important to apply cement quickly to enableassembly without excessive force being required.When applying cement with brush, the size of the brush shouldbe approximately half the size of the pipe to be jointed - brushsize up to 21/2" (63mm) for 0.5 litre and up to 3" (75mm) for 1 litre tins.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 64

email: [email protected] web: www.durapipe.co.uk 65

Tech

nic

al I

nfo

rmat

ion

6. Immediately after applications of cement, push pipe fully homeinto the fitting. Do not twist. Hold the pipe and the fitting fortimes varying from a few seconds on sizes 3/8” or 16mm up to1 minute on sizes 8” or 225mm and above. The slight tapermoulded into the fitting may otherwise cause it to slide off thepipe with consequent loss of joint strength. Application of thecorrect amount of cement will result in a neat bead of cementat the edge of the fitting and at the edge of the pipe. Excessivedeposits inside the fittings must be avoided as these canweaken the wall, particularly on smaller sizes. When working under cold conditions make sure the joints arefree from frost and moisture.

7. Wipe off excess cement from the outside of the joint.

8. Using the mark previously made, check that the pipe has beenfully inserted.

9. Do not disturb the joint for at least 10 minutes after assembly.Allow sufficient drying time prior to pressurisation of thesystem (see page 66).

10. Replace lids on containers.

CAUTION• DO NOT use near naked flames

• DO NOT smoke in the working area

• DO NOT use in confined spaces

• DO NOT joint in the rain or wet conditions

• DO NOT use dirty brushes

• DO NOT use dirty or oily cleaning cloths

• DO NOT use the same brushes for different cements

• DO NOT dilute or decant Durapipe PVC-U solvent cement

• Follow safety instructions on Durapipe solvent

cement and Eco-cleaner containers

• Always wear appropriate personal protective equipment

Notes1. The integrity of Durapipe PVC-U systems may be affected

if Durapipe PVC-U solvent cement is not used. Durapipe UK disclaims responsibility for any Durapipe PVC-Usystem constructed with any other cements or not fabricated inaccordance with the instructions contained herein.

2. On sizes 6" or 160mm and above use 3" wide brushes and 1 litre tins of cement.

3. To achieve the correct speed of application on sizes 4" or125mm and above, cement should be applied simultaneously topipe and fitting, by two people.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 65

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945066

Drying TimesThe drying times will vary with fit, amount of solvent cementapplied, ambient temperature and working pressure. It isrecommended that, wherever possible, joints of sizes up to8"/225mm are allowed to dry for at least 24 hours, and sizes 10"and 12"/250mm and 315mm for at least 48 hours. These guidelines are based on an ambient temperature of between10°C to 40°C. Longer drying times will be required at lowerambient temperatures.

It is recognised that there will be occasions when the system willneed to be put into service within a few hours of being made. Arough but safe working guide where the ambient temperature isbetween 10°C to 40°C and the contents temperature does notexceed 20°C is as follows:

Size Range Drying time

Up to 4"/Up to 125mm 1.0 hour/bar

5" & 6"/140mm & 160mm 1.5 hours/bar

8"/200mm & 225mm 2.0 hours/bar

10 & 12"/250mm & 315mm 30 hours minimum

Note - Minimum drying period should never be less than 1 hour

Size Joints per litremm imperial PVC-U

12 - 32 3⁄8 - 1 300

40 - 63 11⁄4 - 2 120

75 - 90 3 50

110 - 125 4 30

140 - 160 6 15

200 - 225 8 8

280 - 315 10 - 12 3

An indication of the number of joints likely to be made per litre ofDurapipe PVC-U solvent cement is as follows:

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 66

email: [email protected] web: www.durapipe.co.uk 67

Tech

nic

al I

nfo

rmat

ion

Branch connections - reduced bore

Reduced branch connections can be made as follows:

Imperial range:Bushed equal tees or Y pieces, solvent cemented saddles.

Metric range:Bushed equal tees, Y pieces or bolt-on saddles.

Solvent weld saddles permit branch connections to be made withthe main pipe in situ. The following procedure must be followedcarefully:

1. Drill hole in pipe wall to suit the connection. The size of holeand cutter to be used for each size of saddle is indicated below:

Pipe size Hole diameter Cutter size(Imperial) (mm) (Imperial)

2 48 17/8

3 61 23/8

4 74 27/8

6 74 27/8

2. Mark out the area covered by the saddle on the pipe.

3. Clean surfaces with Eco-cleaner.

4. Feed on to pipe two worm drive (Jubilee) clips which willclamp the saddle during fitting. These should be placed eitherside of the socket on the saddles. Apply cement to pipe areaand saddle. It is important to apply cement quickly.

5. Position saddle immediately, ensuring that spigot locates in hole in pipe wall. Clamp in place using worm drive clipswithout delay.

6. Wipe off any excess cement.

7. Replace lids on containers. 8. Clean brush with Eco-cleaner.

Important:1. See page 66 for details of drying times. Allow 24 hours before

removing straps.2. On no account should a branch tee be constructed by drilling

through the wall of a pipe and/or fitting and attempting tosolvent weld a smaller fitting into the hole.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 67

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945068

The use of bushes and reducers

Example in the use of reducing bushes

The use of reducersAll fittings have female ends, dimensionally controlled for coldfusion jointing. In addition the metric series reducers are providedwith controlled outside diameter at the large end. They cantherefore be used as male or female components as shown.

Reducing bushesReducing bushes offer a neat and simple method of reducingsocket size in the minimum of space.Care must be taken to prepare properly all jointing surfaces asrecommended earlier, with the end of the bush being chamfered(unless a moulded chamfer is included).

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 68

email: [email protected] web: www.durapipe.co.uk 69

Tech

nic

al I

nfo

rmat

ion

If it is required to cut a thread on to Durapipe PVC-U pipe, use asharp die especially reserved for plastic pipes and cut full threaddepth without lubricant, in one operation.This should only be attempted on pipe sizes up to 2" n.b. Class Tpipe must be used. Pipes from Durapipe PVC-U metric range arenot suitable for threading.Assembly should be carried out by hand and final tightening by astrap wrench, if necessary.Extra care must be taken not to overtighten or damage the thread.Pipe wrenches must not be used.It is recommended that PTFE tape be used when making threadedjoints/connections. Any other sealing compound must be confirmed by Durapipe UK asbeing suitable.‘Boss White’ and anaerobic adhesive sealants, such as Loctite 542and 572, can chemically attack PVC-U and must not be used.

Flange bolting procedureThe following procedure is recommended for installing DurapipePVC-U flanges:1. Inspect flange faces and ensure that they are clean and

undamaged.2. Check that the correct backing ring and rubber gaskets have

been supplied. Durapipe UK supplies a matched system offlanges and backing rings - do not interchange Metric andImperial components.

3. Loosely assemble flanges. Ensure that flanges and bolt holesalign and that the flange faces are parallel. Ensure that thegasket is correctly positioned between the flanges.

4. Ensure that the appropriate sized washer are placed under bothbolt heads and nuts.

5. Tighten the nuts and bolts in a diagonally opposite sequence(see below) to ensure even loading around the flange to avoiddistortion. It is recommended that the nuts and bolts betightened as uniformly as possible progressively from a fingertight start.

6. Repeat as necessary until recommended torque value at all boltsis achieved.

Connections for instrumentationInstrumentation connections can be made by drilling through pipeand socket where the material is at its thickest and tapping the holeto receive a threaded fitting, as shown below:Pipe size Size of connection16mm-63mm/3⁄8"-2" Use tees, reducing bushes and

threaded fittings75mm-110mm/21⁄2"-4" Max. tapping 1⁄2" BSP.125mm-140mm/5" Max. tapping 3⁄4" BSP.160mm & above/6" & above Max. tapping 1 BSP.Such connections, if correctly drilled and tapped with a full threadform, will be limited to Class C pressures.

Connections - plastics to metal There are several recommended methods to connect metal andplastic systems:Composite unionsFlangesMale threaded fittingsFemale threaded fittings

Plastics expand or contract more than metals for any given changein temperature. The practice of connecting plastic threaded fittingsto metal threads is not recommended where the joint is likely toexperience a temperature change of more than +/-5ºC, otherwiseleaks may occur.Composite unions are available with brass male or female BSP threaded adaptors.

Flanged jointsFull face flanges are available from 1⁄2" to 6" and 25mm to 110mm.Stub flanges are available from 2" to 12" and in metric sizes from20mm to 315mm.The correct galvanised mild steel backing ring and rubber gasketmust be used with both types.

Tightening torques for flangebolts in PVC-U piping systems

Size Torque16 1520 1525 1532 1540 2050 3063 3575 4090 40110 40125 50140 50160 60200 70225 70250 80315 100

The tolerance on torque is +/- 10%

Tightening sequence

Recommended Torque Values (Nm)

Threaded connections

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 69

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945070

Tabulated below is a comparison of imperial sized PVC-U pipeto BS3505 and metric sized pipe to EN 1452-2. They areproduced to different standards, but can be joined togetherusing flanges or adaptors.

The systems are also designated differently; the imperial systemrefers to the nominal bore size; the metric system relates to theoutside diameter.

Both systems are produced with the outside diameter as thecontrolled dimension. This enables the same fitting of aparticular size to be joined to all classes of pipe in that size.

Please refer to the pipe section in this brochure for pipe sizes available from Durapipe UK.

Threaded systemsImperial systems Class 7 pipe can be machined to BSP parallelor BSP taper thread forms. Metric pipe is not produced with anoutside diameter suitable for threading.

Comparison of PVC-U Imperial and Metric Sized Pipe

16 16.0

20 20.0 1.5

25 25.0 1.9

32 32.0 1.6 2.4

40 40.0 1.9 3.0

50 50.0 2.4 3.7

63 63.0 3.0 4.7

75 75.0 3.6 5.6

90 90.0 4.3 6.7

110 110.0 5.3 8.1

125 125.0 6.0 9.2

140 140.0 6.7 10.3

160 160.0 7.7 11.8

180 180.0 8.6 13.3

200 200.0 9.6 14.7

225 225.0 10.8 16.6

250 250.0 11.9 18.4

315 315.0 15.0 23.2

Size Minimum mean Minimum wall thicknessoutside diameter outside diameter (mm)

(mm) (mm) PN10 PN16

Size Minimum mean Minimum wall thickness (mm)(nominal bore) outside diameter

(inch) (mm) Class B Class C Class D Class E Class 73/8 17.0 1.5 3.2

1/2 21.2 1.7 3.7

3/4 26.6 1.9 3.9

1 33.4 2.2 4.5

11/4 42.1 2.7 4.8

11/2 48.1 2.5 3.1 5.1

2 60.2 2.5 3.1 3.9 5.5

21/2 75.2 3.0 3.9 4.8

3 88.7 2.9 3.5 4.6 5.7

4 114.1 3.4 4.5 6.0 7.3

5 140.0 3.8 5.5 7.3 9.0

6 168.0 4.5 6.6 8.8 10.8

8 218.8 5.3 7.8 10.3 12.6

10 272.6 6.6 9.7 12.8 15.7

12 323.4 7.8 11.5 15.2 18.7

Imperial System (BS 3505) Metric System (EN 1452-2)

Chemical resistance Typical Unsuitable for the Sizes and jointingand performance data applications following uses information

Properties guide

Strong mineral acids

Caustic and ammoniacal solutions

Some organics

Most detergents

Temperature range +5ºC to 60ºC

Chemicals, potablewater, general purposewater, waste water etc.

Aromatic solventstemperatures below +5°Ctemperatures over 60°C

Pipe and fittings for solventwelding manufactured in metricsizes 12mm to 315mm to DINand ISO standards and 3/8" to12" British Standards. Threadedfittings also available.

NOTE: Temperatures given are for guidance only, please check before specifying.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 70

email: [email protected] web: www.durapipe.co.uk 71

Tech

nic

al I

nfo

rmat

ion

General Information

Handling and storageThe high impact strength of Durapipe PVC-U systems providessome protection against damage but care should be taken at allstages of handling, transportation and storage.

Pipe must be transported by a suitable vehicle and properly loadedand unloaded, e.g., wherever possible moved by hand ormechanical lifting equipment. It must not be dragged across theground.

The storage should be flat, level and free from sharp stones.

LengthsPipe lengths stored individually should be stacked in a pyramid notmore than one metre high, with the bottom layer fully restrained bywedges. Where possible, the bottom layer of pipes should be laidon timber battens at one-metre centres. On site, pipes may be laidout individually in strings. (Where appropriate, protective barriersshould be placed with adequate warning signs and lamps.)

BundlesBundled packs of pipe should be stored on clear, level ground withthe battens supported from the outside by timbers or concreteblocks. For safety, bundled packs should not be stacked more thanthree metres high.Smaller pipes may be nested inside larger pipes. Side bracingshould be provided to prevent stack collapse.

Similar precautions should be taken with fittings and these shouldbe kept in protective wrappings until required for use.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 71

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945072

Health and Safety at Work Act and COSHH RegulationsAttention is drawn to the requirements in the UK of this Act and tothe Control of Substances Hazardous to Health (COSHH)Regulations. Durapipe UK cannot accept responsibility for accidentsarising from the misuse of its products because of bad installationor incorrect application.

Material safety dataMaterial Safety Data sheets are available on our website.

Filling and flushingWhen purchasing chemicals for either flushing or long-term systemuse, suppliers should be advised that this is for PVC-U material.Guidance on the suitability of various system flushing or filling fluidswith PVC-U can be found in the Durapipe Chemical Resistancebrochure, 04900004 for further details.

TestingIt is suggested that the following test procedure be followed, afterjoints have been allowed to dry for the appropriate minimum time(at least 24 hours up to 8"/225mm, sizes 10"/250mm and12"/315mm require a minimum of 48 hours at 20°C).The system should be divided conveniently into test sections.Fill section with cold water making sure that no air pockets remain. Do not pressurise at this stage.Check system for leaks. If none are apparent, check for and removeany remaining air. Increase pressure up to 3 bar. Do not pressurisefurther at this stage.Leave section pressurised for 10 minutes. If pressure decays,inspect for leaks and rectify as necessary. If pressure remainsconstant, slowly increase the hydrostatic pressure to 11/2 timesnominal operating pressure.Leave section pressurised for a period not exceeding 1 hour. During this time pressure should not change.

CautionPersonnel must stand well clear when pressure testing systems.Similarly, under no circumstances should pressure tests be carriedout using pressurised gases. Such a test could be extremelydangerous and serves no useful purpose.Note: If extended times are required to achieve hydrostatic pressure,either leakage has occurred or air remains in the line. Inspect forleakage and if none is apparent, reduce pressure and check fortrapped air. This must be removed before further pressurisationcommences.

ColourDurapipe PVC-U products are a dark-grey colour, generally inaccordance with BS5252, colour ref. 16 A 11.

Auto CAD drawingsTwo dimensional drawings of Imperial products contained in thisbrochure are available on our website www.durapipe.co.uk

Durapipe PVC-U pipe and fittingsDurapipe UK offer PVC-U pipework systems comprising pipes,fittings and valves, joined by solvent welding, together withassociated accessories. Products are available available in Imperialsizes from 3/8" to 12" (nominal bore) and Metric sizes from 16mmto 315mm (outside diameter).

PVC-U dimensions and standardsImperialThe Durapipe PVC-U Imperial System is manufactured inaccordance with the relevant British Standards as shown below.Kitemark licences are also held, where applicable, for both pipesand fittings BS 5391 (pipe) BS 5392 (fittings).

MetricThe Durapipe PVC-U Metric System is manufactured generally inaccordance with the relevant international standards as shownbelow:ISO 15493EN 1452-2

Threaded fittings conform to the requirements of BS 21/DIN2999/ISO7. Socket dimensions of Durapipe PVC-U Metric fittingsfor solvent welding comply with ISO/DIS 727-1.

MaterialsDurapipe PVC-U material is UK Water Regulations Advisory Schemeapproved for cold water services and is listed in the Water Fittingsand Materials Directory.

Gaskets and sealsGaskets and O Ring seals are made from EPDM except where statedotherwise.

CompatibilityThe components of each dimensional system are notinterchangeable with each other, except for sizes 75mm/21⁄2" and 140mm/5". They can be joined by using the mm/imperialadaptor fittings or by flanges. They are, however, interchangeablewith other piping products manufactured in accordance with thestandards referred to.

Approvals

Durapipe PVC-U Imperial series fittings are covered by KitemarkLicence No. KM05324 to BS 4346:Part 1.Durapipe PVC-U Imperial series pipes and fittings are UK WaterRegulations Advisory Scheme approved for conveying potable water,certificate number 0402050.Durapipe PVC-U materials are also UK Water Regulations AdvisoryScheme approved and are listed under 0201506 and 0201512. Durapipe PVC-U solvent cement is covered by Kitemark Licence No.KM6218 to BS 4346: Part 3, and is UK Water RegulationsAdvisory Scheme approved under 0610503.Durapipe PVC-U imperial pipe is manufactured generally inaccordance with BS 3505. Threaded fittings conform to the requirements of BS 21/DIN2999/ISO 7.Socket dimensions of fittings for solvent welding comply with ISO 727-2

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 72

email: [email protected] web: www.durapipe.co.uk 73

Tech

nic

al I

nfo

rmat

ion

AbbreviationsThe following list of abbreviations is used in this catalogue:ABS – Acrylonitrile Butadiene StyreneANSI – American National Standards InstituteBS – British StandardsBSP – British Standard Pipe ThreadDIN – Deutsche Industrie Normen

(German Industrial Standards)EPDM – Ethylene Propylene RubberFPM – Fluorine Rubber (eg. Viton®)ISO – International Standards OrganisationMEK – Methyl Ethyl KetonePN – Nominal PressurePTFE – Polytetrafluoroethylene (eg. Teflon®)PVC-C – Corzan, Chlorinated Polyvinyl ChloridePVC-U – Unplasticised Polyvinyl Chloride

® Dupont registered trade name.

Ordering by code Code numbers should be used when ordering products e.g.

Imperial

MetricRange Shape Size

PVC-U Tee 90mm

122 31333

Range Shape Size

PVC-U Tee 3"

12202 109

Code

Code

Mechanical, Physical, & Electrical Data Value

Mechanical

Ultimate tensile strength (23°C) 53 MN/m2

Tensile strength at break 45.00 MPa

Young’s Modulus 3060 MPa

Compressive strength 55 MN/m2

Poisson’s Ratio 0.35

Izod impact strength at 23°C (notched) 0.08 kJ/m2

Physical

Specific gravity 1.41

Softening point (ISO 306: 1994 method B120) 77°C

Linear coefficient of thermal expansion 7.8 (x10-5/°C)

Heat distortion point 74°C

ASTM D648 – 4.5 MN/m

Thermal Conductivity 0.147 W/m °C

Specific heat 0.84-2.1 J/g

Electrical

Dielectric constant 3.0 at 106Hz

Volume resistivity 1016

ohm/cm

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 73

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945074

Product SpecificationIMPERIAL RANGEDURAPIPE PVC-U PIPES

In accordance with the dimensional and testing requirements of BS 3505, Third Party Approved with British Standard Kitemark Licence.

DURAPIPE PVC-U FITTINGSIn accordance with the dimensional and testing requirements of BS 4346 Part 1, Third Party Approved with British Standard KitemarkLicence.

MATCHED SYSTEMThe PVC-U products are designed to ensure complete integrity, qualityand compatibility between pipes, fittings and valves. Manufacturerswarranties may be compromised if a system is installed with materialsfrom various manufacturers. Where this is not possible then anyalternative products should be confirmed as being at least equivalent tothat which is normally supplied.

QUALITY SYSTEMPipes, fittings and valves shall be manufactured in an environment,which operates a Quality Assurance System assessed to ISO 9001.

ENVIRONMENTAL SYSTEMThe manufacturer of pipes, fittings and valves shall be able todemonstrate compliance with applicable environmental legislation andproducts shall be manufactured in an environment where documentedperformance reviews are undertaken and an Environmental ManagementSystem is successfully assessed to ISO 14001.

DRINKING WATER/ APPROVAL FOR USE IN CONTACTWithin private property boundaries all PVC-U pipes, fittings and solventcement shall be listed in the Water Fittings and Materials Directory toshow compliance with the requirements of the United Kingdom WaterRegulations Advisory Service.In any situation which could result in the PVC-U pipes, fittings andsolvent cement coming into contact with water which is intended forhuman consumption these shall be in accordance with the requirementsof BS 6920 Part 1.Copies of certification of compliance with these approvals must beavailable for inspection.

THIRD PARTY APPROVALSThe manufacturer shall have the following Third Party Approvals:

BRITISH STANDARD KITEMARK LICENCEKM06218 for solvent cement to BS 4346 Part 3

WRAS WATER REGULATIONS ADVISORY SCHEME0112065 for Imperial fittings0610503 for Durapipe solvent cement (5560)

DESIGN LIFEDurapipe pipes, fittings and valves are designed to operate continuouslyfor 50 years at their maximum rated pressure at a working temperatureof 20°C.

CHEMICAL SUITABILITY The manufacturer shall publish detailed chemical resistance data toenable the suitability of the PVC-U material, seals, and gaskets to bedetermined by designers and specifiers.The manufacturer shall also employ a qualified and experienced Chemistand provide a free-of-charge advisory service for assessing the suitabilityof its PVC-U material, seals, and gaskets.

INSTALLATION SPECIFICATIONThe installation must be carried out by competent persons. The contractor shall be required to provide technical documentationrelating to the manufacturers recommended Installation procedures. The manufacturer shall publish Installation recommendations, and shallalso provide a free-of-charge training service for designers and installers,with appropriate written confirmation of attendance.

DURAPIPE PVC-U BALL VALVESTrue union design, end load resistant with full pressure and shockresistant anti blow out device which conforms to design and endurancetesting requirements of DIN 3441 Part 1, and DIN 3230 Part 3 LeakRate One (Water and Air). Drop Tight and Bubble Tight testing have been satisfactorily completed. In addition, the following testing has been successfully conducted:Hydrostatic Shell Test 1.5 x Maximum Working Pressure.Seat Test 1.1 x Maximum Working Pressure.

PRESSURE RATINGPN16 at 20°C

SEATS AND SEALSSeats: Will be PTFE material fitted with O ring compensators. Seals: Will be standard size O ring type for ease of replacement, inEPDM or FPM material.

END CONNECTIONSPlain socket ends, or BSP threaded.

ACTUATIONOptions: Electric or pneumatic.

DURAPIPE PVC-U TK-3 WAY BALL VALVESTrue union design. Options of ‘L’ or ‘T’ port configuration.The following testing will have been successfully completed:Drop Tight and Bubble Tight Test.Hydrostatic Shell Test 1.5 x maximum recommended pressure.Seat Test 1.1 x maximum working pressure.

PRESSURE RATING1/2" to 2" – PN16 at 20°C.

SEATS AND SEALSSeats: Will be PTFE material fitted with O ring compensators. Seals: Will be standard size O ring type for ease of replacement, in EPDM or FPM material.

END CONNECTIONSPlain socket ends or BSP threaded.

DURAPIPE PVC-U DIAPHRAGM VALVESWill be equipped with a maintenance free hand wheel actuator withspindle extension to indicate the position of the valve open or closed.The body retaining bolts will be fixed from the underside, to provide acrevice free outer surface to prevent accumulation of debris or risk ofcorrosion of exposed steel bolts from chemical spillage.Valves will have been hydrostatically pressure tested to the requirementsBS 4346 Part 1, BS 5156, ISO 7508 and DIN 3230 Part 3 Leak RateOne

PRESSURE RATING1/2" to 4" – PN10 at 20°C

DIAPHRAGM TYPEChoice of EPDM, FPM or PTFE will be available.

END CONNECTIONThese may be plain spigot ends or flanged.

ACTUATIONOptions – Pneumatic

DURAPIPE PVC-U BALL CHECK VALVESThese shall be single union with plain socket or BSP threaded end.

PRESSURE RATING1/2" to 2" – PN16 at 20°C.

SEALSSeals: Will be EPDM or FPM material.

DURAPIPE BUTTERFLY VALVESReinforced Polypropylene body, fully lined, with PP disc.

Full flanged design, with oval holes/inserts to suit various standardflange drillings.

Lever operated, with 10 x 10° position stops, and locking device.

PRESSURE RATING11/2" to 10" – PN10 at 20°C12" – PN8 at 20°C

PRIMARY LINERAvailable in EPDM, FPM, or NBR

ACTUATIONElectric, Pneumatic, or Gearbox (standard on sizes over 8")

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 74

email: [email protected] web: www.durapipe.co.uk 75

Tech

nic

al I

nfo

rmat

ion

Product SpecificationMETRIC RANGEDURAPIPE PVC-U PIPES

In accordance with the requirements of EN 1452-2, DIN 8061/2, andISO DIS 15493. Pressure rating PN 16.

DURAPIPE PVC-U FITTINGSIn accordance with the requirements of EN 1452-3, DIN 8063, ISO727 and ISO DIS 15493. Pressure rating PN 16 up to size 160mm,and PN 10 in larger sizes.

MATCHED SYSTEMDurapipe PVC-U products are designed to ensure complete integrity,quality and compatibility between pipes, fittings and valves. Warrantiesare compromised if a system is installed with materials from variousmanufacturers. Where this is not possible then any alternative productsshould be confirmed as being at least equivalent to that which isnormally supplied.

QUALITY SYSTEMPipes, fittings and valves shall be manufactured in an environmentwhich operates a Quality Assurance System assessed to ISO 9001.

ENVIRONMENTAL SYSTEMThe manufacturer of pipes, fittings, and valves shall be able todemonstrate compliance with applicable environmental legislation andproducts shall be manufactured in an environment where documentedperformance reviews are undertaken and an EnvironmentalManagement System is successfully assessed to ISO 14001.

APPROVAL FOR USE IN CONTACT WITH DRINKING WATERWithin private property boundaries all PVC-U pipes, fittings and solventcement shall be listed in the Water Fittings and Materials Directory toshow compliance with the requirements of the United Kingdom WaterRegulations Advisory Service.

In any situation which could result in the PVC-U pipes, fittings andsolvent cement coming into contact with water which is intended forhuman consumption these shall be in accordance with the requirementsof BS 6920 Part 1.

Copies of certification of compliance with these approvals must beavailable for inspection.

THIRD PARTY APPROVALSThe manufacturer shall have the following Third Party Approvals:

BRITISH STANDARD KITEMARK LICENCEKM06218 for solvent cement to BS 4346 Part 3

WRAS WATER REGULATIONS ADVISORY SCHEME0402050 for Metric size pipe and fittings0610503 for Durapipe solvent cement (5560)

DESIGN LIFEDurapipe pipes, fittings and valves are designed to operate continuouslyfor 50 years at their maximum rated pressure at a working temperatureof 20°C.

CHEMICAL SUITABILITYThe manufacturer shall publish detailed chemical resistance data toenable the suitability of the PVC-U material, seals, and gaskets to bedetermined by designers and specifiers.

The manufacturer shall also employ a qualified and experiencedChemist and provide a free-of-charge advisory service for assessing thesuitability of its PVC-U material, seals, and gaskets.

INSTALLATION SPECIFICATIONThe installation must be carried out by competent persons.

The contractor shall be required to provide technical documentationrelating to the manufacturers recommended Installation procedures.

The manufacturer shall publish Installation recommendations, and shallalso provide a free-of-charge training service for designers andinstallers, with appropriate written confirmation of attendance.

DURAPIPE PVC-U BALL VALVESTrue union design, end load resistant with full pressure and shockresistant anti blow out device which conforms to design and endurancetesting requirements of DIN 3441 Part 1, and DIN 3230 Part 3 LeakRate One (Water and Air). Drop Tight and Bubble Tight testing have been satisfactorily completed. In addition, the following testing has been successfully conducted:Hydrostatic Shell Test 1.5 x Maximum Working Pressure.Seat Test 1.1 x Maximum Working Pressure.

PRESSURE RATINGPN16 at 20°C

SEATS AND SEALSSeats: Will be PTFE material fitted with O ring compensators. Seals: Will be standard size O ring type for ease of replacement, in EPDM or FPM material.

END CONNECTIONSPlain socket ends, BSP threaded or flanged.

ACTUATIONOptions: Electric or Pneumatic.

DURAPIPE PVC-U TK 3-WAY BALL VALVESTrue union design. Options of ‘L’ or ‘T’ port configuration.The following testing will have been successfully completed:Drop Tight and Bubble Tight Test.Hydrostatic Shell Test 1.5 x maximum recommended pressure.Seat Test 1.1 x maximum working pressure.

PRESSURE RATING16mm to 63mm – PN16 at 20°C.

SEATS AND SEALSSeats: Will be PTFE material fitted with O ring compensators. Seals: Will be standard size O ring type in EPDM or FPM material.

END CONNECTIONSPlain socket ends or BSP threaded.

DURAPIPE PVC-U DIAPHRAGM VALVESThese are equipped with a maintenance free hand wheel actuator withspindle extension to indicate the position of the valve open or closed.The body retaining bolts are fixed from the underside to provide acrevice free outer surface to prevent accumulation of debris or risk ofcorrosion of exposed steel bolts from chemical spillage.Valves have been hydrostatically pressure tested to the requirements ofDIN 8063, ISO 5208, ISO 7508 and DIN 3230 Part 3 Leak Rate One.

PRESSURE RATING20mm to 110mm – PN10 at 20°C

DIAPHRAGM TYPEChoice of EPDM, FPM or PTFE will be available.

END CONNECTIONThese may be plain spigot ends or flanged.

ACTUATIONOptions: Pneumatic

DURAPIPE PVC-U BALL CHECK VALVESThese shall be single union with plain socket or BSP threaded end.

PRESSURE RATING20mm to 63mm – PN16 at 20°C.

SEALSSeals: Will be EPDM or FPM material.

DURAPIPE BUTTERFLY VALVESReinforced Polypropylene body, fully lined, with PP disc.Full flanged design, with oval holes/inserts to suit various standardflange drillings.Lever operated, with 10 x 10° position stops, and locking device

PRESSURE RATING50 mm to 250mm – PN 10 at 20°C315 mm – PN 8 at 20 °C

PRIMARY LINERAvailable in EPDM, FPM, or NBR

ACTUATIONElectric, Pneumatic, or Gearbox (standard on sizes over 225 mm).

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 75

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945076

Vulcathene• Safe chemical drainage • Two easy jointing methods - Mechanical or Enfusion • Ideal for schools, universities and colleges, hospitals and clinics, pharmaceutical and research organisations

Air-Line Xtra • High performance thermoplastic pipework system for compressed air

Polypropylene • Conveys chemicals at temperatures up to 100ºC• Excellent resistance to a wide range of substances• Available in larger diameters up to 500mm• Full range of valves

Corzan• Solvent weld thermoplastic pipe system for aggressive substances• Designed specifically for use in highly corrosive conditions at temperatures up to 95ºC• Valves range available

PVC-U• Versatile, multi-purpose solvent weld pipework system with an extensive range of valves and fittings.

The established system for process and industrial handling of chemicals and water up to 60ºC

Fuel Systems• Purpose designed for safe fuel transfer• Suitable for pressure and vacuum applications • Resists fuel permeation

Durapipe UK Pipework Systems

Flow Control• Manual and actuated flow control solutions • For use with all Durapipe systems • Lightweight and easy to install

ABS• Ideal for chilled, potable and waste water• Tough, durable, lightweight and fully approved• Suitable for use from -40°C to +70°C• Fully matched system of pipes, fittings and valves

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 76

email: [email protected] web: www.durapipe.co.uk 77

Notes

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 77

Tel: +44 (0)1543 279909 Fax: +44 (0)1543 27945078

Notes

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 78

email: [email protected] web: www.durapipe.co.uk 79

1. DEFINITIONS:‘Seller’ shall mean Glynwed Pipe Systems Limited, registered in England under number1698059. ‘Buyer’ shall mean any company, organisation or individual to whom a quotationis offered, or whose order is accepted by the Seller.

2. CONDITIONS:All offers, quotations, estimates, acceptances and contracts are subject to theseConditions of Business and any terms or conditions which any other person shall seek toimpose or make part of any contract shall, so far as is inconsistent with these Conditionsof Business, not apply unless expressly agreed by the Seller in writing. The headings inthese conditions are for convenience only and shall not affect their interpretation.

3. QUOTATIONS AND PRICE VARIATION:a) Any quotation given by the Seller is an invitation to the Buyer to make an offer only andno order of the Buyer placed with the Seller in pursuance of a quotation or otherwise shallbe binding on the Seller unless and until it is accepted in writing by the Seller.

b) Unless stated otherwise, all quotations and published price lists are ex works, exclusiveof VAT and shall remain valid for 30 days or such a period as may be quoted butnevertheless the Seller may amend or withdraw any quotation by written or oral notice.Quotations may be varied if the Buyer makes variations in his specifications.

4. STATEMENTS OR REPRESENTATIONS TO THE BUYER:If any statement or representation has been made to the Buyer upon which the Buyerrelies other than in the documents enclosed with the Seller's quotation, the Buyer must setout that statement or representation in a document to be attached to or endorsed on theorder in which case the Seller may submit a new quotation.

5. DELIVERY - TIME:a) Any period for delivery given at any time and in any manner by the Seller is an estimateonly and is not binding on the Seller. Delivery periods are normally calculated from thelater of:

i) acceptance of order; or

ii) where applicable, the receipt by the Seller of a detailed specification or drawings.

b) Time shall not be deemed to be of the essence of the contract. Failure by the Seller tomeet any quoted delivery period for any part or the whole of the order shall not entitle theBuyer to rescind the contract or to claim damages of any nature.

c) The Seller will endeavour to comply with reasonable requests by the Buyer forpostponement of delivery but shall be under no obligation to do so. Where delivery ispostponed otherwise than due to default by the Seller the Buyer shall pay all costs andexpenses including a reasonable charge for storage and transportation occasionedthereby and an extra charge for split delivery if applicable.

d) The Buyer will receive delivery of any consignment between the hours of 8.00am and4.00pm Monday to Friday inclusive, unless otherwise agreed in writing. Cost incurred bythe Seller arising from the Buyer's refusal to accept consignments within the agreed hoursshall be borne by the Buyer.

6. DELIVERY AND RISK:a) Except where stated to the contrary in the contract, delivery shall be made as follows:

i) where the Buyer provides the transport, delivery shall be made ex the Seller's works;

ii) where the Seller provides the transport, delivery shall be made to the premises of theBuyer, or the premises of the Buyer's customer or works site if the Buyer has requesteddelivery to be so made but where the Buyer has made such a request the Seller will make a first delivery to the Buyer's customer or works site as so much of the goods as is available for that delivery but subsequent deliveries will be made to the premises of the Buyer.

b) The Seller may at its discretion make partial delivery of orders and invoice the same.

c) Risk in the goods shall pass on delivery.

d) Where goods are sent FOB the Seller's responsibility shall cease when the goods areplaced on board ship or aircraft without the need for the Seller to give notice to the Buyerand the provisions of Section 32(3) of the Sale of Goods Act 1979 shall not apply.

7. OWNERSHIP OF GOODS:a) The goods shall remain the sole and absolute property of the Seller as legal andequitable owner until such time as the Buyer shall have paid to the Seller the contract pricetogether with the full price of any other goods the subject of any contract between theSeller and the Buyer.

b) The Buyer acknowledges that until such time as the property in the goods passes to theBuyer he is in possession of the goods as a bailee and fiduciary agent for the Seller andthe Purchaser shall store the goods in such a manner that they are clearly identifiable asthe property of the Seller.

c) Until payment due under all contracts between the Buyer and the Seller had been madein full, in the event of sale of the goods by the Buyer:

i) the Seller shall be entitled to trace all proceeds of sale received by the Buyer through any bank or other account maintained by the Buyer; and

ii) the Buyer shall if requested by the Seller in writing to so assign its rights to recover theselling price of the goods from the third parties concerned. Such monies to be held separately by the Buyer as agent on behalf of the Seller.

d) The Seller may for the purpose of recovery of its goods enter upon any premises wherethey are stored or where they are reasonably thought to be stored and may repossess thesame.

8. TERMS OF PAYMENT:In the event of default in payment according to the agreed payment terms between theSeller and the Buyer – ie: by the end of the month following the month of despatch of thegoods the Seller shall be entitled without prejudice to any other right or remedy to suspendall further deliveries and to charge interest on any amount outstanding at the rate of 2%per month until payment in full is made (a part of a month being treated as a full month forthe purpose of calculating interest).

9. SHORTAGES AND DEFECTS APPARENT ON DELIVERY:a) It shall be the responsibility of the Buyer to inspect or arrange for an inspection of thegoods on delivery whether the goods are delivered to the Buyer's premises or to thepremises of the Buyer's customer or to a works site. If no such inspection is made theBuyer shall be deemed to have accepted the goods.

b) The Buyer shall have no claim for shortages or defects apparent on inspection unless:

i) a written complaint is made to the Seller within three days of receipt of the goods specifying the shortage or defect; and

ii) the Seller is within seven days of receipt of the complaint given an opportunity to inspect the goods and investigate the complaint before any use is made of the goods.

c) If a complaint is not made to the Seller as herein provided then in respect of suchshortages or defects the goods shall be deemed to be in all respects in accordance withthe contract and the Buyer shall be bound to pay for the same accordingly.

10. CLAIMS FOR DEFECTS NOT APPARENT ON INSPECTION:a) The Buyer shall have no claim for defects not apparent on inspection unless the Selleris notified of defective workmanship or materials within twelve months from delivery of thegoods. Provided that the goods have been installed and applied in accordance with anyrelevant recommendations made by the Seller, the Seller will at its option replace thegoods or refund the net invoiced price in respect of the goods which have been shown tobe defective. If the Seller does so supply substitute goods the Buyer shall be bound toaccept such substituted goods in full satisfaction of the obligations of the Seller under thecontract.

b) The Buyer shall in any event have no claim or set-off in respect of defects unless awritten complaint is sent to the Seller as soon as the defect is noticed and no use is madeof the goods thereafter or alteration made thereto by the Buyer before the Seller is givenan opportunity to inspect the goods.

c) The Buyer is responsible for ensuring that the goods are fit for any particular purpose,and no warranty or condition of fitness for any particular purpose is to be implied into thecontract.

11. LIABILITY:Save as stated in Conditions 9 and 10 (and save in respect of death or personal injuryresulting from the negligence of the Seller its servants or agents) the Seller shall not beliable for any claim or claims for direct or indirect consequential or incidental injury loss ordamage made by the Buyer against the Seller whether in contract or in tort (includingnegligence on the part of the Seller its servants or agents) arising out of or in connectionwith any defect in the goods or their fitness or otherwise for any particular purpose or anyact omission neglect or default of the Seller its servants or agents in the performance ofthe contract.

12. FORCE MAJEURE:Notwithstanding anything herein contained neither the Buyer nor the Seller is to be heldliable for any delay or failure to carry out the contract due wholly or in part to an act of Godaction by any Government whether British or foreign civil war strikes and/or lockoutswheresoever occurring fire trade disputes floods or unfavourable weather or any materialbecoming unavailable or irreplaceable (whether at all or at commercially acceptableprices) or any other circumstances beyond the control of the Seller.

13. SUB-CONTRACTING:The Seller reserves the right to sub-contract the fulfilment of any order or any part thereof.

14. INSOLVENCY AND BREACH OF CONTRACT:In the event that:

a) the Buyer commits any breach of the contract and fails to remedy such breach (if capable of remedy) within a period of thirty days from receipt of a notice in writing fromthe Seller requesting such remedy; or

b) any distress or execution is levied upon any of the goods or property of the Buyer; or

c) the Buyer offers to make any arrangements with or for the benefit of its creditors or (if an individual) becomes subject to a petition for a bankruptcy order or (being a limitedcompany) has a receiver appointed of the whole or any part of its undertaking property orassets; or

d) an order is made or a resolution is passed or analogous proceedings are taken for thewinding up of the Buyer (save for the purpose of reconstruction or amalgamation withinsolvency and previously approved in writing by the Seller) the Seller shall thereupon beentitled without prejudice to its other rights hereunder forthwith to suspend all furtherdeliveries until the default has been made good or to determine the contract and anyunfulfilled part thereof or at the Seller's option to make partial deliveries. Notwithstandingany such termination the Buyer shall pay to the Seller at the contract rate for all the goodsdelivered up to and including the date of termination.

15. INDUSTRIAL PROPERTY RIGHTS:If goods supplied by the Seller to the Buyer's design or specifications infringe or arealleged to infringe any patent or registered design right or copyright the Buyer willindemnify the Seller against all damages, costs and expenses incurred by the Seller as aresult of the infringement or allegation. The Buyer will give the Seller all possible help inmeeting any infringement claim brought against the Seller.

16. BUYER'S ERROR IN ORDERING:In the event the Buyer orders incorrectly the Seller will be under no obligation to the Buyerto rectify or assist in rectifying the error.

17. LAW AND JURISDICTION:The contract shall be subject in all respects to English Law and to the jurisdiction of theEnglish Courts.

DURAPIPE UK CONDITIONS OF SALE

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 79

Distributor

04900033 May 2007

Registered office:

Durapipe UKWalsall Road Norton CanesCannockStaffordshireWS11 9NSUnited KingdomTel: +44 (0)1543 279909Fax: +44 (0)1543 279450email: [email protected]: www.durapipe.co.uk

Durapipe UK reserves the right to modify the details in this publication as products and specifications are updated and improved.The content of this publication is for general information only and it is the user’s responsibility to determine the suitability of any product for the purpose intended.

For further information on all Durapipe UK products and services contact our Customer Services Team as detailed below.

Durapipe UK is a trade name of Glynwed Pipe Systems Ltd. Company Number 1698059.

19526 d_PVCUtech LOWRES.qxd 11/5/07 5:06 pm Page 80


Recommended