+ All Categories
Home > Documents > pipeshields_022015

pipeshields_022015

Date post: 17-Aug-2015
Category:
Upload: carlosanez
View: 16 times
Download: 0 times
Share this document with a friend
Description:
pipeshields_022015
Popular Tags:
132
Transcript

PipeShieldsInc.1.5.3.2.1. Cold insulated pipe anchors with axial stops.2. Custom cryogenic pipe supports fabricated for an LNG facility.3. 274 custom hot pipe shoes rush project which were delivered in three weeks.4. Insulated pipe supports designed for cryogenic temperatures down to -320F in an LNG facility. 5. Custom high temperature pipe supports for a granular activatedcarbon manufacturing plant.4.PipeShieldsInc.1PipeShields, Inc.TABLE OF CONTENTSGeneral Introduction....................................................................................................................................................Temperature, Dimensional and Material Variances.................................................................................................Use of the Insulated Pipe Support Selection Guide..............................................................................................Table1:WaterService-PipeSupportedfromAboveorBelow.............................................................Table2:Steam/Gas/AirService-PipeSupportedfromAboveorBelow..............................................Table3:WaterService-PipeSupportedfromAboveinClevisor2-BoltHanger...............................Table4:Steam/Gas/AirService-PipeSupportedfromAboveinClevisor2-BoltHanger..................Table5:WaterService-PipeSupportedfromBelowonPipeRollorAbove.....................................Table6:Steam/Gas/AirService-PipeSupportedfromBelowonPipeRollorAbove......................Section A: Pre-Insulated Pipe Support - Commerical & Light IndustrialIntroduction/Index ..................................................................................................................................................Insulated Pipe Support.....................................................................................................................ModelA1000: Regular Duty...................................................................................................ModelA2000: Regular Duty w/ Extended Insulation...............................................................ModelA3000: Extra Heavy Bottom Jacket..............................................................................ModelA4000: Extra Heavy Bottom Jacket with exterior Insulation...........................................ModelA5000: With Load Distribution Plate.............................................................................ModelA6000: With Load Distribution Plate with exterior Insulation..........................................ModelA7000: Heavy Duty with Load Bearing Plate.................................................................ModelA7200: Heavy Duty with Load Bearing Plate.................................................................ModelA7400: Heavy Duty with Load Bearing Plate.................................................................ModelA8000: Heavy Duty with Load Bearing Plate.................................................................ModelA8200: Heavy Duty with Load Bearing Plate.................................................................ModelA8400: Heavy Duty with Load Bearing Plate.................................................................ModelA9000: Heavy Duty for use with Rod Hangers...............................................................Section B: Pre-Insulated Pipe Support - Heavy Industrial - Base MountedIntroduction/Index....................................................................................................................................................Sliding Insulated Pipe Support-Heavy Duty, Base Mounted........................................................ModelB1000: .......................................................................................................................Model B1100: ........................................................................................................................ModelB1200: .......................................................................................................................Model B1300: ........................................................................................................................Model B2000: ........................................................................................................................Model B2100: ........................................................................................................................Model B2200: ........................................................................................................................ModelB2300: .......................................................................................................................Guided Insulated Pipe Support-Heavy Duty, Base Mounted.......................................................ModelB3000: ......................................................................................................................ModelB3100: ........................................................................................................................ModelB3200: ........................................................................................................................ModelB3300: ........................................................................................................................ModelB4000: ........................................................................................................................ModelB4100: ........................................................................................................................56-1213-1813141516171819-3420-2122-342223242526272829303132333435-4736-3940-47404142434445464748-554849505152532PipeShieldsInc.ModelB4200: .......................................................................................................................ModelB4300: .......................................................................................................................WideBase Sliding Insulated Pipe-Support-Heavy Duty, Base Mounted.......................................ModelB5000: .......................................................................................................................ModelB5100: .......................................................................................................................ModelB5200: .......................................................................................................................ModelB5300: .......................................................................................................................ModelB6000: .......................................................................................................................ModelB6100: .......................................................................................................................ModelB6200: .......................................................................................................................ModelB6300: .......................................................................................................................LaterallyRestrainedInsulatedPipeSupport-HeavyDuty,BaseMounted............................ModelB7000: .......................................................................................................................ModelB7100: .......................................................................................................................ModelB7200: .......................................................................................................................ModelB7300: .......................................................................................................................ModelB8000: .......................................................................................................................ModelB8100: .......................................................................................................................ModelB8200: .......................................................................................................................ModelB8300: .......................................................................................................................Section C: Insulated Pipe Support - Heavy Industrial - AnchorsIntroduction/Index............................ ........................................................................................................................WeldedTee Pipe Anchor Small Bore..............................................................................................Model C1000, Model C1010, Model C1020, Model C1030.....................................................Model C1100, Model C1110 , Model C1120, Model C1130.....................................................Model C2000, Model C2010, Model C2020, Model C2030.....................................................ModelC2100, Model C2110, Model C2120, Model C2130....................................................Insulated Friction Pipe Anchor .................................................................................................Model C3000: .......................................................................................................................Model C3100: .......................................................................................................................Model C3200: .......................................................................................................................Model C3300: .......................................................................................................................Insulated Positive Anchor..............................................................................................................ModelC4000, Model C4010, Model C4020, Model C4030 ..................................................ModelC4100, Model C4110, Model C4120, Model C4130...................................................ModelC4200, Model C4210, Model C4220, Model C4230 ..................................................ModelC4300, Model C4310, Model C4320, Model C4330................................................... Section D: Insulated Pipe Support - Heavy Industrial - HungIntroduction/Index....................................................................................................................................................Insulated 2-Bolt Hanger.....................................................................................................................Model D1000......................................................................................................................ModelD2000:......................................................................................................................ModelD3000:.....................................................................................................................ModelD3100:.......................................................................................................................ModelD3200:.....................................................................................................................ModelD3300:.......................................................................................................................Insulated 2-Rod Hanger.....................................................................................................................ModelD4000:....................................................................................................................545556-63565758596061626364-71646566676869707172-8572-7374-777475767778-817879808182-858283848586-9986-8788-9388899091929394-99943PipeShieldsInc.ModelD5000: ....................................................................................................................................ModelD6000: ....................................................................................................................................ModelD6100: ....................................................................................................................................ModelD6200: ....................................................................................................................................ModelD6300: ....................................................................................................................................Section E: Insulated Pipe Support - Pipe Riser ClampIntroduction/Index....................................................................................................................................................Insulated Pipe Riser Clamps for Downlward Loads......................................................................Model E1000, Model E1010, Model E1020, Model E1030....................................................Model E1100, Model E1110, Model E1120, Model E1130....................................................Model E1200, Model E1210, Model E1220, Model E1230....................................................Model E1300, Model E1310, Model E1320, Model E1330....................................................Insulated Pipe Riser Clamps for Upward or Downward Loads....................................................Model E2000, Model E2010, Model E2020, Model E2030. ..................................................Model E2100,Model E2110, Model E2120, Model E2130.....................................................Model E2200, Model E2210, Model E2220, Model E2230....................................................Model E2300, Model E2310, Model E2320, Model E2330 ...................................................Section G: Pipe Clamps, Pipe Guide Straps, Pipe Guide U-BoltsIntroduction/Index.............................................................................................................................................ModelG1000: Pipe Shield Clamp.......................................................................................................ModelG1200: Pipe Clamp Tubing Clamp - Neoprene Sleeved...............................................................ModelG2000: Pipe Clamp Shield Guide Strap......................................................................................ModelG2200: Pipe Clamp Tubing Clamp - Neoprene Sleeved...............................................................ModelG3000: Pipe Guide U-Bolt Shield Guide U-Bolt............................................................................Completed Projects...................................................................................................................................................Frequently Asked Questions........................................................................................................................................9596979899100-109100-101102-105102103104105106-109106107108109110-128110-106112113114115116119-125127-1284PipeShieldsInc.1. Pre-insulated pipe shoes made with carbon steel.2. High temperature support with an outside diameter of 58 and are capable of handling temperatures up to 1500F. They are fabricated from a combination of carbon steel for the top and stainless steel for the bottom. 3. 60 hot shoes for a chemical plant in Texas. These shoes are used in processes where it is imperative that thermal energy is not lost through the pipe support. 4. Hot shoes fabricated from steel carbon with a red oxide and calcium sillicate insulation.1. 2.3.4.5PipeShieldsInc.Pipe Shields, Inc. pioneered the frst insulated pipe support in 1971 for use on HVAC and plumbing lines. These supports were designed because fberglass pipe insulation is not strong enough to carry the load at the point of support without crushing. The various methods contractors employed to compensate for this weakness were inconsistent, non-uniform and labor intensive, often resulting in damage to the vapor barrier and/or pipe insulation. The insulated pipe support flled the need for an energy effcient, economical and practical support.Pipe Shields, Inc. has developed a large and growing family of insulated pipe supports, using its standard concept of incorporating materials strong enough to carry the load while insulating the pipe at the same time. No welding to the pipe is required (except for insulated positive anchors and insulated pipe riser clamps) and no direct metal-to-metal heat path exists. Insulated pipe supports meet an assortment of requirements, including: Pipe supported on:oFlat SurfaceoPipe RolloClevis Hanger Gas Steam Super Heated Steam Chilled Water Styrene Guide Supports Sliding Supports Restrained Supports Anchors Pipe Hangers Pipe Riser Clamps Thermal Growth Small or Large Maximum Support Spacing Light, Medium or Heavy Loads Ultra-High Temperatures Minimum Overhead Clearance Minimum Horizontal Clearance Minimum Field Labor Minimum Friction Loads Easy InstallationOther products designed, manufactured and supplied not included in this catalog are:1.Seismic pipe restraints2.Heat-traced pre-insulated pipe supports3.Pipe supports used in computer chip, styrene plants and oil refneries4.Pipe supports for solar energy projects to accommodate expansion travels in excess of 5- 0Ourhighlysophisticatedproductsareadirectresultofyearsofresearch,engineeringand design to develop cost effcient products for the power, petrochemical, chemical and commercial markets.Weworkcloselywithengineeringfrmsandin-houseengineeringdepartmentsof owners to provide working solutions to meet their engineering challenges. We have established proprietary specifcations that have now become an industry standard used by owners, engineers and contractors throughout the world markets.Ifyouhaveapipesupportneednotmetbyanyoftheitemsdescribedinthiscatalog,please contact us at707-447-5014 or 1-800-538-7007.GENERAL INTRODUCTION6PipeShieldsInc.Temperature RangesPipe Shields, Inc. strongly recommends the foll owing temperature ranges for our standard insulation material:MaterialTemperature Calcium Silicate +40oF to + 1200oFNote: Can be increased to 1800F using higher density Calcium SilicatePolyurethane-275oF to +275oFPermali/Insulam-328oF to +248oFFoamglas -450oF to +900oFMaterial VariancesOur standard paint fnish is SP150 red oxide primer which meets full EPA and California safety regulations. Other paint fnishes are available upon request which include:Hot dipped galvanizedInorganic zinc (CZ11HS)Dupont (Corlar) 25P epoxySP145 grey oxideCarbothane134HGCarbozinc 859Slide plate material and other feld welded material are coated with deoxaluminate (silver coating).Model Designation for Alternate Insulation MaterialsPolyurethane Add U after Catalog Model NumberExample: B1000UUrethane/Foamglas Add UF after Catalog Model Number Example: B1000UFCalcium Silicate/Foamglas Add CF after Catalog Model Number Example: B1000CFTEMPERATURE, DIMENSIONAL AND MATERIAL VARIANCESwww.pipeshields.com/materials7PipeShieldsInc.MATERIALSCalcium SilicateCalcium Silicate often serves as the insulation for pipe supports in high temperature applications. Calcium Silicate is also known as Thermo-12/Gold. It is an insulating material composed of hydrous calcium silicate which, because of its light weight, low thermal conductivity and exceptional structural strength is ideal for the insulation of high temperature piping and equipment. Sometimes it is also used as block insulation. The pipe insulation comes in a complete selection of sizes. Block styles are available for application to various fat and curved surface areas.Some of Calcium Silicates major advantages and applications are given below:Major Advantages:Temperature Range to 1200FExceptional StrengthLow Thermal ConductivityEasy Application: available sizes and shapes reduce the number of required joints and make Calcium Silicate easy to work with.Energy Savings: low thermal conductivity provides signifcant energy savings.Adaptable: Calcium Silicate can also be used on a various shapes and sizes of surfaces.Fire ResistantLow Chloride Content: low corrosivityAsbestos-Free Major Applications:Hot Line Pipe Supports in Power Generation and Process Industries.Indoor and Outdoor Piping and Equipment.Block Insulation - insulation of various fat and curved surface areas.PolyurethanePolyurethane is different from most plastic materials in that it can be tailored to meet various load requirements of varying applications. Polyurethane foams are produced by reacting an equal ratio of di- or polyisocyanurates with polyols, in the presence of water, which acts as the blowing agent. Polyisocyanurates are formed when a higher ratio of di- or polyisocyanate are mixed with the polyol. All rigid foams made from polyisocyanrate systems have some form of polyurethane in them and can be called polyurethane foam. The physical properties differ very little at high densities. Polyisocyanurate foams are used in applications where dimensional stability over 200oF is required. However, for cryogenic applications, where your pipeline insulation is not exposed to high temperatures, PUF is an acceptable substitution.A common method used to obtain a change in load capacity is a change in density.At Pipe Shields, we offer 10 lbs. / ft3, 14 lbs. / ft3, and 20 lbs. / ft3 densities.Density varies when the amount of blowing agent (water content) changes.The density of polyurethane decreases with increase in water content (See Fig. 1).This relationship can be shown as follows:W = 3.706 / D1.126Where: W = % of water content D = Density of foam (lbs./ft3.)8PipeShieldsInc.In addition to density, the strength of a rigid urethane foam is also infuenced by many factors such as catalyst, surfactant, type of mixing, the type of foaming system: base polyol and isosyanate, and the infuence of each of these on the foam cell structure.Rigid urethane foams generally have an elastic region in which stress is nearly proportional to strain. They do not exactly follow Hookes Law (stress is proportional to strain) because the curve is very slightly S shaped. Fig. 2 shows this in detail.Polyurethane is anisotropic, or polyurethane is stronger in the direction of foam rise. At Piping Technology and Products, the anisotropic character or directional properties of our polyurethane is reduced by overloading the mold used to form the polyurethane. By overloading the mold, we can control the cell structure and provide uniform physical properties.A relationship between compressive strength and the density of the foam is given in Fig. 3.Polyurethane is a thermosetting material; however, it does soften slightly with increased temperature and hardens somewhat at very low temperatures. Softening at high temperatures affects the polyurethane in two ways: (a) loss of strength properties and (b) change in foam dimensions (particularly low-density foams). Low temperatures generally have very little effect on polyurethane properties other than to make them a little harder and more brittle. See Fig. 4 for these effects.Rigid polyurethane foams have a relatively large amount of cross-linking as the foam expands. Our suppliers of the raw chemicals control the degree of cross-linking by functionality (higher functionality produces more cross-links) and molecular weight of the components in the blend. The rigid cells provide the poured foam with strength and the interior space provides low thermal conductivity.Water is used as the blowing agent for foam in this 10 to 40 lb. density range.The relationship between temperature, thermal conductivity and the density of polyurethane foam is shown in Fig. 5.The relationships of foams density with its Elastic Modulus in Compression, Tensile Strength, Elastic Modulus in Tension, and Shear Strength are given in Figs. 6 through 9 respectively. Please see the following for the respective curves.Pipe Shields has a complete manufacturing facility for production of polyurethane required for pipe supports. We invite our customers to visit our facility and observe the fabrication of insulated pipe supports of all types.9PipeShieldsInc.FoamglasFoamglas insulation is a lightweight, rigid insulation composed of millions of completely sealed glass cells. Each cell serves as an insulating agent. Foamglas is widely used in the cryogenic and hot line pipe supports and is fabricated in various ranges of shapes, thicknesses and sizes to meet the particular requirements of an application.One unique advantage that Foamglas has is its very low moisture absorption. Since, Foamglas insulation is full of closed glass cells, it resists moisture in both liquid and vapor form. This guarantees the long term performance of the insulation. Foamglas insulations resistance to moisture ensures that, properly installed, it retains its original thermal effciency.The major advantages and applications of Foamglas insulation are listed below. For details about the physical and mechanical properties of the Foamglas material, please refer to the table.Major Advantages:Constant Insulating EffciencyFire ProtectionCorrosion ResistanceLong Term Dimensional StabilityPhysical StrengthMajor Applications:Cryogenic and Hot Line Pipe SupportsCryogenic Tanks and VesselsChilled and Hot Water Service LinesOverft and Revitalize the Old InsulationComposite Insulation Systems for Special ConditionsDENSITY COMPRESSIVE STRENGTH(psi)FLEXURAL STRENGTH (fatwise with grain) (psi)TENSILE TRENGTH (with grain) (psi)MODULUS OF ELASTICITY (psi)CLOSED CELL CONTENT (%)TEMPERA-TURE (F) CONTINUOUS OPERATIONK-FAC-TORTHERMAL CONDUCTIV-ITY (btu/hr m^2 F)SHEAR (fatwise 1/8" thk. Psi)DENSITY (lb/in^3)WATER ABSORP-TION (%)PUF (10pcf)200 400 300 6,000.00 95 -300 0.08 0.16 180 0.1157 0.22PUF (14pcf)300 600 500 11,000.00 95 -300 0.12 0.2 200 0.1736 0.18PUF (20pcf)500 1,100.00 600 20,000.00 95 -300 0.14 0.25 400 0.2893 0.1310PipeShieldsInc.Density Foamglas (8 pcf)Compressive Strength (psi) 100.00Flexural Strength (fat wise with grain) (psi) 80.00Tensile Strength (with grain)(psi) N/AModulus of Elasticity (psi) 1.4 10^5Closed Cell Content (%) N/ATemperature (F)-Continuous Operation 500 max.K-Factor N/AThermal Conductivity (btu-in/HR-ft^2-F) 0.32Shear (fat wise) (1/8" thk.) (psi) N/ADensity (lb/in^3) 0.0046Water Absorption (%) 0.2%Permali or Insulam or Laminated BeechwoodPermali or Insulam or Laminated Beechwood is an insulating material used in applications which require high tensile and compressive strength (see table below). In addition, due to its exceptional resistance to moisture, it serves as a suitable insulator where the support (fare lines & dummy legs) is exposed to harsh environment elements. Permali or Insulam is a phenolic laminated (densifed, impregnated wood) product made from carefully selected thin beechwood veneers. These wood layers are impregnated under vacuum conditions with a special synthetic resin and then densifed through the application of heat and pressure. The result is a homogenous material that combines the great strength and toughness of wood fbers with the excellent stability and dielectric properties of the most advanced thermosetting. The phenolic laminated block material is furnished with cross-directional fbers as shown in the fgure.NOTE: Cross laminated.For components in compression or for parts stressed in more than one direction.Sizes to suit most applications.Density Permali (82 pcf)Compressive Strength (psi) 30,000.00Flectual Strength (fatwise with grain) (psi) 15,000.00Tensile Strength (with grain)(psi) 15,000.00Modulus of Elasticity (psi)2.0 x 10^6Closed Cell Content (%) N/ATemperature(F)-Continuous Operation 221.00K-Factor N/AThermal Conductivity (btu/hr m^2 F) 0.0018Shear (fatwise) (1/8 thick) (psi) 7200.00Density (lb/in^3) 0.0469Water Absorption (%) 0.7511PipeShieldsInc.Foamglas Technical InformationFoamglas insulation is a lightweight, rigid insulation composed of millions of completely sealed glass cells. Each cell serves as an insulating agent. Foamglas is widely used in the cryogenic and hot line pipe supports and is fabricated in various ranges of shapes, thicknesses and sizes to meet the particu-lar requirements of an application.One unique advantage that Foamglas has is its very low moisture absorption. Since, Foamglas in-sulation is full of closed glass cells, it resists moisture in both liquid and vapor form. This guarantees the long term performance of the insulation. Foamglas insulations resistance to moisture ensures that, properly installed, it retains its original thermal effciency.The major advantages and applications of Foamglas insulation are listed below. For details about the physical and mechanical properties of the Foamglas material, please refer to the table.Major Advantages: Constant Insulating Effciency Fire Protection Corrosion Resistance Long Term Dimensional Stability Physical StrengthMajor Applications: Cryogenic and Hot Line Pipe Supports Cryogenic Tanks and Vessels Chilled and Hot Water Service Lines Overft and Revitalize the Old Insulation Composite Insulation Systems for Special ConditionsFoamglas Technical InformationFoamglas insulation is a lightweight, rigid insulation composed of millions of completely sealed glass cells. Each cell serves as an insulating agent. Foamglas is widely used in the cryogenic and hot line pipe supports and is fabricated in various ranges of shapes, thicknesses and sizes to meet the particular requirements of an application.Density Foam Glass(8 pcf)Compressive Strength (psi) 400.00Flexural Strength (fat wise with grain) (psi) 80.00Tensile Strength (with grain)(psi) N/AModulus of Elasticity (psi) 1.3 10^6Closed Cell Content (%) N/ATemperature (F)-Continuous Operation 500 max.K-Factor N/AThermal Conductivity(btu/hr m^2 F)0.7000Shear (fat wise) (1/8 thk.) (psi) N/ADensity (lb/in^3) 0.0046Water Absorption (%) 0.07012PipeShieldsInc.The tables on the following pages will assist you in making a selection of the proper and most economic insulated pipe support for your application.These Selection Guide Tables are organized by:1. SERVICEA. WaterB. Steam, Gas, or Air 2. APPLICATIONA. Pipe supported from belowa. On fat surfaceb. On pipe rollB. Pipe supported from abovea. In clevis or 2-bolt hangerThe product data sheets describing each model refer to other models in the catalog with features such as load rating, axial or lateral travel, or restraint, etc. which you may have an interest.If you have a pipe support need not met by any of the items described in this catalog, please contact us at707-447-5014 or 1-800-538-7007.Insulated Pipe Support Selection GuideUSE OF THE INSULATED PIPE SUPPORT SELECTION GUIDEwww.pipeshields.com/selectionguideService Confguration Spacing GuideWater Support from Above Clevis or 2-bolt clamp View Selection Table 3Support from Below On Flat Surface View SelectionTable 1On Pipe Roll View Selection Table 5Steam, Gas, or Air Support from Above Clevis or 2-Bolt Clamp View Selection Table 4Support from Below On Flat Surface View Selection Table 2On Pipe Roll View Selection Table 613PipeShieldsInc.Note: The maximum hanger spacing shown in Table 1 are derived from load ratings (see Product Data Sheets) of Pipe Shields, Inc. models, assuming weight of standard pipe, water, and 2 insulation. The customer should be guided by the hanger spacings allowed by the applicable code or the project engineers specifcations before making a selection. Refer to the appropriate Product Data Sheets for additional information such as load rating, compensation for temperature, axial or lateral travel, or restraint, etc.Example: Given: Pipe Diameter: 8 standard weightService: WaterSupport Spacing: 20 - 0Determine: Insulated pipe support model numberMethod: In table 1, for 8 pipe size, fnd the model(s) rated for handling 20- 0 or greater support spacing. In this case, Model A7200 is selected since it is capable of handling 21-0 support spacing. The Index Sheets to Sections A & B indicate some of the differences between models. Check Product Data Sheet for description before making a fnal selection. In this example, if the support is required to handle +/-4 1/2 of axial travel, Model B2000 would be selected (Section B Index & Product Data Sheet B2000).SERVICE: WATERAPPLICATION: PIPE SUPPORTED FROM ABOVE OR BELOWInsulated Pipe Support Selection GuideTABLE 1www.pipeshields.com/table1Pipe Size (inches)Forreference: ASME B31.1Pipe Shields Model:Commercial LightIndustrialw/ Load Distribution PlateHeavyIndustrialon Slide PadRated for CombinedLateral and Vertical LoadsA1000 A2000A3000 A4000A5000 A6000 A7000 A7200 A7400B1000 B2000 B3000 B4000 B5000B6000B1100 B2100 B3100 B4100 B5100B6100B1200 B2200 B3200 B4200 B5200B6200B1300 B2300 B3300 B4300 B5300B6300B7000 B8000B7100 B8100B7200 B8200B7300 B8300maximum hanger support spacing (feet)1/23/4771112121311 1/222 1/27910111315151214161714 16 2133 1/2451213141612121312131314141716171620191917353535354545454555555555323335334545454555555555681012171922231076128613117814121014262118202531342924204545454055555555 65302621174545423655555554 6414161820252728308 1312109222119173128262320191715403734315555524665656562181615143534302753504641656561552460634232333536141018121211982421181636322824484337321098721191614322924214339332814PipeShieldsInc.Note: The maximum hanger spacing shown in Table 2 are derived from load ratings (see Product Data Sheets) of Pipe Shields, Inc. models, assuming weight of standard pipe, and 2 insulation. The customer should be guided by the hanger spacings allowed by the applicable code or the project engineers specifcations before making a selection. Refer to the appropriate Product Data Sheets for additional information such as load rating, compensation for temperature, axial or lateral travel, or restraint, etc. Example: Given: Pipe Diameter: 8 standard weightService: SteamSupport Spacing: 30 - 0Determine: Insulated pipe support model numberMethod: In table 2, for 8 pipe size, fnd the model(s) rated for handling 30- 0 or greater support spacing. In this case, Model A7200 is selected since it is capable of handling 35-0 support spacing. The Index Sheets to Sections A & B indicate some of the differences between models. Check Product Data Sheet for description before making a fnal selection. In this example, if the support is required to handle +/-4 1/2 of axial travel, Model B2000 would be selected (Section B Index & Product Data Sheet B2000).SERVICE: STEAM, GAS OR AIRAPPLICATION: PIPE SUPPORTED FROM ABOVE OR BELOWInsulated Pipe Support Selection GuideTABLE 2www.pipeshields.com/table2Pipe Size (inches)Forreference: ASME B31.1Pipe Shields Model:Commercial LightIndustrialw/ Load Distribution PlateHeavyIndustrialon Slide PadRated for CombinedLateral and Vertical LoadsA1000 A2000A3000 A4000A5000 A6000 A7000 A7200 A7400B1000 B2000 B3000 B4000 B5000B6000B1100 B2100 B3100 B4100 B5100B6100B1200 B2200 B3200 B4200 B5200B6200B1300 B2300 B3300 B4300 B5300B6300B7000 B8000B7100 B8100B7200 B8200B7300 B8300maximum hanger support spacing (feet)1/23/4891112121311 1/222 1/291213141417181515192016 20 2533 1/245151617191516171717181920212123222625262540404040505050506060606040404040505050506060606068101221242630161210918141092017131522191726403531374045404040365050505060606060 70404036325050505060606060 7014161820323537398898151414142524242240404040454545453839383650505050606060607070707034253432505050506060606070707070246063424244485011109 20181512363227234539323333315050505060606060707070702830292850505050606060607070707015PipeShieldsInc.Note: The maximum hanger spacing shown in Table 3 are derived from load ratings (see Product Data Sheets) of Pipe Shields, Inc. models, assuming weight of standard pipe, water, and 2 insulation. The customer should be guided by the hanger spacings allowed by the applicable code or the project engineers specifcations before making a selection. Refer to the appropriate Product Data Sheets for additional information such as load rating, compensation for temperature, axial or lateral travel, or restraint, etc.Example: Given: Pipe Diameter: 8 standard weightService: WaterSupport Spacing: 20 - 0Determine: Insulated pipe support model numberMethod: In table 3, for 8 pipe size, fnd the model(s) rated for handling 20- 0 or greater support spacing. In this case, Model D3000 is selected since it is capable of handling 22-0 support spacing. The Index Sheets to Sections A & D indicate some of the differences between models. Check Product Data Sheet for description before making a fnal selection. In this example, if the clearance is above the support limited, Model D6000 might be selected (Section D Index & Product Data Sheet D6000).SERVICE: WATERAPPLICATION: PIPE SUPPORTED FROM ABOVE IN CLEVIS OR 2-BOLT HANGERInsulated Pipe Support Selection GuideTABLE 3www.pipeshields.com/table3Pipe Size (inches)Forreference: ASME B31.1Pipe Shields Model:Clevis Hanger 2-Bolt HangerA1000 A2000A3000 A4000 A9000D1000 D2000 D4000 D5000D3000 D6000D3100 D6100D3200 D6200D3300 D6300maximum hanger support spacing (feet)1/23/47711121213131511 1/222 1/27910111416171615181818171921211922292433 1/2451213141617161615181718162019191925222221 4068101217192223141312111513131216151413212224224032282614161820252728301110991211109131211102021181623262218403328 3724303233 8 9 151119132919382616PipeShieldsInc.Note: The maximum hanger spacing shown in Table 4 are derived from load ratings (see Product Data Sheets) of Pipe Shields, Inc. models, assuming weight of standard pipe, and 2 insulation. The customer should be guided by the hanger spacings allowed by the applicable code or the project engineers specifcations before making a selection. Refer to the appropriate Product Data Sheets for additional information such as load rating, compensation for temperature, axial or lateral travel, or restraint, etc.Example: Given: Pipe Diameter: 8 standard weightService: SteamSupport Spacing: 24 - 0Determine: Insulated pipe support model numberMethod: In table 4, for 8 pipe size, fnd the model(s) rated for handling 24- 0 or greater support spacing. In this case, Model A9000 is selected since it is capable of handling 25-0 support spacing. The Index Sheets to Sections A & D indicate some of the differences between models. Check Product Data Sheet for description before making a fnal selection. In this example, if the clearance is above the support limited, Model D6000 might be selected (Section D Index & Product Data Sheet D6000).SERVICE: STEAM, GAS OR AIRAPPLICATION: PIPE SUPPORTED FROM ABOVE IN CLEVIS OR 2-BOLT HANGERInsulated Pipe Support Selection GuideTABLE 4www.pipeshields.com/table4Pipe Size (inches)Forreference: ASME B31.1Pipe Shields Model:Clevis Hanger 2-Bolt HangerA1000 A2000A3000 A4000 A9000D1000 D2000 D4000 D5000D3000 D6000D3100 D6100D3200 D6200D3300 D6300maximum hanger support spacing (feet)1/23/48911121213131511 1/222 1/291213141519202016202222192225252126362933 1/2451516171921212322242324242625262832293130 556810122124263022212020232222212425242432254040555245451416182032353739212121212322222225252525384040385555494460606060 652430424420 2124 403450516060656517PipeShieldsInc.Note: The maximum hanger spacing shown in Table 5 are derived from load ratings (see Product Data Sheets) of Pipe Shields, Inc. models, assuming weight of standard pipe, water, and 2 insulation. The customer should be guided by the hanger spacings allowed by the applicable code or the project engineers specifcations before making a selection. Refer to the appropriate Product Data Sheets for additional information such as load rating, compensation for temperature, axial or lateral travel, or restraint, etc.Example: Given: Pipe Diameter: 8 standard weightService: WaterSupport Spacing: 18 - 0Determine: Insulated pipe support model numberMethod: In table 5, for 8 pipe size, fnd the model(s) rated for handling 18- 0 or greater support spacing. In this case, Model A8200 is selected since it is capable of handling 19-0 support spacing. The Index Sheet to Section A indicates some of the differences between models. Check Product Data Sheet for description before making a fnal selection. If greater support spacings are desired, see Section B (Base Mounted Supports).SERVICE: WATERAPPLICATION: PIPE SUPPORTED FROM BELOW ON PIPE ROLL OR ABOVEInsulated Pipe Support Selection GuideTABLE 5www.pipeshields.com/table5Pipe Size (inches)For refer-ence: ASME B31.1Pipe Shields Model:Commerical Light Industrial w/ Load Distribution PlateA3000A4000A5000A6000 A8000 A8200 A8400maximum hanger support spacing (feet)1/23/477121311 1/222 1/279101113151512 15 1833 1/24512131416121213151215141716161568101217192223129131010122419162322311416182025272830111098211917152825232024303233129161218PipeShieldsInc.Note: The maximum hanger spacing shown in Table 6 are derived from load ratings (see Product Data Sheets) of Pipe Shields, Inc. models, assuming weight of standard pipe, and 2 insulation. The customer should be guided by the hanger spacings allowed by the applicable code or the project engineers specifcations before making a selection. Refer to the appropriate Product Data Sheets for additional information such as load rating, compensation for temperature, axial or lateral travel, or restraint, etc.Example: Given: Pipe Diameter: 8 standard weightService: WaterSupport Spacing: 25 - 0Determine: Insulated pipe support model numberMethod: In table 6, for 8 pipe size, fnd the model (s) rated for handling 25-0 or greater support spacing. In this case, Model A8200 is selected since it is capable of handling 25-0 or 31-0 support spacing. The Index Sheet to Section A indicates some of the differences between models. Check Product Data Sheet for description before making a fnal selection. If greater support spacings are desired, see Section B (Base Mounted Supports).SERVICE: STEAM, GAS OR AIRAPPLICATION: PIPE SUPPORTED FROM BELOW ON PIPE ROLL OR ABOVEInsulated Pipe Support Selection GuideTABLE 6www.pipeshields.com/table6Pipe Size (inches)For refer-ence: ASME B31.1Pipe Shields Model:Commerical Light Industrial w/ Load Distribution PlateA3000A4000A5000A6000 A8000 A8200 A8400maximum hanger support spacing (feet)1/23/489121311 1/222 1/2912131414171815 18 2233 1/245151617191516171919202021212322681012212426301815111320171723363127403850141618203235373913131212222221204039383650505049243036424244485011981816131133292420443919PipeShieldsInc.20PipeShieldsInc.SECTION APRE-INSULATED PIPE SUPPORTSAPPLICATION Commercial and Light IndustrialMostcommercialapplicationsarewellservedbyModels A1000and A2000,whichare recommendedfor useoncommon10-0hangerspaceforsmallborepipesizes (see Selection Guide).However, should the need arise, because of increased hanger spacing or the manner in which the insulated support is mounted, heavier duty supports are available.AsisreadilyseenintheSectionIndexonthefollowingpage,somemodelsaremeantfor installation onlyinaclevishanger,onafatsurface,oronapiperoll.Othermodelsmaybe installed in any two or all three mounting methods.Theloadratings(seeProductDataSheets)refectconsiderationforthemannerinwhicheachofthese models will be mounted.Note:IntheA7000throughA7400SeriesandtheA8000throughA8400Series,thehigherthe model number, the higher the load rating.Wearecommittedtoprovidingthemosteconomicalandappropriateinsulatedpipesupportto satisfy the requirements of the piping system.If your requirements are not covered by the Product Data Sheets in this catalog, please contact us at707-447-5014 or 1-800-538-7007.Please acquaint yourself with the selection guide at the front of this catalog and the section index on the page following this introduction, for assistance in determining the most appropriate support for your application.Introduction: Section AI NTRODUCTI ON 21PipeShieldsInc.PRE-I NSULATED PI PE SUPPORTSCOMMERCIAL AND LIGHT INDUSTRIALMODELPIPE SIZE RANGEPRIMARY APPLICATIONINSTALLED ONDUTYFLAT SURFACECLEVIS HANGERPIPE ROLL HOT COLDA1000 1/2 - 24 X X X LIGHTA2000 1/2 - 24 X X X LIGHTA3000 1/2 - 24 X X X MEDIUMA3000 1/2 - 4 X X MEDIUMA4000 1/2 - 24 X X X MEDIUMA4000 1/2 - 4 X X MEDIUMA5000 2 1/2 - 42 X X X MED/HEAVYA6000 2 1/2 - 42 X X X MED/HEAVYA7000 2 1/2 - 42 X X X HEAVYA7200 6 - 42 X X X HEAVIERA7400 10 - 30 X X X HEAVIESTA8000 2 1/2 - 42 X X X HEAVYA8200 6 - 42 X X X HEAVIERA8400 10 - 30 X X X HEAVIESTA9000 1/2 - 24 X X X HEAVYTO ORDER, specify:1.Quantity202.Pipe Size & Type2IPS3.Insulation Thickness2-1/24.Model NumberA1000EXAMPLE:(20) 2x2-1/2A1000Section A Indexwww.pipeshields.com/a-seriesA1000, A3000, A9000A5000, A7000 - A8400A1000, A3000, A900022PipeShieldsInc.Pipe SizeMAXIMUM LOADRATING (LBS)On FlatSurface(a) (c)In ClevisHanger(b) (c)1/23/413540604045651 1/41 1/2270100125801101402 1/233 1/21501802252002503004562703504003504505508101245050055075010001200141618575600625140016001800202467575020002300TABLE IIron Insulation Thickness CopperPipe 1/2 3/4 1 1 1/2 2 2 1/2 3 3 1/2 4 TubingSize A B A B A B A B A B A B A B A B A B Size O.D.1/2 - 1 1/2 4 24 4 24 4 24 4 24 4 24 4 24 6 24 6 24 6 24 5/8 - 1 5/82 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 2 1/82 1/2 - 4 6 20 6 20 6 20 6 20 6 20 6 20 9 20 9 20 9 20 2 5/8 - 4 1/85 6 20 6 20 6 20 6 20 9 20 9 20 9 20 5 1/86 - 7 6 20 6 20 6 20 6 20 9 16 9 16 9 16 6 1/88 - 10 9 16 9 16 9 16 9 16 9 16 9 16 8 1/8 -10 1/812 - 18 12 16 12 16 12 16 12 16 12 16 12 16 12 1/820 - 24 18 16 18 16 18 16 18 16 18 16 18 16TABLE II "B" = gauge of sheet metal jacketOper.Temp.oFMult.Factor "F"500 0.90750 0.751000 0.501200 0.30TABLE IIIHardware sold separately.Note: For higher load ratings, see A3000, A9000.Theloadratingsrepresentaveragevaluesobtainedinaccordancewithaccepted methods and are subject to normal manufacturingvariations.Dimensionsand ratings are subject to change without notice.a) To develop maximum load rating,widthofsupportsurfaceshouldbeat least1/2of dimension A in Table II.b) To develop maximum load rating, use band, ring or clevis hanger with manufacturers load rating equal to or greater than values shown in Table I.c) To obtain load ratings for operating temperaturesof 500 F and higher, multiply load rating by factor F in Table III.Contact factory for other dimensions, temperatures, and loads.Available in all insulation thicknesses.Application:Model A1000 is designed for use on: Hot water Steam Cold water Air Chilled water Gas Dual temperature VacuumIntended for installation on: Flat surfaces Band, ring or clevis pipe hangerTemperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A1000U)Features: Compact Easy installation Eliminates welding to pipe Overlapping galvanized sheet metal jacket Minimizes heat loss and/or condensation Copper tubing sizes available Other I.D.s and/or O.D.s available on request Clamps available (see G-series) Clevis available (see PTP fg. 83) Performance test results on fle:Available upon request.Material Data: A1000: Applicable PSI spec. doc.: No. 205 Standard Insulation: Calcium silicate asbestos-free, treated with water repellant Jackets: Galvanized steel ASTM A-653 Glue: Industrial contact adhesiveFormal submittal sheets available.Model A1000 Insulated Pipe Support Regular Dutywww.pipeshields.com/a1000AINCHESA1000, A3000, A9000A1000, A3000, A900023PipeShieldsInc.Pipe SizeMAXIMUM LOADRATING (LBS)On FlatSurface(a) (c)In ClevisHanger(b) (c)1/23/413540604045651 1/41 1/2270100125801101402 1/233 1/21501802252002503004562703504003504505508101245050055075010001200141618575600625140016001800202467575020002300TABLE IOper.Temp.oFMult.Factor "F"500 0.90750 0.751000 0.501200 0.30TABLE IIIHardware sold separatelyNote: For higher load ratings, see A4000, A9000.Theloadratingsrepresentaveragevaluesobtainedinaccordancewithaccepted methods and are subject to normal manufacturingvariations.Dimensionsand ratings are subject to change without notice.a) To develop maximum load rating,widthofsupportsurfaceshouldbeat least1/2of dimension A in Table II.b) To develop maximum load rating, use band, ring or clevis hanger with manufacturers load rating equal to or greater than values shown in Table I. c) To obtain load ratings for operating temperaturesof 500F and higher, multiply load rating by factor F in Table III.Contact factory for other dimensions, temperatures, and loads.Available in all insulation thicknesses.Features: Compact Easy installation Eliminates welding to pipe Overlapping galvanized sheet metal jacket Minimizes heat loss and/or condensation Calcium silicate insulation extends 1 beyond the galvanized sheet metal jacket providing for an easier vapor barrier joint with the pipe insulation Copper tubing sizes available Other I.D.s and/or O.D.s available on request Clamps available (see G-series)Application:Model A2000 is designed for use on: Cold water Chilled waterIntended for installation on: Flat surfaces Band, ring or clevis pipe hangerTemperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A2000U)Material Data: A2000: Applicable PSI spec. doc.: No. 205 Insulation: Calcium silicate asbestos-free, treated with water repellant Jackets:Galvanized steel ASTM A-653 Glue:Industrial contact adhesiveFormal submittal sheets available.Iron Insulation Thickness CopperPipe 1/2 3/4 1 1 1/2 2 2 1/2 3 3 1/2 4 TubingSize A B A B A B A B A B A B A B A B A B Size O.D.1/2 - 1 1/2 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 5/8 - 15/82 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 2 1/82 1/2 - 4 6 20 6 20 6 20 6 20 6 20 6 20 9 20 9 20 9 20 2 5/8 - 4 1/85 6 20 6 20 6 20 6 20 9 20 9 20 9 20 5 1/86 - 7 6 20 6 20 6 20 6 20 9 16 9 16 9 16 6 1/88 - 10 9 16 9 16 9 16 9 16 9 16 9 16 8 1/8 -10 1/812 - 18 12 16 12 16 12 16 12 16 12 16 12 16 12 1/820 - 24 18 16 18 16 18 16 18 16 18 16 18 16TABLE II B = gauge of sheet metal jacketModel A2000 Insulated Pipe SupportRegular Duty with Extended Insulationwww.pipeshields.com/a2000AINCHES1"TYPA2000, A4000A1000, A3000, A9000 Clevis available (see PTP fg. 83) Performance test results on fle:Available upon request.24PipeShieldsInc.Oper.Temp.oFMult.Factor "F"500 0.90750 0.751000 0.501200 0.30TABLE IIIHardware sold separatelyNote: For higher load ratings, see A5000, A9000.The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations. Dimensions and ratings are subject to change without notice.a) To develop maximum load rating, width of support surface should be at least 1/2 of dimension A in Table II.b) Divide A in Table II by 6 to fnd maximum allowable travel on pipe roll(+/- from centered position). c) To develop maximum load rating, use band, ring or clevis hanger with manufacturers load rating equal to or greater than values shown in Table I.d) To obtain load ratings for operating temperatures of 500F and higher, multiply load rating by factor F in Table III.Contact factory for other dimensions, temperatures, and loads.Available in all insulation thicknesses.Application:Model A3000 is designed for use on: Hot water Steam Cold water Air Chilled water Gas Dual t emperature VacuumIntended for installation on: Flat surfaces Pipe rolls Band, ring or clevis pipe hanger Temperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A3000U)Features: Compact Easy installation Eliminates welding to pipe Overlapping galvanized sheet metal jacket Minimizes heat loss and/or condensation Double thickness bottom jacket for added structural strength and abrasive wear resistance Copper tubing sizes available Other I.D.s and/or O.D.s available on request Clamps available (see G-series) Clevis available (see PTP fg. 83)Performance test results on fle:Available upon request.Material Data: A3000: Applicable PSI spec. doc.: No. 205 Insulation: Calcium silicate asbestos-free, treated with water repellant Jackets: Galvanized Steel ASTM A-653 Glue: Industrial contact adhesiveFormal submittal sheets availablePipe SizeMAXIMUM LOADRATING (LBS)On FlatSurface(a) (d)On PipeRoll(b) (d)In Ringor Clevis Hanger(c) (d)1/23/414045653540604550701 1/41 1/228011014070100125901201552 1/233 1/2416520025030015018022527022027532537556400450SeeA50004755758101250052557580011001300141618600625650150017001900202470077521002400TABLE IIron Insulation Thickness CopperPipe 1/2 3/4 1 1 1/2 2 2 1/2 3 3 1/2 4 TubingSize A B A B A B A B A B A B A B A B A B Size O.D.1/2 - 1 1/2 4 24 4 24 4 24 4 24 4 24 4 24 6 24 6 24 6 24 5/8 -1 5/82 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 2 1/82 1/2 - 4 6 20 6 20 6 20 6 20 6 20 6 20 9 20 9 20 9 20 2 5/8 - 4 1/85 6 20 6 20 6 20 6 20 9 20 9 20 9 20 5 1/86 - 7 6 20 6 20 6 20 6 20 9 16 9 16 9 16 6 1/88 - 10 9 16 9 16 9 16 9 16 9 16 9 16 8 1/8 -10 1/812 - 18 12 16 12 16 12 16 12 16 12 16 12 16 12 1/820 - 24 18 16 18 16 18 16 18 16 18 16 18 16TABLE II"B" = gauge of sheet metal jacket(bottom jac ket approx. 2 X ga. of top jacket)Model A3000 Insulated Pipe SupportExtra HeavyBottom Jacketwww.pipeshields.com/a3000AINCHESA1000, A3000, A9000A1000, A3000, A900025PipeShieldsInc.Oper.Temp.oFMult.Factor "F"500 0.90750 0.751000 0.501200 0.30TABLE IIIHardware sold separatelyNote: For higher load ratings, see A6000, A9000.The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations. Dimensions and ratings are subject to change without notice.a) To develop maximum load rating, width of support surface should be at least 1/2 of dimension A in Table II.b) Divide A in Table II by 6 to fnd maximum allowable travel on pipe roll (+/- from centered position). c) To develop maximum load rating, use band, ring or clevis hanger with manufacturers load rating equal to or greater than values shown in Table I.d) To obtain load ratings for operating temperatures of 500F and higher, multiply load rating by factor F in Table III.Contact factory for other dimensions, temperatures, and loads.Available in all insulation thicknesses.Application:Model A4000 is designed for use on: Cold water Chilled waterIntended for installation on: Flat surfaces Pipe rolls Band, ring or clevis pipe hangerTemperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A4000U)Features: Compact Easy installation Eliminates welding to pipe Overlapping galvanized sheet metal jacket Double thickness bottom jacket for added structural strength and abrasive wear resistance Minimizes heat loss and/or condensation Calcium silicate insulation extends 1 beyond the galvanized sheet metal jacket providing for an easier vapor barrier joint with the pipe Copper tubing sizes available Other I.D.s and/or O.D.s available on request Clamps available (see G-series) Material Data: A4000: Applicable PSI spec. doc.: No. 205 Insulation: Calcium silicate asbestos-free, treated with water repellant Jackets: Galvanized steel ASTM A-653 Glue: Industrial contact adhesiveFormal submittal sheets availablePipe SizeMAXIMUM LOADRATING (LBS)On FlatSurface(a) (d)On PipeRoll(b) (d)In Ringor Clevis Hanger(c) (d)1/23/414045653540604550701 1/41 1/228011014070100125901201552 1/233 1/2416520025030015018022527022027532537556400450SeeA60004755758101250052557580011001300141618600625650150017001900202470077521002400TABLE IIron Insulation Thickness CopperPipe 1/2 3/4 1 1 1/2 2 2 1/2 3 3 1/2 4 TubingSize A B A B A B A B A B A B A B A B A B Size O.D.1/2 - 1 1/2 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 5/8-1 5/82 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 2 1/82 1/2 - 4 6 20 6 20 6 20 6 20 6 20 6 20 9 20 9 20 9 20 2 5/8 - 4 1/85 6 20 6 20 6 20 6 20 9 20 9 20 9 20 5 1/86 - 7 6 20 6 20 6 20 6 20 9 16 9 16 9 16 6 1/88 - 10 9 16 9 16 9 16 9 16 9 16 9 16 8 1/8 -10 1/812 - 18 12 16 12 16 12 16 12 16 12 16 12 16 12 1/820 - 24 18 16 18 16 18 16 18 16 18 16 18 16TABLE II"B" = gauge of sheet metal jacket(bottom jac ket approx. 2 X ga. of top jacket)Model A4000 Insulated Pipe SupportExtra Heavy Bottom Jacket with extended Insulationwww.pipeshields.com/a4000AINCHES1"TYPA2000, A4000A1000, A3000, A9000 Clevis available (see PTP fg. 83)Performance test results on fle:Available upon request.26PipeShieldsInc.Application:Model A5000 is designed for use on: Hot water Steam Cold water Air Chilled water Gas Dual t emperature VacuumIntended for installation on: Flat surfaces Pipe rollsTemperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A5000U)Features: Compact Easy installation Eliminates welding to pipe Copper tubing sizes available Overlapping galvanized sheet metal jacket Minimizes heat loss and/or condensation Load distribution plate integral with bottom jacket Other I.D.s and/or O.D.s available on requestPerformance test results on fle:Available upon requestMaterial Data: A5000: Applicable PSI spec. doc.: No. 205 Insulation: Calcium silicate asbestos-free, treated with water repellant Jackets: Galvanized steel ASTM A-653 Load distribution Plate:Carbon steel ASTM A-36 Coating: Primer coated or hot-dip galvanizedOther coatings available upon request Glue: Industrial contact adhesiveFormal submittal sheets availableOper.Temp.oFMult.Factor "F"500 0.90750 0.751000 0.501200 0.30TABLE IIContact factory for other dimensions, temperatures, and loads. Available in all insulation thicknesses.Pipe SizeMAXIMUM LOADRATING (LBS)A B CMax. AxialTravel (inches) onPipe Roll+/-On FlatSurface(a) (b)On PipeRoll(b)2 1/233 1/22002503001802252709996661/41/41/42224563504505003154004509996661/41/41/42228101262565092555057582599126691/41/43/822314161810001100120090097510751212129993/81/21/23332024301300140015001150125013501212129991/23/43/4333364215001500135013501212993/43/433TABLE IHardware sold separatelyNote: For higher load ratings, see A7000The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.Dimensions and ratings are subject to change without notice.Contact fac tory for current information.a) To develop maximum load rating, width of support surf ace should be at least 1/2 of dimension B in Table I.b) To obtain load ratings for operating temperatures of 500 oF and higher, multiply maximum load rating by factor F in Table II.Model A5000 Insulated Pipe SupportWith loaddistribution platewww.pipeshields.com/a5000AINCHESBC THK.A5000, A7000 - A8400A5000, A7000 - A840027PipeShieldsInc.Application:Model A6000 is designed for use on: Cold water Chilled waterIntended for installation on: Flat surfaces Pipe rollsTemperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A6000U)Features: Compact Easy installation Eliminates welding to pipe Copper tubing sizes available Overlapping galvanized sheet metal jacket Minimizes heat loss and/or condensation Load distribution plate integral with bottom jacket Calcium silicate insulation extends 1 beyond the galvanized sheet metal jacket providing for an easier vapor barrier joint with the pipe Other I.D.s and/or O.D.s available on requestPerformance test results on fle:Available upon requestMaterial Data: A6000: Applicable PSI spec. doc.: No. 205 Insulation: Calcium Silicate asbestos-free, treated with water repellant Jackets: Galvanized Steel ASTM A-653 Load distribution Plate:Carbon steel ASTM A-36 Coating : Primer coated or hot-dip galvanizedOther coatings available upon request Glue: Industrial contact adhesiveFormal submittal sheets availableOper.Temp.oFMult.Factor "F"500 0.90750 0.751000 0.501200 0.30TABLE IIContact factory for other dimensions, temperatures, and loads. Available in all insulation thicknesses.Pipe SizeMAXIMUM LOADRATING (LBS)A B CMax. AxialTravel (inches) onPipe Roll+/-On FlatSurface(a) (b)On PipeRoll(b)2 1/233 1/22002503001802252709996661/41/41/42224563504505003154004509996661/41/41/42228101262565092555057582599126691/41/43/822314161810001100120090097510751212129993/81/21/23332024301300140015001150125013501212129991/23/43/4333364215001500135013501212993/43/433TABLE IHardware sold separatelyNote: For higher load ratings, see A7000The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.Dimensions and ratings are subject to change without notice.Contact fac tory for current information.a) To develop maximum load rating, width of support surf ace should be at least 1/2 of dimension B in Table I.b) To obtain load ratings for operating temperatures of 500 oF and higher, multiply maximum load rating by factor F in Table II.Model A6000 Insulated Pipe SupportWith load distribution plate with exterior Insulationwww.pipeshields.com/a6000AINCHESBC THK.1"TYPA6000A5000, A7000 - A840028PipeShieldsInc.Application:Model A7000 is designed for use on: Hot water Steam Cold water Air Chilled water Gas Dual t emperature VacuumIntended for installation on: Flat surfaces Pipe rolls, see A8000 Clevis hangers, see A9000Temperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A7000U)Features: Compact Easy installation Eliminates welding to pipe Copper tubing sizes available Minimizes heat loss and/or condensation Insulating structural inserts for load transfer Overlapping galvanized sheet metal jacket Load distribution plate integral with bottom jacket Other I.D.s and/or O.D.s available on requestPerformance test results on fle:Available upon requestMaterial Data: A7000: Applicable PSI spec. doc.: No. 205 Insulation: Calcium silicate asbestos-free, treated with water repellant Jackets: Galvanized steel ASTM A-653 Structural Inserts:High-density calcium silicate asbestos-free, treated with water repellant. Load distribution Plate:Carbon steel ASTM A-36 Coating: Primer coated or hot-dip galvanizedOther coatings available upon request Glue: Industrial contact adhesiveFormal submittal sheets available Note: For higher load ratings, see A7200The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. Dimensions and ratings are subj ect to change without notice. Contact factory for current information.a) To develop maximum load rating, width of support sur face should be at least 1/2 of dimension B in Table I.Contact factory for other dimensions, temperatures, and loads.Available in all insulationthicknesses.Pipe SizeMAXIMUMLOAD RTG. (LBS)A B C On FlatSurface (a)2 1/233 1/22503003506663331/41/41/44564005005506663331/41/41/48101270087516006993661/43/83/81416181650185020009996663/81/21/22024302100230025009996661/23/43/436422500250099663/43/4TABLE IModel A7000 Insulated Pipe SupportHeavy Duty with load bearing platewww.pipeshields.com/a7000AINCHESBC THK.A5000, A7000 - A8400A5000, A7000 - A840029PipeShieldsInc.Application:Model A7200 is designed for use on: Hot water Steam Cold water Air Chilled water Gas Dual t emperature VacuumIntended for installation on: Flat surfaces Pipe rolls, see A8200 Clevis hangers, see A9000Temperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A7200U)Features: Compact Easy installation Eliminates welding to pipe Copper tubing sizes available Minimizes heat-loss and/or condensation Insulating structural inserts for load transfer Overlapping galvanized sheet metal jacket Load distribution plate integral with bottom jacket Other I.D.s and/or O.D.s available on requestPerformance test results on fle:Available upon requestMaterial Data: A7200: Applicable PSI spec. doc.: No. 205 Insulation: Calcium silicate asbestos-free, treated with water repellant Jackets: Galvanized steel ASTM A-653 Structural Inserts:High-density calcium silicate asbestos-free, treated with water repellant Load distribution Plate:Carbon steel ASTM A-36 Coating: Primer coated or hot-dip galvanized Other coatings available upon request Glue: Industrial contact adhesiveFormal Submittal Sheets availableNote: For higher load ratings, see A7400, B1100The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. Dimensions and ratings are subj ect to change without notice. Contact factory for current information.a) To develop maximum load rating, width of support sur face should be at least 1/2 of dimension B in Table I.Pipe SizeMAXIMUMLOAD RTG. (LBS)A B COn FlatSurface (a)68101000125015509996661/21/25/81214162250278033009996665/85/83/41820243600380041009996663/43/41303642450045004500999666111TABLE IContact factory for other dimensions, temperatures, and loads.Available in all insulationthicknesses.Model A7200 Insulated Pipe SupportHeavy Duty with load bearing platewww.pipeshields.com/a7200AINCHESBC THK.A5000, A7000 - A8400A5000, A7000 - A840030PipeShieldsInc.Application:Model A7400 is designed for use on: Hot water Steam Cold water Air Chilled water Gas Dual t emperature VacuumIntended for installation on: Flat surfaces Pipe rolls, see A8400 Clevis hangers, see A9000Temperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A7400U)Features: Compact Easy installation Eliminates welding to pipe Copper tubing sizes available Minimizes heat-loss and/or condensation Insulating structural inserts for load transfer Overlapping galvanized sheet metal jacket Load distribution plate integral with bottom jacket Other I.D.s and/or O.D.s available on requestPerformance Test Results on File:Available upon requestMaterial Data: A7400: Applicable PSI spec. doc.: No. 205. Insulation: Calcium Silicate asbestos-free, treated with water repellant Jackets: Galvanized Steel ASTM A-653 Structural Inserts:High-density calcium silicate asbestos-free, treated with water repellant. Load distribution Plate:Carbon steel ASTM A-36 Coating: Primer coated or hot-dip galvanized Other coatings available upon request Glue: Industrial contact adhesiveFormal Submittal Sheets availableNote: For higher load ratings, see B1200The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. Dimensions and ratings are subj ect to change without notice. Contact factory for current information.a) To develop maximum load rating, width of support sur face should be at least 1/2 of dimension B in Table I.Pipe SizeMAXIMUMLOAD RTG. (LBS)A B COn FlatSurface (a)1012142100340039009996663/43/43/4161820440048005100999666111243036425500550065007500999966661111TABLE IContact factory for other dimensions, temperatures, and loads.Available in all insulationthicknesses.Model A7400 Insulated Pipe SupportHeavy Duty with load bearing platewww.pipeshields.com/a7400AINCHESBC THK.A5000, A7000 - A8400A5000, A7000 - A840031PipeShieldsInc.Application:Model A8000 is designed for use on: Hot water Steam Cold water Air Chilled water Gas Dual t emperature VacuumIntended for installation on: Flat surfaces, see A7000 Pipe rolls Clevis hangers, see A9000Temperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A8000U)Features: Compact Easy installation Eliminates welding to pipe Copper tubing sizes available Minimizes heat loss and/or condensation Insulating structural inserts for load transfer Overlapping galvanized sheet metal jacket Load distribution plate integral with bottom jacket Other I.D.s and/or O.D.s available on requestPerformance test results on fle:Available upon requestMaterial Data: A8000: Applicable PSI spec. doc.: No. 205 Insulation: Calcium silicate asbestos-free, treated with water repellant Jackets: Galvanized steel ASTM A-653 Structural Inserts:High-density calcium silicate asbestos-free, treated with water repellant Load distribution Plate:Carbon steel ASTM A-36 Coating: Primer coated or hot-dip galvanized.Other coatings available upon request Glue: Industrial contact adhesiveFormal submittal sheets availableHardwaresoldseparatelyNote: For higher load ratings, see A8200The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. Dimensions and ratings are subj ect to change without notice. Contact factory for current information.Pipe SizeMAXIMUMLOADRTG. (LBS)A B CMax. AxialTravel (Inches) onPipe RollOnPipe Roll2 1/233 1/22252503009996661/41/41/42224563504505009996661/41/41/4222810126258751400912126991/43/83/82441416181475165018001212129993/81/21/24442024301875205022501212129991/23/43/44443642225022501212993/43/444TABLE IContact factory for other dimensions, temperatures, and loads.Available in all insulationthicknesses.Model A8000 Insulated Pipe SupportHeavy Duty with load bearing platewww.pipeshields.com/a8000AINCHESBC THK.A5000, A7000 - A8400A5000, A7000 - A840032PipeShieldsInc.Application:Model A8200 is designed for use on: Hot water Steam Cold water Air Chilled water Gas Dual t emperature VacuumIntended for installation on: Pipe rolls Flat surfaces, see A7200 Clevis hangers, see A9000Temperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A8200U)Features: Compact Easy installation Eliminates welding to pipe Copper tubing sizes available Minimizes heat loss and/or condensation Insulating structural inserts for load transfer Overlapping galvanized sheet metal jacket Load distribution plate integral with bottom jacket Other I.D.s and/or O.D.s available on requestPerformance test results on fle:Available upon requestMaterial Data: A8200: Applicable PSI spec. doc.: No. 205. Insulation: Calcium silicate asbestos-free, treated with water repellant Jackets: Galvanized steel ASTM A-653 Structural Inserts:High-density calcium silicate asbestos-free, treated with water repellant Load distribution Plate:Carbon steel ASTM A-36 Coating: Primer coated or hot-dip galvanized Other coatings available upon request Glue: Industrial contact adhesiveFormal submittal sheets availableHardwaresoldseparatelyNote: For higher load ratings, see A8400, B1100The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. Dimensions and ratings are subj ect to change without notice. Contact factory for current information.Contact factory for other dimensions, temperatures, and loads.Available in all insulationthicknesses.Pipe SizeMAXIMUMLOADRTG. (LBS)A B CMax. AxialTravel (Inches) onPipe RollOnPipe Roll6810900112513751212129991/21/25/83331214162550265029501212129995/85/83/43331820243200337536751212129993/43/41333303642405040504050121212999111333TABLE IModel A8200 Insulated Pipe SupportHeavy Duty with load bearing platewww.pipeshields.com/a8200AINCHESBC THK.A5000, A7000 - A8400A5000, A7000 - A840033PipeShieldsInc.Application:Model A8400 is designed for use on: Hot water Steam Cold water Air Chilled water Gas Dual t emperature VacuumIntended for installation on: Pipe rolls Flat surfaces, see A7400 Clevis hangers, see A9000Temperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A8400U)Features: Compact Easy installation Eliminates welding to pipe Copper tubing sizes available Minimizes heat loss and/or condensation Insulating structural inserts for load transfer Overlapping galvanized sheet metal jacket Load distribution plate integral with bottom jacket Other I.D.s and/or O.D.s available on requestPerformance test results on fle:Available upon requestMaterial Data: A8400: Applicable PSI spec. doc.: No. 205 Insulation: Calcium silicate asbestos-free, treated with water repellant Jackets: Galvanized steel ASTM A-653 Structural Inserts:High-density calcium silicate asbestos-free, treated with water repellant Load distribution Plate:Carbon steel ASTM A-36 Coating: Primer coated or hot-dip galvanized Other coatings available upon request Glue: Industrial contact adhesiveFormal submittal sheets availableHardwaresoldseparatelyNote: For higher load ratings, see B1200The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. Dimensions and ratings are subj ect to change without notice. Contact factory for current information.Pipe SizeMAXIMUMLOADRTG. (LBS)A B CMax. AxialTravel (Inches) onPipe RollOnPipe Roll1012141875340035001212129991112 1/42 1/42 1/41618203950430045501212129991112 1/42 1/42 1/424303642495054506450745012121212999911112 1/42 1/42 1/42 1/4TABLE IContact factory for other dimensions, temperatures, and loads.Available in all insulationthicknesses.Model A8400 Insulated Pipe SupportHeavy Duty with load bearing platewww.pipeshields.com/a8400AINCHESBC THK.A5000, A7000 - A8400 A5000, A7000 - A840034PipeShieldsInc.Application:Model A9000 is designed for use on: Hot water Steam Cold wwater Air Chilled water Gas Dual t emperature VacuumIntended for installation on: Band, ring or clevis pipe hangers Flat surfaces, see A7000 Pipe rolls, see A8000Temperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., A9000U)Features: Compact Easy installation Eliminates welding to pipe Overlapping galvanized sheet metal jacket Minimizes heat loss and/or condensation Insulating structural inserts for load transfer Copper tubing available Other I.D.s and/or O.D.s available on requestPerformance test results on fle:Available upon requestMaterial Data: A9000: Applicable PSI spec. doc.: No. 205 Insulation: Calcium silicate asbestos-free, treated with water repellant Jackets: Galvanized steel ASTM A-653 Structural Inserts:High-density calcium silicate asbestos-free, treated with water repellant Glue: Industrial contact adhesiveFormal submittal sheets availableIron InsulationThickness CopperPipe 1/2 3/4 1 1 1/2 2 2 1/2 3 3 1/2 4 TubingSize A B A B A B A B A B A B A B A B A B Size O.D.1/2 - 1 1/2 4 24 4 24 4 24 4 24 4 24 4 24 6 24 6 24 6 24 5/8-1 5/82 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 6 24 2 1/82 1/2 - 4 6 20 6 20 6 20 6 20 6 20 6 20 9 20 9 20 9 20 2 5/8 - 4 1/85 6 20 6 20 6 20 6 20 9 20 9 20 9 20 5 1/86 - 7 6 20 6 20 6 20 6 20 9 16 9 16 9 16 6 1/88 - 10 9 16 9 16 9 16 9 16 9 16 9 16 8 1/8 -10 1/812 - 18 12 16 12 16 12 16 12 16 12 16 12 16 12 1/820 - 24 18 16 18 16 18 16 18 16 18 16 18 16TABLE II"B" = gauge of sheet metal jacket(bottom jac ket approx. 2 X ga. of top jacket)Pipe SizeMAXIMUMLOAD RTG. (LBS)In Ringor Clevis Hanger (a)1/2 503/4 551 801 1/4 1001 1/2 1302 1752 1/2 2503 3003 1/2 3504 4005 5506 6008 90010 120012 145014 165016 190018 215020 240024 2750TABLE IContact factory for other dimensions, temperatures, and loads.Available in all insulationthicknesses.Hardware sold separatelyNote: For higher load ratings, see D1000, D3000The load ratings represent average values obtained in accordance with accepted methods and are subject to normal manufacturing variations. Dim ensions and ratings are subject to change without notice.a) To develop maximum load rating use band, ring or clevis hanger with manufacturersload rating equal to or greater than values shown in Table I.Model A9000 Insulated Pipe SupportHeavy Duty for use with rod hangerswww.pipeshields.com/a9000AINCHESA1000, A3000, A9000A1000, A3000, A900035PipeShieldsInc.36PipeShieldsInc.SECTION BPRE-INSULATED PIPE SUPPORTS - Base MountedAPPLICATION Heavy Industrial and Large HVAC Distribution SystemsFeatures: Accommodation of thermal movement Provision or lateral guide or restraint Minimization of side friction loads Wide range of maximum load requirements for each pipe sizeNote: Ineachmodelnumberseries(forexample:B1000throughB1300Series),thehigherthe model number, the higher the load rating.Models B1000 - B1300Sliding supports free to travel axially and laterally.Models B2000 - B2300Same as B1000 - B1300 except can accommodate greater axial travel. Models B3000 - B3300Sliding supports with lateral guides.Models B4000 - B4300Same as B3000 - B3300 except can accommodate greater axial travel. Models B5000 - B5300Same as B1000 - B1300 except can accommodate greater lateral travel. Models B6000 - B6300Same as B2000 - B2300 except can accommodate greater lateral travel.Models B7000 - B7300Same as B3000 - B3300 except with reduced vertical load ratings to allow greater lateral loads.Minimum side friction is assured by the addition of lateral slide pads.Models B8000 - B8300Same as B4000 - B4300 except with reduced vertical load ratings to allow greater lateral loads.Minimum side friction is assured by the addition of lateral slide pads.To meet special thermal movement requirements, Pipe Shields, Inc. has provided supports that have accommodated axial travels in excess of fve (5) feet. By modifying our standard pipe support concept with combinations of structural insulation materials, steel base andstrap design, and slide plate confguration, we can readily and economically respond to virtually any pipe support requirement.If your requirements are not covered by the Product Data Sheets in this catalog, please contact us at707-447-5014 or 1-800-538-7007.Please acquaint yourself with the selection guide at the front of this catalog and the section index on the page following this introduction, for assistance in determining the most appropriate support for your application.Introduction: Section BI NTRODUCTI ON 37PipeShieldsInc.MODELPIPE SIZE RANGETRAVEL (INCHES) +/-LATERAL GUIDEDUTYAXIAL LATERALB1000 1/2 - 42 1.5 1.5 NO MEDIUMB1100 1/2 - 42 1.5 1.5 NO HEAVYB1200 1/2 - 42 1.5 1.5 NO HEAVIERB1300 1/2 - 42 1.5 1.5 NO HEAVIESTB2000 1/2 - 42 4.5 1.5 NO MEDIUMB2100 1/2 - 42 4.5 1.5 NO HEAVYB2200 1/2 - 42 4.5 1.5 NO HEAVIERB2300 1/2 - 42 4.5 1.5 NO HEAVIESTB3000 1/2 - 42 1.5 0 YES MEDIUMB3100 1/2 - 42 1.5 0 YES HEAVYB3200 1/2 - 42 1.5 0 YES HEAVIERB3300 1/2 - 42 1.5 0 YES HEAVIESTB4000 1/2 - 42 4.5 0 YES MEDIUMB4100 1/2 - 42 4.5 0 YES HEAVYB4200 1/2 - 42 4.5 0 YES HEAVIERB4300 1/2 - 42 4.5 0 YES HEAVIESTSection B IndexPRE-I NSULATED PI PE SUPPORTSHEAVY INDUSTRIAL - BASE MOUNTEDwww.pipeshields.com/b-seriesB1000B2000B3000B400038PipeShieldsInc.MODELPIPE SIZE RANGETRAVEL (INCHES) +/-LATERAL GUIDEDUTY AXIAL LATERALB5000 1/2 - 42 1.5 1.5 - 4.5 NO MEDIUMB5100 1/2 - 42 1.5 1.5 - 4.5 NO HEAVYB5200 1/2 - 42 1.5 1.5 - 4.5 NO HEAVIERB5300 1/2 - 42 1.5 1.5 - 4.5 NO HEAVIESTB6000 1/2 - 42 4.5 1.5 - 4.5 NO MEDIUMB6100 1/2 - 42 4.5 1.5 - 4.5 NO HEAVYB6200 1/2 - 42 4.5 1.5 - 4.5 NO HEAVIERB6300 1/2 - 42 4.5 1.5 - 4.5 NO HEAVIESTB7000 1/2 - 42 1.5 0 YES MEDIUMB7100 1/2 - 42 1.5 0 YES HEAVYB7200 1/2 - 42 1.5 0 YES HEAVIERB7300 1/2 - 42 1.5 0 YES HEAVIESTB8000 1/2 - 42 4.5 0 YES MEDIUMB8100 1/2 - 42 4.5 0 YES HEAVYB8200 1/2 - 42 4.5 0 YES HEAVIERB8300 1/2 - 42 4.5 0 YES HEAVIESTSection B IndexPRE-I NSULATED PI PE SUPPORTSHEAVY INDUSTRIAL - BASE MOUNTEDwww,pipeshields.com/b-seriesB5000B6000B7000B800039PipeShieldsInc.PIPESIZEINSULATION THICKNESS3 1/2 4 1/2 5 1/2 6 6 1/2 7 7 1/2 8 8 1/2 9 9 1/2 103 6 6 8 8 8 10 12 12 12 12 13 143 1/2 6 6 8 8 8 10 12 12 12 12 13 144 6 6 8 8 8 10 12 12 12 12 13 145 6 6 8 8 8 10 12 12 12 12 13 146 6 6 8 8 8 10 12 12 12 12 13 148 6 8 8 8 10 10 12 12 12 12 13 1410 6 8 8 8 10 10 12 12 12 12 13 1412 6 8 8 8 10 10 12 12 12 12 13 1414 6 8 8 8 10 10 12 12 12 12 13 1416 6 8 8 10 10 10 12 12 12 12 13 1418 6 8 8 10 10 10 12 12 12 12 13 1420 6 8 8 10 10 10 12 12 12 12 13 1424 6 8 8 10 10 10 12 12 12 12 13 1430 8 8 10 10 10 10 12 12 12 12 13 1436 8 8 10 10 10 10 12 12 12 12 13 1442 8 8 10 10 10 10 12 12 12 12 13 14THE FOLLOWING TABLE ILLUSTRATES BOTTOM-O F-PIPE TO TOP-OF-STEEL DIMENSIONS(DIMENSION B) FOR B MODEL PIPE SUPPORTS AND C M ODEL PIPE ANCHORS FOR INTERMEDIATE INSULATION THICKNESSCOMMENTS:The insulation thickness shown on the Product Data Sheets in Sections B and C are in even 1 increments. The table shown here provides Bottom-of-Pipe to Top-of-Steel dimensions (B Dimensions) for 3 1/2, 4 1/2, 5 1/2, 6, 6 1/2, 7, 7 1/2, 8, 8 1/2, 9, 9 1/2, and 10 insulation thicknesses. Check with factory if you require a B dimension other than those shown in this table.TO ORDER, specify:1.Quantity202.Pipe Size & Type18IPS3.Insulation Thickness24.Model NumberB1000EXAMPLE: (20) 18x2 B1000Section B Indexwww.pipeshields.com/b-series40PipeShieldsInc.Application:Model B1000 is designed for use on: Hot water Steam Cold water Air Chilled water Gas Dual temperature VacuumIntended for installation on: Flat surfacesTemperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., B1000U)Features: All pipe sizes Easy installation Eliminates welding to pipe Overlapping galvanized sheet metal jacket Insulating structural inserts for load transfer Stainless steel to UHMW polyethylene slide Other I.D.s and/or O.D.s available on request Factory mounted polyethylene slide pad on steel mounting platePerformance test results on fle:Available upon requestMaterial Data: B1000: Applicable PSI spec. doc.: No. 209 Insulation:Calcium silicate asbestos-free, treated with water repellant Jackets: Galvanized steel ASTM A-653 Glue: Industrial contact adhesive Structural Inserts: High-density calcium silicate asbestos free, treated with water repellant Steel Straps/Base: Carbon Steel ASTM A-36 Fasteners: ASTM A-307 plated Slide Pad: UHMW Polyethylene (PTFE optional) Coating: Primer coated or hot dipped galvanized Other coatings available upon requestFormal Submittal Sheets availablePipeSizeVert.LoadInsul. Thk. = 1" Insul. Thk. = 1-1/2" Insul. Thk. = 2" Insul. Thk. = 2-1/2" Insul. Thk. = 3" Insul. Thk. =4" Insul. Thk. = 5"B C E B C E B C E B C E B C E B C E B C E1/23/411 1/214017522532544441.51.5223.253.253.8754.3754444222.52.54.3754.3754.8755.544442.52.5345.3755.3755.937744444444.5777866664.54.54.55.5888966666.56.56.57.510101011.258888888912.12512.12512.2513.2522 1/23437546053084044442.52.53455.56.0627.2544443444.56.06257.1257.1258.25444444.54.55.578.1258.1259.2544444.55.55.56.589.1259.12510.2566665.56.56.57.59.12510.12510.12511.37566667.588911.2512.2512.37513.375888899.59.510.513.2514.514.62515.62556810105012751700200044444.55.57.598.259.2511.62513.62544445.56.589.59.2510.2512.62514.87544446.57.5910.510.2511.37513.62515.87544667.589.51111.37512.62514.87516.87566668910.51212.37513.62515.87518.12566669.510.5121314.87515.87517.87520.125888811121314.516.87517.87520.12522.125121416182200250029003200444410.51112.51416.12517.12519.12521.375444411121314.517.12518.12520.12522.37544661212.51415.518.12519.12521.37523.375666612.51314.51619.12520.12522.37524.3756666131415.516.520.12521.12523.37525.375668814.515.516.51822.12523.12525.37527.37588881616.51819.524.12525.12527.37529.3752024303642340036004700550062004444415.51822.526.53123.37527.37533.62539.62546.1254466616192327.531.524.37528.37534.62541.12547.1256666616.519.5242832.525.37529.37535.62542.12548.1256666617.520.524.528.53326.37530.37536.62543.12549.1256666618212529.533.527.37531.37537.62544.12550.1258888819.522.526.5313529.37533.37539.62546.12552.1258888821242832.536.531.37535.37541.62548.12554.125Contact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations. Dimensions and ratings are subject to change without notice.Note: For higher load ratings, see: B1100 - For greater axial travel, see: B2000 - For lateral restraint, see: B3000 - For lateral travel, see: B5000.Model B1000 Sliding Insulated Pipe SupportHeavy Duty,Base Mountedwww,pipingtech.com/b1000E 9"C3"6"3"STEEL MOUNTING PLATEPOLYETHYLENE SLIDE PAD1 1/2" MAX.AXIAL TRAVEL1/2" MAX.LATERAL TRAVELBB.O.P.T.O.S.PIPEB1000EC3"6"9"1 1/2" MAX.AXIAL TRAVEL3"STEEL MOUNTING PLATEPOLYETHYLENE SLIDE PADBB.O.P.T.O.S. "L" MAX.LATERAL TRAVELPIPEB500041PipeShieldsInc.Application:Model B1100 is designed for use on: Hot water Steam Cold water Air Chilled water Gas Dual temperature VacuumIntended for installation on: Flat surfacesTemperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., B1100U)Features: All pipe sizes Easy installation Eliminates welding to pipe Overlapping galvanized sheet metal jacket Insulating structural inserts for load transfer Stainless steel to UHMW polyethylene slide Other I.D.s and/or O.D.s available on request Factory mounted polyethylene slide pad on steel mounting platePerformance test results on fle:Available upon request.Material Data: B1100: Applicable PSI spec. doc.: No. 209. Insulation:Calcium silicate asbestos-free, treated with water repellant. Jackets: Galvanized steel ASTM A-653. Glue: Industrial contact adhesive Structural Inserts: High-density calcium silicate asbestos free, treated with water repellant. Steel Straps/Base: Carbon steel ASTM A-36. Fasteners: ASTM A-307 plated. Slide Pad: UHMW Polyethylene (PTFE optional). Coating: Primer coated or hot dipped galvanized. Other coatings available upon request.Formal submittal sheets availableContact factory for other dimensional, temperature, load, or axial travel requirements. Available in all insulation thickness.The load ratings represent average values obtained in accordance with accepted test methods and are subject to normal manufacturing variations.Dimensions and ratings are subject to change without notice.Note: For higher load ratings, see: B1200 - For greater axial travel, see: B2100 - For lateral restraint, see: B3100 - For lateral travel, see: B5100.PipeSizeVert.LoadInsul. Thk. = 1" Insul. Thk. = 1-1/2" Insul. Thk. = 2" Insul. Thk. = 2-1/2" Insul. Thk. = 3" Insul. Thk. =4" Insul. Thk. = 5"B C E B C E B C E B C E B C E B C E B C E1/23/411 1/228035045065044441.51.5223.253.253.8754.54444222.52.54.3754.37555.544442.52.5345.3755.3756.0627.12544444444.57778.12566664.54.54.55.58889.12566666.56.56.57.510101011.258888888912.12512.2512.2513.2522 1/2347509201060168044442.52.53455.56.1877.2544443444.56.06257.1257.1258.25444444.54.55.57.1258.1258.1259.2544444.55.55.56.58.1259.1259.12510.2566665.56.56.57.59.12510.12510.12511.37566667.588911.2512.2512.37513.375888899.59.510.513.2514.514.62515.62556810210025503400400044444.55.57.598.59.511.62513.87544445.56.589.59.510.512.62515.12544446.57.5910.510.511.62513.62516.12544667.589.51111.62512.62514.87517.12566668910.51212.62513.62515.87518.12566669.510.5121314.87515.87518.12520.125888811121314.516.87517.87520.12522.125121416184400500058006400444410.51112.51416.12517.12519.37521.375444411121314.517.12518.12520.37522.37544661212.51415.518.12519.12521.37523.375666612.51314.51619.12520.12522.37524.3756666131415.516.520.12521.12523.37525.375668814.515.516.51822.12523.12525.37527.37588881616.51819.524.12525.12527.37529.375202430364268007200940011000124004444415.51822.526.53123.37527.37533.62540.12546.1254466616192327.531.524.37528.37534.62541.12547.1256666616.519.5242832.525.37529.37535.62542.12548.1256666617.520.524.528.53326.37530.37536.62543.12549.1256666618212529.533.527.37531.37537.62544.12550.1258888819.522.526.5313529.37533.37539.62546.12552.1258888821242832.536.531.37535.37541.62548.12554.125Model B1100 Sliding Insulated Pipe SupportHeavy Duty,Base Mountedwww.pipeshields.com/b1100E 9"C3"6"3"STEEL MOUNTING PLATEPOLYETHYLENE SLIDE PAD1 1/2" MAX.AXIAL TRAVEL1/2" MAX.LATERAL TRAVELBB.O.P.T.O.S.PIPEB1000EC3"6"9"1 1/2" MAX.AXIAL TRAVEL3"STEEL MOUNTING PLATEPOLYETHYLENE SLIDE PADBB.O.P.T.O.S. "L" MAX.LATERAL TRAVELPIPEB500042PipeShieldsInc.Application:Model B1200 is designed for use on: Hot water Steam Cold water Air Chilled water Gas Dual temperature VacuumIntended for installation on: Flat surfacesTemperature Range: Standard: +40F to +1200F CalSil InsulationNote: Up to 1800F available upon request.Cryogenic: -275F to +275F Urethane Insulation. Add U after the model number (i.e., B1200U)Features: All pipe sizes Easy installation Eliminates welding to pipe Overlapping galvanized sheet metal jacket Insulating structural inserts for load transfer Stainless steel to UHMW polyethylene slide Other I.D.s and/or O.D.s available on request Factory mounted polyethylene slide pad on steel mounting platePerformance test results on sile:Available upon request.Material Data: B1200: Applicable PSI spec. doc.: No. 209. Insulation:Calcium silicate asbestos-free, treated with water repellant. Jackets: Galvanized steel ASTM A-653. Glue: Industrial contact adhesive Structural Inserts: High-density calcium silicate asbestos free, treated with water repellant. Steel Straps/Base: Carbon steel ASTM A-36. Fasteners: ASTM A-307 plated. Slide Pad: UHMW Polyethylene (PTFE optional). Coating: Primer coated or hot dipped galvanized Other coatings available upon requestFormal Submittal Sheets availablePipeSizeVert.LoadInsul. Thk. = 1" Insul. Thk. = 1-1/2" Insul. Thk. = 2" Insul. Thk. = 2-1/2" Insul. Thk. = 3" Insul. T