+ All Categories
Home > Documents > plantas starbucks

plantas starbucks

Date post: 15-Jan-2016
Category:
Upload: maria-de-jesus-soberanis-perez
View: 47 times
Download: 10 times
Share this document with a friend
Description:
plantas starbucks
Popular Tags:
35
DRAWING INDEX PROJECT DESCRIPTION TITLE VICINITY MAP LOCATION MAP Clemson University Starbucks Coffee Company ARCHITECTS PROJECT NO. 0816.01 This project is a renovation and refurbishment of an existing student union gaming lounge space, to be replaced with a Starbucks Brand retail food service venue. The extents of the work includes demolition of existing partitions, ceilings, flooring, furniture and interior wall finishes and construction of new partitions, millwork, ceilings and installation of new finishes and equipment as shown on A/E drawings. MEP systems will be modified as required and shown on A/E construction drawings. The project is located on the first floor of the Harcombe University Center. TRUE PROJECT dwg no. project no. drawn checked project date kenneth w. tipton, jr., aia bryon m. hume, aia darrin l. badon, aia daniel m. zito, aia 449 westmoreland drive baton rouge, louisiana 70806 ph 225.387.0101 fax 225.387.0104 www.tipton-associates.com revisions Clemson University, SC Student Center 113 Union Drive Clemson, SC 29634 8/3/2012 5:20:57 PM G-000 0816.01 DK JP 05-25-2012 Starbucks Coffee Company COVER McKnight Smith Ward Griffin Engineers, Inc. 4223 South Blvd. Charlotte, NC 28209 704-527-2112 X156 mswg.com MEP HARCOMBE DINNING HALL CLEMSON UNIVERSITY General G-000 COVER G-001 General Information G-002 Scope of Work Plan Demolition D-100 Demolition Plan D-200 Demolition Ceiling Plan Architectural A-112 Floor Plan A-113 Penetration Plan A-114 FF and E Plan A-115 Casework Plan A-116 Reflected Ceiling Plan A-117 Floor Finish Plan A-119 Wall Finish Plan A-201 Exterior Elevations A-211 Interior Elevations A-212 Interior Elevations A-501 Partition Types and Wall Details A-502 Ceiling Details A-503 Custom Seating Details A-504 Casework Details A-505 Casework Details A-506 Light Fixture Details A-601 Schedules A-602 Schedules A-801 Enlarged Electrical Plans A-802 Enlarged Plumbing Plans Mechanical M-100 Mechanical Demo Plan M-101 Mechanical Floor Plan M-201 Mechanical Schedules and Details Plumbing P-101 Plumbing Plan P-201 Schedules and Details Electrical E-100 Symbols and Schedules E-101 Symbols and Schedules E-201 Floor Plan - Lighting E-301 Floor Plan - Power E-401 Power Riser Diagram no. description date
Transcript
Page 1: plantas starbucks

DRAWING INDEX

PROJECT DESCRIPTION

TITLE

VICINITY MAP LOCATION MAP

Clemson UniversityStarbucks Coffee Company

ARCHITECTS PROJECT NO. 0816.01

This project is a renovation and refurbishment of an existing student union gaming lounge space, to be replaced with a Starbucks Brandretail food service venue. The extents of the work includes demolition of existing partitions, ceilings, flooring, furniture and interior wallfinishes and construction of new partitions, millwork, ceilings and installation of new finishes and equipment as shown on A/E drawings.MEP systems will be modified as required and shown on A/E construction drawings. The project is located on the first floor of the HarcombeUniversity Center.

TRUE

PROJECTdwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:2

0:57

PM

G-000

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

COVER

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

HARCOMBE DINNING HALLCLEMSON UNIVERSITY

GeneralG-000 COVERG-001 General InformationG-002 Scope of Work Plan

DemolitionD-100 Demolition PlanD-200 Demolition Ceiling Plan

ArchitecturalA-112 Floor PlanA-113 Penetration PlanA-114 FF and E PlanA-115 Casework PlanA-116 Reflected Ceiling PlanA-117 Floor Finish PlanA-119 Wall Finish PlanA-201 Exterior ElevationsA-211 Interior ElevationsA-212 Interior ElevationsA-501 Partition Types and Wall DetailsA-502 Ceiling DetailsA-503 Custom Seating DetailsA-504 Casework DetailsA-505 Casework DetailsA-506 Light Fixture DetailsA-601 SchedulesA-602 SchedulesA-801 Enlarged Electrical PlansA-802 Enlarged Plumbing Plans

MechanicalM-100 Mechanical Demo PlanM-101 Mechanical Floor PlanM-201 Mechanical Schedules and Details

PlumbingP-101 Plumbing PlanP-201 Schedules and Details

ElectricalE-100 Symbols and SchedulesE-101 Symbols and SchedulesE-201 Floor Plan - LightingE-301 Floor Plan - PowerE-401 Power Riser Diagram

no. description date

Page 2: plantas starbucks

WOMEN

BOWLING ALLEY

MECH MEN

ELEV.

STEPUP

STAIR

STEPUP

COURTYARD

STEP

STAIR

UP

STOR COOLER

STEPUP

STAIRUP

STEP STEPUP

STEPUP

UP

RAM

P

STEPUP

STEPUP

ARCADE

STOR

BILLIARDS HALL

RAM

PU

P

DN

OFFICE

MECH

JAN

OFFICE OFFICE

ARCADESTOR

RECEPTION

MUNICIPAL

OFFICE OFFICE OFFICE

MENDOORS TO

SUB-BASEMENT

UNISEX

BREAK ROOM

STORAGE

STOR

OFFICE

CUBICLE

WOMEN

MECH ELEC

STEPUP

CUBICLECUBICLE

CUBICLECUBICLE

COUNTER

COUNTERSERVICESPARKING

COURT

OFFICE

CUBICLE CUBICLE CUBICLE

Owner:

Licensee:

Architect of Record:

MEP Engineer:

StarbucksDesign Manager:

StarbucksDevelopment Manager:

Rex GravesClemson University Dining &Vending Services CoordinatorG06 Sikes HallBox 345376Clemson, SC 29634-5376(864) 656-0761 phone

Jeffery HallARAMARKP.O. Drawer 429Clemson, SC 29633(864) 656-2110 phone(864) 656-2109 fax

Ken TiptonTipton Associates449 Westmoreland DriveBaton Rouge, LA 70806(225) 387-0101 phone(225) 387-0104 fax

Craig ChampionMcKnight Smith Ward GriffinEngineers, Inc.4223 South Blvd.Charlotte, NC 28209(704) 527-2112 phone

Eloisa BustosStarbucks Coffee Company95 Merrick Way, Suite 650Coral Gables, FL 33134(305) 529-5359 phone

Chuck HooverStarbucks Coffee Company1959 N. Peave Haven Road,Suite 316(336) 972-3022 phone(206) 903-2756 fax

3PL Third Party Logistics

A/C Air ConditioningACT Acoustical Ceiling TileADJ AdjustableAFF Above Finished FloorAMP AmpereARCH Architect

BOH Back of House

CAB CabinetCL Center LineCLG CeilingCM Construction ManagerCTR CenterCX CommissioningCXA Commissioning Agent

DEG DegreeDET DetailDIA DiameterDIM DimensionDM Design ManagerDN Down

EA EachEL ElevationEQ EqualEXIST ExistingEXT Exterior

FF&E "Furniture, Fixture, and Equipment"FIO Furnished and Installed by OwnerFLR FloorFOH Front of HouseFT Foot/Feet

G GroundGC General Contractor

HC Hollow CoreHDW HardwareHM Hollow MetalHORIZ HorizontalHR HourHT HeightHVAC "Heating, Ventilating, and Air Conditioning"

ID Inside Diameter

LL Landlord

MAX MaximumMEP "Mechanical, Electrical, and Plumbing"MFR ManufacturerMIN Minimum

NIC Not in ContractNL Night LightNTS Not to Scale

OC On CenterOD Outside DiameterOF/CI Owner Furnished/Contractor InstalledOF/OI Owner Furnished/Owner Installed

PD Production DesignerPLC PlacePM Project Manager

R RadiusRCM Renovations Construction ManagerREF ReferenceREQ(‘D) Require(d)REV RevisionRND Round

SB StarbucksSC Solid CoreSF Square FeetSHT SheetSIM SimilarSPEC SpecificationSQ Square

TEMP TemporaryTYP Typical

UON Unless Otherwise Noted

VD Vendor DirectVERT VerticalVIF Verify in Field

PXXX-ES

XXXXX

North Arrow

Exterior Elevation

Interior Elevation

Section Callout

Detail Callout

Paint Tag

Design ID Tag

Door/Window Tag

Revision Cloud

Revision Tag

X' XX"

Dimension Line fromFinish Face to Finish Face

Datum Point

X'-XX" AFF

X

Above Finished FloorHeight Tag (imperial)

XXXX AFF Above Finished FloorHeight Tag (metric)

XXXXX

1. All work shall be performed in strict compliance with local, county, state, and federal codesand ordinances.

2. General Contractor shall verify the location of all utilities.

3. General Contractor to verify all dimensions, including clearances required by other trades,and notify Starbucks Development Manager of any discrepancies prior to proceeding with thework. All dimensions are to the face of the finished surface unless noted otherwise. Alldimensions to be taken from designated datum point. Do not scale drawings.

4. General Contractor shall patch and repair all existing walls, floors, ceilings, or othersurfaces identified to remain that may become damaged during the course of the work.

5. The General Contractor is responsible for obtaining permits for fire protection, plumbing,mechanical, and electrical systems prior to installation of such systems.

6. Responsibility for supply and delivery of materials and equipment is identified in thedrawing schedule sheets under the column labeled "Responsibility".

7. For the purpose of the documents, to “install”, shall mean to provide all fasteners,miscellaneous hardware, blocking, electrical connections, plumbing connections, and otheritems required for a complete and operation installation, unless otherwise noted.

8. All item substitutions must be approved by the Starbucks Design Manager.

9. Refer to item cutsheets for additional information.

JURISDICTION CLEMSON UNIVERSITY HARCOMBE UNIVERSITY CENTERPICKENS COUNTYCLEMSON, SC

SOUTH CAROLINA DEPARTMENT OF LABOR, LICENSING, AND REGULATIONSYNERGY BUSINESS PARK; KINGSTREE BUILDING110 CENTERVIEW DR.COLUMBIA, SC 29210803.896.4300

CODE CRITERIA AS SET FORTH IS APPLICABLE AS ADOPTED AND/OR AMENDED BY NOTED JURISDICTION

APPLICABLE CODES

BUILDING CODE INTERNATIONAL BUILDING CODE 2009EXISTING CODE INTERNATIONAL EXISTING BUILDING CODE 2009

MECHANICAL CODE INTERNATIONAL MECHANICAL CODE 2009ELECTRICAL CODE NATIONAL ELECTRIC CODE 2009PLUMBING CODE INTERNATIONAL PLUMBING CODE 2009

GAS CODE INTERNATIONAL GAS CODE 2009FIRE CODE INTERNATIONAL FIRE CODE 2009ENERGY CODE COMMERCIAL ENERGY CODE

LIFE SAFETY CODE NFPA 101 LIFE SAFETY CODE 2009

ACCESSIBILITY CODE ADA ACCESSIBILITY GUIDELINES 1994

Harcombe Univeristy Center

1 (Plaza Deck Above)

1975

II-A Renovations to existing

1-HR

No

22,269 sf

3,096 sf14 % Total plate renovation

A-2

3,096 sf / 15 = 206

CODE CRITERIA

SITE:

TOTAL FLOORS:

BUILT:

CONSTRUCTION TYPE:

FIRE RATINGS:

SPRINKLERS:

TOTAL SF:

SCOPE OF WORK:

OCCUPANCY TYPE:

OCCUPANCY LOAD:

STARBUCKSLOCATION

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:2

1:01

PM

G-001

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

General Information

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Project ContactsAbbreviation List Symbol Legend

Licensee General Notes

Applicable Codes

Scale: 1/16" = 1'-0"

Key Plan - Harcombe University Center

no. description date

Page 3: plantas starbucks

ADA KeyA. 30" x 48" clear for wheelchair access.

B. Barrier-free path of travel.

Scope of Work Summary1. Not Used.

2. Construct new wall(s) as indicated by hatch on Floor Plan.

3. Construct new soffits/ceilings as indicated on ReflectedCeiling Plan.

4. Install new flooring as indicated on Floor Finish Plan.

5. Install new casework items as indicated on Casework Plan.Casework installation by Starbucks.

6. Install new plumbing items as indicated on FF&E plan; RE:MEP.

7. Install new specialty equipment as indicated on FF&E plan;RE: MEP.

8. Install new auxiliary items as indicated on FF&E plan; RE:MEP.

9. Install new light fixtures as indicated on Reflected CeilingPlan. See Interior Elevations sheets for clarity.

10. Install new HVAC items as indicated on Reflected CeilingPlan.

11. Install new wall treatments as indicated on Wall Finish Plan.

12. Install new furniture as indicated on FF&E plan.

13. Install new graphics as indicated on Interior Elevation sheetsand Wall Finish Plan.

14. Patch, prime and paint walls, ceilings and/or soffits asindicated on Reflected Ceiling Plan and Interior Elevationsheets.

15. Install new door as indicated on Floor Plan.

16. New Storefront System as indicated on Floor Plan.

17. Install new signage as indicated on Exterior Elevations

18. Install new gate as indicated on Floor Plan.

19. Replace hardware at door as indicated on Door Schedule.

20. Install new vanity mirror centered over existing sink;"Reflection Mirror" by tiella

Men'sRestroom

Women'sRestroom Workroom

B B

B

BB

B

B

B

B

A

.7 5 8

3 4 9

10 11 14

3 4 9

11 12 13

10

14

AA

CafeSeating

AA

2

.5 6 7

BB

B

B

. .5 7

6

5

16

5 7

515

A

.5 7

.6 7 6

7 7 7

7

77 7

77 7

6

4 9

10 11 14

7 6

2 3

7

7

Bar

15

.5 6 7

16

OutdoorSeating

12 17

NIC NIC

2A-502

B

4 11

4 11 14

17

17

18

1919

20

20

3

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:2

1:36

PM

G-002

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

Scope of Work Plan

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 1/4" = 1'-0"1 Scope of Work Plan N 0 2' 4' 8'

Scale: 1/4" = 1'-0"

no. description date

Page 4: plantas starbucks

1

1

NIC NIC

1

2

3

4

4

5

6

7

7 7

7

8

99

99

8

8

8

8

8 8

5

5

3

11

1111

10 10 10

12

12

Demolition Plan Notes1. Demolish existing walls as indicated.

2. Remove door and frame and discard.

3. Replace hardware at door per door schedule.

4. Remove cased opening and discard.

5. Remove floor finish and discard. Prepare slab toreceive new concrete topping. RE: Specs

6. Remove equipment and salvage to owner.

7. Remove furniture and salvage to owner.

8. Remove existing gaming equipment and salvageto owner.

9. Remove existing television and mountinghardware; salvage to owner.

10. Chair rail at storefront to be removed.

11. Prepare door and frame for new finish, asscheduled.

12. Area to be trenched. RE: Elec and Plumbing

Existing Column to Remain

Existing Wall to Remain

Material to be Demolished

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

9:59

PM

D-100

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

Demolition Plan

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 1/4" = 1'-0"1 Demolition Plan - 1st Floor N 0 2' 4' 8'

Scale: 1/4" = 1'-0"

Wall Legend - Demo Plan

no. description date

Page 5: plantas starbucks

Armstrong is not licensed to provide professional architecture or engineering design services.

compliance with all Legal Requirements.advised to consult with a duly licensed architect or engineer in the particular locale of the installation to assure

the drawings for a particular installation or their fitness for a particular purpose.Armstrong does not warrant, and assumes no liability for the accuracy or completeness of

applicable for a particular installation.local building codes, laws, statutes, ordinances, rules and regulations (Legal Requirements) that may be

They are not a substitute for an architect's or engineer's plan and do not reflect the unique requirements ofThese drawings show typical conditions in which the Armstrong product depicted is installed.

The user isDATE:

DRAWN BY:

DWG. NO.

PROJECT NAME:

SCALE:

CHK BY:

PATH:

DESC.:

REV: DATE:

CEILING SYSTEMS * Phone: 877-ARMSTRONG

AXIOM-KNIFE EDGE PROFILE.

PROFILE08/08/08

MSS

.

4

1

NIC NIC

1 1 12

3

4

4 44

4

4

2

3

3

33

6

5

7' - 4" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0" 5' - 0"

3' -

0"5'

- 0"

73

Demolition RCP Notes1. Remove existing rafter and chicken wire ceiling and discard.

2. Remove metal ceiling plate and discard. Framing and sofits toremain.

3. Existing hard ceilings to remain, patch and repair as necessary.

4. Remove light fixtures and discard.

5. Remove existing equipment and salvage to owner.

6. Ceiling fan to be removed.

7. Hard ceiling to be removed to structure above by owner prior to startof work; framing and supports to remain in place.

Wire Ceiling and Supports to be Demolished

Hard Ceiling to Remain

Hard Ceiling to be removed by Ownerprior to start of work

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:2

0:31

PM

D-200

0816.01

Author

Checker

05-25-2012

Starbucks Coffee Company

Demolition Ceiling Plan

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 1/4" = 1'-0"1 Demolition Ceiling Plan - 1st Floor N

0 2' 4' 8'

Scale: 1/4" = 1'-0"

RCP Demo Legend

no. description date

Page 6: plantas starbucks

Floor Plan NotesA. General Contractor to verify all dimensions and notifyStarbucks Construction Manager of any discrepancies prior toconstruction. All dimensions to be taken from designateddatum point.

B. If existing exterior entrance threshold exceeds requiredAmerican’s with Disability Act (ADA) maximum allowable1/2" bevel or 1/4" step (total change of not more than 1/2"),remove and replace with accessible threshold. Raisedthresholds and floor level changes at accessible doorways tobe beveled with a slope no greater than 1:12.

C. General Contractor to provide fire treated wood studblocking, or equivalent to support any wall attachment and/orsignage.

D. All doors to provide 32” (900mm) minimum clear openingwhen opened to 90 degree position unless otherwise noted.

E. Verify all existing doors, hardware and frames meetStarbucks and/or code requirements.

F. Install 1/4" glass-mat water resistant backing board onbackbar wall per specification.

Sheet Notes1. Align both sides. Frame into existing wall.

2. New storefront to match existing storefront.

3. RE: X0055 / A-505

4. RE: X0021 / A-503

5. RE: X0024 / A-503

6. Tube steel wall support, RE: 5 / A-501

Existing Column

New Partial Height Wall

New Full Height Wall

Existing Wall

9' -

7 3/

4"

2' -

6 1/

2"

9' -

8"

14' - 1 1/2"

2' - 0 1/4"

7' -

0"6'

- 0"

7' -

0"2'

- 7

1/2"

CafeSeating

Workroom

Women'sRestroom

Men'sRestroom

1

4' -

7"16

' - 2

1/2

"

12' - 6 1/4" 1' - 7"

3' - 6" 18' - 2 1/2" 31' - 10"

2' - 0"

2' -

0"

9' -

7 3/

4"

9' -

4 3/

4"

13' - 7"

2' -

2 3/

4"2'

- 7

1/2"

2

2

4

5

Bar

1' -

7 1/

16"

12' -

8 3

/16"

6' - 4 3/16"

NIC NIC

A-5014

2

6

5

3

4

2 1

Existing Door to Remain;New removeable centermullion, new hinges, newclosers.

Existing Door to Remain

6

7

7

7

1

2

3

1

2

3

4

4

1

1

Glazing:T = Tempered

Frame:AL = Aluminum StorefrontHM4 = Hollow Metal No Rabbet

Construction:SC = Solid CoreWD = Wood

Door Legend:

Door Hardware Set No. 4 Workroom Door, @ BackbarCount Item Description Manufacturer Finish1 Easy Swing Hardware Eliason Door Packaged with Hardware Eliason Black Powder Coat

Door Hardware Set No. 5 Gate @ BackbarCount Item Description Manufacturer Finish1 SCP - Gate (hardware only) Easy-swing hinges & gate post Eliason Black Powder Coat

Type A

TT

Type B Type C

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

6:23

PM

A-112

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

Floor Plan

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Wall Legend - Floor Plan

Scale: 1/4" = 1'-0"1 Floor Plan N 0 2' 4' 8'

Scale: 1/4" = 1'-0"

Door Schedule

Design ID Count Description Width Height Finish Door TypeConstruction

TypeHardware

Group Frame Type Frame Material Responsibility CommentsGlazed Doors & Entrances

1 1 Aluminum - Double Storefront metal Frame 6' - 0" 7' - 11 1/2" Black A AL Existing Door to Remain; New removeablecenter mullion, new hinges, new closers.

2 1 Aluminum - Double Storefront metal Frame 5' - 11 1/2" 7' - 11 1/2" A AL Existing Door to Remain3 1 Aluminum - Double Storefront metal Frame 6' - 0" 7' - 11 1/2" A AL

Interior Doors4 1 Door - Single Impact Double Acting - 36in

915mm3' - 0" 7' - 2" WD0019 B SC 4 HM4 N/A GC

5 1 1" Thick Wood Gate - Single ImpactDouble Acting

3' - 0" 2' - 6" WD0019 C SC 5 N/A N/A GC Gate post system provided by Eliason. Customwood gate with planking finish per caseworkFinish Schedule. WD0019. Supplied byCasework Vendor

6 1 Door - Double Flush - 28in 710mm 2' - 4" 7' - 0" Paint Paint to match surrounding walls7 3 Door - Single Flush - 36in 915mm 3' - 0" 7' - 0" Paint Paint to match surrounding walls; 1" clear

undercut at restrooms

Door Type Legend

no. description date

Page 7: plantas starbucks

Penetration Plan NotesA. All stub-up dimensions are relative to finished wall locations(shown as outlines on this plan). Refer to Construction Plan forwall placement.

B. Floor Sink: Refer to cut sheets for component specificationsand cutout requirements.

C. Waste Line Penetrations: Refer to Plumbing Plans forindividual line specifications.

D. Stub-up Penetrations: Refer to Plumbing Plans for individualstub-up specifications.

E. Toilet Floor Penetration: Refer to cut sheets for stub-uplocation relative to finished wall.

F. Penetration to be located on centerline of wall or as requiredper conditions.

G. Trenching outline for guideline use only. General Contractorto coordinate with specific trades and site conditions todetermine actual layout.

All conduitstub upsto be withinthis boundary

Dimensiondatum point

CWF stub up

CW stub up

0' - 7"

0' -

3"

Eq.Eq

.

HW stub up

All conduitstub upsto be withinthis boundary

Dimension datum point

Eq.

3/4" LAN conduitto POS / safe

3/4" isolated groundpower conduit

3/4" LAN conduit tomanager's station3/4" isolated groundpower conduit

1' - 9"

0' -

3"

Eq. All conduitstub upsto be withinthis boundary

Dimension datum point

Eq.

3/4" power conduitto electrical panel

1/2" phone to managersdesk

1/2" data to managersdesk

0' -

3"

1' - 6"

Eq.

3/4" power tofoodcase

3/4" power future

1/2" security tomanagers desk

Floor sink set flush with top finish floor

Caulk Joint

Existing concrete floor

No-Hub connection

3" Tail Piece

Grind concrete floor to drain

Slope downward to drainSlope

8' - 10 3/4" 5' - 10 1/4" 1' - 8"

A-1134

A-1133

A-1132

A-1132

A-1135 A-113

5

A-1135

A-1135

A-1135

10294

10294

10294

1' -

2 1/

2"

5' -

7 3/

4"11

' - 7

1/2

"

CafeSeating

WorkroomWomen'sRestroom

Men'sRestroom

34' - 8 1/2"

32' - 10" 10' - 9 3/4"

7' -

11 1

/2"

4 11/16" 6 1/8"

1029410294

Bar

4 1/

4"

5"

NIC NIC

8' -

3 3/

4"

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

6:29

PM

A-113

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

Penetration Plan

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 1 1/2" = 1'-0"2 Stub-Up @ FrontBarScale: 1 1/2" = 1'-0"3 Stub-Up @ FrontBar

Scale: 1 1/2" = 1'-0"4 Stub-Up @ POS/SafeScale: 3" = 1'-0"5 Floor Sink Detail

Scale: 1/4" = 1'-0"1 Penetration Plan N 0 2' 4' 8'

Scale: 1/4" = 1'-0"

no. description date

Page 8: plantas starbucks

FF and E Plan NotesA. General Contractor to schedule with local refrigerationContractor to conduct initial food case start-up and testing. Forapproved Contractor, contact vendor.

B. The space is served by the municipal water and sewersystem unless otherwise noted.

C. All equipment and installation will meet National SanitationFoundation standards or equivalent.

D. Equipment units shall contain no exposed threads,embellishments or overhanging edges that serve as places foraccumulation of dust, dirt and debris.

E. Warming oven(s) shown for permitting purposes. Installationat store opening to be verified by Starbucks ConstructionRepresentative.

F. Each hand washing sink will have a single service towel andsoap dispenser, and all hand sinks to have a combination faucetor premixing faucet.

G. See sheet I-601 for schedules.

Sheet Notes1. See elevations for distribution of cup dispensers

2. Place fire extinguisher in workroom per fire inspector.

3 POS equipment specs & installation by licensee. Verifyequipment provided with licensee.

(8)(8)(6) 12303

X003312184

(6)(6)(6)

X0003(12)

X00101218412303 (2)

X00101218412303 (2)

X0008X0003 (4)

X00101218412303 (3)

(4)X0008X0003 X0003(10)

X0010

12303 (2)(2)(2)

(3)

X00101218412303

X0010121841230312184

X00101218412303

X0008X0003 (4)

11901

X0004 (3) (8)(8)(8)

X0001X0004

X0033 (8)(8)(8)

Workroom

CafeSeating

Women'sRestroom

Men'sRestroom

105971323810917 (2)

(2)

(2)

12694108551009110396

10153108741021511003

(4)(4)

(6)(6)

12618

10473

1034412508

1050510215

10527(2)

2

1

312023

11115

10797(2)(2)

(3)

X0006

X0005

X0002(2)

(2)

X0006(2)

X0002X0032

(2)

(3)

X00331218412303

(2)

10818 1081810818

12193X0011

X0011

1

11061(4)

1051312149(2)

1051312149(2)

1051312149(2)

1051312149(2)

1051312149(2)

1051312149(2)

1051312149(2)

X0009

X0009

1240712480

1058110597

1097710947

10501

1010210475

108551009110396

10495

10305

1054910152

1072410314

1091710452

10439 (2)11055 (2)107881075711737

10452

(2)

10967 11083

(2)

108551009110396

(2)

1022211070

1071910447

104161046210462

10416

10995

10698

10922

X00331218412303

1007610005

(4)

1216012149(2)

X00101218412303 (2)

NIC NIC

10838

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

6:52

PM

A-114

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

FF and E Plan

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 1/4" = 1'-0"1 Furniture, Fixtures and Equipment Plan N 0 2' 4' 8'

Scale: 1/4" = 1'-0"

no. description date

Page 9: plantas starbucks

Casework Plan NotesA. General Contractor to notify Starbucks ConstructionManager immediately if a discrepancy exists betweencasework shop drawings, site dimensions, casework plan oractual casework fixtures. All dimensions to be taken fromdesignated datum point.

B. Starbucks Construction Manager to coordinate andschedule casework delivery date. General Contractor toconfirm casework delivery date with casework manufacturer 4weeks and 1 week prior to scheduled date of delivery.

C. Starbucks contracts directly with casework vendor tosupply casework listed in casework schedule, unlessotherwise noted.

D. Refer to casework installation manual provided bycasework vendor for complete installation instructions.

E. All casework base units shall be set on 1/4" (6mm) non-absorbent plastic shims provided by casework vendor.

F. See Wall Finish Plan for location, tagging, and finishschedules of applied wall treatments.

G. Install oven stainless steel countertop and base cabinet with1/2" (10mm) gap between adjacent countertops.

H. See Reflected Ceiling Plan for casework soffit locations.

J. See Schedule sheets for schedules

Sheet Notes1. Do not caulk trash rings to countertops.

Indicates Stainless Steel

Indicates Chair RailDesign ID: X0025

Indicates Wall PlankingDesign ID: X0027

Indicates Wall PlankingDesign ID: X0028

A

B

C

A-1152

12802

11155

X0029

(2)

11900

11915

11930

11971

11971

11972

11973

11993

1200712082

1209112100 (3)

X0017

1191212103

X0018

12128

X0023

01-01

ADD

MODIFIED

BRW 01-02

ESP 10-02

X0021(2)

(4)

X0022

CafeSeating

WorkroomWomen'sRestroom

Men'sRestroom

MO

DIF

IED

CBS

07-

01 X0030

12474

X0016

A

AA

A

A

AA

A

9' -

3 3/

4"

C C

B B

X0045 (3)

X0046

1193311942 11945

1209612080X0048

X00491208012098120141197112096

X0056

MODIFIED

POS 18-01

X0024

MODIFIED

BRW 07-02

3' -

0 5/

8"3'

- 0"

3' -

4"

X0047

MOD.

SCL 03-01 X0044X0053X0020

X0055

X0051

X0043X0054

X0052

13287

11994X0050

12775

WRM 02-01

(2)

10' - 0"

10"

12127

X0031

11957

1

1

NIC

A

NICA-504

7Sim

1197711977 11977 11977

11902

11977 11977

1284512845

12816 12816

(Below)

11959

0' - 3 1/4"

12845

1197712816 12816

11977 11977 X0034

3 1/4"12' - 6 3/8"

12845

11956

12845

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

6:59

PM

A-115

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

Casework Plan

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Casework Plan Legend

Scale: 1/4" = 1'-0"1 Casework Plan

N 0 2' 4' 8'

Scale: 1/4" = 1'-0"

Scale: 1/4" = 1'-0"2 Upper Casework Plan

no. description date

Page 10: plantas starbucks

Reflected Ceiling Plan NotesA. If required by local code, General Contractor to provide semi-recessed sprinkler heads with polished chrome escutcheonscentered in Acoustical Ceiling Tile. If pendant heads arerequired in gypsum soffit over frontbar, conceal supply pipingwithin soffit. General Contractor to submit sprinkler layout toStarbucks' Construction Manager for approval prior toinstallation.

B. General Contractor to provide and locate sprinklers per localcodes. Contact Starbucks Construction Manager if design intentis affected.

C. Where acoustical ceiling meets wall, provide angle wallmolding for reveal. Match ceiling grid color when applicable.

D. Leave (10) additional retail ceiling tiles, to match retail ceilingpaint color, above the workroom ceiling at manager's desk forfuture use.

E. Provide grommet at all ceiling penetrations for fixtures orsupports.

F. Heating, Ventilating, and Air Conditioning (HVAC) shown fordesign intent only. Contact project manager if changed.

G. Diffusers and returns at backbar in Acoustical Ceiling Tile tobe centered in tile, painted to match adjacent finishes, typical.

H. Paint all HVAC ducts, HVAC diffusers, recessed speakersand light trim rings the same color as ceiling or soffit. Typicalthroughout retail portion of store.

I. Paint substitutions are not allowed. Use Starbucks' nationalaccount "color code" when ordering paints. See sheet I-602 forschedules.

J. Existing and new structure, ceiling, duct, conduit, piping, etc.to be painted out black in all locations visible to below. Anyequipment which may be affected by paint to be coordinatedwith architect and MEP and protected as necessary.

Sheet Notes1. Align

2. Not Used.

3. Paint ceiling prior to wood planking installation.

4. GC to paint recessed trim to match adjacent surfaces.

5. 2' x 2' Access panel in drywall. Coordinate location withMEP prior to fabrication.

6. 2' x 4' Access panel. Coordinate location with MEP anddetails with Architect prior to fabrication.

33' - 7 1/2"

2' -

3"

4' - 0"4' - 0" 4' - 0"

4' -

0"2'

- 8"

2' - 9 3/4" 4' - 0" 4' - 0" 4' - 0" 4' - 0" 4' - 0"4' - 0"

4' - 0"

2' - 8 1/2"

6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0" 6' - 0"

5' -

0"5'

- 0"

5' -

0"6'

- 0"

6' -

0"

6' -

0"6'

- 0"

5' -

0"

19' -

11

3/4"

2' -

3"2'

- 3"

2' -

3"

2' - 0 1/4" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0"

6' -

6"

3' -

4 1/

4"

9' -

7 3/

4"

1293412956

(4)(16)

11154 (8)

1324211458 (9)

(9)

1324411533 (3)

(3)

1324411533

(3)(3)

1324411533

(4)(4)

1324411533

(4)(4)

1324411533

(13)(13)

1324411533

(13)(13)

1324411533(13)

(13)

(4)(3)

(12)(12)

X0012(3)1324411533

(9)(9)

1324411533

(6)(6)

1324411533

(3)(3)

2' -

6"

5' - 0" 23' - 7 1/2" 5' - 0"

2' -

6"

2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0" 2' - 0"

CafeSeating

Workroom

Women'sRestroom

Men'sRestroom

8'-0" AFF

8'-0" AFF

8'-0" AFF

P551-SG

P546-SG

8'-3" AFF

8'-0" AFF

8'-7" AFF

13257 (9)

114581324213257 (12)

1' - 4"

EQEQ

12871 (3)

EQ EQ

132441153312871

(2)(2)(2)

12871

12871

(3)

(3)

12871

12871

12871

12871

12871(13)

(13)

(13)

(4)

(4)

12871(9)

2' - 0" 2' - 0" EQEQ

(2)

13' - 4"

3' -

6"16

' - 9

"

4' - 0" 9' - 5 3/4"

(2)

12871(6)

1

1

GWB Ceiling

GWB Ceiling

8'-0" AFF

GWB Ceilingw/ Suspended Planking

P552-ES

8'-0" AFF

GWB Ceilingw/ Suspended Planking

P552-ES

GWB Ceiling

GWB Ceiling

GWB Ceiling

12906(16)

X0014 X0014(2) (3)

12893 (16)

8'-0" AFF

Suspended PlywoodPanels

13181

X0014

X0013 X0013X0013EQEQ

4' - 0" 8' - 0" 20' - 0" 8' - 0" 4' - 0" 8' - 0" 11' - 11"

1' - 10 13/16"

3' - 10" TYP.

7' -

0"

2' -

5 9/

16"

Bar

13' -

6"

4' -

0"

2' - 7 15/16"

X0057

X0058

X0057X0059

(3)

X0027X0027

4

4 4

3

3

X0060 (19)

10017

10017

10017

10017

10017

P551-ES

P551-ES

P551-ES

NIC NIC

13181

2A-502

1A-502

3

A-502

Sim

8'-6" AFF

GWB CeilingP551-ES

6

6 6

5

5

5

Existing hard ceiling to remain;patch with GWB to match existing after

completion of mech and elec work

4A-502

Exist. GWB CeilingP551-ES

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

7:13

PM

A-116

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

Reflected Ceiling Plan

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 1/4" = 1'-0"1 Reflected Ceiling Plan N 0 2' 4' 8'

Scale: 1/4" = 1'-0"

no. description date

Page 11: plantas starbucks

Floor Finish Plan NotesA. Starbucks to supply retail floor tile and tile base. GeneralContractor to install. General Contractor to supply workroom tileand base and install. General Contractor to supply and installmortar, adhesive, and grout. General Contractor to inspect alltiles and reject damaged or substandard tiles prior toinstallation.

B. All tile and slate to be installed per Tile Council of Americastandards.

C. All flooring and base material to be installed according toStarbucks specifications.

D. Cabinet bases to be set after tile installation.

E. Align tile transitions on whole tiles as shown.

F. For carpet installation, refer to manufacturers' installationinstructions.

Sheet Notes1. Not Used.

2. Floor sink/floor drain location.

3. GC to infill score cuts in concrete with grout to matchconcrete.

Concrete Floor8'x8' score cut pattern

Tile Base - Black - 6x12Design ID: 11403A

Walk-Off MatDesign ID: 11158

Tile Base - Black - Cut to 6x2 per specsMatch Design ID: 11403B

CafeSeating

WorkroomWomen'sRestroom

Men'sRestroom

Tile - Base - Black -6x12in - 11403

Concrete Stain - DarkBrown

Concrete Stain - DarkBrown

A

AA

A

A

A A

A

B

AA

A

AA

A

A

A

A

A

A

A

A

A

A

A

A

A

B B B

A

2 2

22

2

Tile - Base - Black -6x12in - 11403

Tile - Base - Black -6x12in - 11403

Tile - Base - Black -6x12in - 11403

Concrete Stain - DarkBrown

Tile - Base - Black -6x12in - 11403

Concrete Stain - DarkBrown

6' - 2"

11158Walk off Mat

AA

Bar

B

A

A

AA

A

11289

11289

11289

3

A-501

1

A-501

2

A-504

2

A-501

A

NIC NIC

BB

A

BB

AA

B

A

AA

A

A

A

A

A

A

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

7:40

PM

A-117

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

Floor Finish Plan

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Floor Legend

Scale: 1/4" = 1'-0"1 Floor Finish Plan N 0 2' 4' 8'

Scale: 1/4" = 1'-0"

no. description date

Page 12: plantas starbucks

Wall Finish Plan NotesA. Workroom to be finished per local code requirements.

B. Install clear corner guards as indicated. Mount at 6”(150mm) AFF. Back-paint with corresponding wall color.Adhere with clear silicone adhesive and #6 stainless steel ovalhead screws 3” (75mm) from ends, 12” (305mm) on center.Offset screws on either side by 1/2" (10mm) vertically. Cutcorner guards to fit below chair rail at applicable locations. Donot install corner guards above chair rail.

C. Install metal corner guards as indicated. Mount at 6”(150mm) AFF. Affix with #6 stainless steel oval head screws 3”(75mm) from ends, 12” (305mm) on center offset screws oneither side by 1/2" (10mm) vertically. To be installed in back ofhouse only.

D. Change of paint color allowed at inside corners only.

E. Refer to Interior Elevations for graphics locations.

F. Refer to Casework Finish Schedule for additional information

G. General Contractor to provide and install workroom wallfinishes.

Indicates full height backbar wall tileDesign ID: 12320

Indicates full height FRPDesign ID: 11428

A

B

Indicates Leather WainscotDesign ID: X0063C

Indicates Leather WainscotDesign ID: X0064D

Full Height Wall TileDesign ID: T00001E

A-201

1

A-211

5

A-211

1

3

2

A-211

7

A-212

3

6

A

A

AA A

B

B

B

B

CafeSeating

Workroom

Women'sRestroom

Men'sRestroom

4 5

4

A-211

8

A-212 2

A-211 8Sim

A

A-2012

Bar

CC

C

CC

C

C

C

C

C

C

C

D

NIC

C

NIC

E

E

E

E

E

E

E

E

E

E

C

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

8:01

PM

A-119

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

Wall Finish Plan

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Wall Treatment Key

Scale: 1/4" = 1'-0"1 Wall Finish Plan N 0 2' 4' 8'

Scale: 1/4" = 1'-0"

no. description date

Page 13: plantas starbucks

Exterior Elevation NotesA. General Contractor to coordinate and schedule signageinstallation with the Signage Contractor providing a minimumscheduling notice of 4 weeks and shall confirm installationschedule with Signage Contractor 1 week prior to scheduleddate of installation. Starbucks Construction Manager toprovide General Contractor with Signage Contractor contactinformation.

B. General Contractor shall coordinate with ElectricalContractor to furnish and install electrical circuits including allconduit, wire, connections, and breaker at panel boardnecessary to serve Signage.

C. General Contractor to provide fire treated wood blocking, orequivalent to support Signage.

D. Signage Contractor shall verify size and location of any andall allowable monument or pole signage with landlord andprovide shop drawing(s) prior to fabrication to StarbucksDesigner for approval.

E. Signage Contractor to install signage in compliance withlocal codes ad obtain permit and landlord approval.

F. Signage Contractor to supply shop drawings to StarbucksConstruction Manager and to the General Contractor asneeded. General Contractor to notify Starbucks ConstructionManager immediately if shop drawings or installation is inconflict with Starbucks architectural drawings.

G. General Contractor to clean, patch and repair existingexterior as required.

H. See Schedule sheets for schedules

Sheet Notes1. Provide 3" high, 3/4" stroke width, acrylic store addresslettering in approved contrasting color, on or above storefrontdoor or in location approved by local AHJ standards.

1

4' -

10"

13181

STUDENT UNIONDISPLAY BOARD

13181 4' -

10"

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

8:06

PM

A-201

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

Exterior Elevations

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 1/4" = 1'-0"1 Exterior Elevation @ Storefront

Scale: 1/4" = 1'-0"2 Elevation @ Interior Storefront

no. description date

Page 14: plantas starbucks

Interior Elevation Notes

Sheet Notes1. Attach menu hinge to top of cabinet to allow access tocabinet shelves behind, typical.

2. Apply FRP to all sides of chase interior behind cubbie.

3. Cup dispener(s) mounting order from left to right:- Grande Venti- Grande Venti- Tall Hot- Short Hot

4. Backbar wall tile runs behind warming station.

5. Paint wall prior to installing wood planking and/orplywood panels.

6. GC to add outlets to front "kick plate" centered at eachtable.

A. Change of paint color allowed at inside corners only.

B. Refer to manufacturers' instructions shipped with artworkfor installation instructions and spacing.

C. Install wall cabinets before backbar wall tile. Run backbarwall tile to underside of wall cabinets, not behind cabinets.

D. Paint substitutions are not allowed. Use Starbucks'national account "color code" when ordering paints.

E. Paint finishes shall be applied as follows, unless otherwisenoted;

- All wood and metal surfaces shall be paintedSemigloss, or equal.- All accent and trim paint to be Semigloss, or equal.- All wall and ceiling paints to be Eggshell, or equal.

F. See Schedule sheets for schedules

CBS 07-01

MODIFIED

12860 12976

3

11

4

BRW 05-02

MODIFIED

Tile - Mottled DarkBrown - 2x8in - 12320

Tile - Base - Black -6x12in - 11403

Tile - Base - Black -6x12in - 11403

Tile - Mottled DarkBrown - 2x8in - 12320

01-01

ADD

BRW 05-02

MODIFIEDWRM 02-01

P552-ES

X0064

3' -

4 1/

2"

X0025

Tile - Mottled DarkBrown - 2x8in - 12320 ?

Open

Tile - Base - Black -6x12in - 11403

P546-SG

NEW FOODCASE MODIFIED POS 18-01 ESP 10-02

Open

Tile - Base - Black -6x12in - 11403

Open

SCL 03-01

MOD

P546-SG

5' -

3"

NEW FOODCASEMODIFIED POS 18-01ESP 10-02

OpenOpen

3

SCL 03-01

MOD

Wood Planking - 1x6 -10'-0" Bd cut to fit

9' - 7 3/4"

P552-ES

X0027

5

Open

Tile - Base - Black -6x12in - 11403

Tile - Base - Black -6x12in - 11403

P546-SG

X0064

SW6272

EQEQEQEQ X0038 X0039 X0040 X0041

4' - 6" 4' - 6" 4' - 6" 4' - 6"

3' -

6"

3' -

6"

3' -

6"

3' -

6"

6' -

0"

6

4A-502

P546-SG

Tile - Base - Black -6x12in - 11403

New Gate

P552-ES

Tile - Base - Black -6x12in - 11403

X0025

X0063

3' -

0"

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

8:24

PM

A-211

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

Interior Elevations

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 3/8" = 1'-0"1 Elevation @ BackbarScale: 3/8" = 1'-0"2 Elevation @ Sidebar

Scale: 3/8" = 1'-0"5 Elevation @ Frontbar (Customer Side)

Scale: 3/8" = 1'-0"3 Elevation @ Frontbar (Partner Side)

Scale: 3/8" = 1'-0"6 Elevation @ Side Nook

Scale: 3/8" = 1'-0"7 Elevation @ Banquette Seating

Scale: 3/8" = 1'-0"4 Elevation @ Side Bar

Scale: 3/8" = 1'-0"8 Elevation @ Back Hall

no. description date

Page 15: plantas starbucks

Interior Elevation Notes

Sheet Notes1. Not Used.

2. Not Used.

3. Not Used.

4. Not Used.

5. Paint wall/ceiling prior to installing wood planking.

6. GC to add outlets to front "kick plate" centered at eachtable

A. Change of paint color allowed at inside corners only.

B. Refer to manufacturers' instructions shipped with artworkfor installation instructions and spacing.

C. Install wall cabinets before backbar wall tile. Run backbarwall tile to underside of wall cabinets, not behind cabinets.

D. Paint substitutions are not allowed. Use Starbucks'national account "color code" when ordering paints.

E. Paint finishes shall be applied as follows, unless otherwisenoted;

- All wood and metal surfaces shall be paintedSemigloss, or equal.- All accent and trim paint to be Semigloss, or equal.- All wall and ceiling paints to be Eggshell, or equal.

F. See Schedule sheets for schedules

SW6272

X0036 X0035 X0037

4' -

0"

3' - 0" 6' - 0" 3' - 0"

4' -

0"

4' -

0"

5' -

8" 8' -

0"

6

EQ EQ EQ

P552-ES

Wood Planking - 1x6 -10'-0" Bd cut to fit

P552-ES5

X0025

13181

X0063 X0063

4' -

10"

Tile - Base - Black -6x12in - 11403

Tile - Base - Black -6x12in - 11403

Wood Planking - 1x6 -10'-0" Bd cut to fit

X0027

X0025

X0025

3' -

0"

P552-ES 5

X0042

13' - 6"

6

X0063

X0063

7' -

6"

6' -

8"

Wood Planking - 1x6 -10'-0" Bd cut to fit

X0027

P552-ES5

P546-SG

OPEN

Tile - Base - Black -6x12in - 11403

3' -

0 3/

4"

6

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

8:33

PM

A-212

0816.01

DK

JP

05-25-2012

Starbucks Coffee Company

Interior Elevations

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 3/8" = 1'-0"3 Elevation @ Banquette Rear Wall

Scale: 3/8" = 1'-0"2 Elevation @ Storefront

Scale: 3/8" = 1'-0"4 Elevation @ Back Wall

Scale: 3/8" = 1'-0"5 Elevation @ Bar Entry

no. description date

Page 16: plantas starbucks

Fiberglass reinforced plastic

Finish panelDie wall

Bullnose sanitary integralcoved tile base

Existing concrete slab

New 3/8" concrete topping

New integral bullnose sanitary3/8" cove tile base

Existing concrete slab

Existing wallboard

5 1/

2"

New tile backer board

New 3/8" concrete topping

Backer rod and sealant,typ at all floor joints

Existing stud framing

Storefront door and threshold

New or existingwalk off mat

Waterproof membrane,(only if on wood subfloor)

3/8" (10mm) metal edge orsimilar for design intent.Slide metal leg under mat.Clip leg edge as needed to fita curve.

Rubber Reducertransition strip

concrete

Anchor stud to existing concrete column

Backer rod and sealant,both sides, typ.6" metal stud

Blocking as required forstorefrontDrywall corner bead,both sides, typ.

New storefront systemwith high sidelight baseto match existing, perspecs

Leave 1" gap at existing,exterior glazing

2' - 0"

5' -

0" .

5x7x3/8 STEEL ANGLE3/4" DIA. EXPANSION

ANCHOR WITH WASHER AT6" O.C.; EPOXY SET INTO

EXISTING FLOOR SLAB

HSS 5x5x3/8 STEEL TUBESUPPORT

SECURE WALL STUDFRAMING WITH 1/2" THRU

BOLT @ 12" O.C.

CONTINUOUS WELD

4x4x1/4 STEEL ANGLEBRACE AT 45 DEGREES;

BOLT BOTH SIDES

CONTINUOUS WELD

New integral bullnose sanitarycove tile base as scheduled

Existing concrete slab

New tile backer boardmechanically fastened toexisting CMU wall

New 3/8" concrete topping

Backer rod and sealant,typ at all floor joints

Existing CMU wall

New wall tile as scheduled

New integral bullnose sanitary3/8" cove tile base

Existing concrete slab

5/8" Gypsum wallboard with finish asscheduled, both sides; 5/8" tilebacker board at wall tile; RE: 1/A-119

5 1/

2"

Tile backer board 5 1/2" TYP;Full Height @ Bar RE: 1/A-119

New 3/8" concrete topping

Backer rod and sealant,typ at all floor joints

6" metal stud framing

Continuous metal runneranchored to floor

HSS 5X5X3/8 steel tube supportRE: 5/A-501

Metal Stud Track; Fasten @2'0" O.C. MAX.

Existing ceiling to remain;Frame to deck above wherethere is no existing ceiling

Full height FRP as required; RE:1/A-119

New integral bullnose sanitary3/8" cove tile base

Existing concrete slab

5/8" Gypsum wallboard withfinish as scheduled, bothsides; FRP one side @Workroom RE: 1/A-119

5 1/

2"

5/8" Tile backer board

New 3/8" concrete topping

Backer rod and sealant,typ at all floor joints

3 5/8" metal stud framing

Continuous metal runneranchored to floor

Metal Stud Track; Fasten @2'0" O.C. MAX.

Existing ceiling to remain;Frame to deck above wherethere is no existing ceiling

New integral bullnose sanitary3/8" cove tile base

Existing concrete slab

Full height tile backerboard, one side

New 3/8" concrete topping

Backer rod and sealant,typ at all floor joints

1 3/4" metal stud framing

Continuous metal runneranchored to floor

Metal Stud Track; Fasten @2'0" O.C. MAX.

Existing ceiling to remain;Frame to deck above wherethere is no existing ceiling

Existing concrete slab

New 3/8" concrete topping

6" metal stud framing

Storefront system anchoredto slab. RE: Specs

Double wood 2x6 stud header

Storefront sill mullion.RE: Specs

Storefront system glazing

Storefront top mullionRE: Specs

5/8" Gypsum wallboard with finishas scheduled, both sides

Metal Stud Track; Fasten @2'0" O.C. MAX.

Anchor to concrete beam;expansion anchor set in epoxy

existing concrete beam

Metal Stud Track; Fasten @2'0" O.C. MAX.

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

8:39

PM

A-501

0816.01

Author

Checker

05-25-2012

Starbucks Coffee Company

Partition Types and WallDetails

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 3" = 1'-0"1 Integral Tile Base @Die WallScale: 3" = 1'-0"2 Integral Tile Base @ Existing Interior Wall

Scale: 3" = 1'-0"3 Transition - Concrete to Walk off Mat

Scale: 1 1/2" = 1'-0"4 Exterior/Interior Storefront Interface

Scale: 1" = 1'-0"5 STEEL TUBE SUPPORT - AXONScale: 3" = 1'-0"6 Integral Tile Base @ Existing CMU Wall

Scale: 3" = 1'-0"7 Partition - Type 1Scale: 3" = 1'-0"8 Partition - Type2

Scale: 3" = 1'-0"9 Partition - Type 3Scale: 3" = 1'-0"10 Partition Type - 4

no. description date

Page 17: plantas starbucks

Wall/Ceiling Plank Lighting Section

0' - 0 1/2" 0' - 0 1/2"

0' - 6" 0' - 6"

Cleat centered on Wood Plank

Continuous LED lighting

V.I.F.

9' - 8"

0' - 6" 3' - 0" 3' - 0" 2' - 11"0' - 1 1/2"

0' - 1 1/4"

9' - 6"

0' - 0 3/4"

Ceiling Planks Section

0' -

6"0'

- 6"

Ceiling Planks Plan - Typical 6" spacing

Continuous BlockingTypical at cleat location

French Cleatspaced every 3'-0"

Wood trim glued and pin nailedto anchor blocking

Allow spacing for LED lighting on both sides of cleatrunning entire length of wood planking

Attach anchor blocking to soffit framing

Align wood trim w/ face of soffit

1x6 Wood Planks, finish per casework finish schedule

1x6 Wood Planks, finish per casework finish schedule

BOTTOM OF PLANK8'-0"

1' - 0" EQ EQ 1' - 0"

3' - 10"

1' -

0"EQ

EQ1'

- 0"

EQ EQ

Plan

Section

Custom Suspended Plywood PanelingTypical spacing: 4'-0" O.C.

Unistrut P1000 w/ 5/8" threaded rodsupport to structure above

Carriage bolt thru unistrut

7' -

0"

BOTTOM OF PANEL8'-0" A.F.F.

3/4" Thick Lamlite Panelwith Walnut veneer

Existing mechanical ductbeyond

Box beam supports at 16" O.C.attached to thread rod

Suspended light fixtureRE: 3/A-506

5 13/16" Extruded Aluminumtrim panel

5/8" Gyp board ceiling

MIN

6"

4"1'

- 0"

6' - 8" AFF

8' - 0" AFF

Existing mechanical duct

Existing hard ceiling to remain

Box beam framing to span existing ceiling

Thread rod from box beam toexisting structural deck above

3 1/2" metal stud framingsystem with studs at 16" O.C.in each direction; frame toavoid fixtures; box beams asnecessary to span belowexisting hard ceiling to remain

5/8" All thread rod with steelanchor plate at each box beam

Existing structural slabExisting mechanical duct beyond

Existing hard ceiling and framing

5/8" Gyp board6" Metal wall stud5/8" Gyp board ceiling

Gyp ceiling @ bar bulkhead

Recessed can light fixtures

Gyp board; maintain 1'-0" clear tostructural deck above

3 1/2" metal stud framing systemwith studs at 16" O.C. in each

direction; frame to avoid fixtures; boxbeams as necessary to span below

existing hard ceiling to remain

2' -

7"

Mounted track lighting

8' - 0" AFF8' - 3" AFF

1' -

0"

8' - 7" AFF

Gyp ceiling to match existinghard ceiling depth

New mechanical fan; support fromstructural deck above

Stud Kickers at 32" O.C.

Frame stud beams to existingCMU wall

Gyp board ceiling

4" steel box beams at 16" O.C.;continuous studs, full length

11' - 5 1/2"

5/8" all-thread rod to structureabove; secure to beams withsteel anchor plate

Existing duct to remain

Section of existing ceilingremoved prior to start of work;See sheet D-200

Stud framing to structureabove at 16" O.C.

Wood plank ceiling treatment;See 3/ A-502

4" steel studs at 16" O.C.

Existing ceiling to remain

8' - 2 1/4" AFF8' - 0" AFF

1' -

0"

Continue gyp 1'-0" at wall

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

8:46

PM

A-502

0816.01

Author

Checker

05-25-2012

Starbucks Coffee Company

Ceiling Details

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 3" = 1'-0"

Ceiling Plank Lighting DetailScale: 3/4" = 1'-0"3 X0027 10' Nook Ceiling Planking Detail

Scale: 3/4" = 1'-0"

X0060 Custom Plywood Ceiling Panels

Scale: 1 1/2" = 1'-0"2 Suspended Ceiling Panel Detail

Scale: 1 1/2" = 1'-0"1 Ceiling Bulkhead @ Bar Detail

4 5

no. description date

Scale: 1 1/2" = 1'-0"4 Ceiling Framing @ LED Plank

Page 18: plantas starbucks

2' - 7"

2' - 8 1/2"

0' -

4"1'

- 1

1/2"

1' -

9 1/

2"

3' -

3"

V.I.F.

8' - 4 3/4"

2' -

8 1/

2"

V.I.F

.

0' -

9 1/

2"

PLAN

SIDE ELEVATION

V.I.F.

4' - 7" 0' - 3 1/2" 1' - 7 1/4"

Custom U-Shape Settee based on Design ID 12844

GC to add outlets to front "kick plate"centered at each table

Corian Top CapSee I-504/7

1' - 7 1/2" 0' - 3 1/2"

V.I.F.

3' - 2"V.I.F.

5' - 1"

1' -

7 1/

2"

0' -

3 1/

2"

V.I.F

.

0' -

9 1/

2"

0' - 1 1/2"1' - 7" 0' - 2 1/2"

1' - 11"

V.I.F.

0' - 9 1/2"

V.I.F.

2' - 8 1/2"

1' -

5 1/

2"1'

- 9

1/2"

PLAN

LEFT ELEVATION

Custom L-Shape Settee based on Design ID 12844

GC to add outlets to front "kick plate"centered at each table

Corian Top CapSee I-504/8

PLAN

FRONT ELEVATION

Custom Banquette based on Design ID 12844

0' -

6"1'

- 0"

1' -

6"

0' - 7" 1' - 8 1/4"

V.I.F.

13' - 10" 1' - 8 1/4" 0' - 7"

V.I.F

.

9' -

8"

V.I.F

.

8' -

4"

GC to add outlets to front of "kick plate"of Banquette centered at each table

13' - 8"

0' -

8"1'

- 6"

1' -

6"

3' -

5"

0' - 5" 1' - 8" 0' - 7"0' - 7"

Custom Bar-Height Banquette based on Design ID 128441' - 0"

UpholsteredBack andSeat

8x8 Steel Platesecured to floorw/(4) 3/8" Dia. HiltiExpansion anchors.

GC to add outlets tofront "kick plate"centered at each table

CaseworkManufacturer to buildstep for banquette tosit on. Wood to matchbanquette.

0' -

0 1/

2"0'

- 1

3/4"

3' -

2"

0' - 1 1/2"

Metal base finish MT0011

0' -

8"

0' - 8"

0' - 0 3/4"

0' -

0 3/

4"

2" Dia. Steel Pipe

0' - 3 1/4"

Finish Panel at side

Custom Upper Cubby end piecebased on Design ID 11959

11' - 0"

3' -

6"2'

- 5"

0' -

6"2'

- 6"

0' -

6"

0' - 6" 10' - 0" 0' - 6"

4" x 4" Tube Steel Column, Typ. Solid Reclaimed Walnut top - Live Edge

1" x 3" steel angle apron, typ.

0' -

2"2'

- 3"

4" x 4" tube steel column, typ.

Wood top, solid reclaimed Walnut top - Live Edge

Custom Community Table Plan

Custom Community Table Elevation

0' - 6" 10' - 0" 0' - 6"

11' - 0"

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

8:52

PM

A-503

0816.01

Author

Checker

05-25-2012

Starbucks Coffee Company

Custom Seating Details

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 3/4" = 1'-0"

X0021 Custom U-Shape SetteeScale: 3/4" = 1'-0"

X0024 Custom L-Shape Settee

Scale: 3/4" = 1'-0"

X0022 Custom Banquette

Scale: 3/4" = 1'-0"

X0023 Custom High Banquette

6

Scale: 3/4" = 1'-0"

X0001 Custom Bar Height Table BaseScale: 3/4" = 1'-0"

X0034 Upper Cubby End Piece

Scale: 3/4" = 1'-0"

X0003 Custom Community Table

12

3

45

7

no. description date

Page 19: plantas starbucks

5' -

0"5'

- 0"

10' -

0"

Custom POS Counter to based on Design ID 12788Dimensions for modified items only

Corian counter tomatch profile standardcorian counter tops

Custom POS cabinet based on Design ID 12086Dimensions for modified items only

Plan

Elevation

V.I.F.1 1/2" Filler

3' - 7 1/2"

3' - 9"

Add third drawer to matchand extend shelving

3' - 9"

Custom POS cabinet based on Design ID 11990Dimensions for modified items only

Plan

Elevation Add third drawer to matchand extend shelving

3' - 7 1/2" V.I.F.1 1/2" Filler

3' - 9"

3' - 9"

Custom POS front Panel based on Design ID 11951Dimensions for modified items only

Plan

3' - 9"

10"

10' - 0"

Custom Queue Top cap based on Design ID 12758Dimensions of modified items onlyLive edge - 2 sides - see casework finish schedule

V.I.F

.

4' -

7"

1' - 7"

Short Wall Cap Plan

Custom Wall Top Cap based on Design ID 12758Dimensions for modified items onlySee casework finish schedule

V.I.F

.

6' -

4 1/

4"

1' - 7"

Long Wall Cap Plan

Custom Wall Top Cap based on Design ID 12758Dimensions for modified items onlySee casework finish schedule

1' -

5 5/

16"

1' -

7 1/

4"5"

2' -

1"5"

1' -

7 1/

4"1'

- 7

1/4"

4"

10' -

0"

Custom POS Toe KickBased on Design ID 11916Dimensions for modified items only

Customer side of casework

Adjustable stainless steel leg

Clip-on wood base panel.Attach to stainless steel legsat customer side of cabinetonly.

Wall Planks Plan

0' -

6"0'

- 6"

Wall Planks Section - Typical 6" Vertical Spacting

1x6 Wood Planks, finish per casework finish schedule Continuous LED Lighting

French Cleat at each board

4' - 0" 1' - 0" 4' - 0"

French cleats to attach planks to wall

LED lighting on underside of each french cleat,Wall/Ceiling Plank Lighting Section

0' - 0 1/2" 0' - 0 1/2"

0' - 6" 0' - 6"

Cleat centered on Wood Plank

Continuous LED lighting

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

9:05

PM

A-504

0816.01

Author

Checker

05-25-2012

Starbucks Coffee Company

Casework Details

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 3/4" = 1'-0"

X0052 Custom POS CountertopScale: 3/4" = 1'-0"

X0050 Custom POS CabinetScale: 3/4" = 1'-0"

X0051 Custom POS Cabinet

Scale: 3/4" = 1'-0"

X0054 Custom POS Panel

Scale: 3/4" = 1'-0"

X0016 Queue Top CapScale: 3/4" = 1'-0"

X0046 Partial Wall Top CapScale: 3/4" = 1'-0"

X0047 Partial Wall Top Cap

1

5 3Scale: 3/4" = 1'-0"

X0043 Custom POS Toe Kick4

Scale: 3" = 1'-0"2 POS Toe Kick

Scale: 3/4" = 1'-0"7 X0027 10' Nook Wall Planking DetailScale: 3" = 1'-0"

Wall Plank Lighting Detail

6

8

91011

1

no. description date

Page 20: plantas starbucks

7' -

0 1/

2"

5' - 7"

1' - 4 1/4" 0' - 8 1/4"

0' -

1 3/

4"0'

- 11

1/4

"

Custom CBS Counter TopBased on Design ID 11886Dimensions for modified items only

7' -

3 3/

4"

1' - 4"

Custom CBS PanelBased on Design ID 11912Dimensions for modified items only

1' - 3"0' - 0 3/4"

7' -

2"

Custom CBS DiewallBased on Design ID 12128Dimensions for modified items only

Plan

1' - 0 1/2"

6' -

11 3

/4"

Custom Sit-Here BarBased on Design ID 12802Dimensions for modified items only

Live Edge

Custom Sit -Here Sneeze GuardBased on Design ID 11993Dimensions for modified items only

7' -

1"

2' -

4 1/

4"1/

8"2'

- 4

1/4"

1/8"

2' -

4 1/

4"

3' -

6"

Custom BRW counter based on Deisgn ID 12776Dimensions shown for modified items only

Return backsplash at adjacent wall

Custom BRW counter based on Design ID 12776Dimensions shown for modified items only

Return backsplash at adjacent wall

7' -

0 1/

4"

10 1

/4"

1' -

0 1/

2"10

1/8

"9

3/4"

Custom countertop/top cap based on Design ID 11992Dimensions for modified items only

3' -

4"3'

- 0"

8 1/

2"2'

- 8"

7 1/2" 1' - 3 3/4"

7 1/2"

9' -

8 1/

2"

Stone counter to match profile ofstandard corian counter tops.

2' -

11 1

/2"

Custom Cabinet based on Design ID 11985Dimensions for modified items only.

Front ElevationCustom Partial Finish Wall Panel based on Design ID 11907Dimensions for modified items onlySee Casework finish schedule

3' - 4"

V.I.F.

3' - 0" 3' - 1 1/2"

V.I.F

.

6 5/

8"2'

- 5"

6"Finished Floor

3' - 4" 3' - 0" 3' - 1 1/2"

36" GatePlan

Elevation

1' - 5"

Custom Toe KickBased on Design ID 11970Dimensions for modified items only

Plan

Finished Floor

Plan

Elevation

6"2'

- 5"

1' - 4 1/4"

1' - 4 1/4"

Custom Panel based on Desigh ID 11907Dimensions for modified items onlySee Casework finish schedule

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

9:10

PM

A-505

0816.01

Author

Checker

05-25-2012

Starbucks Coffee Company

Casework Details

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 3/4" = 1'-0"

X0029 Custom CBS CounterTopScale: 3/4" = 1'-0"

X0017 Custom CBS PanelScale: 3/4" = 1'-0"

X0018 Custom CBS Diewall1 2 3 4 5 6

7

Scale: 3/4" = 1'-0"

X0030 Custom Sit-Here

8 12

Scale: 3/4" = 1'-0"

X0031 Custom Sneeze GuardScale: 3/4" = 1'-0"

X0048 Custom BRW Countertop

Scale: 3/4" = 1'-0"

X0049 Custom BRW CounterScale: 3/4" = 1'-0"

X0044 Custom CountertopScale: 3/4" = 1'-0"

X0056 Custom CabinetScale: 3/4" = 1'-0"

X0055 Custom Partial Wall Wood Cladding

Scale: 3/4" = 1'-0"

X0020 Custom Toe Kick

Scale: 3/4" = 1'-0"

X0053 Custom Panel9 10

11

no. description date

Page 21: plantas starbucks

1' -

0"

1' - 2" 1' - 2"

1' - 1 3/8" 1' - 1 3/8"

2' - 4"

Elevation

Plan

Custom Drum Pendant Similar to X0013

1' -

4"

GWB Ceiling8'-0" A.F.F.

1' -

0"

2' - 10"

3' - 0"

1' - 6" 1' - 6"

3' - 3" 3' - 3"

6' - 6"

6' - 4"

Custom Lamp Shade with custom lamp X0057 over Small SetteeSide Elevation Front elevation

EQ EQ

GWB Ceiling8'-0" A.F.F.

1' -

4"

Custom Lamp Shade with custom lamp X0057 over Large SetteeSide Elevation

Front elevation

1' -

0"

2' - 10"

3' - 0"

1' - 6" 1' - 6"

3' - 10" 3' - 10"

7' - 8"

7' - 6"

EQ EQ

GWB Ceiling8'-0" A.F.F.

1' -

4"

ACT MAIN AND CROSS TEE

ACOUSTICAL CEILING TILE

SLIDING BRACKET ATTACHED TO TEEFLANGE WITH 14x1/2" HEX-HEAD SHEETMETAL SCREWS

LIGHTING FIXTURE TRACKATTACHED TO SLIDING BRACKETABOVE ACT W/ #12x1 MTL. SCREWS@ 2'-0" O.C.

5"

6"

Electric conduit to support can light pendant

Powder coat can housing black

8'-0" A.F.F.

NOTE: Pendant typeinstallation for can lights notinstalled in new gyp ceiling only

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

9:14

PM

A-506

0816.01

Author

Checker

05-25-2012

Starbucks Coffee Company

Light Fixture Details

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 3/4" = 1'-0"

X0057 Custom Drum PendantScale: 3/4" = 1'-0"

X0058 Custom Lamp ShadeScale: 3/4" = 1'-0"

X0059 Custom Lamp Shade2 3 4

Scale: 3/4" = 1'-0"1 Track Mounting

no. description date

Scale: 3" = 1'-0"5 Suspended Can Light Pendant

Page 22: plantas starbucks

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

9:22

PM

A-601

0816.01

Author

Checker

05-25-2012

Starbucks Coffee Company

Schedules

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Signage ScheduleDesign ID Count Description Responsibility Bulb Comments

Signage13181 2 Sign - Disk DF Illuminated Suspended

Evolved - 18in 455mmSB

Furniture ScheduleDesign ID Count Description Responsibility Comments

22 Air Hockey Table6 Ping Pong Table

Fixed Multiple Seating12184 30 Table - Base Cafe Dome Accent - 12x28in

305x710mm - Hot Rolled Steel MT0011SB

12193 3 Table - Base Fixed Dome Accent andGussets - 36in 915mm - Hot Rolled SteelMT0011

SB See Casework for custom Queue Railcounter top

X0001 8 Table - Base Bar Height Dome Accent -18x42in - Hot Rolled Steel MT0011

SB

Furniture & Accessories9

12303 38 Chair - Cafe Square Back - Dark BrownWD0009

SB

X0002 4 Table - Occasional Solid Walnut Top, clearfinish with Hairpin Legs

SB Icon Modern

X0003 34 Chair - EMECO Navy Chair - BrushedAluminum

SB Brushed Aluminum - Icon Modern

X0004 11 Chair - EMECO Navy Barstool - BrushedAluminum with wood seat 30"

SB Brushed Aluminum with Walnut Seat - IconModern

X0005 3 Ottoman - L2R Ottoman - Walnut withCream White - 002

SB MFG: InMod - www.inmod.com

X0006 4 Chair - L2R Lounge Chair - Tan Walnut w/cream white - 002 Leather Seat

SB MFG: InMod - www.inmod.com

X0032 1 InMod - Brades Loveseat - 66in - Code#kens-ls-brades - in Cream

SB MFG: InMod - www.inmod.com

Movable Multiple Seating10513 7 Table - Cafe Metal Suite Round - 28in

710mm - Black MT0022SB

10818 3 Table - Cafe Legs Set of 4 - 28in - BlackPowder Coat

SB

12149 16 Chair - Cafe Slatted Metal Suite - BlackMT0022

SB

12160 1 Table - Accessible Metal Suite - 39x23in990x585mm - Black MT0022

SB

X0008 3 Table - Cafe Top Square - 38in - SolidWalnut, clear finish

SB Based on Design ID 11051 - Icon ModernWD0001

X0009 2 Custom Community Table Top 42" x 11'-0"with live edge

SB Solid Reclaimed Walnut top - WD0001 with1/4" Thick Tube Steel Legs - Icon Modern

X0010 8 Custom Table - Top Square - 24in - Corian SB CP0017X0033 30 Table - Top Round Corian - 24in SB CP0017

Specialty Equipment ScheduleDesign ID Count Description Responsibility Comments

111901 1 Condiment Cart Pan SST - 38x13in SB12023 2 Sugar Dispenser SST - 17in SB

Bath & Toilet Accessories10977 1 Paper Towel Dispenser Full Size -

Translucent GreySB

11115 1 Soap Dispenser Sink Mounted SBFire Extinguishers

10501 1 Fire Extinguisher LCFood Service - Appliances & Equipment

10102 1 Ice - Bin 590lb SB10344 1 Ice - Bin Drop In 95lb SB10452 4 Brewer Warming Stand SB10473 1 Fridge Undercounter 2 Door - 48in SB10475 1 Ice - Machine 1109lb Air Cooled Side Vent SB10495 1 Brewer Dual SB10527 1 Ice - Bin Drop In 45lb SB10724 1 Grinder Grindmaster SB10797 1 Pastry Case with Self Serve - 66in -

BronzeSB

10917 4 Brewer Server SB10967 1 Freezer Reach In 2 Door - 51in SB11083 1 Fridge Reach In 2 Door - 51x35in SB12407 1 Oven TurboChef Next Generation SB12480 1 Fridge 1 Door with Countertop - 29in - SST SB12508 2 Blender Quiet Model On Counter SB12618 1 Fridge Undercounter 1 Door with Shelf -

27in 685mmSB

12694 2 Espresso Machine Mastrena SB13238 2 Airpot SB

Other Equipment10091 2 Cup Dispenser Tall Hot Vertical SB10314 1 Scale Digital with Adjustable Display

MountSB

10396 2 Cup Dispenser Short Hot Vertical SB10439 2 Cup Dispenser Grande Venti Hot

HorizontalSB

10757 1 Cup Dispenser Tall Cold Horizontal SB10788 1 Cup Dispenser Tall Hot Horizontal SB10855 4 Cup Dispenser Grande Venti Hot Vertical SB10947 1 Soap Dispenser Wall Mounted SB11055 2 Cup Dispenser Grande Venti Cold

HorizontalSB

11737 1 Cup Dispenser Short Hot Horizontal SBParts Bins

10305 1 Trash Drop Ring Liner Square - Black SB11061 4 Trash Drop Ring Round SB

Shelving10222 1 Wire Shelf Grid at Sink SB10416 9 Workroom Wire Shelving SB10462 9 Workroom Wire Shelving Posts SB10698 1 Mop Rack with 3 Holders SB10838 1 Rolling Wire Cart for 3 Comp Sink SB

Solid Waste Handling Equipment11070 1 Dishwasher Sanitizer SB

Graphics ScheduleDesign ID Count Description Responsibility Comments

Movable Artwork12860 1 Menu Board - 3 Panel Insert Style

Universal MountSB

12976 1 Menu Board - Daily Offering ChalkboardUniversal Mount Rectangular

SB

X0035 1 Framed Image NS0020 LS 2" Wood Frame to match WD0001 with 3"white matte

X0036 1 Framed Image NS0020 LS 2" Wood Frame to match WD0001 with 3"white matte

X0037 1 Framed Image NS0042 LS 2" Wood Frame to match WD0001 with 3"white matte

X0038 1 Framed Local Relevant Image Img001 LS 2" Wood Frame to match WD0001 with 3"white matte

X0039 1 Framed Local Relevant Image Img005 LS 2" Wood Frame to match WD0001 with 3"white matte

X0040 1 Framed Local Relevant Image Img011 LS 2" Wood Frame to match WD0001 with 3"white matte

X0041 1 Framed Local Relevant Image Img027 LS 2" Wood Frame to match WD0001 with 3"white matte

X0042 1 Mural NS0142 LS Mural NS0142 - Cropped to fit wall with 6"wood frame to match WD0001

Plumbing Fixture ScheduleDesign ID Count Description Responsibility Comments

1 EZ ADACold Water Service

10153 1 Faucet - Water Tower - 12in SBFloor Drains

10294 5 Drain - Floor Sink Square - 12in GC Refer to Penetration Plan for Tag &Locatoin

Food Service Equipment10874 1 Insta Hot Tap SB

Other Plumbing Fixtures10152 1 Faucet - Double Laboratory with Bent

Riser Spout10215 2 Faucet - Double Laboratory with Swing

SpoutSB

10447 1 Faucet - Pre Rinse Sprayer Wall Mounted SB10597 2 Faucet - Single Handle SB10922 1 Faucet - Mop Sink Wall Mounted SB11003 1 Faucet - Dipperwell SB

Sinks3

10505 1 Sink - Rinse Drop In - 27x20in SB10549 1 Sink - Work Drop In SST - 12x20in SB10581 1 Sink - Work Wall Mounted SST SB10719 1 Sink - 3 Comp Work SST - 88in SB10995 1 Sink - Mop - 24in GC

Urinals - Single1

Water Closets - Single3

Lighting Fixture ScheduleDesign ID Count Description Responsibility Bulb Comments

11154 8 Troffer - Recessed - 24x24in 610x610mm -White

SB

11458 21 Can - Adjustable Recessed Housing - 5in125mm - New Ceiling

SB

11533 72 Can - Recessed Housing - 5in 125mm -New Ceiling

SB

12934 4 Track - with Connectors - 4ft 122cm -White

SB

12956 16 Track - Fixture Open Flared - 3.5in 90mm -White

SB

13242 21 Can - Adjustable Recessed Trim - 5in125mm - White

SB GC to paint trim to match adjacentsurfaces

13244 72 Can - Recessed Trim - 5in 125mm - White SB GC to paint trim to match adjacentsurfaces

X0011 2 Floor Lamp - Mitra Floor Lamp BySonneman

SB (2) 26 Watt 120 Volt GU24 BaseFluorescent lamps

Lumens - Item #R303415 in Black Brass -www.lumens.com - Refer to FF&E Plan forTag & Location

X0012 3 Pendant -Loft - Maple by Fredric Ramond SB (1) 4.8 Watt 120 Volt Type GU24LED lamp

Lumens - Item #R302950 -www.lumens.com - Refer to FF&E Plan forTag & Location

X0013 10 Pendant - Fabric Drum - 22in SB (1) 200 Watt 120 Volt Type AIncandescent lamp

Lumens - Item #R039760 - Buster Pendantby Robert Abbey - Deep Patina Bronzewith Muslin Claiborne Fabric -www.lumens.com - Refer to FF&E Plan forTag & Location

X0014 6 Task Light - 24in - Manufacturer: LSI,Model: LDL2 24

SB LSI - www.lsi-industries.com

X0057 4 Custom Pendant - Fabric Drum - 28in SB (1) 200 Watt 120 Volt Type AIncandescent lamp

Similar to Lumens - Item #R039760 -Buster Pendant by Robert Abbey -www.lumens.com - Refer to FF&E Plan forTag & Location

X0058 1 Custom Settee Lamp Shade - Small SB Custom Lamp Shade - see design detailsX0059 1 Custom Settee Lamp Shade - Large SB Custom Lamp Shade - see design details

Lamp ScheduleDesign ID Count Description Responsibility Comments

12906 16 LED PAR 20 1-9w Nfl - White SB13257 21 LED PAR 30S 10-19w Flood SB

Lighting - Fluorescent19

11260 12 FL T5 8w 3000K SB12871 72 CFL T4 Biax 18w 2700K SB12893 16 FL T8 U 32w 3000K SB

Note: All responsibilities to be confirmed withStarbucks DM prior to ordering / construction

Responsibility Legend - Licensed StoresFC Provided by Starbucks - Installed by Fixture ContractorGC Provided by General Contractor - Installed by General ContractorLC Provided by Licensee - Installed by General ContractorSB Provided by Starbucks - Installed by General Contractor

*All custom furniture itpens to be provided by Icon Modern Contact:[email protected]: 312-560-2067Unless otherwise noted.

Data Device ScheduleDesign ID Count Description Responsibility Comments

Public Address & Music Systems10005 1 Music System SB10017 7 Speaker Surface Mounted - (Designer

Specify) White or BlackSBSB

10076 1 Amplifier SB

no. description date

Page 23: plantas starbucks

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

9:31

PM

A-602

0816.01

Author

Checker

05-25-2012

Starbucks Coffee Company

Schedules

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Casework ScheduleDesign ID Count Description Responsibility Comments

11155 2 Espresso Machine Pump Mount - 10x10in FC11900 1 Condiment Cart Island Top Solid Surface -

59inFC See casework finish schedule

11902 1 Cabinet - Upper Cubby - 27x16x14in FC11915 1 Countertop - Hand Sink Stainless - 15in

380mmFC

11930 1 Countertop - Espresso Inline IntegralRinse Sink Stainless - RH - 96in

FC See casework finish schedule

11933 1 Countertop - Warming Solid Surface - 16in405mm

FC See casework finish schedule

11942 1 Cabinet - Warming with Drawer - 16in405mm

FC

11945 1 Cabinet - 12in 305mm FC11956 1 Cabinet - Upper Cubby - 28x16x28in

700x405x720mmFC

11959 1 Fit Kit - Upper Cubby - Variable to 9in230mm

FC

11971 3 Cabinet - Sink or Ice Bin - 15in FC11972 1 Cabinet - Espresso with Cup Dispenser -

24inFC

11973 1 Condiment Cart Island Base - 59in FC See casework finish schedule11977 9 Cabinet - Upper Cubby - 24x16x21in

610x405x535mmFC See casework finish schedule

11993 1 Espresso Inline Sneeze Guard for 126in FC11994 1 POS Double Server Shroud - 30in 760mm FC See casework finish schedule12007 1 Cabinet - Sink - 24in FC12014 1 Cabinet - Door with Blocking - 15in 380mm FC12080 2 Cabinet - 15in 380mm FC12082 1 Cabinet - CBS Ice Bin - LH - 24in FC12091 1 Countertop - Handoff Rounded Stone - RH

- 30x33inFC See casework finish schedule

12096 2 Cabinet - with Drawer - 15in 380mm FC12098 1 Cabinet - Brew Grind - 24in 610mm FC12100 3 Espresso Countertop Support Leg

StainlessFC

12127 1 Cabinet - POS with Cup Dispenser Panel -30in 760mm

FC

12816 4 French Cleat - Variable 12in to 96in FC 20' -5" Total Length12816 1 French Cleat - Variable to 96in 2440mm FC Designer To Verify Quantity. Provide

Overall Length Required12845 5 Soffit - Light Valance - 96x2in FC 23'-3" Total Length12845 1 Soffit - Light Valance - 96x2in 2440x50mm FC Designer To Verify Quantity. Provide

Overall Length Required13287 1 Countertop - POS Double Server Solid

Surface - 30in 760mmFC See casework finish schedule

X0016 1 Custom Queue - 10" x 7'-0" SB Top Cap - See CW finish scheduleX0020 1 Custom Scale Toe Kick Corner - 15in

380mmFC Based on Design ID 11970

X0029 1 Custom Countertop - CBS Shared RinseSink and Ice Bin L Shape Solid Surface -LH - 84x67in

FC See Casework Finish Schedule

X0031 1 Custom Sit Here Sneeze Guard FC Based on Design ID 11993X0034 1 Fit Kit - Custom Upper Cubby End Piece -

3 1/8"FC Based on Design ID 11959, See casework

finish scheduleX0043 1 Custom POS Toe Kick Corner FC Based on Design ID 11916, See casework

finish scheduleX0044 1 Custom Countertop - Scale Stone - 15in

based on 11992FC Based on Design ID 11992, See casework

finish scheduleX0048 1 Countertop - Brew Grind Solid Surface -

LH - 57inFC Based on Design ID 12776, See casework

finish scheduleX0049 1 Custom Countertop - Brew Grind Work

Sink and Trash Solid Surface - LH - 93inFC Based on Design ID 12779, See casework

finish scheduleX0050 1 Custom Cabinet - POS with Filler - RH -

29inFC Based on Design ID 12086, See casework

finish scheduleX0051 1 Custom Cabinet - POS with Filler - LH -

29inFC Based on Design ID 11990, See casework

finish scheduleX0052 1 Countertop - POS Double Server Stone FC Based on Design ID 12788, See casework

finish scheduleX0056 1 Custom Cabinet - Scale - 15in FC Based on Design ID 11985, See casework

finish scheduleFixed Casework

11912 1 Panel - Espresso Inline - RH - 126in FC See Casework Finish Schedule11957 1 Panel - Cup Dispenser FC12103 1 Diewall - Inline Handoff Support - RH FC12128 1 Diewall - Espresso Inline - RH - 126in FC12775 1 Panel - POS Double Server - 30in 760mm FC12802 1 Diewall - Espresso Inline Top Cap - RH -

126inFC See casework finish schedule

X0017 1 Panel - CBS - RH - 126in FC See Casework Finish ScheduleX0018 1 Diewall - CBS - RH - 126in FCX0030 1 Diewall - Sit-Here Top Cap - RH - 126in FC See casework finish scheduleX0046 1 Custom Partial Wall Cap FC See Casework Finish ScheduleX0047 1 Custom Partial Wall Cap FC See Casework Finish ScheduleX0053 1 Panel - Scale - 16in 405mm FC Based on Design ID 11907, See casework

finish scheduleX0054 2 Panel - POS - 45in based on 11951 FC See Casework Finish ScheduleX0055 1 Panel - Partial Height Wall FC Based on Design ID 11907, See casework

finish scheduleX0060 19 Suspended Lamlite Ceiling panel SB 3/4" thick Lamlite Panel with Walnut

VeneerFixed Multiple Seating

X0021 2 Custom U-Shape Settee FC based on 12844 - Moore + Giles - Leather;Brighton in "Spice" - Refer to CaseworkFinish Schedule and details 1/I-502,2/I-502, and 3/I-502

X0022 1 Banquette - with Thick Seat FC based on 12844 - Moore + Giles - LeatherSeat; Brighton in "Chocolate"; Back:Maharam; Pattern: Crush 464780, in "001Feather" - Refer to Casework FinishSchedule and details 1/I-502, 2/I-502, and3/I-502

X0023 1 Custom High Banquette FC based on 12844 - Moore + Giles - LeatherSeat; Brighton in "Chocolate"; Back:Maharam; Pattern: Crush 464780, in "001Feather" - Refer to Casework FinishSchedule and details 1/I-502, 2/I-502, and3/I-502

X0024 4 Custom L-Shape Settee FC based on 12844 - Moore + Giles - Leather;Brighton in "Spice" - Refer to CaseworkFinish Schedule and details 1/I-502,2/I-502, and 3/I-502

Furniture & AccessoriesX0045 3 Coat Hook 2 Prong FC Rejuvenation Cast Iron Double Hook Item

# C0189 from rejuvenation.com888-401-1900

Finish - Ceiling TreatmentDesign ID Area Description Responsibility Comments

X0015 1091 SF Wood Planking - 1x4 - 16'-0" Bd cut to fit FC 16' Boards cut to fit; see casework finishschedule

Finish - Floor TreatmentDesign ID Area Description Responsibility Comments

11158 19 SF Walk off Mat GC11289 3399 SF Concrete Stain - Dark Brown GC GC to infill score cuts with grout to match

concrete12910 3324 SF Vinyl - Resilient Tile - Light Grey GC Provided

Finish - Wall BaseDesign ID Length Description Responsibility Comments

11403 488' - 2 3/4" Tile Base - Jackson Nero - 6x12in150x305mm

Grout Specification 008: Mapei 10 - Black;Laticrete 45 - Raven

Finish - Wall Treatment (Area)Design ID Area Description Responsibility Comments

11428 824 SF Plastic - Fiberglass Reinforced Panel -Almond

GC Marlite P-100 - White.090 FRP

12226 893 SF Tile - Olive Grey Mosaic - 6x24in150x610mm

SB Grout Specification 009: Mapei 11 -Sahara Beige; Laticrete 24 - Natural Grey

12320 178 SF Tile - Mottled Dark Brown - 2x8in50x205mm

SB Grout Specification 007: Mapei 47 -Charcoal; Laticrete 35 - Mocha

X0027 317 SF Plank B - 1x6 FC 10' Boards cut to fit; See casework finishschedule

Finish - Wall Treatment (Length)Design ID Length Description Responsibility Comments

Wall Finishes - CoveringsX0025 57' - 7 3/4" Chair Rail - 4in (100mm) GC See Casework Finish Schedule for

MaterialX0063 56' - 6 1/4" Leather - Wall Covering - L0003 Brighton,

Spice - 36in (915) AFF 2SB Moore + Giles L0003 Brighton, Spice 36in

X0064 1' - 5" Leather - Wall Covering - L0003 Brighton,Spice - 40.5in (915) AFF 2

SB Moore + Giles L0003 Brighton, Spice40.5in

Finish - PaintColor Code Material: Description LRV Responsibility Comments

SW - Dapper Tan ; NCS / Akzo Nobel -Rough Hewn

24 SW use CP-1 Primer; NCS - S5010 Y10R ;Akzo Nobel - 20YY 24/177

P546-SG SW - Library Pewter 20 GC SW use CP-1 PrimerP551-ES SW - Wool Skein 64 GC SW use CP-1 PrimerP551-SG SW - Wool Skein 64 GC SW use CP-1 PrimerP552-ES SW - Mega Greige 20 GC SW use CP-1 PrimerSW6272 SW6272 Plum Brown Accent Walls 7 GC SW use CP-1 Primer

Note: All responsibilities to be confirmed withStarbucks DM prior to ordering / construction

Responsibility Legend - Licensed StoresFC Provided by Starbucks - Installed by Fixture ContractorGC Provided by General Contractor - Installed by General ContractorLC Provided by Licensee - Installed by General ContractorSB Provided by Starbucks - Installed by General Contractor

CW Finish - NCS Regional ModernLocation Description Finish Code Comments

Concept FinishBackbar Casework Exterior Plastic Laminate - Medium Tone

Brown with GrainPL0014

Backbar Countertops Composite - Dark Grey withFlecks

CP0001

Backbar Storage Cubbies Plastic Laminate - Medium ToneBrown with Grain

PL0014

Condiment Cart Top Composite - Dark Grey withFlecks

CP0001

Condiment Cart, Etagere, Merch Bay Exterior Plastic Laminate - Medium ToneBrown with Grain

PL0014

Espresso Countertops Stainless Steel - #4 Brushed16ga SST

Espresso Countertops, Handoff Composite - Black Recycled CP0007Espresso Finish Panel Trim, Coffee Shuttle Shroud Hot Rolled Steel with Matte

SealerMT0011

Espresso Finish Panels Wood - Warm Brown Dark Tone,Distressed

WD0019

Espresso Top Cap Wood - Warm Brown Dark Tone,Distressed

WD0001 Live Edge

Espresso Wing, Handoff Finish Panels Wood - Warm Brown Dark Tone,Distressed

WD0019

Finish Panel Brackets Cold Rolled Steel MT0002Partial wall finish panels @ bar Wood - Warm Brown Dark Tone,

DistressedWD0019

POS, Frontbar Countertops Composite - Black Recycled CP0007POS, Frontbar, POS Cash Corral Finish Panels Wood - Warm Brown Dark Tone,

DistressedWD0019

Sit-Here Bar Wood - Warm Brown Dark Tone,Distressed

WD0001 Live edge

Miscellaneous FinishBanquette & Settees Wood - Warm Brown Dark Tone,

DistressedWD0001

Chair Rail Wood - Warm Brown Dark Tone,Distressed

WD0001

Core Casework Interior Plastic Laminate - Almond(ST655-S)

Custom Partial Wall Cap, X0044 Composite - Black Recycled CP0007Custom Wall & Ceiling Planking Wood - Walnut Clear FinishDuplex Outlets in Wainscot Locations to match adjacentsurfaces

Switchplate - Part #4752-112-CDVenetian Bronze

GC supplied

Espresso, Customer Bar Sneeze Guard Tempered GlassEspresso, Customer Bar Sneeze Guard Hardware Stainless Steel - #4 Brushed

16ga SSTEspresso, POS, Frontbar Cabinet Back Plastic Laminate - BlackHand Sink Countertop Stainless Steel - #4 Brushed

16ga SSTPartial wall top cap @ Settees X0046 & X0047 Composite - Dark Grey with

FlecksCP0001

POS, Frontbar Cabinet Side Plastic Laminate - BlackQueue Rail Top Cap Wood - Warm Brown Dark Tone,

DistressedWD0001 Live Edge - 2

SidesSuspended Ceiling Panels X0057 Lamlite panel with Walnut

VeneerClear Finish

no. description date

Page 24: plantas starbucks

Receptacle for Grinder/Scaleat 26" (660mm) AFF

Receptacle for Brewerat 26" (660mm) AFF

Double duplex receptacle for CoffeeWarmers at 26" (660mm) AFF

2' - 7" 1' - 8 3/4" 2' - 6 1/4"

8' - 6"

Receptacle for UndercounterRefrigerator at 26" (660mm) AFF

Receptacle(s) for Blender(s) at26" (660mm) AFF.

Receptacle and Data junction boxfor Cup Labeler at 26" (660mm)AFF

Optional Cup Labeler

7' - 0 1/2"

5' -

7"

2' - 10" 0' - 9" 1' - 2" 1' - 9"

Toe Kick (below)

Optional Espresso Machine layout

Receptacles for Espresso Machinesat 26" (660mm) AFF

Receptacle for Instant Hot WaterTap at 26" (660mm) AFF

21"x3" (530mmx75mm) stub-uppenetration area for Power and Data.See Electrical Plan for final location

Receptacle for UndercounterRefrigerator at 26" (660mm) AFF

Toe Kick

Receptacle and Data junction box forCup Labeler at 26" (660mm) AFF

Receptacles for Espresso MachinePumps at 26" (660mm) AFF

0' - 10" 1' - 0 1/4" 2' - 5 1/4" 1' - 0 1/4" 2' - 3"

Receptacle and Data junction box forCup Labeler at 26" (660mm) AFF

Receptacles for Espresso Machinesat 26" (660mm) AFF

Countertop (above)

Plan View

Electrical Components

Box base (below)

Receptacle for Coffee Warmer at 18"(460mm) AFF

Double duplex receptacle at 18" (460mm)AFF

18"x3" (460mmx75mm) stub-uppenetration area. Supply Power,Data, and Phone conduits for POS,and Power conduit for Pastry Case.See Electrical Design Plan for finallocation

Juntion box for Phone at 18"(460mm) AFF

Box base

Dedicated POS duplex receptacle at18" (460mm) AFF

Data Junction Box at 18" (460mm) AFF

Double duplex receptacle at 18" (460mm)AFF

1' - 10 1/4" 1' - 10" 2' - 6"

Dedicated POS duplex receptacle at18" (460mm) AFF

Countertop (above)

Plan View

Electrical Components

Receptacle for Warming Ovenat 26" (660mm) AFF

Double duplex receptacle for Refrigeratorand Cup Labeler at 26" (660mm) AFF

Data Junction Box for CupLabeler at 26" (660mm) AFF

0' - 9 3/4"0' - 6 1/4"

Clear

2' - 6"

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

9:40

PM

A-801

0816.01

Author

Checker

05-25-2012

Starbucks Coffee Company

Enlarged Electrical Plans

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 3/4" = 1'-0"1 Brew 05 - Electrical

Scale: 3/4" = 1'-0"2 CBS 07- ElectricalScale: 3/4" = 1'-0"3 Espresso 10 - Electrical

Scale: 3/4" = 1'-0"4 POS 17 - ElectricalScale: 3/4" = 1'-0"5 Warming 01 - Electrical

no. description date

Page 25: plantas starbucks

Tempered hot and cold waterfor Sink Faucet at 20 1/2"(520mm) AFF. Shut-offvalves at wall and 4" (102mm)either side of waste line

Direct drain line fromSink. Rough-in sinkwaste stub at 15 1/2"(394mm) AFF andcenterline of sink

1' - 3"

0' - 7 1/2"

Hot and cold water for SinkFaucet at 20 1/2" (520mm)AFF. Shut-off valves at walland 4" (102mm) either side ofwaste line

Direct drain line from Sink.Rough-in sink waste stub at15 1/2" (394mm) AFF andcenterline of sink

Filtered Cold Water supply forBrewer with shut-off in cabinetat 24" (610mm) AFF8' - 6"

5' - 7 1/2"

See Plumbing Plan for final floor sink locationand type

Hot and cold water for Sink Faucet at 201/2" (520mm) AFF. Shut-off valves at walland 4" (102mm) either side of waste line

Indirect drain line from Drain Boardto floor sink

Indirect drain line from Sink to floor sink

Cold water supply for Pitcher Rinser

Indirect and insulated drain linefrom Ice Bin to floor sink

4' -

7"

5' -

7"

2' - 5 1/2"

7' - 0 1/2"

Legs (below)

Indirect drain line from EspressoMachine to floor sink (typ)

Indirect drain line fromIn-use Utensil RinseSink to floor sink

7"x3" (180mmx75mm)stub-up penetration area.See Plumbing Plan forfinal locations.Install shut-off valvesbetween stub-ups andequipment

Toe Kick

See Plumbing Plan for finalfloor sink location and type.Coordinate location withsupport legs

Filtered Cold water supply forInstant Hot Water Tap

Filtered Cold water supplyfor Water Tower Faucet

Cold water supply forMetered spoon rinser faucet

Filtered Cold water supply forEspresso Machine (typ)

Hot and Cold water supplyfor Pitcher Rinser faucet

Toe Kick (below)

Optional Espresso Machine layout

Countertop (above)

Legs

7' - 4 3/4"

2' -

3 1/

4"

Floor sink (below)

Plan View

Plumbing Components

Legs (below)

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCStudent Center113 Union DriveClemson, SC 29634

8/3/

2012

5:1

9:48

PM

A-802

0816.01

Author

Checker

05-25-2012

Starbucks Coffee Company

Enlarged Plumbing Plans

McKnight Smith Ward Griffin Engineers, Inc.4223 South Blvd.Charlotte, NC 28209704-527-2112 X156mswg.com

MEP

Scale: 3/4" = 1'-0"1 ADD 01 - PlumbingScale: 3/4" = 1'-0"2 Brew 05 - Plumbing

Scale: 3/4" = 1'-0"3 CBS 07 - PlumbingScale: 3/4" = 1'-0"4 Espresso 10 - Plumbing

no. description date

Page 26: plantas starbucks

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCHarcombe Dinning Hall113 Union DriveClemson, SC 29634

6/5/

2012

8:0

1:27

AM

0816.01

07-31-2012

Starbucks Coffee

MEP

no. description date

08-03-2012

MECHANICAL DEMO PLAN M100

MSB, DAC

JCC

Page 27: plantas starbucks

Men's

Restroom

Bar

Cafe

Seating

Workroom

Women's

Restroom

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCHarcombe Dinning Hall113 Union DriveClemson, SC 29634

6/5/

2012

8:0

1:27

AM

0816.01

07-31-2012

Starbucks Coffee

MEP

no. description date

08-03-2012

Mechanical Floor Plan M101

MSB, DAC

JCC

Page 28: plantas starbucks

Mechanical Schedules & Details M201

MSB, DAC

JCC

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCHarcombe Dinning Hall113 Union DriveClemson, SC 29634

6/5/

2012

8:0

1:27

AM

0816.01

07-31-2012

Starbucks Coffee

MEP

no. description date

08-03-2012

Page 29: plantas starbucks

Cafe

Seating

Workroom

Women's

Restroom

Men's

Restroom

Bar

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCHarcombe Dinning Hall113 Union DriveClemson, SC 29634

6/5/

2012

8:0

1:27

AM

0816.01

07-31-2012

Starbucks Coffee

MEP

no. description date

08-03-2012

PLUMBING PLAN P101

AKE

DAC

Page 30: plantas starbucks

dwg no.

project no.

drawn

checked

project date

kenneth w. tipton, jr., aiabryon m. hume, aiadarrin l. badon, aiadaniel m. zito, aia

449 westmoreland drivebaton rouge, louisiana 70806

ph 225.387.0101fax 225.387.0104

www.tipton-associates.com

revisions

Clemson University, SCHarcombe Dinning Hall113 Union DriveClemson, SC 29634

6/5/

2012

8:0

1:27

AM

0816.01

07-31-2012

Starbucks Coffee

MEP

no. description date

08-03-2012

SCHEDULES & DETAILS P201

AKE

DAC

Page 31: plantas starbucks

dwg no.

project no.

drawn

checked

project date

revisions

Clemson University, SCHarcombe Dinning Hall113 Union DriveClemson, SC 29634

6/5/

2012

8:0

1:27

AM

0816.01

07-31-2012

Starbucks Coffee

MEP

no. description date

S. Brown

M. Arrington

SYMBOLS AND SCHEDULES E100

Page 32: plantas starbucks

dwg no.

project no.

drawn

checked

project date

revisions

Clemson University, SCHarcombe Dinning Hall113 Union DriveClemson, SC 29634

6/5/

2012

8:0

1:27

AM

0816.01

07-31-2012

Starbucks Coffee

MEP

no. description date

S. Brown

M. Arrington

SYMBOLS AND SCHEDULES E100

Page 33: plantas starbucks

CafeSeating

Workroom

Women'sRestroom

Men'sRestroom

Bar

dwg no.

project no.

drawn

checked

project date

revisions

Clemson University, SCHarcombe Dinning Hall113 Union DriveClemson, SC 29634

6/5/

2012

8:0

1:27

AM

0816.01

07-31-2012

Starbucks Coffee

MEP

no. description date

S. Brown

M. Arrington

FLOOR PLAN - LIGHTING E201

Page 34: plantas starbucks

CafeSeating

Workroom

Women'sRestroom

Men'sRestroom

Bar

EXISTINGELECTRICAL

CLOSET

dwg no.

project no.

drawn

checked

project date

revisions

Clemson University, SCHarcombe Dinning Hall113 Union DriveClemson, SC 29634

6/5/

2012

8:0

1:27

AM

0816.01

07-31-2012

Starbucks Coffee

MEP

no. description date

S. Brown

M. Arrington

FLOOR PLAN - POWER E301

Page 35: plantas starbucks

dwg no.

project no.

drawn

checked

project date

revisions

Clemson University, SCHarcombe Dinning Hall113 Union DriveClemson, SC 29634

6/5/

2012

8:0

1:27

AM

0816.01

07-31-2012

Starbucks Coffee

MEP

no. description date

S. Brown

M. Arrington

POWER RISER DIAGRAM E401


Recommended