Plasma Low Temperature Sterilization PlazMax Line With vaporized hydrogen peroxide
Transcript
Page 1: Plasma Low Temperature Sterilization - Tuttnauer · Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization

Plasma Low Temperature Sterilization

PlazMax Line

With vaporized hydrogen peroxide

Page 2: Plasma Low Temperature Sterilization - Tuttnauer · Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization

2

Low Temperature Sterilization For heat and moisture sensitive equipment

PlazMax Line

PlazMax provides an efficient sterilization solution for

heat & moisture sensitive equipment in CSSDs and

Gastroenterology & Respiratory Endoscopy Clinics.

PlazMax will give you the lowest rate of failed cycles

than any other hydrogen peroxide plasma sterilizer on

the market. You get increased productivity, reduced

risk of work stoppage, and efficient supply of sterilized

equipment where it’s needed.

In operating rooms PlazMax benefits you with almost

immediate access to sterilized equipment. Simple to

install and control, only requiring 1-phase electricity

and Hydrogen Peroxide (H2O

2) packs to operate. No

need to send equipment to a CSSD, eliminating the

risk of damage and contamination in transit.

Page 3: Plasma Low Temperature Sterilization - Tuttnauer · Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization

3

PlazMax Line

Advanced and Flexible Control SystemTake Advantage of Tuttnauer’s state-of-the-art control system with multicolor touch screen display. Includes equipment tracking and maintenance notification features.

25 minutes Fast and ProductivePlazMax cycle times are as low as 25 minutes (P50 normal cycle).

Wide Range of ChambersDon’t over pay for two small sterilizers when you can buy one large sterilizer. Choose from 3 models with chamber sizes from 47 to 109 liters.

Keep Running Costs LowKeep you consumable costs low

With PlazMax you have the freedom to use commonly available market accessories such as indicators, pouches & rolls, etc. that are suitable for sterilization with vaporized hydrogen peroxide. Tuttnauer also sells sterilant, and biological & chemical tape indicators.

Clean Technology• Non-toxic sterilizing agent

• Minimal utility requirements – low electricity consumption, no water consumption

• The sterilization process results in water and

oxygen by-products

Vertical Sliding DoorAutomatic Vertical Sliding Door (P110 model only) with built-in foot operated device for hands-free door operation.

Tough Challenges – PCDBy challenging the PlazMax sterilizer with our Process Challenge Device (optional) you will be confident that it does its job at the highest sterilization levels.

Page 4: Plasma Low Temperature Sterilization - Tuttnauer · Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization

4

• 47 Liter Chamber

• Single or Double door

• Chamber Dimensions (WxHxD) 420 x 180 x 624 mm

• 83 Liter Chamber

• Single or Double door

• Chamber Dimensions (WxHxD) 420 x 320 x 624 mm

PlazMax P50

PlazMax P80

180mm

320mm

Page 5: Plasma Low Temperature Sterilization - Tuttnauer · Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization

5

PlazMax Line

Technical Specifications

Model VolumeLiters

Chamber Dimensions(WxHxD) mm

External Dimensions(WxHxD/D 2-doors) mm

No. of Baskets40x60 (WxD) cm

Power (W)Current (A)

Voltage V1-Phase50-60 Hz

P50 47 420 x 180 x 624 702 x 1528 x 729 / 736 1670W2.9A

230 V

P80 83 420 x 320 x 624 702 x 1668 x 729 / 736 2690W3.0A

230 V

P110 109 420 x 420 x 624 702 x 1768 x 729 / 736 21150W5.0A

230 V

Sterilization Cycle and Test Programs

ModelNormal Cycle

(Non-hollow loads)Advanced Cycle(Hollow loads)

Endoscope *

Cycle Time (min.) Cycle Time (min.) Cycle Time (min.)

P50 35 40 25

P80 35 40 25

P110 45 50 30

Test Cycles Description

Test I Penetration Test

Test II Leakage Test

* Endoscope cycle temperature: short heating time and reduced H2O

2 exposure time

• 109 Liter Chamber

• Single or Double door

• Chamber Dimensions (WxHxD) 420 x 420 x 624 mm

PlazMax P110

420mm

Page 6: Plasma Low Temperature Sterilization - Tuttnauer · Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization

6

Not Ready 09:31:32 | 6th Oc tober, 2013

SELECT

INIT

REMOVE

NEW...

Handle Endoscopes

1 BF 1 T 160 70 10 100 2/SEP/2013

2 BF 160 70 15 150 2/SEP/2013

3 CF Q 160 AL 100 12 224 2/SEP/2013

4 CF 2 T 160 L 70 18 321 2/SEP/2013

5 PCF 160 AL 100 10 154 2/SEP/2013

6 GIF Q 160 70 15 117 2/SEP/2013

7 GIF XP 160 100 10 258 2/SEP/2013

8 GIF PQ 20 70 13 132 2/SEP/2013

ID Name Max Current Total Last Init

Advanced Control System for Your CSSDTake advantage of Tuttnauer’s sophisticated user-friendly control systems for repeatable high performance. Choose either Tuttnauer’s sophisticated Bacsoft controller or the Allen-Bradley (AB 1400 PLC) controller.

Standard Features

• 7” Multi-color touch screen panel (also on second

door of two door configurations)

• Stores the last 200 cycles in built-in memory

• Multiple access levels and user passwords to control access/operation of the Plazmax

• Diagnostic In/Out test (enables technician to check each system component separately)

• Sterilization Temperature range 50°C to 55°C

• Thermal Printer

• USB and Ethernet connection port

Sophisticated Touch Screen HMIThe HMI (Human Machine Interface) has been designed with the following considerations:

• Multi-color display for easier reading from a distance

• Multilingual (26 languages)

• Dynamic graph displaying the chamber pressure and the cycle process

• Displays process info – pressure, temperature, vaporizer temp.

Equipment Tracking & Maintenance NotificationEquipment tracking software provides a detailed sterilization history of each endoscope tracked. The software will notify when equipment needs to be returned back to the original equipment manufacturer for maintenance.

Page 7: Plasma Low Temperature Sterilization - Tuttnauer · Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization

7

PlazMax Line

Reporting You Can Rely On• Automatic recording of cycle information to any PC on your

network• Convenient access to graphs and tables that are easy to understand• Easily generate PDF reports• No need to file printouts, saving you time

Be in Control with Real-Time Remote Monitoring

• See the real-time autoclave display on your PC

• Monitor all activity for up to 8 autoclaves

With R.PC.R you can see: Graphs of the cycle data, Numeric cycle data, cycle print-outs, measured values table, parameter table.

Automatic Recording of Cycle Information to Your PC

Standard

Optional

R.PC.R Software

Software and Hardware

USB Digital Cycle DataConnect a USB memory device to the PlazMax and you can download a soft copy of cycle printouts and all cycle data history stored in the sterilizer’s memory.

Remote network access for

technical Support (requires

R.PC.R) (requires local SIM

card for Internet connection)

R.PC.R software for access from PC or network

Thermal PrinterTouch screenDirect network accessfor technical Support (requires R.PC.R)

Page 8: Plasma Low Temperature Sterilization - Tuttnauer · Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization

8

SYSTEM READY 23:50:34 | 5TH OCTOBER, 2013

PRESSURE

TEMPERTURE

VAPORIZER

[mBar]

[°C]

[°C]

0968.8

056.0

136.0

SYSTEM STATUS

Ready to run cycle ‘Normal ’

PROCESS INFO

System ReadySystem ReadyNormal

Support Settings

H2O2

55%

DONE 00:08:01 | 6TH OCTOBER, 2013

PRESSURE

TEMPERTURE

VAPORIZER

[mBar]

[°C]

[°C]

0985.2

056.0

136.0

00:14:04

SYSTEM STATUS: WAITING FOR CONFIRMATION PROCESS INFO

DONEDONENormal

Support Settings

0.0

0.0 2.8 5.6 8.4 11.2 14.0

200.0

400.0

600.0

800.0

1000.0

1111

2222

3333

4444

5555

Sterilization Cycle Process

Page 9: Plasma Low Temperature Sterilization - Tuttnauer · Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization

9

PlazMax Line

How can you be sure your hollow instruments have been 100% penetrated?

Use Tuttnauer’s Process Challenge Device (PCD)

Tuttnauer’s PCD kit includes lumens that are more difficult to penetrate than your loads. With the PCD you can be certain your lumen loads are fully exposed to the vaporized hydrogen peroxide sterilizing agent.

The PCD kit includes long lumen configurations that cannot be successfully sterilized in competing devices.

The PCD Kit includes 1mm diameter lumens with lengths of 4m (both sides open) and 1.4m lumens (one side open).

Chemical indicators are used every cycle and in each package item to validate penetration and to ensure vaporized peroxide has made contact with the load.

4m with two sides open

1.4m one side open

Bio log i ca l ind i cators a re u sed according to a schedule required by a hosp i ta l ’s po l i cy and requ i re an incubator (optional) to facilitate the detection of micro-organisms. Biological indicators validate steril ization by helping determine that the sterilizer effectively kills the micro-organisms.

Safety Features

Tuttnauer strives to provide sterilizers that ensure safety for patients, staff, and the environment. Safety features include:

• No hazardous or odorous emissions • Low temperature and low pressure during sterilization • Door is locked during cycle operation

Page 10: Plasma Low Temperature Sterilization - Tuttnauer · Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization

10

Non-Hollow LoadsNon-hollow loads are sterilized with the “Normal Cycle”.

Hollow LoadsHollow loads are sterilized with the “Advanced Cycle”.

Laryngscope & blade

Surgical power drill

Shaver hand pieces

Laryngscope & blade

Thermometer

Laser probe Defibrillator paddlesElectrocautery Instruments Dopplers

Ophthalmic lenses Harmonic cable

Fiber optic light cable

• The instruments and equipment presented are only a partial list of the wide range that can be safely sterilized in PlazMax

• Only use PlazMax with equipment authorized by original manufacturer to be sterilized with plasma sterilizers.

Page 11: Plasma Low Temperature Sterilization - Tuttnauer · Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization

11

PlazMax Line

EndoscopesEndoscopes and similar equipment are sterilized with the “Endoscope Cycle”.

Flexible endoscope Flexible endoscopeRigid scope for optics Rigid scope

Page 12: Plasma Low Temperature Sterilization - Tuttnauer · Low Temperature Sterilization For heat and moisture sensitive equipment PlazMax Line PlazMax provides an efficient sterilization

Distributed by:

Your Sterilization & Infection Control Partners

Company Profile

For over 88 years, Tuttnauer’s sterilization and infection control products have been trusted by hospitals, universities, research institutes, clinics and laboratories throughout the world. Supplying a range of top-quality products to over 100 countries, Tuttnauer has earned global recognition as a leader in sterilization and infection control.

Global Partnership

At Tuttnauer we feel that business means people dealing with people. We pride ourselves on our reputation for having long-lasting relationships with our customers based on commitment and trust, spanning over decades and distances. Our Flexibility is Your Advantage

Beyond our wide range of products and ability to customize products to customer requirements, we also manage complete turnkey solutions, including planning, design and installation of equipment, as well as consultation and feasibility studies, for projects of all sizes.

International Sales and MarketingE-mail: [email protected]

Tuttnauer Europe b.v.Hoeksteen 11, 4815 PRP.O.B. 7191, 4800 GD BredaThe NetherlandsTel: +31 (0) 765 423 510, Fax: +31 (0) 765 423 540E-mail: [email protected]

Tuttnauer USA Co.25 Power Drive,Hauppauge, NY 11788Tel: +800 624 5836, +631 737 4850 Fax: +631 737 0720E-mail: [email protected]

Standards and Directives

PlazMax has been developed according to the following international standards and directives (partial list):

• ISO 9001:2008 • ISO 13485:2003 • ISO 14937 • EN 61010-2-040:2005 • EN 60601-1:2006/AC:2010