Date post: | 24-Jul-2015 |
Category: |
Services |
Upload: | uniqueindoorcomfortlibertyville |
View: | 87 times |
Download: | 1 times |
Trouble-shooting
Before
Using
Howto
UseMaintenance
AIR PURIFIER<Desktop type>
MODEL
MA-EF503HS-UMA-EF303HS-UINSTRUCTION MANUAL
Features● Plasma deodorization
For odors that cannot be removed even withactivated charcoal
● HEPA dust filtration● Sensors to detect dust particles,
pollen, and odors● Powerful and quiet● Hand-held remote control
CONTENTS Page
¡Safety precautions ..........................2¡Precautions .....................................4¡Names and functions of parts .........5¡Effective usage................................7¡Preparations....................................8
Setting the filtersInstalling the batteries for remote controller
¡Operation (viewing the monitor lamps)....9¡Changing the airflow .....................10¡Plasma air deodorization ..............11¡Off TIMER operation .....................11
¡Monthly cleaning ...........................12¡Yearly cleaning..............................13¡Replacing the filters ......................14
¡Troubleshooting.............................15¡Specifications ...............(back cover)
In order to ensure correct usage, please read thisinstruction manual carefully, and retain it for futurereference.
™
AC120V
WARNING
CAUTION
WARNING
Safety precautionsThe following displays categorize the degree of danger when mishandled.
Possibility of serious injury and even death, if mishandled.
Possibility of injury and damage to household furniture and surroundings.
The following symbols are defined as follows:
Prohibited Do not touchDo not usenear waterDo not
disassemble Do not get wet
Always follow
Remove thepower plug
Fire and/or electrical shockmay occur as a result.For repair, contact your dealer ofpurchase or Mitsubishi Electric.
Do not repair,disassemble or modify.
Do not damage the power cord.● Do not coat or bundle.● Do not place objects on top of
the cord.● Do not remove the power plug by
pulling on the cord.
Fire, electrical shock, and/ordamage may occur as a result.
Do not use damaged power cordor plug. Do not use damagedpower outlet where the plugcannot be inserted securely.
Electrical shock, short circuitand/or fire may occur as aresult.
Do not wash the Plasmaunit.
Using the Plasma unit when wet may cause fire and/orelectrical shock.
Do not insert finger orforeign objects into thedust sensor.
Electrical shock may occur asa result.
Remove the power plugwhen cleaning.Furthermore, never handle thepower plug with wet hands orget the plug wet.
Electrical shock and/or injurymay occur as a result.
Use an AC120V power outlet.
Electrical shock, short circuitand/or fire may occur as aresult.
Periodically remove dustfrom the power plug with adry cloth.
Dust build-up can cause badinsulation and a fire may occuras a result.
2
To reduce the risk of electricshock, this equipment has apolarized plug (one blade iswider than the other). This plugwill fit in a polarized outlet onlyone way. If the plug does not fitfully in the outlet, reverse theplug. If it still does not fit,contact qualified personnel toinstall the proper outlet. Do notalter the plug in any way.
CAUTION
Gas Gas
Gas
Oil Oil
Oil
Spra
y
Before
Using
3
Do not allow the unit to intakeflammable gases.Do not use where there isaccumulation of such flammablegases (factories, hair salons, etc.).
Explosion and/or fire mayoccur as a result.
Do not install in a locationsuch as a bathroom where theunit may get wet, and avoidplaces with high humidity.
Electrical shock and/ormalfunction may occur as a result.If the unit gets wet for some reason,stop operation, remove the powerplug and contact your dealer ofpurchase or Mitsubishi Electric &Electronics USA, Inc..
Do not use in a locationwhere there is lampsmoke,such as from machine oil,etc.
The unit may crack, resulting inelectrical shock and/ormalfunction.
Do not insert fingers or foreignobjects into the intake grill, theexhaust air port, or any smallopenings of the unit interior.
Electrical shock, malfunctionand/or injury may occur as a result.
Do not wipe with benzene orpaint thinner, and do not sprayinsecticides or deodorizers,etc., onto the unit.
Electrical shock, fire and/orcracking may occur as a result.
Do not remove the HEPAfilter with the unit laying onits back.
Dust may enter inside the unit,and fire and/or electricalshock may occur as a result.
Do not use damaged filters, oroperate the unit without a filter.Contact your dealer or MitsubishiElectric for a replacement.
Fire and/or electrical shockmay occur as a result.
Do not touch the electricpoles of the Plasma unit.
Injury may occur as a result.
Ventilate periodically whenusing the unit with aheating appliance, etc.
Insufficient ventilation maycause CO intoxication.
● Do not use rechargeable batteries.● Make sure that the and are correctly aligned.● When replacing, always replace batteries at the same time using
the same type.● If the electrolyte from the alkaline batteries comes into contact with
skin, wash thoroughly with water. If the electrolyte accidentallyenters your eye, flush with water and seek immediate medicalattention.
Remove the power plugwhen not using for anextended period of time.
Insulation may deteriorate,causing short circuit, fire and/orelectrical shock as a result.
Use the batteries correctly by following the items below.
Injury and/or malfunction may occur if mishandled.
Safety precautions
4
PrecautionsThis air purifier is for household use only. Do not use for business purposes.
Do not block the intake grill orthe exhaust air ports.
Malfunction may occur as a result.
Do not use if the unit is layingon its back or front.
Malfunction may occur as a result.
Do not use with the intakegrill, the filters or the Plasmaunit removed.
Malfunction may occur as a result.
Do not use the unit as aventilation fan or range hood.
This may drastically reduce theservice life of the filter as well ascause deformation, discolorationand/or malfunction.
If the remote controller comes into contact with aliquid, remove batteries and dry thoroughly.
If the remote controller becomes inoperable, contact your dealerof purchase or Mitsubishi Electric.
Take note of the following when installing the unitDo not install near or on top ofhot objects, such as a stove,etc.
Malfunction, deformation and/ordiscoloration may occur as a result.
Keep unit at least 3.3 feet (1m) away fromtelevisions, cordless telephones, airconditioners, computers, incandescentbulbs, fluorescent lighting, etc.
Electrical wave interference mayoccur, resulting in the remotecontrol becoming inoperable.
Do not use in a locationexposed to direct sunlight
Deformation and/or discolorationmay occur as a result.
Leave space around the unit
Walls and/or ceiling may becomedirty as a result.
2 feet (60 cm) or more above the unit and 0.7feet (20 cm) or more on the sides and back.
2 feet (60 cm)or more0.7 feet
(20 cm)or more
When carryingTurn the power switch to OFF,unplug the unit, and carry theunit by the handle.
Do not press strongly againstthe control panel when carrying.
Notes
How strong are the electromagnetic waves discharged by this air purifier?The electromagnetic waves produced by this product are lower than mobile phones, and are harmless to the bodyand medical equipment.
Can the unit remove odors of newly constructed houses?The unit may not be able to completely remove odors if the discharge of odors is too much such as with new paint orcarpet glues.
0.7 feet (20 cm)or more
0.7 feet (20 cm)or more
6~7
Main unit Accessories
Control panel
Before
Using
5
Names and functions of parts
Odor sensorDetects smell of cigarettes, etc.
Reset SwitchPress after replacing the filter.
Activated charcoal filter
Remote controller
Two AA typebatteries for theremote controller
Plasma unit
HEPA filter
Intake grill
Dust sensorDetects polluted air suchas pollen, etc.
Grill-release buttonPress to remove the grill.(On each side of unit)
Table stand
Air fan
Spring clips(On each sideof Plasma unit)
What is a HEPA filter?
<High Efficiency Particulate Air filter>The HEPA filter is a high performance filterthan can catch up to 99.97% of all particlesas small as 0.3 micron in diameter.
Handle
Exhaust airport
Power cord
<Removing>Lay the unit on its backside, and then remove thestand by pressing tablestand tabs.
<Replacing>Hook the tabs on the frontside of the table stand,and then press in the rearside of the stand.
Precautions
Nam
es and functions of parts
6~7
Removing and replacing the unit table stand
PLASMA
REPLACE FILTER
Control panel
Plasma deodorization lampON… Plasma deodorization in
processFlashing…Error 13
Odor sensor
Filter replacement lampWhen lit, it indicates that the filters should be replaced.
Remote sensor
How to use the remote controller 9
14
Plasma air deodorization 11
Viewing the monitor lamps 9
Odor monitor (odor sensor)Shows the level of air pollution caused by odor of cigarette smoke, etc.Microdust Monitor (dust sensor)Displays the level of air pollution caused by tinyparticles such as cigarette smoke, etc.Pollen Monitor (dust sensor)Displays the level of air pollution caused bylarge particles such as pollen, dead mites,dust, etc.
ODORMICRODUST POLLEN
How do the sensors work?Odor sensorUsing a semiconductor sensor, gases from odor ingredients are detected. The sensor will react to a breeze from air conditioners, fans, etc., as well as odorless gases and perfumes.
Dust sensor¡MICRODUST
Using an optical sensor, the number of particles less than approximately 1 micron is detected.
¡POLLENUsing an optical sensor, the number of particles more than approximately 1 micron is detected.
About microdust and pollen
100 (micron)1010.10.01
Pollen
Feces or dead body of mites, dust
Small particles of cigarette smoke
Dusts which are harmful to the lungs
MICRODUSTSmall particles such cigarette smoke, etc.(Mainly particles smaller than 1 micron)
POLLENLarge particles such as pollen, dead mites, etc.(Mainly particles of larger than 1 micron)
Replacing the filters
6
Names and functions of parts (continued)
Before
Using
7
TIMER FAN AUTO
NORMALPOLLENGUARDMINHOUR LOW MED HIGH MAX
POWERON/OFF
11 1010
15 15
Off TIMER lamps Show the remaining operation time (hours).
Off TIMER button¡Switches the timer ON¡Switches the timer OFF
Off TIMER operation
Changing the airflow
FAN level indicatorON: The fan level in operation is displayed.Flashing: Error
FAN button¡Switches operation modes
and airflow volume
Changing the airflow
Operation mode lampsPOLLEN GUARD lamp ON: Pollen guard in progressNORMAL lamp ON: Normal operation in progressFlashing: Error
AUTO buttonSwitches operation modes
POWER button¡Turns the unit ON¡Turns the unit OFF
9Operation
POWER
AUTO FAN
PLASMA TIMER
Remote control operation panel
1111
10Operation mode button¡Switches operation modes.
Plasma air deodorization switch (on the remote only)¡Plasma air deodorization
function ON¡Plasma air deodorization
function OFF
9
Operation switch¡Turns the unit ON¡Turns the unit OFF
Off TIMER switch¡Switches the timer ON¡Switches the timer OFF N
ames and functions of parts
Effective usage
10
Use by installing on a high platform
Table-top POLLEN GUARD operationPOLLEN GUARD, which reacts to even the slightest traces of pollen, is recommended.Since scattered dust and pollen fall gradually, install the unit in a low location for the best result.Running the unit all day is also recommended if you are concerned about pollen.
Since cigarette smoke rises directly upward, installing the unit in a high location is recommended such as on a counter or dresser.(Take caution so that the unit does not fall.)
Effective usageFor the best results from your product, install the unit where there is good aircirculation.
If you areconcernedaboutsmoke
If you areconcernedaboutpollen
1
3
2
4
512~13
+�
-�
+�
-�
1
2
3
Caution
8
PreparationSetting the filtersRemove the plastics from the HEPA filter and theactivated charcoal filter before use.
Press the grill-release buttons, andthen remove the intake grill.
Remove the HEPA filter.
Both sides
Remove the Plasma unit.
Hold the springclips, and removeone side at a time. Hold with both
hands, and pullto remove.
Install the activated charcoal filter.
Remove theplastic beforeinstalling.
Replace the Plasma unit, the HEPAfilter, and the intake grill.
Removethe plastic
(White particles within the activatedcharcoal filter are titanium oxide, notmildew.)
Installing the batteries forthe remote controller
While pushing the cover, slide itforward.
Insert the batteries.
Close the cover by sliding it backwarduntil it snaps shut.
Two AA type batteries
● Ensure that the proper polarity is observed.
Use dry cell batteries in a proper manner.● Do not use rechargeable batteries.● Make sure that the positive and negative poles
are correctly aligned.● When replacing, always replace with two new
batteries of the same type.● Should your skin come in contact with the
electrolyte of the alkaline dry cell batteries,wash the affected area with water. Should theelectrolyte enter your eye, immediately contacta doctor.
Wrong use may cause injury or malfunction.
Before
Using
9
Preparation
Operation
TIMER FAN AUTO
NORMALPOLLENGUARDMINHOUR LOW MED HIGH MAX
POWERON/OFF
beep, beep beep, beeepPOWERON/OFF
AUTO FAN
PLASMA TIMER
POWERPOWER
ODORMICRODUST POLLEN
OperationOn the main unit
Press the power button on the main unit to turn on theair purifier.
● Each time you press this button, the unit turns ONor OFF.
● Both the operation mode lamp and the monitorlamp must be ON.
● When you plug in the power cord, the monitorlamps blink for approximately two minutes whilethe sensors stabilize.
Viewing the monitor lampsThe lamps light up (four levels) depending on amount of air contaminants or odors present.
Dirty airClean airMIN
FAN SPEEDMAX
Using the remote controller
Press the power button on the remote controllerto turn on the air purifier. The operation is thesame as on the main unit.
ON OFF Press
PressHow to use the remote controller
The remote controller allows you to operate the unitfrom a remote place.
Aim the remote controller toward the main unit and press the switch. The maximum range ofoperation is 23 feet (7 m). Remote sensor
Remote controller
● Do not cover the remote sensor with cloths, etc.
● If the main unit does not respond properly to thesignals from the remote controller, replace withthe new batteries.
● Make sure the remote sensor and the remotecontroller are in sight of one another.
Remote controller operation may not be possible inthe following situations:● In areas where the unit is subjected to direct sunlight.
The infrared rays of the sunlight may effect the remotesensor on the unit
● In rooms with inverter lighting for lower power consumption.The noise from the inverter lighting may effect the remotesensor on the unit.
Howto
Use
TIMER FAN AUTO
NORMALPOLLENGUARDMINHOUR LOW MED HIGH MAX
POWERON/OFF
FAN AUTOAUTO FAN
MIN LOW MED HIGH MAX
NORMALPOLLENGUARD
AUTO FAN
PLASMA TIMER
POWER
beep
beep
beep
10
Changing the airflow
On the main unit Using the remote controllerYou can select between FAN (manual) and AUTO operation modes.
You can select from 5 airflow volumes or AUTO.
Pressone of the buttons
You can select the airflow volume from theremote controller. The operation is the same aswith the main unit.
Pressone of the buttons
FANYou can selectfrom 5 airflowvolumes.
● The airflow changes each timethe button is pressed, and thelamp of the chosen volume lightsup.
AUTOYou can selectfrom POLLENGUARD andNORMAL.
● Operation switches every timethe button is pressed, and theselected operation mode lamplights.
● Operation is automaticallyadjusted to the appropriateairflow volume according to theodor monitor, microdust monitor,and pollen monitor.
■ POLLEN GUARD● The sensor is set to
supersensitive to react to even theslightest traces of pollen.
● The fan speed is faster than theNORMAL operation for easierintake of large particles such aspollen, etc.
■ NORMAL● The level of air pollution in the
room is monitored using the odorand dust sensors, and theappropriate airflow volume isautomatically selected.
● When the air is clean, the fan willstop.
■ MIN or LOWWhen sleeping
■ HIGH or MAXWhen house cleaning
● The unit will return to the previously set mode even after turning the unit off.The unit will return to the previously set mode even when reinserting the power plug or after having a power failure.
TIMER FAN AUTO
NORMALPOLLENGUARDMINHOUR LOW MED HIGH MAX
POWERON/OFF
AUTO FAN
PLASMA TIMER
POWER
AUTO FAN
PLASMA TIMER
POWER
PLASMA
beep beeep
TIMER
TIMER
beep beep beepbeeep
HOURContinuousOperation(Lamp off)
Howto
Use
11
Plasma air deodorizationThe unit uses the odor sensor to monitor the level of air pollution, then automatically activates the Plasma to break up odor ingredients in the air.
Using the remote controllerYou can turn the Plasma deodorization function ON or OFF.
● Each time you press this button, the Plasma unitturns ON or OFF.
● Turn the Plasma deodorization lamp ON.● The unit will return to the previously set operation
mode when power is interrupted.
● Since the unit operates intermittently during thePlasma deodorization, a hissing noise may beheard, and the unit may also stop at times. Ifthe noise becomes irritating, turn off the featureby pressing the PLASMA button on the remotecontrol.
● When the Plasma deodorization lamp isblinking, turn the unit off, and clean the Plasmaunit.
To operate from the main unit, you can turn thePlasma deodorization ON or OFF using thefollowing procedure:● When the power is turned on, press and hold
the AUTO button, and press the POWERswitch.
Off TIMER operationOn the main unit
You can set the unit so that it turns off after runningfor a preset time. (1, 2, 4 hours)
Using the remote controller
You can also use the remote controller toset/deactivate the off TIMER. The operation is thesame as on the main unit.
● The selected Off TIMER lamp lights.● The Off TIMER lamp will display the remaining
operation time and will switch as time passes.
● The remaining operation time can be changed.
Changing the airflow
Plasm
a air deodorization/Off tim
er operation
ON OFF
Press
Press
Press
13
1
2
3
4
14
Direction of
airflow
12
Maintenance
Monthly cleaning
For the best performance from your unit, clean approximately once a month.
Both sides
Using the softnozzle brush of avacuum cleaner,
Cleaning the sensors Cleaning the HEPA filter
Odor sensor (control panel)
Remove dust usingthe nozzle of avacuum cleaner.
Remove surrounding dustusing the nozzle brush of avacuum cleaner.
Dust sensor surroundings
Cleaning the main unit
Intake grillRemove dustusing a nozzlebrush of avacuum cleaner.
For stubborn dirt, removethe intake grill, and washwith a soft sponge.Thoroughly dry beforereplacing.
Main unit
Dry-wipe witha soft cloth.
For stubborn dirt,wipe with a clothdampened withwater.
Press the grill release buttons oneach side, and remove the intake grill.
Remove the HEPA filter and clean.
Replace the HEPA filter.
remove dust by taking care notto tear the HEPA filter surface.
Do not wash. The filter cannotbe reused if washed or afterbecoming wet.
8
Replace the intake grill.
Hook the five tabs on the upperside of the intake grill, and pressin the lower side until the releasebuttons snap securely.
Replace the HEPA filter with the logo facing you and
arrows pointing away from you.
Cleaning Sensors, the HEPAfilter, and main unit
Cleaning the Plasma unit
Monthly
YearlyReplacing the filters
WARNINGBefore cleaning the unit,turn off the power andremove the power plug.Electrical shock and/or injurymay occur as a result.
1
4
5
2
3
1
3
2
13
Maintenance
WARNINGBefore cleaning the unit, turn off the power andremove the power plug.Electrical shock and/or injury may occur as a result.
Yearly cleaningClean at least once a year. Clean the Plasma unit if the Plasma deodorization lamp flashes.
Cleaning the dust sensor
Remove the cover by depressingthe cover spring.
Left side ofmain unit
Clean the sensor lenses.
Use a dry cotton swaband clean the two lenses.
Replace the cover.
Press the grill release buttons oneach side; remove the intake grill,and then remove the HEPA filter.
Remove the Plasma unit.
Cleaning the Plasma unit
Plasma unit
Do not pull by force. Malfunctionmay occur as a result.
Clean the Plasma unit.
Lightly flick off the tips. Using force maycause the Plasma unit to deform,resulting in malfunction of the unit.
Use a toothbrush, and lightly flickoff the tips of the electric poles.
Replace the Plasma unit.
Position the Plasma unit usingboth hands, and press in eachspring clip until you hear a click.
Push inthe lowersection.
Replace the HEPA filter and theintake grill.
Hold the springclips, and removeone side at a time.Pull the Plasma unittowards you toremove.
Monthly cleaning
Yearly cleaning
8
Please replace the HEPA filter and the activated charcoal filter with new filters when the color on the surface of the HEPA filter matches the color indicated above.
Available from Mitsubishi Electric www.plasmapure.com
REPLACE FILTERS
Reset Switch
1
2
3
4
5
6
Reset switch
Beep
14
Use a ball point pen,or a similar pointedobject, and pressuntil a beep is heard.
Maintenance (continued)
Replacing the filters
The filter replacement lamp notifies you of the replacement period of the HEPA filter and the activated charcoal filter. Replace both the HEPA filter and the activated charcoal filter at the same time.
Replacement period
Color of household dust
Color of cigarette ingredients
● The service life of the filters varies dependingon the usage environment, and conditions.
● The HEPA filter and the activated charcoal filtercannot be reused. Always replace old filterswith new filters.
● When smoking large amount of cigarettes, odormay adhere to the filter and main unit. In thiscase, clean the main unit, and replace the filters.
Separately sold part:
Replacement filter set(HEPA filter/activated charcoal filter)
Model MAPR-E837HFTCode no. 5D4 C06
To order parts, contact your dealer of purchaseor Mitsubishi Electric @ www.plasmapure.com
Remove the intake grill and theHEPA filter.
Remove the Plasma unit.
Replace the activated charcoalfilter.
Replace the Plasma unit andmount a new HEPA filter.
Insert the power plug and pressthe Reset Switch.
Set vertically.(There is no front or back.)
Replace the intake grill.
12~13
Although the replacement period depends onthe usage environment and conditions, thelamp will light after approximately 5 yearswhen using the unit on constant MIN fanspeed.(In the case of MAX, the lamp will light inapproximately 1/4 the time.)
● When the filter replacement lamp illuminates
● When the HEPA filter becomes dirty and thecolor is about the same as that indicated onthe label
Press the power switch and turn on the power.
Reinsert the power plug into the power outlet.
Clean the sensors.
Replace the HEPA filter and the activated charcoal filter.
Clean the sensors.
Replace the HEPA filter and the activated charcoal filter.
Clean the Plasma unit.
Reset the intake grill, the HEPA filter and the activated charcoal filter.
Replace with new batteries, or correctly set the batteries observing the proper polarity.
12~13
14
14
8
13
8
Symptom Cause Remedy
Symptom Cause
The odor monitor does not change even when an odor can be noticed
The sensitivity of the sensor differs depending on odor ingredients, and the monitor display may at times remain unchanged.
● The following symptoms are not malfunctions.
Should the problem persist after having checked the above list, stop using the unit, remove the power plug and contact your dealer of purchase or Mitsubishi Electric.
There is no air intake
Odor and smoke are not completely removed
Is the fan level lamp on?(Is the power on?)
Is the power plug securely inserted into the power outlet?
Are the sensors dusty?
During the Plasma deodorization, you may hear a small hissing noise or notice an ozone smell.(The level of noise and degree of the smell of ozone will vary depending on the environment. The generated ozone is of low concentration and is harmless to the body.)
The monitors do not change much(Odor monitor, microdust monitor and pollen monitor)
Is the room too large?Use the unit within the range of the applicable floor area.
Checking monitor operation:● Rub tissue paper in front
of the main unit to discharge dust.
● Blow cigarette smoke.If there is a large volume of dust or odor, it may take some time for the air to become clean.
The monitor lamp flashes The monitor lamp will flash until the sensors become stable, even if the power is turned on immediately after inserting the power plug.
The monitor lamp flashes even when the room is clean
The sensor may at times respond to a breeze from air conditioners within the room, and gases that are unnoticeable to the human smell.
Is the unit operating in AUTO (NORMAL) mode?The unit will stop operation when the air is clean.
Are the sensors dusty?
Fan noise and vibration are louder than before
Plasma deodorization lamp flashes
There is an abnormal electrical discharge.
Is the activated charcoal filter still wrapped in plastic?
One of the following lamps flash:FAN/POLLEN GUARD/NORMAL
Are the intake grill, the HEPA filter and the activated charcoal filter properly set?
The remote controller does not work
Main unit vibrates heavily
Little monitor response
Is the unit installed on an unstable or unlevel surface? Install on a level and stable surface.
Is the HEPA filter or the activated charcoal filter dirty?
12~13
Is the HEPA filter or the activated charcoal filter dirty?
Remove the plastic and replace.
Have the batteries been completely depleted or are the and of the batteries set correctly?
The air fan does not turn, or there is no air discharge
A small hissing noise is heard, or there is a smell of ozone during the Plasma deodorization
Trouble-shooting
15
Maintenance
Troubleshooting
Replacing the filters
Troubleshooting
T946Z023H01 00/11PPIMA11/00-04K
Power consumption
Airflow volume
Room size
Weight
Dimension(H×W×D)
Power cord length
Safety devices
Accessories
MA-EF503HS-UAC120V 60Hz
233 Sq.FT 155 Sq.FT 13 ft × 18 ft 11 ft × 14 ft
17.1lbs (7.6 kg)
15-3/4" × 22-7/32" × 7-7/8"(400mm × 564mm × 200mm)
8.2 ft (2.5m)
MAX
HIGH
MED
LOW
MIN
MAX
HIGH
MED
LOW
MIN
36W
26W
19W
17W
16W
106 CFM
90 CFM
65 CFM
46 CFM
34 CFM
66W
28W
19W
17W
16W
160 CFM
102 CFM
65 CFM
46 CFM
34 CFM
MIT
SU
BIS
HI E
LEC
TR
IC A
IR P
UR
IFIE
R M
A-E
F503H
S-U
• MA
-EF
303HS
-U
Model
Power supply
Current fuse (2A), motor overheat protection device (operational temp: 212°F (100°C)), abnormal electric discharge protection device
Remote controller (type AA battery × 2)
MA-EF303HS-U
Specifications
For more information, visitwww.plasmapure.comor call 1-866-475-2762