+ All Categories
Home > Documents > PLC2 - McNaughton-McKay...COMMISSIONING - PLC2 Cost: $1,695.00 per student for this 3-Day Course...

PLC2 - McNaughton-McKay...COMMISSIONING - PLC2 Cost: $1,695.00 per student for this 3-Day Course...

Date post: 19-Jul-2020
Category:
Upload: others
View: 0 times
Download: 0 times
Share this document with a friend
2
INSTRUCTOR LED TRAINING CONTINUATION OF PLC WIRING AND COMMISSIONING - PLC2 Overview: At the completion of this course, the participants will have the ability to “talk through” and debug/troubleshoot the PLC’s ladder logic using the Logix5000 soſtware in order to locate a “real,” faulty input or output device, replace it, and get the process back up and running. The suggested prerequisite for this course is the “Fundametnals of PLC Wiring and Commissioning - PLC1” course or prior experience. The participant will begin their training by wiring the actual input and output (I/O) devices such as photo-electric sensors, inductive proximity and selector switches, pushbuttons, and outputs such as contactors, indicator lamps, etc. to the PLC’s input/output module. This course serves as a solid foundation for those planning on taking Rockwell Automation Studio 5000/Control Logix courses. The participants actually wire their own PLC trainer! A review of the PLC’s instruction-set including “real” and “simulated” I/O, troubleshooting tools that “toggle” and “force” I/O, Timer (TON, TOF, RTO) and Counter (CTU, CTD) circuits, special functions such as One-Shot (ONS), First Scan (S:FS), Set Bit if Zero/Negative (S:Z, S:N), Comparison instructions such as EQU, NEQ, GRT, LES, GEQ, LEQ, LIM, etc.,Math instructions including ADD, SUB, MUL, and DIV. These instructions were initially covered in the PLC Wiring and Commissioning - PLC1 course. Ladder logic utilizing Jump (JMP) and Master Control Reset (MCR) instructions will be introduced along with the Jump to Subroutine (JSR) instruction. To effectively troubleshoot a Logix5000 PLC-based system, one must know how the PLC’s Memory Structure is allocated throughout the ladder logic program. One and two dimension arrays are key areas to understand. We will accomplish this by troubleshooting ladder logic that includes instructions such as Fill File (FLL), Copy File (COP), and Average File (AVE). Other instructions include Bit Shiſt Right/Leſt (BSR)/(BSL), First-in-Fist-Out (FIFO) Load/Unload (LFL/LFU), and Masked Move (MVM). Examples of Sequencer circuits involving the Sequencer’s various tables such as Array, Mask, and Output tables will be covered in detail. Understanding how Indirect Addressing and its associated memory arrays are applied in a ladder logic program is critical in troubleshooting a PLC-based system. One of the most powerful tools found in the Logix5000 soſtware is the Add-On Instruction. In order to troubleshoot these instructions, one must know how to interpret their Definition Table, which consists of various “tagged” parameters and the ladder logic used to develop the Add-On Instruction. Therefore, each participant will create and troubleshoot several Add-On Instructions. Numerous hands-on labs utilizing troubleshooting skills are included in all of the above subject matter in order to reinforce the lecture material. Cost: $1,695.00 per student for this 3-Day Course Receive a 10% discount for 3-5 students; or 15% discount for 6 or more students Professional Development Hours (PDH): 21 at completion For more information and complete upcoming training schedule visit us : www.mc-mc.com/training
Transcript
Page 1: PLC2 - McNaughton-McKay...COMMISSIONING - PLC2 Cost: $1,695.00 per student for this 3-Day Course Receive a 10% discount for 3-5 students; or 15% discount for 6 or more students Professional

INSTRUCTOR LED TRAININGCONTINUATION OF PLC WIRING AND

COMMISSIONING - PLC2Overview: At the completion of this course, the participants will have the ability to “talk through” and debug/troubleshoot the PLC’s ladder logic using the Logix5000 software in order to locate a “real,” faulty input or output device, replace it, and get the process back up and running. The suggested prerequisite for this course is the “Fundametnals of PLC Wiring and Commissioning - PLC1” course or prior experience.

The participant will begin their training by wiring the actual input and output (I/O) devices such as photo-electric sensors, inductive proximity and selector switches, pushbuttons, and outputs such as contactors, indicator lamps, etc. to the PLC’s input/output module. This course serves as a solid foundation for those planning on taking Rockwell Automation Studio 5000/Control Logix courses.

The participants actually wire their own PLC trainer!

• A review of the PLC’s instruction-set including “real” and “simulated”I/O, troubleshooting tools that “toggle” and “force” I/O, Timer(TON, TOF, RTO) and Counter (CTU, CTD) circuits, special functionssuch as One-Shot (ONS), First Scan (S:FS), Set Bit if Zero/Negative(S:Z, S:N), Comparison instructions such as EQU, NEQ, GRT, LES, GEQ,LEQ, LIM, etc.,Math instructions including ADD, SUB, MUL, and DIV.These instructions were initially covered in the PLC Wiring and Commissioning - PLC1 course.

• Ladder logic utilizing Jump (JMP) and Master Control Reset (MCR) instructions will be introduced along withthe Jump to Subroutine (JSR) instruction.

• To effectively troubleshoot a Logix5000 PLC-based system, one must know how the PLC’s Memory Structureis allocated throughout the ladder logic program. One and two dimensionarrays are key areas to understand. We will accomplish this by troubleshooting ladder logic that includesinstructions such as Fill File (FLL), Copy File (COP), and Average File (AVE). Other instructions include Bit ShiftRight/Left (BSR)/(BSL), First-in-Fist-Out (FIFO) Load/Unload (LFL/LFU), and Masked Move (MVM).

• Examples of Sequencer circuits involving the Sequencer’s various tables such as Array, Mask, and Outputtables will be covered in detail.

• Understanding how Indirect Addressing and its associated memory arrays are applied in a ladder logicprogram is critical in troubleshooting a PLC-based system.

• One of the most powerful tools found in the Logix5000 software is the Add-On Instruction. In order totroubleshoot these instructions, one must know how to interpret their Definition Table, which consists ofvarious “tagged” parameters and the ladder logic used to develop the Add-On Instruction. Therefore, eachparticipant will create and troubleshoot several Add-On Instructions.

• Numerous hands-on labs utilizing troubleshooting skills are included in all of the above subject matterin order to reinforce the lecture material.

Cost: $1,695.00 per student for this 3-Day CourseReceive a 10% discount for 3-5 students; or 15% discount for 6 or more students

Professional Development Hours (PDH): 21 at completion

For more information and complete upcoming training schedule visit us : www.mc-mc.com/training

Page 2: PLC2 - McNaughton-McKay...COMMISSIONING - PLC2 Cost: $1,695.00 per student for this 3-Day Course Receive a 10% discount for 3-5 students; or 15% discount for 6 or more students Professional

INSTRUCTOR LED TRAININGCONTINUATION OF PLC WIRING AND

COMMISSIONING - PLC2

Cost: $1,695.00 per student for this 3-Day CourseReceive a 10% discount for 3-5 students; or 15% discount for 6 or more students

Professional Development Hours (PDH): 21 at completion

UPCOMING COURSE SCHEDULE:November 8 - 10, 2017 Madison Heights, Michigan

REGISTRATION INFORMATION:Register online for this training at: https://www.mc-mc.com/training

Or Contact: Vicki Isom, Training and Special Services Coordinator Email: [email protected] Phone: 248-582-2485

Instructor: Bob Draime, Star Electrical Training


Recommended