Plots from RCNP UCN Run
(April 20-25, 2010)
EDM Set-up SchematicH0
(RF) H1
Spin Flipper
RF Coil
Spherical Coil
Cell Valve
EDM Cell
Magnetized Foil
Rotary Valve(2-way)
UCN Valve
UCN Detector
Spin Precessor
UCN Storage Time in EDM Cell
UCN Yield vs Delay-time (before opening cell valve)
Spin-Flipper Optimization
(Find optimal amplitude for Spin Flipper B-field)
Flipping Asymmetry vs B-field Amplitude
Polarization Lifetimes (T1)
“Flipping Asymmetry” as a function of Holding Time
UCN-Yield Time Spectra (-100mG)
Polarization Lifetimes (T1)
“Flipping Asymmetry” as a function of Holding Time
UCN-Yield Time Spectra (-10mG)
Scan for Resonant Frequency at -100 mG
UCN-Yield versus RF Frequency of H1 field
“Single Shot” pulse
Scan for Resonant Frequency at -100 mG
UCN-Yield versus RF Frequency of H1 field
Blue: H1 ~ 1 mGRed: H1 ~ 10 mG
“Single Shot” pulse
Optimizing Amplitude (H1) for RF coil
UCN-Yield versus Amplitude of H1 Field
“Single Shot” pulse
Ramsey Resonance Scan (-100 mG, Tc=1s)
Ramsey Frequency Scan (H0~ -100mG, TC~1s, H1~1mG, ~100ms)
Aside#1: Definition of ParametersRamsey Frequency Scan
H0 Holding Field (vertical)H1 Amplitude of RF Field (horizontal) Duration of RF pulse [want = H1]TC Time between ( RF pulses
TCH1
Aside#2: “Visibility”Ramsey Frequency Scan
“Visibility” ~ Ampl. Of Fringe/Ampl of Envelope (AF / AE )
Ideally (AF / AE ) ~ 1
AFAE
Ramsey Resonance Scan (-100 mG, Tc=1s)
Ramsey Frequency Scan (H0~ -100mG, TC~1s, H1~1mG, ~100ms)
Ramsey Resonance Scan (-100 mG, Tc=5s)
Ramsey Frequency Scan (H0~ -100mG, TC~5s, H1~1mG, ~100ms)
Ramsey Resonance Scan (-100 mG, Tc=10s)
Ramsey Frequency Scan (H0~ -100mG, TC~10s, H1~1mG, ~100ms)
Visibility Study of Ramsey Scans
Ramsey Oscillation Amplitude vs TC (Precession Time)
Ramsey Resonance Scan (-100 mG, Tc=1s)H1 is 10 times smaller
Ramsey Frequency Scan (H0~ -100mG, TC~1s, H1~0.1mG, ~1s)
Ramsey Resonance Scan (-100 mG, Tc=1s)H1 10 times smaller
Ramsey Frequency Scan (H0~ -100mG, TC~1s, H1~0.1mG, ~1s)
Scan for Resonant Frequency at -50 mG
UCN-Yield versus RF Frequency of H1 field
“Single Shot” pulse
Scan for Resonant Frequency at -10 mG
UCN-Yield versus RF Frequency of H1 field
“Single Shot” pulse
Scan for Resonant Frequency at +10 mG
UCN-Yield versus RF Frequency of H1 field
“Single Shot” pulse
Polarization Lifetime (T1) at low H0 Fields
Flipping Asymmetry vs Holding Time (at 10mG)
Scan for Resonant Frequency at +50 mG
UCN-Yield versus RF Frequency of H1 field
“Single Shot” pulse
Scan for Resonant Frequency at -20 mG
UCN-Yield versus RF Frequency of H1 field
“Single Shot” pulse
Flipping Asymmetry vs H0 (Main Holding Field)
Scan for Optimal H0 (where T1 is still reasonable)
Flipping Asymmetry vs H0 Field
-20 mG still looks OK
(B/z) Trim Coil study
TC vs Trim Current
Ramsey Frequency Scan (Trim~0.035A, TC~1s)
(B/z) Trim Coil study
TC vs Trim Current
Ramsey Frequency Scan (Trim~0.035A, TC~10s)
(B/z) Trim Coil study
TC vs Trim Current
Ramsey Frequency Scan (Trim~0.035A, TC~3s)
(B/z) Trim Coil study
Trim Current comparison TC ~3s
Ramsey Frequency Scan (TC~3s)
Better Results with Trim Coil OFF !!
Ramsey Resonance Scan (-20 mG, Tc=3s)
Ramsey Frequency Scan (H0~ -20mG, TC~3s, H1~0.33mG, ~300ms)
Ramsey Resonance Scan (-20 mG, Tc=10s)
Ramsey Frequency Scan (H0~ -20mG, TC~10s, H1~0.1mG, ~1s)
Ramsey Resonance Scan (-20 mG, Tc=20s)
Ramsey Frequency Scan (H0~ -20mG, TC~20s, H1~0.05mG, ~2s)
Optimizing Amplitude (H1) for RF coil
UCN-Yield versus Amplitude of H1 Field
Ramsey Resonance Scan (-20 mG, Tc=30s)
Ramsey Frequency Scan (H0~ -20mG, TC~30s, H1~0.1mG, ~1s)
Ramsey Resonance Scan (-20 mG, Tc=30s)
Ramsey Frequency Scan (H0~ -20mG, TC~30s, H1~0.1mG, ~1s)
“ZOOMED IN”
Ramsey Resonance Scan (-20 mG, Tc=50s)
Ramsey Freq. Scan (H0~ -20mG, TC~50s, H1~0.1mG, ~1s)
“Zoomed In”(any fringes?)(BG subtraction?)
“Zoomed Out”(baseline, amplitude?)
Ramsey Resonance Scan (-20 mG, Tc=40s)
Ramsey Freq. Scan (H0~ -20mG, TC~40s, H1~0.1mG, ~1s)
“Zoomed In”(any fringes?)(BG subtraction?)
“Zoomed Out”(baseline, amplitude?)
Polarization Lifetime (T1) at H0~ -20mG
Flipping Asymmetry vs Holding Time
These points should be decreasing, if anything.(BG subtraction needed? Also, Stats getting worse as Holding Time UCN Storage Time)