Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
SHEET
REFERENCE
NUMBER:
2
9:2
1:1
1 A
M7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-0010.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
PLUGGED PIPE/OUTLET
CONCENTRIC REDUCER
ECCENTRIC REDUCER
CAPPED PIPE/OUTLET
UNION
P/TRV
U
PRESSURE/TEMPERATURE RELIEF VALVE
HB
SOV
FLEXIBLE PIPE CONNECTOR
HOSE BIBB / WALL HYDRANT
THERMOMETER
CHECK VALVECV
PRV PRESSURE REDUCING VALVE
TOP CONNECTION
BOTTOM CONNECTION
CO OR WCO CLEANOUT OR WALL CLEANOUT
FCO FLOOR CLEANOUT
COTG CLEANOUT TO GRADE
SHUT-OFF VALVE OR ISOLATION VALVE
C.
KO
RP
AS
H
154
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
GE
NE
RAL N
OTES, S
YM
BO
LS,
AN
D
AB
BR
EVIA
TIO
NS
PLU
MBIN
G
P-0010
07-2
8-1
1
M.
BE
TZ
LC
AR
C_P-0
010.d
gn
SYMBOL ABBREVIATION DESCRIPTION SYMBOL ABBREVIATION DESCRIPTION
ANCHOR
WATER HAMMER ARRESTER
FLUID FLOW DIRECTION
WHA
GAS COCK
DOMESTIC HOT WATER RETURN LINEHWR
DOMESTIC HOT WATER SUPPLYHW
CW DOMESTIC COLD WATER SUPPLY
PLUMBING ABBREVIATIONS PLUMBING LEGEND AND SYMBOLS
CBV CALIBRATED BALANCE VALVE
PIPE UP OR DOWN BASED ON SYSTEM
PIPE ELBOW UP OR DOWN BASED ON SYSTEM FLOW
VENT
SANITARY SEWER/WASTE OR INDUSTRIAL WASTE OR GREASE WASTE BELOW FLOOR OR GRADE
EXPANSION JOINT
FLOOR DRAIN OR SHOWER DRAIN
FLOOR SINK
AND APPLICABLE LOCAL CODES.
AND INVERT ELEVATIONS PRIOR TO COMMENCEMENT OF WORK.
4. FURNISH MATERIALS, CUTTING, PATCHING, ADAPTING AND OTHER INCIDENTAL WORK, TOGETHER WITH SUCH
TEMPORARY CONNECTIONS AS MAY BE REQUIRED.
5. ROUTE HORIZONTAL VENT PIPING ABOVE CEILING AND ROUTE HORIZONTAL SANITARY PIPING BELOW SLAB
UNLESS OTHERWISE NOTED.
1. PROVIDE LABOR AND MATERIALS TO DELIVER COMPLETE AND PROPERLY FUNCTIONING PLUMBING SYSTEMS.
FOR LOCATION OF EXPANSION JOINTS BEFORE COMMENCEMENT OF WORK.
10. PROVIDE FLEX PIPING AT STRUCTURAL BUILDING EXPANSION JOINTS. SEE ARCH. AND STRUCTURAL DRAWINGS
GENERAL NOTES
NOTE: NOT ALL ABBREVIATIONS AND
SYMBOLS SHOWN HEREIN ARE UTILIZED.
PROVIDE BOLTING AND WELDING OF SUPPORTS PER CONTRACT STRUCTURAL SPECIFICATIONS.
SUBMIT SHOP DRAWINGS FOR GOVERNMENT APPROVAL.
A
FULL LOAD AMPSFLA
D
ELEC
ENCL
ELEV, EL
EFF
F
FCO
EXH
FT
DEGREE FAHRENHEIT
FLOOR CLEANOUT
ELEVATION
ELECTRICAL
ENCLOSURE
EFFICIENCY
EXHAUST
DESIG
dB
DWH
DS
DWG(S)
DIM
DN
DISC
E
EA
ECC
D
DOWNSPOUT
ECCENTRIC
DOMESTIC WATER HEATER
EACH
DRAWING(S)
DESIGNATION
DIMENSION
DISCONNECT
DIAMETER
DOWN
DEPTH
DECIBEL
RECIRC
SHT MTL
Q
C
C L
B
LB(S) OR #
LF
SQ
STD
STL
SS
SUSP
SURF
SP
SPEC
SD
SECT
SCAQMD
SHT
SIM
SF
RLA
S
RM
RPM
REQD
REV
REINF
RE:
RD
R
QTY
PV
PVC
PSV
PSIG
DISCHARGEDISCH
EXTERNALEXT
EXHAUST FANEF
RTU
FAN COILFC
STRUC
EER ENERGY EFFICIENCY RATIO
ET EXPANSION TANK
FD
FLOOR SINKFS
SEER
SOV
SYM
DEG
(E) EXISTING
EXPANSION JOINTEXP. JOINT
FLOORFLR
FEET PER MINUTEFPM
SV
SMACNA
FOOT, FEET
S
AMERICAN SOCIETY OF HEATING,
REFRIGERATING AND AIR CONDITIONING
ENGINEERS
SHEET METAL AND AIR CONDITIONING
CONTRACTORS NATIONAL ASSOCIATION
POUND(S)
LINEAR FEET
SUPPLY VALVE
SUSPEND
SURFACE
STRUCTURAL
STEEL
STANDARD
STAINLESS STEEL, SERVICE SINK
SQUARE
SPECIFICATION
SHUT-OFF VALVE
SHEET METAL
SIMILAR
SHEET
SQUARE FEET
SEASONAL ENERGY EFFICIENCY RATIO
SECTION
STORM DRAIN
SOUTH COAST AIR QUALITY
MANAGEMENT DISTRICT
ROOF TOP UNIT
REVOLUTIONS PER MINUTE
ROOM
RUNNING LOAD AMPERES
REVISION, REVISE
REQUIRED
REINFORCING
RECIRCULATE
REFERENCE, REFER
ROOF DRAIN
QUANTITY
POLYVINYL CHLORIDE
PLUG VALVE
PRESSURE SAFETY VALVE
POUNDS PER SQUARE INCH GAUGE
DFU DRAINAGE FIXTURE UNIT
ABOVE
AIR COOLED CONDENSING UNIT
ADJUSTABLE
ACCESS DOOR
ABOVE FINISH FLOOR
AIR HANDLING UNIT
ALUMINUM
AMPERE(S)
ACCESS PANEL
APPROXIMATE
ARCHITECT, ARCHITECTURAL
AIR SEPARATOR
AUXILIARY
AIR VENTAV
AUX
ASHRAE
AS
ARCH
APPROX
AP
AMP
AL
AHU
AFF
AD
ADJ
ACCU
AC
ABV
BOILER
BLOW-DOWN
BELOW
BELOW FINISH FLOOR
BUTTERFLY VALVE
BRAKE HORSEPOWER
BREAKER
BUILDING
BOTTOM OF DUCT
BOTTOM OF PIPE
BOTTOM OF STEEL
BRITISH THERMAL UNIT
BALL VALVEBV
BTU
BOS
BOP, B.O.P.
BOD
BLDG
BKR
BHP
BFV
BFF
BEL
BD
B
CAPACITY
CONDENSATE DRAIN
CUBIC FEET PER HOUR
CUBIC FEET PER MINUTE
CHILLER
CAST IRON
CIRCULATING
CENTERLINE
CEILING
CONCRETE MASONRY UNIT
CLEANOUT
COLUMN
CONNECT, CONNECTION
CLEANOUT TO GRADE
CHLORINATED POLYVINYL CHLORIDE
CIRCULATING PUMP
CONDENSATE RECEIVER
CONDENSING UNIT
DEGREES CELSIUS
CW
CU
CR
CPVC
CP
COTG
CONN
COL
CO
CMU
CLG
CIRC
CI
CH
CFM
CFH
CD
CAP.
BRITISH THERMAL UNIT PER HOURBTUH
CALIBRATED BALANCE VALVECBV
AMERICAN WITH DISABILITIES ACTADA
ABOVE FINISH GRADEAFG
ACRYLONITRILE BUTADIENE STYRENEABS
BACKFLOW PREVENTERBFP
CONTINUE, CONTINUATIONCONT
COMPUTER ROOM AIR CONDITIONINGCRAC
ELECTRIC WATER COOLEREWC
FINISHFIN
CUBIC FEETCF
CONDENSATECOND
LOC LOCATION
FINISH FLOOR ELEVATIONFFE, F.F.E.,
SLOPE AT PERCENTAGE SHOWN
CONDENSATE DRAIN PUMPCDP
FINISH GRADE ELEVATIONFGE, F.G.E.,
FIN FLR ELEV
FIN GRADE ELEV
CONTRACTORCONTR
DISTANCE
FWD FOOD WASTE DISPOSER
ABOVE FINISH SURFACEAFS
BACK WATER VALVEBWV
(R) RELOCATED
EWS
SYMBOL
P
OF
WR
OPNG
OH
O
NIC
NOM
NO
OC
OD
XFMR
X
WC
WPD
W
W/O
W/
W
MTD
MV
NC
N/A
NEMA
N
MBH
MAX
MFR
MECH
VERT
VTR
VEL
VV
VAC
U/G
U/F
UL
UPS
UNO
U/S
U
L
J-BOX
KW
KWH
K
J
TTDH
THRU
TP
IN WG
IN
I.E., IE
ID
I
HTG
HTR
HVAC
HOA
HP
HORIZ
HW
GALV
GL
HD
GPM
GPH
HC
H
GAL
GA
PLC
PSI
PSF
PLBG
PSIA
WP
PRV
VFD
POC
POD
IN w.c.
MS
H
HWR
HB
NO.
OPER
PRS
P
PS
TEMP
WT
N.T.S., NTS
PH
PCD
PD
PRESS
U/C
UTR
G
OSHA
WHA
WAP
WCO
VBF
OCCUPATIONAL SAFETY AND HEALTH
ADMINISTRATION
HEATING, VENTILATION AND
AIR CONDITIONING
GAUGE, GAGE
GALLON
GALVANIZED
GALLONS PER HOUR
GALLONS PER MINUTE
HEIGHT
HOSE BIBB
HEATING COIL
HAND-OFF-AUTOMATIC
HORIZONTAL
HORSEPOWER
HEATING
HEATER
INSIDE DIAMETER
INVERT ELEVATION
INCH
INCHES WATER GAUGE
INCHES OF WATER COLUMN
JUNCTION BOX
KILOWATT
KILOWATT-HOUR
MAXIMUM
1000 BTU PER HOUR
MECHANICAL
MANUFACTURER
MIXING VALVE
MOUNTED
MOP SINK
NOT APPLICABLE
NORMALLY CLOSED
NATIONAL ELECTRICAL
MANUFACTURER’S ASSOCIATION
NOT IN CONTRACT
NORMALLY OPEN
NUMBER
NOMINAL
NOT TO SCALE
ON CENTER
OVERFLOW
OVERHEAD
OPENING
OPERATING
TRANSFORMER
WATER HAMMER ARRESTER
WEIGHT
WATER RISER
WEATHER PROOF
WATER PRESSURE DROP
WALL CLEANOUT
WATER CLOSET
WALL ACCESS PANEL
WITHOUT
WITH
WASTE
VENT THROUGH ROOF
VARIABLE FREQUENCY DRIVE
VERTICAL
VELOCITY
VENT BELOW FLOOR
VOLTAGE ALTERNATING CURRENT
UNINTERRUPTIBLE POWER SUPPLY
UNLESS NOTED OTHERWISE
UNDERWRITERS LABORATORIES,
INC.
UP THROUGH ROOF
UNDER SLAB
UNDERGROUND
UNDER FLOOR
UNDER CUT
THROUGH
TOTAL DYNAMIC HEAD
TEMPERATURE
POUNDS PER SQUARE INCH ABSOLUTE
POUNDS PER SQUARE INCH
POUNDS PER SQUARE FOOT
PRESSURE SWITCH
PRESSURE REDUCING VALVE
PRESSURE REDUCING STATION
PRESSURE
POINT OF DISCONNECT
POINT OF CONNECTION
PUMP LEVEL CONTROL(S)
PLUMBING
PHASE
PRESSURE DROP, PERIMETER DRAIN
PUMP CONDENSATE DRAIN
PUMP
WSFU WATER SUPPLY FIXTURE UNIT
w.c. WATER COLUMN
VOR VALVE ON RISER
HZ HERTZ
ICW INDUSTRIAL COLD WATER
MPG MEDIUM PRESSURE GAS
TYP TYPICAL
GPR GAS PRESSURE REGULATOR
MIN MINIMUM
TMV THERMOSTATIC MIXING VALVE
IT INFORMATION TECHNOLOGY
TOP, T.O.P. TOP OF PIPE
PNL PANEL
G
M
LAVATORY
CA COMPRESSED AIR
AIR COMPRESSOR
ATF AUTOMATIC TRANSMISSION FLUID
DOMESTIC COLD WATER
DIST
EMERGENCY SHOWER AND EYE WASH
EQUIP EQUIPMENT
EQ EQUAL
FCW FILTERED COLD WATER
FLOOR DRAIN
FP FIRE PROTECTION
NATURAL GAS (LOW PRESSURE)
GRID LINE
GM GAS METER
GREASE WASTE (KITCHEN)
GRS GREASE
GW
HEAD
DOMESTIC HOT WATER (SUPPLY)
DOMESTIC HOT WATER RETURN
IW INDUSTRIAL WASTE
L
LO LUBRICATING OIL
OUTSIDE DIAMETER
SOIL (SANITARY SEWER)
SHD
SH SHOWER
SHOWER DRAIN
SUMP PUMP
UFC UNIFIED FACILITIES CRITERIA
VENT
VLV VALVE
WASH FOUNTAINWF
SPECIALTIES LOCATED INSIDE CHASES, BEHIND WALLS OR ABOVE INACCESSIBLE CEILINGS.
6. PROVIDE PIPE PENETRATIONS THROUGH FLOOR SLAB AND WALLS WITH PIPE SLEEVES.
AB ASSEMBLY BILL
AD AREA DRAIN
ARC ARMY RESERVE CENTER
DEGREE(S)
EQV EARTHQUAKE VALVE
OMS
TRAP PRIMER OR TRAP PRIMING
USB UNIT STORAGE BUILDING
ORGANIZATIONAL MAINTENANCE SHOP
RWH RAIN WATER HARVESTING
11. SITE ELEVATION IS OVER 4,000 FEET ABOVE SEE LEVEL. ALL EQUIPMENT PERFORMANCE SHALL CONFORM TO
LOCAL CONDITIONS.
8. PROVIDE SECONDARY STRUCTURAL STEEL MEMBERS AS REQUIRED FOR PIPING AND EQUIPMENT SUPPORTS.
7. PROVIDE ACCESS PANELS FOR VALVES, WATER HAMMER ARRESTERS AND OTHER PLUMBING
3. COORDINATE PLUMBING WORK WITH SITE CONDITIONS AND WORK OF OTHER TRADES. VERIFY SLOPES
EDGE AND AIR INTAKES.
2. INSTALL PLUMBING WORK IN ACCORDANCE WITH CONTRACT SPECIFICATIONS, IPC 2006, UFC REQUIREMENTS,
BOI BID OPTION ITEM
RW RAIN WATER
SK SINK
SW COLD WATER (SOFT)
WS WATER SOFTENER
CDF CONDENSATE DRAIN FUNNEL
9. VENT ROOF PENETRATIONS SHALL BE A MINIMUM OF 10 FEET HORIZONTALLY AWAY FROM THE ROOF
PROVIDE FIRE STOPPING FOR PIPING CROSSING FIRE-RATED WALL. REFER TO ARCHITECTURAL DRAWINGS FOR FIRE RATED WALL LOCATIONS.
12.
13.
TW TEPID WATER
PROVIDE SEISMIC SEPARATION FOR PIPING CROSSING BUILDING SEISMIC JOINT. REFER TO STRUCTURAL DRAWINGS FOR BUILDING SEISMIC JOINT LOCATIONS.
WM WATER METER
1
2
3
4
5
6
2"
3"FCO
3"
FS-1
FS-1FS-1
3"
3"
3" 3"
3"
4"
FS-12"
4"
4"FCO
COTG
4"
3"
2"
2"
S=2%
3"
FS-1
3"
1
1
12
3
2
2 2
2
2 2
24
COTG
4
FS-1
4"
2
S=2
%
1.
2.
3.
F.F.E. = 100’-0" (4404.50’)
5
2"
2"
S=2%
4"FCO I.E.97’-9"
2"1
4"1
FS-1(TYP)
FS-1(TYP)
W DN THRU FLOOR
2" V UP THRU FLOOR
3"V UP THRU FLOOR
POC TO 6" WASTE I.E. 96’-0" (4400.50) LATERAL WITH 4"x6" INCREASER, FOR CONT SEE CIVIL DWG CU-124
POC TO 3"V I.E. 97’-0" (4401.50’) LATERAL, FOR CONT. SEE CIVIL CU-124
4"W UNDER FLOOR, PROVIDE SLEEVE PER B2/ S-5010
6
EWC-1
REFER TO ARCHITECTURAL DRAWINGS FOR FINISH FLOOR AND CEILING ELEVATIONS.
REFER TO CIVIL DRAWING CG-119 FOR FINISH GRADING ELEVATIONS OUTSIDE THE BUILDING.
REFER TO STRUCTURAL DRAWING S-111A FOR FOUNDATION LOCATIONS.
4" FCO I.E. 98’-0"
MA
TC
H
LIN
E
SE
E
SH
EE
T
P-112
A
MA
TC
H
LIN
E
SE
E
SH
EE
T
P-112
A
SCALE :1/8"=1’-0"A1
N
5’-0"
5’-0"
37’-10"
65’-1"
61’-4"
0 16’4’ 8’
ARC-FIRST FLOOR PLAN-SECTOR ONE - UNDER FLOOR
C.
KO
RP
AS
H
155
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
UN
DE
R FLO
OR
AR
C-FIR
ST FLO
OR PLA
N-SE
CT
OR
ON
E -
PLU
MBIN
G
P-111A
07-2
8-1
1
M.
BE
TZ
LC
AR
C_P-1
11
A.d
gn
KEY NOTES
GENERAL NOTES
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
N
SHEET
REFERENCE
NUMBER:
2
9:2
2:4
9
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-111A.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
KEY PLAN
ARC
OMS
A2
A1
B
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
1 2 3 4
J
A101
LOBBY
A105A
WEAPONS
SIMULATOR RM.
A107
UNIT
STORAGE
A108
ARMS
VAULT
A109
ARMORER
WORK AREA
A110
STAGING
AREA
A111
SUPPLY
OFFICE
A102
ASSEMBLY
A103C
JANITOR
A103B
OFFICE
A103A
KITCHEN
A106
STORAGE
A104
TABLE AND
CHAIR STORAGE
A105B
CONTROL
ROOM
F
P
C
B
A
Q
K
M
1
2
3
4
5
6
7
1
1
1
5
32
2
1
2
1
2
1
1
2
2
2
2
2
1
2
6
6
6
6
2
66
2
2
6
2
1.
2.
3.
REFER TO ARCHITECTURAL DRAWINGS FOR FINISH FLOOR AND CEILING ELEVATIONS.
REFER TO CIVIL DRAWING CG-119 FOR FINISH GRADING ELEVATIONS OUTSIDE THE BUILDING.
REFER TO STRUCTURAL DRAWING S-112A FOR FOUNDATION LOCATIONS.
2
2
2
4
1
W OR S DOWN THRU FLOOR
V UP THRU FLOOR
3"CW (44.61 PSI) UP THRU FLOOR
2-1/2" ICW UP THRU FLOOR
2 1/2" ICW BOP 96’-0" (4400.50’)CAP FOR FUTURE CONNECTION
1/2" TP DOWN THRU FLOOR TO FD
WATER METER WM-1 IN METER VAULT
7
S=2%
MA
TC
H
LIN
E
SE
E
SH
EE
T
P-111A
MA
TC
H
LIN
E
SE
E
SH
EE
T
P-111A
N
SCALE :1/8"=1’-0"A1
2"
4"
2"
4" 4"
2"
SHD-1
SHD-1
SHD-1
SHD-1
SHD-1
SHD-1
SHD-1
SHD-1
SHD-1
SHD-1
SHD-1
SHD-1
2"
FD-1
FD-1
FD-1
FS-1
2"
2"
2"FD-1
2"
4"
4"
2"
FD-1
FD-1
FD-1
2"2"
2"
2"
2"
2"
2"
3"
2"
ARC-FIRST FLOOR PLAN-SECTOR TWO - UNDER FLOOR
4" COTG
COTG
F.F.E. = 100’ - 0" (4404.50’)
4" FCO I.E. 98’-6"
COTG
FCO
2" (TYP OF 4)
5’-0"
5’-0"
32’-6"
5’-0"
57’-9"
5’-0"
4" FCO I.E. 98’-6"
POC TO 6" SEWER I.E. 96’-0"(4400.50’) LATERAL WITH 4"x6" INCREASER, FOR CONTINUATION SEE CIVIL DRAWING CU-124
4"
POC TO 6" SEWER I.E. 96’-0" (4400.50’) LATERAL WITH 4"x6" INCREASER, FOR CONTINUATION SEE CIVIL DRAWING CU-124
POC TO 6" SEWER I.E. 96’-0"(4400.50’)LATERAL, FOR CONTINUATION SEE CIVIL DRAWING CU-124
S=2
%
MIN
S=2
%
MIN
4"
3" FCO
2" FCO
2"2"
FD-2
2"
2"
FD-1FS-1
2"
2"
F.F.E. = 100’ - 0" (4404.50’)
8’-6"
2"(TYP OF 4)4"
2"FS-1
4"
FS-1
FD-2
4"
FS-1
2"
4" FCO I.E. 98’-6"
21’-0" 7’-8"
FS-1
EWC-12"
4" FCO
2"FCOI.E. 98’-6"
2"
3" CW (140 GPM) BOP 96’-0" (4400.50’)CONNECT TO 3" WATER LATERAL, FOR CONTINUATION SEE CIVILDRAWING CU-124
S=2% MIN
C.
KO
RP
AS
H
156
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
UN
DE
R FLO
OR
AR
C-FIR
ST FLO
OR PLA
N-SE
CT
OR
TW
O -
PLU
MBIN
G
P-112A
07-2
8-1
1
M.
BE
TZ
LC
AR
C_P-1
12
A.d
gn
KEY NOTES
GENERAL NOTES
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
N
SHEET
REFERENCE
NUMBER:
2
9:2
3:2
6
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-112
A.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
KEY PLAN
ARC
OMS
A2
A1
B
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
4 5 6 7 8 119 109.8
A112
TER
A114
ELECTRICAL
A115
SIPRNET
CAFE
A116
FACILITY
MAINTENANCE
A118
WOMENS
LOCKER
A121
JANITORIAL
STORAGE
A122
MECH
A125
MENS
LOCKER
A126
PHYSICAL
READINESS
A127
BREAK
AREA
A128
STOR
A129
TRAINING AID
STORAGE
A130
LEARNING
CENTER
A131
CLASSROOM
A132
LIBRARY
STORAGE
A133
LIBRARY
READING
A134
CLASSROOM
A135
UNIT EXCLUSIVE
SPACE
A136
UNIT EXCLUSIVE
SPACE
A137
FULL TIME
OFF. SPACE
A138
FULL TIME
OFF. SPACE
A139
FULL TIME
OFF. SPACE
A140
FULL TIME
OFF. SPACE
A141
FULL TIME
OFF. SPACE
A113
EF
A120A
WOMENS
VESTIBULE
A123A
MENS
VESTIBULE
A120B
VESTIBULE
A123B
VESTIBULE
A150
INTERIOR
CORRIDOR
INTERIOR
YARD
A142
FULL TIME
OFF. SPACE
A143
UNIT
COMMON SPACE
A144
GENERAL
OFFICE
A145
ELEC
A146
RESTROOM
A147
FAMILY
SUPPORT
A148
RETENTION
A149A
SORTING
ROOM
A149B
DISTRIBUTION
ROOM
A119S
WOMENS
SHOWER
A119T
WOMENS
TOILET
A124T
MENS
TOILET
A124S
MENS
SHOWER
A117
MECHANICAL
EWC-1
1
2
3
4
5
6
7
1
4
4
6
8
1.
2.
3.
REFER TO ARCHITECTURAL DRAWINGS FOR FINISH FLOOR AND CEILING ELEVATIONS.
REFER TO MECHANICAL DRAWINGS FOR EQUIPMENT LOCATIONS.
PROVIDE HEAT TRACING ON ALL WATER PIPING IN THE EXTERIOR SOFFIT IN ACCORDANCE WITH SPECIFICATION SECTION 23 0515.
PIPING ABOVE CEILING
1/2" CW DN, 2" W DN & 2" V UP TO AND FROM EWC
2" V UP TO 3" V @ 12" BELOW ROOF & 3" VTR
3/4" CD UP FROM MECHANICAL EQUIPMENT, FIELD LOCATE POC
CD DN TO MS WITH 1" AIRGAP
3/4" CD FROM MECHANICAL EQUIPMENT AND DISCHARGE TO FS WITH 1" AIRGAP, SEE DWG P-112A FOR FS LOCATION
1" CD DN FROM MECHANICAL EQUIPMENT ON ROOF, FIELD LOCATE POC
1" CD DN FROM KITCHEN EQUIPMENT ON ROOF, FIELD LOCATE POC
7
1
4
1
7
7
75
2
15
8
2" ICW
1 1/2" (140 DEG F)
1
1" (140 DEG F)
3
1" HWR (135 DEG F)
1 1/2" ICW
3/4" CW
1-1/2" CW
1" HWR (135 DEG F)
S=1%
1" CD
3/4" CD
1"
CD
2"ICW
1/2" CW2"V
SEE GENERAL NOTE 3
SEE GENERAL NOTE 3
MA
TC
H
LIN
E
SE
E
SH
EE
T
P-122
A
MA
TC
H
LIN
E
SE
E
SH
EE
T
P-122
A
SCALE :1/8"=1’-0"A1
N
A1
P-412A
0 16’4’ 8’
C1
P-412A
C.
KO
RP
AS
H
157
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
AB
OVE FLO
OR
AR
C-FIR
ST FLO
OR PLA
N-SE
CT
OR
ON
E
PLU
MBIN
G
P-121A
07-2
8-1
1
ARC-FIRST FLOOR PLAN-SECTOR ONE - ABOVE FLOOR
M.
BE
TZ
LC
AR
C_P-1
21
A.d
gn
GENERAL NOTES
KEY NOTES
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
N
SHEET
REFERENCE
NUMBER:
2
9:2
4:0
9
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-121A.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
KEY PLAN
ARC
OMS
A2
A1
B
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
1 2 3 4
J
A101
LOBBY
A105A
WEAPONS
SIMULATOR RM.
A107
UNIT
STORAGE
A108
ARMS
VAULT
A109
ARMORER
WORK AREA
A110
STAGING
AREA
A111
SUPPLY
OFFICE
A102
ASSEMBLY
A103C
JANITOR
A103B
OFFICE
A103A
KITCHEN
A106
STORAGE
A104
TABLE AND
CHAIR STORAGE
A105B
CONTROL
ROOM
F
P
C
B
A
Q
K
M
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
18
17
18
1111
117
131311 1111
1
13
11
11
141516 1
3 5
7
7
11
69 10
1
2 2
19
20
19
20
1.
2.
3.
4.
5.
REFER TO ARCHITECTURAL DRAWINGS FOR FINISH FLOOR AND CEILING ELEVATIONS.
REFER TO MECHANICAL DRAWINGS FOR EQUIPMENT LOCATIONS.
WATER PIPING SHALL NOT RUN OVER ELEC ROOM A145.
PROVIDE HEAT TRACING ON ALL WATER PIPING IN THE EXTERIOR SOFFIT IN ACCORDANCE WITH SPECIFICATION SECTION 23 0515.
RUN WATER PIPING CLOSE TO THE NORTH WALL OF EF ROOM. PROVIDE DRAINAGE TROUGH AND RUN 3/4" TROUGH DRAIN TO NEAREST FLOOR SINK WITH 1" AIRGAP IN MECHANICAL A117, REFER TO DWG P-112A FOR FLOOR SINK LOCATIONS.
4
8 WHA-A
1/2"1
1" HWR (135 DEG F)
1" HW (140 DEG F)
2" ICW
1-1/2" CW
1" HWR (135F)
WC-2
1-1/2" ICW3/4" CW
S=1%
S=1%
S=1%
1" ICW
SK-1FWD-1
12
MV-1
1/2" CW1" ICW
1" ICW 1" ICW
S=1%
1"
1-1/4" ICW
1" CD
MV-1
1" CD1-1/2" HW (140F)
3/4" CD
PIPING ABOVE CEILING LEVEL
3/4" CD UP FROM MECHANICAL EQUIPMENT, FIELD LOCATE POC
1/2" HW & CW DN IN WALL TO MV-1 UNDERCOUNTER AND CONNECT TO L-1
PROVIDE QUARTER TURN ANGLE VALVE ( FOR REFRIGERATOR HOOK-UP) FROM CW STUB-OUT TO SINK FAUCET AND CAP OPEN END
2" W DN & 1-1/2" V UP FROM L-1
1/2" CW & 1/2" HW (140 DEG F) DN IN WALL TO MV-1 UNDER COUNTER AND CONNECT TO SK-1
2" V UP TO ABOVE CEILING LEVEL
WHA ABOVE CEILING LEVEL
1-1/4" ICW DN IN CHASE WITH VOR @ 5’-0" AFF BEHIND WAP & CONNECT TO WC, RUN 1/2" TP FROM TP-1 ON WC FLUSH VALVE.
4" S DN & 2" V UP TO 3" V @ 12" BELOW ROOF & 3" VTR
1" CD DN FROM MECH EQUIPMENT ON ROOF, FIELD LOCATE POC
1" CD DN IN WALL & DISCHARGE TO FS WITH 1" AIRGAP
3/4" ICW UP TO MECHANICAL EQUIPMENT ON ROOF WITH SOV, FIELD LOCATE POC
1" CD DN IN CHASE & DISCHARGE TO CDF-1 WITH 1" AIRGAP
CDF-1 BEHIND 12"x12" WAP WITH 2"W DN THRU FLOOR & 2" V UP TO 2" V FROM WC
SEE PLUMBING CHASE PIPING DIAGRAM A5/P-5020
1" CD DN TO MS & DISCHARGE WITH 1" AIRGAP
3/4" DOWN TO MS AND DISCHARGE WITH 1" AIRGAP
1 1/2" V UP AND OFFSET ABV CEILING, 2" W DOWN, AND 1/2" CW DOWN TO EWC-1
1 1/2"V UP TO 2" V @ 12" BELOW ROOF & 2" VTR
SEE GENERAL NOTE 3
EWC-1
SEE GENERAL NOTE 4
SEE GENERAL NOTE 5
MA
TC
H
LIN
E
SE
E
SH
EE
T
P-121A
MA
TC
H
LIN
E
SE
E
SH
EE
T
P-121A
N
SCALE :1/8"=1’-0"A1
C1
P-411A
0 16’4’ 8’
A1
P-411A
C.
KO
RP
AS
H
158
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
AB
OVE FLO
OR
AR
C-FIR
ST FLO
OR PLA
N-SE
CT
OR
TW
O
PLU
MBIN
G
P-122A
07-2
8-1
1
ARC-FIRST FLOOR PLAN-SECTOR TWO - ABOVE FLOOR
M.
BE
TZ
LC
AR
C_P-1
22
A.d
gn
GENERAL NOTES
KEY NOTES
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
N
SHEET
REFERENCE
NUMBER:
2
9:2
4:4
9
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-122
A.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
KEY PLAN
ARC
OMS
A2
A1
B
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
4 5 6 7 8 119 109.8
A112
TER
A114
ELECTRICAL
A115
SIPRNET
CAFE
A116
FACILITY
MAINTENANCE
A117
MECHANICAL
A118
WOMENS
LOCKER
A121
JANITORIAL
STORAGE
A122
MECH
A125
MENS
LOCKER
A126
PHYSICAL
READINESS
A127
BREAK
AREA
A128
STOR
A129
TRAINING AID
STORAGE
A130
LEARNING
CENTER
A131
CLASSROOM
A132
LIBRARY
STORAGE
A133
LIBRARY
READING
A134
CLASSROOM
A135
UNIT EXCLUSIVE
SPACE
A136
UNIT EXCLUSIVE
SPACE
A137
FULL TIME
OFF. SPACE
A138
FULL TIME
OFF. SPACE
A139
FULL TIME
OFF. SPACE
A140
FULL TIME
OFF. SPACE
A141
FULL TIME
OFF. SPACE
A113
EF
A120A
WOMENS
VESTIBULE
A123A
MENS
VESTIBULE
A120B
VESTIBULE
A123B
VESTIBULE
A150
INTERIOR
CORRIDOR
INTERIOR
YARD
A142
FULL TIME
OFF. SPACE
A143
UNIT
COMMON SPACE
A144
GENERAL
OFFICE
A145
ELEC
A146
RESTROOM
A147
FAMILY
SUPPORT
A148
RETENTION
A149A
SORTING
ROOM
A149B
DISTRIBUTION
ROOM
A119S
WOMENS
SHOWER
A119T
WOMENS
TOILET
A124T
MENS
TOILET
A124S
MENS
SHOWER
AD-1
HB-1
HB-1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
24
25
25
26
27
27
26
28
29
28
29
18
17
15
14
21
16
13
13
12
11
30
35
31
30
30
30 34
30 34
33
11
11
19
30
30
5
5
9
30
31
32
33
34
35
5
36
36
37
1.
2.
3.
REFER TO ARCHITECTURAL DRAWINGS FOR FINISH FLOOR AND CEILING ELEVATIONS.
REFER TO CIVIL DRAWING CG-119 FOR FINISH GRADING ELEVATIONS OUTSIDE THE BUILDING.
REFER TO STRUCTURAL DRAWING S-110B FOR FOUNDATION LOCATIONS.
PIPING BELOW FLOOR
2" V UP THRU FLOOR
2" W DN THRU FLOOR
3" W DN THRU FLOOR
2" V UP THRU FLOOR, OFFSET BELOW ROOF AND VTR
PIPING DOWN THRU FLOOR
UNDERGROUND PIPING, SEE C1/P-5010 FOR CONT
W OR S DN THRU FLOOR
1/2" TP DOWN THRU FLOOR TO FD OR AD
PIPING ABOVE DUCTBANK, FIELD COORDINATE LOCATION
PIPING ABOVE CEILING LEVEL
SEE INCOMING WATER DIAGRAM A3/P-5010
3/4" ICW DN TO HB-1 WITH V.O.R. @ 3’-0" AFF; POST A SIGN ABOVE HB THAT READS "INDUSTRIAL WATER - DO NOT DRINK."
1/2" CW DN TO EWC WITH V.O.R. @ 5’-0" AFF AND 1 1/2"V UP TO ABOVE CEILING LEVEL
1-1/4" HW & CW DN TO MIXING VALVE OF ESE WITH V.O.R. @ MIXING VALVE POC & MAKE 1-1/4" FINAL CONNECTION TO ESE; PROVIDE HEAT TRAP ON HW SUPPLY TO MIXING VALVE
1" HW & CW DN TO WF WITH V.O.R. @ 5’-0"AFFAND 1 1/2"V UP TO ABOVE CEILING LEVEL
1/2" HW & CW DN TO MS WITH V.O.R. @ 5’-0"AFF AND 2"V UP TO ABOVE CEILING LEVEL
3/4" CW DN WITH V.O.R. @ 5’-0" AFF
3/4" ICW UP TO MECH EQUIPMENT ON ROOF, FIELD LOCATE POC
1" CD DN FROM MECH EQUIPMENT ON ROOF, FIELD LOCATE POC
1" CD DISCHARGE ON MS WITH 1" AIRGAP
2" V I.E.4400.20’ CONNECT TO 2" V LATERAL, FOR CONTINUATION SEE CIVIL DWG CU-124
2" V UP THRU FLOOR & TIE-IN TO 2"V RISER @ 6" MINIMUM AFF
4" IW I.E. 94.67’ (4398.87’) CONNECT TO 4" LATERAL, FOR CONT. SEE CIVIL DWG CU-124
4" S I.E. 96’-0" (4400.20) CONNECT TO 6" SEWER LATERAL WITH 4"X6" INCREASER, FOR CONT. SEE CIVIL DWG CU-124
1 1/2" ICW BOP 96’-0" (4400.20’) CAP FOR FUTURE CONNECTION
2" CW (55 GPM) BOP 96’-0" (4400.20’) CONNECT TO 2" WATER LATERAL, FOR CON. SEE CIVIL DWG CU-124
1 1/2" ICW UP THRU FLOOR
2" CW (49.36 PSI) UP THRU FLOOR
PIPING @ TRUSS SPACE
3/4"PRODUCT PIPING DOWN TO HOSE REEL
PIPING ABOVE FOOTING
PIPING @ TRUSS SPACE, OFFSET AND DOWN ALONG WALL
1"LO(10W), 1"LO(15W40), 1"GRS, 1"LO(80W90), 1"ATF, AND 1"CA
HOSE REEL WITH 50’-0" HOSE MOUNTED @ 16’-0"AFF, SUPPORT FROM ROOF STRUCTURE
WATER METER WM-2 IN METER VAULT
36" SQUARE MIN FIBERGLASS SUMP FOR LEAK MONITORING BY AMERICAN CONTAINMENT MODEL AQ03L OR APPROVED EQUAL
4"
FS-1
FD-2
FD-1
FD-1
5
9
5
82"
8
10
2"
8 4"
10
4
3
3
4"
2"
2"
3"
1 4"
1 4"1W
1 2" 2
4" COTG I.E. 96’-0"
4" FCO I.E. 98’-0"
F.F.E. 100’-0"(4404.20’)
2
23
22
1 2"
4" COTG
S=2
%
MIN
S=2
%
MIN
11 1 1/2"
11 3/4"
F.F.E. 100’-0"(4404.20’)
1"WHA-A
WHA-A
3/4"
4" COTG
AD-1
FS-1
3/4" ICW
2" CW
1 1/2" ICW
1" ICW
TYP
TYP
3/4" ICW
1 1/2"CW
MS-2
WF-1
ESE-1
EWC-1
3/4"HWR
1 1/4"
BFP-2
20
7
32
5
112"
2"
3"
6 34 3/4"CW
MS-2
WF-1
4"COTG
9
WHA-A
EWC-1
1"ICW
37
GENERAL NOTES
SCALE :1/8"=1’-0"B2
N
OMS-BELOW FLOOR PLAN
SCALE :1/8"=1’-0"A2
A1
P-411B
A3
P-411B
C1
P-411B
C3
P-411B
23’-0"
22’-0"
5’-0"
5’-0"
5’-0"
N
5’-
0"
A4
P-5020
A4
P-5020
3’-1"
33’-1"
0 16’4’ 8’
0 16’4’ 8’
OMS-ABOVE FLOOR PLAN
C.
KO
RP
AS
H
159
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
OM
S-FLO
OR PLA
NS
PLU
MBIN
G
P-110B
07-2
8-1
1
M.
BE
TZ
LC
AR
C_P-1
10
B.d
gn
KEY NOTES
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
N
SHEET
REFERENCE
NUMBER:
2
9:2
2:1
0
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-110
B.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
KEY PLAN
ARC
OMS
A2
A1
B
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
1
B102
ELEC
B103
MECH
B104
STOR
B107
TOOLS
B108
WOMEN’S
B109
MEN’S
B110
SHOP
OFFICE
B111
SHOP
OFFICE
B112
SHOP
OFFICE
B113
VESTIBULE
B114
HALL
B115
VESTIBULE
B116
WORK
BAYS
B101B
STAGING
AREA
B106
TR
B101A
UNHEATED
STORAGE
B105
EQUIPMENT ALCOVE
2 3 4
C
B
A
1
B102
ELEC
B103
MECH
B104
STOR
B107
TOOLS
B108
WOMEN’S
B109
MEN’S
B110
SHOP
OFFICE
B111
SHOP
OFFICE
B112
SHOP
OFFICE
B113
VESTIBULE
B114
HALL
B115
VESTIBULE
B116
WORK
BAYS
B101B
STAGING
AREA
B106
TR
B101A
UNHEATED
STORAGE
B105
EQUIPMENT ALCOVE
2 3 4
C
B
A
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
20
6
10
12
5
3/4"
WHA-B1"
1" 1 1/4" 1 1/2" 5
927
11
WHA-C
2"
6
6
3/4"
15
14
13
2"
2 1/2"
1 1/2"
1 1/2"
1 1/4"2"
12
1 1/2"
7
1 1/4"
12
5 1"
1/2"
10
26
WHA-B
6
1 1/4"
71" 26 10 WHA-A
3/4"5
7 3/4"
1/2"
3/4" 1/2"1"1 1/2"2"
8
5
9
103/4"
2"
2"
2"
2"
2"
3"
2"
2"
SH-1
SH-1
SH-1
SH-2
L-1
WC-1
L-1
L-1
L-1
L-1
WC-1
WC-1
WC-2
4"
2"
2"
4"
2"
2"
2"
SH-1
SH-1
SH-1
SH-2SH-2
SH-1
SH-1
SH-1
2"
2"
2"
2"
3"
3"
2"4"
2" 3"
4"
WC-2
WC-2
WC-1
WC-1
WC-1
L-1
L-1UR-1
L-1
L-1
2"
3"
4"
L-1
3"
2" 1 1/2"
3" 2"
1 1/2"2"
2"
2"
1 1/2"
2"
WC
O
WC
O
WC
OW
CO
WC
O
WC
O
WC
O
UR-1
UR-1
UR-1
UR-2
FOR LOCATIONS OF ADA TYPE FIXTURES, REFER TO ARCHITECTURAL ENLARGED TOILET ROOM PLANS AND ELEVATIONS.
FOR WALL ACCESS PANEL MOUNTING HEIGHTS, TYPES, AND LOCATIONS, REFER TO ARCHITECTURAL SPECIFICATIONS.
REFER TO ARCHITECTURAL DRAWINGS FOR FINISH FLOOR AND CEILING ELEVATIONS.
1.
2.
3.
3/4"
1/2"
1 1/2"
1 1/4"
2 1/2" ICW
3" CW
1 1/2" CW
2" CW
2" ICW
19
CP-1
CP-2HWR ASSEMBLY (TYP)SEE A2/P-5020
1" HWRBFP-1
25
3
1
23
15
2 3
2
2
5
2
1
3
52NOTE :
FOR UNDER FLOOR PIPING INCLUDING FLOOR SINKS, FLOOR DRAIN, AND SHOWER DRAIN LOCATIONS SEE DWG P-112A.
2
3
6
2 332
6
32
6
1
5
2
6
2
6
6
2 4
15
1
2
2"2 3
6
6
6
2"3
2"3
2"3
2"3
2" 6
2" 6
17
3
3
2"
SH-1
SH-1
SH-1
SH-2
SH-1
SH-1
SH-1
SH-2
UR-1
UR-1
UR-1
UR-1
UR-2
L-1
L-1
L-1
L-1
L-1
L-1
WC-1
WC-1
WC-1
WC-2
WC-2
WC-2
WC-1
WC-1
WC-1
L-1
L-1
WHA-A
18
SH-1
SH-1
SH-1
SH-2
L-1
L-1
6 1" ICW
2" ICW
25
WS-1
MS-1
2"ICW
2" ICW
2" CW
TP-1TP-1
27
WHA-C
6 2"
2416
21GPR-1
2223
6
2" SW
W OR S DOWN THRU FLOOR
2" V UP THRU FLOOR
V UP TO ABOVE CEILING LEVEL
4" V UP TO VTR
PIPING IN WALL OR CHASE
PIPING ABOVE CEILING LEVEL
HW & CW DN IN WALL W/ VOR @ 5’-0"AFF BEHIND 12x12 WAP
3/4" CW, 3/4" HW & 2" ICW DN IN WALL W/ VOR @ 5’-0"AFF BEHIND 12x12 WAP
1/2" TP THRU WALL & DN THRU FLOOR
WHA BEHIND 8x8 WAP @ 18" AFF
2" ICW DN IN WALL W/ VOR @ 5’-0"AFF BEHIND 12x12 WAP
1/2" CW TO TP-2 BEHIND 8x8 WAP @ 5’-0" AFF & DN THRU FLOOR
UP FOR DISTRIBUTION TO FIXTURES, SEE B5/P-5020
2" CW DN TO WS-1 WITH VOR @ 6’-0" AFF
2" SW UP TO ABOVE CEILING LEVEL WITH VOR @ 6’-0" AFF
SEE INCOMING WATER DIAGRAM B3/P-5010
3" V UP TO VTR
3/4" ICW UP TO MECH EQUIPT ON ROOF WITH SOV, FIELD LOCATE POC
POC TO 2" HW SUPPLY AND RETURN, FOR CONTINUATION SEE DWG M-400A
POC TO 1" MAKE-UP WATER TO MECHANICAL EQUIPMENT, FOR CONTINUATION SEE DWG M-400A
POC TO GAS MAIN STUB-UP WITH VOR @ 12" AFG, SEE CIVIL DWG CU1000 FOR PIPE CONTINUATION
PROVIDE GROUND SUPPORT FOR GPR-1
2" G THRU WALL, FIRE SEAL WALL PENETRATION
2" G UP TO ABOVE CEILING LEVEl, WITH EMERGENCY GAS SHUT-OFF VALVE (ASCO MODEL 8042C075 OR APPROVED EQUAL) @ 4’-0" AFF, SEE ELECTRICAL DWG EP-114A FOR POWER HOOK-UP
1-1/4" G DOWN TO BOILERS WITH SEDIMENT TRAP, FIELD LOCATE POC AND CONNECT TO BOILER WITH FLEXIBLE CONNECTOR DOWNSTREAM OF LINE WITH SOV
1/2" CW TO TP-2 BEHIND 8x8 WAP @ 18" AFF
WHA BEHIND 8x8 WAP @ 24" AFF
WATER METER WM-1 REMOTE READOUT MOUNTED ON WALL @ 5’-0"AFF (FIELD LOCATE), SEE DWG EP-114A FOR POWER HOOK-UP
28
EQV-2GM-1
WATER TREATMENT
WT-1
C1 SCALE :1/4"=1’-0"
N
A1 SCALE :1/4"=1’-0"
0 2’ 4’ 8’ENLARGED TOILET, LOCKER, AND SHOWER ROOMS
ENLARGED TOILET, LOCKER, AND SHOWER ROOMS
N
0 2’ 4’ 8’
C.
KO
RP
AS
H
160
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
SH
OW
ER
RO
OM
PLA
NS
AR
C-E
NLA
RG
ED
TOIL
ET, LO
CK
ER
AN
D
PLU
MBIN
G
P-411A
07-2
8-1
1
1’-0"
1’-0"
1’-0"
3’-4"
1’-8"
1’-11"
6’-7"
1’-6"
1’-1"
9�"6’-5"
5’-4�"
M.
BE
TZ
LC
AR
C_P-4
11
A.d
gn
KEY NOTES
GENERAL NOTES
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
N
SHEET
REFERENCE
NUMBER:
2
9:2
5:4
4
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-4
11A.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
KEY PLAN
ARC
OMS
A2
A1
B
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
SIPRNET FACILITY
A118
WOMENS
LOCKER
A121
JANITORIAL
STORAGE
A122
MECH
A120
WOMENS
VESTIBULE
A123
MENS
VESTIBULE
A125
MENS
LOCKER
A119T
WOMENS
TOILET
A119S
WOMENS
SHOWER
A124S
SHOWER
MENS
A124T
MENS
TOILET
A117
MECHANICAL
5 6 7 8
E
D
G
5 6 7 8
E
D
G
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
11
13
10 12
14
15
3
MV-1
4
MV-1
4
MV-1
9
6 7 5
8
1/2"
1/2"
3/4"
1/2"
1/2"
3/4"
1 1/4"
1"
1 1/4" 1 1/2"
1 1/2"
3/4"
1/2"
1/2"
1/2"
3/4"
1/2" 1/2"
3/4"
3/4"
1 1/2"
1
16
16
16
26
29
16
16
16
23
2116
17
24
27
27
25
16 16 16 16
28
19
17
19
18
16
22
16
20
1 1/2"
2"
2"
3"
2"
2"
2" 2"
2" 2"
1 1/2"
3" 3"2"
3"
2"
2"2"
2" 2" 2" 2"
3"
1 2"V
1
1
1
1
2
NOTE:
FOR UNDER FLOOR PIPING INCLUDING FLOOR SINK AND FLOOR DRAIN LOCATIONS SEE DWG P-111A.
30
30
30
1"
30 30
30
3/4"
1"
1.
2.
3.
4.
5.
6.
WATER FILTER31
17
14 15
8
47
41
38
35
45
42
40
31
7
8
32
8
14
17
38
36
45
7
8
32
37
35
42
43
26
27
REFER TO KITCHEN DRAWINGS FOR KITCHEN EQUIPMENT LAYOUT AND EQUIPMENT ITEM NUMBER DESCRIPTION.
REFER TO KITCHEN DRAWINGS FOR KITCHEN EQUIPMENT UTILITY ROUGH-INS, POINT OF CONNECTIONS, AND UTILITY SIZES.
UTILITY STUB-OUTS THRU WALL SHALL BE PROVIDED WITH ISOLATION VALVES (SAME SIZE AS STUB OUT).
FIELD LOCATE POC TO KITCHEN EQUIPMENT AND MAKE FINAL CONNECTIONS.
REFER TO STRUCTURAL DRAWING S-111A FOR FOUNDATION LOCATIONS.
REFER TO MECHANICAL DRAWINGS FOR MECHANICAL EQUIPMENT LOCATIONS.
PIPING ABOVE CEILING LEVEL
3"V UP TO ABOVE CEILING LEVEL
1/2" HW, 1/2" CW, & 1/2" FCW DN IN WALL TO ITEM 7
1/2" HW, & CW DN IN WALL TO ITEM 8; PROVIDE MV-1
3/4" CW DN IN WALL TO ITEM 14 WATER FILTER AND RUN 3/4" FCW TO ITEM 14 (PIPING NOT SHOWN)
3/4" CW DN IN WALL TO ITEM 14
1/2" HW & CW DN IN WALL TO ITEM 15
1/2" HW & CW DN IN WALL TO ITEM 17
1/2" FCW DN IN WALL TO ITEM 32
1/2" HW & CW DN IN WALL TO ITEM 35
1/2" HW & CW DN IN WALL TO ITEM 38
3/4" CW DN TO ITEM 40 WITH VOR @ 5’-0" AFF; 3/4" FCW UP TO ABOVE CEILING FROM ITEM 40 WITH VOR @ 5’-0" AFF
3/4" HW & CW DN IN WALL TO ITEM 41 & 47
1/2" FCW DN IN WALL TO ITEM 42
1/2" HW & CW DN IN WALL TO ITEM 45; PROVIDE MV-1 NEXT
2" V UP TO ABOVE CEILING LEVEL
1 1/2" V UP TO ABOVE CEILING & 2" W DOWN FROM ITEM 8
4" V UP TO VTR
1 1/2" DRAIN FROM ITEM 7 DISCHARGE TO FS WITH 1" AIRGAP
2" DRAIN FROM ITEM 14 DISCHARGE TO FS WITH 1" AIRGAP
1" DRAIN FROM ITEM 26 DISCHARGE TO FS WITH 1" AIRGAP
1" DRAIN FROM ITEM 27 DISCHARGE TO FS WITH 1" AIRGAP
3/4" DRAIN FROM ITEM 32 DISCHARGE TO FS WITH 1" AIRGAP
2" DRAIN FROM ITEM 35 DISCHARGE TO FS WITH 1" AIRGAP
3/4" DRAIN FROM ITEM 36 DISCHARGE TO NEAREST FS WITH 1" AIRGAP
1/2" DRAIN FROM ITEM 37 DISCHARGE TO NEAREST FS WITH 1" AIRGAP
CONNECT 2" DRAIN FROM DISPOSER TO WASTE PULPER ON ITEM 38; 2" DRAIN FROM ITEM 38 (WASTE PULPER) DISCHARGE TO FS WITH 1" AIRGAP
1/2" & 3/4" DRAIN FROM ITEM 42 DISCHARGE TO FS WITH 1" AIRGAP
1 1/2" DRAIN FROM ITEM 43 DISCHARGE TO FS WITH 1" AIRGAP
3/4" ICW UP TO MECH EQUIPT ON ROOF WITH SOV, FIELD LOCATE POC
MOUNT WATER FILTER ON WALL AND PROVIDE INLET AND OUTLET SHUT-OFF VALVES
C1 SCALE :1/4"=1’-0"
N
A1 SCALE :1/4"=1’-0"
0 2’ 4’ 8’
N
0 2’ 4’ 8’
ARC - ENLARGED KITCHEN PLAN - DOMESTIC WATER
ARC - ENLARGED KITCHEN PLAN - VENT
-- = 1’-0"
-
C.
KO
RP
AS
H
161
11-1
5-1
0
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
AR
C-E
NLA
RG
E
KIT
CH
EN
PLA
NS
PLU
MBIN
G
P-412A
07-2
8-1
1
M.
BE
TZ
LC
AR
C_P-4
12
A.d
gn
KEY NOTES
GENERAL NOTES
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
N
SHEET
REFERENCE
NUMBER:
2
9:2
7:4
4
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-4
12
A.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
KEY PLAN
ARC
OMS
A2
A1
B
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
1 2 3
KITCHEN
REQUIRES
42" DOOR!
K
M
1 2 3
K
M
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
21
21
3 6
3
3
24
FOR LOCATIONS OF ADA TYPE FIXTURES, REFER TO ARCHITECTURAL ENLARGED TOILET ROOM PLANS AND ELEVATIONS.
FOR WALL ACCESS PANELS MOUNTING HEIGHTS, TYPES, AND LOCATIONS REFER TO ARCHITECTURAL SPECIFICATONS.
REFER TO ARCHITECTURAL DRAWINGS FOR FINISH FLOOR AND CEILING ELEVATIONS.
REFER TO STRUCTURAL DRAWINGS FOR HOUSE KEEPING PAD LOCATIONS AND INFORMATION.
1.
2.
3.
4.
PIPING ABOVE CEILING LEVEL
2" W DN THRU FLOOR & 1-1/2"V UP
2" V UP THRU FLOOR
2" V UP TO ABOVE CEILING
4" S DN THRU FLOOR & 2" V UP
2" V UP TO 3"V @ 12" BELOW ROOF & 3" VTR
1/2" HW & CW DN IN WALL TO L-1
1/2" HW & 3/4"CW DN IN WALL TO FIXTURES
1-1/2" ICW DN IN WALL W/ VOR @ 5’-0"AFF BEHIND 12x12 WAP
WHA BEHIND 8x8 WAP @ 18" AFF
1/2" TP THRU WALL & DN THRU FLOOR
3/4" CW DN TO HB WITH VOR @ 5’-0" AFF
1/2" CW DN TO TP WITH VOR, SEE B4/P-5020
1-1/2" CW DN ALONG WALL WITH VOR @ 6’-0" AFF
FOR TMV PIPING LAYOUT, SEE B5/P-5020
POC TO GAS MAIN STUB-UP WITH VOR @ 12" AFG, SEE CIVIL DWG CU1000 FOR PIPE CONT
PROVIDE GROUND OR WALL SUPPORT ON GPR-2
1-1/2" G THRU WALL, FIRE SEAL WALL PENETRATION
1"G DN TO BOILERS WITH SEDIMENT TRAP. FIELD LOCATE POC, CONNECT INDIVIDUALLY TO EACH BOILER WITH FLEXIBLE CONNECTOR DOWNSTREAM OF SOVS
POC TO 1" MAKE-UP WATER TO MECHANICAL EQUIPMENT, FOR CONTINUATION SEE DRAWING M-400B
2" V PIPING @ 12" MINIMUM ABOVE FLOOR
TP DOWN THRU FLOOR TO FD, SEE B4/P-5020
FOR DWH-1 PIPING LAYOUT, SEE B1/P-5020
WATER METER WM-2 REMOTE READOUT MOUNTED ON WALL @ 5-0" AFF ( FIELD LOCATE), SEE DWG EP-120B FOR POWER HOOK UP
2"
2
1
3 4
5 6 1
12"
2"
3
2 L-1
WC-2
4" WCO
WC-2
L-1
71 3/4" HWR
L-1
L-1
WC-2
WC-2
13/4"1/2"
3/4"
1/2"
3/4"
1/2"
3/4"
1 1 1/2" ICW
11
11
TP-1
TP-1
WHA-B
9
HB-1
8
17
18
16
12
1 1-1/2"G
19
13 TP-21
GPR-2
14115
1 1/4"
TMV-2
CP-3
1 1/2"
3/4"
1 1/4"
DWH-1 23
HB-1
1 1/2"
1 1/2"
1
10
1-1/4"
WS-2
1 1/4"HW
3/4" HWR
1 1/2"CW
22
1 1/4" HW
20
11"ICW
2UR-2
UR-2
24
GM-2
EQV-3
WS-2
AC-1
AC-1
TMV-2 CP-3
DWH-1
C1 SCALE :1/2"=1’-0" N
A1 SCALE :1/2"=1’-0"
N
A3 SCALE :1/2"=1’-0"
C3 SCALE :1/2"=1’-0"
OMS - ENLARGED RESTROOM PLAN - WASTE AND VENT
OMS - ENLARGED RESTROOM PLAN - WATEROMS - ENLARGED MECH ROOM B103 - WATER & NATURAL GAS
OMS - ENLARGED MECH ROOM B103 - VENT
N
N
0 2’ 4’1’ 0 2’ 4’1’
0 2’ 4’1’0 2’ 4’1’
C.
KO
RP
AS
H
162
OM
S-E
NLA
RG
ED
PLA
NS
11-1
5-1
0
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
PLU
MBIN
G
P-411B
07-2
8-1
1
M.
BE
TZ
LC
AR
C_P-4
11
B.d
gn
KEY NOTES
GENERAL NOTES
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
N
SHEET
REFERENCE
NUMBER:
2
9:2
6:4
5
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-4
11B.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
KEY PLAN
ARC
OMS
A2
A1
B
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
ATF
80W90FLAMMABLE STORAGE
U/G WATER MAIN U/G CW
RUN AIRGAP FUNNEL DRAIN TO NEAREST FS WITH 1" AIRGAP
U/G WATER MAIN U/G CW
NOTES:
AIRGAP FUNNEL DRAIN TO DISCHARGE ON FLOOR
PIPE CLAMP
BOLT TO FLOOR
STANDARD FITTING BRACKET
DRAIN LINEFLOOR SINK
FIN. FLOOR
A5NO SCALE
INDIRECT WASTE PIPING TO FLOOR SINK DETAIL
FINISH GRADE
FLOW
B5NO SCALE
NO SCALEC1 C3
NO SCALE
CAST IRON FERRULE W/COUNTERSUNK BRONZEPLUG
12" SQ. X 8" DEEPCONCRETE PAD
CLEANOUT TO GRADE DETAIL
FOR CLEANOUT AT ENDOF LINE, PLUG WYE ATTHIS POINT
EXTENSION LENGTHAS REQUIRED
OVER OPEN PORTION
OF GRATE WITH 1" AIRGAP
TERMINATE DRAIN LINE
(DETAIL SIMILAR FOR TRAP PRIMING)
FL
AM
MA
BL
E
CO
NT
RO
LL
ED
WA
ST
E
PIPE ROUTING BETWEEN FLAMMABLE STORAGE AND OMS WASH PLATFORM
1
2
3
4
5
2
3
52"
4" 5
4
41
1" 5
5’-0"
NO SCALEA1
ENLARGED PLAN - FLAMMABLE STORAGE
GRS
10W 15W40
EEW-1
3/
4"
CW
1"
LO (10
W)
1"
LO (15
W40)
1"
GR
S
1"
LO (80
W90)
1"
ATF
1"
CA
MIXING VALVE
24" DIA. 24" DIA.
24" DIA.
20" DIA.
6"6" 6"
NO SCALEB3
F.F.E.
HB-2 HB-2
SI-1
BFP-1
18"
18"
2-1/2"
DOMESTIC COLD WATER BUILDING SUPPLY
ICW TO WATER CLOSETS AND MECHANICAL EQUIPMENT
3"
2-1/2"
NC
2-1/2" 2-1/2"
INCOMING WATER DIAGRAM - ARC
NO SCALEA3
F.F.E.
BFP-2
18"
12"
1-1/2"
DOMESTIC COLD WATER BUILDING SUPPLY
2"
1-1/2"
NC
1-1/2"
1-1/2"
INCOMING WATER DIAGRAM - OMS
ICW TO WATER CLOSETS, MECHANICAL EQUIPMENT & HB
1/2" TP
TO FD
TP-2
48" WIDE BY 36" DEEPTRENCH (MINIMUM)
S=2% MIN
6
7
7 5 2"
6
BALL VALVE(TYP)
CHECK VALVE
BALL VALVE(TYP)
CHECK VALVE
24" DIA.
BALL VALVE (TYP)
PRODUCT PUMP MOUNTEDON DRUM (TYP)
FLEXIBLE HOSE FROM CA MANIFOLD TOPRODUCT PUMP (TYP)
FLEXIBLE HOSE FROM PRODUCT PUMP TO PRODUCTPIPING ON WALL (TYP)
SUPPORT PIPING (STACK VERTICALLY) ON WALL
SEE SHEET P-5010, DETAIL A1
N
3"
2"
DWH-1TMV-2
HW 140F
ET-1
1-1/2"
1-1/4"
3/4"
1-1/4"
HWR 115F
3/4"
HW 120F
1-1/4" 1-1/4"
C5NO SCALE
3/4"
1-1/4"
CW
1-1/4"
1-1/4"
OMS - MECH B103 - HOT WATER PIPING DIAGRAM
CBV-1A
CBV-1A
CHECK VALVE(TYP)
BALL VALVE(TYP)
FOR CONT SEE B2/P-110B
KEYNOTES
CP-3
NOTES:
1. FOR TMV PIPING LAYOUT, SEE B5/P-5020.
2. FOR DWH PIPING LAYOUT, SEE B1/P-5020
3. FOR CP PIPING LAYOUT, SEE C1/P-5020FOR HOSE BIBB AND VENT RISER PROTECTION, SEE CIVIL DRAWING CU-124.
N
N
TP-2
1/2" TP TO AD
INSTANTANEOUS WATER HEATER
2" CAHEADER
2" CA HEADER
TOP OF GRATE = 4406.14
FFE = 4406.50 @ CORNERS
C.
KO
RP
AS
H
163
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
DET
AIL
S
PLU
MBIN
G
P-5010
07-2
8-1
1
NOTE
POC TO 1" CW BOP 4403.10’ LATERAL, FOR CONTINUATION SEE CIVIL DRAWING CU-124
POC TO 4" WASTE I.E. 4403.10’ LATERAL, FORCONTINUATION SEE CIVIL DRAWING CU-124
2" V UP & TERMINATE @ 10’ AFG; PROVIDE GROUND SUPPORT
1" CW UP TO HB-2
PIPING BELOW SLAB OR GRADE
POC TO 2" V I.E. 4403.60’ LATERAL, FORCONTINUATION SEE CIVIL DWG CU-124
2"V UP & TIE IN TO 2"V STACK AT 6" MINIMUM ABOVE FINISH GRADE
3/4" CW1" LO (10W)1" LO (15W40)1" GRS1" LO (80W90)1" ATF1" CA
SUMP SENSOR
VEEDER-ROOT SUMP SENSOR MODEL NUMBER 794380-208 OR APPROVED EQUAL AT EACH CORNER
WRAP PIPING PENETRATING FLAMMABLE STORAGE WITH 1-1/2" THICK INSULATION.
FIRE SEAL PENETRATIONS THROUGH FLAMMABLE STORAGE TO MAINTAIN WALL RATING.
CONSULT WITH STORAGE MANUFACTURER HOW TO ATTACH WALL SUPPORTS WITHOUT COMPROMISING WALL STRUCTURE AND RATING.
RUN UNDERGROUND 3/4" TEPID WATER FROM INSTANTANEOUS WATER HEATER AND CONNECT TO EEW-1. REFER TO MANUFACTURER’S INSTALLATION INSTRUCTIONS.
INSTALL SUMP SENSORS PER MANUFACTURER’S INSTALLATION INSTRUCTIONS. PROVIDE REQUIRED SENSOR CABLE LENGTHS FROM SENSORS TO MONITORING CONSOLE.
INSTALL ENCLOSURE AND SUMPS PER MANUFACTURER’S INSTALLATION INSTRUCTIONS.
1.
2.
3.
4.
5.
6.
SUMP SENSOR
73"x67" 2-PIECE SECTIONAL ALUMINUM FREEZE PROTECTION ENCLOSURE (MINIMUM) WITH 85"x79" FIBERGLASS MOUNTING PAD"HOT BOX" MODEL HB8000AET OR APPROVED EQUAL.
VEEDER-ROOT TLS-350 PLUS MONITORING CONSOLE MODEL NUMBER 848290-022 OR APPROVED EQUAL MOUNTED ON WALL @ 5’-0" AFF (FIELD LOCATE)SEE DWG EP120B FOR POWER HOOK-UP
36" SQUARE FIBERGLASS SUMP FOR LEAK MONITORING BY AMERICAN CONTAINMENT MODEL AQ03L OR APPROVED EQUAL.
36" SQUARE MIN LEAK MONITORING SUMP
M.
BE
TZ
LC
AR
C_P-5
010.d
gn
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
SHEET
REFERENCE
NUMBER:
2
9:2
8:1
6
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-5010.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
14
+00
5+00
NOTE:
PROVIDE CLEANOUTS AT THE BASE OF ALL
VERTICAL WASTE STACKS
TEST TEE USEFOR CLEANOUT
FINISH FLOOR
10
6
8
5
2
3
10
7
4
9
1 1 1
1
2
3
4
5
6
7
8
9
10
12" DOMESTIC WATER LINE
BALL VALVE
12"
12"
12"
FINISH FLOOR
UNION (TYP)
DISTRIBUTION UNIT (WHERE REQUIRED)
18"
6" (
MIN)
ROUND FLANGED
CLEANOUT
HOUSING
18" BEND
SOIL PIPE
WYE BRANCH
SOIL PIPE
NOTE:
VARIES
DEPENDING ON
SIZE
VARIES
DEPENDING ON
SIZE
VARIES
DEPENDING ON
SIZE
DRAIN
PORT
BRONZE ANNULAR
CORRUGATED HOSE
AND SINGLE
BRONZE BRAID
COPPER
FERRULE (TYP)
1. PROVIDE UL LISTED CABLE HANGER ASSEMBLIES PER
MANUFACTURER’S REQUIREMENT.
FINISH FLOOR AREA DRAIN (AD-1)
FOR TRENCH DRAIN CONCRETE DETAIL, REFER TO STRUCTURAL
DRAWINGS.
COORDINATE LOCATION AND INSTALL AREA DRAIN BEFORE CONCRETE
POUR.
NOTES:
2’-
0"
A3NO SCALE
EXPOSED WASTE CLEANOUT DETAILNO SCALE
A4
NO SCALEB4
TRAP PRIMING DETAIL
C4N.T.S.
C5N.T.S.
FLOOR CLEANOUT DETAILEXPANSION JOINT DETAIL FOR COPPER PIPING
TRAP PRIMER
AIR GAP FITTING
12" SOFT COPPER TUBING
WITH NO JOINTS (TYP)
FLOOR DRAIN (TYP)
NOTES:
1.
2.
3.
TRENCH DRAIN
LONG SWEEP 14" BEND OR
COMBO "Y" & 18" BEND
PROVIDE DISTRIBUTION UNIT DOWNSTREAM OF TRAP PRIMER AND
AIR GAP FITTING, WHERE REQUIRED, TO PROVIDE TRAP PRIMING
TO MULTIPLE FLOOR DRAINS AND/OR FLOOR SINK, REFER TO
FLOOR PLANS.
RUN TRAP PRIMER TO FLOOR ABOVE FLOOR, SINK, SEE DETAIL
A5/P-5000.
PROVIDE WALL ACCESS PANEL WHERE TRAP PRIMER IS INSIDE
WALL OR CHASE.
(DETAIL SIMILAR FOR CARBON STEEL PIPING)
1.
2.
NO HUB COUPLING
1-1/4" INCOMING WATER
TO TMV-2
1-
1/
4"
NO SCALEB1
OMS - SOLAR ELECTRICAL PACKAGE SYSTEM LAYOUT
FINISH FLOOR
METAL DRAIN PAN
AT LEAST 2"
GREATER THAN
WATER HEATER
DIAMETER
ET-1
BALL VALVE
(TYP)
CHECK VALVE
BALL VALVE
(TYP)
UNION(TYP)
CHECK VALVE
CALIBRATED BALANCE VALVE (CBV)
DIRECTION OF FLOW
NO SCALEA2
BALL VALVE
(TYP)
B5NO SCALE
TMV PIPING DETAIL
140
o
F
HW
120
o
F
HW
TMV
FINISH FLOOR
4’-
0"
HEAT TRAP
27" DROP
CHECK VALVE
THERMOMETER
UNION
NOTES:
1.) FOR PIPE SIZES SEE PLANS AND SCHEDULES
2.) FIELD LOCATE AND PROVIDE WALL SUPPORTS.
TE
PID
WA
TE
R
NOTE:
NUMBERED ITEMS ARE SYSTEM COMPONENT OF THE SOLAR
ELECTRIC PACKAGED SYSTEM.
1" AIR GAP
A5NO SCALE
RESTROOM A145 PLUMBING CHASE PIPING DIAGRAM
1-1/4"
FINISH FLOOR
1" CD
2" V
2" W 1/2" TP
TO FD-1
TP-1
WC-2
CDF-1
SOLAR COLLECTOR MOUNTED ON ROOF (SEE ARCH ROOF PLAN
FOR LOCATION)
SOLAR STORAGE TANK
HEAT EXCHANGER (NOT SHOWN. INSIDE SOLAR STORAGE TANK)
EXPANSION TANK
TEMPERATURE AND PRESSURE RELIEF VALVE
AIR VENT
DRAIN VALVE
MIXING VALVE
SOLAR PUMP STATION (FIELD LOCATE)
TEMPERATURE SENSOR
HOT WATER RETURN (HWR) ASSEMBLY
NOTE: SEE PLANS FOR SIZES AND LOCATIONS.
TRENCH DRAIN DETAIL
12x12 WAP @ 24"
AFF IN FRONT OF
CDF-1
SOV BEHIND WAP @
5’-0" AFF
TP-2 BEHIND
8x8 WAP @
18" AFF
C.
KO
RP
AS
H
164
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
DET
AIL
S
PLU
MBIN
G
P-5020
07-2
8-1
1
M.
BE
TZ
LC
AR
C_P-5
020.d
gn
EXPOSED WASTEPIPE
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
SHEET
REFERENCE
NUMBER:
2
9:2
8:4
4
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-5020.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
DIRECTION OF FLOW
SEISMIC BRACE
2 MAX1 MIN
1
"A" "A"
DIAMETER PLUS ONE INCH MINIMUM
"A" = PIPE AND INSULATION
NOTE
5’-0" MAX
SEE NOTE 4 (TYP.)
SEE NOTE 5 (TYP.)
SEE NOTE 3
SADDLE 12" LONG
18 GAGE GALVANIZEDSEE NOTE 3
NOTES:
1. ANCHOR BOLT SIZE AND QUANTITY PER SMACNA REQUIREMENTS.
2. PIPE INSULATION IS NOT SHOWN FOR CLARITY.
3. PROVIDE DOUBLE WASHER AND NUT ASSEMBLY.
4. OPTIONAL HORIZONTAL SEISMIC RESTRAINT.
5. STRUCTURAL MEMBER, REFER TO STRUCTURAL PLANS.
PER SMACNA AND
UFC 3-301-01 (TYP.)
POLISHED
CHROME
ACCESS COVER
B4NO SCALE
NO SCALEA4
NO SCALEC3
WALL CLEANOUT DETAILS
A3NO SCALE
PENETRATION DETAILS TRAP PRIMER (TP-1) TYPICAL DETAIL
TWO WAY CLEANOUT DETAIL
D4NO SCALE
ROOF PIPE SUPPORT
NO SCALEC1
CIRCULATING PUMP PIPING DIAGRAM
FINISH WALL SURFACE
ACCESS COVER AND FRAMETEST TEE
MAY EXTEND AS
WASTE OR VENT
CLEAN OUT
PLUG
COUNTERSUNK
SCREW
1/8" BEND AND END
OF LINE CLEAN OUT
WASTE LINE
FLOW
THREADED CLEAN OUT PLUG
METAL JACKET
INSULATION
2"
INSULATED
(SEE SPECIFICATIONS)
FIRE SAFING INSULATION
U.L. LISTED SEALANT &
PIPE
PIPE SLEEVE
SCH. 40 STEEL
NON-INSULATED
WALL
LC
PIPE SLEEVE
ESCUTCHEON
PIPE
METAL JACKET
INSULATION
RE: SPECIFICATIONS
NON-INSULATED
INSULATED
U.L. LISTED SEALANT &
FIRE SAFING (SEE SPECS)
FINISH FLOOR
CLEAN OUT TEE
FOR WALL
CONSTRUCTION REFER
ARCH DWGS
FINISH FLOOR
INSULATED PIPING
ROOF PIPE SUPPORT
(ERICO, MIFAB, OR
APPROVED EQUAL)
RECESSED FERRULE AND
SCREW PLUG
CAST IRON MAIN
SIZE OR 4" MAX
CONCRETE PAD
1/4 YARD CONCRETE
AROUND FITTING FOR
ANCHOR
WALL
ESCUTCHEON
TRAP PRIMER
(TP-1)
WATER CLOSET
FLOOR DRAIN WITH
TRAP PRIMER
CONNECTION
1/2" TRAP PRIMER
PIPING
FINISH FLOOR
CHECK VALVE
CIRCULATING PUMP
AQUASTAT
BALL VALVE
(TYP)
NOTES:
1. REFER TO PLANS AND SCHEDULES FOR PUMP LOCATION AND SIZE.
2. PIPING AND VALVING SHALL BE SAME SIZE AS PUMP.
NOTE:
HANGER ROD
SIZED FOR LOAD
MATCH OD OF PIPE FOR UNINSULATED LINES.
18 GAGE GALVSADDLE 12" LONG
ADJUSTABLE
WROUGHT CLEVIS
INSULATION (RIGID INSULATION
PIPE
MATCH OD OF INSULATION FOR INSULATED LINE,
18" LONG CENTERED ON
SUPPORT)
MATCH OD OF INSULATION FOR INSULATED LINE,MATCH OD OF INSULATION FOR INSULATED LINE,
REFER TO SMACNA SEISMIC RESTRAINT MANUAL ANDUFC 3-301-01
SLOPE
FINISH GRADE
C.
KO
RP
AS
H
165
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
DET
AIL
S
PLU
MBIN
G
P-5030
07-2
8-1
1
N.T.S.B1
PIPE HANGER DETAIL - SINGLE PIPE
N.T.S.A1
PIPE HANGER DETAIL - TRAPEZE TYPE
M.
BE
TZ
LC
AR
C_P-5
030.d
gn
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
SHEET
REFERENCE
NUMBER:
2
9:2
9:1
4
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-5030.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
-
-
2"
2"
1 �"
2"
URINAL
URINAL (ADA)
UR-1
UR-2 1 �"
1 �"
SLOAN WATER FREE URINAL MODEL WES-1000, WALL HUNG, WALL OUTLET, VITREOUS CHINA, WHITE INCLUDING ONE PIECE WALL BRACKET WITH ANCHORS
WM-2
WM-1
WATER CLOSET
WATER CLOSET (ADA)
WC-1
WC-2
WF-1
SAME AS UR-1, MOUNT PER ADA REQUIREMENTS
SEE PLANS SEE PLANS
TMV-1
TP-1
TP-2
TMV-2
SI-1
NEPTUNE MODEL T-10, FLANGED ENDS, WITH TRICON E3 TRANSMITTER AND SMARTROL INSTRUMENTATION INCLUDING JENSEN MODEL K45-FH48-08T 4’-0" BY 5’-0" BY 47" PRECAST TRAFFIC VAULT-1-1/2"
NEPTUNE MODEL T-10, FLANGED ENDS, WITH TRICON E3 TRANSMITTER AND SMARTROL INSTRUMENTATION INCLUDING JENSEN MODEL K45-FH48-08T 4’-0" BY 5’-0" BY 47" PRECAST TRAFFIC VAULT2" -
SAME AS WC-1, MOUNT PER ADA REQUIREMENTS
BRADLEY 36" SEMI-CIRCULAR WASH FOUNTAIN WITH 9" DEEP BOWL MODEL WF2703-A-STD-F-PSD-TMA-MPSD, STAINLESS STEEL, OFF-LINE VENT WITH SUPPLIES FROM BELOW, STANDARD HEIGHT, FOOT CONTROL VALVE, POWDERED SOAP DISPENSER, THERMOSTATIC MIXING VALVE AND METAL-CLAD POWDERED SOAP DISPENSER
WATER METER
1"
1"
1" 1"
WATER METER
THERMOSTATIC MIXING VALVE
TRAP PRIMER �"
TRAP PRIMER �"
THERMOSTATIC MIXING VALVE 1"
WASH FOUNTAIN
2"SAND INTERCEPTOR
1 �"
�"(140 DEG F INLET) 3/4"(120 DEG F OUTLET)
SLOAN MODEL WETS 2050.1001-1.28 ELONGATED FLUSH VALVE VITREOUS CHINA TOILET, LOW-CONSUMPTION ROYAL MODEL 111-1.28 FLUSHOMETER WITH 1.28 GPF, WALL HUNG, WHITE, TOP SPUD INCLUDING MOUNTING HARDWARE, COMPLETE WITH BEMIS MODEL 1955C WHITE OPEN FRONT SEAT LESS COVER AND J.R. SMITH SERIES 0200 ADJUSTABLE FIXTURE SUPPORT
2"
2"
DESCRIPTION
BACKFLOW PREVENTER
CONDENSATE DRAIN FUNNEL
BACKFLOW PREVENTER
CALIBRATED BALANCE VALVE(CIRCUIT SETTER)
ELECTRIC WATER COOLER
EMERGENCY EYEWASH
SLOAN VACUUM BREAKER TRAP PRIMER MODEL VBF-72-A1
POWERS HYDROGUARD MODEL LFSH1432-11; STANDARD ROUGH BRASS FINISH WITH TEMPERATURE/ PRESSURE GAGE ON OUTLET,19 GPM FLOW RATE (WITH A 1 GPM MINIMUM FLOW RATE) AT 5 PSI PRESSURE DROP ACROSS THE VALVE
J.R. SMITH RIGURE 881120-E-U SAND INTERCEPTOR WITH REQUIRED EXTENSION, NO-HUB ADAPTOR, VANDAL PROOF SCREWS, SECURED GRATE, AND DUCTILE IRON SLOTTED GRATE (LOAD CLASS H20)
POWERS HYDROGUARD MODEL LFSH1434-13, STANDARD ROUGH BRASS FINISH WITH TEMPERATURE/ PRESSURE GAGE ON OUTLET, 42 GPM FLOW RATE (WITH A 1 GPM MINIMUM FLOW RATE) AT 5 PSI PRESSURE DROP ACROSS THE VALVE
PRECISION PLUMBING PRODUCTS PR-500 PRIME RITE TRAP PRIMER VALVE WITH DISTRIBUTION UNIT AS REQUIRED; PROVIDE TRAP PRIMER AIR GAP MODEL AG-500 FITTING DOWNSTREAM OF TRAP PRIMER VALVE
2"
4"
2"
2"
SYMBOL REMARKS
BFP-1
CWVENT
CBV-1
CDF-1
BFP-2 1 �"
VARIES
EWC-1 �"
EEW-1
2�"
1 �"
2"
1 �"
1 �"
1 �"
6" 3"
AREA DRAIN 2"AD-1
-
-
�"
4"
4"
2"
4"
4"
�" (TO INSTANTANEUS WATER HEATER)
SHOWER
SHOWER (ADA)
SH-1
SH-2
�"
�"
FD-1
FD-2
FS-1
FWD-1
ESE-1
LAVATORY (ADA) �"1 �"L-1
1 �"
�"
WILKINS MODEL 375-AG REDUCED PRESSURE PRINCIPLE ASSEMBLY WITH FULL PORT BALL VALVES, AIR GAP, AND QUICK TEST FITTING SET
BELL AND GOSSETT MODEL CB SERIES WITH NPT CONNECTIONS; � CB FOR �" HWR (115 DEG F AND 135 DEG F) AND CB-1 FOR 1" HWR (135 DEG F)
J.R. SMITH FIGURE 3821T DUCO CAST IRON WITH ACID RESISTANT COATED INTERIOR AND EXTERIOR INCLUDING FRONT CLEANOUT AND FIGURE 2646Y NO-HUB ADAPTOR
ACORN MODEL A112408S-FG-VR-CSC3-WF1, BARRIER FREE, FRONT PUSH-PADS, 14 GAGE STAINLESS STEEL TOP, BI-LEVEL, WALL MOUNTED, 1-MICRON STRAINER, CONCEALED SUPPORT CARRIER, 8.0 GPH, 400 WATTS, 4.8 FULL LOAD AMPERES, 120VOLTS/1 PHASE/60 HERTZ; 95 LBS SHIPPING WEIGHT
ACORN MODEL S034-FPB-SDC PEDESTAL MOUNTED EYE/FACE WASH STAINLESS STEEL BOWL, FROST PROOF BURY, STAINLESS STEEL DUST COVER, COMPLETE WITH MODEL S0000FLW2 FLOW SWITCH, MODEL S0000-AL2 ELECTRIC ALARM WITH FLASHING LIGHT AND HORN, MODEL S0000-HFC HAND FOOT CONTROL, MODEL S0000-IWH1 INSTANTANEOUS WATER HEATER, AND MODEL S0000-TMBI THERMOSTATIC MIXING VALVE
WILKINS MODEL 375XL REDUCED PRESSURE PRINCIPLE ASSEMBLY WITH NON RISING STEM SHUT-OFF VALVES, AIR GAP, AND QUICK TEST FITTING SET
�"
1"
PIPESERVICE FITTINGS REMARKS
DOMESTIC
WATER
SYSTEM
INDUSTRIAL
COLD WATER
SOIL, WASTE,
AND VENT
TRAP
PRIMING
HARD DRAWN COPPER TUBING,
ASTM B88
SEAMLESS COPPER TUBING,
TYPE M, HARD DRAWN, ASTM
B88
SEAMLESS COPPER TUBING,
TYPE K, SOFT ANNEALED,
ASTM B88
TRAP PRIMER PIPING SHALL BE SOFT DRAWN
TYPE K WATER TUBING WITHOUT FITTINGS
SOIL, WASTE,
AND VENTABOVE FLOOR USE
ABOVE FLOOR USE
SEAMLESS COPPER TUBING,
TYPE L HARD DRAWN, ASTM
B88
INDIRECT
DRAIN
SEAMLESS COPPER TUBING,
TYPE M, HARD DRAWN, ASTM
B88
ABOVE FLOOR USE
WROUGHT COPPER FITTINGS ASTM B16.22 OR
CAST COPPER ASTM B16.18 WITH 95-5
SOLDER JOINTS
ABOVE FLOOR USE
REMARKS
CIRCULATING PUMP SCHEDULE (BASIS OF DESIGN)
PHASEVOLTAGEPOWER,
HP
MOTOR DATA
115 1 4
DESCRIPTIONITEM
CIRCULATING
PUMP
MAKE AND MODEL
NUMBER
TACO PUMP
MODEL 2400-10S
FLA
1.4
EXPANSION TANK SCHEDULE (BASIS OF DESIGN)
22
ITEM DESCRIPTION
EXPANSION TANK
LOCATIONMAKE AND MODEL
NUMBERREMARKS
LOCATION
24
INLINE MOUNTING, PROVIDE TWO CLEVIS STYLE PIPE HANGERS AT INLET AND OUTLET OF PUMP.
REMARKS:
REMARKS:
2.1
1
1
1
2
1 3
2
ITEM
TEMP.
OUT
(°F)
REMARKSLOCATION
MAKE AND
MODEL
NUMBER
80 50 140
TEMPERATURE & PRESSURE GAUGE.
REMARKS:
NSF CONTRUCTION.MOUNT ON HOUSEKEEPING PAD.
1 2 3 4 5
1
2
3
4
5
REMARKSDIAMETER
3.25"
HEIGHTPIPE
SIZEUNITS
FIXTURE
2.62"
61-113
114-154
1-11
33-60
12-32
155-330
WATER HAMMER ARRESTER SCHEDULE (BASIS OF DESIGN)
DESIGNATION
2.97"
MODEL NUMBER
MAKE AND
J. R. SMITH 5005 34"
1"
3.59"
5.14"
5.52"
6.67"
3.25"J. R. SMITH 5010
1" 3.25"J. R. SMITH 5020
1" 3.25"J. R. SMITH 5030
1" 3.25"J. R. SMITH 5040
1" 3.25"J. R. SMITH 5050
PLUMBING FIXTURE CONNECTION SCHEDULE (BASIS OF DESIGN)PIPE MATERIAL SCHEDULE (BASIS OF DESIGN)
STORAGE
(GALLON)
TEMP.
IN
(°F)
SIZE
(INCH)
2ET-1
CP-1
FLOW
(GPM)
HEAD
(FEET)
CONN
SIZE
(INCH)
TANK
VOLUME
(GALLON)
ACCEPTANCE
VOLUME
(GALLON)
WEIGHT
(POUND)
WHA-A
WHA-B
WHA-C
WHA-D
WHA-E
WHA-F
FLOOR DRAIN
FLOOR DRAIN
FLOOR SINK
FOOD WASTE DISPOSER
S OR W
ABOVE FLOOR USE
34" MALE CONNECTION, AIR PRE-CHARGE SET @ 48 PSI.
NO-HUB CAST IRON SOIL PIPE
ASTM A 888 OR CISPI 301
CAST IRON NO-HUB TYPE PIPE FITTINGS
WITH STAINLESS STEEL COUPLING CISPI 310
AND NEOPRENE SEALING SLEEVE ASTM C
564 JOINTS
GREASE
WASTE AND
VENT
GREASE
WASTE AND
VENT
NO-HUB CAST IRON SOIL PIPE
ASTM A 888 OR CISPI 301
NO-HUB CAST IRON SOIL PIPE
ASTM A 888 OR CISPI 301
CAST IRON NO-HUB TYPE PIPE FITTINGS
WITH STAINLESS STEEL COUPLING CISPI 310
AND NEOPRENE SEALING SLEEVE ASTM C
564 JOINTS
INDUSTRIAL
(WASTE)
VENT
COMPRESSED
AIR PIPING
SCHEDULE 40 BLACK STEEL
ASTM A 53
SCHEDULE 40 CARBON STEEL
ASTM A 53
LUBE OIL,
GREASE, AND
ATF
ABOVE FLOOR USE
CAST IRON NO-HUB TYPE PIPE FITTINGS
WITH STAINLESS STEEL COUPLING CISPI 310
AND NEOPRENE SEALING SLEEVE ASTM C
564 JOINTS
CP-3CIRCULATING
PUMP
OMS
MECH B103
TACO PUMP
MODEL 0014-SF11.55 115 1 1 22
34
FLANGE 1 2
CP-2CIRCULATING
PUMP
ARC
MECH A117
TACO PUMP
MODEL 0011-SF41.76 115 1 1 31
34
FLANGE 1 2
ARC
MECH A117
RPM
3450
3450
3
4"(IW)
OMS
MECH B103
INDUSTRIAL
WASTE AND
VENT
MALLEABLE IRON THREADED FITTINGS ASME B
16.3 WITH THREAD COMPOUNDS (APPLY
COMPOUND ON MALE THREADS ONLY,
COMPOUND SHALL BE COMPATIBLE WITH TYPE
OF SERVICE)
MALLEABLE IRON THREADED FITTINGS ASME
B 16.3 WITH THREADS COMPOUNDS (APPLY
COMPOUND ON MALE THREADS ONLY,
COMPOUND SHALL BE COMPATIBLE WITH
TYPE OF SERVICE)
WROUGHT COPPER FITTINGS ASTM B16.22 OR
CAST COPPER ASTM B16.18 WITH 50-50
SOLDER JOINTS
CONDENSATE
DRAIN
(PUMP)
CONDENSATE
DRAIN
(GRAVITY)
COPPER DRAINAGE TUBE ASTM
B 306
EMERGENCY SHOWER AND EYEWASH(COMBINATION UNIT)
SERVICE WEIGHT CAST IRON
HUB AND SPIGOT SOIL PIPE,
ASTM A74
SERVICE WEIGHT CAST IRON
HUB AND SPIGOT SOIL PIPE,
ASTM A74
SERVICE WEIGHT CAST IRON
HUB AND SPIGOT SOIL PIPE,
ASTM A74
CAST IRON HUB AND SPIGOT FITTINGS WITH
NEOPRENE RUBBER GASKET JOINTS, CISPI
HSN-85
CAST IRON HUB AND SPIGOT FITTINGS WITH
NEOPRENE RUBBER GASKET JOINTS, CISPI
HSN-85
CAST IRON HUB AND SPIGOT FITTINGS WITH
NEOPRENE RUBBER GASKET JOINTS, CISPI
HSN-85
WROUGHT COPPER FITTINGS ASTM B16.22 OR
CAST COPPER ASTM B16.18 WITH 95-5
SOLDER JOINTS AND INSULATION
ABOVE FLOOR USE; UNDERGROUND USE WITH PIPE WRAP FOR SOIL
CORROSIVITY PROTECTION
CAST BRONZE DRAINAGE FITTINGS ASTM B
16.23 WITH 50-50 SOLDER JOINTS AND
INSULATION
ABOVE FLOOR USE
WROGHT COPPER OR CAST COPPER DWV
FITTINGS WITH SOLDER JOINTS AND
INSULATION
ABOVE FLOOR USE
LUBE OIL,
GREASE, AND
ATF
ASTM A240 316 SERIES
STAINLESS STEEL PRIMARY
PIPE WITH NYLON 12 OUTER
JACKET AND EFEP
SECONDARY BARRIER
UNDER FLOOR AND UNDERGROUND
USE FOR DWH-1
WATTS
DETA 5
10" DIAMETER BY
14" HIGH3.5
1/101
FLANGE 4
1/8
1/8
STAINLESS STEEL CONSTRUCTION: PROVIDE WITH TACO AQUASTAT MODEL 563-2 OR APPROVED EQUAL.
STAINLESS STEEL CONSTRUCTION: PROVIDE WITH HONEYWELL AQUASTAT MODEL L6006C1018 OR APPROVED EQUAL.
4 MODEL 110-252SF COMPANION FLANGE SET
PROVIDE ACCESS PANEL
PROVIDE ACCESS PANEL
PROVIDE ACCESS PANEL
PROVIDE ACCESS PANEL
PROVIDE ACCESS PANEL
PROVIDE ACCESS PANEL
OMS
MECH B103
A.D.SMITH
MODEL SACE80-36
TEMPERATURE & PRESSURE RELIEF VALVE SIZED TO ASME SPECIFICATIONS
(RUN DRAIN TO NEAREST FLOOR SINK WITH 1" AIRGAP).
6 SOLAR WATER HEATING SYSTEM.
BUILDING UNDERFLOOR AND UNDERGROUND (UP TO 5 FEET
OUTSIDE THE BUILDING) USE
BUILDING UNDERFLOOR AND UNDERGROUND (UP TO 5 FEET
OUTSIDE THE BUILDING) USE
BUILDING UNDERFLOOR AND UNDERGROUND (UP TO 5 FEET
OUTSIDE THE BUILDING) USE
ABOVE FLOOR USE AND BUILDING UNDER FLOOR USE WITH PIPE
WRAP FOR SOIL CORROSIVITY PROTECTION
PROVIDE WATTS WATER HEATER
SEISMIC RESTRAINT OR APPROVED
EQUAL.
TYPE L FOR ABOVE FLOOR USE (HOT AND COLD WATER INCLUDING
SOFT WATER AND TEPID WATER WITH INSULATION) AND TYPE K FOR
UNDER FLOOR AND UNDERGROUND USE WITH PIPE WRAP FOR SOIL
CORROSIVITY PROTECTION
C.
KO
RP
AS
H
166
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
SC
HE
DU
LES
PLU
MBIN
G
P-6010
07-2
8-1
1
M.
BE
TZ
LC
AR
C_P-6
010.d
gn
1 �" (TO MIXING VALVE)
1 �" (TO MIXING VALVE)
1 �" (TW TO UNIT)
1 �" (140ÉF INLET) 1 �" (120ÉFOUTLET)
OIL-WATER SEPARATOR(SEE CIVIL DWG CU-124 FOR LOCATION)
GREASE INTERCEPTOR (SEE CIVIL DWG CU-124 FOR LOCATION)
MODEL
MANUFACT.
1
WATER TREATMENT SCHEDULE
UNIT
NOAND
COIL PIPE ASSEMBLY
PIPE
SIZE
PIPE
MATERIAL
DIMENSION
DIAMETER
DIMENSION
LENGTH
COIL
WEIGHT
LBS
ELECTRICAL
VOLTAGE VA
120V/60/1
ENCLOSURE
DIMENSION
PANEL
WEIGHT
LBS
32
REMARKS
1 2 3 4
2
3
PROVIDE WITH EXTENSION OF UMBILICAL CABLE THAT EXTENDS TO 25 FEET IN LENGTH
28
TRANSFORMER/SIGNAL GENERATOR PANEL
10"x10"x8"
PROVIDE WITH NEMA 3R TRANSFORMER AND SIGNAL GENERATOR PANEL AS SPECIFIED
4 TREATMENT MODULE/COIL SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURERS INSTRUCTIONS AND MINIMUM
39.5"
OF 3 FEET CLEAR OF ALL MOTORS, PUMPS, FANS AND HIGH VOLTAGE EQUIPMENT.
3" 9" 405
COIL PIPE ASSEMBLY SHALL BE ENGINEERED INTO PIPING CONFIGURATION AND SHALL INCLUDE FLANGED ENDS.
CLEARWATER
DOLPHIN
G3030PVC
PVC
SCHED. 8
J.R. SMITH FIGURE 2005Y-NB-P050, NO HUB OUTLET, DUCO CAST IRON BODY AND FLASHING COLLAR, 6" ROUND ADJUSTABLE NICKEL BRONZE LOW DOME STRAINER, AND 1/2" TRAP PRIMER CONNECTION
SYMMONS C-96-300-B30-V-X-QD TEMPTROL SHOWER SYSTEM WITH HAND SPRAY,PRESSURE BALANCING MIXING VALVE, LEVER HANDLE, CHROME PLATED, WALL/HAND SHOWER WITH FLEXIBLEMETAL HOSE, VACUUM BREAKER, QUICK DISCONNECT HAND SPRAY UNIT AND 30" SLIDE BAR WITH OMNI MODEL A-710-2.00VR INLINE FLOW CONTROL
MOP SINK
MOP SINK
MS-1 3"
MS-2 3"
�"
SHOWER DRAINSHD-1 2"
KOHLER "CAXTON" MODEL K-2210, WHITE, VITREOUS CHINA, UNDERCOUNTER MOUNTED, FRONT OVERFLOW, WITH KOHLER K-8998 CHROME PLATED P-TRAP, COMPLETE WITH SYMMONS SYMMETRIX LAVATORY FAUCET MODEL S-20-2-G-.5 WITH GRID STRAINER DRAIN AND VANDAL RESISTANT 0.5 GPM FLOW RESTRICTOR, BRASSCRAFT COMPRESSION INLET SUPPLY KIT MODEL KTCR19B16A C; PROVIDE WATER AND DRAIN ADA INSULATION KIT
HB-1
MV-1
HB-2
SYMMONS C-96-1-X TEMPTROL SHOWER SYSTEM, PRESSURE BALANCING MIXING VALVE, LEVER HANDLE, CHROME PLATED, WITH OMNI MODEL A-752-2.00-VR FLOW CONTROL SHOWER HEAD
J.R. SMITH FIGURE 3100Y-12-FBS-L, NO HUB OUTLET, SECURED NICKEL BRONZE RIM AND � GRATE, ALUMINUM FLAT BOTTOM STRAINER, AND SPEEDI-SET SERVICE WEIGHT
J.R. SMITH FIGURE 2005Y-CP-P050, NO HUB OUTLET, 6" SQUARE ADJUSTABLE CHROME PLATED STRAINER AND 1/2" TRAP PRIMER CONECTION
J.R. SMITH FIGURE 2110Y-L-P050, NO HUB OUTLET, DUCO CAST IRON BODY AND FLASHING COLLAR WITH CAST IRON BAR GRATE, ROUND TOP, SPEEDI-SET SERVICE WEIGHT, AND �"TRAP PRIMER CONNECTION
IN SINK ERATOR EVOLUTION COMPACT; 3/4 HP, 120 VOLT/1 PHASE/ 60 HERTZ, 8.1 AMPERE LOAD
HAWS MODEL 8330 WITH MODEL 9001 EMERGENCY ALARM AND LIGHT SYSTEM, (120 VAC, 60 CYCLES), MODEL 9201 TEMPERED WATER BLENDING SYSTEM, AND UNIVERSAL SIGN
JENSEN MODEL JP1200-EE-G, TRAFFIC RATED, WITH MODEL 2432-Z SAMPLE BOX WITH PIPE CONNECTORS AND TRAFFIC CAST IRON FRAME AND COVER WITH GASKETS INCLUDING REQUIRED RISERS
WOODFORD FREEZELESS ANTI-SIPHON WALL FAUCET MODEL 19
�"
�"
J.R. SMITH FIGURE 2005Y-CP, NO-HUB OUTLET, 6" SQUARE ADJUSTABLE CHROME PLATED STRAINER
�"
MIXING VALVE
�"
�" COMPRESSION
3/8"(140 DEG F INLET) 3/8"(120 DEG F OUTLET)COMPRESSION
HOSE BIBB (WASH PLATFORM)
HOSE BIBB (MECH RM & OMS EXTERIOR)
�" (TW)
1 �"
SK-1 �"
KOHLER "BANNON" MODEL K-6716 MOP SINK, CAST IRON, ACID RESISTANT ENAMEL, SINGLE COMPARTMENT, WALL MOUNTED, WHITE, RIM GUARD, WITH KOHLER K-6673 3" TRAP, COMPLETE WITH KOHLER "KNOXFORD" MODEL K-8906 FAUCET, 8" CENTERS, LEVER HANDLES, VACUUM BREAKER, LOOSE KEY STOPS IN SHANKS, PAIL HOOK, THREADED HOSE CONNECTION SPOUT, AND POLISHED CHROME FINISH; PROVIDE OMNI INLINE FLOW CONTROL MODEL A-810-2.00-VR AT FAUCET OUTLET
KOHLER "WHITBY" MODEL K-6710 MOP SINK, CAST IRON, ACID RESISTANT ENAMEL, CORNER SINK, FLOOR MOUNTED, WHITE, K-8940 COATED WIRE RIM GUARD, WITH KOHLER "KINLOCK" MODEL K-8908 FAUCET, 8" CENTERS, LEVER HANDLES, VACUUM BREAKER, LOOSE KEY STOPS IN SHANKS, WALL BRACE, PAIL HOOK, THREADED HOSE CONNECTION SPOUT, AND POLISHED CHROME FINISH; PROVIDE OMNI INLINE FLOW CONTROL MODEL A-810-2.00-VR AT FAUCET OUTLET
DOMESTIC WATER HEATER (ELECTRIC) SCHEDULE (BASIS OF DESIGN)
HW
DWH-1
WT-1
2"
2"
ELKAY MODEL LRAD1918 TOP MOUNT SINGLE COMPARTMENT SINK 19"x18"x6" DEEP, OFF-CENTERED REAR DRAIN, WITH THREE 1�" DIAMETER FAUCET HOLES; SYMMONS VELLA MODEL S-2610 CHROME FINISH KITCHEN FAUCET WITH DECK PLATE FOR 3-HOLE INSTALLATION, SINGLE HANDLE WITH PULL-OUT SPRAY SPOUT, INTEGRAL VACUUM BREAKER AND 1.5 GPM FLOW; BRASSCRAFT COMPRESSION INLET SUPPLY KIT MODEL KTCR19B20A C
SINK
POWERS MODEL LFe480-11 TEMPERING VALVE, ROUGH CHROME FINISH
JENSEN MODEL JP320-EE-SO, TRAFFIC RATED WITH MODEL 2432-Z SAMPLE BOX WITH PIPE CONNECTORS AND TRAFFIC CAST IRON FRAME AND COVER WITH GASKETS INCLUDING REQUIRED RISERS
WOODFORD MODEL S4H BACKFLOW PROTECTED, AUTOMATED DRAINING, FREEZELESS SELF CLOSING, SANITARY YARD HYDRANT.
2"
�"2"
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
SHEET
REFERENCE
NUMBER:
2
9:2
9:4
4
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-6010.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
Dw
n by:
Desig
ned by:
Revie
wed by:
Date:
Rev.
Ckd by:
US Army Corps
of Engineers
Sub
mitted by:
Descriptio
nDescriptio
n
A
Mark
B
D
21 4 5
4 51
C
LOUISVILLE DISTRICT
LO
UIS
VIL
LE
DIS
TRIC
T
*** Safety Pays ***
*** Support Value Engineering - It Pays ***
Date
Appr.
Mark
Appr.
Date
Plot scale:
Plot date:
File na
me:
7/2
2/2
011
U.S.
AR
MY
CO
RP
S
OF
EN
GIN
EE
RS
Sheet of
4
HU
TT
ON
CE
NT
RE
DRIV
E,
SUIT
E 800
SA
NT
A
AN
A,
CA
LIF
OR
NIA 92707
TE
L (7
14) 327-1600
FA
X (7
14) 327-1601
SHEET
REFERENCE
NUMBER:
2
9:3
0:1
3
AM
7/22/2011
moraja
c:\
pw
workin
g\
gbna\
moraja\
dm
s97
639\
LC
AR
C_
P-6020.d
gn
LO
UIS
VIL
LE,
KE
NT
UC
KY
U.S.
AR
MY
RE
SE
RV
E
CE
NT
ER
LA
S
CR
UC
ES,
NE
W
ME
XIC
O
222
F-17
1-4
0-160
Project C
ode:
Solicitatio
n
No.
CERTIFIED FINAL SUBMITTAL (RTA) - 07-28-11
W912
QR-11-
R-007
1
11 INCH
W.C.
C.
KO
RP
AS
H
167
J.
ON
GL
AO
I. F
RA
NC
O
J.
ON
GL
AO
SC
HE
DU
LES
PLU
MBIN
G
P-6020
07-2
8-1
1
M.
BE
TZ
LC
AR
C_P-6
020.d
gn
11 INCH
W.C.
ITEM REMARKS
MAKE AND
MODEL
NUMBER
1
SERVICE
LOCATIONDESCRIPTION
PIPE SIZE
CONNECTION.
INCH
CONNECTION
TYPE
ORIFICE
SIZE.
INCH
VALVE
ANGLE,
DEGREE
MAXIMUM
INLET
PRESSURE
MINIMUM
INLET
PRESSURE
OUTLET
PRESSURE
SETPOINT
MAXIMUM
CAPACITY,
CFH
REQUIRED
CAPACITY,
CFH
SPRING
NUMBER
SPRING
COLOR
VENT
SIZE,
INCH
2 - - - - - - -EARTHQUAKE VALVEPACIFIC SEISMIC
MODEL 314THREADED 3,240 1,4495 PSI
SEE DWG
CU-124
FOR LOCATION
NATURAL GAS METER PRESSURE REGULATOR AND SEISMIC VALVE SCHEDULE (BASIS OF DESIGN)
12 - - - - - - -EARTHQUAKE VALVEPACIFIC SEISMIC
MODEL 314THREADED 3,2405 PSI
1- - - - - - -EARTHQUAKE VALVE THREADED 1,9955 PSIPACIFIC SEISMIC
MODEL 303(7)1-1/2
923
526
EQV-1
EQV-2
EQV-3
REMARKS
BOTTLE FREE WATER CO.
MODEL BFW6518WS2DUPS
WITH BFW4830BT
BOTTLE FREE WATER CO.
MODEL BFW521295S WITH
BFW4018BT
53 GPM @ 15 PSI
PRESSURE DROP
22 GPM @ 15 PSI
PRESSURE DROP
11 INCH
W.C.
11 INCH
W.C.
ARC (OUTSIDE
MECH A117)
3
CONTINUOUS SERVICE FLOW RATE OF
40 GPM TO DOMESTIC HOT WATER SYSTEM;
1,150 POUNDS SALT CAPACITY
REMARKS:
1
2
D.0036 PSI (0.1 INCH W.C.) PRESSURE DROP
EQUIPMENT SELECTION IS BASED ON 0.6 SPECIFIC GRAVITY OF NATURAL GAS.
3
4
0.55 INCH W.C. PRESSURE DROP @ 923 CFH FLOW.
0.40 INCH W.C. PRESSURE DROP @ 523 CFH FLOW.
OMS (OUTSIDE
MECH B103)
ARC (OUTSIDE
MECH A117)-
- 4
22 10 1GAS PRESSURE
REGULATOR
ARC (OUTSIDE
MECH A117)
SENSUS METERING
MODEL 243-8-2THREADED 3/8 1,750 923 143-82-021-02
GREEN-
BLACK5 PSI 4 PSIGPR-1
LOCATIONITEMSUPPLIER AND
MODEL NUMBERDIMENSIONS
ELECTRICAL REQUIREMENTS
PEAKFLOW RATE
WS-1
WS-2
ARC
MECH A122
OMS
MECH B103
72" WIDE BY
32" DEEP
BY 78" HIGH
110/1/60
(DUPLEX OUTLET)
110/1/60
(QUAD OUTLET)
2-GAS PRESSURE
REGULATOR
OMS (OUTSIDE
MECH B103)
SENSUS METERING
MODEL 143-80-21 1/4 THREADED 1/4 890 526 143-52-021-17 GREEN 3/4
REMARKSSYMBOL
VOLTS PHASEHERTZHP
MOTOR ELECTRICAL DATA
LOCATION TYPECAPACITY
ICFM
WORKINGPRESSURE
PSIG
MOTORSPEED
RPM
DISCH.CONN.(INCH)
AC-1
1
1OMS
MECH B103
5 PSI 4 PSI
MAKE AND MODEL
-OMS (OUTSIDE
MECH B103)THREADEDGAS METER
SENSUS METERING
SONIX 600- -
50" WIDE BY
20" DEEP
BY 61" HIGH
CONTINUOUS SERVICE FLOW RATE OF
15 GPM TO DOMESTIC HOT WATER SYSTEM;
400 POUNDS SALT CAPACITY
WATER SOFTENER (BASIS OF DESIGN)
GPR-2
AIR COMPRESSOR SCHEDULE (BASIS OF DESIGN)
SPEEDAIRE
MODEL 1WD7434.8 125 740 10 60 3480 13.4
AMPERE
34 NPT 72
12L x 25W x 54H 810
RECEIVERCAPACITY(GALLONS)
120
REMARK:
DIMENSION (INCHES) WITH RECEIVER
SHIPPING WEIGHT(LBS)
TWO-STAGE PACKAGE
TYPE MOUNTED ON
HORIZONTAL RECEVER
SPLASH-LUBRICATED, CAST-IRON COMPRESSOR PUMPS WITH A FINNED INTERCOOLER, TOTALLY ENCLOSED SAFETY-DESIGNED BELT GUARD, OPEN DRIP PROOF NEMA MOTOR, COMPLY WITH CALIFORNIA CODE 462(L)(2), INCLUDING MOUNTED AND WIRED MAGNETIC MOTOR STARTER, INITIAL FILL OF COMPRESSOR OIL, AIR-COOLED AFTER COOLER, VIBRATION ISOLATORS, AUTOMATIC DRAIN, AND MAINTENANCE KIT NUMBER 1WF47.
GM-2
-THREADEDGAS METERSENSUS METERING
SONIX 880- - - - - - - -
- - - - - -
GM-1