Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 1
Pollution Incident
Response Management
Plan Port Macquarie – Hastings Council Waste Management Facilities
January 2020
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 2
REVISION HISTORY
No Issue Date Revision Notes Prepared By Approved By
1 August 2012
Initial development N. Julian T. Molloy
2 March 2013 Updates N. Julian T. Molloy
3 June 2013 Minor updates N. Julian T. Molloy
4 July 2013 Update N. Julian T. Molloy
5 September 2014
Updates
N. Julian T. Molloy
6 February 2015
Updates N. Julian T. Molloy
7 December 2015
Update N. Julian T. Molloy
8 October 2016
Update N. Julian G. Cameron
9 March 2017 Addition of Kew WTS S. McKinnon G. Cameron
10 March 2019 General updates for sites, contact details etc
N.Julian G. Cameron
11 May 2019 Update contact details S.McKinnon G.Cameron
12 July 2019
Added Figure 3 in Dunbogan
Added gas monitoring procedure
Amended PIRMP location at STP
Amended Dunbogan Evacuation SOP
S.McKinnon M. Magalhaes
13 October 2019
Updated Cairncross maps and pollutants
Added latest test dates
Updated contact details
S.McKinnon M. Magalhaes
14 October 2019
Updated Kew WTS with Hazardous Waste CRC details
Updated Kew WTS maps
S. Tracey M. Magalhaes
15 January 2020
Updated Council contact details and added in sign sheets
S. Tracey M. Magalhaes
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 3
By signing this form you acknowledge that you have read and understand the latest version of the Pollution Incident Response Management Plan.
Staff Name Date
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 4
PIRMP TESTING HISTORY
Site Latest Test Date Test Type Testing Officer
Cairncross WMF 23/01/2019 Mock Evacuation N. Julian
Port Macquarie WMF 06/03/2019 Mock Evacuation N. Julian
Dunbogan WMF N/A N/A N/A
Kew WMF 19/06/2019 Mock Evacuation N. Julian
Wauchope WMF 19/06/2019 Mock Evacuation N. Julian
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 5
TABLE OF CONTENTS
1 INTRODUCTION ..................................................................................................... 7
2 POLLUTION INCIDENT MANAGEMENT RESPONSE PLAN OBJECTIVES ......... 7
3 LEGISLATIVE REQUIREMENTS ............................................................................ 8
3.1 Definition of a ‘pollution incident’ 8
3.2 Contact details 8
4 POLLUTION INCIDENT RESPONSE MANAGEMENT PLANS .............................10
4.1 Availability of plans 10
4.2 Relationship with other emergency plans 10
4.3 Actions to be taken during or immediately after a pollution incident 10
4.4 Incident Critique 14
4.5 Review of the Pollution Incident Response Management Plan 14
4.6 Staff training 14
5 TESTING PLANS ...................................................................................................15
5.1 Plan Review 15
5.2 Testing 15
6 IMPLEMENTING PLANS .......................................................................................16
7 THE CAIRNCROSS WASTE MANAGEMENT FACILITY ......................................18
7.1 Maps 19
7.2 Communicating with neighbours and the local community 25
7.3 Minimising harm to persons on the premises 25
7.4 Site details 25
7.5 Description and likelihood of hazards 27
7.6 Pre-emptive actions to be taken 29
7.7 Inventory of pollutants on site 30
7.8 Safety equipment 32
8 THE PORT MACQUARIE WASTE MANAGEMENT FACILITY ..............................34
8.1 Maps 35
8.2 Contacts and communication 39
8.3 Communicating with neighbours and the local community 39
8.4 Minimising harm to persons on the premises 39
8.5 Site Details 39
8.6 Description and likelihood of hazards 40
8.7 Pre-emptive actions to be taken 42
8.8 Inventory of pollutants on site 43
8.9 Safety equipment 44
9 THE DUNBOGAN WASTE MANAGEMENT FACILITY .........................................46
9.1 Maps 47
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 6
9.2 Communicating with neighbours and the local community 50
9.3 Minimising harm to persons on the premises 50
9.4 Site Details 50
9.5 Description and likelihood of hazards 51
9.6 Pre-emptive actions to be taken 52
10 THE KEW WASTE MANAGEMENT FACILITY ......................................................54
10.1 Maps 55
10.2 Contacts and communication 58
10.3 Communicating with neighbours and the local community 58
10.4 Minimising harm to persons on the premises 58
10.5 Site Details 58
10.6 Description and likelihood of hazards 59
10.7 Pre-emptive actions to be taken 61
10.8 Inventory of pollutants on site 62
10.9 Safety equipment 63
11 THE WAUCHOPE WASTE TRANSFER STATION ................................................65
11.1 Contacts and communication 68
11.2 Communicating with neighbours and the local community 68
11.3 Minimising harm to persons on the premises 68
11.4 Site Details 68
11.5 Description and likelihood of hazards 69
11.6 Pre-emptive actions to be taken 71
11.7 Inventory of pollutants on site 72
11.8 Safety equipment 72
12 APPENDICES ........................................................................................................73
APPENDIX 1: Pollution incident response management plan Exercise Evaluation Form 73
APPENDIX 2: Standard Operating Procedures 74
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 7
1 INTRODUCTION
Changes to environment protection legislation took place in 2012, as a result of the Protection of the Environment Legislation Amendment Act 2011 (the Act). The changes related to the way that pollution incidents are reported and managed, and the new requirements have been integrated into this plan. The purpose of this Pollution Incident Response Management Plan (PIRMP) is to assist employees and management in making quality decisions during times of crisis. This plan contains guidance in determining the appropriate actions to take to prevent injury and damage to the environment and property due to a pollution incident. Incidents such as fire, vehicle crashes, chemical spills, explosion or gas leakages are controlled by Combat Agencies such the NSW Fire Brigade and Police. The responsible Combat Agency may request Council to provide assistance in the emergency. Other relevant authorities specified in the Act may also need to be notified (such as other Council staff, NSW Ministry of Health, SafeWork NSW, Fire and Rescue NSW).
2 POLLUTION INCIDENT MANAGEMENT RESPONSE PLAN OBJECTIVES
It is Port Macquarie-Hastings Council’s (PMHC) Waste Management Section’s intent to prevent all foreseeable pollution incidents through the implementation of standard operational procedures and the regular training of personnel in the implementation of operational procedures. However, it is recognized that pollution incidents are not totally preventable and this plan has been developed to achieve the following: To provide employees with procedures to follow for effective and safe actions during a pollution incident, including evacuation. Objectives of the plan are as follows:
To serve as the pollution incident management guide for employees and facility users in the event of an emergency;
To ensure the timely communication of the incident to all relevant authorities, and others who may be affected;
To provide standard operating procedures (SOP’s) which identify risks and provide planned actions to minimise and manage those risks. These SOPs will be implemented based upon the nature and extent of the emergency;
To identify responsible staff and carry out regular training to ensure that staff are able to carry out the plan;
To ensure regular testing of the plan itself for accuracy, currency and suitability. While no plan can take into consideration all possible scenarios, the SOP’s referred to in this plan should assist employees in making proper and appropriate decisions
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 8
3 LEGISLATIVE REQUIREMENTS
The Protection of the Environment Operations (General) Amendment (Pollution Incident Response Management Plans) Regulation 2012 requires all holders of an environment protection licence. Specific requirements for pollution incident response management plans are set out in Part 5.7A of the POEO Act and the Protection of the Environment Operations (General) Regulation 2009 (POEO(G) Regulation), to prepare, implement and test pollution incident management plans. The changes are described below:
Licensees are required to report pollution incidents immediately instead of “as soon as practicable” (section 148, POEO Act).
Licensees must notify all the relevant authorities about the incidents, not just the appropriate regulatory authority (ARA) under the POEO Act. These include the ARA, the Environment Protection Authority (EPA, if not the ARA), NSW Ministry of Health, the SafeWork Authority, the local authority (if not the ARA) and Fire and Rescue NSW.
3.1 Definition of a ‘pollution incident’
Definition of a ‘pollution incident’ (as described in Environmental Guidelines: Preparation of pollution incident response management plans; EPA 2012).
Pollution incident; means an incident or set of circumstances during or as a consequence of which there is likely to be a leak spill or other escape or deposit of a substance as a result of which pollution has occurred is occurring or is likely to occur. It includes an incident or set of circumstances in which a substance has been placed or disposed of on premises but it does not include an incident or set of circumstances involving only the emission of noise.
A Pollution Incident is required to be notified if there is risk of material harm to the environment, as defined below:
If it involves actual or potential harm to the health or safety of human beings or to ecosystems that is not trivial, Or
If results in actual or potential loss or property damage of an amount, or amounts in aggregate, exceeding $10,000 (or such other amount as is prescribed by the regulations), and
The loss includes the reasonable costs and expenses that would be incurred in taking all reasonable and practicable measures to prevent, mitigate or make good harm to the environment.
Notification is required even where ‘harm to the environment is caused only in the premises where the pollution incident occurs’, as specified in section 147(2).
Council is now required to report pollution incidents immediately to the EPA, NSW Health, Fire and Rescue NSW, SafeWork NSW and other sections of Council.
In the event of a leak or spill resulting in pollution, a conservative approach is required. Staff must inform the Waste Coordinator, Waste Manager or Group Manager Commercial Business Units of the spill.
3.2 Contact details
During a pollution incident, the Group Manager Commercial Business Units will ultimately have the responsibility for ensuring that proper actions are taken to ensure the safety of employees and facility users. In this regard the Group Manager Commercial Business Units will assume the role of the Pollution Incident Response Manager.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 9
In the event that the Group Manager Commercial Business Units is not available, the Waste Manager or Waste Coordinator will assume responsibility for incident management. During an emergency situation, roles and responsibilities will be as follows:
The on duty facility attendants (and contractors as described within this document) shall act as Area Wardens, or the Waste Coordinator will act as the Chief Warden.
In the absence of the Waste Coordinator, the on duty facility attendant will act as Chief Warden.
It is the role of the Chief Warden, and in his absence the Area Wardens, to activate and coordinate the evacuation of the site.
Table 1: Emergency contact details
EMERGENCY COMBAT AND SUPPORT AGENCY CONTACT DETAILS
Name Organisation Contact
NSW Fire Brigade Fire and Rescue NSW (reporting pollution) Port Macquarie Fire Station Wauchope Fire Station Laurieton Fire Station
000 or 1300 729 579 65810520 6585 2161 6559 9127
NSW Rural Fire Service Rural Fire Service – Mid North Coast Region
000 or 6588 9000
NSW Police Service Port Macquarie Police Station 000 or 6583 0199
NSW Ambulance Service
Port Macquarie Ambulance Station 131233
Environment Protection Agency (EPA)
Pollution Incidents – Environment Line 131 555
Coffs Harbour Regional Office 6659 8298
NSW Department of Health
Mid North Coast Local Health District Port Macquarie Office
1800 726 997
SafeWork Authority Port Macquarie Office 24 hour hotline
6588 7000 131050
National Parks and Wildlife Services (NP&WS)
Parks and Wildlife Mid North Coast Regional Office
6588 5555
Local Hospital Port Macquarie Base Hospital 02 5524 2000
Department of Primary Industries (NSW Fisheries)
Port Macquarie Office (Acacia Ave) 5524 0600
Poisons Information Hotline
Westmead Hospital 131126
State Emergency Service
Port Macquarie SES (General) Flood and Storm
6581 0150 132 500
Department of Families and Community Services
Port Macquarie Community Services 6583 3622
Roads & Maritime Services
Port Macquarie District Office 132213
Bureau of Meteorology Land weather and flood warnings NSW 02 9296 1555
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 10
Table 2: Council Staff Contact Details
COUNCIL WASTE STAFF
Position Name Mobile Contact Contact
Group Manager Commercial Business Units
Ashley Grummitt 0403 361 610 6581 8043
Waste Manager Michael Magalhaes
0438 667 492 6581 8125
Waste Services Coordinator Wayne Lenard 0407 417 414 6581 8076
Relieving Waste Services Coordinator/ Team Leader Cairncross
Andrew Collins 0419 419 690 -
Weighbridge Attendants Cairncross Glenn Twaddell Paul Cini
- 6585 0738
Waste Transfer Station Attendants Port Macquarie
Paul Dymock Craig Smith
6581 4817
Kew Waste Facility Attendants Colin Applegate Steve Watson
6559 5741
Weighbridge Attendants Wauchope Terry Jefferies Ray Cheeseman Anthony Magnoli
6581 4817 -
COUNCIL HUMAN RESOURCES STAFF
Safety Coordinator Graham Chandler 0400 818 867 6581 8601
Employee Relations Officer Brenna Southwell - 6581 8606
4 POLLUTION INCIDENT RESPONSE MANAGEMENT PLANS
Pollution Incident Response Management Plans will assist employees and management in making quality decisions during times of crisis. Plans contain guidance in determining the appropriate actions to take to prevent injury and damage to the environment and property due to a pollution incident.
4.1 Availability of plans
The PIRMP will be available in printed form at each Waste Facility, with a master copy being maintained by the Group Manager Commercial Business Units. A copy of the plan shall also be carried within the vehicles of the Group Manager Commercial Business Units, the Waste Manager and Waste Coordinator at all times. A copy of the plan shall also be provided to Council’s Safety Coordinator (Human Resources section). The plan will be available for review by all employees and will be available on the PMHC website. Plans will be available to an authorised EPA officer on request.
4.2 Relationship with other emergency plans
Associated documents:
Facility Operational Environmental Management Plans (OEMPs)
Solid waste management – Waste Policies, SOPs and Safe Work Method Statements
4.3 Actions to be taken during or immediately after a pollution incident
Firstly, call 000 if the incident presents an immediate threat to human health or property. Fire and Rescue NSW, the NSW Police and the NSW Ambulance Service are the first responders, and are responsible for controlling and containing incidents.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 11
If the incident does not require an initial combat agency, or once the 000 call has been made, notify the relevant authorities as per the contact list on the previous page. Authorities required to be informed are highlighted, in Table 1 and should be contacted in descending order. Complying with these notification requirements does not remove the need to comply with any other obligations for incident notification, for example, those that apply under other environment protection legislation or legislation administered by SafeWork. Council’s Safety Coordinator needs to be contacted in the event of an incident. Should a staff member or contractor be injured Council’s Workers Compensation Officer needs to be informed as soon as possible after the incident has occurred.
4.3.1 Emergency descriptions
A. First Aid Emergency:
Area to be supervised/managed, NOT evacuated. Minor Incident only.
B. Minor Emergency:
Area ONLY to be evacuated (eg cardiac arrest or other injury requiring ambulance, minor
vehicle incident on site, small spill etc).
C. Major Emergency:
The ENTIRE premises to be evacuated (eg fire, large chemical release).
Refer to SOP 17 - PMHC Solid Waste Management policies, Waste SOPS and Safe Work
Method Statements 2017 for further detail.
4.3.2 Small Area/Minor Emergency or Incidents (B) Incidents such as small chemical spills will generally not require the notification of emergency combat agencies. HOWEVER it will be general practice that ALL incidents will be notified immediately to the Group Manager Commercial Business Units and the Safety Coordinator, so that an assessment of the level of response can be made. The telephone (landline and/or mobile) will be the preferred means of reporting such emergencies. In addition to the immediate notification of any minor incident or event, a PMHC Injury and Incident Report Form, is to be completed and forwarded to the Group Manager Commercial Business Units.
4.3.3 Serious (Major) or Facility Wide Emergency Situation (C) Serious and/or facility wide emergency situations include incidents such as a fire or explosion, medium to large chemical spill or gas releases which require the assistance/involvement of Emergency Combat Agencies (NSW Fire Service, Police, Ambulance) and/or Supporting Agencies (EPA/SafeWork). These must be attended to using relevant SOPs. Reporting must be carried out as required (see Table 1). Where serious incidents/events occur the following notification procedures are to be initiated immediately.
(a) The Chief Warden is to IMMEDIATELY telephone 000 and request the attendance of the NSW Fire Brigade as the principle emergency combat agency. Where injury to employees or facility users has occurred facility employees are to also request the attendance of the NSW Ambulance Service and the NSW Police Service.
(b) Facility employees are also required to IMMEDIATELY notify the Group Manager Commercial Business Units (who for the purposes of this plan will be the designated Emergency Response Manager), and the Safety Coordinator. Where
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 12
the Group Manager Commercial Business Units is not available the Waste Manager Waste Coordinator shall assume the role of Emergency Response Manager.
(c) The Emergency Response Manager (Group Manager Commercial Business Units, Waste Manager or Waste Coordinator) is to attend the site as a matter of urgency.
(d) Upon assessment of the situation the Emergency Response Manager is to notify by telephone other emergency combat and/or support agencies as deemed appropriate.
In addition to the immediate notification of any serious incident or event, a PMHC Injury and Incident Report Form is to be completed and forwarded to the Group Manager of Environmental Services, with a copy forwarded to the Safety Coordinator and Workers Compensation Officer. The Emergency Response Manager responsible for the management of the incident may notify the following Council staff or elected Officials of the incident, at the Manager’s discretion:
• General Manager • Divisional Director(s) • Community Relations Staff • Mayor • Elected Councillors
4.3.4 Communicating with neighbours and the local community Communication for the purpose of notification of an incident can be in the form of:
Website
Social media
Phone calls
SMS (Short Message Service)
Letterbox drops
Doorknocking Information to be provided to the community should include specific details that would minimise harm to the community. For example:
Instructions to close windows and doors (for incidents involving air pollutants).
Instructions to avoid contact with water in creeks affected by pollutant discharge. Consideration of location, geography and proximity to neighbours must be considered in terms of the type of pollution incident likely to occur. Consideration must be given to notifying any sensitive premises in close proximity such as schools, pre-schools, nursing homes and hospitals.
4.3.5 Media Notification Port Macquarie-Hastings Council recognises that it is essential to present accurate information to the news media concerning any serious emergency situation involving waste facilities. In the event of a serious emergency involving a facility, the Group Manager Commercial Business Units, relevant Director, General Manager or his/her nominee are the only authorised individuals who may speak with the media on behalf of the Council. Any requests for information concerning the facility, employees, or facility users will be referred to the Group Manager Commercial Business Units or his/her nominee.
4.3.6 Procedures Appendix 2 of this PIRMP contains relevant Standard Operating Procedures (SOP’s) that are included in the PMHC Solid Waste Management, Waste Policies, SOPs and Safe Work Method Statements, 2017. The above document containing all PMHC SOPs is kept at all
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 13
Council waste facilities. Under no circumstances are the SOP’s to be varied or altered unless there is a risk to personal or public safety.
4.3.7 Post Emergency Activities This section of the PIRMP identifies those activities necessary to support staff during and following an emergency situation and those activities necessary to restore operations at the Waste Facility or transfer station.
4.3.8 Recovery Operations The recovery of facility operations and services will depend on the extent of damage to the facility. The Group Manager Commercial Business Units will need to prioritize activities that can be accomplished with available staff and resources. Immediately following the emergency phase of an incident, the Group Manager Commercial Business Units and Waste Coordinator will develop an Operational Recovery Plan.
4.3.9 Incident Investigation The pollution incident must be investigated as soon as possible following its occurrence. The investigation is designed to determine why the incident occurred and what precautions can be taken to prevent a recurrence. The Group Manager Commercial Business Units is responsible for ensuring that an incident investigation is conducted following all emergency situations that occur at the facility. The Safety Coordinator will be included in the investigation process.
4.3.10 Small Incidents For small incidents, the Waste Coordinator will normally conduct the investigation.
4.3.11 Medium and Large Incidents For medium to large incidents, especially those involving injury, loss of life or property damage statutory authorities and emergency response agencies will be involved in conducting the investigation. These incidents will likely trigger the PIRMP. The Waste Coordinator and the Group Manager Commercial Business Units will assist the authorities as needed.
4.3.12 Documentation Documentation of emergency activities is of critical importance following the incident. All records and forms used during the incident to document activities must be retained for future reference. Following an emergency situation, the Waste Coordinator will have the responsibility for collecting all records and forms used during the incident. These will be used for several purposes, such as incident investigation, insurance claims, and potential legal actions. The Waste Coordinator and/or Waste Manager must prepare a report documenting activities that took place during the emergency situation. This report and all related documentation will be submitted to the Group Manager Commercial Business Units for review and necessary follow-up actions. The Group Manager Commercial Business Units shall report the findings and necessary corrective actions to the Director Corporate Performance.
4.3.13 Incident Damage Assessment Following an incident, an assessment of damage that has occurred to the facility and equipment must be conducted. The major goal of this assessment will be to determine the extent of damage to facilities, safety hazards resulting from the incident, and repairs that must be initiated to minimise further damage and restore the facility for operational use.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 14
The Waste Manager will have the primary responsibility for conducting the damage assessment following an incident. Assistance will be obtained as needed from facility employee and outside organizations, such as structural engineering firms.
4.3.14 Incident Debriefing The purpose of incident debriefing is to inform employees about any hazards that may still remain on the facility property following the incident and to identify unsafe conditions that may still exist. Some staff may be impacted by the events surrounding the incident, especially those involving injuries or loss of life. The Group Manager Commercial Business Units shall make arrangements for counselling services as needed following an emergency situation.
4.4 Incident Critique
The critique of the incident is a review of what actions took place during the incident, both good and bad. A critique is not designed to place blame, but rather to allow for the flow of ideas and recommendations to improve the emergency response plan and the facility policies and procedures. The incident critique should take place within a month of the incident, and involve staff who were involved on site and during incident response, as well as the Waste Coordinator, Waste Manager and Group Manager Commercial Business Units.
4.5 Review of the Pollution Incident Response Management Plan
After an incident the PIRMP will need to be reviewed to ensure that it is relevant and operated as required during the incident. One (1) month after the incident a test of the plan is required, to ensure that the updated plan is effective.
4.6 Staff training
To ensure that the PIRMP is properly followed during facility incidents, training will be provided to employees. The objectives of the training program are as follows:
To ensure that employees are knowledgeable about their roles and responsibilities outlined in the PIRMP.
To ensure that employees are knowledgeable of procedures to effect a safe response to facility pollution incidents.
To ensure that employees are knowledgeable of the evacuation procedures to effect a safe and expedient evacuation of the appropriate areas of the facility impacted by a serious pollution incident.
To ensure that employees are knowledgeable of new legislation related to how pollution incidents are reported and managed.
Facility employees will receive training in the PIRMP appropriate to the level of their expected involvement. The following is the general training program.
4.6.1 Training Frequency Employees will receive training during initial employment orientation and refresher training at least annually. When employees change areas in which they work or responsibilities for the work they undertake, they will receive appropriate training in their responsibilities and actions required by the plan for their new work area/new responsibilities. Additional training will also be provided to employees whenever the plan is changed.
4.6.2 Training Level All employees will receive training in the procedures of the plan. Training shall cover:
Notification procedures
Evacuation procedures
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 15
Incident discovery and management (standard operating procedures)
Simulated incident exercises
Fire suppression equipment use
First aid
The identification and storage of hazardous materials/wastes Training may be in the form of toolbox talks, formal staff training and practical simulations of emergency situations. Training records will be managed by the Waste Coordinator and the Human Resources section.
4.6.3 Supervisor Training All supervisors will receive additional training, beyond that received by employees, dealing with actions that are necessary to provide for the safety of employees and facility users, environmental reporting and notification of relevant authorities, and the protection of facility assets.
4.6.4 Training Competencies Details of the training competencies achieved by employees who are relevant to this plan will be kept on record.
5 TESTING PLANS
The following section outlines testing of PIRMPs.
5.1 Plan Review
This PIRMP will be reviewed at least annually by the Group Manager Commercial Business Units in conjunction with relevant employees. When revisions are made to the plan all waste staff will receive a updated PIRMP. Along with the changes, notice will be sent to all waste staff indicating the page, section and a description of the change.
5.2 Testing
To ensure that the plan will meet current conditions and that all involved individuals will respond properly, the plan will be tested on an annual basis, at each of the specified sites. Testing can be in the form of a desktop simulation or a practical exercise or drill. Testing must cover all components of the plan, including the effectiveness of training. Contractors on site may also be involved in the test. The testing will include at least the following;
1. Notification of procedures 2. Evacuation and accountability of personnel 3. Response time of emergency response personnel to emergency situation 4. Adherence to plan procedures 5. All drills and exercises of the plan will be documented, indicating the site, the manner
in which the testing was carried out, the date and results of the exercise and any problems that were encountered, along with recommendations for plan modifications.
6. Names of the staff members that carried out the testing are to be recorded 7. Updates to the plan must be documented and distributed to all staff.
The plan must also be tested within one (1) month of any pollution incident, to ensure that the information included in the plan is accurate and up to date, and that the plan can be implemented in an effective manner.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 16
Each time a test is carried out a PIRMP Exercise Evaluation Form will be completed by the staff observing the test. This will be provided to all relevant staff including the Group Manager Commercial Business Units - refer to Appendix 1, and maintain copies for review.
6 IMPLEMENTING PLANS
If a pollution incident occurs at any Waste Facility so that material harm to the environment is caused or threatened, Council staff attending the incident must immediately implement any pollution incident management response plan that was developed to meet the requirements of the POEO Act. PIRMP’s for each facility are attached.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 17
THE CAIRNCROSS WASTE MANAGEMENT FACILITY
Pollution Incident Response Management Plan
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 18
THE CAIRNCROSS WASTE MANAGEMENT FACILITY
The site address is 351 Telegraph Point Road, Pembrooke. The site is bounded by Cairncross State Forest to the north, east and south; National Park reserve to the southeast; and by Pembroke Road to the west. The location of the facility is shown on Figure 1 (section 7.1). The Waste Management Facility was constructed to replace the existing Port Macquarie landfill which was closed in 2001. The facility includes a weighbridge, office and staff amenities. A waste transfer station is also present for local domestic use. This removes the need for domestic vehicles to travel onto the landfill area. Stockpile and storage facilities are also provided for materials not able to be land filled for which processing and reuse alternatives are available. Other facilities include waste processing and recovery area, vehicular storage facility, water supply dam and site infrastructure. An Organic Resource Recovery Facility (ORRF) is located at Cairncross Waste Management Facility, and accepts domestic and commercial organic waste material. This material is mulched and incorporated with bio-solids from Councils sewage treatment plants, which are also received at this site. Composting of these materials is undertaken at the site. A Materials Recovery Facility (MRF) is also present on the site. The MRF processes all the recyclable material collected as part of the domestic collection service, as well as commercially collected recyclables. The Material Recovery Facility is separately licenced to Cairncross and maintains its own pollution incident response management plan. The general plan of the site and the major functional areas of the site are shown in Figure 2 as well as future stages of landfill development. General waste from both domestic and commercial collection services are transported directly to the Cairncross Waste Management Facility. All recyclable and organic wastes collected as part of the domestic kerbside collection service are also transported to the Cairncross Waste Management Facility where resource recovery, processing, reuse and land filling activities are undertaken. The Facility also receives all commercial and industrial waste, such as building and demolition waste and waste hauled in bulk from transfer stations located at Port Macquarie, Wauchope, Kew and Comboyne. The Cairncross facility services a population of approximately 78,000. The landfill is being developed in cells over a number of years. Each cell is progressively excavated to a predetermined level and lined with compacted clay. Excavated material is stockpiled and used to meet daily cover requirements over the deposited waste. The landfill will be filled to final contour levels in sections and progressively capped with stockpiled material and the surface rehabilitated. Landfill current drainage systems are shown in Figure 3, ORRF Leachate Management Plan diagram in Figure 4, site monitoring points in Figure 5, on the following pages.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 19
6. Maps
Figure 1: Location of Facility
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 20
Figure 2: Layout of Waste Management Facility and landfill staging plan
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 21
Figure 3: Current drainage diagram Cairncross Landfill
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 22
Figure 4: ORRF Leachate Management design
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 23
Figure 5: Cairncross Landfill - Bore and Surface Water Monitoring Point Locations
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 24
Figure 6: Cairncross Transfer Area - Hazardous Waste Locations
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 25
Table 3: Contacts for Contractors on site
COUNCIL WASTE STAFF - Cairncross
Position Name Mobile Contact Contact
Group Manager Commercial Business Units
Ashley Grummitt 0403 361 610 6581 8043
Waste Manager Michael Magalhaes 0438 667 492 6581 8125
Waste Services Coordinator Wayne Lenard 0407 417 414 6581 8076
Relieving Waste Services Coordinator/ Team Leader Cairncross
Andrew Collins 0419 419 690 -
Weighbridge Attendants Cairncross
Glenn Twaddell Paul Cini
- 6585 0738
COUNCIL HUMAN RESOURCES STAFF
Safety Coordinator Graham Chandler 0400 818 867 6581 8601
Employee Relations Officer Brenna Southwell - 6581 8606
CONTRACTORS ON SITE – Cairncross
Position Name Mobile Contact Office Contact
JR Richards MRF Manager Martin Holmes 0428 661 355 6581 3062
Remondis Manager Peter Mare 0425 226 466 6585 0899
Remondis Operations Supervisor
Jason Magill 0408 866 045 6585 0899
East Coast Revalvers Jim Rutherford 0467 728 025
Ledonne Kevin Brown 0427 773 091
6.1 Communicating with neighbours and the local community
Cairncross is a fairly isolated site with the closest neighbours being rural properties on Pembrooke Road (1173 - 970m) and Telegraph Point Road (447 - 1500m), and the closest town the small community of Telegraph Point, over 10km north on the Telegraph Point Road. Telegraph Point Public School is the closest school and the closest hospital, fire station and ambulance service are located at Wauchope. See Figure 1 for locality. In the event of an incident the decision to notify neighbours and local communities will be made by the Group Manager Commercial Business Units, with advice from local emergency authorities.
6.2 Minimising harm to persons on the premises
Specific SOPs have been developed for Facility Evacuation for each waste site. These have been attached as Appendix 2.
6.3 Site details
A list of potential hazards has been included in a table in the following pages for the Cairncross Waste Management Facility.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 26
Risk Rating Key
This matrix has been used to assign risk ratings in Table 4 below, and in the following sections related to Hazards at each facility.
Table 4
IMPACT
Legend
Catastrophic 12 18 21 24 25
CRITICAL
Major 10 14 19 22 23
HIGH
Moderate 6 9 15 17 20
MEDIUM
Minor 3 5 8 13 16
Insignificant 1 2 4 7 11 LOW
Rare Unlikely Possible Likely Almost
Certain
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 27
6.4 Description and likelihood of hazards
Possible pollution incident events associated with the operation of the Cairncross Waste Management Facility are included in Table 5 below. Table 5
Risk Description Risk Response Post Response Severity /
Likelihood
Residual Risk Rating
Relevant SOPs
Bushfire Injury to staff or visitors to the site Early warning and evacuation of site if necessary Rare/minor LOW SOP 11,12,17
Risk of fire spread to within the Waste Facility site
Fire prevention and sufficient fire fighting capacity Rare/major HIGH SOP11-15
Fire in stockpiles/ loads/ Transfer bins
Injury to staff or visitors to the site
Early warning and evacuation of site if necessary
Restriction of visitors to affected area
Care taken managing fire, following SOPs
Rare/minor LOW SOP11,17,23
Damage to the environment through air pollution from incineration of treated/composite timber, Drummuster drums, transfer bins, hazardous materials area etc.
Fire prevention and sufficient fire fighting capacity
Checking of loads
Rare/moderate MEDIUM SOP9,11-15,24,32
Risk of fire spreading to other parts of the Waste Facility site
Fire prevention and sufficient fire fighting capacity
Adequate procedures for contractors on site
Rare/minor LOW SOP11-15
Fire in transfer station/ building
Injury to staff or visitors to the site Early warning and evacuation of site if necessary Rare/major HIGH SOP11,17,23
Air pollution from incineration of hazardous materials, waste, tyres etc.
Fire prevention and sufficient fire fighting capacity
Checking of loads
Rare/moderate MEDIUM SOP9,11-15,24
Pollution of surface water, groundwater through ash or airborne contaminants
Site inspection and auditing
Surface water controls
Monitoring program
Sediment barriers where necessary
Rare/moderate MEDIUM SOP9,11-15,39
Contamination from stockpile areas Surface water controls
Monitoring program
Regular environmental testing
Rare/minor LOW SOP32,38
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 28
Pollution of groundwater
Discharges of contaminants Paint, oil, chemicals etc.
Site inspection and auditing
Surface water controls
Monitoring program
Regular environmental testing
Bunding
Rare/moderate MEDIUM SOP18,37-39,45
Leachate leak Leachate barrier /collection system management
Monitoring program
Site inspection and auditing
Rare/moderate MEDIUM SOP27,29
Contamination from stockpile areas Correct stockpile management
Site inspection and auditing
Rare/minor LOW SOP32,39
Pollution of surfacewater
Discharges of contaminants Site inspection and auditing
Surface water controls
Monitoring program
Regular environmental testing
Bunding
Rare/moderate MEDIUM SOP18,37-39,45
Leachate leak Leachate barrier /collection system management
Monitoring program
Site inspection and auditing
Rare/moderate MEDIUM SOP27,29
Contamination from stockpile areas Correct stockpile management
Site inspection and auditing
Rare/minor LOW SOP32,39
Explosion of gas bottles or storage tanks
Damage to the environment through air pollution
Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP20-22
Spread of fire to other parts of the facility Fire prevention and adequate fire fighting capacity Rare/major HIGH SOP 11-15
Spread of poisonous or odorous gases
Injury to staff or visitors to the site Early warning and evacuation of site if necessary
Restriction of visitors to affected area
Rare/moderate MEDIUM SOP11,17,23
Damage to the environment Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP20,21
Spill of chemicals / dangerous materials
Injury to staff or visitors to the site Early warning and evacuation of site if necessary
Restriction of visitors to affected area
Rare/major HIGH SOP17,22,23
Damage to the environment Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP9
Oil spill Damage to the environment Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP4,9,22
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 29
6.5 Pre-emptive actions to be taken
Reference to the pre-emptive actions and relevant SOPs for each nominated hazard are included in Table 5.
6.5.1 Site Checks As a part of the Cairncross Waste Management Facility Operational Environmental Management Plan (OEMP) checks are carried out on site on a regular basis, in order to best manage the site and prevent pollution incidents. Contractors on site are also a part of the process. A copy of the site checks is available in Waste Services SOP 39.
6.5.2 Environmental Monitoring Environmental monitoring is carried out quarterly on the site, continuing the monitoring required by the Environmental Protection Licence. A copy of the environmental testing methodology is included in the Waste Services SOP 38.
6.5.3 Fire Protection Fire fighting equipment installed and available at the facility includes the following:
Portable fire extinguishers within site buildings
Fire hydrants
Portable extinguishers attached to all site plant and equipment for immediate use in the event of a fire (eg. Landfill Compactor and Excavator).
In addition:
Clearly visible signs will be installed on site to ensure that all site personnel and the fire brigade are aware of the locations of this equipment.
Fire fighting equipment and facilities will be visually inspected on a weekly basis and tested on a quarterly basis.
All waste management facility staff will receive basic training in the operation of available fire fighting equipment and fire fighting methods.
Officers of the NSW Fire Brigades and the NSW Rural Fire Service will be invited to inspect the facility on an annual basis to ensure familiarity with site and its fire fighting capabilities.
Given the location of the Facility and the possibility of a bushfire impacting upon the facility the Bushfire and Fuel Management Plan (2001) which has been prepared for the Facility will be implemented.
6.5.4 Communication System The weighbridge has a phone line and a computer with internet access. A list of emergency phone numbers will be clearly displayed at the weighbridge. Other staff on site have mobile phones & two-way system.
6.5.5 Security Because of the hazards associated with chemicals and dangerous goods stored within the Waste Management Facility, and contractors materials on site, access to the facility is controlled and restricted to those persons having a legitimate reason to be on site. Access to the facility by unauthorised persons and unauthorised activities occurring on the site will be controlled by security fencing with security locks on all gates, doors and storage containers. Security cameras have been installed at the weighbridge overseeing the weighbridge and inside the weighbridge office. Security Cameras are also installed overseeing the stockpile area.
6.5.6 Signs and Labels Signage indicating opening times, access and restricted access requirements are on the exterior of the facility. Signage is in the transfer station indicating the location of fire suppression equipment, first aid kit, eye wash and shower.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 30
6.5.7 Spill Kits It is imperative that the Waste Management Facility be able to handle any small chemical spill and that all chemical spills receive immediate attention. Spill kits have been provided and located in high-risk areas. These are easily identifiable and accessible. Contents include stocks of absorbent material (eg. pillows, soil or sawdust “kitty litter”), protective clothing; and secure skips bins for these materials once they have been used and contaminated.
6.6 Inventory of pollutants on site
The Cairncross Waste Management Facility can store up to a total of 5000 kilograms of hazardous materials on site in the Hazardous Materials Storage Area (HMSA) without requiring any additional approval by the EPA. A summary of the materials generally kept on site is included in Table 6 below: Table 6
Pollutant Location Quantity Storage Comment
Transfer Station – public drop off point Batteries (nickel cad/nickel hydride/other)
Transfer station
Low HMSA Small amounts only from residential dropoffs (under 20 litres allowed per drop off). The transfer station is short term storage only.
Fire extinguishers (halon/other) Transfer station
Low HMSA
Flammable liquids Transfer station
Low HMSA
Gas cylinders (propane/other) Transfer station
Low HMSA
General household cleaners Transfer station
Low HMSA
Hydrocarbons and fuels Transfer station
Low HMSA
Intractable chemicals Transfer station
Low HMSA
Paints and varnishes (water/solvent/metal based)
Transfer station
Low HMSA
PCB materials Transfer station
Low HMSA
Pesticides (liquid/solid – including organochlorine)
Transfer station
Low HMSA
Poisons Transfer station
Low HMSA
Unknowns (liquid/solid) Transfer station
Low HMSA
General solid waste Transfer station
Up to 10T Bins Transfer bins, recycling bins
PMHC Staff Small amounts of fuel and oil (<20l) Transfer
station Low Site shed All hazardous
materials are accompanied by MSDS sheets and SOPs.
Small amounts of herbicides Transfer station
Low Site Shed
Landfill Leachate Leachate
tanks and dams
Up to Tanks: 76,000L Dams: 200,000L
Dams are open and tanks are enclosed
Dams infiltrate back into landfill. Tanks are closed connections to leachate lines under the landfill.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 31
Sediment-laden water Sediment basins/dams
Up to South: 5,050,000L West: 500,000L North: 200,000L Firefighting: 3,000,000L
Open dams
Stormwater only
General solid waste Landfill Up to 100,000 T p.a.
Landfill Landfilled waste
Immobilised waste Landfill Up to 100,000T p.a.
Landfill Rarely receive this waste
Asbestos Landfill Up to 100,000T p.a.
Landfill Asbestos hole is separate location from active face and moves often
Remondis ORRF
Caltex Vortex Diesel At rear of ORRF
2500 litres Above ground storage tank
Fire extinguisher in proximity
Caltex 68 Hydraulic Oil Containment tanks inside the workshop
205 litres Workshop Fire extinguisher, spill kit and first aid kit in workshop. All hazardous materials MSDS stored in site office
Caltex Delo 400 Engine Oil 40 litres
Caltex Rando Transmission Oil 20 litres
Caltex Thuban Gear Oil
20 litres
Caltex Regal R & O Turbine Oil 20 litres
Chemtech Truck degreaser
20 litres
20ltrs Chemtech Truck wash
20 litres
20ltrs Glysophate 360 Harbicide
20 litres
20ltrs Westrac ECL Engine Coolant 20 litres
Leachate Leachate dams and tanks
3,100,000L Dams are open and tanks are enclosed
Located behind (north) the ORRF
Sediment-laden water Firefighting dam
Up to 560,000L
Open Dam
Stormwater only
General solid waste Whole site Up to 50,000T p.a.
Whole site
Mulch, food waste, compost, biosolids, residual
JR Richards MRF Alpha sp 220 MRF 205 litre Workshop Fire
extinguisher, spill kit and first aid kit in workshop.
Boss tip dip gel MRF 500 gm Workshop Beltgrip MRF 500gm Workshop Brake fluid MRF 4 litres Workshop Cleaners, insect sprays MRF spray Workshop Cyndan truck wash MRF 20 litre Workshop Delo multigrade MRF 20 litre Workshop
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 32
Delo synthetic gear lubricant MRF 20 litre Workshop All hazardous materials MSDS stored in site office
Diesel MRF 410 litre Workshop Dot 4 MRF 4 litre Workshop INOX Mx3 MRF 2 litre Workshop Killrust MRF 500 ml Workshop LPG automotive MRF 2 litre Workshop Lanox Lx4 MRF 4 litre Workshop LMX grease MRF 4 kg Workshop Loctite nickel anti seize MRF 300 gm Workshop Meropa 220 MRF 205 litre Workshop Mineral turpentine MRF 4 litre Workshop Glyphosate MRF 1 litre Workshop Nilos solution MRF 1 litre Workshop Paints MRF <20 litres Workshop Prime remover MRF 20 litres Workshop Plus rust converter MRF 4 litres Workshop Spill sorb MRF 140 litres Workshop Thuban GL5 EP SAE MRF 20 litres Workshop TFC 410 MRF 20 litres Workshop Unleaded petrol MRF 20 litres Workshop Wattyl universal thinner MRF 4 litres Workshop Sediment-laden water Firefighting
dams Up to 144,000L
West of MRF
Stormwater only
General solid waste Whole site Up to 3500T
Whole site
Recyclables and residual waste
6.7 Safety equipment
Safety equipment Appropriate personal protection equipment (PPE) for chemical and hazardous material protection such as hard hats, safety glasses and/or other eye protection, overalls, gloves, chemical splash suits, masks, boots, etc. are kept in the Council site shed.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 33
THE PORT MACQUARIE WASTE MANAGEMENT FACILITY
(Kingfisher Road)
Pollution Incident Response Management Plan
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 34
7 THE PORT MACQUARIE WASTE MANAGEMENT FACILITY
The Port Macquarie Waste Management Facility is located on Lot 11, DP 875998, at the end of Kingfisher Road Port Macquarie. The site is zoned the Port Macquarie Hastings Council Local Environment Plan 2011 (SP2) Special Purpose (Infrastructure). The overall waste management centre site is roughly square, approximately 16.5 hectares in area and is located approximately 3.5km south west of the Port Macquarie CBD. Council has used the Port Macquarie Waste Management Facility for waste disposal and management purposes for in excess of 35 years with the centre being originally established by Port Macquarie Municipal Council as a solid waste landfill to serve the needs of the Port Macquarie community. The landfill was closed and capped by 2001 with the opening of the Cairncross Landfill and Waste Management Facility, and the site established as a transfer station, carrying out a variety of waste recovery and recycling activities including:
Recovery of recyclable material prior to delivery to the Cairncross MRF
Processing of green wastes prior to delivery to the Cairncross ORRF
Processing of inert building wastes
Waste oil recovery
Aqueous Waste (grease and oils) recovery
Hazardous materials storage area (set up as an EPA Community Recycling Centre since 2015)
Collection and storage of ewaste for recycling
Collection and storage of mattresses for recycling
Collection and storage of tyres for recycling It is the operation of the Waste Transfer Station that forms the basis of this PRIMP. Council staff manage the transfer station and the weighbridge. Contractor Crowe Oil recycling leases a site to the west of the transfer station. The old MRF buildings to the north east are currently unoccupied. Council carries out environmental testing around the closed landfill site as required by the old environmental protection licence. Gas bores were installed in early 2015 so that landfill gas testing could be carried out to determine the current gas levels due to the development of the surrounding land. These bores are being tested monthly. Results show consistently low levels of methane. Due to changes in the Waste Regulation Council in 2015 Council now has an Environmental Protection Licence (EPL 20698) for the transfer station site and stockpile areas, which will be modified in consultation with the EPA as the site develops.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 35
7.1 Maps
Figure 1: Location of Facility
Figure 2: Layout of Waste Management Facility
Location of the Port Macquarie Waste Management
Centre
Inactive Landfill Mass Transfer Station
Green Waste Area
Metals Stockpile Area
Old MRF, currently
unoccupied
Aqueous Waste
Facility
Oil Recovery Area (Crowe
Oil recycling)
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 36
Figure 3 Layout of Waste Transfer Station
Recyclable and Hazardous Materials storage areas
Waste Transfer Station office and amenities area
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 37
Figure 4: Old Port Macquarie landfill stormwater drainage diagram
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 38
Figure 5: Port Macquarie Waste Management Facility stockpile area leachate management design
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 39
7.2 Contacts and communication
Table 7
COUNCIL WASTE STAFF - Cairncross
Position Name Mobile Contact Contact
Group Manager Commercial Business Units
Ashley Grummitt 0403 361 610 6581 8043
Waste Manager Michael Magalhaes 0438 667 492 6581 8125
Waste Services Coordinator
Wayne Lenard 0407 417 414 6581 8076
Relieving Waste Services Coordinator/ Team Leader Cairncross
Andrew Collins 0419 419 690 -
Weighbridge Attendants PMWMF
Craig Smith Paul Dymock
- 6585 0738
COUNCIL HUMAN RESOURCES STAFF
Safety Coordinator Graham Chandler 0400 818 867 6581 8601
Employee Relations Officer
Brenna Southwell - 6581 8606
CONTRACTORS ON SITE – Port Macquarie
Position Name Mobile Contact Office Contact
B&M Crowe Brett Crowe 0417 299 823 6584 6040
7.3 Communicating with neighbours and the local community
The Port Macquarie Waste Management Facility is located in the middle of Port Macquarie. The nearest residential neighbours are located on Kingfisher Road, and the Industrial area (Geebung Close) borders the site to the North East. St Columba Anglican College is located to the South West of the old landfill site, and Charles Sturt University to the South east. Lake Innes Village shopping centre is also located nearby. In the event of an incident the decision to notify neighbours and local communities will be made by the Group Manager Commercial Business Units, with advice from local emergency authorities.
7.4 Minimising harm to persons on the premises
Specific SOPs have been developed for Facility Evacuation for each waste site. These have been attached as Appendix 2.
7.5 Site Details
A list of potential hazards has been included in a Table 8 in the following pages for the Port Macquarie Waste Management Facility. Refer to the risk management matrix on page 18 if necessary.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 40
7.6 Description and likelihood of hazards
Possible pollution incident events associated with the operation of the Port Macquarie Waste Management Facility are included in Table 8 below:
Table 8
Risk Description Risk Response Post Response Severity /
Likelihood
Residual Risk Rating
Relevant SOPs
Bushfire Injury to staff or visitors to the site Early warning and evacuation of site if necessary Rare/minor LOW SOP 11,12,17
Risk of fire spread to within the Waste Facility site
Fire prevention and sufficient fire fighting capacity Rare/major HIGH SOP11-15
Fire in stockpiles/ loads/ Transfer bins
Injury to staff or visitors to the site
Early warning and evacuation of site if necessary
Restriction of visitors to affected area
Care taken managing fire, following SOPs
Rare/minor LOW SOP11,17,23
Damage to the environment through air pollution from incineration of treated/composite timber, drummuster drums, transfer bins, hazardous materials area etc.
Fire prevention and sufficient fire fighting capacity
Checking of loads
Rare/moderate MEDIUM SOP9,11-15,24,32
Risk of fire spreading to other parts of the Waste Facility site
Fire prevention and sufficient fire fighting capacity
Adequate procedures for contractors on site
Rare/minor LOW SOP11-15
Fire in transfer station/ building
Injury to staff or visitors to the site Early warning and evacuation of site if necessary Rare/major HIGH SOP11,17,23
Air pollution from incineration of hazardous materials, waste, tyres etc.
Fire prevention and sufficient fire fighting capacity
Checking of loads
Rare/moderate MEDIUM SOP9,11-15,24
Pollution of surface water, groundwater through ash or airborne contaminants
Site inspection and auditing
Surface water controls
Monitoring program
Sediment barriers where necessary
Rare/moderate MEDIUM SOP9,11-15,39
Contamination from stockpile areas
Surface water controls
Monitoring program
Regular environmental testing
Rare/minor LOW SOP32,38
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 41
Pollution of groundwater
Discharges of contaminants Paint, oil, chemicals etc.
Site inspection and auditing
Surface water controls
Monitoring program
Regular environmental testing
Bunding
Rare/moderate MEDIUM SOP18,37-39,45
Leachate leak Leachate barrier /collection system management
Monitoring program
Site inspection and auditing
Rare/moderate MEDIUM SOP27,29
Contamination from stockpile areas
Correct stockpile management
Site inspection and auditing
Rare/minor LOW SOP32,38
Pollution of surfacewater
Discharges of contaminants Site inspection and auditing
Surface water controls
Monitoring program
Regular environmental testing
Bunding
Rare/moderate MEDIUM SOP18,37-39,45
Leachate leak Leachate barrier /collection system management
Monitoring program
Site inspection and auditing
Rare/moderate MEDIUM SOP27,29
Contamination from stockpile areas
Correct stockpile management
Site inspection and auditing
Rare/minor LOW SOP32,38
Explosion of gas bottles or storage tanks
Damage to the environment through air pollution
Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP20-22
Spread of fire to other parts of the facility Fire prevention and adequate fire fighting capacity Rare/major HIGH SOP 11-15
Spread of poisonous or odorous gases
Injury to staff or visitors to the site
Early warning and evacuation of site if necessary
Restriction of visitors to affected area
Rare/moderate MEDIUM SOP11,17,23
Damage to the environment
Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP20,21
Spill of chemicals / dangerous materials
Injury to staff or visitors to the site Early warning and evacuation of site if necessary
Restriction of visitors to affected area
Rare/major HIGH SOP17,22,23
Damage to the environment Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP9
Oil spill Damage to the environment Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP4,9,22
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 42
7.7 Pre-emptive actions to be taken
7.7.1 Site Checks As a part of the Port Macquarie Waste Management Facility Operational Environmental Management Plan (OEMP) checks are carried out on site on a regular basis, in order to best manage the site and prevent pollution incidents. Contractors on site are also a part of the process. A copy of the site checks is available in Waste Services SOP 39.
7.7.2 Environmental Monitoring Environmental monitoring is carried out as required by the new licence, and also continuing the monitoring required by the original landfill EPL, which was surrendered. A copy of the environmental testing methodology is included in the Waste Services SOP 38.
7.7.3 Fire Protection The fire protection systems on site include fire extinguishers and fire hose reels. All equipment has been installed and are serviced and maintained in accordance with the relevant standards. The location of all fire protection equipment is clearly nominated/labelled so that employees faced with an emergency and under pressure, can confidently locate and select the appropriate type of equipment.
7.7.4 Communication System The site office has a phone line and a computer with internet access. A list of emergency phone numbers will be clearly displayed at a location within the facility that can be seen by both staff and members of the public.
7.7.5 Security Because of the hazards associated with chemicals and dangerous goods stored within the Transfer Station, and contractors materials on site, access to the facility is controlled and restricted to those persons having a legitimate reason to be on site. Access to the facility by unauthorised persons and unauthorised activities occurring on the site will be controlled by security fencing with security locks on all gates, doors and storage containers. Only facility staff shall be able to enter the chemical/hazardous substance storage area. Signs will be posted in sufficient numbers to be seen from any of the approaches to the storage area with a clear message. Security cameras have been installed in the transfer station area overseeing the site office and drop off points.
7.7.6 Signs and Labels All hazardous waste storage areas are clearly and individually labelled to indicate type of materials are stored in each area. Labels will be in large print and plain English. Signage indicating opening times, access and restricted access requirements has been placed on the exterior of the facility. A list of emergency phone numbers is clearly displayed at a location within the site office. Suitable signage indicating the location of fire suppression equipment, first aid kit, eye wash and shower is provided.
7.7.7 Spill Kits It is imperative that the Waste Transfer Station be able to handle any small chemical spill and that all chemical spills receive immediate attention. Spill kits have been provided and
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 43
located in high-risk areas and are easily identifiable and accessible. Contents include stocks of absorbent material, (eg pillows, soil or sawdust “kitty litter”); protective clothing; and secure skips for these materials once they have been used and contaminated.
7.8 Inventory of pollutants on site
The Port Macquarie-Hastings Council Waste Management Facility can store up to 5000 kilos of hazardous materials on site without requiring any additional approval by the EPA (although the site is generally cleared out every 2 weeks). The Port Macquarie Transfer Station is the drop off point for household hazardous materials for the community and has been approved for this purpose by the EPA, having been upgraded as a part of the Community Recycling Centre project in 2015. There is a designated area in the Transfer Station designed to store these materials, to await collection by the EPA’s Hazardous Waste Collection Contractor. A full list of the materials included in this collection contract is below though only a small range is generally stored in the transfer station at any one time.
7.8.1 Transfer Station Table 9 (below) shows a list of possible materials in storage on site in the transfer station hazardous materials compound, at any one time. Up to 5000 litres can be stored in the Transfer Station according to the Environmental Protection Licence. Table 9
Pollutant Location Quantity Storage Comment
Acids TS low HMSA These hazardous materials are stored in approved containers within a hazardous materials storage area. The site is serviced regularly by the EPA’s hazardous materials collection contractor (Cleanaway)
Alkalis TS low HMSA
Arsenic/arsenic based products
TS low HMSA
Batteries (nickel cad/nickel hydride/other)
TS low HMSA
Fire extinguishers (halon/other)
TS low HMSA
Flammable liquids TS low HMSA
Flares/ammunition TS low HMSA
Gas cylinders (propane/other) TS low HMSA
General household cleaners TS low HMSA
Heavy metal compounds TS low HMSA
Hydrocarbons and fuels TS low HMSA
Intractable chemicals TS low HMSA
Light globes (fluorescent/mixed)
TS low HMSA
Smoke detectors TS low HMSA
Organo peroxides TS low HMSA
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 44
Pollutant Location Quantity Storage Comment
Oxidising agents TS low HMSA
Paints and varnishes (water/solvent/metal based)
TS low HMSA
PCB materials TS low HMSA
Pesticides (liquid/solid – including organochlorine)
TS Up to 2000 l HMSA
Poisons TS low HMSA
Reactives TS low HMSA
Solvents (halogenated/non halogenated)
TS low HMSA
Toxics TS low HMSA
Pharmaceuticals TS low HMSA
Photographic chemicals TS low HMSA
Unknowns (liquid/solid) TS low HMSA
PMHC Staff
Small amounts of pesticides/herbicides
TS low Site office
B&M Crowe site
Motor oil Crowe site 40,000 litres Stored in licenced oil recovery facility Cooking oil Crowe site 15,000 litres
Coolant Crowe site 2000 litres
7.9 Safety equipment
8.4.4.1 Shower and eyewash station An emergency eyewash and shower equipment is located within 10 m of the hazardous material storage area in the transfer station. Eyewash and shower equipment is maintained and tested on a regular basis. 8.4.4.2 Safety equipment Appropriate personal protection equipment (PPE) for chemical and hazardous material protection such as hard hats, safety glasses and/or other eye protection, overalls, gloves, chemical splash suits, masks, boots, etc is kept in the site office in the Transfer Station and is accessible. PPE is replaced when necessary. On site staff must inform the Waste Coordinator when PPE supplies are running low so that replacement can be arranged.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 45
THE DUNBOGAN WASTE MANAGEMENT FACILITY
Pollution Incident Response Management Plan
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 46
8 THE DUNBOGAN WASTE MANAGEMENT FACILITY
The Dunbogan Waste Management Facility (WMF) is located on the southern fringes of the developed area of the village area of Dunbogan. Access to the site is via the ‘Tip’ Road which travels east from the main road of The Boulevard and connects the Dunbogan area with the township of Laurieton is located on the adjacent side of the Camden Haven River.
The site is roughly rectangular in shape and covers approximately 3.9 hectares. The site was closed in 2016 and capping was completed in 2018. The site is now unmanned, but environmental monitoring is carried out regularly including testing of surface water, ground water, leachate, and monitoring of landfill gas. The site is bounded by the Dunbogan Sewage Treatment Plant in the west and some developing urban areas to the north and north-west. Historically, the site was developed as a landfill in the early 1980s and provided waste disposal opportunities for local residents. The Dunbogan landfill predominately accepted wastes from non-putrescible sources. Putrescible wastes from both domestic and commercial collection services are transported directly to the Cairncross Waste Management Facility. The landfill was capped and closed in 2017, and replaced with a Waste Transfer Station at Kew which, in conjunction with the various waste collection services, provides for the management of solid wastes in the Camden Haven area. For this reason the site does not have a permanent office or staff but site checks and environmental monitoring is regularly carried out.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 47
8.1 Maps
Figure 1: Location of Facility
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 48
Figure 2: Dunbogan stormwater management plan
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 49
Figure 3: 250m buffer around Dunbogan Landfill
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 50
Table 10: Other Council contacts
COUNCIL WASTE STAFF
Position Name Mobile Contact Contact
Group Manager of Environmental Services
Ashley Grummitt 0403 361 610 6581 8043
Waste Manager Michael Magalhaes
0438 667 492 6581 8125
Waste Services Coordinator Wayne Lenard 0407 417 414 6581 8076
Relieving Waste Services Coordinator/ Team Leader Cairncross
Andrew Collins 0419 419 690 -
COUNCIL HUMAN RESOURCES STAFF
Safety Coordinator Graham Chandler 0400 818 867 6581 8601
Employee Relations Officer Brenna Southwell - 6581 8606
COUNCIL Dunbogan Sewerage Treatment Plant Staff
Position Name Mobile Contact Contact
Team Leader Michael Buckley 0438 599 918 NA
Water and Sewer Process Manager
Clayton Miechel 0427 270 486 6581 8047
8.2 Communicating with neighbours and the local community
The Dunbogan Waste Management Facility site is located in bushland off The Boulevard at Dunbogan. The nearest residential area is located directly north of the facility on the other side of Scarborough Way. Other residential areas area located to the west and continuing along The Boulevard to the North East. The nearest school is located in Laurieton, as are fire and ambulance services. In the event of an incident the decision to notify neighbours and local communities will be made by the Group Manager Commercial Business Units, with advice from local emergency authorities. When undertaking gas monitoring in buildings within 250m of the landfill (Figure 3), the operator will notify the Waste Manager immediately if readings exceed 500ppm. If readings exceed 12,500ppm the EPA will be notified immediately. The Waste Coordinator will liaise with Group Manager Commercial Business Units and the EPA to assess the requirement for evacuation.
8.3 Minimising harm to persons on the premises
Specific SOPs have been developed for Facility Evacuation for each waste site. These have been attached as Appendix 2.
8.4 Site Details
A list of potential hazards has been included in a Table 11 in the following pages for the Dunbogan Waste Management Facility (refer to the risk management matrix on page 18 if necessary).
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 51
8.5 Description and likelihood of hazards
Possible pollution incident events associated with the operation of the Dunbogan Waste Management Facility are shown below in Table 11: Table 11 Risk Description Risk Response Post Response
Severity / Likelihood
Residual Risk Rating
Relevant SOPs
Incident at adjacent Sewer Treatment Plant
Neighbouring site is a Dangerous goods site and any incident there could impact on the Dunbogan landfill
Early warning and evacuation of site if necessary Rare/ Moderate MEDIUM SOP 17
Bushfire Injury to staff or visitors to the site Early warning and evacuation of site if necessary Rare/minor LOW SOP 11,12,17
Risk of fire spread to within the Waste Facility site
Fire prevention and sufficient fire fighting capacity Rare/major HIGH SOP11-15
Pollution of groundwater
Leachate leak Leachate barrier /collection system management
Monitoring program
Site inspection and auditing
Rare/moderate MEDIUM SOP27,29
Pollution of surface water
Discharges of contaminants Site inspection and auditing
Surface water controls
Monitoring program
Regular environmental testing
Bunding
Rare/moderate MEDIUM SOP18,37-39,45
Leachate leak Leachate barrier /collection system management
Monitoring program
Site inspection and auditing
Rare/moderate MEDIUM SOP27,29
Spread of poisonous or odorous gases
Injury to staff or visitors to the site
Early warning and evacuation of site if necessary Rare/moderate MEDIUM SOP11,17,23
Accumulation of landfill gas on and off site Best practice management and environmental monitoring
Site inspection and auditing
Rare/moderate MEDIUM SOP11,17,23
Damage to the environment
Best practice management and environmental monitoring
Site inspection and auditing
Rare/moderate MEDIUM SOP20,21
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 52
8.6 Pre-emptive actions to be taken
The following section outlines pre-emptive actions to be taken in the event of an incident.
8.6.1 Site Checks As a part of the Dunbogan Waste Facility Operational Environmental Management Plan (OEMP) checks are carried out on site monthly, in order to best manage the site and prevent pollution incidents. A copy of the site checks is available in Waste Services SOP 39.
8.6.2 Environmental Monitoring Most environmental monitoring is carried out quarterly on the site as required by the Environmental Pollution Licence. Gas monitoring of buildings within 250m of the landfill is carried out monthly (this includes a number of dwellings to the north of the landfill). A copy of the environmental testing methodology is included in the Waste Services SOP 38.
8.6.3 Security To ensure security of the site, a 2.1m high wire mesh and barbed wire perimeter fence has been installed with lockable gates. This will ensure that unauthorised dumping of rubbish and trespassing on the site does not occur. The ongoing integrity of the perimeter fence is checked regularly.
8.6.4 Signs and Labels Signage indicating the site is closed and access restricted has been placed on the exterior of the facility.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 53
THE KEW WASTE TRANSFER STATION
Pollution Incident Response Management Plan
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 54
9 THE KEW WASTE MANAGEMENT FACILITY
The Kew Waste Transfer Station is located at 95 Herons Creek Road (Lot 14, DP 1103758), Kew. The site is zoned RU1 under the Port Macquarie-Hastings Council Local Environment Plan 2011. The Facility is approximately 1.4 hectares in area and is located approximately 1.5km north of Kew. Note the site does not hold an Environmental Protection Licence and is not required to have a Pollution Incident Response Management Plan (PIRMP). Council has completed this section to provide guidance to staff in the event of an incident. The Facility will provide waste management infrastructure to service the Camden Haven and southern PMHC LGA. The Facility services households disposing of car boot and trailer loads of various waste types. Small scale commercial enterprises may utilise the station on occasion, however the majority of commercial and bulk wastes will be transported directly to the Cairncross WMF. All waste deposited onsite will be removed offsite for reuse, resource recovery, processing or will be deposited into the landfill at the Cairncross WMF. Some of the activities that will be undertaken at the Facility are listed below.
Collection and storage of general waste into a push-pit and compactor bin system
Use of front-end loader in the push-pit and stockpile locations
Recovery of recyclable material prior to delivery to the Cairncross MRF
Processing of green wastes prior to delivery to the Cairncross ORRF
Processing of inert building wastes (concrete and brick)
Collection and storage of waste oil
Hazardous materials storage area (set up as an EPA Community Recycling Centre since 2019)
Collection and storage of e-waste for recycling
Collection and storage of mattresses for recycling
Collection and storage of tyres for recycling
Collection and storage of scrap metal for recycling
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 55
9.1 Maps
Figure 1: Location of Facility
Location of the Kew Waste
Transfer Station
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 56
Figure 2: Layout of Waste Management Facility
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 57
Figure 3: Layout of Stormwater drains
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 58
9.2 Contacts and communication
Table 12
COUNCIL WASTE STAFF – Port Macquarie
Position Name Mobile Contact Contact
Group Manager of Environmental Services
Ashley Grummitt 0403 361 610 6581 8043
Waste Manager Michael Magalhaes 0438 667 492 6581 8125
Waste Services Coordinator Wayne Lenard 0407 417 414 6581 8076
Relieving Waste Services Coordinator/ Team Leader Cairncross
Andrew Collins 0419 419 690 NA
Waste Attendants Kew Waste Transfer Station
Colin Applegate Steve Watson
- 6559 4983
COUNCIL HUMAN RESOURCES STAFF
Safety Coordinator Graham Chandler 0400 818 867 6581 8601
Employee Relations Advisor Brenna Southwell - 6581 8606
9.3 Communicating with neighbours and the local community
The Kew Waste Transfer Station is located 1.5km north of Kew. The nearest residential neighbours are located approximately 330m to the south, and the rest of surrounding land in close proximity is bushland. In the event of an incident the decision to notify neighbours and local communities will be made by the Group Manager Commercial Business Units, with advice from local emergency authorities.
9.4 Minimising harm to persons on the premises
Specific SOPs have been developed for Facility Evacuation for each waste site. These have been attached as Appendix 2.
9.5 Site Details
A list of potential hazards for the Kew Waste Transfer Station has been included in Table 13. Refer to the risk management matrix in Table 4.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 59
9.6 Description and likelihood of hazards
Possible pollution incident events associated with the operation of the Kew Waste Transfer Station are included in Table 13 below:
Table13 Risk Description Risk Response Post Response
Severity / Likelihood
Residual Risk Rating
Relevant SOPs
Bushfire Injury to staff or visitors to the site. Early warning and evacuation of site if necessary Rare/minor LOW SOP 11,12,17
Risk of fire spread to within the Waste Facility site.
Fire prevention and sufficient fire fighting capacity Unlikely/major HIGH SOP11-15
Fire in stockpiles/ loads
Injury to staff or visitors to the site.
Early warning and evacuation of site if necessary
Restriction of visitors to affected area
Care taken managing fire, following SOPs
Rare/minor LOW SOP11,17,23
Damage to the environment through air pollution from incineration of treated/ composite timber, hazardous materials area etc.
Fire prevention and sufficient fire fighting capacity
Checking of loads
Rare/moderate MEDIUM SOP9,11-15,24,32
Risk of fire spreading to other parts of the Waste Facility site.
Fire prevention and sufficient fire fighting capacity
Adequate procedures for contractors on site
Rare/minor LOW SOP11-15
Fire in transfer station/ building
Injury to staff or visitors to the site. Early warning and evacuation of site if necessary Rare/major HIGH SOP11,17,23
Air pollution from incineration of hazardous materials, waste, tyres etc.
Fire prevention and sufficient fire fighting capacity
Checking of loads
Rare/moderate MEDIUM SOP9,11-15,24
Pollution of surface water, groundwater through ash or airborne contaminants.
Site inspection and auditing
Surface water controls
Monitoring program
Sediment barriers where necessary
Rare/moderate MEDIUM SOP9,11-15,39
Contamination from stockpile areas.
Surface water controls
Monitoring program
Regular environmental testing
Rare/minor LOW SOP32,38
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 60
Pollution of groundwater
Discharges of contaminants Paint, oil, chemicals etc.
Site inspection and auditing
Surface water controls
Monitoring program
Bunding
Environmental testing when necessary
Rare/moderate MEDIUM SOP18,37-39,45
Contamination from stockpile areas
Correct stockpile management
Site inspection and auditing
Rare/minor LOW SOP32,38
Pollution of surface water
Discharges of contaminants Site inspection and auditing
Surface water controls
Monitoring program
Environmental testing when necessary
Bunding
Rare/moderate MEDIUM SOP18,37-39,45
Contamination from stockpile areas
Correct stockpile management
Site inspection and auditing
Rare/minor LOW SOP32,38
Explosion of gas bottles or storage tanks
Damage to the environment through air pollution
Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP20-22
Spread of fire to other parts of the facility Fire prevention and adequate fire fighting capacity Rare/major HIGH SOP 11-15
Spread of poisonous or odorous gases
Injury to staff or visitors to the site
Early warning and evacuation of site if necessary
Restriction of visitors to affected area
Rare/moderate MEDIUM SOP11,17,23
Damage to the environment
Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP20,21
Spill of chemicals / dangerous materials
Injury to staff or visitors to the site Early warning and evacuation of site if necessary
Restriction of visitors to affected area
Rare/major HIGH SOP17,22,23
Damage to the environment Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP9
Oil spill Damage to the environment Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP4,9,22
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 61
9.7 Pre-emptive actions to be taken
9.7.1 Site Checks As a part of the Kew Waste Transfer Station Operational Environmental Management Plan (OEMP) checks are carried out on site on a regular basis, in order to best manage the site and prevent pollution incidents. Contractors on site are also a part of the process. A copy of the site checks is available in Waste Services SOP 39.
9.7.2 Fire Protection The fire protection systems on site include fire extinguishers, fire hose reels and fire hydrants. All equipment has been installed and are serviced and maintained in accordance with the relevant standards. The location of all fire protection equipment is clearly nominated/labelled so that employees faced with an emergency and under pressure, can confidently locate and select the appropriate type of equipment. The site was designed with bushfire protection in mind given the close proximity to bushland and slope of the land. Defendable zones have been established around the building and a fire access track around the perimeter to allow for sufficient fire-fighting capacity.
9.7.3 Communication System The site office has a phone line and a computer with internet access. A list of emergency phone numbers is clearly displayed at the Facility so they can be seen by both staff and members of the public.
9.7.4 Security Because of the hazards associated with chemicals and dangerous goods stored within the Transfer Station, and contractors materials on site, access to the facility is controlled and restricted to those persons having a legitimate reason to be on site. Access to the facility by unauthorised persons and unauthorised activities occurring on the site is controlled by security fencing with security locks on all gates, doors and storage containers. Only facility staff shall be able to enter the chemical/hazardous substance storage containers. Signs will be posted in sufficient numbers to be seen from any of the approaches to the storage area with a clear message. Security cameras have been installed in the transfer station area overseeing the site office and drop off points. An alarm system is in place in the office to restrict access. This also has the ability to set off a siren for police, fire, and ambulance related emergencies.
9.7.5 Signs and Labels All hazardous waste storage areas are clearly and individually labelled to indicate which materials are stored in each area. Labels will be in large print and plain English. Signage indicating opening times, access and restricted access requirements has been placed on the exterior of the facility. A list of emergency phone numbers is clearly displayed at a location within the facility that can be seen by both staff and members of the public. Suitable signage indicating the location of fire suppression equipment, first aid kit, eye wash and shower is provided.
9.7.6 Spill Kits It is imperative that the Waste Transfer Station be able to handle any small chemical spill and that all chemical spills receive immediate attention. Spill kits have been provided and
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 62
located in high-risk areas and are easily identifiable and accessible. Contents include stocks of absorbent material, (e.g. pillows, soil or sawdust “kitty litter”); protective clothing; and secure skips for these materials once they have been used and contaminated.
9.8 Inventory of pollutants on site
The Kew Waste Transfer Station can store up to 5000 kilos of hazardous materials on site without requiring any additional approval by the EPA (although the site is generally cleared out every 2 weeks). The Kew Waste Transfer Station is the drop off point for household hazardous materials for the community and has been approved for this purpose by the EPA, having been upgraded in 2019. There is a designated area in the Transfer Station designed to store these materials, to await collection by the EPA’s Hazardous Waste Collection Contractor. A full list of the materials included in this collection contract is below though only a small range is generally stored in the transfer station at any one time.
9.8.1 Transfer Station Table 14 (below) shows a list of possible materials in storage on site in the transfer station hazardous materials compound, at any one time.
Pollutant Location Quantity Storage Comment
Acids TS low HMSA These hazardous materials are stored in approved containers within a hazardous materials storage area. The site is serviced regularly by the EPA’s hazardous materials collection contractor (Cleanaway)
Alkalis TS low HMSA
Arsenic/arsenic based products
TS low HMSA
Batteries (nickel cad/nickel hydride/other)
TS low HMSA
Fire extinguishers (halon/other)
TS low HMSA
Flammable liquids TS low HMSA
Flares/ammunition TS low HMSA
Gas cylinders (propane/other) TS low HMSA
General household cleaners TS low HMSA
Heavy metal compounds TS low HMSA
Hydrocarbons and fuels TS low HMSA
Intractable chemicals TS low HMSA
Light globes (fluorescent/mixed)
TS low HMSA
Smoke detectors TS low HMSA
Organo peroxides TS low HMSA
Oxidising agents TS low HMSA
Paints and varnishes (water/solvent/metal based)
TS low HMSA
PCB materials TS low HMSA
Pesticides (liquid/solid – including organochlorine)
TS Up to 2000 l HMSA
Poisons TS low HMSA
Reactives TS low HMSA
Solvents (halogenated/non halogenated)
TS low HMSA
Toxics TS low HMSA
Pharmaceuticals TS low HMSA
Photographic chemicals TS low HMSA
Unknowns (liquid/solid) TS low HMSA
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 63
PMHC Staff
Small amounts of pesticides/herbicides
TS low Site Container
9.9 Safety equipment
9.9.1 Shower and eyewash station An emergency eyewash and shower equipment is located within 10 m of the hazardous material storage area in the transfer station. Eyewash and shower equipment is maintained and tested on a regular basis.
9.9.2 Safety equipment Appropriate personal protection equipment (PPE) for chemical and hazardous material protection such as hard hats, safety glasses and/or other eye protection, overalls, gloves, chemical splash suits, masks, boots, etc is kept in the site office in the Transfer Station and is accessible. PPE is replaced when necessary. On site staff must inform the Waste Coordinator when PPE supplies are running low so that replacement can be arranged.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 64
THE WAUCHOPE WASTE TRANSFER STATION
Pollution Incident Response Management Plan
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 65
10 THE WAUCHOPE WASTE TRANSFER STATION
The Wauchope Waste Transfer Station is located at 31 Commerce St Wauchope (off King Creek Rd). Note the site does not hold an Environmental Protection Licence and is not required to have a Pollution Incident Response Management Plan (PIRMP). Council has completed this section to provide guidance to staff in the event of an incident. The Facility provides waste management infrastructure to service Wauchope and western PMHC LGA. The Facility services households disposing of car boot and trailer loads of various waste types. Small scale commercial enterprises may utilise the station on occasion, however the majority of commercial and bulk wastes will be transported directly to the Cairncross WMF. All waste deposited onsite will be removed offsite for reuse, resource recovery, processing or will be deposited into the landfill at the Cairncross WMF. Some of the activities that will be undertaken at the Facility are listed below.
Collection and storage of general waste
Recovery of recyclable material prior to delivery to the Cairncross MRF
Processing of green wastes prior to delivery to the Cairncross ORRF
Storage of inert building wastes (concrete and brick)
Collection and storage of waste oil
Hazardous materials storage area
Collection and storage of e-waste for recycling
Collection and storage of mattresses for recycling
Collection and storage of tyres for recycling
Collection and storage of scrap metal for recycling
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 66
10.1 Maps
Figure 1: Location of Facility
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 67
Figure 2: Site Layout
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 68
10.1 Contacts and communication
Table 15
COUNCIL WASTE STAFF – Port Macquarie
Position Name Mobile Contact Contact
Group Manager of Environmental Services
Ashley Grummitt 0403 361 610 6581 8043
Waste Manager Michael Magalhaes 0438 667 492 6581 8125
Waste Services Coordinator Wayne Lenard 0407 417 414 6581 8076
Relieving Waste Services Coordinator/ Team Leader Cairncross
Andrew Collins 0419 419 690 NA
Waste Attendants Wauchope Waste Transfer Station
- 6585 3542
COUNCIL HUMAN RESOURCES STAFF
Safety Coordinator Graham Chandler 0400 818 867 6581 8601
Employee Relations Advisor Brenna Southwell - 6581 8606
10.2 Communicating with neighbours and the local community
The Wauchope Waste Transfer Station is located in the industrial zone in Wauchope. The site has immediate commercial neighbours and nearest rural residential neighbours are located approximately 100m to the north east and south. In the event of an incident the decision to notify neighbours and local communities will be made by the Group Manager Commercial Business Units, with advice from local emergency authorities.
10.3 Minimising harm to persons on the premises
Specific SOPs have been developed for Facility Evacuation for each waste site. These have been attached as Appendix 2.
10.4 Site Details
A list of potential hazards for the Wauchope Waste Transfer Station has been included in Table 16. Refer to the risk management matrix in Table 4.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 69
10.5 Description and likelihood of hazards
Possible pollution incident events associated with the operation of the Wauchope Waste Transfer Station are included in Table 16 below:
Table 16 Risk Description Risk Response Post Response
Severity / Likelihood
Residual Risk Rating
Relevant SOPs
Bushfire Injury to staff or visitors to the site. Early warning and evacuation of site if necessary Rare/minor LOW SOP 11,12,17
Risk of fire spread to within the Waste Facility site.
Fire prevention and sufficient fire fighting capacity Unlikely/major HIGH SOP11-15
Fire in stockpiles/ loads
Injury to staff or visitors to the site.
Early warning and evacuation of site if necessary
Restriction of visitors to affected area
Care taken managing fire, following SOPs
Rare/minor LOW SOP11,17,23
Damage to the environment through air pollution from incineration of treated/ composite timber, hazardous materials area etc.
Fire prevention and sufficient fire fighting capacity
Checking of loads
Rare/moderate MEDIUM SOP9,11-15,24,32
Risk of fire spreading to other parts of the Waste Facility site.
Fire prevention and sufficient fire fighting capacity
Adequate procedures for contractors on site
Rare/minor LOW SOP11-15
Fire in transfer station/ building
Injury to staff or visitors to the site. Early warning and evacuation of site if necessary Rare/major HIGH SOP11,17,23
Air pollution from incineration of hazardous materials, waste, tyres etc.
Fire prevention and sufficient fire fighting capacity
Checking of loads
Rare/moderate MEDIUM SOP9,11-15,24
Pollution of surface water, groundwater through ash or airborne contaminants.
Site inspection and auditing
Surface water controls
Monitoring program
Sediment barriers where necessary
Rare/moderate MEDIUM SOP9,11-15,39
Contamination from stockpile areas.
Surface water controls
Monitoring program
Regular environmental testing
Rare/minor LOW SOP32,38
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 70
Pollution of groundwater
Discharges of contaminants Paint, oil, chemicals etc.
Site inspection and auditing
Surface water controls
Monitoring program
Bunding
Environmental testing when necessary
Rare/moderate MEDIUM SOP18,37-39,45
Contamination from stockpile areas
Correct stockpile management
Site inspection and auditing
Rare/minor LOW SOP32,38
Pollution of surface water
Discharges of contaminants Site inspection and auditing
Surface water controls
Monitoring program
Environmental testing when necessary
Bunding
Rare/moderate MEDIUM SOP18,37-39,45
Contamination from stockpile areas
Correct stockpile management
Site inspection and auditing
Rare/minor LOW SOP32,38
Explosion of gas bottles or storage tanks
Damage to the environment through air pollution
Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP20-22
Spread of fire to other parts of the facility Fire prevention and adequate fire fighting capacity Rare/major HIGH SOP 11-15
Spread of poisonous or odorous gases
Injury to staff or visitors to the site
Early warning and evacuation of site if necessary
Restriction of visitors to affected area
Rare/moderate MEDIUM SOP11,17,23
Damage to the environment
Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP20,21
Spill of chemicals / dangerous materials
Injury to staff or visitors to the site Early warning and evacuation of site if necessary
Restriction of visitors to affected area
Rare/major HIGH SOP17,22,23
Damage to the environment Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP9
Oil spill Damage to the environment Best practice storage and handling of hazardous materials
Site inspection and auditing
Rare/moderate MEDIUM SOP4,9,22
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 71
10.6 Pre-emptive actions to be taken
10.6.1 Site Checks As a part of the Wauchope Waste Transfer Station Operational Environmental Management Plan (OEMP) checks are carried out on site on a regular basis, in order to best manage the site and prevent pollution incidents. Contractors on site are also a part of the process. A copy of the site checks is available in Waste Services SOP 39.
10.6.2 Fire Protection The fire protection systems on site include fire extinguishers, fire hose reels and fire hydrants. All equipment has been installed and are serviced and maintained in accordance with the relevant standards. The location of all fire protection equipment is clearly nominated/labelled so that employees faced with an emergency and under pressure, can confidently locate and select the appropriate type of equipment. The site was designed with bushfire protection in mind given the close proximity to bushland and slope of the land. Defendable zones have been established around the building and a fire access track around the perimeter to allow for sufficient fire-fighting capacity.
10.6.3 Communication System The site office has a phone line and a computer with internet access. A list of emergency phone numbers is clearly displayed at the Facility so they can be seen by both staff.
10.6.4 Security Because of the hazards associated with chemicals and dangerous goods stored within the Transfer Station, and contractors materials on site, access to the facility is controlled and restricted to those persons having a legitimate reason to be on site. Access to the facility by unauthorised persons and unauthorised activities occurring on the site is controlled by security fencing with security locks on all gates, doors and storage containers. Only facility staff shall be able to enter the chemical/hazardous substance storage containers. Signs will be posted in sufficient numbers to be seen from any of the approaches to the storage area with a clear message. Security cameras have been installed in the transfer station area overseeing the site office and drop off points. An alarm system is in place in the office to restrict access. This also has the ability to set off a siren for police, fire, and ambulance related emergencies.
10.6.5 Signs and Labels All hazardous waste storage areas are clearly and individually labelled to indicate which materials are stored in each area. Labels will be in large print and plain English. Signage indicating opening times, access and restricted access requirements has been placed on the exterior of the facility. A list of emergency phone numbers is clearly displayed at a location within the facility that can be seen by both staff and members of the public. Suitable signage indicating the location of fire suppression equipment, first aid kit, eye wash and shower is provided.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 72
10.6.6 Spill Kits It is imperative that the Waste Transfer Station be able to handle any small chemical spill and that all chemical spills receive immediate attention. Spill kits have been provided and located in high-risk areas and are easily identifiable and accessible. Contents include stocks of absorbent material, (e.g. pillows, soil or sawdust “kitty litter”); protective clothing; and secure skips for these materials once they have been used and contaminated.
10.7 Inventory of pollutants on site
The Kew Waste Transfer is expected receive only a small amount of hazardous waste that will be stored in adequate cabinets and bunded storage areas. These material will be transported to the Port Macquarie community resource centre (CRC) regularly.
10.8 Safety equipment
10.8.1 Shower and eyewash station An emergency eyewash and shower equipment is located within 10 m of the hazardous material storage area in the transfer station. Eyewash and shower equipment is maintained and tested on a regular basis.
10.8.2 Safety equipment Appropriate personal protection equipment (PPE) for chemical and hazardous material protection such as hard hats, safety glasses and/or other eye protection, overalls, gloves, chemical splash suits, masks, boots, etc is kept in the site office in the Transfer Station and is accessible. PPE is replaced when necessary. On site staff must inform the Waste Coordinator when PPE supplies are running low so that replacement can be arranged.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 73
11 APPENDICES
APPENDIX 1: Pollution incident response management plan Exercise Evaluation Form
POLLUTION INCIDENT RESPONSE MANAGEMENT PLAN (PIRMP)
EXERCISE EVALUATION FORM Facility:
Date:
Staff on site:
Incident Sequence:
Assessment of significance Yes/No
Time
Initiation of incident response
Cleanup action initiated
Evacuation alarm sounded
Evacuation commenced
Warden checks floor area
Arrive at assembly point
Warden checks for personnel present
Emergency completed
COMMENTS
1. Compliance with SOP’s
2. Competency of Employees
3. Time frames for response
4. General Comments
OBSERVER
SIGNED
Date
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 74
APPENDIX 2: Standard Operating Procedures
STANDARD OPERATING PROCEDURE
SOP17.1: Facility Evacuation Cairncross Waste Management Facility
Purpose and Scope To provide employees with procedures to follow for effective and safe actions in initiating an evacuation of the Cairncross Waste Management Facility. Emergency descriptions
o First Aid Emergency: Area to be supervised/managed, NOT evacuated. Minor
Incident only.
o Minor Emergency: Area ONLY to be evacuated (eg cardiac arrest or other injury
requiring ambulance, minor vehicle incident on site, small spill etc).
o Major Emergency: ENTIRE premises to be evacuated (eg fire, large chemical
release).
Procedure/Standard/Policy 1. The Chief Warden determines the need for evacuation. For Cairncross the Chief
Warden is (in priority order, according to availability):
the Waste Coordinator,
the Cairncross Team Leader,
Weighbridge Attendant.
Note: Evacuation control will be coordinated from the weighbridge.
Area Wardens are responsible for notifying staff & visitors and clearing their area. Area Wardens for Cairncross are:
Landfill staff,
The Weighbridge Attendant,
Remondis Branch Manager (or Operations Manager in his absence),
JR Richards MRF Manager (or Assistant manager in his absence).
2. Staff in proximity to an incident/accident/threat must check for danger and notify
the Chief Warden and nearest Area Warden. The Chief Warden or nearest Area
Warden must contact by telephone the emergency services by dialling ‘000’
providing all information they require, including:
Indicate the service required (police, ambulance or fire services)
Wait to be connected to the service operator
Answer all questions
Stay on the line until requested to hang up.
You will be asked the following:
Facility address: 8395 Pacific Hwy Telegraph Point
Facility phone number: 6585 0738
Facility nearest intersection: Bill Hill Rd and Pacific Hwy
Information about the patient’s medical condition
3. The Area Warden/Chief Warden in attendance must sound the evacuation alarm
and/or provide evacuation advice to all personnel and facility users on site.
Minor Emergency: In the event of a Minor Emergency, three (3) short Air
Horn blasts will be used to provide immediate communication to all
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 75
staff/visitors. Air Horns are located in the Weighbridge and Council staff
shed.
Major Emergency: In case of a Major Emergency, one (1) long Air Horn
blast (at least 30 seconds) is used to inform staff and contractors about
emergency status.
Note: The Area Wardens/Chief Warden must also notify each other by two-way radio or phone to ensure all areas are accounted for.
4. The Chief Warden will notify Area Wardens in other site areas (Landfill,
Weighbridge, MRF and ORRF). These Area Wardens are responsible for directing
staff and visitors in their areas to the Emergency Assembly Area 1 (pull off area
and grass near the weighbridge, towards the MRF). Landfill staff must evacuate
the stockpile area and Council staff shed.
5. The Chief Warden will initiate measures to restrict vehicles entering the facility.
6. The Chief Warden will determine safe evacuation routes and directs personnel and
facility users to Emergency Assembly Area 1. Refer to attached Emergency
Evacuation Plan.
7. If Landfill staff or any visitors to the stockpile area cannot access Emergency
Assembly Area 1 due to the nature of the emergency (ie unsafe area between the
landfill and the weighbridge), they should proceed to the Emergency Assembly
Area 2 (Site Shed within stockpile area). Refer to attached Emergency Evacuation
Plan. In this situation contact must be made to notify staff, contractors and
customers at this side of the facility.
8. Upon arrival at the Emergency Assembly Area 1 the Chief Warden must;
o Notify, by telephone, the Waste Coordinator (if not already in attendance)
or Group Manager Commercial Business Units of the incident and provide
an update of the action initiated to date.
o Confirm the presence or otherwise of all personnel.
o Determine the suitability of the Emergency Assembly Area 1. If
necessary initiate movement to Emergency Assembly Area 2.
o Upon their arrival brief the emergency services including the status of the
facility personnel.
o If necessary coordinate the movement of personnel to the Emergency
Evacuation Assembly Area (Charlie Watts Sportsground, Telegraph
Point). Refer to attached Emergency Evacuation Plan.
o Upon arrival, brief the Waste Coordinator or and/or Group Manager
Commercial Business Units about the incident and provide an update of
the action initiated to date
Note: Under no circumstances are staff to endanger their own safety during the course of a facility evacuation.
As soon as possible after the incident, staff are to complete all relevant incident reporting and participate in an incident review
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 76
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 77
STANDARD OPERATING PROCEDURE
SOP17.3: Facility Evacuation Wauchope Transfer Station
Purpose and Scope To provide employees with procedures to follow for effective and safe actions in initiating an evacuation of the Wauchope Transfer Station. Emergency descriptions
o First Aid Emergency: Area to be supervised/managed, NOT evacuated. Minor
Incident only.
o Minor Emergency: Area ONLY to be evacuated (eg cardiac arrest or other injury
requiring ambulance, minor vehicle incident on site, small spill etc).
o Major Emergency: ENTIRE premises to be evacuated (eg fire, large chemical
release).
Procedure/Standard/Policy 1. The Chief Warden checks for danger and determines the need for evacuation. For
Wauchope the Chief Warden is the Transfer Station Attendant.
2. The Chief Warden is to contact by telephone the emergency services by dialling ‘000’
providing all information they require, as follows:
Indicate the service required (police, ambulance, fire services
Wait to be connected to the service operator
Answer all questions
Stay on the line until requested to hang up.
You will be asked the following:
Facility address: 31 Commerce St, Wauchope
Facility Phone number: 6585 3542
Facility nearest intersection: King Creek Road
Information about the patient’s medical condition
3. The Chief Warden must notify all staff and visitors on site and direct them to the
Emergency Assembly Area (grass area adjacent to the front gate). Refer to
Emergency Evacuation Plan.
4. The Chief Warden will initiate measures to restrict vehicles entering the facility.
5. Upon arrival at the Emergency Assembly Area, the Chief Warden must;
o Notify, by telephone, the Waste Coordinator or Group Manager Commercial
Business Units of the incident and provide an update of the action initiated to
date.
o Confirm that all visitors are accounted for.
o Determine the suitability of the Emergency Assembly Area 1. Should the
Emergency Assembly Area be deemed to be unsuitable or unsafe the Chief
Warden is to direct staff and facility users to the Emergency Evacuation
Assembly Area 2 (Council Depot, north on Commerce Street). Refer to
Emergency Evacuation Plan.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 78
o Upon arrival, brief the emergency services including the status of the facility
personnel.
o Coordinate the movement of visitors to the Emergency Evacuation
Assembly Area if necessary.
o Upon arrival, brief the Waste Coordinator or and/or Group Manager
Commercial Business Units about the incident and provide an update of the
action initiated to date.
Note: Under no circumstances are staff to endanger their own safety during the course of a facility evacuation.
6. As soon as possible after the incident, staff are to complete all relevant incident
reporting and participate in an incident review.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 79
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 80
STANDARD OPERATING PROCEDURE
SOP17.4: Facility Evacuation Dunbogan Landfill
Purpose and Scope To provide employees with procedures to follow for effective and safe actions when on site at the Dunbogan Landfill. Emergency descriptions
1. First Aid Emergency: Area to be supervised/managed, NOT evacuated. Minor
Incident only.
2. Minor Emergency: Area ONLY to be evacuated (eg cardiac arrest or other injury
requiring ambulance, minor vehicle incident on site, small spill etc).
3. Major Emergency: ENTIRE premises to be evacuated (eg fire, large chemical
release).
Procedure/Standard/Policy 4. The Warden checks for danger and determines the need for evacuation. For
Dunbogan the Chief Warden is the waste staff member on site. In the event of only
one person being onsite that isn’t a waste staff member, they are to evacuate the site
and immediately contact the Waste Coordinator. The Waste Coordinator then takes
the role of the Warden.
5. The Warden is to contact by telephone the emergency services by dialling ‘000’
providing all information they require, as follows:
Indicate the service required (police, ambulance, fire services
Wait to be connected to the service operator
Answer all questions
Stay on the line until requested to hang up.
You will be asked the following:
Facility address: The Boulevarde, Dunbogan
Facility Phone number: 6559 5741
Facility nearest intersection: Scarborough Way
Information about the patient’s medical condition
6. The Warden will direct any others on site to the Emergency Assembly Area 1 (front
gate area near site office). Refer to Emergency Evacuation Plan.
7. Upon arrival at the Emergency Assembly Area the Warden must;
o Notify, by telephone, the Waste Coordinator or Group Manager Commercial
Business Units of the incident and provide an update of the action initiated to
date.
o Notify the Sewerage Treatment Plant as per the attached contact list.
o Confirm that all visitors are accounted for.
o Determine the suitability of the Emergency Assembly Area 1. Should the
Emergency assembly area be deemed to be unsuitable or unsafe the Chief
Warden is to direct staff and facility users to exit the site and travel east via
Scarborough Way to the Emergency Assembly Area 2 (Dunbogan Reserve, off
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 81
the Boulevarde Dunbogan at the junction of the Camden Haven River and the
inlet to Googley’s Lagoon). Refer to Emergency Evacuation Plan.
o Upon arrival, brief the emergency services including the status of the facility
personnel.
o Upon arrival, brief the Waste Coordinator or and/or Group Manager Commercial
Business Units about the incident and provide an update of the action initiated to
date.
Note: Under no circumstances are staff to endanger their own safety during the course of a facility evacuation.
8. As soon as possible after the incident, staff are to complete all relevant incident
reporting and participate in an incident review.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 82
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 83
STANDARD OPERATING PROCEDURE
SOP17.5: Facility Evacuation Kew Transfer Station
Purpose and Scope To provide employees with procedures to follow for effective and safe actions in initiating an evacuation of the Kew Transfer Station. Emergency descriptions
o First Aid Emergency: Area to be supervised/managed, NOT evacuated. Minor
Incident only.
o Minor Emergency: Area ONLY to be evacuated (eg cardiac arrest or other injury
requiring ambulance, minor vehicle incident on site, small spill etc).
o Major Emergency: ENTIRE premises to be evacuated (eg fire, large chemical
release).
Procedure/Standard/Policy 7. The Chief Warden checks for danger and determines the need for evacuation. For
Kew the Chief Warden is the Transfer Station Attendant.
8. The Chief Warden is to contact by telephone the emergency services by dialling ‘000’
providing all information they require, as follows:
Indicate the service required (police, ambulance, fire services
Wait to be connected to the service operator
Answer all questions
Stay on the line until requested to hang up.
You will be asked the following:
Facility address: 79 Herons Creek Road, Kew
Facility Phone number: 02 6559 4983
Facility nearest intersection: Nancy Bird Walton Drive and Herons Creek
Road
Information about the patient’s medical condition
9. The Chief Warden must notify all staff and visitors on site and direct them to the
Emergency Assembly Area (front entrance of facility). Refer to Emergency
Evacuation Plan.
10. The Chief Warden will initiate measures to restrict vehicles entering the facility.
11. Upon arrival at the Emergency Assembly Area, the Chief Warden must;
o Notify, by telephone, the Waste Coordinator or Group Manager Commercial
Business Units of the incident and provide an update of the action initiated to
date.
o Confirm that all visitors are accounted for.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 84
o Determine the suitability of the Emergency Assembly Area 1. Should the
Emergency Assembly Area be deemed to be unsuitable or unsafe the Chief
Warden is to direct staff and facility users to the Emergency Evacuation
Assembly Area 2 (Kew Information Centre). Refer to Emergency Evacuation
Plan.
o Upon arrival, brief the emergency services including the status of the facility
personnel.
o Coordinate the movement of visitors to the Emergency Evacuation
Assembly Area if necessary.
o Upon arrival, brief the Waste Coordinator or and/or Group Manager
Commercial Business Units about the incident and provide an update of the
action initiated to date.
Note: Under no circumstances are staff to endanger their own safety during the course of a facility evacuation.
12. As soon as possible after the incident, staff are to complete all relevant incident
reporting and participate in an incident review.
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 85
Table 1: Emergency contact details
EMERGENCY COMBAT AND SUPPORT AGENCY CONTACT DETAILS
Name Organisation Contact
NSW Fire Brigade Fire and Rescue NSW (reporting pollution) Port Macquarie Fire Station Wauchope Fire Station Laurieton Fire Station
000 or 1300 729 579 65810520 6585 2161 6559 9127
NSW Rural Fire Service Rural Fire Service – Mid North Coast Region
000 or 6588 9000
NSW Police Service Port Macquarie Police Station 000 or 6583 0199
NSW Ambulance Service
Port Macquarie Ambulance Station 131233
Environment Protection Agency (EPA)
Pollution Incidents – Environment Line 131 555
Coffs Harbour Regional Office 6659 8298
NSW Department of Health
Mid North Coast Local Health District Port Macquarie Office
1800 726 997
SafeWork Authority Port Macquarie Office 24 hour hotline
6588 7000 131050
National Parks and Wildlife Services (NP&WS)
Parks and Wildlife Mid North Coast Regional Office
6588 5555
Local Hospital Port Macquarie Base Hospital 02 5524 2000
Department of Primary Industries (NSW Fisheries)
Port Macquarie Office (Acacia Ave) 5524 0600
Poisons Information Hotline
Westmead Hospital 131126
State Emergency Service
Port Macquarie SES (General) Flood and Storm
6581 0150 132 500
Department of Families and Community Services
Port Macquarie Community Services 6583 3622
Roads & Maritime Services
Port Macquarie District Office 132213
Bureau of Meteorology Land weather and flood warnings NSW 02 9296 1555
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 86
Table 2: Council Staff Contact Details
COUNCIL WASTE STAFF
Position Name Mobile Contact Contact
Group Manager Commercial Business Units
Ashley Grummitt 0403 361 610 6581 8043
Waste Manager Michael Magalhaes
0438 667 492 6581 8125
Waste Services Coordinator Wayne Lenard 0407 417 414 6581 8076
Relieving Waste Services Coordinator/ Team Leader Cairncross
Andrew Collins 0419 419 690 -
Weighbridge Attendants Cairncross Glenn Twaddell Paul Cini
- 6585 0738
Waste Transfer Station Attendants Port Macquarie
Paul Dymock Craig Smith
6581 4817
Kew Waste Facility Attendants Colin Applegate Steve Watson
6559 5741
Weighbridge Attendants Wauchope Terry Jefferies Ray Cheeseman Anthony Magnoli
6581 4817 -
COUNCIL HUMAN RESOURCES STAFF
Safety Coordinator Graham Chandler 0400 818 867 6581 8601
Employee Relations Officer Brenna Southwell - 6581 8606
Port Macquarie-Hastings Council - Pollution Incident Response Management Plan 2020
Page 87
EMERGENCY FLOWCHART
Minor Emergency Major Emergency
Responsibility of all staff Recognize
Recognize the emergency quickly
Check for danger
Determine the extent of the emergency React
Communicate / Signal fellow employee, Supervisor or Senior Manager
Advise nature of Emergency and situation Chief Warden or Area Warden to sound alarm as follows
o Three short whistle blasts to Minor emergency or one long blast (30 seconds) for Major emergency*
*Not necessary at Wauchope Transfer Station due to size of site
Direct Area evacuation
Ascertain incident and patient details and status
Call emergency services if necessary. DO NOT hang up before they do
Arrange supporting staff to control the public
Check for dangers and respond if safe
Administer first aid / assistance as necessary as per SOP 23.
Provide update of the emergency and patient
status to emergency services
Complete necessary reports thoroughly
Direct Facility evacuation
Ascertain incident and patient details and status
Call emergency services. DO NOT hang up before they do
Arrange area staff to evacuate areas
Establish appropriate emergency action
procedures
Responsibility of area wardens
Clear the area
Direct staff/ visitors to the designated emergency assembly areas
Complete relevant area search
Assist the first staff member with the emergency response and first-aid treatment as per SOP 23.
Complete necessary reports thoroughly
Responsibility of area wardens
Clear the area
Direct staff/ visitors to the designated emergency assembly areas
Complete relevant area search
Assist the first staff member with the emergency response and first-aid treatment
Complete necessary reports thoroughly
Responsibility of chief warden
Direct area evacuation
Account for personnel (Evacuation List)
Ascertain incident and patient details and
status
Meet emergency services and direct to emergency site
Evacuate site if necessary – direct all staff and visitors to safe evacuation routes and post evacuation assembly point
Provide debriefing to staff
Allow staff/ visitors back into the facility once emergency is given the all clear
Complete necessary documentation and
reports, and coordinate incident review
Responsibility of chief warden
Direct area evacuation
Account for personnel at emergency assembly areas (Evacuation List)
Ascertain incident and patient details and
status
Meet emergency services and direct to emergency site
Provide debriefing to staff
Allow staff/ visitors back into the facility once emergency is given the all clear
Complete necessary documentation and
reports and coordinate incident response
review