Polyethylene Pipe Systems COMMUNICATIONS DUCTING PRODUCT CATALOGUE www.watersandfarr.co.nz 0800 923 7473 Issue: February 2017
Transcript

Polyethylene Pipe Systems

COMMUNICATIONS DUCTINGPRODUCT CATALOGUE

www.watersandfarr.co.nz 0800 923 7473

Issue: February 2017

PO Box 13329OnehungaAuckland, New ZealandP 0800 923 7473F +64 9 622 4037www.watersandfarr.co.nz

Information or advice contained in this catalogue or obtained from Waters & Farr otherwise is given in good faith. Waters & Farr make no warranty or representation regarding the information, opinions and recommendations contained in this catalogue. Users of this catalogue are advised to seek and rely upon their own professional advice and assessment of the matters contained in this catalogue. Waters & Farr excludes all liability to any user of this catalogue for consequential or indirect damages, or any other form of compensation or relief whatsoever for any acts or omissions of Waters & Farr, arising out of or in connection with the use of this catalogue irrespective of whether the same arises at law, inequity or otherwise.

ABOUT WATERS & FARR

Established in 1954, Waters & Farr is a leading manufacturer of polyethylene and polypropylene pipes for infrastructure and rural application. Overview

Manufacturing plants in Whanganui and Rangiora supported by distribution centres in Auckland, Whanganui and Christchurch supply our merchant and utilities customers with product throughout New Zealand. Over three hundred merchant stockists ensure stock is readily available for contractors, farmers and other end users.

Waters & Farr is always looking to the future. Plant upgrades have seen modern extrusion lines installed with higher outputs, jacket and stripe capability, and a range extension to 1200 mm diameter.

Commitment to quality

� Waters & Farr maintain quality management system certification to ISO9001 standard.

� ‘S’ mark certification to AS/NZS 4130 and AS/NZS 5065 is maintained with a third party.

� Pipe Test NZ, a division of Waters & Farr, was established as an independent testing laboratory. It is accredited by IANZ to conduct tensile, pressure, reversion and joint testing for Waters & Farr, and third party pipe, electrofusion and butt weld testing.

� Waters & Farr follow founding policies that underpin commitment and performance outcomes to achieve our vision & values.

How To Find Us Waters & Farr Terms and Conditions

PRODUCT ATTRIBUTES W

&F

Com

mun

icat

ions

Duc

ting

Pro

duct

Cat

alog

ue |

Feb

ruar

y 2

017

PR

Od

UC

T A

TTR

iBU

TES

4

PRODUCT ATTRIBUTES

WATERS & FARR PRODUCTS INCLUDE: � Inert, corrosion free pipe material � Low specific weight � Low installation and maintenance costs low � Leak free welded construction � Good resistance to impacts, ground movement � High strength, durability and abrasion resistance � Flexibility � Long design life � Note: Supply on drums Ducting is produced to the same standard as pressure pipe for wall thickness and ovality. However, it is our experience that some sagging and ovality of the material may occur, particularly in the larger sized of ducting, due to the heavier weight of long coils.

� “Polyethylene pipe is widely recognized as having good seismically resilient properties, which is supported by its performance in the 2010/2011 Canterbury earthquakes and earthquakes around the world.”

Source: SEISMIC PERFORMACE OF PLASTIC PIPE SYSTEMS IN 2010/11 CANTERBURY EARTHQUAKES by Bill Noell, Water Services Infrastructure Lead, Pattle Delamore Partners.

DIMENSIONS: POLYETHYLENE DUCTING

DIMENSIONS TO AS/NZS 4130

Standard dimension Ratio SdR 13.6 SdR17 SdR21 SdR26

dN/Od duct outside diameter (Od)

Mean wall thickness

Mean inside diameter

Mean wall thickness

Mean inside diameter

Mean wall thickness

Mean inside diameter

Mean wall thickness

Mean inside diameter

20 20.0 20.3 1.8 16.6 — — — — — —

25 25.0 25.3 2.1 21.0 — — — — — —

32 32.0 32.3 2.6 26.9 2.1 28.0 — — — —

40 40.0 40.4 3.2 33.8 2.6 35.0 — — — —

50 50.0 50.5 4.0 42.3 3.2 43.8 — — — —

63 63.0 63.6 5.0 53.3 4.1 55.2 3.2 56.9 — —

75 75.0 75.7 5.9 63.6 4.8 65.7 3.9 67.6 — —

90 90.0 90.9 7.0 76.4 5.8 78.9 4.6 81.2 3.8 82.9

110 110.0 111.0 8.6 93.3 7.0 96.5 5.7 99.2 4.6 101.3

125 125.0 126.2 9.8 106.1 7.9 109.9 6.4 112.9 5.1 115.4

140 140.0 141.3 10.9 118.8 8.8 123.0 7.1 126.4 5.8 129.1

160 160.0 161.5 12.5 135.8 10.1 140.6 8.2 144.4 6.6 147.5

Ducting: communications

W&

F C

omm

unic

atio

ns D

uctin

g P

rodu

ct C

atal

ogue

| F

ebru

ary

201

7

d

UC

TiN

g: C

OM

MU

NiC

ATi

ON

S

5

DUCTING: COMMUNICATIONS

GREEN DUCTING COILS HDPE

item Code SizedN/Od (mm)

SdR Average inside diameter (mm)

Coil Length (m)

DG20.9.200 20 9 15.1 200

DG32.13.200 32 13.6 26.9 200

DG32.13.500 32 13.6 26.9 500

DG32.13.1000 32 13.6 26.9 1000

DG40.17.200 40 17 35.0 200

DG50.17.100 50 17 43.8 100

DG63.17.100 63 17 55.2 100

DG90.17.100 90 17 78.9 100

DG110.17.100 110 17 96.5 100

item Code SizedN/Od (mm)

SdR Average inside diameter (mm)

Coil Length (m)

DR20.13.200 20 13.6 16.7 200

DR50.17.100 50 17 43.8 100

DR110.17.100 110 17 96.5 100

► Ducting is not pressure pipe, it is produced however consistent with dimensions of AS/NZS 4130

► Delivery is available in coils, on drums and in cut lengths, subject to diameter and wall thickness

► Ducting can be produced in solid green, black with green stripe, green jacketed black pipe or to special order.

RED DUCTING COILS HDPE

► Delivery is available in coils, on drums and cut lengths, subject to diameter and wall thickness

► Ducting can be produced in solid red, black with red stripe, red jacketed black pipe or to special order.

DUCTING: COMMUNICATIONS W

&F

Com

mun

icat

ions

Duc

ting

Pro

duct

Cat

alog

ue |

Feb

ruar

y 2

017

dU

CTi

Ng

: C

OM

MU

NiC

ATi

ON

S

6

Ducting: communications

W&

F C

omm

unic

atio

ns D

uctin

g P

rodu

ct C

atal

ogue

| F

ebru

ary

201

7

d

UC

TiN

g: C

OM

MU

NiC

ATi

ON

S

7

TRUCK CAPACITY PE100 PIPE FTL

Pipe Outside diameter

Unit kg / m(PN10)

Unit Weight (PN10)

Qty Weight (kg)

*15 100m 0.076 7.6 250 coils 1,900

*20 100m 0.1119 11.19 250 coils 2,798

25 100m 0.124 12.4 250 coils 3,100

32 100m 0.186 18.6 250 coils 4,650

40 100m 0.295 29.5 125 coils 3,688

50 100m 0.454 45.4 125 coils 5,675

63 100m 0.724 72.4 125 coils 9,050

75 100m 1.021 102.1 20 coils 2,042

90 100m 1.469 146.9 20 coils 2,938

110 100m 2.185 218.5 20 coils 4,370

125 100m 2.788 278.8 20 coils 5,576

140 100m 3.499 349.9 20 coils 6,998

110 14m 2.185 30.6 324 9,911

125 14m 2.788 39.0 256 9,992

140 14m 3.499 49.0 196 9,601

160 14m 4.5677 63.9 144 9,208

180 14m 5.7783 80.9 121 9,788

200 14m 7.129 99.8 100 9,981

225 14m 9.0429 126.6 81 10,255

250 14m 11.0823 155.2 64 9,930

280 14m 13.923 194.9 56 10,916

315 14m 17.631 246.8 36 8,886

355 14m 22.4364 314.1 25 7,853

400 14m 28.357 397.0 25 9,925

450 14m 35.9287 503.0 16 8,048

500 14m 44.258 619.6 16 9,914

560 14m 55.6126 778.6 9 7,007

630 14m 70.2675 983.7 9 8,854

710 14m 89.3688 1251.2 4 5,005

800 14m 113.3218 1586.5 4 6,346

900 14m 143.8259 2013.6 4 8,054

1000 14m 177.1649 2480.3 4 9,921

1200 14m 243.9462 3415.2 1 3,415

* Weights for ND 15-20 are based on PN16. PN12 Note: table is based on FTL with timber dunnage, adjustments may be required for Ferry, Curtainside trucks, where shipment height can exceed 2.2m or on private roads

Colour Common Use

Blue Potable Water

Orange Electrical Conduit

Yellow Gas PE100

Light Yellow Gas PE 80

Green Rural/Raw Water

Purple Reclaimed Water

Cream Pressure Sewer

Light Green Communication

Light Grey Communication

Red Fibre optic

This table is guide, refer AS/NZS 4130 as to correct RAL colour codes and stripe/jacket format for pressure pipes. Waters and Farr is able to supply pipe either solid colour, or with a colour jacket or striped as per standard.

www.watersandfarr.co.nz 0800 923 7473

Polyethylene Pipe SystemCommunications Ducting Product Catalogue

Issue: February 2017


Recommended