COOLING TOWER VENTILATION MINE VENTILATION FORCED DRAFT FAN ~ , INDUCED DRAFT FAN -c--coc ._, J'L -' L ~ ---T:'''--'''''''-''~ c Power-Flow@ Silencers noise control for gas handling and heavy duty air systems Gas Turbines Compressors Diesel Engines Cooling Towers Mechanical Draft Fans Air Cooled Condensers Scrubbers Power Plants Wind Tunnels Dust Collectors Furnace Exhaust Engine Test Cells Incinerators Refineries Steel Mills Test Facilities Tunnel Ventilation Jet Fans Chemical Process Plants --.AnyAir/Gas Handling Installation ~ - 0 0 0 oi z >= "' -' -' :J '" INDUSTRIAL ACOUSTICS COMPANY
Transcript
Page 1: Power Flow Silencers

COOLING TOWER

VENTILATION

MINE VENTILATION

FORCED DRAFT FAN

~

,

INDUCED DRAFT FAN

-c--coc ._,

J'L -' L ~ ---T:'''--'''''''-''~

cPower-Flow@Silencersnoise control for

gas handling andheavy duty air systems

Gas Turbines

Compressors

Diesel Engines

Cooling TowersMechanical Draft Fans

Air Cooled Condensers

Scrubbers

Power Plants

Wind Tunnels

Dust Collectors

Furnace Exhaust

Engine Test CellsIncinerators

Refineries

Steel Mills

Test Facilities

Tunnel Ventilation

Jet Fans

Chemical Process Plants

--.AnyAir/Gas Handling Installation

~-000oi

z>="'-'-':J'"INDUSTRIALACOUSTICSCOMPANY

Page 2: Power Flow Silencers

'-CPower-FlowSilencersMeet the most demanding requirements in

Noise Control for Gas and Air Flow Systems

IndustrialAcousticsCompany- thepioneeringleaderinaero-acousticnoisecontrol- hasmore thanfour decadesof experience in the design and manufacture of silencers for jet engines, gas turbines, forced draft fans and airhandling systems. The result is an ex/ensive range of standard silencer configurations incorporating innovativedesign and manufacturing features withperformance certified in lAC's Aero-Acoustic NVLAP-Certified Laboratory.

Performance ratings for both Dynamic Insertion Loss and Aerodynamic Pressure Drop for all Power-FlowSilencer designs have been certified in accordance with ASTM E 477 and applicable sections of ISO 7235:1991and British Standard 4718-1971 in our full-scale wind tunnel and corroborated by independent laboratories.

Take advantage of lAC's know-how...the most extensive in the noise control industry. Special silencerconfigurations are available to satisfy the most stringent criteria.

RECTANGUlAR

...For applications ranging from highway tunnel andmineventilation to cooling tower silencing, rectangularparallel baffle silencers offer the greatest flexibility inoptimizing acoustical and aerodynamic performance.Catalog data is published for over 50 standard con-figurations. Request PFS Data Sheets

CYliNDRICAl

...For circular ducts/stacks and axial fan inlet and dis-

charge, tubular siiencers provide minimum turbulenceand pressure drop. Catalog data is published for over90 configurations. Request PFDS Data Sheets.

STACKINSERT

...For existing stacks in-serts provide economicaland effective sound at-tenuation. Stack insertsare available in traditional'bullet" designs, ACFI(ACoustic Filter) for dirtygas streams and parallelbaffle arrangements.Request Bulletin 4.0009

SIDEINlETANDINlETBOX

...For direct connection without transitions side inlet

and inlet box silencers save space and reduce cost.

~

OCOPYRIGHT 1989. REVISED9-96. LASTPRINTED4-00 BY INDUSATIALACOUSTiCS COMPANY,INC.

Page 3: Power Flow Silencers

ELBOW

...For turning sec-tions in otherwisewasted space com-pact silencers withcurved asymmetricalair passages optimizeaerodynamic andacoustical perform-ance.

STRAIGHT-THRULOWPRESSUREDROP

'...For material conveying systems and en-gine exhausts the straight-through designprovides sound attenuation with pressuredrops hardly more than the pipe section itreplaces.

SPECIAL

IU

...For limited space, tough acoustical andaerodynamic requirements and corrosiveenvironments lAC will develop special de-signs to suit.

Power-FlowSilencersareavailableinthesesound-absorptivedesigns:

Dissipative(Cylindrical shown) silencers provide broad-bandsound attenuation with absorptive fill materials protected by perforatedplates.

ACFI(ACoustic Filter - Rectangular shown) silencers use clog-resis-tant tuned cavities in contaminated gas stream processes that canquickly clog conventional parallel baffle silencers. Request Bulletin4.0010

Fiber-Free*(Rectangular shown) silencers are parallel baffle de-signs without fill of any kind. Access doors are provided so that baffleinteriors can be completely cleaned of contaminants.

l'

'US. Patent No. 4287962

Page 4: Power Flow Silencers

THElACAERO-ACOUSTlClABORATORYIS ONCAn TODEMONSTRATESPECIFICATIONCOMPLIANCEANDSILENCERPERFORMANCE

lAC silencer design is based on state-of-the-art matrix-driven computational programs which minimizedesign time and eliminate costly field-performance deficiencies. However, in critical applications, it isessentialto demonstratesilencerperformanceinanaero-acousticlaboratorywithNVLAPaccreditation forthe ASTM E 477 Standard.

lAC's Aero-Acoustic Research Center permits forward- and reverse-flow dynamic-insertion-loss, self-noise, and pressure-drop rating of silencers and other characteristics in a closed-loop wind tunnel. Dual reverberation rooms permit testrng of system componentssuch as wall panels, doors, windows and assembled air handling units.

Customers, specifying engineers, and acoustical consuitants arealways welcome in the lAC laboratory. Contact us toarrange inspection and witnessedtesting programs.

22,000 cfm (33,98Om3Ihr) AIR HANDLINGUNIT UNDER TEST IN lAC 10,000 f13

(283m3) REVERBERANT ROo1J\.

r:.n<;\/?(] r;;...

~ACCREDITED BY THE NATIONAL INSISTUTE OF STANDARDS

lI\.I '(J l.l,~ AND TECHNOLOGY, NATIONAL VOLUNTARY LAB ACCREDITA-TION PROGRA..,J'OR ACOUSTICAL TESTING SERVICES

NOISHIELD" LOUVERSRequest Bulletin 1,0502

QUIET-DUCT"' SILENCERS MODULlNE" FAN ENCLOSURERequest Bulletin 1,0301 Request Bulletin 6-0701

NOISHIELD'" BARRIERS

Request Bulletin 6,0016

cUnited KingdomlAC House, Moorside Road,WINCHESTER,Hampshire, S023 7USTel: +44(0) 1962 873000Fax: +44(0) 1962873111E-mail: [email protected]: www.iacl.co.uk

TECHNICAL REPRESENTATION IN PRINCIPAL CrnES THROUGH THE WORLD

GermanySohlweg 17,D-41372 Niederkruchten

Tel: (02163) 99910Fax: (02163) 999123E-mail: [email protected]: www.iac-gmbh.de

United States1160 Commerce AvenueBronx, New York 10462-5599Tel: (718) 931-8000Fax: (718) 863-1138E-mail: [email protected]: www.industrialacoustics.com

Pri,ted ;, USA

-~


Recommended