Energy ManagementAt Your Fingertips

ELM COR V2 0614

Today’s Energy Challenge

demand forefficiency

supply costs

+

need forsustainability

+

global demand for energyenergy prices

increase in the world’s electricity demand will be from India between2011 - 2035.

will be spent on global investment in the power sector between2013 and 2035.

* Source: World Energy Outlook 2013 Factsheet

13%*

$17 trillion*

Global trends willdirectly impact youand your businessunless you can improve energy efficiency

adapt to new environment regulations

reduce your environment footprint

ElMeasureTM is a leading provider ofCustom Energy Management Solutions,globally.

We help industries reduce energy wastage through awide range of products to suit diverseenergy management needs.

Let our energy experts find thebest services for you.

We support you at every stage of theenergy management lifecycle, through

expert strategy

broad offering of energy efficiency services

best return on investment (ROI) plans

efficient monitoring and controlling of your energy

in-depth analysis of your cost saving

Our high level of reliability and productivitystems from

post sales support

online support

ISO 9001:2008 certification

CE certified by TUV

world class research, development and design team

Discover our complete solutions offering

building energy management system

demand monitor and control

energy billing system

prepaid metering solutions

energy audit solutions

test bench systems

motor protection system

generator monitoring unit

light management system

battery management system

water management system

Discover our complete product offering

energy management software

prepaid energy meters

demand controller and monitors

high profile power analyzers

multifunction digital energy meters

dual source energy meters

digital panel meters

power factor controllers

earth leakage relays

RF modems

GSM modems

aggregators

multi-channel load managers

smart plugs

power distribution units

control relay unit for PDU

transducers

power & energy transducers

RS485 to RS232/ethernet/optic fiber

converters

Everyone has WASTAGES – Difference being “How Big”

or “How Small”

Everyone has WASTAGES – Difference being “How Big”

or “How Small”

We can only SAVE what we Waste, not what we Need

We can only SAVE what we Waste, not what we Need

We can only SAVE what we can MEASURE

We can only SAVE what we can MEASURE

Energy Management – Simple Truths

Android Apps

Web Solution Remote Monitoring

Other Make Integration LAN View

Basic solution

Technology Advancement

Hurdles / Major Issues

• Breakdowns, Process Interruptions• Frequent Equipment Tripping / Equipment Deterioration• Equipment inefficiency

• Energy Cost Vs. Production/ Utilization / Loss• Raise in Energy Cost adding to Production Cost• Production Loss• CAPEX Decision

• Manpower Planning• Accurate MIS Reporting/ Decision Making• Productivity Study/ Control

ElMeasure Approach – Energy Management System

Local

Remote

Monitoring Methods

Graph DisplayBench Marking

Reporting Limit Value Monitoring

Trending Chart Display

Tools

EMS SolutionsEnergy Balancing

Productivity Study

Equipment Efficiency Study

Economic Power Purchase

Equipment Deterioration Study

Load Shifting, Staggered start/stop

Power factor Study/ Management

Demand Management

Idle Equipment Study

EMS Communication Model

Multifunctional Meters SensorsBilling Meter

Gateway

Internet

Local Monitoring

Remote Monitoring

Wired Wireless

Energy Management System

Economic Power Purchase

PF Management

Demand Management

Equipment Efficiency Study

Energy Balancing

Load Shedding

Alerts

Customized Features

• Analyzes Peak and Non Peak hour of the day

• Enables to run equipment/process when the Energy

Tariff is minimum

• Gives an idea to Plant Manager in planning the

production schedule & implementing load shifting

• Start / stop of equipment should be planned such that

the contract power demand fixed Energy Supply

Company is not overshot.

Time Of Day

Economic Power PurchaseEconomic Power Purchase

Power Factor Management

Low PF causes detrimental effects on

equipments & reduce the equipment efficiency

• Online Power factor monitoring

• Avg PF report enables user to take

necessary correct action if required

• Good Power quality results - enhanced

performance of equipment

PF Management

Demand Management

Benefits

• Energy reports assists to eliminate Demand Spikes

• Programmable Forecast Demand setting

• Ensures that demand not to exceed the sanction demand

• Avoids under utilization of the sanctioned demand

Monitoring & Controlling

• Demand peaks with Time stamp can be identified. Events

can be studied and related with the production events

• Enables user to program threshold values of max demand

and initiate alarm / cut-off when demand surpasses

threshold values.

Demand Management

Equipment Efficiency

• Preventive maintenance based on Design Vs Actual

specifications

• Audio/Visual alarm - generated when the equipment

exceeds it threshold values

• Reduces equipment/plant down time

• Monitoring equipment performance to avoid wasteful

usage of Energy

• Equipment of similar rating can be compared against

each other with one equipment running under ideal

condition is taken as reference.

Equipment Efficiency Study

Energy Balancing

Energy Balancing

Energy Balancing essential to determining the Energy loss between Incomer and distribution loads.

Provides accurate energy loss details for design and operations.

Necessary action can taken to cut down losses.

INCOMER

FEEDERS

Power Util

ized

EB Power

Losses

Load Shedding

• Helps in optimizing energy consumption by

shutting down non critical loads.

• Auto and Manual options are available for user to

select predefined loads.

• Trip status of the incomer will be monitored real

time basis for tripping non critical loads

Load Shedding

Low PF Indication

Alerts - Email / SMS

• Reports like Hourly, Shift energy can be sent via Email

• SMS facility to the mobile for Hourly & Daily Energy, MD alerts

• Email and SMS can sent during abnormal conditions

• Customized Email/SMS alert options.

ELNet Server

Alerts

Customized Features 1

Specific Energy Consumption

Energy Consumed per unit of product, to analyze production cost

• Reports Energy Cost per yield

• SEC determines total cost of the production

• Process wise energy consumption Reports

• Indicates efficiency of the human Vs Machinery

Customized Features

Customized Features 2

Plant Load Factor

A measure of Plant capacity utilization

• Provides Plant efficiency

• Power generation capability of various units

• Power imported from and exported to Grid

Single Line Diagram

Schematic network visualization to monitor, manage the electrical distribution network

• Equipment Status Monitoring

• Incorporates critical equipment parameter details (UPS, battery, generator, power distribution etc)

• Provision for user configurable preset alerts

Customized Features

Our Solution Helps ….

Top ManagementVP/CEO

IT PersonnelCommercial

ManagerFacility

ManagerPlant / O&M

Manager

Trade Supporter

Operators TechniciansShift

Persons

• Dash Board• Alarms• SEC

• Monthly / Yearly Energy Report

• TOD Report• MD Report• Avg PF Report

• Online Monitoring• Alarms• Hourly / Daily /

Shift Energy Reports

Lighting Management System• Power consumption by lighting varies between 20 - 25% of the

total power.• Occupants have a little insight over their building environment.• The inability to control brightness is usually a big factor in energy

wastage.

Tunable Light

Benefits of Wireless Lighting ManagementTunable Light

Regulate how bright your lights are.

Set maximum light levels.

Customizable as per the tasks and the general ambience of your office.

Daylight Harvesting

Occupancy Monitoring

Smart Scheduling

Personal Software Control

Daylight Harvesting

Automatic dimming/switching lights in response to the available day light.

Adjusts indoor light levels according to natural light.

Minimum light level. Ensures emergency lights ON. Non-critical lights OFF.

Turning ON the lights in response to the room occupancy.

Highly sensitive occupancy sensors detect even the small movements.

If the room is unoccupied, lights turn off automatically.

Occupancy Monitoring

Smart Scheduling

Schedule when the lights should turn on and off in any part of the building.

All timings can be controlled straight from the dashboard.

Comes in handy when rooms need lighting despite their occupancy.

Personal Software Control

Turning ON/OFF the lighting loads right from the PC.

Setting of level of light, right from the dashboard.

Energy Costs vs Energy Savings

100%

80%

60%

40%

20%

EnergyCosts

EnergySavings

When energy losses are brought down,

Your Savings moves up!

Street Light Management System

Components Used:• Lighting Control Units (LCUs) fitted to light modules,

connected to controller over zigbee networks.• GPRS Gateway collects information from LCUs and

sends to cloud based server over internet.• Web based application in the cloud provides

monitoring, control and analytics of light modules.

Architectural Model

Advantages:• Dimming of lights

increases the life time.• Mitigating energy

costs.

Features:• Light Intensity (LUX)

based control.• Time scheduling.

Service Provider

ServerGATEWAY

GP

RS

Street Lights

Wastage of water not only leads to inefficient usage but also increases energy bill

Water Management System

• Allows to track, monitor and control the water usage.

• Improved accuracy for billing as well as enhanced cash flow.

• Increased revenue by reducing leaks and water that is unaccounted.

• Ease of conducting preventive maintenance through detailed reporting and

analysis.

• Figure out specific timings for water usage and demand.

• Better ROI

Wireless Water Management SystemMonitor and Control

• Allows to measure, monitor and to control the water flow using Flow Control valve.

• Flow Control valve regulates or cut ON/OFF the water flow thereby reducing wastage.

Monitor and Control with Level & Pump Automation• Water level at overhead tank and sump can be measured by sensor

which switches ON/OFF the pump automatically.• Controlling pump operation avoids overflow from tank and dry

running of pump.

Building Energy Management System - Features

Intelligent savings calculator to keep a track of how much you’re saving of the bill.

Multi-platform dashboard to monitor and regulate electrical loads from PC, tablet or mobile phone.

Data storage and Event based Reports

Regulation of energy consumption in the workspaces by scheduling according to their preferences

Analytics for energy consumption

Regular reports via SMS and email.

• Industries

• Hospitals

• Ships

• Residential complex

• Malls

• Multiplex

• Office buildings

• Hotels etc.

Applications

Static Watt Hour MeterPRE-PAID | POST-PAID | THREE PHASE | SINGLE PHASE | DUAL SOURCE

• User friendly, compact wall mounting design• Dual source measurements upto 80A whole current / CT

operated• Currency based recharging for EB, DG, Gas and Water (Upto 4)• No separate EB and DG re-charging• Displays and communicates balance, VLL, VLN, A, F, W, PF, VA,

kWh/kVAh (EB and DG), Gas and Water input pulse.• Tripping of EB or DG consumption at pre-determined set point

for protection and effective use of energy• Current limiting facility for DG/EB separately• History of recharge• Protects equipment against overload/over voltage• Selection of DG power either 3 phase or single phase

programmable at site – replaces ACCL and Minimize wiring complexity

• Over voltage protection at 285V default (programmable at site)• Display blinks in the frequent interval to indicate low balance

Single Phase

Three Phase

Prepaid Metering

Multiple Options• Prepaid –Electricity, Gas

and Water • with RF card• with RS 485• with Zigbee• with GSM/GPRS• Combination of RS

485 and with GSM/GPRS

• Prepaid / post paid

e-Prepaid Metering – GSM/GPRS

Prepaid Meter – ElSoft PPS

Com. Settings / Cost input

Add / Edit / View customer information

RF Card or RS485 or GSM/GPRS modem

FlexibleIntelligent Recharge with

Reports

Create

Grid/ DG / Water / Gas – Configuration of Tariff and Tax %

Prepaid Meter – ElSoft PPS

Add / Edit / View customer information

Prepaid Meter – ElSoft PPS

Reports

Prepaid Meter – ElSoft PPS

Prepaid Meter – ElSoft PPS through RS485

Benefit to the consumers ElSoft – Mobile APPS• Remote switch ON/OFF through Mobile app

• User can get sms on Overload, over voltage etc.

Prepaid Meter - Manufacturing

• Fully automated Calibration

• Multiple level calibration

• Prepaid solution for Electricity, Gas and water

• Up to 80A rating

Demand ControllerUser Friendly I Dynamic Communication I Load Manager

• Programmable Sliding or Block window• Programmable VA or W or Amps Average Demand • Programmable Demand period 5 – 30 mts

15 second Integration• Programmable Demand control

Forecast Step

• Viewing Present , Forecast, Max Demand andAdditional load on same page

• Compact 96x96x45mm• 4 Relay control output• TOD

Energy 6 Slots Maximum Demand 4 slots

Energy above demand can be monitored

Load ManagerUser Friendly I Cost Effective I Field Programmable

• Multi Parameter Digital Display Meters…..• LG Series to read VAF, Power and Energy parameters.

Features:

• 4 Digit 3 row or 6 digits single row display with ease of navigating / programming.

• Auto scrolling in some models.• 4 digits, 3 rows display avoids scrolling through many pages.• Can be linked to EMS.• Old Register to store earlier energy reading.

Dual Source Energy MeterUser Friendly I Cost Effective I Field Programmable

• Both Energy Source can be viewed simultaneously for Wh and VAh

• Separate Load hours for EB – DG.• OLD Energy register • 8 digit Resolution.• Also available in Load Manager• Programmable Trigger can be set for VLL, A, Hz, W, VA and PF• Compressor study, Load fluctuation

Power & Energy MeterUser Friendly I Cost Effective I Field Programmable

• 4 Digit 3 row or 6 digits single row display with ease of navigation / programming.

• Auto scrolling Option• Forward Energy Accumulation• Reverse Lock Option• 4 digits, 3 rows display avoids scrolling through many pages.• Can be communicated to EMS.• OLD Register to store previous energy reading.

Application Pack

Digital Input• For Cost Effective Low Profile

Networking• Acts as Mini Concentrator• For Productivity Study• For Production Flow Monitoring

Digital Output• Programmable 4 Relay outputs

V, A, Hz, Under/ Over W, VA, PF, Energy, Single Phase prevention, Reverse

Current• Programmable trip time

(1 to 180 Seconds)• Typical Applications

Protection of Equipments from Abnormal Conditions

Auto Connection or Disconnection of Alternate Power Source

Application Pack

Analog Input• Two Analog Input

• 0-20mA, 4 to 20mA or 0 to 1V Programmable to any full scale and offset

Typical Application • Process parameters like Temp,

Oil level, Pressure, Flow, rpm etc. can be seen and integrated

• These data can be polled to ELNet software or any third party software

RS 485 to RS 232Converter

Process module with0 to 20mA or 4 to 20mA

Process module with0 to 20mA or 4 to 20mA

Channel 1

Channel 2

Smart Basic MeterCost Effective I User Friendly I Field Programmable

• Four digit resolution with auto scaling.• Field programmable Star (Wye) or Delta or single phase configuration.• Average & phase wise information.• Optional direct measurement up to 20A. 60A or 100A max. using

Hanging CT.• Universal auxiliary input 80 - 300V AC (Optional: 40-300V DC, 80-300V

AC/DC).• Auto-scrolling.• 2 digital output programmable for threshold up to 6 parameters

(Under/Over).• Analog transducer output 0-20mA / 4-20mA or 0-1V, Accuracy of 1% FS.

Earth Leakage RelayCost Effective I User Friendly I Field Programmable

• Microcontroller based design• Peak Detection and Value Display• Password Protection• Current Sensitivity Range 300mA – 12A• Programmable Trip Time 300ms -30 seconds• Selection thru Soft keys (No DIP Switches)• Continuous Earth Leakage Display (Programmable)• Intelligent Tripping based on T ¥ 1/A• Auto Scrolling of Trip Info. & Peak Load Current

Power Factor ControllerMultifunction Meter I User Friendly I Three Phase Sensing

• Three phase sensing.• 6 or 8 or 12 switching relay outputs.• Automatic or manual control (manual control with power

backup option).• Fault detection (Over compensation, Under

compensation, Over voltage, Over current, Under voltage, Under current, Over harmonics for voltage and current).

• Displays VLL, VLN, Amps (Average and phase wise) Frequency, W, PF, VAR(Total and Phase wise) Wh, PF Avg.

• Four quadrant operation.• RS 485 communication interface (Optional).

Generator Monitoring Unit (Gen Duos)Cost Effective I User Friendly I Field Programmable

• Monitors 5 key electrical parameters of the genset.• Dual display - eliminating the use of multiple meters. • Reduces cost and simplifies panel wiring.• Ideal solution for generators.• Simultaneous display of kWh and V or A or Hz.• One common CT,PT settings for all parameters.• Programmable for single phase & three phase

applications.

AC & DC Power Analyzer (Power Duos)Reliable I Compact I Economical Solution

• Cost effective single solution for AC & DC application.• Ideal for Solar, data centers, UPS systems etc.• Optional EB/DG energy with load hours.• True RMS measurement.• Accuracy class 1.0 IEC 61036 / CBIP 88 (0.5 option).• Suitable for multiple power generating solutions.• User programmable password protection.

Motor Protection Unit / SystemCost Effective I Compact I Economic Design

• True RMS measurement• Accuracy class 1.0 IEC 61036 / CBIP 88 (0.5 option)• User programmable password protection• Auto-scaling of Kilo, Mega, Giga and decimal point• Auto scrolling• Finger touch proof terminals for voltage and current

connections• Clearance & creepage distance meets UL 61010 safety

standard• Communication with PCs, PLCs, DCS through optional RS

485/232 serial interface• Digital output with programmable trip time for protection• Displays more than 25 parameters Basic (VLL, VLN, A, Hz);

Power (W, VA, PF) and Energy (kW, Load Hours)• Displays the reasons for tripping for future correction• Programmable start time from sensing safe condition

Motor Protection System

Motor Protection System

Multi-channel Load ManagerBranch Monitoring Circuit I Cost Saving I Compact Design

• Multi-channel data collection• Displays Basic, Power and Energy parameters• Optional Zigbee Communication (Default RS 485)• Space saving compact design for easy installation into

existing panel boards• True RMS measurements• Simultaneous sampling of Volts & Amps• Accuracy class 1.0 IEC 61036 / CBIP 88 (0.5 option)• User programmable password protection• Energy resetting @ 999999 kVAh × Multiplication factor

Others ….

Telecom, Media Industry

Hospitals, Automobiles

OEM, Steel Plant

Solar Applications

Pharmaceuticals

National References

Sugar

Commercial Complex

Research

Educational

Textiles

Cement

Power Plant

Tyres

Electronic

Case Studies

Amaravathi TextilesInvestment – 10 LakhsPayback Period – 4 Months

Life Style International Pvt. Ltd.Investment – 2.4 LakhsPayback Period – 5 Months

Dr. Reddy’s LabInvestment – 0.25 MillionPayback Period – 5.4 Months

Splendid TowersInvestment - INR 2.12 LacsPayback Period - 6 months

Hetero Drugs Ltd.Investment - INR 2.5 LacsPayback Period - 6 months

Return On Investment

Company Name Investment in INR in Lakhs Pay back Period in Months

Dr. Reddy’s Lab 2.5 5

C.R Mills 0.32 < 1

Amaravathi Textiles 10 4

G.K.N.M Hospital 2.15 9

Granuals India 2.14 7

Hetero Drugs 2.5 6

Splendid Towers 2.12 6

Life Style 2.4 5

ElMeasure TM worldwide

Giving back to society through theElMeasureTM CSR Program

schools

colleges

orphanages

hospitals

Take the ElMeasureTM Site Survey today.

Learn more about the ElMeasureTM range ofEnergy Management Solutions and Services.