Eaton Power Distribution Rack PowerChain Management solutions Features Flexible power distribution with up to 168 factory-installed branch breakers in a highly compact footprint Designed for high-density racks, with 400A panels and high power inputs Aesthetically pleasing design, with an elegant rack enclosure in textured black finish Free-standing unit with top and bottom cable entry for fast, flexible installation Front and/or rear access, column power panels, large LCD for ease of servicing Extensive monitoring options, including the Eaton ® Energy Management System Optional branch circuit monitoring to manage and monitor power down to individual circuits Detailed event and trend information to support capacity planning and avoid unexpected breaker tripping Factory-configured and tested to ensure highest reliability Flexible, high-density power distribution for rack environments Product snapshot Up to 168 circuits in a single enclosure Four 400A (225A) circuit panels (two front and two rear) EIA standard enclosure Eaton Energy Management System (EMS) Main lug or main breaker configuration Are you looking for a space- saving way to distribute power throughout your data center? Are dual- and triple-corded loads stressing your available supply of pole positions? Do you want to minimize reliance on licensed electricians as you make moves, adds and changes? Would you like to resolve these issues without installing clunky power distribution equipment in your sleek, modern rack line- up? If the answer to these ques- tions is yes, Eaton has the solu- tion for you with the new Eaton Power Distribution Rack (PDR). The PDR was designed for the realities of modern data centers—floor space is costly, change is inevitable, and uptime is critical. The PDR was also designed for a more intangible reality: aesthetics. The uniform, elegant look of your data center con- veys an impression of order and professionalism. New equipment acquisitions should enhance that appearance, not clutter or detract from it. Big power in a small footprint with a sleek look The PDR offers up to 168 cir- cuits in an elegant, textured black enclosure that harmonizes with the rest of your data center line-up. For flexible power distribution, place the PDR in the middle of a row or at the end of the row. Either way, you will minimize cable runs and use floor space wisely. Traditional power pan- els were a compromise in this regard. Not matching the depth of the rest of the enclosures, they left valuable floor space idle. Now you can accommodate all those new servers with their multiple power cords… all those rack power distribution units that feed growing loads… simply by using a high-density PDR that stands on minimal floor space and enhances the elegance, practicality and reliability of your data center.
Transcript
Page 1: PowerChain Management solutions Eaton Power Distribution Rack€¦ · Eaton Power Distribution Rack PowerChain Management solutions Features • Flexible power distribution with up

Eaton Power Distribution Rack PowerChain Management solutions

Features• Flexiblepowerdistributionwithupto168factory-installedbranch

breakersinahighlycompactfootprint

• Designedforhigh-densityracks,with400Apanelsandhigh powerinputs

• Aestheticallypleasingdesign,withanelegantrackenclosureintexturedblackfinish

• Free-standingunitwithtopandbottomcableentryforfast, flexibleinstallation

• Frontand/orrearaccess,columnpowerpanels,largeLCDfor easeofservicing

• Extensivemonitoringoptions,includingtheEaton®EnergyManagementSystem

• Optionalbranchcircuitmonitoringtomanageandmonitorpowerdowntoindividualcircuits

• Detailedeventandtrendinformationtosupportcapacityplanningandavoidunexpectedbreakertripping

• Factory-configuredandtestedtoensurehighestreliability

Flexible,high-densitypowerdistributionforrackenvironments

Product snapshot

Up to 168 circuits in a single enclosure

Four 400A (225A) circuit panels (two front and two rear)

EIA standard enclosure

Eaton Energy Management System (EMS)

Main lug or main breaker configuration

Areyoulookingforaspace-savingwaytodistributepowerthroughoutyourdatacenter?Aredual-andtriple-cordedloadsstressingyouravailablesupplyofpolepositions?Doyouwanttominimizerelianceonlicensedelectriciansasyoumakemoves,addsandchanges?Wouldyouliketoresolvetheseissueswithoutinstallingclunkypowerdistributionequipmentinyoursleek,modernrackline-up?

Iftheanswertotheseques-tionsisyes,Eatonhasthesolu-tionforyouwiththenewEaton Power Distribution Rack (PDR).ThePDRwasdesignedfortherealitiesofmoderndatacenters—floorspaceiscostly,changeisinevitable,anduptimeiscritical.

ThePDRwasalsodesignedforamoreintangiblereality:aesthetics.Theuniform,elegantlookofyourdatacentercon-veysanimpressionoforderandprofessionalism.Newequipmentacquisitionsshouldenhancethatappearance,notclutterordetractfromit.

Big power in a small footprint with a sleek lookThePDRoffersupto168cir-cuitsinanelegant,texturedblackenclosurethatharmonizeswiththerestofyourdatacenterline-up.

Forflexiblepowerdistribution,placethePDRinthemiddleofaroworattheendoftherow.Eitherway,youwillminimizecablerunsandusefloorspacewisely.Traditionalpowerpan-elswereacompromiseinthisregard.Notmatchingthedepthoftherestoftheenclosures,theyleftvaluablefloorspaceidle.

Nowyoucanaccommodateallthosenewserverswiththeirmultiplepowercords…allthoserackpowerdistributionunitsthatfeedgrowingloads…simplybyusingahigh-densityPDRthatstandsonminimalfloorspaceandenhancestheelegance,practicalityandreliabilityofyourdatacenter.

Page 2: PowerChain Management solutions Eaton Power Distribution Rack€¦ · Eaton Power Distribution Rack PowerChain Management solutions Features • Flexible power distribution with up

2 EATON CORPORATION Eaton Power Distribution Rack

Designed for the adaptable data centerMeet ever-increasing power demands.Someotherrackpowerpanelsonthemarketaredesignedwithmorecircuitsthanthemainbreakercanaccommodate:42polepositionsonapanelratedfor225A.Inthisconfiguration,someofthecircuitsareuseless—orifusedtocapacity,couldeasilytripthemainbreakerandjeopar-dizeyourcriticalload.

ThePDRusesoptionalhigher-capacity400Apanels,soyoucanmakefulluseofallcircuits.Theunitcanbeconfiguredwithonetofourofthesepowerpanels.Branchcircuitsarearrangedinacolumnforsuperiorwiringdesign.Spaciouswirewaysoffermoreroomtoworkforfastandeasyinstallationorchanges.Alargeairspacebeneaththepowerpanelspermitsimprovedaircirculationandmakesiteasyfortechnicianstomanagecabling.

Straightforward installation.ThestandalonePDRisfullyconfig-uredandtestedatthefactory,soinstallationissimple.Withyourchoiceoftoporbottomcableentry—aswellasfrontand/orrearpowerpanels—itiseasytoretrofitintoanyexistingdistribution system.

Flexible design.Mostotherrackpowerpanelshavetobeconfig-uredforeithertoporbottomcableentryatthefactory—andsomedon’toffertopcableentryatall.ThePDRcanbeconfiguredforeitheroption,makingitappropriateforraised-floorornon-raised-floorapplications.

Monitoring for premium availabilityContinuous insight into power conditions.PDRsareequippedwiththeEMS.Withthisstate-of-the-artmonitoringandalarm system,youcan:

• Monitorpowerconsumptionandensurepowerquality.

• Manageandplanpowerneedsindynamicenvironments.

• Reactquicklytopotentialproblemsdowntothebranchcircuitlevel.

OptionalbranchcircuitmonitoringwithintheEMScontinuouslymeasuresthecurrentonbranchcircuitsandwarnsofimpendingtrouble,soyoucantakeproactivesteps.Thesystemassessescir-cuitactivity7x24andprovidestime-stampedmetering,alarmandstatisticalinformationforeachbranchcircuit.

Armedwiththeseinsights,datacenterandfacilitiesmanagerscanmoreeffectivelymanageenergyconsumptiontopreventoverloadconditions,optimizepowerdistributionand,whereapplicable,accuratelybillinternalcustomersforpowerusage.

Monitoring and management from anywhere.WiththeoptionalPowerXpert®Gateway1000interfacecard,thePDRcansecurelytransmitreal-timestatustoremotemonitoringstations,admin-istratorPCsorwirelessdevicesanywherewithinthereachofanetworkconnection.Remotepersonnelcanconfigure,monitorandmanagethesystemfromanywhereoverthecompanynetworkorthe Internet.

Panelboard breakers can be the tradition-al 225A or 400A.

400A breakers enable you to make full use of all 42 pole positions on a panelboard.

Top and bottom cable entry opens up many choices for installation.

Monitor and manage the PDR over the network with the optional Power Xpert Gateway 1000 card.

Design for quality, security and convenience• Freestandingstructurewithtopandbottomcableentry

opensupmanychoicesforinstallation.

• Industry-standardfootprintmakeseffectiveuseofvaluabledatacenterspace.

• Attractive,texturedblackfinishmatchesyourequipmentandprovidesamodernlook.

• Spaciouswireways,hingeddoorsandremovablesidepan-elsenableeasyserviceaccess.

• Lockingdoorlatchesprotectthepowerdistributionsystemfromunauthorizedaccess.

• OptionalPlexiglascoverpanelsprovideeasyvisibilityto breakers.

• X-Slotbayssupportmanycommunicationoptionsforremotemonitoringandmanagement.

• Large,brightLCDwitheasy-to-usemenusupportslocalmoni-toringandconfiguration.

• Loadprofilelogshowspowerconsumptiontrendsforupto24months;historylogshowsupto128time-anddate-stampedevents.

Page 3: PowerChain Management solutions Eaton Power Distribution Rack€¦ · Eaton Power Distribution Rack PowerChain Management solutions Features • Flexible power distribution with up

3 www.eaton.com/powerquality 1.800.356.5794

Current and historical insights close at hand.Locally, technicianshaveanat-a-glanceviewofsystemstatusonalarge,8-linex40-characterLCD.Unitswithfrontandrearpanelshave twodisplays.

Amenuwithsoftkeysmakesiteasytonavigatethroughthefea-tures.Audio/visualindicatorsprovidealarmsandstatusupdates.Throughthislocaldisplay,youcanviewpowerconsumptiontrendsinahistorylogforupto24months—apowerfulaidincapacityplanning.Customalarmsettingscanbeprogrammedatthefactory,bytheuserorbyEaton’sserviceorganization.

Optional surge suppressionEvenwithintherelativesafetyofyourdatacenter,powersystems(andtheequipmentconnectedtothem)couldbeaffectedbylightningstrikesandothertransientaberrationsinvoltageandcur-rent.Forexample,atransienteventcouldtriggeraUPStoactivateitsstaticbypasspath,leavingcriticalloadsexposedtorawutilitypower.

IfthefacilitydoesnothaveTVSSdevicesattheutilitypointofentry,orifTierIVredundancyisrequired,consideraddingittoyourPDRforanimportantlayerofextraprotection.

Part of a complete data center solutionThePDRispartofafamilyofsolutionsthatareredefiningtheeco-nomicsofrunningthemoderndatacenter.Inadditiontofreestand-ing,wall-mountedandrack-mountedpowerdistributionsystems…

• Energy-efficientUPSsandPDUsdelivermorepowerinless rackspace.

• PatentedparallelingprovidesTierIVredundancy.

• AdvancedbatterytechnologieskeepITsystemsupwhenutilitypowerisdown.

• Rugged,attractiveenclosureshouse,protectandorganizeITandpowerqualitysystems.

• Powermonitoringoptionsgivefullvisibilityintothehealthofthesystem,fromindividualcircuitstotheentirefacility.

Eatondatacentersolutionsenableyoutocreateamoreresilientandadaptabledatacenter—onethatuseslessenergy,runsmoreefficiently,andprotectsyourinvestmentsinapplications,dataandhardware.Findoutmoreatwww.eaton.com/powerquality

A new level of confidenceEatonisagloballeaderinpowerqualityandmanagement solutions—namedbyFrost&Sullivanas“PowerQualityCompanyoftheYear”in2004,2005and2007(August2007).Ourruggedpowerdistributionunitsreflectmorethan40yearsofexpertiseinindustrial-strengthpowerqualitysolutions.Infact,wehavebeenmanufacturingPDUsforseveralothermajorbrandsforyears.

ThePDRdeliversconfidence—confidencethatthepower circuitsservingyourbladeserversandotheressentialequipment areappropriatelyloadedandcapableofsupportingthehigh availabilityyoudemand.Formoreinformation,visitourWebsiteat www.eaton.com/powerquality,orcontactusat1-800-356-5794.

X-Slot® bays support many communication options for remote monitoring and management.

A large, bright LCD with easy-to-use menu supports local monitoring and con-figuration.

The load profile log shows power consumption trends for up to 24 months.

The history log shows up to 128 time- and date-stamped events.

Page 4: PowerChain Management solutions Eaton Power Distribution Rack€¦ · Eaton Power Distribution Rack PowerChain Management solutions Features • Flexible power distribution with up

Technical specifications Electrical input

Nominalvoltage 208Y/120VacNominal 50/60Hz(45–65Hz) frequency(range)Inputconductor Three-wire+neutral+ground configuration Input connection options

Directconnectiontopanelboardmainbreakers(225A,400A)Connectionintosingleordualmainlugs(800A)Connectionintosingleordualmainbreakers(400A,600A)—sideaccessrequired Connectivity

OptionalPowerXpertGateway1000communicationscardBuilt-inWebandSMTPserverSupportforModbusTCP,SNMPandNTPprotocolsTwo(2)isolatedRJ-45Ethernetportsforredundancy Monitoring

Standardsystem-levelmonitoringNon-volatilereal-timeclock

Meters and load profiling points: Input1V12min/max Input1V23min/max Input1V31min/max Input1ACUVtotaltime Input1I1min/max(with optionalMainCTsinstalled) Input1I2min/max(with optionalMainCTsinstalled) Input1I3min/max(with optionalMainCTsinstalled) Input1V12THDmax Input1V23THDmax Input1V31THDmax Input1frequencymin/max Input1kVAmin/max(with optionalMainCTsinstalled) Input1powerfactormin/max(with optionalMainCTsinstalled) Input2V12min/max Input2V23min/max Input2V31min/max Input2ACUVtotaltime Input2I1min/max(with optionalMainCTsinstalled) Input2I2min/max(with optionalMainCTsinstalled) Input2I3min/max(with optionalMainCTsinstalled) Input2V12THDmax Input2V23THDmax Input2V31THDmax Input2frequencymin/max Input2kVAmin/max(with optionalMainCTsinstalled) Input2powerfactormin/max(with optionalMainCTsinstalled) GNDImin/max NEUImin/max

PowerXpertGateway1000Cardfirmwareisuser-upgradeable

Premium Eaton Branch Circuit Monitoring System (BCMS)

Individual panel monitoring

Configurable parameters: Panelnumber Panel name Nominalinputvoltage Nominalinputfrequency SystemkVA CTspresent L-LorL-Ninputsetting Main CT ratios Calibrationofinput,output, groundandneutralCTs Calibrationofvoltage Breakerrating Breakerwarninglevel Breakertype

Main panel board metering alarms Panelorsubfeedbreakeroverloadwarning Panelorsubfeedbreakeroverloadalarm Panelbreakeroverloadwarning Panelbreakeroverloadalarm Breakercurrentwarning Breakercurrentoverload

Branch circuit or subfeed breaker monitoring—up to 42 per panel (User can easily add panel breakers)

Configurable parameters —individual branch circuits Breakerrating Breakerwarninglevel Breakeroverloadlevel Breakertype

Individual branch circuit alarms (for each breaker): Breakercurrentwarning Breakercurrentoverload Distribution panelboards

42-circuitcolumn–ratedfor225A–maximumtwo(2)perside42-circuitcolumn–ratedfor400A–maximumtwo(2)perside Options

Transientvoltagesurgesuppression(TVSS)50kA/phor100kA/phIsolatedgroundBranchcircuitmonitoringPlexiglasormeshdoors Environmental and safety

Operating 0ºCto40ºC(32ºFto104ºF) temperatureRelativehumidity 5–95percentnon-condensingAudiblenoise <45dBAmeasured1.5m(5ft.)fromunitunder normaloperatingconditionsEMI FCC47,part15forClassAdevicesAgencymarking Domestic/Canadianmodels:UL/CSA60950-1 Physical characteristics

DimensionsHxWxD,in(mm)78.5x23.5x38(1994x597x965)ApproximateProductWeight,lb(kg) Oneside450(200) Twosides700(315)

Event logging: Input1ACovervoltage Input1ACundervoltage Input1underoroverfrequency Input2ACovervoltage Input2ACundervoltage Input2underoroverfrequency Buildingalarm1 Buildingalarm2 Buildingalarm3 Buildingalarm4 Input1overload(4levelsper phase,withoptionalMainCTs installed) Input2overload(4levelsper phase,withoptionalMainCTs installed) Input1phaserotationerror Input2phaserotationerror Configurationerror Alarm,highinput1THD (per-phasealarm),currentor voltage Alarm,highinput2THD (per-phasealarm),current orvoltage Alarm,neutraloverloadwarning (perpanel) Neutraloverload(perpanel) Groundcurrentwarning(perpanel) Groundcurrentoverload (perpanel)

Monitored parameters: RMS:V1,V2,V3,I1,I2,I3 Average:Vavg,kW,kVA,PF Load:MonthlykWh,yearlykWh, totalkWh Percentage:Input1,Input2, Input3,Inputtotal(percentload) Max:Vmax,Imax

Eaton, Flex, LanSafe, PowerChain Management and PowerTrust are trade names, trademarks, and/or service marks of Eaton Corporation or its subsidiaries and affiliates. All other trademarks are the property of their respective owners.

Monitored parameters Current:RMSandpercentage Average:kW,kVA,PF Load:MonthlykWh,yearlykWh, totalkWh Max:Amperage,kW Min:Powerfactor

UNITED STATES 8609 Six Forks Road Raleigh, NC 27615 U.S.A. Toll Free: 1.800.356.5794 www.eaton.com/powerquality

CANADAOntario: 416.798.0112 Toll free: 1.800.461.9166

LATIN AMERICASouth Cone: 54.11.4124.4000 Brazil: 55.11.3616.8500Andean & Caribbean: 1.949.452.9610Mexico & Central America: 52.55.9000.5252

EUROPE/MIDDLE EAST/AFRICADenmark: 45.3686.7910 Finland: 358.94.52.661 France: 33.1.6012.7400 Germany: 49.0.7841.604.0 Italy: 39.02.66.04.05.40 Norway: 47.23.03.65.50Portugal: 55.11.3616.8500 Sweden: 46.8.598.940.00 United Kingdom: 44.1753.608.700

ASIA PACIFICAustralia: 61.2.9693.9366New Zealand: 64.0.3.343.3314China: 86.21.6361.5599HK/Korea/Taiwan: 852.2745.6682India: 91.11.4223.2300Singapore/SEA: 65.6825.1668

©2010 Eaton CorporationAll Rights ReservedPrinted in USAPDRFXAJanuary 2010


Recommended