N50·N100·N300·N500·N5000 Series
POWERFUL OPERATION & HIGH PERFORMANCE
Hyundai N-Series inverters with characteristics of digital control
and open network communication are newly developed products.
The compact Hyundai N-Series inverters, produced by the
state-of-the-art equipment, cover micro to high voltage large
capacity. They are new generation products meeting the
customers’ needs.
Hyundai Heavy Industries realizes thesatisfaction of customer with its bestproducts.
HYUNDAI
N50 Series 06
N100 Series 08
N300 Series 10
N300-P Series 12
N500 Series 14
N5000 Series 16
C o n t e n t s
EconomicalEfficiency
HighReliability
Convenience
Suppleness
HighFunction
Versatility
We build a better future!
H Y U N D A I I N V E R T E R h i R U N N - S e r i e sH Y U N D A I I N V E R T E R h i R U N N - S e r i e s
N500
N300
N100
N50
N5000
HHI will realize customer satisfaction with its new
hiRUN N-Series04
Features
Fan, Pump, Conveyor,Wood working machine
Conveyor, Treadmill,Washing machine,Waste heat recoveryequipment, Automaticdoor, Extruder
1Ø200V : 0.4 ~ 1.5kW
3Ø200V : 0.4 ~ 7.5kW
3Ø400V : 0.4 ~ 7.5kW
1Ø220V : 0.75 ~ 2.2kW
3Ø200V : 5.5 ~ 55kW
3Ø400V : 5.5 ~ 132kW
3Ø200V : 5.5 ~ 75kW
3Ø400V : 5.5 ~ 160kW
3Ø400V : 160 ~ 350kW
3Ø400V : 200 ~ 380kW
3Ø3.3kV : 450 ~ 1500kW
3Ø6.6kV : 900 ~ 3000kW
N300
(High Performance
Vector)
N300-P
(Fan, Pump)
N500
(Medium, Large
Capacity Vector)
N500-P
(Medium, Large
Capacity)
N5000
(High Voltage Large
Capacity Vector
Voltage Type)
N100
(Small Vector)
N50
(Single Phase
Vector)
•High torque with sensorless vectorcontrol•MMI using RS485•Auto tuning•Compact size
•Compact size•High starting torque•Various operation methods•Easy maintenance
•Compact size•Powerful operation with improved
sensorless vector technology•Multi motor operation
•Automatic energy saving•Easy maintenance•User friendly interface•Low noised circuit
•Convenient operator(LCD)•Compact size•Trip tracting data save
•Energy saving
•Compact size
•Trip tracting data save
•High effiency•Low total harmonic distortion•Easy maintenance•Limitless distance between motor
and inverter•One touch screen digital operator •Easy to use
Hoist, Crane, Extpuder,Machine tool, Parkingmachine, Textilemachine
Fan, Pump, Blower
Fan, Pump, BlowerN5000
N500
Fan, Pump, Conveyor
Fan, Pump, Blower
N300
N100
As general manufacturer of inverter in Korea, HHI will solve the customers’ problems easily with
its inverter varying from 0.4kW to 300kW
Series Model Capacity Application
N50
Standard Standard
Standard Fan, Pump
Standard
05HYUNDAI INVERTER
Small SizeInverter
MediumCapacityInverter
LargeCapacityInverter
Features
∷Vector inverter for single phasing input only
- High torque of 200% or greater at speeds as low as 1 Hz during starting
and operation.
∷Realize triples driving by adding current suppression
- Stable operation even under the instantaneous impact load and overload
is realized through the addition of over-current level adjusting function.
- Maintain constant speed even at the time of sudden load change by rapid
speed restoration characteristics.
- Applicable to the transfer machine, treadmill, industrial washing machine
due to its function of momentary current suppression.
∷Possible to select various operation method
- It is possible to select the operation method of either RS485
communication driving or analog signal driving for the user’s convenience.
∷Compact size for easy installation
- Reduction in cubic volume, 52% compare to the N100 series.
∷Develop optional product for user convenience
- DOP05 : Economical remote operator, Operation & display function
Series
PK
Series
hiRUN N-Series
[ Single Phase Vector Inverter ]
06
RL1
T1U
T2V
T3W
TL2
P
RB
Power supply
Inverter
Motor
RS485Communication
AnalogSignal
07HYUNDAI INVERTER
h i R U N N - S e r i e s
Standard Specification
Model
Applicable motor capacity (kW)
Rated output current (A)
Rated output capacity (kVA)
Rated output voltage (V)
Maximum output frequency (Hz)
Voltage / frequency
Power conditions
PWM method
Control method
Output frequency range
V/F characteristics
Overload rating
Starting torque
Torque boost
Acceleration/deceleration time setting
Acceleration/deceleration pattern
Current stall prevention operation level
Voltage stall prevention operation level
Analog frequency setting
Protective functions
Ambient temperature
Ambient humidity
Storage temperature
Installation area
Altitude and vibration
Cooling method
International directive compliance
N50-007SF
0.75
5.0
1.9
3-phase, 200~230 V
400 Hz
Single phase, 200~230Vac, 50/60 Hz
Voltage: ±10% / frequency: ±5%
Space vector PWM
V/F control, sensorless vector control
0.1 ~ 400 Hz
V/F free-setting (30~400 Hz of base frequency), constant torque and reduced
torque patten selectable
150% of rated current for 1 minute
More than 200% (at 1 Hz)
Manual torque boost can be set between 0~50%
0.1~3000 sec
Linear, S-curve, U-curve
Operating current level setting possible (20~200%), enable/disable selection
Operating current level constant, enable/disable selection
DC 0~10 V / 4~20 mA
Over current protection, under-voltage error, output short circuit, overland shut-off
(electronic thermal), ground fault, extermal trip, communition error, EEPROM error
-10~40 (no freezing)
90% RH or less (non-condensing)
-20~60 (short-term temperature during transport)
Indoors without corrosive gases, flammable gases, oil mist or dust
Maximum 1000m or less above sea level, 5.9 m/s2 or less
Forced cooling
CE & UL/cUL
N50-015SF
1.5
7.0
3.0
N50-022SF
2.2
11.0
4.2
Out
put
Inpu
tC
ontr
ol c
hara
cter
istic
Envi
ronm
ent
Dimension
RUN
FUNC
W
STR
STOP
POWER
A Hz
RUN PRG
RESET
MIN MAX
경고WARNING
D
H
N50 Series Type
Motor (kW)
Single-phase 200 V
0.75 1.5 2.2
Model W D H
007SF
015SF, 022SF
80
95
Unit : mm
142
142
135
135
Features
PK
Series
hiRUN N-Series
Series
∷Advance sensorless vector control function- Realize smooth driving without motor vibration and high precise driving with
no effect of changing load.
- Show high torque of 200% or greater at speeds as low as 0.5Hz during
starting and operation.
∷Strengthening auto-tuning function- Automatically measure motor parameters.
- Realize optimal motor control without torque dropping and speed fluctuation.
- Realize precise driving without inconvenience of user and measure motor
parameters manually.
∷Strengthening the PID control function- Strengthening the speed control program for controlling flux, temperature,
pressure and so forth.
- Apply to high precision systems by high speed responsibility.
∷Realize tripless driving by adding current suppression- Realize stable driving at instant impact load and overload by adding
over-current level adjusting function.
- Maintain constant speed on changing load suddenly by rapidity speed
restoration characteristics.
- Widely apply transfer machine, treadmill, industrial washing machine and so
forth by momentary current suppressing.
∷MMI function using RS485 communication (HIMS 2000)- Built-in RS485 communication standard using Modbus protocol possible
flexible application for various FA system, on remote driving at upper system
and easy monitoring the status of driving.
- Realize remote motor control drive using exclusive MMI program.
08
[ Small Size Vector Inverter ]
Dimension
N100 Series Type
Standard Specification
Motor (kW)
Single-phase 200 V
3-phase 200 V
3-phase 400 V
0.4 0.75 1.5 2.2 3.7 5.5 7.5
Option
•Remote Operator : NOP1 (Copy Unit) / DOP1 (Economic)- Cable : 1.5m(Nop1-1A)/3.0m(Nop1-3A)
•Noise Filter - HNF 2020 (200V, 20A) - HNF 4012 (400V, 12A)
W
H
D
h i R U N N - S e r i e s
∷SINK/SOURCE type signal selectable- Many types of programmable controllers are easily connected.
∷Global products- Observe EN standard by attaching EMC filter (option)- Obtain CE Standard, UL, cUL
∷Compact size for easy to install- Reduction in cubic volume 52% compare to the J100 series.
∷Develop option product for user convenience- Digital Operator(operation and display)- Remote Operator(read and copy function)- EMI/EMC filter by EN standard
09HYUNDAI INVERTER
Model W D H
N100-004SF/LF, 007SF/LF, 004HF
N100-015SF/LF, 022LF, 007HF, 015HF
N100-037LF, 022HF, 037HF
N100-055LF/HF, 075LF/HF
N100-037HFK1.2/055HFK1.2/075HFK1.2
115
115
150
185
185
135
155
155
186.5
186.5
130
130
130
250
250
Unit : mm
3-phase, 380 ~ 460 VAC
0.1 ~ 400 Hz
3-phase, 380 ~ 460 VAC
50 / 60 Hz (±5%)
ASIPM
Space vector PWM control
200%, 0.5 Hz
150%, 1 min
DC0~5 V, DC0~10 V, DC4~20 mA, 0~1 kΩ
Model
200 V Class 400 V Class
Applicable motor capacity (kW)
Rated output current (A)
Rated output capacity (kVA)
Rated output voltage (V)
Output frequency range
Input voltage (V)
Frequency
Power transistor
Control method
Starting torque
Overload capacity
Analog input command
Weight (kg)
N100-004SF
0.4
3.0
1.1
1.2 1.2 1.5 1.2 1.2 1.5 1.5 2 5.3 5.3 1.2 1.5 1.5 2 2 5.3 5.3
3-phase, 200 ~ 230 VAC
0.1 ~ 400 Hz
Single-phase 200 ~ 230 V (±10%)
50 / 60 Hz (±5%)
ASIPM
Space vector PWM control
200%, 0.5 Hz
150%, 1 min
DC 0 ~ 5 V, DC 0 ~ 10 V, DC 4 ~ 20 mA, 0 ~ 1 kΩ
3-phase, 200 ~ 230 VAC
3-phase, 200 ~ 230 VAC
N100-007SF
0.75
5.0
1.9
N100-015SF
1.5
7.0
3.0
N100-004LF
0.4
3.0
1.1
N100-007LF
0.75
5.0
1.9
N100-015LF
1.5
7.0
3.0
N100-022LF
2.2
11.0
4.2
N100-037LF
3.7
17.0
6.1
N100-055LF
5.5
24.0
9.1
N100-075LF
7.5
32.0
12.2
N100-004HF
0.4
1.8
1.1
N100-007HF
0.75
3.4
1.9
N100-015HF
1.5
4.8
3.0
N100-022HF
2.2
7.2
4.2
N100-037HF
3.7
9.2
6.1
N100-055HF
5.5
12.0
9.1
N100-075HF
7.5
16.0
12.2Ratedoutput
Ratedinput
PIM PIM
10
Features
Series
PK
N300 Series Type
Motor (kW)
3-phase 200 V
3-phase 400 V
5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132
Series
hiRUN N-Series
[ Powerful Vector Inverter (VFD or AC Drive) ]
∷Powerful operation with advanced sensorless vector control- High starting torque of 200% or greater at 0.5 Hz- High torque of 50% at approximately 0 Hz when the inverter drives a smaller
motor by one frame size
∷Continuous 100% torque within 6~60 Hz for general motor- Unnecessary dedicated motor
∷High torque multi-motor operation- Different motor constants up to 3
∷Minimal rotational fluctuation at low speed- Enhanced process stability and precision
∷On-line / Off-line autotuning
∷On-line auto tuning for motor constant check based on thetemperature
∷Fan On / Off selectable- Fan off during stopping for less noise and longer life
∷Compact size / Easy to maintain- Easy to assemble / Disassembly like cartridge
∷PID Control- Efficient continuous control for winder tension and unnecessary extra PI controller
∷HIMS (Hyundai Inverter Management System) and variouscommunication protocol- DeviceNet, Profibus support (option)- Advanced monitoring funtion
11HYUNDAI INVERTER
h i R U N N - S e r i e s
Standard Specification (200 V Class)
Model
200 V Class
Motor capacity (kW)
Rated current (A)
Rated power (kVA)
Output voltage (V)
Output frequency range
Input voltage (V)
Frequency
Power transistor
Control method
Starting torque
Overload capacity
Analog input command
Weight (kg)
N300-055LF
5.5
24
8.1
3.5 5 5 12 12 12 20 30 30 50
N300-075LF
7.5
32
11
N300-110LF
11
46
15.9
N300-150LF
15
64
22.1
N300-185LF
18.5
76
26.3
N300-220LF
22
95
32.9
N300-300LF
30
121
41.9
N300-370LF
37
145
50.2
N300-450LF
45
182
63
N300-550LF
55
220
76.2
0.1 ~ 400 Hz
3-phase 200 ~ 240 V (±10%)
50 / 60 Hz (±5%)
IGBT
Line to line sine wave PWM
200%, 0.5 Hz
150%, 1 min
DC 0 ~ 10 V, DC -10 ~ +10 V, DC 4~20 mA
3-phase 200 ~ 240 VAC
Dimension
[ A-Type ]
[ B-Type ]
W
H
D
W
H
D
ModelType W D H
A
B
N300-055LF/HF
N300-075~110LF/HF
N300-150~220LF/HF
N300-300LF/HF
N300-370~450LF/HF, 550HF
N300-550LF
N300-750, 900HF
N300-1100, 1320HF
150
210
250
310
390
480
390
480
Unit : mm
140
170
190
195
250
250
270
270
255
260
390
540
550
700
700
740
Option
•Feedback board : N3 - FB•Digital input board : N3 - DG•Communication board (DeviceNet) : N3 - DN•Braking Regenerative Device (BRD Unit)•Input / Output AC Reactor
Ratedoutput
Standard Specification (400 V Class)
Model
400 V Class
Motor capacity (kW)
Rated current (A)
Rated power (kVA)
Output voltage (V)
Output frequency range
Input voltage (V)
Frequency
Power transistor
Control method
Starting torque
Overload capacity
Analog input command
Weight (kg)
N300-055HF
5.5
12
8.3
3.5 5 5 12 12 12 20 30 30 30 60 60 80 80
N300-075HF
7.5
16
11
N300-110HF
11
23
15.9
N300-150HF
15
32
22.1
N300-185HF
18.5
38
26.3
N300-220HF
22
48
33.2
N300-300HF
30
58
40.1
N300-370HF
37
75
51.9
N300-450HF
45
90
62.3
N300-550HF
55
110
76
N300-750HF
75
149
103
N300-900HF
90
176
122
N300-1100HF
110
217
150
N300-1320HF
132
260
180
0.1 ~ 400 Hz
3-phase 380 ~ 480 V (±10%)
50 / 60 Hz (±5%)
IGBT
Line to line sine wave PWM
200%, 0.5 Hz
150%, 1 min
DC 0 ~ 10 V, DC -10 ~ +10 V, DC 4~20 mA
3-phase 380 ~ 480 VACRatedoutput
Ratedinput
Ratedinput
12
Applied Load
[ Fan, Pump Dedicated Inverter ]
∷2 x Load such as fan, pump, blower, etc.
Features
∷High energy saving-automatic running mode
- Voltage control application to run motor with a minimum current - installed
energy saving operation mode as standard
∷Easy to maintenance
- Easy to replace cooling fan and smooth capacitor and easy to reconnect for
detachable control board
∷Compact size
- Thermal analysis and vibration analysis making optimization of components
position and miniaturization
∷User-friendly operational environment
- User group function allows customers to select menus
∷Various communication protocol
∷Lower main board and power board noise
- Lower the effect to the sensor and paralleled devices
Series
PK
Series
hiRUN N-Series
ModelType
[ A-Type ]
W D H
A
B
N300-055~075LFP/HFP
N300-110~150LFP/HFP
N300-185~300LFP/HFP
N300-370LFP/HFP
N300-450~550LFP/HFP, 750HFP
N300-750LFP
N300-900~1100HFP
N300-1320~1600HFP
150
210
250
310
390
480
390
480
Unit : mm
140
170
190
195
250
250
270
270
255
260
390
540
550
700
700
740
W
H
D
[ B-Type ]
W
H
D
Dimension
13HYUNDAI INVERTER
h i R U N N - S e r i e s
N300-P Series Type
Motor (kW)
3-phase 200 V
3-phase 400 V
5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160
Standard Specification (400 V Class)
Model400 V Class
Motor capacity (kW)
Rated current (A)
Rated power (kVA)
Output voltage (V)
Output frequency range
Input voltage (V)
Frequency
Power transistor
Control method
Starting torque
Overload capacity
Analog input command
Weight (kg)
N300-055HFP
5.5
11
7.6
3.5 3.5 5 5 12 12 12 20 30 30 30 60 60 80 80
N300-075HFP
7.5
15
10.4
N300-110HFP
11
22
15.2
N300-150HFP
15
29
20
N300-185HFP
18.5
37
25.6
N300-220HFP
22
43
29.7
N300-300HFP
30
57
39.4
N300-370HFP
37
70
48.4
N300-450HFP
45
85
58.8
N300-550HFP
55
105
72.7
N300-750HFP
75
135
93.5
N300-900HFP
90
160
110.8
N300-1100HFP
110
195
135
N300-1320HFP
132
230
159.3
0.1 ~ 400 Hz
3-phase 380 ~ 480 V (±10%)
50 / 60 Hz (±5%)
IGBT
Line to line sine wave PWM
150%, 0.5 Hz
120%, 1 min
DC 0 ~ 10 V, DC -10 ~ +10 V, DC 4~20 mA
3-phase 380 ~ 480 VAC
Standard Specification (200 V Class)
Model
200 V Class
Motor capacity (kW)
Rated current (A)
Rated power (kVA)
Output voltage (V)
Output frequency range
Input voltage (V)
Frequency
Power transistor
Control method
Starting torque
Overload capacity
Analog input command
Weight (kg)
N300-055LFP
5.5
22
7.6
3.5 3.5 5 5 12 12 12 20 30 30 50
N300-075LFP
7.5
30
10.4
N300-110LFP
11
44
15.2
N300-150LFP
15
58
20
N300-185LFP
18.5
73
25.2
N300-220LFP
22
85
29.4
N300-300LFP
30
113
39.1
N300-370LFP
37
140
48.4
N300-450LFP
45
169
58.5
N300-550LFP
55
210
72.7
N300-750LFP
75
270
93.5
0.1 ~ 400 Hz
3-phase 200 ~ 240 V (±10%)
50 / 60 Hz (±5%)
IGBT
Line to line sine wave PWM
150%, 0.5 Hz
120%, 1 min
DC 0 ~ 10 V, DC -10 ~ +10 V, DC 4~20 mA
3-phase 200 ~ 240 VAC
N300-1600HFP
160
295
204
Ratedoutput
Ratedoutput
Ratedinput
Ratedinput
14
Features
∷Minimized size
- Economical installation space
∷LCD display operator installation
- Parameter download function
- Proper words on the display to improve readability
∷ Internal PID control function
- Control PID value such as flow, velocity, etc. by internal PID control function
∷More convenient user interface
- MMI using RS-485 communication
- Parameter values display & remote setting function
- Pretest by simulation function according to the load classification
∷ Improved troubleshooting
- Trace date save function for the specified time during trip to advance
maintenance function
Series PKSeries
hiRUN N-Series
[ Medium Voltage Vector Inverter ]
15HYUNDAI INVERTER
h i R U N N - S e r i e s
Standard Specification (400 V Class)
Model
Standard Fan, Pump only
Motor capacity (kW)
Rated current (A)
Overload capacity
Rated output voltage
Output voltage method
Control method
Starting torque
Output frequency range
Digital I/O
Analog I/O
Analog input command
Weight (kg)
N500-1600HF
160
308
N500-2200HF
220
424
N500-2800HF
280
525
N500-3500HF
350
656
N500-2000HFP
200
385
N500-2800HFP
280
525
N500-3200HFP
320
616
N500-3800HFP
380
732
3-phase 380 ~ 480 V (±10%), 50/60 Hz (Complying with input voltage)
Space vector PWM
V/F control, seneorless vector control, sensored vector control
200%, 0.5 Hz
0.1 ~ 400 Hz
Multi-function digital input 8 channel, multi-function open collector output 5 channel,
multi-function C contact output 2 channel
Voltage / current output 2 channel, pulse output 1 channel
DC 0 ~ 10 V, DC -10 ~ +10 V, DC 4~20 mA
150%, 1 min 120%, 1 min
Dimension
Model W H D
N500-1600HF
N500-2200HF
N500-2000HFP
N500-2800HFP
N500-2800HF
N500-3500HF
N500-3200HFP
N500-3800HFP
N500-2200HFK
620
620
620
620
800
800
800
800
620
Unit : mm
750
750
750
750
1150
1150
1150
1150
930
380
380
380
380
380
380
380
380
380
Ratedoutput
H
W D
180 180 215 215 180 180 215 215
N500 Series Type
Motor(kW)
3-phase 400 VStandard
Fan, Pump only
160 200 220 280 320 350 380
3-phase 400 V
Features
∷Environment-friendly system to meet harmonic waves rule
(IEEE519-1992) by serialized multiplex drive
∷High power factor and electric conversion efficiency
∷High efficient operation by sensorless vector control
∷Economic installation by slimming
∷Easy maintenance by modularization
∷Easy operation by one touch screen digital operator
∷Remote console on user-friendly windows OS
SeriesSeries
[ High Voltage Mega Capacity Vector Inverter (Voltage Type) ]
PK
Dimension
H
W D
Model W H D
N5000-3450
N5000-3600
N5000-3900
N5000-311H
N5000-315H
N5000-6900
N5000-612H
N5000-618H
N5000-623H
N5000-630H
2200
Unit : mm
2750 1230
2600
30003700 2750 1550
2750
2750
1230
1400
3800 2750 1230
4200
46005600
2750
27502750
1230
14001550
16 hiRUN N-Series
h i R U N N - S e r i e s
Standard Specification
17HYUNDAI INVERTER
Model
Motor capacity (kW)
Rated current (A)
Rated capacity (kVA)
Input voltage
Output voltage (V)
Output frequency range
Modulation method
Control method
Output current THD
Power factor
Efficiency
Rated overload
Protection
Ambient temperature
Cooling method
Communication method
Input / Output signal
N5000-3450
N5000-3600
N5000-3900
N5000-311H
N5000-315H
N5000-6900H
N5000-612H
N5000-618H
N5000-623H
N5000-630H
450
105
600
600
140
800
900
210
1200
1125
260
1500
1500
350
2000
900
105
1200
1200
140
1600
1800
210
2400
2250
260
3000
3000
350
4000
3-phase AC 3300 V ± 10%, 50/60 Hz ± 5% 3-phase AC 6600 V ± 10%, 50/60 Hz ± 5%
3-phase, 0 ~ 3300 V, line voltage 3-phase, 0 ~ 6600V, line voltage
0 ~ 120 Hz
Pulse width modulation (optical fiber signal)
V/F control, sensorless vector control, sensored vector control
THD < 4%
P.F ≥ 0.95 (at from 30% to 100% load)
97% (at rated speed & rated load)
120% / 60 sec, 150% / 60 sec (Option)
Overcurrent, output terminal, ground fault, input phase disequilibrium, DC overvoltage &
overcurrent, transformer overheat, motor overheat CELL inverter overheat, communication error
0 ~ 40
Forced cooling method
RS232 1CH, RS485 2CH
Digital input/output : 16channel/8channel (Dry Contact)
Analog input/output : 8channel/2channel (4 ~ 20 mA, or 0 ~ 10 V)
N5000 Series Type
Motor(kW)
3300 V Class
450 600 900 1125 1200 1500 1800 2250 3000
6600 V Class
HH
IS-W
C-C
E-A
22- 01, 2006.4 Designed by D
esign Korea
www.hyundai-elec.com
Head Office 1 Jeonha-dong, Dong-gu, Ulsan, Korea Tel. 82-52-230-8101~8 Fax. 82-52-230-8100
Seoul HYUNDAI B/D, 140-2, Gye-dong, Jongno-gu, Seoul, Korea (Sales & Marketing) Tel. 82-2-746-7596, 7519 Fax. 82-2-746-7648
Orlando 3452 Lake Lynda Drive, Suite 110, Orlando, Florida U.S.A. 32817 Tel. 1-407-249-7350 Fax.1-407-275-4940
London 2nd Floor, The Triangle, 5-17 Hammersmith Grove London, W6 0LG, UKTel. 44-20-8741-0501 Fax. 44-20-8741-5620
Tokyo 8th Fl., Yurakucho Denki Bldg.1-7-1, Yuraku-cho, Chiyoda-gu, Tokyo, Japan 100-0006Tel. 81-3-3212-2076, 3215-7159 Fax. 81-3-3211-2093
Cairo Apartment No. 503, 5th Fl., Bldg. No. 7 Block 2, 9th Division, El-nasr Road, New Maadi, Cairo, EgyptTel. 20-2-520-0148~9 Fax. 20-2-754-7528
Sofia 41, Rojen Blvd. 1271, Sofia BulgariaTel. 359-2-938-1068, 936-0300 Fax. 359-2-936-0742
Yangzhong Lianzhong Avenue, Xinba Scientific and Technologic Zone, Yangzhong City, Jiangsu Province, China(212-212)(Jiangsu Hyundai Nanzi Electric Co., Ltd.)Tel. 86-511-842-0666, 0212 Fax. 86-511-842-0668, 0231