+ All Categories
Home > Documents > PowerPoint Presentation Expo... ·  · 2015-04-20Resistive touch screen Ethernet with embedded...

PowerPoint Presentation Expo... ·  · 2015-04-20Resistive touch screen Ethernet with embedded...

Date post: 02-May-2018
Category:
Upload: phamquynh
View: 214 times
Download: 2 times
Share this document with a friend
44
Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Panelview Plus 7 New Features & Functions plus Mobility VI01
Transcript

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Panelview Plus 7 New Features & Functions

plus Mobility

VI01

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Keith Krings – Werner Electric

Tom Steffen – Rockwell Automation

Presenters

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

• VI02 – Intro to Factory talk View ME 8.0

lab

• AD06 – Studio 5000 Best Practices

• AD07 – Studio 5000 New Features and

Benefits

• AD09 – Intro to Logix Hands-on lab

• AD10 – Logix Integration Hands-on Lab

Related Sessions

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Agenda

FTViewME 8.0 Features

Panelview Plus 7 Models and Features

Remote Access Options

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Portfolio

PanelView Classic PanelView Standard

PanelView Enhanced

PanelView Plus

PanelView Plus

Compact

PanelView Plus 6

An evolution of graphic terminals since 1989

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Portfolio

PanelView Classic PanelView Standard

PanelView Enhanced

PanelView Plus

PanelView Plus

Compact

PanelView Plus 6

… PanelView

Plus 7

Since 1989

PanelView Plus 7 extends the portfolio

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 7

• Extends offering and

functionality –PanelView Plus 7 standard

model

–PanelView Plus 7 performance

model

• New form factor –Common to future IA operator

interfaces

–Adapter plates for PanelView

Plus 6 or PanelView Plus retrofit

Features

Widescreens

New Display Sizes

ATEX (select models)

Ethernet with embedded switch (DLR)

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 7 Models

Performance Standard

6.5”, 9”W, 10.4”, 12”W, 15”, 19”

Low profile painted aluminum bezel

Resistive touch screen with keypad

options

Ethernet with embedded switch

X86 processor

1 GB Flash Memory / 512 MB RAM

Windows CE 6.0 extended features

DC and AC power options

Targeted at larger / complex applications

4.3”W, 5.7”, 6.5”, 9”W, 10.4”, 12”W, 15”

Low profile plastic bezel

Resistive touch screen

Ethernet with embedded switch and

single Ethernet option on 4.3” to 10.4”

ARM processor

512 MB Flash Memory / 512 MB RAM

Windows CE 6.0 standard features

DC powered

Targeted for simpler / smaller applications

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 7 Features

Product Features PanelView Plus 7 Standard model

PanelView Plus 7 Performance model

FactoryTalk Machine Edition Y Y

ViewPoint Y Y

Memory RAM / Flash 512 MB / 512 MB 512MB / 1 GB

PDF Viewer Y Y

Active X Controls (Email, DataStorePlus, Recipe) Y Y

Remote Terminal Control (Based on VNC) Y Y

FTP Server Y Y

MPEG Video playback N Y

Microsoft Office Viewers N Y

Microsoft Internet Explorer N Y

Remote Desktop Services N Y

Ethernet Connectivity Y (Single Only) Y (DLR Only)

CPU ARM 1Ghz x86 1.6Ghz

Screen Sizes 4.3”-15” 7”-19”

Application Sizes 1 Controller, 25 Screens,

200 Alarms Larger Applications

Catalog numbers 2711P-xxxxx8S 2711P-xxxxx9P

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 7 Ethernet Connectivity

PanelView Plus 7 Performance line comes with an embedded switch (DLR).

PanelView Plus 7 Standard version include an embedded

Ethernet Port.

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 7 Features

• Communication options on the PVP7:

– Ethernet Only

– Standard 4”-15” Single Port

– Performance 7”-19” DLR

• Screen resolutions for PanelView Plus 7

Standard and Performance are the same.

Size Resolution X Y

4” Wide WQVGA 480 272

6” VGA 640 480

7” VGA 640 480

9” Wide WQVGA 800 480

10 SVGA 800 600

12” Wide

WXGA 1280 800

15” XGA 1024 768

19” SXGA 1280 1024

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 7 SD Card Data Storage

Quick and Easy Terminal Copy & Restore

Use an SD card to quickly create copies of a terminal to reduce your time to market or restore a terminal.

• Operating system

• Network configuration and terminal settings

• FactoryTalk® View Machine Edition (ME) runtime file

• Datalogs and Recipe files

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 7 Release Schedule

Released

Standard Models

• 4”-10”

• Single Ethernet

• Associated Accessories

Release 2 – Q3 / 2015

Additional Standard Models

• 12” and 15” single Ethernet

Performance Models

• 7” – 19” all DLR

• Associated accessories

Adapter Plates

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 7 Standard

Decrease time to market… Increased screen resolution…

Standard Model – Single Ethernet

– Machine Builder Focus

– Sizes: 4”-10” / 12”-15” Summer 2015

– Single Ethernet

– Touch Screen

– Low Profile, Composite Bezel

– FactoryTalk View Machine Edition -

supporting MER files back to 3.2

– 5 Catalogs – Allen-Bradley Branded

– 5 Catalogs – No Branding

Widescreens ….. New Display Sizes….. ATEX Certifications …..

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 7 Standard Features & Benefits

Standard

4.3”W, 5.7”, 6.5”, 9”W, 10.4”, 12”W, 15”

Low profile composite bezel

Resistive touch screen

Single port Ethernet

ARM processor

512 MB Flash Memory / 512 MB RAM

Windows CE 6.0 standard features

DC powered

Removable Battery

Targeted for simpler / smaller applications

ATEX Certification, Class 1 Div. 2

Machine Builder Focused

• OEM Optimized Design

• Expanded Processing Power

• Composite bezel

• Competitive Solution

• More screen options

• Greater resolution

• Wide screen options

• Application Size Limits

• 1 Controller

• ≤25 Screens

• ≤200 Alarms

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 7 Standard Release 1

Accessories

Mounting Levers - 2711P-RMCS

SD Card Covers - 2711P-RCKS

DC Terminal Blocks - 2711P-RTBDSP

Protective Overlays - 2711P-RGTxS (x is terminal size)

Battery Covers - 2711P-RYKS

Catalog Number PanelView Plus 7 Standard EOI Description

2711P-T4W21D8S 4” WQVGA TFT color, Touch, DC powered, Single Ethernet port 2711P-T6C21D8S 6” VGA TFT color, Touch, DC powered, Single Ethernet port 2711P-T7C21D8S 7” VGA TFT color, Touch, DC powered, Single Ethernet port 2711P-T9W21D8S 9” WVGA TFT color, Touch, DC powered, Single Ethernet port 2711P-T10C21D8S 10” SVGA TFT color, Touch, DC powered, Single Ethernet port

2711P-T4W21D8S-B 4” WQVGA TFT color, Touch, DC powered, Single Ethernet port, with blank bezel

2711P-T6C21D8S-B 6”VGA TFT color, Touch, DC powered, Single Ethernet port, with blank bezel 2711P-T7C21D8S-B 7” VGA TFT color, Touch, DC powered, Single Ethernet port, with blank bezel

2711P-T9W21D8S-B 9” WVGA TFT color, Touch, DC powered, Single Ethernet port, with blank bezel

2711P-T10C21D8S-B 10” SVGA TFT color, Touch, DC powered, Single Ethernet port, with blank bezel

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 7 Standard Anatomy

Mobile ready with VNC support and FactoryTalk Viewpoint

ATEX and UL Class 1, Div 2

for demanding environments

With the embedded PDF Viewer, show:

• User Manuals

• Installation Manuals

• SOPs (Standard Operating Procedures)

Faceplates and Add-on Instructions can

save 50 – 90% of complex screen development time

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 6 Compact vs

PanelView Plus 7 Standard display

sizes

4.3 in.

wide

(480x272)

5.7 in.

(640x480)

6.5 in.

(640x480)

9.0 in.

wide

(800x480)

12.1 in. wide

(1280x800)

10.4 in.

(800x600)

15.0 in.

(1024x768)

3.5 in.

(320x240)

5.7 in.

(320x240)

10.4 in.

(640x480)

More Screens Sizes and Greater Resolution to Chose From.

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

PanelView Plus 7 Standard Anatomy

SD storage card slot for data

storage and terminal replication

USB Ports for quick upload

and download to the terminal

New installation clamps provide

fast and simple terminal

installation and removal

Embedded Ethernet port for

connectivity from the machine to the enterprise

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

FactoryTalk View ME v8.0

• Each project has its own private security configuration

• Restore a project (MER/APA) without overwriting any other project’s security configuration

Design-time security

• Allows panel to authenticate with Server 2008/2012 domains

• Requires LDAP support to be enabled in end-user’s domain

Updated Domain authentication

• Add and delete FactoryTalk users during runtime

• Change user’s group membership during runtime

Runtime user management

• Windows 8 and Windows Server 2012 Support

• PanelView 7 Support

Compatibility

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Feature Cheat Sheet

• Support New PanelView Plus 7

• Simplified project maintenance

• Added domain authentication options

• Enhanced Login button provides domain field

• Manage security configuration within a running application

• Improved audit trail

• New error-proofing features

• Changes to Security Codes

• Installation enhancements

• Compatibility with additional OS

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Simplified Project Maintenance

• Improved handling of multiple FTView

Machine Editions applications on same PC

– Each project has its own private security

configuration

– Allows user to restore a project (MER/APA)

without overwriting any other project’s security

configuration

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

How Security Works Before v8.0

Public Local FactoryTalk Directory

Users & Groups

Project A

Project B

RSLinx Config.

Project C

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

How Security Works In v8.0

Project A

Private Local

FactoryTalk Directory

Users & Groups

RSLinx Config

Project B

Private Local

FactoryTalk Directory

Users & Groups

RSLinx Config

Project C

Private Local

FactoryTalk Directory

Users & Groups

RSLinx Config

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Design-time Security Changes

What Do They Mean To Me?

• Each ME application’s security configuration is unique

• No need to be ‘careful’ when restoring MER or APA – No more prompt to restore FTDir, or not, when restoring an

APA/MER

• Must manage security (user, groups, policy) from ME Project Explorer tree – FTAdmin does not work with or recognize the private local

FTDir associated with each ME application

• Must use a ‘template’ project to have a common set of users & groups – Use App Mgr to copy ‘template’ to new project before starting

– Cannot move, copy, or backup/restore users & groups between projects

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Design-time Security Changes

What Do They Mean To Me?

• When creating a new pre-8.0 MER, the system converts from the private

local FTDir to the necessary format; no restrictions

• V8.0 ME Station, on a PC, continues to use the public local FTDir

• Slight delay working with applications (new, open, rename, copy, etc.)

– Delays optimized for New Application and Open Application operation

– Typical delays are < 135% of current 7.0 performance

• Ex a 7.0 operation that took 30s, it might now take ~40s

• Application Manager Copy, Rename, and Delete can only operate on

applications that have been opened with FTView Studio v8.0

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Added Domain Authentication Options

• Support Windows Server 2008 & 2012 Domain authentication

– Requires domain enables LDAP support

– Requires additional configuration in ME Station for LDAP

– Can use LDAP or LDAP Over SSL

• LDAP Over SSL encrypts the user credentials

• LDAP over SSL requires certificate to be moved (manually) to terminal

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Login Button enhancements

support Domain

• Added optional DOMAIN field to login button

• At run-time DOMAIN field can be

– Fixed text

– User entered

– Content of a tag

• HMI designer can control

– Visibility of DOMAIN field

– Editability of DOMAIN field

– Tie DOMAIN field to a tag via Connection property

– Obscure user name (‘#’ shown instead of characters)

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Domain Authentication Changes

What Do They Mean To Me?

• Supports Windows Server 2008 & 2012 Domain authentication

• Existing application will work in Windows 2008/2012 domains, unchanged – LDAP configuration applies to the terminal, not the application

– Domain authentication is handled by FTSP on the terminal • Application asks FTSP to authenticate the user with the provided

credentials; FTSP determines which calls Windows or LDAP calls to make

• When authenticating the system will ALWAYS attempts Windows authentication API calls before LDAP – System switches to LDAP if Windows Authentication API fail

• When using LDAP over SSL a certificate must be manually moved to the terminal using a USB stick or SD card

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Manage User Security @ Run-time

• Modify security configuration in a running ME application – Change any FactoryTalk user’s password

– Add FactoryTalk or Windows-linked user, or Windows-linked group

– Delete FactoryTalk or Windows-linked user, or Windows-linked group

– Change FactoryTalk or Windows-linked user’s, or Windows-linked group, group membership

– Change FactoryTalk user’s account properties

– Change logged in FactoryTalk user’s password

– Enable / Disable FactoryTalk user

– Unlock FactoryTalk user

• Security configuration changes persisted in the MER – Don’t lose change when upload and restore the MER

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Improved Error-proofing

• When building MER for a PanelView Plus terminal, system warns if a shortcut uses an unsupported network, Ex. RIO

• When loading MER on PanelView Plus terminal will warn if

– MER project resolution (size or aspect ratio) does not match physical terminal

– MER contains shortcut(s) using network physical terminal does not support, Ex. PanelView Plus 7 and DH+

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Runtime Security Enhancements to

Security Codes (A-P)

• In v8.0 ME Station, PanelView Plus or PC, at run-time, if a user is a member of

more than one A-P configuration, then the user’s effective Security Code A-P

permissions will be the most restricted set; previous versions granted the most

lenient effective Security Code A-P permissions

Example

– Bob, a FactoryTalk user, is a member of two FactoryTalk groups, Group1 and

Group2

– In the Design-time application using FactoryTalk View Studio, Runtime

Security is configured as shown ; only codes A-D are shown for simplicity

– Bob’s effective Security Codes in the running application are shown

below.

Runtime Security Configuration A B C D

Group1 X X X

Group2 X X X

Effective Security Codes A B C D

FactoryTalk View 7.0, and earlier X X X X

FactoryTalk View 8.0 X X

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Runtime Security Enhancements to

Security Codes (A-P)

• How can a user be a member of more than one A-P Security Code configuration – FactoryTalk or Windows-linked User explicitly configured in

Runtime Security more than once

– FactoryTalk or Windows-linked User is a member of more than one configured FactoryTalk Groups in Runtime Security

– FactoryTalk or Windows-linked User is a member of one or more FactoryTalk Group(s) configured in Runtime Security and the user is also explicitly configured in Runtime Security

– Windows-link User is a member of a Windows-linked group, the Windows-linked group is a member of more than one FactoryTalk Groups configured in Runtime Security

– Windows-linked User is a member of a Windows-linked group, the Windows-linked group is a member of one or more FactoryTalk Group(s) and the Windows-linked user is also explicitly configured in Runtime Security

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

More Easily Manage Alarms

• Resizable alarm editor

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

More Easily Manage Alarms

• Resizable alarm editor

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Improved Application Manager

Workflow

• Application Manager behavior changed to return to starting step when an operation completes so user can immediately initiate next operation

• Application Manager now allows the user to overwrite existing backup (APA) files when creating a backup file

• Application Manager now allows the user to overwrite an existing project when restoring a backup (APA) or runtime (MER) file

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Better Auditing

37

• Audit messages reflect ‘old’ data and ‘new’

data

• FTAsset Centre

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Installation Improvements

• Unattended Installation mode

– Supports an ‘Answer File’ to pre-configure

installation options

– Can be used with Application Management

software (Ex. Altiris)

• Optimization of DVD content to reduce

download size

• Inhibit install on unsupported OS

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Additional Platforms and

Operating System Support

• Windows Operating Systems

– Windows 8 Professional 7 Enterprise (32- and 64-bit)

– Windows 8.1 Professional 7 Enterprise (32- and 64-bit)

– Windows Server 2012 Standard (64-bit)

– Windows Server 2012 R2 Standard (64-bit)

• PanelView Plus Platforms

– PanelView Plus 6 Compact 1000

– PanelView Plus 7 Standard

– PanelView Plus 7 Performance

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Removing Platforms and

Operating System Support

• FactoryTalk View 8.0 is the LAST release to support v 3.2 and v4.0 MER – Using release after v8.0, it is not possible to create

v3.2 or v4.0 MER

– Using release after v8.0, it is not possible to execute v3.2 or v4.0 MER

– Using release after v8.0, it IS possible to open and convert legacy applications the newer format

• FactoryTalk View v8.0 is the LAST release to support – Windows XP [any edition or SP]

– Windows Vista [any edition or SP]

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

• Would productivity increase by allowing your operators remote

access to terminal data from a remote location?

– New Server Enablement on PanelView Plus 7 supports two VNC client

connections

– Variety of remote connection technologies, including terminal-to-terminal

communication

PanelView Plus 7 Mobility Options

Knowledgebase Note 466394

Technology

FTP

VNC

ViewPoint

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

What if you needed info quickly : – Unit count – Read alarm data – Review trend data… etc

But you were no where near your computer or the line?

Technology Tools to Enhance

Experience

Pocket

Cloud

Motorola ET1

Client “Server”

VNC

Stationary

View

Extendable

View

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved. Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

• Sessions

• VI02 – Intro to Factory talk View ME 8.0 lab

• AD06 – Studio 5000 Best Practices

• AD07 – Studio 5000 New Features and Benefits

• AD09 – Intro to Logix Hands-on lab

• AD10 – Logix Integration Hands-on Lab

• Tradeshow

• Solution Area 3 – Process & Connected Enterprise

Where can I learn more?

Copyright © 2014 Rockwell Automation, Inc. All Rights Reserved.

Questions?

VI02


Recommended