55
CS 2100 & CS 2200 Our Next Generation Intraoral X-ray Systems Public © Carestream Health, 2014
Transcript

CS 2100 & CS 2200

Our Next Generation Intraoral X-ray Systems

Public © Carestream Health, 2014

CS 2100 & CS 2200

• Product introduction

• Product enhancements

• CS 2100

• CS 2200

• Irix mounting configuration

• Options and accessories

p.2

Public © Carestream Health, 2014

CS 2100 & CS 2200

Next Generation CS 2100

• Affordable, high frequency technology

• Designed for dental professionals seeking ease of use and reliability

• Provides high quality results for accurate and safe diagnostics.

• Flexible and smart design helps meet the needs of almost any practice

CS 2100 & CS 2200

Next Generation CS 2200

• Improved design for added durability and reliability

• Designed with safety, comfort and efficiency in mind

• High frequency generator supports superior image quality and better safety conditions for your patients and staff

• Features an intuitive timer

CS 2100 & CS 2200

Next Generation CS 2200

• Timer interface improves the user-friendliness and the reliability

• Complies with modern quality control and Euratom directives

– Regarding failsafe procedures

– Emitted dose display for better patient dose tracking

• Interface is very intuitive and easy-to-use.

• Makes exposure setting failsafe and helps avoid retakes – User friendly and intuitive interface

– Simplification of the exposure setting process

– Clear displays, allowing easier reading even from distant location

• Timer includes a complete diagnostic tool for easier servicing by technicians, which helps improve uptime

What is the role of the CS 2100 and CS 2200?

• Intraoral generators are a key component of Carestream Dental Systems total intraoral solution, which includes:

– X-ray tube manufacturing

– Image capture technology

– Imaging software

• Intraoral products are designed to work together seamlessly

CS 2100 & CS 2200

PRODUCT ENHANCEMENTS CS 2100 & CS 2200

p.7

Public © Carestream Health, 2014

Reliability is Our Key Goal

GOAL:

To work to continuously improve the reliability of our

CS 2100 and CS 2200 Intraoral X-Ray Systems

We have implemented the following changes:

• Modified the manufacturing process to improve product quality

• Improved the materials used in manufacturing

• Changed the product design to improve reliability

• Introduced new system components used in manufacturing

• Improved the testing process for each unit, both during manufacturing and upon completion

• Simplified the installation process via product enhancement and a Quick Start Guide

p.8

Public © Carestream Health, 2014

Improvements to Generator Head

p.9

© Carestream Health, 2014

New cable wiring and welding

process

Wire protection

New fork

cover

Improved Electronic

Board

100% Test of Tank Lid

100% Test of

Connector

New design New material

E13 cut HTR power

E14 HT internal sparking

External wire cut at connector

Oil leakage

New start up procedure and

Quick User Guide

ERROR CODES

Improvements to Wall Mount and Arm

p.10

© Carestream Health, 2014

Inversed mount

New bolts for

electronic board protection

Pre-wired clip-on connectors

Insulation plate

Electronic board damaged at installation

Easier installation

Simplified installation software

Pre-wired clip-on connectors incl

2100 New brake material

Pre-wired clip-on connectors

Cable sheath

Modified fixation holes

ERROR CODES

Additional Product Improvements

• 100% unit testing has been implemented

–Additional tests of the connector and tank lid will also be performed during manufacturing

–Each unit will be tested after full assembly

• Packaging has been adapted

–Packaging now includes handles for easier movement

–Package can be placed flat on long edge or stood upright

• A Quick Start Installation Guide

–Reminds and guides users through restarting procedure

–Addresses seasoning needs

• Manuals have been updated

–Reflect changes to the products

–Facilitate maintenance, diagnostics and parts replacement

p.11

© Carestream Health, 2014

New updated packaging showing redesigned handles

CS 2100 Introducing the Next Generation

Benefits

• Affordable, yet feature-rich intraoral imaging

• DC technology (Very High Frequency), replacing AC technology

–Dose reduction (up to 30%) thanks to the VHF

–Better control of exposure parameters: reproducibility and consistency

• Extremely simple to use

• User-friendly exposure time selection button

• Dose display after each exposure

• Ergonomic design

• Full range of options and accessories that maximise the overall flexibility of the unit

• Improved servicing

Timer

Unique, easy to use timer with multiple functions:

• Timer

– Manual time setting

– Film / Digital mode

• Emitted dose display

• User Menu

– Settings customization

– Tube seasoning

• Technical Menus

– Interface with firmware

– 2 counters for exposures

– Up to 59 management error codes

– Calibrated generator parameters

Installation Layouts

Left orientation Right orientation Vertical orientation

Configurations STANDARD CONFIGURATION

Standard 2-wire cable

Remote timer. Can be located anywhere from close to the unit to outside of the operating room

Timer can also be mounted on the wall-framework (fixing kit and link cable supplied in std configuration).

A reliable and ergonomic designed exposure button to trigger each exposures.

OPTIONAL CONFIGURATION (with additional Cat 5154307 accessory)

3 over-twinned pairs + 1 shield cable

Why 60 kV DC ?

More penetrating x-ray beam is consecutive to a technology change from AC to DC (VHF). Consequently, to match radiographic contrast obtained with Irix 70kV AC , beam energy has to be reduced down from 70 to 60kV DC.

DC-VHF

AC

kV 70 kV - AC

70 kV - DC

60 kV - DC

70 kV - AC

70 kV - DC

60 kV - DC

X-ray energy levels

Dis

trib

utio

n Resulting radiographic contrast

Reduction of soft radiations (low energies)

70 kV AC vs 60 kV DC

18

Technical Specifications MEASUREMENT VALUE

Tube Voltage 60 kV

Tube Current 7 mA

Frequency 300 kHz Very High Frequency

Tube Focal Spot 0.7 mm CEI

Total Filtration 2.5 mm eq. AI

Input Voltage 230-240 V – 50/60 Hz

Weight ~ 18 kg - ~ 40 lbs

3 arm lengths available: Short (170 cm / 67 in.); Standard (188 cm / 74 in.); Long (205 cm / 81 in.)

Accessories: Mobile stand Floor mounting column Rectangular collimators (size A, B and C), ….

Mounting options: Standard wall mount Ceiling mount

Dimensions

514 mm

214

mm

1007

mm

819

mm

2072

mm

39-5

/8in

.

20-1/4in.

B

47-1

/4in

.

80 mm

1200

mm

3-1/8in.R

C

32-1

/4in

.8-

7/16

in.

A

81-9

/16i

n.

N :

1.9 mm

Al

par arrete du :

Filt tot :HT : 70 kVTUBE N :

TYPE HOM

OLO

GUE s

o

o

oTYPE :

81-1

/2in

.20

72 m

m

47-1

/4in

.12

00 m

m

R

16-5

/16i

n.41

5 m

m

39-5

/8in

.10

07 m

m

300°

63in

.16

00 m

m

1-3/4in.44 mm

B

A

12-1/4in.310 mm

11-15/16in.303 mm

20

Cat Numbers There are 5 Cat Numbers for 230 V systems

Cat Number Description

5153671 CS 2100 230V / 170 cm Short Wall Mount

5153663 CS 2100 230V / 188 cm Standard Wall Mount

5153655 CS 2100 230V / 205 cm Long Wall Mount

5154349 CS 2100 230V / Ceiling Mount

5155304 CS 2100 230V / Ceiling Mount Faro

21

Cat Numbers There are 4 Cat Numbers for 110 V systems

Cat Number Description

5153648 CS 2100 110V / 170 cm Short Wall Mount

5153630 CS 2100 110V / 188 cm Standard Wall Mount

5153622 CS 2100 110V / 205 cm Long Wall Mount

5154356 CS 2100 110V / Ceiling Mount

CS 2200 Introducing the Next Generation

Benefits

• Choice between 60 or 70 kV for high contrast or high latitude images

• DC technology (Very High Frequency technology)

–Dose reduction (up to 30%) thanks to the VHF

–Better control of exposure parameters: reproducibility and consistency

• One level of mA (7 mA): simplification, shorter exposure times, failsafe, reduction of motion blur

• Hand-held timer for freedom of movement in the practice

• Easy-to-use, intuitive and failsafe timer

• Simplified and mistake-proof setting of exposure parameters

• Dose display after each exposure

• Full range of options and accessories that maximise the overall flexibility of the unit

• Improved servicing

Timer

Multiple user functions:

• Exposure settings

– 60 / 70 kV

– 3 patient sizes: child / adult / large patient

– 3 pre-set modes: phosphor plate/digital/film

– 1 manual mode timer

– 1 intuitive tooth selection wheel:

– incisor / premolar / molar - maxillary or mandibular – Bite-wing anterior / posterior - Occlusal

• Emitted dose display

Timer

Multiple service functions:

• User Menu

– Settings adjustments

– Tube seasoning

• Technical Menus

– Interface with firmware

– 2 counters for exposures

– Up to 59 management error codes

– Calibrated generator parameters

Installation Layouts

Left orientation Right orientation Vertical orientation

Configurations STANDARD CONFIGURATION

3 over-twinned pairs + 1 shield cable included in the accessory

Timer can also be mounted remotely on the wall.

OPTIONAL CONFIGURATION (with additional Cat 5159678 accessory)

Timer is fixed on the wall apply with a back magnetic plate.

60kV and 70kV DC

• Selecting 60 or 70 kV will adjust the contrast (gray shade) levels of the radiographic image

• Provides the dentist freedom of choice according to the type of examination (periodontics, endodontics), diagnostic standards, and the morphology of the patient

• 60 kV will provide radiographs with high contrast

• 70 kV will provide radiographs with high latitude, and with additional dose reduction

70 kV - DC

60 kV - DC

Resulting radiographic contrast

29

Technical Specifications MEASUREMENT VALUE

Tube Voltage 60 kV – 70 kV

Tube Current 7 mA

Frequency 300 kHz Very High Frequency

Tube Focal Spot 0.7 mm CEI

Total Filtration 2.5 mm eq. AI

Input Voltage 230-240 V – 50/60 Hz

Weight ~ 18 kg - ~ 40 lbs

3 arm lengths available: Short (170 cm / 67 in.); Standard (188 cm / 74 in.); Long (205 cm / 81 in.)

Accessories: Mobile stand Floor mounting column Rectangular collimators (size A, B and C), ….

Mounting options: Standard wall mount Ceiling mount

Dimensions

31

Cat Numbers There are 5 Cat Numbers for 230 V Systems

Cat Number Description

5153580 CS 2200 230V / 170 cm Short Wall Mount

5153572 CS 2200 230V / 188 cm Standard Wall Mount

5153564 CS 2200 230V / 205 cm Long Wall Mount

5154331 CS 2200 230V / Ceiling Mount

5155288 CS 2200 230V / Ceiling Mount Faro

32

Cat Numbers There are 4 Cat Numbers for 110 V Systems

Cat Number Description

5153614 CS 2200 110V / 170 cm Short Wall Mount

5153606 CS 2200 110V / 188 cm Standard Wall Mount

5153598 CS 2200 110V / 205 cm Long Wall Mount

5154323 CS 2200 110V / Ceiling Mount

CS 2200

IRIX Mounting Configuration

Benefits

• Use of Trophy Irix anchorage points (and Gendex Oralix AC)

• No impact to existing practice environment

• Simplified installation

• DC technology (Very High Frequency technology) –Dose reduction (up to 30%) thanks to the VHF –Better control of exposure parameters: reproducibility and consistency

• Choice between 60 or 70 kV for high contrast or high latitude images

• One level of mA (7 mA): simplification, shorter exposure times, failsafe

• New easy-to-use, intuitive and failsafe interface

• Simplified and mistake-proof setting of exposure parameters

• Dose display after each exposure

• Improved servicing

Wall Mount Compatibility

Left or right orientations are possible to suite the practice environment

Anchorage points of Irix base

35

Anchorage points of Oralix AC base

Gendex Oralix AC

Trophy Irix

Irix Replacement: EASY and Fast

The former Irix unit can be replaced in less than 1 hour, using the same anchorage points and cables (power supply, exposure switch command).

There is no additional work required to redecorate the area after installation.

User’s Interface

Multiple user functions:

• Exposure settings

–60 / 70 kV

–3 patient sizes: child / adult / large patient

–3 pre-set modes: phosphor plate/digital/film

–1 manual mode timer

–1 intuitive tooth selection wheel:

– incisor / premolar / molar - maxillary or mandibular – Bite-wing, anterior / posterior, occlusal

• Emitted dose display

X-ray activation by existing switch

or supplied exposure button

User’s Interface

Multiple service functions:

• Anterior / posterior - Occlusal

• Emitted dose display

• User Menu

–Settings adjustments

–Tube seasoning

• Technical Menus

–Interface with firmware

–2 counters for exposures

–Up to 59 management error codes

–Calibrated generator parameters X-ray activation by existing switch

or supplied exposure button

Installation Layouts

Left orientation Right orientation

Configuration

X-rays are activated by a separate exposure switch.

User’s interface is attached on the wall apply. Standard 2-wire cable

41

Technical Specifications MEASUREMENT VALUE

Tube Voltage 60 kV – 70 kV

Tube Current 7 mA

Frequency 300 kHz Very High Frequency

Tube Focal Spot 0.7 mm CEI

Total Filtration 2.5 mm eq. AI

Input Voltage 230-240 V – 50/60 Hz

Weight ~ 18 kg - ~ 40 lbs

3 arm lengths available: Short (170 cm / 67 in.); Standard (188 cm / 74 in.); Long (205 cm / 81 in.)

Accessories: Rectangular collimators (size A, B and C), ….

Mounting options: wall mount

Dimensions

43

Cat Numbers There are 3 Cat Numbers (only available 230 V )

Cat Number Description

5159652 CS 2200 230V / 170 cm Short Wall Mount / Irix Mounting Configuration

5159645 CS 2200 230V / 188 cm Standard Wall Mount / Irix Mounting Configuration

5159660 CS 2200 230V / 205 cm Long Wall Mount / Irix Mounting Configuration

ACCESSORIES & OPTIONS

CS Intraoral X-ray Systems

3 Extension Arms

Extension arms available for CS2100 & CS 2200 :

Extension arm of 470 mm (18.50’’) – short 170 cm span

Extension arm of 648 mm (25.5’’) – standard 188 cm span

Extension arm of 850 mm (32.5’’) – long 205 cm span

Ceiling Mount (available for 110V & 230 V)

Ceiling Mount Faro (only available for 230 V)

Cat 5155825: Standard grip for adapting a lamp on the ceiling column

Faro Grip for adapting a Faro lightning system on the ceiling column (included in package)

Ceiling Mount

Mounting Configurations

• These mounting options are usable with both CS 2100 & CS 2200, but can only be associated with the standard wall-mounting configurations

• They are not compatible with the CS 2200 / Irix Mounting Configuration

Mounting Options

•Mobile base •Floor column stand •Counter plate •Metal plate for pass-through configuration •Irix wall mask apply

Mounting Options – Mobile base

Mobile base Cat 5154281

Must be combined together with either CS 2100 or CS 2200 / Standard wall-mounting configuration.

CE and C-UL Certified for highest safety

CS 2100 Mobile Unit

CS 2200 Mobile Unit

Mounting Options – Floor Column Stand

CS 2100 Floor Mounting Column Unit

CS 2200 Floor Mounting Column Unit

Floor column stand Cat 5154273

Must be combined together with either CS 2100 or CS 2200 / Standard wall-mounting configuration.

CE and C-UL Certified for highest safety

Installation plates

Counter plate for standard wall-mounted configurations Cat 5154265

Metal plate for pass-through configuration (US&C mainly) Cat 5188305

Irix wall mask apply Cat 5156369 (in case of horizontal layout)

Accessories for the intraoral product range

• X-ray exposure switch - Cat 5154307

(it is compulsory when mounting the CS 2100 with the timer on the wall-apply cover)

• Separate timer box for CS 2200 - Cat 5159678 (*)

(it is compulsory to mount the CS 2200 with the timer on the wall)

• Square collimator size C (delivered with the unit) for sizes 1 & 2 film/plate and size 2 sensor

• Square collimators size A and B for other smaller sized sensors and/or films/plates

(*) note: for former Trophy Elitys, Kodak 2000 or Kodak 2200 (with 4 and 7 mA), use Cat

5154315

List of Cat Numbers for Collimators

• Collimators fit the size of imaging receptor to limit patient dose by limiting the surface exposed to radiations.

• Labeled A, B and C to avoid confusions between film/plate sizes (ISO 3665 – sizes 0, 1, 2, 3 & 4) and sensor sizes (internal – sizes 0, 1 & 2

5154232 Collimator - size A - 19 x 24 mm

5154240 Collimator - size B - 23 x 35 mm

5154257 Collimator - size C - 31 x 39 mm

COLLIMATOR TYPE

Format (mm) For use with digital sensor For use with film or CR

A 19 x 24 Size 0

B 23 x 35 Size 1 Size 0 22 x 35

C 31 x 39 Size 2 Size 1 24 x 40 Size 2 31 x 41

Standard cone 60 mm diameter Size 3 27 x 54 Size 4 57 x 76


Recommended