PP DRAFTING SERVICE
5 ELOUERA CLOSE, ELTHAM, 3095Tel: (03) 9439 3848
SCALE:
DATE:
DRAWN:
JOB/SHEET NO: REV:
BUILDING PRACTITIONER:-P. FILDES - Reg. No. DP-AD 1470
GENERAL NOTES
DRAWING TITLE:
CLIENT:
WORKING DRAWINGS
1. All materials and work practices shall comply with, but not limited to the Building Regulations2018, National Construction Code Series 2019 Building Code of Australia Vol 2, and all relevantcurrent Australian Standards (as amended) referred to therein.
2. Unless otherwise specified, the term BCA shall refer to National Construction Code Series 2019Building Code of Australia Volume 2.
3. All materials and construction practice shall meet the Performance Requirements of the BCA.Where a performance solution is proposed then, prior to the implementation or installation, it mustfirst be assessed and approved by the Relevant Building Surveyor as meeting the PerformanceRequirements of the BCA.
4. Glazing including safety glazing shall be installed to a size, type and thickness so as to complywith:
- BCA Part 3.6 for Class 1 and 10 buildings within a design wind speed of not morethan N3, and
- BCA Part B1.4 for Class 2 to 9 buildings
5. Waterproofing of wet areas, being bathrooms, showers, shower rooms, laundries, sanitarycompartments and the like shall be provided in accordance with AS 3740-2010: Waterproofing ofDomestic Wet Areas.
6. These Drawings shall be read in conjunction with any House Energy Rating (HER) report andshall be constructed in accordance with the stamped plans endorsed by the accredited ThermalPerformance Assessor without alteration
7.Step sizes to be:- Risers (R) 190mm maximum and 115mm minimum- Going (G) 355mm maximum and 240mm minimum- 2R + 1G = 700mm maximum and 550mm minimum- with less than 125mm gap between open treads
8. All treads, landings and the like to have a slip-resistance classification of P3 or R10 for drysurface conditions and P4 or R11 for wet surface conditions, or a nosing strip with a slip-resistanceclassification of P3 for dry surface conditions and P4 for wet surface conditions.
9. Provide barriers where change in level exceeds 1000mm above the surface beneath landings,ramps and/or treads. Barriers (other than tensioned wire barriers) to be:
- 1000mm min. above finished surface level of balconies, landings or the like, and- 865mm min. above finished surface level of stair nosing or ramp, and- vertical with less than 125mm gap between, and- any horizontal element within the balustrade between 150mm and 760mm above the
floor must not facilitate climbing where changes in level exceeds 4000mm above the surfacebeneath landings, ramps and/or treads.
Wire barrier construction to comply with NCC 2019 BCA Part 3.9.2.3 for Class 1 and10 Buildings and NCC 2019 BCA Volume 1 Part D2.16 for other Classes of Buildings
10. Top of handrails to be minimum 865mm vertically above stair nosing and floor surface oframps.
11. Window sizes nominated are nominal only. Actual size may vary according to manufacturer.Windows to be flashed all around.
12. Where the building (excludes a detached Class 10) is located in a termite prone area thebuilding is to be provided with a termite management system.
13. Concrete stumps:- up to 1400mm long* to be 100mm x 100mm (1 No. H.D. Wire)- 1401mm to 1800mm long* to be 100mm x 100mm (2 No. H.D. Wires)- 1801mm to 3000mm long* to be 125mm x 125mm (2 No. H.D. Wires)- 100mm x 100mm stumps exceeding 1200mm above ground level to be braced
where no perimeter base brickwork provided. * inc embedded length.
14. All stormwater to be taken to the legal point of discharge to the Relevant Authorities approval.
15. These drawings shall be read in conjunction with all relevant structural and all other consultantsdrawings/details and with any other written instructions issued in the course of the contract.
16. Site plan measurements in metres - all other measurements in millimetres u.n.o.
17. Figured dimensions take precedence over scaled dimensions.
18. The Builder shall take all steps necessary to ensure the stablility and general water tightness ofall new and/or existing structures during all works.
19. The Builder and Subcontractors shall check and verify all dimensions, setbacks, levels andspecifications and all other relevant documentation prior to the commencement of any works. Report alldiscrepancies to this office for clarification.
20. Installation of all services shall comply with the respective supply authority requirements.
21. The Builder and Subcontractor shall ensure that all stormwater drains, sewer pipes and the like arelocated at a sufficient distance from any buildings footing and/or slab edge beams so as to preventgeneral moisture penetration, dampness, weakening and undermining of any building and its footingsystem on this site or adjacent sites.
22. These plans have been prepared for the exclusive use by the Client of Fildes Design & Drafting P/LTrading As PP Drafting Service (The Designer) for the purpose expressly notified to the Designer. Anyother person who uses or relies on these plans without the Designer’s written consent does so at theirown risk and no responsibility is accepted by the Designer for such use and/or reliance.
23. The approval by this office of a substitute material, work practice, variation or the like is not anauthorisation for its use or a contract variation. All variations must be accepted by all parties to theagreement and where applicable the Relevant Building Surveyor prior to implementing any variation.
The Client and/or the Client’s Builder shall not modify or amend the plans without the knowledge andconsent of PP Drafting Service except where a Registered Building Surveyor makes minor necessarychanges to facilitate the Building Permit application and that such changes are promptly reported back toPP Drafting Service.
A building permit is required prior to the commencement of these works. The release of thesedocuments is conditional to the Owner obtaining the required Building Permit.
24. SD denotes location of smoke alarms to be provided and installed in accordance withA.S.3786-2014 & A.S.3786-1993 and, unless installed in an existing part of a Class 1, 2 or 3 building ora Class 4 part of a building, the smoke alarm shall be interconnected and hard wired with battery backup.
25. Lift off hinges to W.C. doors where door swings in and the jamb is within 1200mm of the closet pan.
26. denotes exhaust fansLight and ventilation to be provided in accordance with the appropriate clauses from the BCA.Light: 10% room area Ventilation: 5% room areaColorbond / metal roof construction: Exhaust fans to be vented outside.
27. Dimensions and/or conditions approved by planning permits / building consents / VCAT must not bealtered without referral to the responsible authority or building surveyor. Alterations must be approved inwriting.
28. For buildings in marine or other exposure environments shall have masonary units, mortar and allbuilt in components and the like complying with the durability requirements of Table 4.1 ofAS4773.1-2015 Masonry in small buildings, Part 1: Design.
STORMWATER90mm DIA. Class 6 UPVC stormwater line laid to a minimum grade of 1:100 and connected to the legalpoint of stormwater discharge. Provide inspection openings at 9000mm C/C and at each change ofdirection.
The cover to underground stormwater drains shall not be less than- 100mm under soil- 50mm under paved or concrete areas- 100mm under reinforced concrete or paved driveways- 75mm under reinforced concrete driveways
SITE ENVIRONMENT DESIGN INFORMATIONSite Bushfire Attack Assessment (simplified method)Refer to separate document and also BAL Rating denoted on these plans.Site ClassificationRefer to separate Soil Test Report as denoted within Engineer’s Report.Design gust wind speed / wind classificationRefer to Engineer’s Report.Climate ZoneClimate zone for thermal design / thermal performance assessment : Zone 6.Corrosion protection of built-in structural membersProvide corrosion protection of built-in structural steel members such as steel lintels, shelf angles,connectors, accessories (other than wall ties) in accordance with Table 4.1 of AS4773.1-2015 Masonryin Small Buildings Part 1:Design suitable for a Coastal Environment Classification.Corrosion protection for sheet roofingProvide corrosion protection for sheet roofing in accordance with BCA Table 3.5.1.1a suitable for aCoastal Environment Classification.
26-Jun-20 6:00:57 PMZ:\PPDRAFT\Farrell-Cape Woolamai\Farrell_Cape WoolamaiWD_RevA_30-1-20.rvt
B26 MAROUBRA DRIVE, CAPE WOOLAMAI 1489 /WD0
JAN 2020
PAF/CH
NEW EXTENSION TO EXISTING RESIDENCE
MR. P. & MRS. E. FARRELL
Sheet List
Sheet Number Sheet Name Current Revision
WD0 Cover Sheet B
WD1 Site Plan B
WD2 Demolition Ground Floor Plan B
WD3 Proposed Ground Floor Plan B
WD4 Proposed First Floor Plan B
WD5 North & West Elevations B
WD6 South & East Elevations B
WD7 Sections B
WD8 Shadow Diagrams B
WD9 Specifications B
WD10 Overlooking Site Plan B
NOTES:CONNECT NEW DOWNPIPES TO EXISTING SWD SYSTEM.
ALL DRAINAGE SHALL BE CONNECTED TO THE LEGAL POINT OFDISCHARGE AND SHALL COMPLY WITH LOCAL AUTHORITYREQUIREMENTS AND BUILDING CODE OF AUSTRALIA.· 100MM DIA UPVC STORMWATER DRAINS· MINIMUM FALL 1 IN 80 WITH 300mm MIN COVER· DOWNPIPES AT 12METRE CENTRES MAX
NEW DOWNPIPE LOCATIONS ARE APPROXIMATES ONLY ANDSHOULD BE CONFIRMED ON SITE BY A QUALIFIED PLUMBER
MAROUBRA DRIVE
174° 00' 00"37.12 m
84° 00' 00"
15.77 m
264° 00' 00"
15.77 m
354° 00' 00"37.12 m
LOT 931No. 26
1.829 EASEMENT
PROPOSEDSECONDSTOREYEXTENSION
EXISTINGCARPORT
EXISTINGSINGLESTOREY W/B.RESIDENCE
EXISTINGVERANDAH
EXISTING SINGLE STOREYW/BOARD RESIDENCE
EXISTINGVERANDAH
EXISTING DOUBLESTOREY BRICKRESIDENCE
LOT 932
LOT 930
EXISTINGSHED
NOM.
1580
NOM.
8534
NOM.
8600
HW
HW
HW
HW HW
D
NEW DP NEW DP
NEW DP NEW DP
Stormwater drainto legal point ofdischarge
PROPOSEDVERANDAHEXTENSION
PROPOSEDVERANDAHEXTENSION
SITE AREA = 585.525m²
EXISTING COVERAGE = 217.49m² 42.38%
PROPOSED SITE COVERAGE = 257.32m² 43.94%PROPERTY IS NOT WITHIN A DESIGNATED BUSHFIRE PRONE AREA
MINIMUM GARDEN AREA REQUIREMENT 35% X 585.525m² = 204.93m²PROPOSED AVAILABLE GARDEN AREA = 328.21m²
PP DRAFTING SERVICE
5 ELOUERA CLOSE, ELTHAM, 3095Tel/Fax: (03) 9439 3848
SCALE:
DATE:
DRAWN:
JOB/SHEET NO: REV:
BUILDING PRACTITIONER:-P. FILDES - Reg. No. DP-AD 1470
DRAWING TITLE:
CLIENT:
WORKING DRAWINGSAs indicated
26-Jun-20 6:00:58 PMZ:\PPDRAFT\Farrell-Cape Woolamai\Farrell_Cape WoolamaiWD_RevA_30-1-20.rvt
B26 MAROUBRA DRIVE, CAPE WOOLAMAI 1489 /WD1
JAN 2020
PAF/CH
NEW EXTENSION TO EXISTING RESIDENCE
MR. P. & MRS. E. FARRELL
N
SCALE 1 : 200
SITE ROOF PLAN
FLOOR AREAS
EXISTING RESIDENCE 140.86 m²
PROPOSED FIRST FLOOR 61.14 m²
202.00 m²
EXISTING CARPORT 34.74 m²
EXISTING DRIVEWAY 30.68 m²
EXISTING SHED 13.50 m²
EXISTING VERANDAH 28.39 m²
PROPOSED VERANDAH 9.15 m²
116.46 m²
THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHRELEVANT ENGINEERS DESIGN AND DETAILS.
BED 1 BED 2 BED 3
FAMILY
LIVING ENTRY
BATH
LDRY
WC
KITCHEN
DINING
VERANDAH
VERANDAH
CARPORT
Demolish existing roof Retain existing ceiling
Remove existingwindows
Demolish existinglinen cupboard
Make newopening
Demolish steps
Remove timberpost
Remove timberdoors
Remove Bathroom fitout.Terminate & seal services& electrical as required
PP DRAFTING SERVICE
5 ELOUERA CLOSE, ELTHAM, 3095Tel/Fax: (03) 9439 3848
SCALE:
DATE:
DRAWN:
JOB/SHEET NO: REV:
BUILDING PRACTITIONER:-P. FILDES - Reg. No. DP-AD 1470
DRAWING TITLE:
CLIENT:
WORKING DRAWINGS 1 : 100
26-Jun-20 6:00:59 PMZ:\PPDRAFT\Farrell-Cape Woolamai\Farrell_Cape WoolamaiWD_RevA_30-1-20.rvt
B26 MAROUBRA DRIVE, CAPE WOOLAMAI 1489 /WD2
JAN 2020
PAF/CH
NEW EXTENSION TO EXISTING RESIDENCE
MR. P. & MRS. E. FARRELL
SCALE 1 : 100
DEMOLITION GROUND FLOOR PLAN
N
AWD7
AWD7
BWD7
BWD7
BED 1 BED 2
FAMILY
LIVING ENTRY
BATH
LDRY
WC
KITCHEN
DINING
VERANDAH
VERANDAH
Build up existingwindow opening
CARPORT
Proposed first floorextension over
NEWSD
W10
New aluminiumwindow
50090
1100 90 1160
Pantry
New pantrycupboard
125 x 125 timberpost
125 x 125 timberpost
D8
NEW DP NEW DP
NEW DP NEW DP
Replace existingtimber doors &window withaluminium
Build upexistingopening
New tiledfloor
1975 1000 1975
500
New gasfireplace
Extend existingdeck & verandah.Roof to matchexisting dwelling
Extend existingdeck & verandah.Roof to matchexisting dwelling
New vanity basin &shower to beinstalled
THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHRELEVANT ENGINEERS DESIGN AND DETAILS.
PP DRAFTING SERVICE
5 ELOUERA CLOSE, ELTHAM, 3095Tel/Fax: (03) 9439 3848
SCALE:
DATE:
DRAWN:
JOB/SHEET NO: REV:
BUILDING PRACTITIONER:-P. FILDES - Reg. No. DP-AD 1470
DRAWING TITLE:
CLIENT:
WORKING DRAWINGS 1 : 100
26-Jun-20 6:01:00 PMZ:\PPDRAFT\Farrell-Cape Woolamai\Farrell_Cape WoolamaiWD_RevA_30-1-20.rvt
B26 MAROUBRA DRIVE, CAPE WOOLAMAI 1489 /WD3
JAN 2020
PAF/CH
NEW EXTENSION TO EXISTING RESIDENCE
MR. P. & MRS. E. FARRELL
SCALE 1 : 100
PROPOSED GROUND FLOOR PLAN
N
AWD7
AWD7
BWD7
BWD7
90
STAIRS
1910 90
ROBE
60090
BED 3
4000 90
6870
90
BED 4
3000
902480
90
BED 3
3000
90
90
BATH
2510 9060090
BED 4
3400 90
90
ROBE
2000
90910
90
RUMPUS
2480
90910
90
ROBE
2000
90
BATH
2900
90
WC
90090
NOOK
1640
90
STAIRS
2950
90
90 6190 90500
90
WC
1400 90 1020 90
BED 4
3590 90
6370
BALCONY
1200
6870 700
6370 500
D4
D1
D5
D2
D6
W4
W3
W5
W6
W7
W2
W1
BED 3
RUMPUS
BED 4BATH
WCBALCONY
ROBE
ROBE
NEWSD
Re-clad existingroof to matchextension
Extend existingverandah & re-clad roofto match dwelling roof
W9
1000 highhandrail with glassbalustrade
W8
600
D3
W12
W11
500
NOOK
1595
8840
THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHRELEVANT ENGINEERS DESIGN AND DETAILS.
PP DRAFTING SERVICE
5 ELOUERA CLOSE, ELTHAM, 3095Tel/Fax: (03) 9439 3848
SCALE:
DATE:
DRAWN:
JOB/SHEET NO: REV:
BUILDING PRACTITIONER:-P. FILDES - Reg. No. DP-AD 1470
DRAWING TITLE:
CLIENT:
WORKING DRAWINGS 1 : 100
26-Jun-20 6:01:01 PMZ:\PPDRAFT\Farrell-Cape Woolamai\Farrell_Cape WoolamaiWD_RevA_30-1-20.rvt
B26 MAROUBRA DRIVE, CAPE WOOLAMAI 1489 /WD4
JAN 2020
PAF/CH
NEW EXTENSION TO EXISTING RESIDENCE
MR. P. & MRS. E. FARRELL
SCALE 1 : 100
PROPOSED FIRST FLOOR PLAN
N
FFL
FCL
FFL
FCL
3100
NOM.
400
2700 W
2 W1
OVERALL HEIGHT
8000
WALL HEIGHT
6450
Corrugated iron roof withpitch to match existing
Aluminiumawning windows
Timber weatherboardsto match existing
W10
FFL
FCL
FFL
FCL
2700
NOM.
400
3100
W5
W4
W3
Corrugated iron roof withpitch to match existing
Aluminium double-hung windows
Timber weatherboardsto match existing
1000 highhandrail withglass balustrade
BOUNDARY FENCE
1700
9m overlooking arcsee overlookingdetails WD10
1700
1700
9m overlooking arcsee overlookingdetails WD10
BOUNDARY FENCE
1700
Replace existingtimber doors & windowwith aluminium
Extend existing deck &verandah. Roof tomatch existing dwelling
THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHRELEVANT ENGINEERS DESIGN AND DETAILS.
PP DRAFTING SERVICE
5 ELOUERA CLOSE, ELTHAM, 3095Tel/Fax: (03) 9439 3848
SCALE:
DATE:
DRAWN:
JOB/SHEET NO: REV:
BUILDING PRACTITIONER:-P. FILDES - Reg. No. DP-AD 1470
DRAWING TITLE:
CLIENT:
WORKING DRAWINGS 1 : 100
26-Jun-20 6:01:02 PMZ:\PPDRAFT\Farrell-Cape Woolamai\Farrell_Cape WoolamaiWD_RevA_30-1-20.rvt
B26 MAROUBRA DRIVE, CAPE WOOLAMAI 1489 /WD5
JAN 2020
PAF/CH
NEW EXTENSION TO EXISTING RESIDENCE
MR. P. & MRS. E. FARRELL
SCALE 1 : 100
WEST ELEVATION
SCALE 1 : 100
NORTH ELEVATION
FFL
FCL
FFL
FCL
2700
400
3100
W7
W6
OVERALL HEIGHT
8000
Corrugated iron roof withpitch to match existing
Aluminium awningwindows
Timber weatherboardsto match existing
1000 highhandrail with glassbalustrade
FFL
FCL
FFL
FCL
2700
NOM.
400
3100
Corrugated iron roof withpitch to match existing
Aluminium awningwindows
Timber weatherboardsto match existing
W9
W11
W12
W8
THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHRELEVANT ENGINEERS DESIGN AND DETAILS.
PP DRAFTING SERVICE
5 ELOUERA CLOSE, ELTHAM, 3095Tel/Fax: (03) 9439 3848
SCALE:
DATE:
DRAWN:
JOB/SHEET NO: REV:
BUILDING PRACTITIONER:-P. FILDES - Reg. No. DP-AD 1470
DRAWING TITLE:
CLIENT:
WORKING DRAWINGS 1 : 100
26-Jun-20 6:01:03 PMZ:\PPDRAFT\Farrell-Cape Woolamai\Farrell_Cape WoolamaiWD_RevA_30-1-20.rvt
B26 MAROUBRA DRIVE, CAPE WOOLAMAI 1489 /WD6
JAN 2020
PAF/CH
NEW EXTENSION TO EXISTING RESIDENCE
MR. P. & MRS. E. FARRELL
SCALE 1 : 100
EAST ELEVATION
SCALE 1 : 100
SOUTH ELEVATION
FFL
FCL
FFL
FCL
LIVING ENTRY KITCHEN DINING VERANDAH
RUMPUSWC BALCONY
Naturalground line
Existing sub-floorstructure
Colorbond custom orbroof sheeting over trussroof to manufacturer'sspecification
Upper floor joists tomanufacturer's specification
Eaves, fascia & gutter tomatch existing
NOM. 300
2700
400
3100
D11000 highhandrail with glassbalustrade
FCL
FCL
2700
NOM.
400
3100
FFL
FFL
Naturalground line
Existing sub-floorstructure
Colorbond custom orbroof sheeting over trussroof to manufacturer'sspecification
Upper floor joists tomanufacturer's specificationBATHWC
KITCHEN
NOM. 300
Eaves, fascia & gutter tomatch existing
Stair constructionRiser max 190mmGoing min 250mm900h balustradeabove nosing line
THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITHRELEVANT ENGINEERS DESIGN AND DETAILS.
PP DRAFTING SERVICE
5 ELOUERA CLOSE, ELTHAM, 3095Tel/Fax: (03) 9439 3848
SCALE:
DATE:
DRAWN:
JOB/SHEET NO: REV:
BUILDING PRACTITIONER:-P. FILDES - Reg. No. DP-AD 1470
DRAWING TITLE:
CLIENT:
WORKING DRAWINGS 1 : 100
26-Jun-20 6:01:04 PMZ:\PPDRAFT\Farrell-Cape Woolamai\Farrell_Cape WoolamaiWD_RevA_30-1-20.rvt
B26 MAROUBRA DRIVE, CAPE WOOLAMAI 1489 /WD7
JAN 2020
PAF/CH
NEW EXTENSION TO EXISTING RESIDENCE
MR. P. & MRS. E. FARRELL
SCALE 1 : 100
SECTION A-A
SCALE 1 : 100
SECTION B-B
MAROUBRA DRIVE
LOT 931No. 26
PROPOSEDSECONDSTOREYEXTENSION
EXISTINGCARPORT
EXISTINGSINGLESTOREY W/B.RESIDENCE
EXISTING SINGLE STOREYW/BOARD RESIDENCE
EXISTINGVERANDAH
EXISTING DOUBLESTOREY BRICKRESIDENCE
LOT 932
MAROUBRA DRIVE
LOT 931No. 26
PROPOSEDSECONDSTOREYEXTENSION
EXISTINGCARPORT
EXISTINGSINGLESTOREY W/B.RESIDENCE
EXISTING SINGLE STOREYW/BOARD RESIDENCE
EXISTINGVERANDAH
EXISTING DOUBLESTOREY BRICKRESIDENCE
LOT 932
MAROUBRA DRIVE
LOT 931No. 26
PROPOSEDSECONDSTOREYEXTENSION
EXISTINGCARPORT
EXISTINGSINGLESTOREY W/B.RESIDENCE
EXISTING SINGLE STOREYW/BOARD RESIDENCE
EXISTINGVERANDAH
EXISTING DOUBLESTOREY BRICKRESIDENCE
LOT 932
PP DRAFTING SERVICE
5 ELOUERA CLOSE, ELTHAM, 3095Tel/Fax: (03) 9439 3848
SCALE:
DATE:
DRAWN:
JOB/SHEET NO: REV:
BUILDING PRACTITIONER:-P. FILDES - Reg. No. DP-AD 1470
DRAWING TITLE:
CLIENT:
WORKING DRAWINGS1 : 250
26-Jun-20 6:01:12 PMZ:\PPDRAFT\Farrell-Cape Woolamai\Farrell_Cape WoolamaiWD_RevA_30-1-20.rvt
B26 MAROUBRA DRIVE, CAPE WOOLAMAI 1489 /WD8
JAN 2020
Author
NEW EXTENSION TO EXISTING RESIDENCE
MR. P. & MRS. E. FARRELL
SCALE 1 : 250
SHADOW DIAGRAM 9AM EQUINOXSCALE 1 : 250
SHADOW DIAGRAM 12PM EQUINOX
SCALE 1 : 250
SHADOW DIAGRAM 3PM EQUINOX
N
LIGHTINGMax. 5W / m² required in new internal areas.4W / m² on decking, balconies, alfresco and verandah.3W / m² for garages and carports.
Owner or Builder to provide the Relevant Building Surveyorwith Lighting Plan for compliance purposes.
Note: Smoke detectors to be locatedin hallways adjacent to bedroomsdoors as per General Note 24
PP DRAFTING SERVICE
5 ELOUERA CLOSE, ELTHAM, 3095Tel/Fax: (03) 9439 3848
SCALE:
DATE:
DRAWN:
JOB/SHEET NO: REV:
BUILDING PRACTITIONER:-P. FILDES - Reg. No. DP-AD 1470
DRAWING TITLE:
CLIENT:
WORKING DRAWINGS 1 : 100
26-Jun-20 6:01:12 PMZ:\PPDRAFT\Farrell-Cape Woolamai\Farrell_Cape WoolamaiWD_RevA_30-1-20.rvt
B26 MAROUBRA DRIVE, CAPE WOOLAMAI 1489 /WD9
JAN 2020
PAF/CH
NEW EXTENSION TO EXISTING RESIDENCE
MR. P. & MRS. E. FARRELL
WINDOW SCHEDULE
Window No Height Width LocationFrame
Construction Operation Glazing Type1 2000 600 Stairs Aluminium Fixed Double Glazed
2 500 2200 Bed 3 Aluminium Double Glazed
3 1500 2400 Bed 3 Aluminium Double Hung Double Glazed
4 2100 1800 Rumpus Aluminium Skiding Door Double Glazed
5 1500 2400 Bed 4 Aluminium Double Hung Double Glazed
6 500 2200 Bed 4 Aluminium Double Glazed
7 800 1500 Bath Aluminium Awning Double Glazed
8 600 400 WC Aluminium Awning Double Glazed
9 800 1500 Bath Aluminium Awning Double Glazed
10 1600 1100 Bed 2 Aluminium Double Hung Double Glazed
11 800 1500 Stairs Aluminium Awning Double Glazed
12 600 400 Nook Aluminium Awning Double Glazed
TIMBER FRAMING SPECIFICATION
Member Size StressGrade
Max.Spacing
Max. Span Remarks
Top Plates 2/90 x 45
F5 mgp10 450 UntrenchedBottom Plates 90 x 45
F5 mgp10 450 Untrenched
CommonStuds
70 x 35
F5 mgp 10 450 2700 Solid Nogging at 1200 cts. max.
Solid Nogging at 1200 cts. max.
Jamb Studs 90 x 45 F5 mgp 10 3000
Lintels
Noggins Merch 1350
Bracing Metal angle - As per AS1684
Rafters
RoofTrusses
Refer to Manufacturer's Design
All timber framing to comply with AS1684.4All concrete footings to comply with AS 2870All masonry to comply with AS 3700All glazing to comply with AS 1288-2006
Strip footings and pad to be founded on weathered siltstonerock in accordance with a class A site as per soil report
19mm thick structural graded particleboard22mm thick tongue and groove strip hardwood flooring
Flooring
Refer to Engineer's Computations
90 x 35
Upper FloorJoists
Refer to Engineer's Computations
NOTESee soil test reportSee engineer's comps & drawings for all structural details
Stumps 100 x 100 concreteStumps set on 300 x 300 x 150 concrete pad footings.Provide bracing to stumps exceeding 1200 in height above ground level. Provide caps to top of stumps in accordance with the BCA.
1400 1800
Deck FloorJoists
90 x 45 F7 KD Treated Pine @ 450ctrs continuous over 2 spans min
Floor Joists 90 x 45
F17 (HW) 1400Bearers 90 x 70
1800F17 (HW)
1800
450
Studssupporting firstfloor framing
90 x 45 F5 mgp 10 450 Solid Nogging at 1200 cts. max.
Deck Bearers 2/90 x 45 F7 KD Treated Pine @ 1500ctrs continuous over 2 spans min
Deck Stumps 100 x 100 concreteSupporting floor only at 1500ctrs max.300 x 300 x 200mm min or 300dia x 200mm min concrete pad footings.
Refer to Engineer's Computations
DOOR SCHEDULE
Door No Height Width Location Opening TypeDoor
ConstructionD1 2040 820 Bed 3 Swing Internal Hollow Core
D2 2100 820 Bed 3 2 Panel Robe sliding Internal Hollow Core
D3 2040 720 WC Single Cavity Sliding Internal Hollow Core
D4 2040 720 Bath Single Cavity Sliding Internal Hollow Core
D5 2040 820 Bed 4 Swing Internal Hollow Core
D6 2100 820 Bed 4 2 Panel Robe sliding Internal Hollow Core
D8 2040 720 Stairs Single Cavity Sliding Internal Hollow Core
MAROUBRA DRIVE
174° 00' 00"37.12 m
84° 00' 00"
15.77 m
264° 00' 00"
15.77 m
354° 00' 00"37.12 m
LOT 931No. 26
1.829 EASEMENT
PROPOSEDSECONDSTOREYEXTENSION
EXISTINGCARPORT
EXISTINGSINGLESTOREY W/B.RESIDENCE
EXISTINGVERANDAH
EXISTING SINGLE STOREYW/BOARD RESIDENCE
EXISTINGVERANDAH
EXISTING DOUBLESTOREY BRICKRESIDENCE
LOT 932
LOT 930
EXISTINGSHED
1580
8534 8600
No overlookingwindow 1.7mabove floor
No overlookingwindow 1.7mabove floor
9m overlooking arcsee NorthElevation WD5
9m overlooking arcsee NorthElevation WD5
PP DRAFTING SERVICE
5 ELOUERA CLOSE, ELTHAM, 3095Tel/Fax: (03) 9439 3848
SCALE:
DATE:
DRAWN:
JOB/SHEET NO: REV:
BUILDING PRACTITIONER:-P. FILDES - Reg. No. DP-AD 1470
DRAWING TITLE:
CLIENT:
WORKING DRAWINGS 1 : 200
26-Jun-20 6:01:13 PMZ:\PPDRAFT\Farrell-Cape Woolamai\Farrell_Cape WoolamaiWD_RevA_30-1-20.rvt
B26 MAROUBRA DRIVE, CAPE WOOLAMAI 1489 /WD10
JAN 2020
PAF/CH
NEW EXTENSION TO EXISTING RESIDENCE
MR. P. & MRS. E. FARRELL
SCALE 1 : 200
OVERLOOKING SITE PLAN
N