20
Flight 60 The Most Versatile Autonomous Ventilato 1 Confidential
Transcript
Page 1: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

1

Flight 60The Most Versatile

Autonomous Ventilator

Confidential

Page 2: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

2

Performance• Volume Guarantee, Weaning mode • Bi-Phasic Ventilation (APRV)• Unlimited autonomy: 12 Hours battery life, 15lbs

Well known technology in an intuitive and

advanced ventilator

Confidential

Page 3: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

3

Versatility• Paediatric to Adults• Dual/Single limb• High Pressure & Low Flow Oxygen• Invasive and non invasive

Well known technology in an intuitive and

advanced ventilator

Confidential

Page 4: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

4

Simplicity• High resolution 7” touch screen• Ease of use/ All functions on one screen• Waveforms, loops and 72 Hours trends

Well known technology in an intuitive and

advanced ventilator

Confidential

Page 5: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

5

Simplicity• High resolution 7” touch screen• Ease of use/ All functions on one screen• Waveforms, loops and 72 Hours trends

Well known technology in an intuitive and

advanced ventilatorPerformance

• Volume Guarantee, Weaning mode • Bi-Phasic Ventilation (APRV)• Unlimited autonomy: 12 Hours battery life, 15lbs

Versatility• Paediatric to Adults• Dual/Single limb• High Pressure & Low Flow Oxygen• Invasive and non invasive

Confidential

Page 6: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

6

99% Success, meet all clinical needsTrauma

COPD

ARDS

NeuromuscularALS

Pulmonary Edema

Spinal Cord Injury

Lung Cancer

Confidential

Page 7: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

7

Flight 60 – Unique Features for Transport, Sub-Acute, ED, LTAC, Home Care & ICU*

(*emerging markets)

Confidential

Page 8: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

8

Bright DisplayLoops &

Waveforms

Advanced Monitoring

Lung Mechanics

Hospital StandardInternal Blender

Compact and Easy to Use

15lbs

Advanced ModesMVG

Bi-Level/APRVPRVC

Supreme SafetyExhaled Volume

Monitoring

Extended VersatilityDual Limb Model

Confidential

Page 9: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

9

Flight 60 – Meets the Need

• APRV (transport ARDS patients , maintain ICU settings)• Internal Blender (durability)• Quick-Start• Lightweight 15lbs

In-Hospital Transport

• Quick-Start• VCV from 30ml to 2,200• All modes• Waveforms and Loop

Sub-Acute

• Advanced Modes• Dual Limb• Internal Blender• Lung Mechanics

Long Term• 12 Hours battery• Telemedicine ready• Integrated O2 sensor with in-use calibration• Volume Guarantee

Home Care

Confidential

Page 10: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

10

HT70+ PhilipsV60

Hamilton C2

Trilogy 100/20

0Vela Flight

60 Market Segment

+ + + Sub-Acute

+ + Transport

+ Acute Care NIV

+ + + + Long Term

+ + + Home Care

+ + + ICU(emerging markets)

Page 11: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

11

Flight 60 – Unique Weaning Mode 1/3

Volume Guarantee Mode

Improves patient ventilation and safety by adjusting to changes in:• Progression of the disease• Body position and sleep stages

• Best of volume control ventilation and pressure control ventilation.

Confidential

Page 12: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

12

Flight 60 – Unique Weaning Mode 2/3

MVG – Minute Volume Guarantee

MVG = Volume Guarantee + Back-up rate

• Improved Patient Comfort• Adaptive PSV (Lower PIP for equal Volume)• Better Weaning (automatically switches to

spontaneous breathing)

Confidential

Page 13: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

13

Flight 60 – Unique Weaning Mode 3/3

Unique Trigger Delay function

• Encourages spontaneous breathes • Eliminates frequent switching between patient triggered/time

triggered breathes

• Improved weaning & enhanced patient synchronization

Confidential

Page 14: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

14

MVG Improves Patient ComfortCase Report

• Patient and history:– A 48 year old man with history of Crohn’s disease

and epilepsy was admitted with pleuritic chest pain and food aspiration. Patient was sedated and orally intubated.

• Initial vent Settings:– Mode: SIMV-PC, PC = 15cmH2O, PEEP = 7cmH2O

• MVG Setting:– Mode: MVG, Target Volume = 400ml, PEEP = 7cmH2O

Confidential

Page 15: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

15

MVG Improves Patient Comfort Case Report

Confidential

Phase 1: SIMV Mode Phase 1: MVG Mode

PIP = 27cmH2OVt = 454ml

PIP = 17cmH2OVt = 437ml

MVG is able to track the patient’s change in respiratory mechanics and adjust pressure accordingly.

Page 16: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

16

Flight 60 – Flight 60 –Low maintenance and Reliability

• Install base of over 2000 in 3 years• Only Manifold and O2 sensor are replaced on

preventive maintenance• Manifold PM is at 15,000 working hours

Confidential

Page 17: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

17

1500 beds, 40 F60s, 100% satisfaction

• Successfully integrated into 10 sub-acute wards• Adapted by ER staff as main ventilator• In-hospital transport – Only Flight 60• Replaced Vela and iVent201• 3 Years of experience

Leading acute care university hospital

Confidential

Page 18: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

18

Active mobilization with Flight 60

• “...it’s the smallest that they make but at the same time the electronics allow us to do all of the types of therapy we do with a full size ventilator…”

Bedside: PB840Transport: Flight 60

Stephen Holland, M.D.Vice President and Chief Medical Officer

Confidential

Page 19: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in
Page 20: [PPT]PowerPoint Presentation - Flight · Web viewVersatility Paediatric to Adults Dual/Single limb High Pressure & Low Flow Oxygen Invasive and non invasive Well known technology in

www.flight-medical.com


Recommended