26
Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division Brookhaven National Laboratory, Upton, NY 11973 17 th International Magnetic Measurement Workshop (IMMW17) Barcelona, Spain, 18-23 September, 2011 * Work supported by the U.S. Department of Energy under contract DE-AC02-98CH10886
Transcript
Page 1: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Precision Alignment of Multipoleson a Girder for NSLS-II*

Animesh JainSuperconducting Magnet Division

Brookhaven National Laboratory, Upton, NY 11973

17th International Magnetic Measurement Workshop (IMMW17)Barcelona, Spain, 18-23 September, 2011

* Work supported by the U.S. Department of Energyunder contract DE-AC02-98CH10886

Page 2: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

1

Acknowledgements

G. Aparicio, J. Cintorino, T. Dilgen, S. Dimaiuta, L. Doom,

J. Duff, J. Escallier, M. Fulkerson, G. Ganetis,

P. He, J. Hoogsteden, R. Hubbard, P. Joshi, F. Karl,

R. Loffredo, W. Louie, A. Marone, J. McCaffrey, D. Oldham,

S. Ozaki, P. Ribaudo, A. Sauerwald, S. Seiler, S. Sharma,

J. Skaritka, C. Spataro, D. Sullivan, W. Themann,

P. Wanderer, F. Willeke, C. Yu

Page 3: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

2

Introduction• The National Synchrotron Light Source-II (NSLS-II) is a new

light source presently under construction at Brookhaven National Laboratory (BNL).

• The magnets needed for the storage ring of NSLS-II are currently being produced by various manufacturers located around the world (7 vendors in 6 countries, 4 continents).

• The multipole magnets (quadrupoles and sextupoles) in the storage ring must be aligned to each other within tight tolerances (better than 30 microns).

• This talk describes the alignment procedure being followed for the multipoles in NSLS-II, and the current status of this work.

Page 4: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

3

Lattice Layout

• The storage ring consists of 30 cells, each containing six girders with one or more magnets mounted on each girder.

• Three of the girders in each cell contain either 6 or 7 multipole magnets, along with two slow orbit correctors, on each girder.

• The multipoles on a common girder need to be aligned to each other to better than ±30 microns. This is difficult to achieve by survey alone.

• The girder-to-girder alignment needs to be better than ±100 microns, and is achievable by survey.

Typical Even Cell

Typical Odd CellDipoles

Multipole girders Beam Direction

Page 5: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

4

List of Magnets in NSLS-II Storage RingShort Name Description Quantity Vendor Integ. Strength(1)

Q66A 66 mm Single Coil Short Quadrupole 30 A 2.75 TeslaQ66B 66 mm Single Coil Short "Wide" Quadrupole 30 A 2.75 TeslaQ66C 66 mm Double Coil Long Quadrupole 30 A 8.80 TeslaQ66C' 66 mm Double Coil Long Quadrupole (Kinked) 30 A 8.80 TeslaQ66D 66 mm Double Coil Short Quadrupole 90 B 5.50 TeslaQ66E 66 mm Double Coil Short "Wide" Quadrupole 30 B 5.50 TeslaQ90 90 mm Aperture Quadrupole 60 C 3.79 TeslaS76 76 mm Aperture Sextupole 30 C 100 Tesla/mS68 68 mm Aperture Sextupole 165 D 80 Tesla/m

S68W 68 mm Aperture "Wide" Sextupole 75 E 80 Tesla/mD35 35 mm Aperture Bending Dipole 54 C 1.048 Tesla.mD90 90 mm Aperture Bending Dipole 6 C 1.048 Tesla.mC100 100 mm Aperture Dipole Correctors 90 F 0.0082 T.mC101 100 mm Aperture Correctors with Skew Quad 30 F 0.086 Tesla(2)

C156 156 mm Aperture Correctors 60 F 0.0082 T.m (VF)0.0092 T.m (HF)

Fast Orbit Correctors 60 GTotal number of magnets in storage ring = 870

(1) Integrated strength is defined as Int(B.dl) for dipoles, Int(B'.dl) for quads, and Int(B".dl) for sextupoles(2) Strength listed is of the skew quadrupole; the dipole correctors have the same strengths as in C100

Page 6: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

5

Magnets on Girders in NSLS-II

Q66D

S68

Q66CS68

S68

Q66D

G2-Odd Cell

Beam Direction

C100

3.8 m

C100

Page 7: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

6

Magnets on Girders in NSLS-II

Q66D

S68

Q66C

S68

S68

Q66D

G2-Even Cell

Beam Direction

C101

3.9 m

C156

Page 8: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

7

Magnets on Girders in NSLS-IIQ66B

S68

Q90

Q90

S76

S68W

Q66A

C156

G4-Odd Cell

Fast Corr.

Beam Direction

C101

4.93 m

Page 9: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

8

Magnets on Girders in NSLS-IIQ66B

S68

Q90

Q90

S76

S68W

Q66AC156

G4-Even Cell

Fast Corr.

Beam Direction

C100

4.93 m

Page 10: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

9

Magnets on Girders in NSLS-II

Q66C’S68W

S68W

Q66D

C156

G6-Odd Cell

FastCorrector

Beam Direction

C100

S68

Q66E

3.893 m

Page 11: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

10

Magnets on Girders in NSLS-II

Q66C’

S68

S68W

Q66D

C100

G6-Even Cell

FastCorrector

Beam Direction

C100

S68

Q66E

3.9 m

Page 12: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

11

The Vibrating Wire Technique: Basics

• An AC current is passed through a wire stretched axially in the magnet.• Any transverse field at the wire location exerts a periodic force on the wire,

thus exciting vibrations.• The vibrations are enhanced if the driving frequency is close to one of the

resonant frequencies, giving high sensitivity. • The vibration amplitudes are studied as a function of wire offset to determine

the transverse field profile, from which the magnetic axis can be derived.• Resonant mode must be chosen carefully to match magnet axial position.

X-YStage

X-YStage

X Y

Weight

Wire carryingsinusoidal current

MagnetMover

Magnet

WireVibrationSensors

Page 13: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

12

Steps Involved in Alignment• Prealign the magnets on a girder using survey. Set the roll angles.• Split the magnets, install and align the vacuum chamber.• Move girder to temperature controlled test room and allow to stabilize.• Determine magnetic axis of all elements on the girder relative to the wire frame.• Pick a “best fit” line and move all magnets to this line.• Secure magnets to the girder (270 N.m) without disturbing the alignment.• Verify alignment after securing the magnets.• Characterize the magnet and girder positions, including the vertical profile of the

girder, in space using survey. (Ten tracker positions are used to get <±10 μm.)• Realign the vacuum chamber, if necessary.• Install the girder in the machine using survey data taken in the alignment stand,

and reproduce the girder profile.

Page 14: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

13

Salient Features of the Vibrating Wire System• Temperature controlled environment (±0.05 C)• Aerotech ATS03005 stages for wire movement

(0.1 micron resolution; 2.5 micron over 25 mm accuracy).• Wire ends are defined by stainless steel V-notches.• Set of 7 fiducials on each V-notch holder to locate the notches.• A pair of X-Y wire vibration sensors at each end of the wire.

Allows two independent, simultaneous measurements for data verification and redundancy.

• Fully automated acquisition and analysis software with scriptingsupport for flexibility in experiment control. Standard scripts are being developed for each girder type, as we go along.

Page 15: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

14

Wire End Support (V-notch)

Fiducials relate the wire ends to the overall girder coordinate system.

Stainless V-notch

Fiducialnests (7)

Holes to help locate the notch relative to fiducials

A V-notch with radius much smaller than the wire was chosen. The wire position is thus insensitive to the actual radius of the V-notch.

Page 16: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

15

Wire Vibration Sensors

As the wire is moved horizontally or vertically, the position of the wire relative to the sensor changes slightly (~ a few microns) due to imperfections in the stage motion. This causes a change in the operating point of the sensor.An automated piezo stage was added to keep the wire “centered” in the sensors during a scan.

Coarse manual adjustment in orthogonal axis

X-Sensor

Fine, automated adjustment along measurement axis using piezo stages

Y-Sensor

The wire motion sensors are inexpensive photointerrupters(Model GP1S094HCZ0F)

A pair of sensors is located on both ends of the wire, thus allowing two simultaneous measurements.

Page 17: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

16

Complete Wire Mover AssemblyCamera to ensure wire is correctly seated in the notch

Light Shades to reduce noise from stray light

V-notch holder with fiducials

A similar assembly is present at the other end of the wire, except that the pulley and weight are replaced by a fixed wire end.

Page 18: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

17

A Girder Under Test

Page 19: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

18

Moving Magnets to Desired Position• Each magnet sits on a thick base plate, mounted to the girder using four bolts.• A set of four vertical displacement sensors (DVRTs) is attached to the four

corners of the base plate. These allow monitoring of the vertical position, and also help in controlling roll and pitch of the magnet.

• One horizontal displacement sensor is also mounted to the base plate. This does not allow monitoring of yaw. The yaw is maintained by yaw preventers present in a temporary fixture on the girder. (Ideally, sensor should be located at midplane.)

• The displacement sensors are initialized to the magnet position relative to the chosen “best-fit” line, based on vibrating wire measurements. The vertical and horizontal positions of one selected magnet at a time are displayed in real time on large monitor screens on the walls on both sides of the girder.

• Magnets are moved manually using mounting nuts for the vertical adjustment and a pair of adjustment screws in the temporary fixture for horizontal adjustment. This has to be done in small torque increments and in small moves at a time.

Page 20: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

19

Adjusting Magnet Position

Display of Magnet Position

Vertical MovesVertical Moves

DVRTDVRT

Horizontal Moves

DVRTDVRT

Yaw Yaw PreventerPreventer

Page 21: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

20

Alignment Example: Prealigned GirderGirder 6, Cell 24; after pre-alignment and loosening

all top nuts on all magnets (Move 0)

-0.140-0.120-0.100-0.080-0.060-0.040-0.0200.0000.0200.0400.060

1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5Magnet Axial Position (m)

Hor

iz. O

ffse

t (m

m)

Chosen “best-fit” line

Page 22: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

21

Girder 6, Cell 24; after pre-alignment and loosening all top nuts on all magnets (Move 0)

-0.100

-0.050

0.000

0.050

0.100

0.150

0.200

1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5Magnet Axial Position (m)

Ver

tical

Offs

et (m

m)

Alignment Example: Prealigned Girder

Chosen “best-fit” line

Page 23: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

22

Girder 6, Cell 24; after final magnet moves (Move 3)

-0.140

-0.120

-0.100

-0.080

-0.060

-0.040

-0.020

0.000

1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5Magnet Axial Position (m)

Hor

iz. O

ffse

t (m

m)

Alignment Example: Final Alignment

Final “best-fit” line

Maximum offset = 7 micronsAverage offset = 3 micronsGoal < 10 microns (1/3 of tolerance)

Measured with two different modes.

Page 24: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

23

Girder 6, Cell 24; after final magnet moves (Move 3)

-0.050

0.000

0.050

0.100

0.150

1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5Magnet Axial Position (m)

Ver

tical

Offs

et (m

m)

Alignment Example: Final Alignment

Final “best-fit” line

Maximum offset = 6 micronsAverage offset = 3 micronsGoal < 10 microns (1/3 of tolerance)

Measured with two different modes.

Page 25: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

24

Difficulties Encountered• So far, the alignment process has not been as smooth as expected.• There are some measurement related issues:

– Sometimes noisy data. Precise reason not known, but mostly at low fields.– Sensitivity of sextupole center to small errors in the data points.– Many more data points need to be taken to allow discarding of bad data, if

needed, and still be left with enough data to get reliable center.(At present, 6 positions are measured for quads, 11 positions for sextupoles.)

– Measurement time too long (~1.5 hrs per quad, ~2 hrs per sextupole).• There are some issues with the magnet move process:

– DVRTs are not always a reliable indicator of the magnet position due to their locations far away from the magnet midplane (sensitive to roll/yaw/pitch).

– High torque of 270 N.m can potentially bend the base plate, causing DVRTsto change without a real change in the magnet position.

– Typical accuracy of magnet move is ~10 microns, which is sufficient, but we often encounter surprises exceeding 20 microns, requiring multiple moves.

Page 26: Precision Alignment of Multipoles on a Girder for NSLS-II* · 2011-09-19 · Precision Alignment of Multipoles on a Girder for NSLS-II* Animesh Jain Superconducting Magnet Division

Alignment of NSLS-II Multipoles: Animesh Jain, BNLIMMW17: September 18-23, 2011

25

Summary & Status• The alignment requirements for NSLS-II are challenging, and a

state-of-the-art vibrating wire system is now in operation to meet this challenge.

• Two simultaneous measurements, and plenty of redundant data ensure the measured centers are accurate to < ±5 microns.

• Magnets are aligned on the test bench to better than10 microns, allowing for girder profiling uncertainty, etc., inorder to comfortably meet the final tolerance of 30 microns.

• The process of moving, and in particular, securing the magnets, is quite an art, and is still being perfected. Other measurement issues are also being worked on.

• We have completed alignment in four girders so far (out of 90).