+ All Categories
Home > Documents > Precision lead screws in lab automation equipment Precision lead screws in lab automation equipment...

Precision lead screws in lab automation equipment Precision lead screws in lab automation equipment...

Date post: 07-May-2018
Category:
Upload: ngodieu
View: 218 times
Download: 1 times
Share this document with a friend
8
TM Precision lead screws in lab automation equipment Test tube fillers Chemical transfer applications Assembly and preparation systems Auto sampling Fluid handling Multi-channel pipetting
Transcript
Page 1: Precision lead screws in lab automation equipment Precision lead screws in lab automation equipment • Test tube fillers • Chemical transfer applications • Assembly and preparation

TM

Precision lead screws in

lab automation equipment

• Test tube fillers

• Chemical transfer applications

• Assembly and preparation systems

• Auto sampling

• Fluid handling

• Multi-channel pipetting

Page 2: Precision lead screws in lab automation equipment Precision lead screws in lab automation equipment • Test tube fillers • Chemical transfer applications • Assembly and preparation

Lead Screw Assemblies

TM

23200 Commerce Park, Beachwood, Ohio 44122 | phone: (216) 485-2232 | toll free: (855) 435-4958 | fax: (855) 444-7543 | helixlinear.com

End Machining• Standard End

Configurations

• Custom Turned Ends

• Custom Milled Ends

Nut Styles• Standard Nuts

- Flanged Mount - Thread Mount

•Custom Nuts

•Custom Materials

Screw Materials• Stainless Steel

• Aluminum

•Titanium

• Alloy Steel

• Low Carbon Steel

Coatings•PTFE

•Chrome

•Nickel

•Melonite

•Armalloy

Page 3: Precision lead screws in lab automation equipment Precision lead screws in lab automation equipment • Test tube fillers • Chemical transfer applications • Assembly and preparation

Testing & Validation

TM

Lead Accuracy•PØ8 (± 0.0003”/Inch)

• Laser Lead Accuracy Test Machine – ± 0.000001” Accuracy

Efficiency Measurement • Measure Screw Assembly

Efficiency

Torque Measurement•Application Specific Testing

• Torque Comparisons of Lubricants

Tensile Testing• Dynamic Loads

•Static Loads

•Stress vs. Displacement

•Capacity up to 10,000 lbs.

Thread Form Validation • CNC Thread Profile

Measurement – ± 0.00001”

Functional Testing •Life Testing

•Backlash

Dimensional Inspection •Laser Profile Inspecting

23200 Commerce Park, Beachwood, Ohio 44122 | phone: (216) 485-2232 | toll free: (855) 435-4958 | fax: (855) 444-7543 | helixlinear.com

Page 4: Precision lead screws in lab automation equipment Precision lead screws in lab automation equipment • Test tube fillers • Chemical transfer applications • Assembly and preparation

End Machining

TM

Standard end types

23200 Commerce Park, Beachwood, Ohio 44122 | phone: (216) 485-2232 | toll free: (855) 435-4958 | fax: (855) 444-7543 | helixlinear.com

Single Bearing Drive End with Keyway

Single Bearing Drive End

Single Bearing Support End

Double Bearing Drive End Double Flat

Threaded Counter-bore

Single Journal Hexagonal Drive End O.D. V-Thread

Page 5: Precision lead screws in lab automation equipment Precision lead screws in lab automation equipment • Test tube fillers • Chemical transfer applications • Assembly and preparation

Applications

TM

Multi-channel Pipetting u

t���Auto Sampling

���Lab Automation Modules q

p���Fluid Handling

23200 Commerce Park, Beachwood, Ohio 44122 | phone: (216) 485-2232 | toll free: (855) 435-4958 | fax: (855) 444-7543 | helixlinear.com

Page 6: Precision lead screws in lab automation equipment Precision lead screws in lab automation equipment • Test tube fillers • Chemical transfer applications • Assembly and preparation

Standard Nut Materials

TM

Helix Bronze•Tensile Yield: 50,000 PSI

•Tensile Ultimate: 65,000 psi

•Hardness HB 75

• Dynamic Coefficient of Friction 0.125 with Helix Lubricant

Helix Blue®

•Material: Helix™ Acetal/PTFE Blend

•Tensile Strength @ 70°F: 16,000 PSI

•PV Limit: 2,700 Lubricated

•Coefficient of Friction: 0.10 Lubricated

Helix Black®

•Material: Helix™ Acetal/PTFE Blend

•Tensile Strength @ 70°F: 16,000 PSI

•PV Limit: 2,700 Lubricated

•Coefficient of Friction: 0.10 Lubricated

•Anti-Static Properties

Helix White®

•Material: Helix™ Acetal/PTFE Blend

•Tensile Strength @ 70°F: 16,000 PSI

•PV Limit: 2,700 Lubricated

•Coefficient of Friction: 0.10 Lubricated

•Medical Grade Plastic

•Certified Ingredients (UL, FDA)

23200 Commerce Park, Beachwood, Ohio 44122 | phone: (216) 485-2232 | toll free: (855) 435-4958 | fax: (855) 444-7543 | helixlinear.com

Page 7: Precision lead screws in lab automation equipment Precision lead screws in lab automation equipment • Test tube fillers • Chemical transfer applications • Assembly and preparation

Custom Nuts

TM

Custom Molded Nuts •High Volume Molded Nuts

•Standard Helix Polymers

•Customer Specific Polymers

•Insert Molding

Custom Machined Nuts•Complex Designs that can not be Molded

•Quick Turnaround

•Standard Custom Materials

Custom Anti-Backlash Nut Designs • Anti-Backlash Feature Incorporated into your Part

• Several Anti-Backlash Designs Available to Use in your Part

23200 Commerce Park, Beachwood, Ohio 44122 | phone: (216) 485-2232 | toll free: (855) 435-4958 | fax: (855) 444-7543 | helixlinear.com

NOTE: We will 3D print your custom nut design for free.

Page 8: Precision lead screws in lab automation equipment Precision lead screws in lab automation equipment • Test tube fillers • Chemical transfer applications • Assembly and preparation

TM

23200 Commerce Park, Beachwood, Ohio 44122

phone: (216) 485-2232 | toll free: (855) 435-4958 | fax: (855) 444-7543

If you have a drawing or 3D model that you would like to have us quote, simply email it to:

[email protected]


Recommended