+ All Categories
Home > Documents > Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling...

Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling...

Date post: 03-Jul-2020
Category:
Upload: others
View: 1 times
Download: 0 times
Share this document with a friend
31
#PIWorld ©2019 OSIsoft, LLC Predictive Analytics for Reliable High Power Performance Katy Cope & Sandeep Chugh 1
Transcript
Page 1: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

Predictive Analytics for Reliable High Power Performance

Katy Cope & Sandeep Chugh

1

Page 2: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

WHO IS ECOLAB?

2

Page 3: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

Ecolab is the global leader in water, hygiene and energy technologies and services

PROVIDING AND PROTECTING WHAT IS VITAL

Every day, we work to make the world cleaner, safer and healthier

3

Page 4: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

4

HEALTHCARE / INFECTION

PREVENTION

FOOD AND

BEVERAGE

PROCESSING

LIGHT INDUSTRY

HEAVY

INDUSTRY

FOOD SERVICE AND

LODGING

ENERGY

SERVICES

WATER MANAGEMENT

HYGIENE AND ANTIMICROBIAL TECHNOLOGIES

DISPENSING AND MONITORING

GLOBAL FIELD TEAMS

Core Capabilities Across All Industries

ADVANCED ANALYTICS

Page 5: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

THE CHALLENGE

5

Page 6: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

Keeping the CONDENSER at design performance:

minimizes

fuel costs & environmental impact

maximizes

profitability &

SURFACE CONDENSERS

are the heart of your production efficiency

1″ of increased condenser backpressure

1% increase in energy use for combined cycle plants

$700K per year in fuel cost savings

Page 7: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

Control

3D TRASAR™ Technology

Remote monitoring

Collecting data

Optimized Performance

of Cooling Tower

Prevent

Real-time interpretation

Predictive analytics

Prevent upsets

Optimized Performance

of Production Asset

Optimize

Digital Twin

Machine learning

“Smart” control

Automated Optimization

of Complete Water System

Enterprise-Wide Optimization

STRATEGIC Digital Transformation

UTILITY-FOCUSED PROCESS-FOCUSED

Page 8: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

SUCCESS IMPERATIVES

24/7

Response

On-site

Expertise

Predictive

Analytics

Real-time

Monitoring

Secure

Networks

Page 9: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

Real-time

Monitoring

Connected Power Leads to Reliable High Performance

Pre-

Treatment

Cooling Tower

Post-Treatment

Boiler

Water In Wastewater Out

Condenser

Page 10: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

Secure

Networks

Built through a partnership

to deliver secure, intelligent and scalable

solutions to minimize water, maximize results and optimize total cost of operations

Working together

of global leaders

Innovative

Chemistry /

Equipment

Actionable

Insights

World Class

Service

Azure &

PowerBI Field

Service

O365 &

Software Security

G360

Sales &

Service

OIP /

Cumulus

Analytics

/ Insights

Asset

Mgmt

Trends &

Strategy

IoT +

Analytics

Portal /

Setup Integration CRM

Clean Water Safe Food Abundant

Energy

Healthy

Environments

Azure

Friendly Security

+ +

Page 11: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

Predictive

Analytics

OMNI Analytics

Predictive Indication of:

Scaling Conditions Microbial Fouling

Identification of:

Air Inleakage Macrofouling

Tube Leaks

Low CW Flow

High CW Temp

Misc Issues:

Sensor Error

Operational Limits

Rapid Trend Changes

Design Limits

Page 12: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

Predictive

Analytics

Predicting Scaling

March – Data modeling

predicts formation of

scaling in condenser

May – KPI analysis

shows scale formation

beginning in

condenser

Aug – Scale formation

discovered during

customer inspection

Page 13: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

System Assurance Center

24/7

Response

Page 14: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

ECOLAB3D Dashboard

Enterprise Performance

24/7

Response

Page 15: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

ECOLAB3D Dashboard

Site Performance

24/7

Response

Page 16: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

ECOLAB3D Dashboard

Value Delivered

24/7

Response

Page 17: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

On-site

Expertise

The Machine + Human Factor

Technology can bring “personalized service” to a whole new level

Where technology “does the work” and where the human being provides “essential expertise”

Data and AI are breadcrumbs that speed analysis

Enables a better, faster, smarter field team

VALUE

INSIGHT

PREVENTION ANALYSIS

Page 18: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

HOW OMNI ANALYTICS WORKS

18

Page 19: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

OMNITM CONDENSER PERFORMANCE Combining chemistry, automation, sensors & data analytics

Water Experts

Data Scientists

3D TRASARTM

Technology

Weather Data

Predict performance of critical assets

Prevent unscheduled downtime & lost production

Prolong asset life & production runtime

Page 20: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

20

End to End Architecture

Page 21: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

21

B2B Data Connections – Why PI Cloud Connect?

• ENABLES real-time data sharing for analytic models to be actionable

• ACCELERATES deployment delivering value to the customer

• SECURED data sharing without Virtual Private Networks (VPNs)

• PREFERRED method for customers with OSIsoft PI

• EASY to Install, Connect, Configure.

• MANAGED by OSIsoft with minimal On-premises footprint

• SCALABLE and reliable solution based on Microsoft Azure

• WEB-BASED portal for configuration and monitoring

Page 22: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

PI System

Company A

Domain Ecolab PI Infrastructure

PI Connect

Node

PI Connect

Node

PI Cloud Connect enables

Publish/Subscribe integration from

Customer to System Assurance Center

PI Cloud

Connect

PI System

PI System PI System

PI Cloud Connect

Page 23: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

23

Examples of Customer AF setup

Page 24: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

24

Sample of PI Cloud Connect Setup

• Publish and Subscribe

• Wizard-based configuration

Page 25: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

Secure

Networks

Built through a partnership

to deliver secure, intelligent and scalable

solutions to minimize water, maximize results and optimize total cost of operations

Working together

of global leaders

Innovative

Chemistry /

Equipment

Actionable

Insights

World Class

Service

Azure &

PowerBI Field

Service

O365 &

Software Security

G360

Sales &

Service

OIP /

Cumulus

Analytics

/ Insights

Asset

Mgmt

Trends &

Strategy

IoT +

Analytics

Portal /

Setup Integration CRM

Clean Water Safe Food Abundant

Energy

Healthy

Environments

Azure

Friendly Security

+ +

Page 26: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

THE BENEFITS

26

Page 27: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

Once through circ water

system

Elevated DO and cation

conductivity in the

condensate

OMNI indicated air in-

leakage correlated to

“bravo” CD pump

OUTCOMES

1% Heat rate

penalty by

$100,000/month

Reduced pump

maintenance

cost

Four 2x1 Combined Cycle Power Block

Page 28: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

• With titanium condenser

• Well water makeup

• Aluminum fouling observed in test rack

• OMNI confirmed condenser degradation

OUTCOMES Single Unit Coal-Fired Power Plant

Improved asset

reliability

> $500,000

fuel savings

Page 29: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

• Uses brackish water for once through condenser cooling

• OMNI identified inlet tube sheet fouling leading to higher temperature rise and backpressure on the condenser

OUTCOMES 2 Unit Nuclear Power Plant

Reduced costs

to mitigate

reactivity control

risks

Reduced labor

costs for cleaning

$100,000

Generating

revenue

restored $3M

Page 30: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

30

Page 31: Predictive Analytics for Reliable High Power Performance · High Performance Pre-Treatment Cooling Tower Post-Treatment Boiler Water In Wastewater Out Condenser . #PIWorld ©2019

#PIWorld ©2019 OSIsoft, LLC

31

Questions?

Please wait for

the microphone

State your

name & company

Please remember

DOWNLOAD THE MOBILE APP


Recommended