www.bloomeng.com
Prepackaged & portable Combustion & Controls System with adjustable firing arm for preheating multiple small units
Preheater Cart & Torch
Features
Multi-direction adjustable firing arm
Pivoting head can serve multiple units
Adjustable height
Preheat small units such as crucibles, ladles, pump wells, troughs, or refractory lining in pipes
Combustion & high/low control system designed per NFPA 86
UV detection
Direct spark ignition
Combustion air supplied by inspirator and compressed air (no blower)
NOx < 35 ppm [@ 3% O2, 1000 °C (1832 °F), & high fire]
Quick disconnect air & gas hoses
Utilizes the Bloom Hotwork Minijet 4 (MJ04) Burner
U.S.A.
Bloom Engineering Company, Inc.
Corporate Headquarters
5460 Horning Road
Pittsburgh, PA 15236-2822
Main: 412-653-3500
www.bloomeng.com
Our Mission:
To enable our customers’ long term success by providing combustion
products, systems, and services that achieve optimal productivity,
efficiency, and environmental performance. Our global team delivers
this with industry-leading expertise and innovative solutions.
Copyright © 2018 Bloom Engineering. All rights reserved.
The Cart & Torch assembly provides safe and portable combustion that can preheat multiple units
Compressed Air Supply
Burner
Combustion Air
Natural Gas
1 System inlet requires natural gas at 10-40 psig (70-275 kPa), compressed air at 60—100 psig (400-700 kPa), and 120V power 2 Maximum burner capacity can be pushed to 400,000 Btu/hr (117 kW) 3 Combustion Air supplied by an inspirator with compressed air; Air flow is constant for high and low fire
UV Detector
Direct Spark
Ignitor
Adjustable Arm
Table 1: Performance1
Nominal Operating Capacity2 300,000 Btu/hr 87.9 kW
Minimum Operating Capacity 50,000 Btu/hr 14.7 kW
Air Flow (Nominal)3 3,300 scfh 88.4 Nm3/hr
Air Pressure (Nominal) 5.00 "w.c. 12.4 mbar
Natural Gas Flow (Nominal) 300 scfh 8.0 Nm3/hr
Natural Gas Flow (Low Fire) 50 scfh 1.3 Nm3/hr
Natural Gas Pressure (Nominal) 0.6 "w.c. 1.5 mbar
Natural Gas Pressure (Low Fire) 0.02 "w.c. 0.05 mbar