OXICOM LITIC
INDUSTRIAL ı COMPACTO ı PREMONTADO
Electrolytic ozone generator for
pure and demineralized water,
for continuous disinfection of
water storage and distribution
systems (systemic protection).
Suitable for purified water or
comparable specifications for
Aqua Purificata, WFI (Water for
Injection/Aqua ad Injectabilia) or
comparable specifications in the
pharmaceuticals-, cosmetics-
and semi-conductor industry,
hemodialysis, biotechnology as
well as in medical systems.
• Short-circuit-proof power supply
• Stainless steel housing
• Redundant operation (off ELAP
2800)
• Easy change of components
• Downward compatible to all ELAP
ozone cells (up to 4,0 g O3/h)
• Configurable alarm outputs
• Automatic logging of operating states
and alarms
OXICOM
LITIC
INDUSTRIAL ı COMPACTO ı PREMONTADO
ELECTROLYTIC OZONE
GENERATOR
• Purest ozone (no added substances) Low energy- and operating costs • High safety (work and microbiological protection) Fine and more accurate ozone
dosage
• High ozone concentration in the water
• Approvals: (USP, Ph. Eur., JP, ANSI/AMMI, GMP, ISPE, FDA, NEMA, UL)
OXICOM LITIC ELECTROLYTIC OZONE GENERATOR
Modelo
Ozone
Production
g/h
Power
Supply
LITIC – 1,5 1,5 240V-50 Hz
LITIC – 3 3,0 240V-50 Hz
LITIC – 4 4,0 240V-50 Hz
LITIC – 5 5,0 240V-50 Hz
Features of the control unit (execution: Master-SV-S)
Output power: Current controlled 0…6 VDC 0...45 A max. 250 W (at ELAP
5.0)
Display and Control: 10 inch touch display (switchable language)
Emergency control by magnet switch and 7 segment display
Input for REMOTE ON/OFF: (1x per ozone cell) By means of closing contact
Input 4...20 mA for: (1x per ozone cell) Control ozone capacity
Potential free contacts for: (48 VDC / 1A)
(1x per ozone cell)
Common alarm 1
Common alarm 2 Ozone production
Outputs 4...20 mA for:
(1x per ozone cell)
Operating voltage of cell
Operating current of cell
Operating temperature: 0…40°C
Protection class of power supply: IP 65 (DIN 40 050 IEC 529, EN 60 529 / 10.91)
Protection class: Class I, protection grounding (acc. to DIN 57 100 resp. VDE
0100 and 0106 T1)
Emergency supply at mains shut down: (1x per
ozone cell) By means of accumulator 48 h for at least
Mains connections: 110…230 V AC, 50/60 Hz, 400 VA
Power factor: > 0,95
Weight: approx. 25 kg
OXICOM LITIC ELECTROLYTIC OZONE GENERATOR
Features of the ozone cell
Material Stainless steel DIN EN 10 027 mat. 1.4571 (AISI 316Ti) PTFE
No. of cells per apparatus: 1
Ozone concentration: (in the water phase) Depends on the actual water flow
Flow during standby:
Periodically a small flow to fill up the ozone cell
continuously a very small flow (the ozone cell must always
be filled with water!)
Flow during production: approx. 100...250 ℓ/h (150 ℓ/h nominal)
Water quality: Demineralized water, conductivity < 10 µS/cm (purified
water or comparable specification)
Water temperature: approx. 15...25 °C
Operating temperature of the cell: < 50 °C, nominal 30...40 °C
Temperature measurement: Sensor integrated
Flow measurement Sensor for short water integrated
Pressure measurement Sensor integrated
Display of parameter Display
Parameter transfer to control unit Data bus
Pressure resistance of the cell: + 16 bar
Operating pressure of the cell: + 0...10 bar
Dimensions of the cell: approx. 305 x 125 mm (without Clamp connector);
installation depth min. 135 mm
Hydraulic connections: R/G 3/8“ or Clamp connector
Connection for hydrogen disposal: R/G 1/8“
Hydrogen gas quantities: approx. 27 Nℓ/h
Seals and el. insulation material: (in contact with
the agents)
PTFE, FEP
(according to FDA)
Protection class of the cell: IP 26 (DIN 40 050 IEC 529, EN 60 529/10.91)
Standard cable length: 5 m
Weight: Approx. 4 kg (at ELAP 5.0)
OXICOM LITIC ELECTROLYTIC OZONE GENERATOR
Electrolytic Cell Slave Master