Popular Tags:
18
New STANDESSE Comfort ...BRAND NEW STAR IN AIR CURTAINS! © 2VV spol. s r.o. – 18.7.2011
Transcript
Page 1: Presentation Standesse New v.18.7.11 En

New STANDESSE Comfort

...BRAND NEW STAR IN AIR CURTAINS!

© 2VV spol. s r.o. – 18.7.2011

Page 2: Presentation Standesse New v.18.7.11 En

New STANDESSE

… BRAND NEW STAR IN AIR CURTAINS

Page 3: Presentation Standesse New v.18.7.11 En

Length up to 2.5 m

Modular control system

Simple maintenance and repair

Low noise level

New STANDESSE

New features

Page 4: Presentation Standesse New v.18.7.11 En

3 capacity lines

A – up to 4500 m3/h

B – up to 5500 m3/h

C – up to 6300 m3/h

Configuration

Water

Electric

Cold (B,C)

Technical Parameters

24.5

kW

72.12

kW

Ran

ge u

p to

8.0

m

Ra

ng

e u

p to

6.5

m

Ra

ng

e u

p to

5.0

m

Page 5: Presentation Standesse New v.18.7.11 En

4 lengths

• Standard - stainless steel strip on the suction cover

- curtain colour RAL 9010

length 1.0m

length 1.5m

length 2.0m

Technical Parameters

length 2.5m

Page 6: Presentation Standesse New v.18.7.11 En

Module control system

Control module – same for all control systems SM, DM and DA.

Control module - installed using connectors.

Page 7: Presentation Standesse New v.18.7.11 En

Module control system

Universal solution – every curtain is multipurpose

• Far fewer models to hold in stock

Easy to switch control system on an already-installed curtain

• Easy upgrade of a curtain from the basic SM to the comfortable DM configuration.

Plug & Play configuration

• Easy access and installation of modules

Page 8: Presentation Standesse New v.18.7.11 En

Functionality:

Manual control system (230V)

3 fan speeds

2 electric heating levels

Water control using a thermostatic valve

External switches: door contact

SM control module

Without heating

Water version

Electric version

Content of the control module:

Module

SM panel

Operating instructions

Page 9: Presentation Standesse New v.18.7.11 En

Functionality:

Manual control system

Radio frequency wireless control

2 electric heating levels

ON-OFF water heating control

(ZV-3)

3 fan speeds

LED operating light on the body of the

curtain

Door contact (and TER-P for the water

version)

Unlimited chaining in the radio signal

range (about 100m)

DM control module

Without heating

Water version

Electric version

Content of the control module:

Module

DM panel

Operating instructions

NEW

NEW

NEW

NEW

Page 10: Presentation Standesse New v.18.7.11 En

Functionality:

Manual or automatic control system

Radio frequency wireless control

3 fan speeds

Continuous heating control – electric and water!

2 integrated temperature sensors + 1 external temperature

sensor

Room temperature – sensor on the suction of the curtain

Temperature at exhaust – on the control system housing

Outdoor temperature sensor – located outside

Integrated timer

BMS connection - ModBUS RTU

Unlimited chaining – in radio signal range (approx

100m) + cable chaining max. 6 units

Content of the control module:

Module

DA panel

Operating instructions

Outdoor sensor

DA control module

Water version Electric version

NEW

NEW

NEW

NEW

NEW

Page 11: Presentation Standesse New v.18.7.11 En

Heater replacement

Heaters are integrated in the structural frame

• Electric and water

Easy to exchange

• 4 screws on each side

Electric heater without cables

• Only 1 connector

Simple maintenance and repair

Page 12: Presentation Standesse New v.18.7.11 En

Replacement of fans

• Fans are grouped on

independent rails

The suction cover serves also as a filter

• Cleaning with a vacuum cleaner.

Simple maintenance and repair

Page 13: Presentation Standesse New v.18.7.11 En

56,6 dB(A)* at an output of 6 300 m3/h

• Value at maximum fan power, length of curtain 2.5 m

• Noise insulation of the housing

• Specially designed shape of the exhaust

*acoustic pressure value at a distance of 3m

Low noise level

Page 14: Presentation Standesse New v.18.7.11 En

Accessories

Air curtains

execution Air only With electric heater With water coil

(VCS4x-xxS...) (VCS4x-xxE...) (VCS4x-xxV...)

Re

qu

ire

d a

cc

es

so

rie

s

Control module

SM DM SM DM DA SM DM DA

(VCS-R-SM-S) (VCS-R-DM-S) (VCS-R-SM-E) (VCS-R-DM-E) (VCS-R-DA-E) (VCS-R-SM-V) (VCS-R-DM-V) (VCS-R-DA-V)

External temperature

sensor X X X X

Included with

control module X X

Included with

control module

Water coil regulator

X X X X X

TV1/1

(Thermostatic

valve)

ZV-3

(Zone valve)

MV-3

(Mixing valve)

Op

tio

na

l a

cc

es

so

rie

s

Door switch

DS X DS X X DS X X

Door contact

X DK-1 X DK-1 DK-1 X DK-1 DK-1

Room thermostat

X X X X X X TER-P X

Ceiling mounted

brackets VCS4-KONZ-STR VCS4-KONZ-STR VCS4-KONZ-STR

Wall mounted

brackets VCS4-KONZ-STE VCS4-KONZ-STE VCS4-KONZ-STE

Exit sign for marking

of emergency exits VCS4-EXIT VCS4-EXIT VCS4-EXIT

Page 15: Presentation Standesse New v.18.7.11 En

Applications

Administrative centres

Shopping centres

Hypermarkets

Banks

Hotels

Cafés

Hospitals

Page 16: Presentation Standesse New v.18.7.11 En

Product support

Design program

3-year warranty

Technical support

Page 17: Presentation Standesse New v.18.7.11 En

Summary of advantages

Length up to 2.5 m

Modular control system

Simple maintenance and repair

Low noise level

Radio frequency wireless control

Modern and attractive design

Page 18: Presentation Standesse New v.18.7.11 En

Thank you for your attention


Recommended