...closer to the patient
Pressure Area CareProduct Range Features
and Technical Data...we help reduce avoidable harms
Air Mattresses AirOverlays
Hybrid Mattresses
(Foam + Air)
Foam Mattresses Cushions
ProductFeature
QU
ATTR
O® A
cute
QU
ATTR
O®
Paed
iatri
c
QU
ATTR
O® P
lus
PULS
AIR
™ C
hoic
e M
attre
ss
QU
ATTR
O®
Sent
inel
QU
ATTR
O®
Ove
rlay
PULS
AIR
™ C
hoic
e O
verla
y
FUSI
ON
™ H
ybrid
FUSI
ON
™
Res
pons
e
POLY
FLO
AT™
Su
prem
a
POLY
FLO
AT™
D
orm
ira
ATTI
VO™
+
B.A.
S.E.
™ S
eque
ntia
l C
ushi
on /
Rec
liner
Mat
FUSI
ON
™ H
ybrid
PULS
AIR
™ C
hoic
e
POLY
FLO
AT™
C
ushi
on
Ther
apy
Mod
e Active Therapy
1-in-4 cell type l l l l l l l
1-in-2 cell type l l l l
Reactive Therapy l l l l l l l l l l l
Cycle Duration (Minutes)
Variable (10-30)
Variable (10-30) 16 16 16 16 8 8 16 8 8
Air C
ell
Feat
ures
DEEP CELL THERAPY l l
TISSUEgard l l l l
Ortho-differential Support (ODS) l l l l l l l
Pow
er U
nit F
eatu
res
/Fu
nctio
ns
AUTOsupport l l l l l l l l l l l
Continuous Low Pressure l l l l l
Maximum Inflation l l l l l
Comfort Control l l l l l l l l l l l
PHASE FLOW l l l l l l l l l l l
Cov
er F
eatu
res
/Fu
nctio
ns
Multi-stretch l l l l l l l l l l l l l l l
Moisture Vapour Permeable l l l l l l l l l l l l l l l
Welded Cover Seams l l l l l l l l l l l l l l l
Machine Washable Cover l l l l l l l l l l l l l l l
Mat
tress
Fea
ture
sLow Air Loss l l l l l l l
Machine Washable Mattress l l l l
CPR l l l l l l l l
Transport Facility l l l l l l l
Cable Management l l l l l
Mis
c.
Active Seat Cushion Available l l l l l
Modular Construction l l l l l l l l l l l
Pressure Area Careproduct range features
Pressure Area Careproduct range features
ACTIVE THERAPY
Active support surfaces periodically redistribute the pressure beneath the body and are recommended by the EPUAP / NPUAP for a wide range of patients who cannot be regularly repositioned.
REACTIVE THERAPY
Reactive therapy enhances patient immersion and envelopment into the mattress and applies a constant low pressure to the skin and subcutaneous tissue.
The
rap
y M
od
e
The
rap
y M
od
e
ACTIVE 1-IN-4 CELL CYCLE
An active 1-in-4 cell cycle supports 75% of the patient’s body at all times, on groups of three inflated cells, whilst the fourth cell deflates sufficiently to
redistribute the pressure and encourage tissue reperfusion. Additional benefits include enhanced patient comfort, less awareness of support surface movement and a reduction of stimulus-related complications such as muscle spasm.
The
rap
y M
od
e
DEEP CELL THERAPYTM
DEEP CELL THERAPY allows the cells of the QUATTRO Acute to run at
lower internal pressures. This minimises the pressure applied to the patient’s skin and subcutaneous tissues during the cycle.
TISSUEGARDTM
TISSUEgard enables the partial immersion and envelopment of the patient into the support surface, reducing the
pressure on the patient’s skin and decreasing the pressure differential between inflated and deflated cells, which helps reduce tissue strain and associated shearing forces.
Air
Cel
l Fea
ture
s
Air
Cel
l Fea
ture
s
ORTHO-DIFFERENTIAL SUPPORTTM
ODS results in firmer outer edges of the mattress which facilitate patient
transfers and provide extra support, safety and comfort for larger or heavier patients. It also creates a softer central area of the mattress, ideal for smaller, lighter patients.
Air
Cel
l Fea
ture
s
AUTOSUPPORTTM
AUTOsupport automatically adjusts pressure within each of the cells throughout the cycle so that support,
posture and therapy are constantly maintained at optimum levels, in response to patient weight, movement and position. Equalisation of cell pressure automatically takes place at each stage of the cycle, again to ensure precise pressure and therapy is applied.
CONTINUOUS LOW PRESSURE
When in Continuous Low Pressure mode pressure is equalised within the cells to create a reactive therapy surface,
allowing greater immersion and envelopment into the mattress and optimum pressure distribution.
Po
wer
Uni
t F
eatu
res
Po
wer
Uni
t F
eatu
res
MAXIMUM INFLATION
Inflates the mattress to maximum static pressure for 15 minutes before returning to previous therapy mode, necessary for some nursing procedures when an active support surface is unsuitable.
Po
wer
Uni
t F
eatu
res
COMFORT CONTROL
Allows the carer to adjust the comfort setting in either therapy mode to help patient compliance.
PHASE FLOWTM
PHASE FLOW pressure control pump operates on demand only,
reducing power consumption, noise and extending service life.
Po
wer
Uni
t F
eatu
res
Po
wer
Uni
t F
eatu
res
MULTI-STRETCH
The multi-stretch cover promotes tissue offloading during cell deflation and reduces shear and friction during patient movement or manual repositioning. The material is waterproof, moisture-vapour permaeable and all seams are welded to protect the inside of the mattress from fluid ingress.
Co
ver
Fea
ture
s
Energy-efficient
MODULAR CONSTRUCTION
Simple to repair/service on site for minimum downtime.
Mis
c.
REACTIVE THERAPY(pressure reducing)
ACTIVE THERAPY(pressure relieving)
1-IN-4
REACTIVE THERAPY(pressure reducing)
ACTIVE THERAPY(pressure relieving)
LOW AIR-LOSS
Air is released and circulated beneath the mattress
cover to reduce humidity and help manage the skin 'microclimate' between the patient and the support surface.
Mat
tres
s F
eatu
res
Dimensions / Materials
Air Mattresses Air Overlays
Hybrid Mattresses
(Foam + Air)
Foam Mattresses Cushions
QU
ATTR
O® A
cute
QU
ATTR
O®
Paed
iatri
c
QU
ATTR
O® P
lus
PULS
AIR
™ C
hoic
e M
attre
ss
QU
ATTR
O®
Sent
inel
QU
ATTR
O®
Ove
rlay
PULS
AIR
™ C
hoic
e O
verla
y
FUSI
ON
™ H
ybrid
FUSI
ON
™
Res
pons
e
POLY
FLO
AT™
Su
prem
a
POLY
FLO
AT™
D
orm
ira
ATTI
VO™
+
B.A.
S.E.
™ S
eque
ntia
l C
ushi
on /
Rec
liner
Mat
FUSI
ON
™ H
ybrid
PULS
AIR
™ C
hoic
e
POLY
FLO
AT™
C
ushi
on
Pow
er U
nit D
imen
sion
s Length (mm) 355 355 355 355 355 355 355 355 210 355 355
Height (mm) 233 233 233 233 233 233 233 233 105 233 233
Depth (mm) 165 165 165 165 165 165 165 165 205 165 165
Weight (kg) 3.4 3.4 3.4 3.4 3.4 3.4 3.4 3.4 2.2 3.4 3.4
Mat
tress
/ C
ushi
on
Dim
ensi
ons
Length (mm) 1980 1300 1950 1950 2000 1930 1930 1970 1970 1980 1980 430 / 1080 430 430 430
Width (mm) 900 650 880 880 1200 850 850 880 880 880 880 430 430 430 430
Depth (mm) 240 180 180 180 180 130 130 170 170 150 150 70 65 40 76
Weight (kg) 12.5 6.6 10.5 8.6 23.4 6.8 5.5 11.9 11.9 14.0 11.0 1.9 / 3.9 1.1 1.3 1.0
Mat
tress
/ C
ushi
on
Mat
eria
ls
PU Air Cells l l l l l l l l l l l l
Foam l l l l l l l l
PU Coated Stretch Nylon
Coverl l l l l l l l l l l l l l l
Mis
c.
Number of Air Cells 27 20 30 30 17 17 17 18 18 48 /
120 7 8
Maximum user weight (kg) 250 95 200 200 370 160 127 250 250 250 250 127 150 102 160
Minimum User Weight None None None None None None None None None None None None None None None
Talley manufacture products to comply with National and International safety standards and are certified to ISO9001, ISO13485 and Directive 93/42/EEC. Every care has been taken to ensure that the information contained in this brochure was correct at the time of going to press. However, Talley reserve the right to modify the specification of any product without prior notice in line with a policy of continual product development. Our standard terms and conditions apply. © Talley Group Limited 2016. All rights reserved.
02/2
017
SIN C E 1953
GRE
AT
BRITI
SH D
ESIGN AND MANUFAC
TURIN
G
Talley Group LimitedPremier Way, Abbey Park Industrial EstateRomsey, Hampshire, SO51 9DQ England
TEL: +44(0)1794 503500FAX: +44(0)1794 503555
EMAIL: [email protected]
QUATTRO Acute, QUATTRO Plus, QUATTRO Sentinel, QUATTRO Overlay, PULSAIR Choice, FUSION Hybrid, FUSION Response, POLYFLOAT Suprema, POLYFLOAT Dormira, ATTIVO, B.A.S.E. Sequential and B.A.S.E. Recliner Mat are Registered Trade Marks of Talley Group Limited
Visco-elastic
Pressure Area Careproduct range technical data
Visco-elastic
860mm with-out bolsters
Bolsters and base