Page 1: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

www.osram.com/prevaled

Light is OSRAM

03/2016

Technical application guide PrevaLED® Cube G3 LED modules

Page 2: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Contents

2

Please note:All information in this guide has been prepared with great care. OSRAM, however, does not accept liability for possi-ble errors, changes and/or omissions. Please check www.osram.com or contact your sales partner for an updated copy of this guide. This technical application guide is for information purposes only and aims to support you in tack-ling the challenges and taking full advantage of all opportu-nities the technology has to offer. Please note that this guide is based on own measurements, tests, specific parameters and assumptions. Individual applications may not be covered and need different handling. Responsibility and testing obligations remain with the luminaire manufacturer/OEM/ application planner.

Contents

1 Introduction 03

1.1 System overview 03

1.2 Nomenclature 03

2 Optical considerations 04

2.1 Light distribution 04

2.2 Reflector design 04

2.3 Color temperature 05

2.4 Color rendering 05

2.5 Spectral distribution 06

2.6 Luminous flux behavior 06

3 Electrical considerations 07

3.1 Forward voltage as a function of temperature 07

3.2 Driver compatibility 07

3.3 Wiring 08

3.4 OTi DALI LED drivers 09

3.5 OT FIT LED drivers 09

3.6 OTe LED drivers 09

3.7 LEDset2 (LT2) 10

3.8 ESD 10

4 Thermal considerations 11

4.1 Thermal power values 11

4.2 Operating current as a function of temperature 11

4.3 Thermal protection features 12

4.4 TIM and other accessories 12

4.5 Cooling system and heat sink 13

4.6 tc point location and temperature measurement 13

4.7 Thermocouple 14

5 Lifetime and thermal behavior 15

5.1 Luminous flux as a function of temperature 15

5.2 Lifetime 16

6 Mechanical considerations 17

6.1 Outline drawing 17

6.2 3D drawing 17

6.3 Mechanical protection of the light engine 17

6.4 Mounting 17

7 Norms and standards 18

Page 3: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Introduction

3

1.1 System overviewBuilding an LED-based luminaire poses a set of technical challenges, among them optical requirements, providing adequate thermal management for stable operation and dealing with the improving performance of LEDs. Never- theless, LED technology also provides an unknown number of possibilities, opening up unprecedented levels of perfor-mance.

OSRAM’s PrevaLED® family of LED light engines addresses the challenges of LED-based lighting while providing users with great performance and flexibility at the same time. En-abled by the application of LED technology, PrevaLED® is aiming to push the envelope of what is possible in terms of performance and simplicity.

PrevaLED® Cube G3 LED light engines offer one of the best and easiest ways to outfit luminaires with LED technology. They are ideally suited for use in highly diffuse wall-mounted and ceiling-mounted luminaires in decorative, hospitality or domestic application as well as a broad range of wide- reflector-based luminaires such as downlights.

Future-proof conceptTo allow for a smooth transition to this new generation of the PrevaLED® Cube series, crucial features have remained the same:

— Complete portfolio in terms of luminous flux, color temperature and color rendering

— Same form factor and mechanical/optical interfaces as previous generation

— High driver flexibility allows cost-effective and intelligent systems

— 5-year guarantee (for current terms and conditions of the guarantee, please visit www.osram.com/system-guarantee)

— Selection of dimmable and non-dimmable LED drivers

1 IntroductionOf course, important improvements have been realized as well:

— High flexibility through four lumen packages and four color temperatures: The PrevaLED® Cube G3 series is available as a 1 100 lm, 2 000 lm, 3 000 lm and soon 5 000 lm package in two light colors (3 000 K and 4 000 K); further light colors (2 700 K and 3 500 K) and the PrevaLED® Cube G3 board version are available upon request through your sales partner

— Low height of optical contact area (OCA) of 18.6 mm for compact luminaire design

— Near Lambertian light distribution for best quality of light in diffuser as well as reflector-based applications

— Industry-standard mounting holes and light-emitting surface (LES) for use with standard heat sink and reflector accessories

— Lifetime (L70B50) at tc = 80 °C: 50 000 hours — Improved poke-in connector for stranded and solid wires

— Very good light quality — Very high efficiencies for smaller heat sinks and easier thermal management

— Typical module efficacy: up to 135 lm/W — tc max: 90 °C — Thermal protection

— Thermal derating with LEDset2 — Thermal shutdown

1.2 Nomenclature

PL-CUBE-1100-827-G3

PL-CUBE: PrevaLED® Cube family1100: 1100 lm

G3: Generation 3

8: CRI > 80

27: Color temperature, 2700 K

Page 4: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Optical considerations

4

2 Optical considerations2.1 Light distributionThe light distribution of PrevaLED® Cube G3 light engines is shown below. They create a beam angle of 110° FWHM.

The PrevaLED® Cube G3 board version has an even wider beam angle of 120° FWHM.

Light distribution curve

2.2 Reflector design The light-emitting surface of the light engines is covered by a diffuser to ensure a homogenous, smooth light distribu-tion. Please ensure that the temperature of the diffuser does not exceed 120 °C.

PrevaLED® Cube G3 light engines can also be used with secondary optics. As their optical interface has the same dimensions as common downlight modules in the market, they can be combined with available off-the shelf second-ary optics.

OSRAM provides mechanical (3D files) and optical simula-tion data (ray files) to support customized reflector design. Ray file data are available upon request through your sales partner.

For optics support, you can find our partners via OSRAM’s LED Light for You network: www.ledlightforyou.com. Moreover, standard components and support for reflector design are available e.g. through the following suppliers:

Jordan Reflektoren GmbH & Co. KGSchwelmer Strasse 161, 42389 Wuppertal, Germany +49 202 60720 [email protected] www.jordan-reflektoren.de

ACL-Lichttechnik GmbHHans-Boeckler-Strasse 38 A, 40764 Langenfeld, Germany+49 2173 9753 [email protected]

Jordan Luxar GmbH & Co. KGSchneiderstrasse 76 d, 40764 Langenfeld, Germany Phone: +49 (0)2173 279-0, Fax: +49 (0)2173 [email protected]

Almeco S.p.A.Via della Liberazione, 15, 20098 San Giuliano Milanese (Mi), Italy+39 02 988963 [email protected]

Nata Lighting Co., Ltd.380 Jinou Road, Gaoxin Zone, Jiangmen City, Guangdong, China +86 750 377 [email protected] www.nata.cn

Widegerm Lighting Ltd.Flat A, 3/F., Tak Wing Ind. Building 3 Tsun Wen Rd. Tuen Mun, N.T., Hong Kong+85 224 655 [email protected] www.widegerm.com.hk

Page 5: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Optical considerations

5

2.3 Color temperature The PrevaLED® Cube G3 series is currently available in2 700 K, 3 000 K, 3 500 K and 4 000 K. The color coordi-nates within the CIE 1931 color space are given below.

2.4 Color rendering PrevaLED® Cube G3 LED modules provide a color render-ing index (CRI) of > 80. The table below shows the indivi-dual Ra values from R1 to R14 for the available color temperatures.

Within each available color temperature, the PrevaLED® Cube G3 series provides a maximum color variation of three threshold value units (MacAdam steps). The diagram on the right shows these threshold values within the CIE 1931 color space.

Initial color vales of the CCT

2700 K 3000 K 3500 K 4000 K

Cx 0.464 0.439 0.412 0.387

Cy 0.412 0.405 0.394 0.384

Color coordinates

Ra values

Du

sky

pin

k

Mu

sta

rd y

ello

w

Ye

llow

ish

gre

en

Lig

ht

gre

en

Turq

uo

is

Azu

re

Ast

er

vio

let

Lila

c vi

ole

t

Re

d, s

atu

rate

d

Ye

llow

, sa

tura

ted

Gre

en

, sa

tura

ted

Blu

e, s

atu

rate

d

Pin

k, s

kin

co

lor

Le

af

gre

en

Ge

ne

ral C

RI

R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R14 Ra

CCT = 2700 K 79 91 95 78 79 90 81 55 5 80 76 74 82 98 81

CCT = 3000 K 80 90 97 79 80 87 83 59 7 77 78 69 82 99 82

CCT = 3500 K 81 90 97 80 81 87 85 62 9 77 78 66 83 99 83

CCT = 4000 K 81 90 96 81 81 85 87 65 12 75 80 63 83 98 83

These color coordinates apply to PrevaLED® Cube G3 incl. housing

Typical values of PrevaLED® Cube G3 with 2000 lm

Three-step MacAdam ellipsesy

0.39 0.41 0.43 0.47

4000 K

3500 K

3000 K

2700 K0.42

0.40

0.38

0.37

x

0.450.37

0.39

0.41

Page 6: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Optical considerations

6

2.5 Spectral distributionThe typical spectral distribution of the PrevaLED® Cube G3 LED modules is shown in the following diagram.

2.6 Luminous flux behaviorThe following diagrams show the luminous flux as a func-tion of the operating current for PrevaLED® Cube G3 LED modules with 1 100 lm, 2 000 lm and 3 000 lm. The data re-lated to the operating current is derived from a tp tempera-ture of 75 °C.

Wavelength spectrum

Flux normalized at rated current [%] Flux normalized at rated current [%]

Flux normalized at rated current [%]

PL-CUBE-1100-G3 PL-CUBE-2000-G3

PL-CUBE-3000-G3

0

0

0

0

0

20

40

60

80

100

120

140

160

0

50 50

100100

150150

100

200

100200

400

200400

600

400500

800

500300 300600

1000

600700

If [mA]

If [mA]

If [mA]

0.00

0.20

0.40

0.60

0.80

1.00

400 450 500 550 600 650 700 750 800 850

Realtive spectral emission [% · 100]

827 830 835 840

Wavelength [nm]

700 800

Page 7: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Electrical considerations

7

3 Electrical considerations3.1 Forward voltage as a function of temperature

3.2 Driver compatibility

PL-CUBE-3000-G3

PL-CUBE-2000-G3

Uf typ [V] Uf typ [V]

Uf typ [V]

PL-CUBE-1100-G3

-20 -20

-20

21.5 30.5

30.5

22.0 31.0

31.0

22.5 31.5

31.5

23.032.0

32.0

23.532.5

32.5

33.0

33.0

0 0

0

20 20

20

60 60

60

80 80

80

100 100

100

40 40

40

tc [°C] tc [°C]

tc [°C]

Drivers Modules

PL-C

UBE-

1100

-830

PL-C

UBE-

1100

-840

PL-C

UBE-

2000

-830

PL-C

UBE-

2000

-840

PL-C

UBE-

3000

-830

PL-C

UBE-

3000

-840

OTe 13/220-240/350 PCOTe 25/420 CSOTe 35/700 CSOT FIT 25/500 CSOT FIT 35/700 CSOTi DALI 15 LT2OTi DALI 25/700 LT2OTi DALI 35/1A0 LT2OT FIT 15/500 LT2OT FIT 25/700 LT2OT FIT 40/1A0 LT2

tested compatibility preliminary compatibility

Compatibility of PrevaLED® Cube with OPTOTRONIC®

Note: For the maximum allowed number of LED drivers per circuit breaker, please see the datasheet of the driver at www.osram.com/ot.

Page 8: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Electrical considerations

8

Solid wirePlug directly.

Flexible wire1. Lightly press the push

button of the connection clamp.

2. Insert the flexible wire.

To press/release the clamps, please use an operating tool (Wago type: 206-860) or a small screw-driver.Notes:

— The connector is designed for three “poke-in” and release cycles.

— The installation of LED modules has to be carried out in compliance with all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations.

3.3 WiringThe used input clamps can handle solid or flexible wire with a cross-section of 0.2 to 0.75 mm2 (AWG 24–18). The use of solid wire is recommended.

Example: H05V-U 1x 0.5 mm2

6–7 mm(0.24–0.28 inches)

Wire preparation

Page 9: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Electrical considerations

9

3.6 OTe LED driversIf you want to use the OSRAM OTe series, please connect the terminal LED+ to the LED module and select the desired current by connecting it to only one of the output terminals 21, 22 or 23.

3.5 OT FIT LED driversIt is also possible to use the PrevaLED® Cube G3 series with a constant-current LED driver. The OT FIT series offers different available currents. To wire the LED module to the LED driver, please connect the terminals LED+ and LED- to the LED module as shown in the image below. The current is selected by a bridge between ports 3, 4 and 5. The new OT FIT LT2 drivers will also support the LEDset2 functional-ity as explained above in chapter 3.4.

3.4 OTi DALI LED driversIf you use the PrevaLED® Cube G3 series in combination with the OSRAM OTi DALI LED driver series, you will getthe best results and the full functionality of the LED module.

The system includes a one-wire communication interface, using the LEDset2 communication standard between the LED driver and the LED module. A thermal derating anda luminous flux calibration are included. Therefore, please connect all three terminals of the module to the LED driver.

OTi DALI 50/220-240/1A4 LT2 FAN

OTe 35/220-240/700 CS

OT FIT 25/220-240/500 CS

Page 10: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Electrical considerations

10

3.7 LEDset2 (LT2) LEDset helps you to meet important market requirements:

— Future-proof solutions in terms of luminous flux — Long-life operation — Luminaire customization — Energy and cost savings

LEDset2 (LEDset generation 2) is the enhanced interface between OPTOTRONIC® LED drivers and LED modules (such as OSRAM PrevaLED®). It can be identified by the product name of the LED driver, including the letters “LT2” at its end.

LEDset2 is based on a three-wire connection between the LED driver and the LED module. This interface is designed to allow communication between the LED module and the LED driver, performing LED current setting and thermal protection functionality.

Combined with PrevaLED® Cube G3 LED modules, the interface supports the following functionalities:

— Absolute output current setting of the constant-current LED driver (LED module self-recognition)

— Thermal protection of the LED module

LEDset2 allows a selection of the output current through the simple selection of the proper Rset resistor value and the connection of a potentiometer or a fixed standard resistor to the LEDset line. The relationship Iout vs. Rset is defined by the following formula:

Iout [A] = Rset [Ω]

5 V x 1000

Note: More detailed information about the possibilities of LEDset2 interfaces can be found in the corresponding driver appli-cation guidelines and at www.osram.com/ledset.

3.8 ESDIt is not necessary to handle PrevaLED® Cube G3 LED modules with housing in electrostatic protected areas (EPAs). To protect a PrevaLED® Cube G3 LED module from electrostatic damage, do not open it. The PrevaLED® Cube G3 board version without housing must be handled in elec-trostatic protected areas.

Page 11: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Thermal considerations

11

4 Thermal considerationsThe proper thermal design of an LED luminaire is critical for achieving the best performance and ensuring the lon-gest lifetime of all components. Due to the high efficacy of PrevaLED® Cube G3 light engines, only a partial amount of the introduced electrical power has to be dissipated through the back of the light engine. The thermal power that has to be dissipated for PrevaLED® Cube G3 light engines is given below.

4.1 Thermal power values

Product reference Rated input current [mA]

Typical thermal power at rated input current [W]*

Max. thermal power at rated input current [W]*

Max. allowable thermal resistance at rated input current (Rth [K/W])**

PL-CUBE-1100-827-G3 394 5.3 6.2 13.2

PL-CUBE-1100-830-G3 371 4.8 5.6 13.5

PL-CUBE-1100-835-G3 371 4.8 5.6 13.5

PL-CUBE-1100-840-G3 371 4.8 5.6 13.5

PL-CUBE-2000-827-G3 476 9.5 11.1 7.3

PL-CUBE-2000-830-G3 449 8.7 10.2 7.5

PL-CUBE-2000-835-G3 449 8.7 10.2 7.5

PL-CUBE-2000-840-G3 449 8.7 10.2 7.5

PL-CUBE-3000-827-G3 733 15.2 17.7 4.8

PL-CUBE-3000-830-G3 690 13.9 16.2 5.0

PL-CUBE-3000-835-G3 690 13.9 16.2 5.0

PL-CUBE-3000-840-G3 690 13.9 16.2 5.0

* Value measured at the tc point at a reference temperature of 75 °C** Value measured on the back of the luminaire at an ambient temperature of 25 °C

For example: A 3 000-lm module can be driven up to 1 050 mA as long as the temperature at the tc point is maintained below 85 °C. The same module should be driven with reduced current if higher case temperatures are desired. In this case, the drive current should not exceed 900 mA at 90 °C.

Note: The lifetime for rated currents and different temperatures are described in the table in chapter 5.2 “Lifetime”. The lifetime will be reduced if the current exceeds rated currents.

4.2 Operating current as a function of temperature

The above chart indicates the maximum drive currents including ripple at a desired temperature at the tc point.

Maximum rated currents vs. temperature

l max [mA]

70

0

400

600

800

1000

1200

75 80 85 90 95

90; 612

85; 1050

90; 900

90; 65085; 750

tc [°C]

1100 lm 2000 lm 3000 lm

200

Page 12: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Thermal considerations

12

4.4 TIM and other accessoriesWhen mounting a PrevaLED® Cube G3 light engine within a luminaire, it is recommended to use thermal interface material (TIM) between the back of the light engine and the luminaire housing or heat sink. It is recommended to use thermal paste. In order to balance possible unevenness, the material should be applied as thinly as possible, but as thickly as necessary. In this way, air inclusions, which may otherwise occur, are replaced by TIM and the required heat conduction between the back of the light engine and the contact surfaces of the luminaire housing is achieved.For this purpose, the planarity and roughness of the surface should be optimized.

The list below is a selection of suppliers of thermal interface materials. Additional suppliers for thermal management support can also be found via OSRAM’s LED Light for You network at www.ledlightforyou.com or at www.osram.com.

Thermal interface materials

Company Website

Alfatec www.alfatec.de

Kerafol www.kerafol.de

Laird www.lairdtech.com

Bergquist www.bergquistcompany.com

Arctic Silver www.arcticsilver.com

Wakefield www.wakefield.com

4.3 Thermal protection featuresTo achieve the best possible lifetime of the LED module and to save it from damage by overheating, thermal protec-tion features have been integrated. The thermal protection of the PrevaLED® Cube G3 LED module is divided into two parts:

The first part of the thermal protection is a thermal derat-ing function that works in combination with LED drivers with LEDset2 functionality. It protects the LED module from overheating by communicating with the LED driver (the LEDset port of the LED module must be connected to the LED driver). The system reduces the current of the LED module if critical temperatures are reached. This results in the best possible performance and lifetime of the LED module. The characteristic of the thermal derating function is shown in the graph “Thermal derating with LEDset2”.

The second part is a reversible onboard thermal fuse that prevents the module from damage by overheating. This feature does not require LEDset2. If the temperature at the tc point exceeds the maximum allowed value by approx. 20 °C, the thermal fuse is triggered and the module shuts off completely. The thermal fuse can be reset by discon-necting the mains and repowering. The characteristic of the shut-off is shown in the graph “Thermal shut-off without LEDset2”.

The behavior below 50 % of the system current depends on the nominal system current and the applied LED driver.

tc [°C]

tc max 105

Current [% of minimal LED driver current]

0

100

50

Thermal derating with LEDset2

tc [°C]102 116

110

Current [% of minimal LED driver current]

0

100

Thermal shut-off without LEDset2

Page 13: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Thermal considerations

13

4.5 Cooling system and heat sink For the selection of a suitable heat sink, several points regarding thermal resistance have to be considered.The selection is usually carried out through the following necessary steps.

Notes: A thermal design must always be confirmed by performing a thermal measurement in steady-state condition. The whole area of the PCB must be in full contact with the heat sink.

The list below is a selection of suppliers of different cooling solutions.

Supplier of active and passive cooling systems

Company Website

Nuventix www.nuventix.com

Sunon www.sunon.com

Cooliance www.cooliance.eu

AVC www.avc-europa.de

SEPA www.sepa-europe.com

Wakefield-Vette www.wakefield-vette.com

Fischer Elektronik www.fischerelektronik.de

Wakefield www.wakefield.com

MechaTronix www.mechatronix-asia.com

Define boundaryconditions

Estimate heat sink

thermal resistance on LED module level

Select heat sink thermal resistance

Total power dissipation of the LED module, max. ambient temperature ta, max. reference temperature tr according to lifetime requirements

Use the estimated Rth as a target for a possible heat sink profile and examine the perfor-mance curve in the heat sink manufacturer’s catalog.

Rth =tr - ta

Pth

tr measured at the tc point

4.6 tc point location and temperature measurementThe tc point is the location where to check if the chosen cooling solution (heat sink) is sufficient to ensure the LED module performance. The tc point is located on the back of the LED module under the center of the light-emitting surface (see following image).

To enable a lifetime of 50 000 (L70B50), the reference temperature (tr) at the tc point must not exceed 80 °C. The maximum temperature reached at the tc point must not exceed 90 °C. A correct temperature measurement can, for example, be performed with a thermocouple.

37.3

41.4

All figures in mm

tc point

Location of the tc point

Page 14: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Thermal considerations

14

4.7 ThermocoupleUse a thermocouple that can be glued onto the LED module. Make sure that the thermocouple is fixed with direct contact to the tc point. Examples of suitable thermocouples:

Notes:Please keep in mind that you need a direct contact between the thermocouple and the PCB. If you use TIM, you should cut out a small area where the thermocouple has direct con-tact to the PCB.

Different thermocouples

Illustration Description Temperature range [°C]

PVC-insulated thermo couple

-10 … +105

PFA-insulated thermo couple

-75 … +260

Sprung thermo couple

-75 … +260

To measure the temperature and to ensure a good thermal coupling between the LED module and the heat sink, you should drill a hole into the heat sink and push the thermo- couple through it. To ensure a direct contact between the thermocouple and the PCB, it is recommended to glue the thermocouple onto the PCB. You can, for example, use an acrylic adhesive (e.g. type Loctite 3751).

It is also possible to use a sprung thermocouple. A suitable type is: Electronic Sensor FS TE-4-KK06/09/2m. Please note that a good thermal contact between the thermo- couple and the PCB is required. Please refer to the data- sheet and the application guideline of the manufacturer to ensure correct handling.

Another possible way is to create a small groove along the top surface of the heat sink and run the thermocoupleto the tc point inside the groove.

K-type thermocouple with miniature connector

Mounting of a PFA-insulated thermocouple by means of a groove

Mounting of a thermocouple through a hole in the heat sink

Page 15: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Lifetime and thermal behavior

15

5 Lifetime and thermal behavior 5.1 Luminous flux as a function of temperatureThe following diagrams show the behavior of the luminous flux output as a function of the temperature at the tc point for PrevaLED® Cube G3.

PL-CUBE-2000-G3PL-CUBE-1100-G3

PL-CUBE-3000-G3

Flux normalized at rated current [%]

-20

90

95

100

105

110

115

30 80 130

tc [°C]

Flux normalized at rated current [%]

-20 0 20 100 120806040

tc [°C]

90

95

100

105

110

115

Flux normalized at rated current [%]

-20

90

95

100

105

110

115

30 80 130

tc [°C]

Page 16: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Lifetime and thermal behavior

16

5.2 LifetimeThe performance of PrevaLED® Cube G3 light engines is measured at a typical tc of 75 °C. The maximum tempera-ture at the tc point must not exceed 80 °C to achieve the expected lifetime (L70B50) of 50 000 hours. The maximum temperature at the tc point to cover the operational warranty of the light engine is 90 °C. A warranty of 5 years can only be given if the light engine is not operated above a tc point temperature of 75 °C. Please note that as the tc in-creases, the lifetime of PrevaLED® Cube G3 light engines decreases. Moreover, the failure rate will also increase.

PL-CUBE-DC-1100-G3

L70B10 L70B50 L80B10 L80B50 L0C10 L0C50 L70F10 L70F50 L80F10 L80F50

Lifetime [h] at tc point = 70 °C 49000 50000 32000 46000 >130000 >130000 49000 50000 32000 46000

Lifetime [h] at tc point = 75 °C 43000 50000 28000 40000 >130000 >130000 42000 50000 28000 40000

Lifetime [h] at tc point = 80 °C 38000 50000 25000 35000 >130000 >130000 37000 50000 25000 35000

Lifetime [h] at tc point = 85 °C 33000 49000 22000 31000 >130000 >130000 33000 49000 22000 31000

Lifetime [h] at tc point = 90 °C 29000 43000 19000 27000 >130000 >130000 29000 43000 19000 27000

PL-CUBE-DC-2000-G3

L70B10 L70B50 L80B10 L80B50 L0C10 L0C50 L70F10 L70F50 L80F10 L80F50

Lifetime [h] at tc point = 70 °C 49000 50000 32000 46000 >130000 >130000 49000 50000 32000 46000

Lifetime [h] at tc point = 75 °C 43000 50000 28000 40000 >130000 >130000 42000 50000 28000 40000

Lifetime [h] at tc point = 80 °C 38000 50000 25000 35000 >130000 >130000 37000 50000 25000 35000

Lifetime [h] at tc point = 85 °C 33000 49000 22000 31000 >130000 >130000 33000 49000 22000 31000

Lifetime [h] at tc point = 90 °C 29000 43000 19000 27000 >130000 >130000 29000 43000 19000 27000

PL-CUBE-DC-3000-G3

L70B10 L70B50 L80B10 L80B50 L0C10 L0C50 L70F10 L70F50 L80F10 L80F50

Lifetime [h] at tc point = 70 °C 44000 50000 29000 42000 >130000 >130000 44000 50000 29000 42000

Lifetime [h] at tc point = 75 °C 39000 50000 25000 36000 >130000 >130000 38000 50000 25000 36000

Lifetime [h] at tc point = 80 °C 34000 50000 22000 32000 >130000 >130000 34000 50000 22000 32000

Lifetime [h] at tc point = 85 °C 30000 44000 20000 28000 >130000 >130000 30000 44000 19000 28000

Lifetime [h] at tc point = 90 °C 26000 39000 17000 25000 >130000 >130000 26000 39000 17000 25000

Page 17: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Mechanical considerations

17

6 Mechanical considerationsThe following schematic drawing provides further details on the dimensions of PrevaLED® Cube G3 LED modules. For3D files of the LED modules, please go to www.osram.com.

6.1 Outline drawing

6.2 3D drawing

Move me!Movable 3D PrevaLED® Cube G3 LED module (works with Adobe Acrobat 7 or higher)

6.3 Mechanical protection of the light engineThe housing of a PrevaLED® Cube G3 LED module should not be exposed to strong mechanical stress. Please apply force only to the dedicated mounting posi-tions. Strong mechanical stress can lead to irreversible damage of the LED module.

For operation in damp, wet or dusty environments, the user has to make sure that an adequate ingress protection (IP) is chosen. The LED module has to be protected by a suitable IP rating of the luminaire housing. Please consider the lumi-naire standard IEC 60598-1 as well as the different require-ments for indoor and outdoor application.

kg

6.4 Mounting To fix a PrevaLED® Cube G3 light engine to a heat sink, you may use M4 cylinder head screws according to DIN 912 or ISO 4762. The recommended torque is 1.0 ± 0.5 Nm.

Note:General mechanical tolerances according to ISO 2768 c.

Mount the LED module from the top

61

4.3

68

37.3

41.4

Tc

82.8

81.6

21.1

18.6

54.4

6.2 (screw contact area)

All figures in mm

Page 18: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

PrevaLED® Cube G3 LED modules | Norms and standards

18

7 Norms and standardsSafety: IEC/EN 62031 UL 8750 Class 2

Photobiological safety: IEC/EN 62471 Risk group 1

Ingress protection: IP20 (no ingress protection without housing)

Approvals: CE, UL, VDE ENEC

DisclaimerAll information contained in this document has been col-lected, analyzed and verified with great care by OSRAM. However, OSRAM is not responsible for the correctness and completeness of the information contained in this document and OSRAM cannot be made liable for any damage that occurs in connection with the use of and/or reliance on the content of this document. The information contained in this document reflects the current state of knowledge on the date of issue.

Page 19: · PrevaLED® Cube G3 LED modules | Optical considerations 5 2.3 Color temperature The PrevaLED® Cube G3 series is currently available in 2 700 K, 3 000 K, 3 500 K and 4 000 K. The

www.osram.com/prevaled

OSRAM GmbH

Head office:

Marcel-Breuer-Strasse 6

80807 Munich, Germany

Phone +49 89 6213-0

Fax +49 89 6213-2020

www.osram.com

03/1

6 O

SR

AM

LLS

SS

L-O

EM

-EM

Sub

ject

to

chan

ge w

ithou

t no

tice.

Err

ors

and

om

issi

ons

exce

pte

d.


Recommended