+ All Categories
Home > Documents > Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with...

Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with...

Date post: 25-Jun-2018
Category:
Upload: truongque
View: 214 times
Download: 0 times
Share this document with a friend
56
Price List effective from April 1, 2010
Transcript
Page 1: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

Price Listeffective from April 1, 2010

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:00 Page 1

Page 2: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

Air to Water Heating ProductsEstia Air to Water Heat Pump 3

Residential and Light Commercial Products (RAS)RAS Inverter High- Wall Unit (AvAnt) 4RAS Daiseikai High-Wall Units 5RAS Inverter Bi Flow 6RAS Inverter Multi-Split Systems – High- Wall (AvAnt) 7RAS Inverter Multi-Split Systems – High- Wall (Daiseikai) 8RAS Inverter Multi-Split Systems – Bi Flow Console 9RAS Inverter Multi-Split Systems – Compact Cassette 10RAS Inverter Multi-Split Systems – Ducted Unit 11RAS Multi combination table 12

Light Commercial Products (RAV) Digital Inverter 4 Way Cassette 15Digital Inverter Compact 4 Way Cassette 16Digital Inverter Ducted Unit 17Digital Inverter Slim Ducted Unit 18Digital Inverter High-Wall 19Digital Inverter Ceiling Suspended Unit 20Digital Inverter Console Unit 21Digital Inverter Twin-Split Systems 22Digital Inverter Triple-Split Systems 23Large Capacity Digital Inverter 24-27Super Digital 4 Way Cassette 28Super Digital Inverter Compact 4 Way Cassette 29Super Digital Inverter Ducted Unit 30Super Digital Inverter Slim Ducted Unit 31Super Digital Inverter High-Wall 32Super Digital Inverter Ceiling Suspended Unit 33Super Digital Inverter Twin-Split Systems 34

Variable Refrigerant Flow Products Super-Modular Multi System (SMMS) - Outdoor Unit 35Super-Modular Multi System (SMMS) – Fresh Air Intake Unit 36Super-Heat Recovery Multi System (SHRM) - Outdoor Unit 37MiNi-SMMS System – Outdoor Units 38VRF Indoor Unit – 4 Way Cassette 39VRF Indoor Unit – Compact 4 Way Cassette 40VRF Indoor Unit – 2 Way Cassette 41VRF Indoor Unit – 1 Way Cassette 42VRF Indoor Unit – Slim Ducted Unit 43VRF Indoor Unit – Standard Ducted Unit 44VRF Indoor Unit – Ceiling Suspended Unit 45VRF Indoor Unit – High Static Ducted Unit 46VRF Indoor Unit – High Wall Units 47VRF Indoor Unit – Floor Mounted Console Unit 48VRF Indoor Unit – Concealed Chassis Unit 49VRF Indoor Unit – Floor Mounted Cabinet Unit 50

Ancillary Products Air to Air Heat Exchanger 51Air Handling Unit Applications 52

Controls and Accessories 53-55

Product Index

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:00 Page 2

Page 3: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

3

Estia Air to Water Heat Pump

• Two zone heating control

• Sanitary hot water production

• Built in electric heater back-up

• Outdoor unit 240V, 1 phase supply

• Hydro module single and three phase options

• High efficiency twin rotary inverter

compressor

• Light weight and easy to Install

• Optional interlock with back-up boiler

• Bespoke ‘Easy to Use’ Controller

Outdoor Model HWS- 802H-E 1102H-E 1402H-E

Heating Capacity kW 8.00 11.20 14.00Power Input kW 1.96 2.40 3.15COP W/W 4.08 4.66 4.45Cooling Capacity kW 6.00 10.00 11.00Power Input kW 2.13 3.52 4.08EER W/W 2.82 2.84 2.69Power Supply V, Hz 220/240-1-50 220/240-1-50 220/240-1-50Sound Pressure (@1.5m) db(A) 48 49 51

Pipe Length (max/min) m 30/5 30/3 30/3Max Height Separation m 30 30 30Pipe Size in 3/8 & 5/8 3/8 & 5/8 3/8 & 5/8Run Current A 20.8 22.8 22.8Start Current A 1 1 1Suggested Fuse A 25 25 25

Retail price

£ 1845.- 2037.- 2397.-

Hydro Unit Model HWS- 802XWHM3-E 802XWHT6-E 1402XWHM3-E 1402XWHT6-E 1402XWHT9-E

Electric Heater Backup kW 1 Phase 230V 3kW 3 Phase 400V 6kW 1 Phase 230V 3kW 3 Phase 400V 6kW 3 Phase 400V 9kWLeaving Water Temperature °C ~ Heat 20 to 55 20 to 55 20 to 55 20 to 55 20 to 55

°C ~ Cool 10 to 30 10 to 30 10 to 30 10 to 30 10 to 30Sound Pressure (@1m) db(A) 27 27 29 29 29Max Current A 13 15 13 15 23Suggested Fuse A 16 25 16 25 25

Retail price

Hydro unit £ 2770.- 2878.- 3645.- 3758.- 3777.-

Hot Water Cylinder HWS- 1501CSHM3-UK 2101CSHM3-UK 3001CSHM3-UK

Water Volume Litres 150 210 300Max Water Temp °C 70 70 70Electric Heater kW 2.75 2.75 2.75Power Supply V 220/240-1-50 220/240-1-50 220/240-1-50Max Current A 12 12 12Suggested Fuse A 16 16 16

Retail price

Hot water cylinder £ 830.- 970.- 1135.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:00 Page 3

Page 4: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

RAS Inverter High-Wall Unit (AvAnt)

• A class in cooling and heating (sizes 10 and13)

• Enhanced and slimline flat-panel design

• Extremely low sound level

• Easy installation and maintenance

• Auto-diagnosis function

• 3 in 1 air filtration system

• Latest digital hybrid inverter technology

• Easy to use remote control with extra-large

display

4

Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3Outdoor unit RAS-107SAV-E3 RAS-137SAV-E3 RAS-167SAV-E3Remote control (included) Infra-red Infra-red Infra-red

Cooling capacity (range) kW 1.1/2.5/3.0 1.1/3.5/4.0 1.1/4.4/5.0Heating capacity (range) kW 0.9/3.2/4.1 0.9/4.2/5.0 1.0/5.2/6.2Power input, cooling/heating kW 0.76/0.87 1.08/1.14 1.56/1.52EER, cooling/COP heating W/W 3.29/3.68 3.24/3.68 2.82/3.42Annual power consumption, cooling kWh 380 540 780Energy label, cooling/heating A/A A/A C/B

UK conditions - cooling capacity kW tbc tbc tbcUK conditions - sensible cooling capacity kW tbc tbc tbcUK conditions - heating capacity kW tbc tbc tbc

Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3

Air flow, cooling (high) l/s 145 158 192Air flow, cooling (high) m3/h 522 570 690Air flow, heating (high) l/s 160 173 207Air flow, heating (high) m3/h 576 624 744

Sound power level, high dB(A) 53 53 58Sound pressure level, low/medium/high dB(A) 30/35/40 28/34/40 31/40/45

Dimensions. height x width x depth mm 250 x 740 x 195 275 x 790 x 205 275 x 790 x 205

Weight kg 8 9 9

Outdoor unit RAS-107SAV-E3 RAS-137SAV-E3 RAS-167SAV-E3

Air flow l/s (m3/h) 450 (1620) 625 (2250) 625 (2250)

Sound power level, cooling/heating dB(A) 61/63 61/63 62/63Sound pressure level, cooling/heating dB(A) 48/50 48/50 49/50

Dimensions, height x width x depth mm 530 x 660 x 240 550 x 780 x 290 550 x 780 x 290Weight kg 27 33 40

Operating range, cooling/heating °C 15 to 43/-10 to 24 -10 to 40/-15 to 24 -10 to 46/-15 to 24

Pipe connections, gas - liquid in 3/8 - 1/4 3/8 - 1/4 1/2 - 1/4Pipe length, maximum m 10 20 20Pipe length, pre-charged m 10 15 15Maximum height difference (above/below) m 8 10 10

Max. operating current (cooling 240 V) A 4.0 5.2 7.2Suggested fuse size A 6 6 10Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E

Retail price

Indoor unit £ 202.- 208.- 226.-Outdoor unit £ 478.- 587.- 714.-System price £ 680.- 795.- 940.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:00 Page 4

Page 5: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

5

Outdoor unit RAS-10SAVP-E RAS-13SAVP-E RAS-16SAVP-EIndoor unit RAS-B10SKVP-E RAS-B13SKVP-E RAS-B16SKVP-ERemote control (included) Infra-red Infra-red Infra-red

Cooling capacity (range) kW 2.5 (0.5-3.5) 3.5 (0.6-4.5) 4.5 (0.8-5.0)Heating capacity (range) kW 3.2 (0.6-6.1) 4.2 (0.6-6.9) 5.5 (0.8-8.0)Power input, cooling/heating kW 0.49/0.63 0.85/0.95 1.35/1.49EER cooling/COP heating W/W 5.05/5.10 4.12/4.42 3.33/3.69Annual power consumption, cooling kWh 245 425 675Energy label, cooling/heating A/A A/A A/A

UK conditions - cooling capacity kW 3.30 4.07 4.50UK conditions - sensible cooling capacity kW 2.48 3.05 3.38UK conditions - heating capacity kW 4.62 4.91 5.80

Indoor unit RAS-B10SKVP-E RAS-B13SKVP-E RAS-B16SKVP-E

Air flow, cooling (high/low) l/s (m3/h) 152/77 (546/276) 153/77 (564/276) 168/88 (606/318)Air flow, heating (high/low) l/s (m3/h) 170/78 (612/282) 177/53 (636/300) 188/95 (678/342)

Sound pressure level, high/low cooling - heating dB(A) 42/27 - 43/27 43/27 - 44/27 45/29 - 45/29Sound power level, high/low cooling - heating dB(A) 57/42 - 58/42 58/42 - 59/42 60/44 - 60/45

Dimensions, height x width x depth mm 250 x 790 x 208 250 x 790 x 208 250 x 790 x 208Weight kg 9 9 9

Outdoor unit RAS-10SAVP-E RAS-13SAVP-E RAS-16SAVP-E

Air flow l/s (m3/h) 597 (2149) 669 (2408) 669 (2408)

Sound pressure level, cooling/heating dB(A) 46/47 48/50 49/50Sound power level, cooling/heating dB(A) 59/60 61/63 62/63

Dimensions, height x width x depth mm 550 x 780 x 290 550 x 780 x 290 550 x 780 x 290Weight kg 38 38 38

Operating range, cooling °C -10 to 46°C -10 to 46°C -10 to 46°COperating range, heating °C -15 to 24°C -15 to 24°C -15 to 24°C

Pipe connections, gas - liquid in 3/8 - 1/4 3/8 - 1/4 1/2 - 1/4Pipe length, maximum/minimum m 25/2 25/2 25/2Pipe length, pre-charged m 15 15 15Additional R-410A charge g/m 20 20 20

Max. height difference m 10 10 10

Max. operating current (cooling 240 V) A 2.49 3.9 5.9Suggested fuse size A 6 6 10Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E

Retail price

Indoor unit £ 368.- 368.- 380.-Outdoor unit £ 670.- 830.- 1100.-System price £ 1038.- 1198.- 1480.-

RAS Super Daiseikai High-Wall Units

• New elegant and compact design

• DC hybrid inverter with twin rotary compressors

• Superior indoor air quality

• Advanced and extensive air purification

• All units rated A for energy efficiency

• Quiet operation for enhanced user comfort

• Ag + Plasma Air Purifier

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:00 Page 5

Page 6: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

6

RAS Inverter Bi Flow Console

• Bi-flow (two outlets for flow intensity and airdirection)

• Fits perfectly under the window sill or in a low

ceiling attic

• Unique floor heating function

• New IAQ filter filtration system

• Easy to use command control interface on unit(includes child lock)

• Auto-diagnosis function

• Latest digital hybrid inverter technology

• Easy to use remote control with extra-largedisplay

Indoor unit RAS-B10UFV-E RAS-B13UFV-E RAS-B18UFV-EOutdoor unit RAS-10SAV2-E RAS-13SAV2-E RAS-18SAV2-ERemote control (included) Infra-red Infra-red Infra-red

Cooling capacity (range) kW 1.1/2.5/3.1 1.1/3.5/4.1 1.0/5.0/5.7Heating capacity (range) kW 1.0/3.2/4.8 1.0/4.2/5.4 1.1/5.8/6.3Power input, cooling/heating kW 0.6/0.75 0.97/1.13 1.66/1.81EER, cooling/COP heating W/W 4.2/4.27 3.61/3.73 3.01/3.21Annual power consumption, cooling kWh 298 485 830Energy label, cooling/heating A/A A/A B/C

UK conditions - cooling capacity kW tbc tbc tbcUK conditions - sensible cooling capacity kW tbc tbc tbcUK conditions - heating capacity kW tbc tbc tbc

Indoor unit RAS-B10UFV-E RAS-B13UFV-E RAS-B18UFV-E

Air flow, cooling (high) l/s 130 140 170Air flow, cooling (high) m3/h 467 509 602Air flow, heating (high) l/s 140 150 180Air flow, heating (high) m3/h 509 550 644

Sound power level, low/high dB(A) 38/54 39/55 47/61Sound pressure level, low/high dB(A) 23/39 24/40 32/46

Dimensions. height x width x depth mm 600 x 700 x 220 600 x 700 x 220 600 x 700 x 220

Weight kg 16 16 16

Outdoor unit RAS-10SAV2-E RAS-13SAV2-E RAS-18SAV2-E

Air flow l/s (m3/h) 500 (1800) 625 (2250) 532 (1914)

Sound power level, cooling/heating dB(A) 59/60 61/63 64/65Sound pressure level, cooling/heating dB(A) 46/47 48/50 49/50

Dimensions, height x width x depth mm 550 x 780 x 290 550 x 780 x 290 550 x 780 x 290Weight kg 33 33 39

Operating range, cooling/heating °C -10 to 46/-15 to 24 -10 to 46/-15 to 24 -10 to 46/-15 to 24

Pipe connections, gas - liquid in 3/8 - 1/4 3/8 - 1/4 1/2 - 1/4Pipe length, maximum m 20 20 20Pipe length, pre-charged m 15 15 15Maximum height difference (above/below) m 10 10 10

Max. operating current (cooling 240 V) A 3.5 4.9 7.2Suggested fuse size A 6 6 10Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E

Retail price

Indoor unit £ 550.- 600.- 665.-Outdoor unit £ 520.- 640.- 865.-System price £ 1070.- 1240.- 1530.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:00 Page 6

Page 7: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

Indoor unit, high-wall type RAS-M10SKV-E RAS-M13SKV-E RAS-M16SKV-ERemote control (included) Infra-red Infra-red Infra-red

Nominal cooling capacity kW 2.5 3.5 4.5Nominal heating capacity kW 3.2 4.2 5.2

UK conditionsCooling capacity kW 2.60 3.50 4.32Sensible cooling capacity kW 2.16 2.96 3.60Heating capacity kW 3.70 4.60 5.05

Air flow (coolg./heatg.) l/s (m3/h) 145/160 (522/576) 156/175 (563/630) 192/206 (691/743)

Sound pressure (h/l - c/h) dB(A) 38/29-40/30 39/26-40/28 45/30-45/31Sound power (h/l - clg/htg) dB(A) 51/42-53/43 52/39-53/41 58/43-58/44

Dimensions, H x W x D mm 275 x 790 x 208 275 x 790 x 208 275 x 790 x 208Weight kg 10 10 10

Retail price

1 x Indoor unit £ 227.- 240.- 268.-

Outdoor unit RAS-M14GAV-E RAS-M18GAV-E RAS-3M26GAV-E RAS-4M27GAV-E RAS-5M34UAV-E

Number of indoor units 2-room multisplit 2-room multisplit 3-room multisplit 4-room multisplit 5-room multisplit

EER/COP (cooling/heating) W/W 3.70/4.35 3.25/3.62 3.33/3.53 3.20/4.00 3.42/4.24

Air flow l/s (m3/h) 505 (1820) 583 (2100) 833 (3000) 833 (3000) TBC

Sound pressure level, clg./htg. dB(A) 48/46 50/48 48/48 48/48 51/54Sound power level, clg./htg. dB(A) 61/59 63/61 61/61 61/61 66/69

Dimensions, H x W x D mm 550 x 780 x 290 550 x 780 x 290 795 x 900 x 320 795 x 900 x 320 890 x 900 x 320

Weight kg 36 40 64 65 75

Operating range, coolg./heatg. °C 5 to 43/-15 to 24 5 to 43/-15 to 24 10 to 43/-15 to 21 10 to 43/-15 to 21 10 to 43/-10 to 22

Pipe connections gas - liquid in 3/8 - 1/4 3/8 - 1/4 3/8 - 1/4 1/2 - 1/4 TBCPipe length, max. (unit/total) m 20/30 20/30 25/50 25/70 25/80Pipe length, pre-charged m 20 20 50 70 40Max. height difference m 10 10 15 15 15

Max. operating current, cooling A 6.9 7.2 10.8 10.6 TBCSuggested fuse size A 10 10 16 16 TBCPower supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor UnitInterconnecting cables 3 + E 3 + E 3 + E 3 + E 3 + E

Retail price

Outdoor unit £ 912.- 1012.- 1660.- 2055.- 2380.-

7

• Modern flat-panel design

• Easy installation and maintenance

• Easy-to-use remote control with extra-largedisplay

• Five selectable fan speeds

• Five fixed louvre positions, swing and automode

• Extremely low noise levels

• Controller memorises favourite user settings

• Superior five-stage air filtration system

• Latest digital hybrid inverter technology

• Designed for use with refrigerant R410A

RAS Multi-Split Inverter High-Wall Units

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:00 Page 7

Page 8: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

8

RAS Multi-Split Inverter Super Daiseikai High-Wall Units

• New elegant and compact design

• DC hybrid inverter with twin rotary compressors

• Superior indoor air quality

• Single or multi-split system

• Advanced and extensive air purification

• All units rated A for energy efficiency

• Quiet operation for enhanced user comfort

• Ag + Plasma Air Purifier

Indoor unit RAS-B10SKVP-E RAS-B13SKVP-E RAS-B16SKVP-ERemote control (included) Infra-red Infra-red Infra-red

Cooling capacity (range) kW 2.5 3.5 4.5Heating capacity (range) kW 3.2 4.2 5.5

UK conditionsCooling capacity kW 2.60 3.50 4.32Sensible cooling capacity kW 2.16 2.96 3.60Heating capacity kW 3.70 4.60 5.05

Air flow, cooling (h/m/l) l/s (m3/h) 157/106/81 (562/381/292) 163/109/81 (588/394/292) 181/120/91 (653/432/328)Air flow, heating (h/m/l) l/s (m3/h) 176/136/81 (632/490/292) 182142//81 (654/511/292) 189/161/91 (681/580/328)

Sound pressure level* dB(A) 42/25 - 43/25 43/26 - 44/26 45/28 - 45/28Sound power level* dB(A) 55/38 - 56/38 56/39 - 57/39 58/41 - 58/41

Dimensions, H x W x D mm 250 x 790 x 215 250 x 790 x 215 250 x 790 x 215Weight kg 9 9 9

Retail price

Indoor unit £ 368.- 368.- 380.-

Outdoor unit RAS-M14GAV-E RAS-M18GAV-E RAS-3M26GAV-E RAS-4M27GAV-E RAS-5M34UAV-E

Number of indoor units 2-room multisplit 2-room multisplit 3-room multisplit 4-room multisplit 5-room multisplit

EER/COP (cooling/heating) W/W 3.70/4.35 3.25/3.62 3.33/3.53 3.20/4.00 3.42/4.24

Air flow l/s (m3/h) 505 (1820) 583 (2100) 833 (3000) 833 (3000) TBC

Sound pressure level, clg./htg.** dB(A) 48/46 50/48 48/48 48/48 51/54Sound power level, clg./htg.** dB(A) 61/59 63/61 61/61 61/61 66/69

Dimensions, H x W x D mm 550 x 780 x 290 550 x 780 x 290 795 x 900 x 320 795 x 900 x 320 890 x 900 x 320

Weight kg 36 40 64 65 75

Operating range, coolg./heatg. °C 5 to 43/-15 to 24 5 to 43/-15 to 24 10 to 43/-15 to 24 10 to 43/-15 to 24 10 to 43/-10 to 22

Pipe connections gas - liquid in 3/8 - 1/4 3/8 - 1/4 3/8 - 1/4 1/2 - 1/4 TBCPipe length, max. (unit/total) m 20/30 20/30 25/50 25/70 25/80Pipe length, pre-charged m 20 20 50 70 40Max. height difference m 10 10 15 15 15

Max. operating current, cooling A 6.9 7.2 10.8 10.8 TBCSuggested fuse size A 10 10 16 16 TBCPower supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E 3 + E 3 + E

* high/low, cooling - heating** For indoor unit size 10

Retail price

Outdoor unit £ 912.- 1012.- 1660.- 2055.- 2380.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 8

Page 9: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

9

RAS Multi Split Inverter Bi Flow Console Units

• Bi-flow (two outlets for flow intensity and airdirection)

• Fits perfectly under the window sill or in a low

ceiling attic

• Unique floor heating function

• New IAQ filter filtration system

• Easy to use command control interface on unit(includes child lock)

• Auto-diagnosis function

• Latest digital hybrid inverter technology

• Easy to use remote control with extra-largedisplay

Indoor unit RAS-B10UFV-E RAS-B13UFV-E RAS-B18UFV-ERemote control (included) Infra-red Infra-red Infra-red

Cooling capacity (range) kW 2.5 3.5 5.0Heating capacity (range) kW 3.2 4.2 5.8

UK conditions - cooling capacity kW tbc tbc tbcUK conditions - sensible cooling capacity kW tbc tbc tbcUK conditions - heating capacity kW tbc tbc tbc

Air flow, cooling (high) l/s 130 140 170Air flow, cooling (high) m3/h 467 509 602Air flow, heating (high) l/s 140 150 180Air flow, heating (high) m3/h 509 550 644

Sound power level, low/high dB(A) 38/54 39/55 47/61Sound pressure level, low/medium/high dB(A) 23/39 24/40 32/46

Dimensions. height x width x depth mm 600 x 700 x 220 600 x 700 x 220 600 x 700 x 220

Weight kg 16 16 16

Retail price

Indoor unit £ 550.- 600.- 665.-

Outdoor unit RAS-M14GAV-E RAS-M18GAV-E RAS-3M26GAV-E RAS-4M27GAV-E RAS-5M34UAV-E

Number of indoor units 2-room multisplit 2-room multisplit 3-room multisplit 4-room multisplit 5-room multisplit

EER/COP (cooling/heating) W/W 3.70/4.35 3.25/3.62 3.33/3.53 3.20/4.00 3.42/4.24

Air flow l/s (m3/h) 505 (1820) 583 (2100) 833 (3000) 833 (3000) TBC

Sound pressure level, clg./htg.** dB(A) 48/46 50/48 48/48 48/48 51/54Sound power level, clg./htg.** dB(A) 61/59 63/61 61/61 61/61 66/69

Dimensions, H x W x D mm 550 x 780 x 290 550 x 780 x 290 795 x 900 x 320 795 x 900 x 320 890 x 900 x 320

Weight kg 36 40 64 65 75

Operating range, coolg./heatg. °C 5 to 43/-15 to 24 5 to 43/-15 to 24 10 to 43/-15 to 24 10 to 43/-15 to 24 10 to 43/-10 to 22

Pipe connections gas - liquid in 3/8 - 1/4 3/8 - 1/4 3/8 - 1/4 1/2 - 1/4 TBCPipe length, max. (unit/total) m 20/30 20/30 25/50 25/70 25/80Pipe length, pre-charged m 20 20 50 70 40Max. height difference m 10 10 15 15 15

Max. operating current, cooling A 6.9 7.2 10.8 10.8 TBCSuggested fuse size A 10 10 16 16 TBCPower supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E 3 + E 3 + E

* high/low, cooling - heating** For indoor unit size 10

Retail price

Outdoor unit £ 912.- 1012.- 1660.- 2055.- 2380.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 9

Page 10: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

10

Indoor unit, cassette type RAS-M10SMUV-E RAS-M13SMUV-E RAS-M16SMUV-ERemote control (included) Infra-red Infra-red Infra-red

Nominal cooling capacity kW 2.7 3.7 4.5Nominal heating capacity kW 4.0 5.0 5.2

UK conditionsCooling capacity kW 2.30 3.20 4.30Sensible cooling capacity kW 2.08 2.85 3.50Heating capacity kW 3.50 4.50 5.60

Air flow l/s (m3/h) 163 (588) 172 (618) 183 (660)

Sound pressure (high/low) dB(A) 37/30 38/30 40/31Sound power (high/low) dB(A) 52/45 53/45 55/46

Dimensions, H x W x D mm 268 x 575 x 575 268 x 575 x 575 268 x 575 x 575Weight kg 17 17 17

Retail price

1 x Indoor unit £ 827.- 880.- 920.-

Outdoor unit RAS-M18GAV-E RAS-3M26GAV-E RAS-4M27GAV-E RAS-5M34UAV-E

Number of indoor units 2-room multisplit 3-room multisplit 4-room multisplit 5-room multisplit

EER/COP (cooling/heating) W/W 3.25/3.62 3.33/3.53 3.20/4.00 3.42/4.24

Air flow l/s (m3/h) 505 (1820) 833 (3000) 833 (3000) TBC

Sound pressure level, clg./htg.** dB(A) 50/48 48/48 48/48 51/54Sound power level, clg./htg.** dB(A) 63/61 61/61 61/61 66/69

Dimensions, H x W x D mm 550 x 780 x 290 795 x 900 x 320 795 x 900 x 320 890 x 900 x 320

Weight kg 40 64 65 75

Operating range, coolg./heatg. °C 5 to 43/-15 to 24 10 to 43/-15 to 24 10 to 43/-15 to 24 10 to 43/-10 to 22

Pipe connections gas - liquid in 3/8 - 1/4 3/8 - 1/4 1/2 - 1/4 TBCPipe length, max. (unit/total) m 20/30 25/50 25/70 25/80Pipe length, pre-charged m 20 50 70 40Max. height difference m 10 15 15 15

Max. operating current, cooling A 7.2 10.8 10.8 TBCSuggested fuse size A 10 16 16 TBCPower supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E 3 + E

* high/low, cooling - heating** For indoor unit size 10

Retail price

Outdoor unit £ 1012.- 1660.- 2055.- 2380.-

• New compact 600 x 600 mm cassette

• Easy installation and maintenance via cornerpockets

• Multi-split inverter system

• Auto-diagnosis function

• Latest digital hybrid inverter technology

RAS Multi-Split Inverter 600 x 600 mm Cassette Units

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 10

Page 11: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

11

Indoor unit, ducted type RAS-M10GDV-E RAS-M13GDV-E RAS-M16GDV-ERemote control (included) Infra-red Infra-red Infra-red

Nominal cooling capacity kW 2.5 3.5 4.5Nominal heating capacity kW 3.2 4.2 5.2

UK conditionsCooling capacity kW 2.60 3.50 4.32Sensible cooling capacity kW 2.16 2.96 3.60Heating capacity kW 3.70 4.60 5.05

Air flow, cooling (h/l) l/s (m3/h) 200/111 (720/400) 217/119 (781/428) 217/111 (781/428)Air flow, heating (h/l) l/s (m3/h) 200/125 (720/450) 217/133 (781/479) 217/139 (781/500)Sound pressure (h/l - c/h) dB(A) 31/23-31/24 32/24-32/25 33/25-33/28Sound power (h/l - clg/htg) dB(A) 44/36-44/37 45/37-45/38 46/38-46/41

Ext. static pressure (std/max)* Pa 35.3/54.9 41.2/63.7 41.2/63.7

Dimensions, H x W x D mm 230 x 750 x 440 230 x 750 x 440 230 x 750 x 440Weight kg 19 19 19

Retail price

1 x Indoor unit £ 434.- 494.- 591.-

Outdoor unit RAS-M14GAV-E RAS-M18GAV-E RAS-3M26GAV-E RAS-4M27GAV-E RAS-5M34UAV-E

Number of indoor units 2-room multisplit 2-room multisplit 3-room multisplit 4-room multisplit 5-room miltisplit

EER/COP (cooling/heating) W/W 3.70/4.35 3.25/3.62 3.33/3.53 3.20/4.00 3.42/4.24

Air flow l/s (m3/h) 505 (1820) 583 (2100) 833 (3000) 833 (3000) TBC

Sound pressure level, clg./htg. dB(A) 48/46 50/48 48/48 48/48 51/54Sound power level, clg./htg. dB(A) 61/59 63/61 61/61 61/61 66/69

Dimensions, H x W x D mm 550 x 780 x 290 550 x 780 x 290 795 x 900 x 320 795 x 900 x 320 890 x 900 x 320

Weight kg 36 40 64 65 75

Operating range, coolg./heatg. °C 5 to 43/-15 to 24 5 to 43/-15 to 24 10 to 43/-15 to 21 10 to 43/-15 to 21 10 to 43/-10 to 22

Pipe connections gas - liquid in 3/8 - 1/4 3/8 - 1/4 3/8 - 1/4 1/2 - 1/4 TBCPipe length, max. (unit/total) m 20/30 20/30 25/50 25/70 25/80Pipe length, pre-charged m 20 20 50 70 40Max. height difference m 10 10 15 15 15

Max. operating current, cooling A 6.9 7.2 10.8 10.6 TBCSuggested fuse size A 10 10 16 16 TBCPower supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E 3 + E 3 + E

* Static pressure at nominal conditions** Supplied without a filter

Retail price

Outdoor unit £ 912.- 1012.- 1660.- 2055.- 2380.-

RAS Multi-Split Inverter Ducted Units

• High static pressure

• Slim design, only 230 mm high

• Low noise multi-split system

• Flexible air inlet below or at rear

• Drain pump kit (optional extra)

• Auto-diagnosis function

• Latest digital hybrid inverter technology

• Hard-wired remote controller (optional extra)

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 11

Page 12: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

12

Combination ratings (size 14) heat pump

Operating status Cooling HeatingCombination Unit capacity, kW Cooling capacity, kW Unit capacity, kW Heating capacity, kWUnit A Unit B Unit A Unit B Min Rated Max Unit A Unit B Min Rated Max

2 units operating 10 10 1.95 1.95 1.4 3.9 4.4 2.15 2.15 0.9 4.3 4.613 10 2.33 1.67 1.4 4 4.5 2.5 1.9 0.9 4.4 4.7

Combination ratings (size 18) heat pump

Operating status Cooling HeatingCombination Unit capacity, kW Cooling capacity, kW Unit capacity, kW Heating capacity, kWUnit A Unit B Unit A Unit B Min Rated Max Unit A Unit B Min Rated Max

2 units operating 10 10 2.55 2.55 1.4 5.1 6.1 3.2 3.2 0.9 6.4 8.313 10 3.01 2.19 1.4 5.2 6.2 3.72 2.98 0.9 6.7 8.713 13 2.6 2.6 1.4 5.2 6.2 3.35 3.35 0.9 6.7 8.716 10 3.25 1.95 1.4 5.2 6.2 3.88 2.82 0.9 6.7 8.7

Combination ratings (size 3M26) heat pump

Operating status Cooling HeatingCombination Unit capacity, kW Cooling capacity, kW Unit capacity, kW Heating capacity, kWUnit A Unit B Unit C Unit A Unit B Unit C Min Rated Max Unit A Unit B Unit C Min Rated Max

2 units operating 10 10 - 2.7 2.7 - 2.5 5.4 6.3 3.6 3.6 - 1.5 7.2 1013 10 - 3.41 2.49 - 2.7 5.9 6.6 4.22 3.38 - 1.5 7.6 10.116 10 - 3.94 2.36 - 2.9 6.3 6.9 4.57 3.33 - 1.5 7.9 10.113 13 - 3.15 3.15 - 2.9 6.3 6.9 3.95 3.95 - 1.5 7.9 10.116 13 - 3.73 3.07 - 3 6.8 7.2 4.35 3.95 - 1.5 8.3 10.216 16 - 3.6 3.6 - 3.2 7.2 7.5 4.3 4.3 - 1.5 8.6 10.2

3 units operating 10 10 10 2.47 2.47 2.47 3.6 7.4 8.2 2.87 2.87 2.87 2 8.6 10.413 10 10 3.01 2.2 2.2 3.9 7.4 8.3 3.35 2.68 2.68 2 8.7 10.516 10 10 3.36 2.02 2.02 4 7.4 8.5 3.59 2.61 2.61 2 8.8 10.613 13 10 2.71 2.71 1.98 4 7.4 8.5 3.14 3.14 2.51 2 8.8 10.616 13 10 3.1 2.55 1.86 4 7.5 8.6 3.34 3.03 2.43 2 8.8 10.613 13 13 2.5 2.5 2.5 4 7.5 8.6 2.93 2.93 2.93 2 8.8 10.616 16 10 2.88 2.88 1.73 4.1 7.5 8.8 3.26 3.26 2.37 2 8.9 10.716 13 13 2.84 2.33 2.33 4.1 7.5 8.8 3.16 2.87 2.87 2 8.9 10.716 16 13 2.66 2.66 2.19 4.2 7.5 8.9 3.16 3.09 2.81 2 9 10.8

Combination ratings (size 4M27) heat pump

Operating status Cooling HeatingCombination Unit capacity, kW Cooling capacity, kW Unit capacity, kW Heating capacity, kWUnit A Unit B Unit C Unit D Unit A Unit B Unit C Unit D Min Rated Max Unit A Unit B Unit C Unit D Min Rated Max

2 units operating 10 10 - - 2.70 2.70 - - 2.50 5.40 6.30 3.60 3.60 - - 1.50 7.20 10.013 10 - - 3.41 2.49 - - 2.70 5.90 6.60 4.22 3.38 - - 1.50 7.60 10.1016 10 - - 3.94 2.36 - - 2.90 6.30 6.90 4.57 3.33 - - 1.50 7.90 10.1013 13 - - 3.15 3.15 - - 2.90 6.30 6.90 3.95 3.95 - - 1.50 7.90 10.1016 13 - - 3.73 3.07 - - 3.00 6.80 7.20 4.35 3.95 - - 1.50 8.30 10.2016 16 - - 3.60 3.60 - - 3.20 7.20 7.50 4.30 4.30 - - 1.50 8.60 10.20

3 units operating 10 10 10.0 - 2.53 2.53 2.53 - 3.60 7.60 8.20 2.87 2.87 2.87 - 2.0 8.60 10.4013 10 10.0 - 3.13 2.28 2.28 - 3.90 7.70 8.30 3.35 2.68 2.68 - 2.0 8.70 10.5016 10 10.0 - 3.50 2.10 2.10 - 4.0 7.70 8.50 3.54 2.58 2.58 - 2.0 8.70 10.5013 13 10.0 - 2.82 2.82 2.06 - 4.0 7.70 8.50 3.11 3.11 2.49 - 2.0 8.70 10.5016 13 10.0 - 3.22 2.65 1.93 - 4.10 7.80 8.60 3.34 3.03 2.43 - 2.0 8.80 10.6013 13 13.0 - 2.60 2.60 2.60 - 4.10 7.80 8.60 2.93 2.93 2.93 - 2.0 8.80 10.6016 16 10.0 - 3.04 3.04 1.82 - 4.10 7.90 8.70 3.26 2.26 2.37 - 2.0 8.90 10.7016 13 13.0 - 2.99 2.46 2.46 - 4.10 7.90 8.70 3.16 2.87 2.87 - 2.0 8.90 10.7016 16 13.0 - 2.80 2.80 2.30 - 4.20 7.90 8.90 3.06 3.06 2.78 - 2.0 8.90 10.7016 16 16.0 - 2.67 2.67 2.67 - 4.30 8.0 9.0 3.0 3.0 3.0 - 2.0 9.00 10.80

4 units operating 10 10 10.0 10.0 1.98 1.98 1.98 1.98 4.00 7.90 8.70 2.23 2.23 2.23 2.23 2.20 8.90 10.8013 10 10.0 10.0 2.48 1.81 1.81 1.81 4.10 7.90 8.80 2.62 2.09 2.09 2.09 2.20 8.90 10.9016 10 10.0 10.0 2.86 1.71 1.71 1.71 4.10 8.0 9.00 2.83 2.06 2.06 2.06 2.20 9.0 10.9013 13 10.0 10.0 2.31 2.31 1.69 1.69 4.10 8.0 9.00 2.50 2.50 2.0 2.0 2.20 9.0 10.9016 13 10.0 10.0 2.65 2.18 1.59 1.59 4.20 8.0 9.10 2.68 2.43 1.95 1.95 2.20 9.0 11.013 13 13.0 10.0 2.14 2.14 2.14 1.57 4.20 8.0 9.10 2.37 2.37 2.37 1.89 2.20 9.0 11.016 13 13.0 10.0 2.47 2.03 2.03 1.48 4.20 8.0 9.20 2.54 2.31 2.31 1.85 2.20 9.0 11.013 13 13.0 13.0 2.0 2.0 2.0 2.0 4.20 8.0 9.20 2.25 2.25 2.25 2.25 2.20 9.0 11.016 16 10.0 10.0 2.50 2.50 1.50 1.50 4.20 8.0 9.20 2.61 2.61 1.89 1.89 2.20 9.0 11.0

RAS Multi-Split Inverter Combination Ratings

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 12

Page 13: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

13

Combination ratings (size 5M34) heat pump

Operating Status Cooling HeatingCombination Unit capacity (kW) Cooling Capacity (kW) Unit capacity (kW) Heating Capacity (kW)Unit A Unit B Unit C Unit D Unit E Unit A Unit B Unit C Unit D Unit E Min Rated Max Unit A Unit B Unit C Unit D Unit E Min Rated Max

2 units operating 07 07 - - - 2.00 2.00 - - - 2.5 4.0 5.0 2.70 2.70 - - - 1.5 5.4 7.410 07 - - - 2.70 2.00 - - - 2.5 4.7 5.7 4.00 2.70 - - - 1.5 6.7 8.913 07 - - - 3.70 2.00 - - - 2.6 5.7 6.5 4.81 2.59 - - - 1.5 7.4 10.116 07 - - - 4.08 1.82 - - - 2.7 5.9 6.6 5.10 2.50 - - - 1.5 7.6 10.118 07 - - - 4.50 1.80 - - - 2.9 6.3 6.9 5.45 2.45 - - - 1.5 7.9 10.110 10 - - - 2.70 2.70 - - - 2.5 5.4 6.3 3.60 3.60 - - - 1.5 7.2 1013 10 - - - 3.41 2.49 - - - 2.7 5.9 6.6 4.22 3.38 - - - 1.5 7.6 10.116 10 - - - 3.94 2.36 - - - 2.9 6.3 6.9 4.57 3.33 - - - 1.5 7.9 10.118 10 - - - 4.09 2.21 - - - 2.9 6.3 6.9 4.74 3.16 - - - 1.5 7.9 10.113 13 - - - 3.15 3.15 - - - 2.9 6.3 6.9 3.95 3.95 - - - 1.5 7.9 10.116 13 - - - 3.73 3.07 - - - 3.0 6.8 7.2 4.35 3.95 - - - 1.5 8.3 10.218 13 - - - 3.91 2.89 - - - 3.0 6.8 7.2 4.53 3.77 - - - 1.5 8.3 10.216 16 - - - 3.60 3.60 - - - 3.2 7.2 7.5 4.30 4.30 - - - 1.5 8.6 10.218 16 - - - 3.79 3.41 - - - 3.2 7.2 7.5 4.49 4.11 - - - 1.5 8.6 10.218 18 - - - 3.60 3.60 - - - 3.2 7.2 7.5 4.30 4.30 - - - 1.5 8.6 10.2

3 units operating 07 07 07 - - 2.00 2.00 2.00 - - 3.8 6.0 7.5 2.70 2.70 2.70 - - 2 8.1 10.410 07 07 - - 2.70 2.00 2.00 - - 3.8 6.7 8.2 3.53 2.38 2.38 - - 2 8.3 10.413 07 07 - - 3.65 1.97 1.97 - - 3.9 7.6 8.3 4.13 2.23 2.23 - - 2 8.6 10.416 07 07 - - 4.08 1.81 1.81 - - 4.0 7.7 8.5 4.39 2.16 2.16 - - 2 8.7 10.518 07 07 - - 4.28 1.71 1.71 - - 4.0 7.7 8.5 4.58 2.06 2.06 - - 2 8.7 10.510 10 07 - - 2.70 2.70 2.00 - - 3.8 7.4 8.2 3.18 3.18 2.14 - - 2 8.5 10.413 10 07 - - 3.39 2.48 1.83 - - 3.9 7.7 8.3 3.72 2.97 2.01 - - 2 8.7 10.516 10 07 - - 3.77 2.26 1.67 - - 4.0 7.7 8.5 3.92 2.85 1.93 - - 2 8.7 10.518 10 07 - - 3.97 2.14 1.59 - - 4.0 7.7 8.5 4.11 2.74 1.85 - - 2 8.7 10.513 13 07 - - 3.03 3.03 1.64 - - 4.0 7.7 8.5 3.43 3.43 1.85 - - 2 8.7 10.516 13 07 - - 3.44 2.83 1.53 - - 4.1 7.8 8.6 3.67 3.33 1.80 - - 2 8.8 10.618 13 07 - - 3.64 2.70 1.46 - - 4.1 7.8 8.6 3.85 3.21 1.73 - - 2 8.8 10.616 16 07 - - 3.19 3.19 1.42 - - 4.1 7.8 8.6 3.57 3.57 1.75 - - 2 8.9 10.718 16 07 - - 3.39 3.05 1.36 - - 4.1 7.8 8.6 3.76 3.45 1.69 - - 2 8.9 10.718 18 07 - - 3.29 3.29 1.32 - - 4.1 7.9 8.7 3.63 3.63 1.63 - - 2 8.9 10.710 10 10 - - 2.53 2.53 2.53 - - 3.8 7.6 8.2 2.87 2.87 2.87 - - 2 8.6 10.4

13 10 10 - - 3.13 2.28 2.28 - - 3.9 7.7 8.3 3.35 2.68 2.68 - - 2 8.7 10.516 10 10 - - 3.50 2.10 2.10 - - 4.0 7.7 8.5 3.54 2.58 2.58 - - 2 8.7 10.518 10 10 - - 3.70 2.00 2.00 - - 4.0 7.7 8.5 3.73 2.49 2.49 - - 2 8.7 10.513 13 10 - - 2.82 2.82 2.06 - - 4.0 7.7 8.5 3.11 3.11 2.49 - - 2 8.7 10.516 13 10 - - 3.22 2.65 1.93 - - 4.1 7.8 8.6 3.34 3.03 2.43 - - 2 8.8 10.618 13 10 - - 3.42 2.53 1.85 - - 4.1 7.8 8.6 3.52 2.93 2.35 - - 2 8.8 10.616 16 10 - - 3.04 3.04 1.82 - - 4.1 7.9 8.7 3.26 3.26 2.37 - - 2 8.9 10.718 16 10 - - 3.20 2.88 1.73 - - 4.1 7.8 8.6 3.45 3.16 2.30 - - 2 8.9 10.718 18 10 - - 3.11 3.11 1.68 - - 4.1 7.9 8.7 3.34 3.34 2.23 - - 2 8.9 10.713 13 13 - - 2.60 2.60 2.60 - - 4.1 7.8 8.6 2.93 2.93 2.93 - - 2 8.8 10.616 13 13 - - 2.99 2.46 2.46 - - 4.1 7.9 8.7 3.16 2.87 2.87 - - 2 8.9 10.718 13 13 - - 3.19 2.36 2.36 - - 4.1 7.9 8.7 3.34 2.78 2.78 - - 2 8.9 10.716 16 13 - - 2.80 2.80 2.30 - - 4.1 7.9 8.7 3.06 3.06 2.78 - - 2 8.9 10.718 16 13 - - 2.99 2.69 2.21 - - 4.1 7.9 8.7 3.24 2.97 2.70 - - 2 8.9 10.718 18 13 - - 2.88 2.88 2.13 - - 4.1 7.9 8.7 3.14 3.14 2.62 - - 2 8.9 10.7

4 units operating 07 07 07 07 - 1.95 1.95 1.95 1.95 - 4.0 7.8 8.7 2.20 2.20 2.20 2.20 - 2.2 8.8 10.810 07 07 07 - 2.42 1.79 1.79 1.79 - 4.0 7.8 8.7 2.91 1.96 1.96 1.96 - 2.2 8.8 10.813 07 07 07 - 3.01 1.63 1.63 1.63 - 4.1 7.9 8.8 3.36 1.81 1.81 1.81 - 2.2 8.8 10.916 07 07 07 - 3.39 1.50 1.50 1.50 - 4.1 7.9 9.0 3.64 1.79 1.79 1.79 - 2.2 9.0 10.918 07 07 07 - 3.59 1.44 1.44 1.44 - 4.1 7.9 9.0 3.83 1.72 1.72 1.72 - 2.2 9.0 10.910 10 07 07 - 2.24 2.24 1.66 1.66 - 4.0 7.8 8.7 2.63 2.63 1.77 1.77 - 2.2 8.8 10.813 10 07 07 - 2.81 2.05 1.52 1.52 - 4.1 7.9 8.8 3.09 2.47 1.67 1.67 - 2.2 8.9 10.916 10 07 07 - 3.17 1.90 1.41 1.41 - 4.1 7.9 9.0 3.32 2.42 1.63 1.63 - 2.2 9.0 10.918 10 07 07 - 3.38 1.82 1.35 1.35 - 4.1 7.9 9.0 3.51 2.34 1.58 1.58 - 2.2 9.0 10.913 13 07 07 - 2.56 2.56 1.39 1.39 - 4.1 7.9 9.0 2.92 2.92 1.58 1.58 - 2.2 9.0 10.916 13 07 07 - 2.95 2.43 1.31 1.31 - 4.2 8.0 9.1 3.11 2.83 1.53 1.53 - 2.2 9.0 1118 13 07 07 - 3.15 2.33 1.26 1.26 - 4.2 8.0 9.1 3.29 2.74 1.48 1.48 - 2.2 9.0 1116 16 07 07 - 2.77 2.77 1.23 1.23 - 4.2 8.0 9.2 3.02 3.02 1.48 1.48 - 2.2 9.0 1118 16 07 07 - 2.96 2.67 1.19 1.19 - 4.2 8.0 9.2 3.20 2.93 1.44 1.44 - 2.2 9.0 1118 18 07 07 - 2.86 2.86 1.14 1.14 - 4.2 8.0 9.2 3.10 3.10 1.40 1.40 - 2.2 9.0 1110 10 10 07 - 2.11 2.11 2.11 1.56 - 4.0 7.9 8.7 2.39 2.39 2.39 1.62 - 2.2 8.8 10.813 10 10 07 - 2.63 1.92 1.92 1.42 - 4.1 7.9 8.8 2.83 2.27 2.27 1.53 - 2.2 8.9 10.916 10 10 07 - 2.99 1.79 1.79 1.33 - 4.1 7.9 9.0 3.06 2.22 2.22 1.50 - 2.2 9.0 10.918 10 10 07 - 3.23 1.74 1.74 1.29 - 4.1 8.0 9.0 3.23 2.16 2.16 1.46 - 2.2 9.0 10.913 13 10 07 - 2.45 2.45 1.79 1.32 - 4.1 8.0 9.0 2.69 2.69 2.16 1.46 - 2.2 9.0 10.916 13 10 07 - 2.79 2.29 1.67 1.24 - 4.2 8.0 9.1 2.88 2.62 2.09 1.41 - 2.2 9.0 1118 13 10 07 - 2.99 2.21 1.61 1.19 - 4.2 8.0 9.1 3.05 2.54 2.03 1.37 - 2.2 9.0 1116 16 10 07 - 2.63 2.63 1.58 1.17 - 4.2 8.0 9.2 2.80 2.80 2.03 1.37 - 2.2 9.0 1118 16 10 07 - 2.82 2.54 1.52 1.13 - 4.2 8.0 9.2 2.97 2.72 1.98 1.34 - 2.2 9.0 1118 18 10 07 - 2.72 2.72 1.47 1.09 - 4.2 8.0 9.2 2.89 2.89 1.93 1.30 - 2.2 9.0 1113 13 13 07 - 2.26 2.26 2.26 1.22 - 4.2 8.0 9.1 2.54 2.54 2.54 1.37 - 2.2 9.0 1116 13 13 07 - 2.59 2.13 2.13 1.15 - 4.2 8.0 9.2 2.72 2.47 2.47 1.34 - 2.2 9.0 1118 13 13 07 - 2.78 2.06 2.06 1.11 - 4.2 8.0 9.2 2.89 2.41 2.41 1.30 - 2.2 9.0 1116 16 13 07 - 2.45 2.45 2.01 1.09 - 4.2 8.0 9.2 2.65 2.65 2.41 1.30 - 2.2 9.0 1118 16 13 07 - 2.63 2.37 1.95 1.05 - 4.2 8.0 9.2 2.81 2.58 2.34 1.27 - 2.2 9.0 1118 18 13 07 - 2.55 2.55 1.89 1.02 - 4.2 8.0 9.2 2.74 2.74 2.28 1.23 - 2.2 9.0 1110 10 10 10 - 1.98 1.98 1.98 1.98 - 4.0 7.9 8.7 2.23 2.23 2.23 2.23 - 2.2 8.9 10.8

13 10 10 10 - 2.48 1.81 1.81 1.81 - 4.1 7.9 8.8 2.62 2.09 2.09 2.09 - 2.2 8.9 10.916 10 10 10 - 2.86 1.71 1.71 1.71 - 4.1 8.0 9.0 2.83 2.06 2.06 2.06 - 2.2 9.0 10.918 10 10 10 - 3.05 1.65 1.65 1.65 - 4.1 8.0 9.0 3.00 2.00 2.00 2.00 - 2.2 9.0 10.913 13 10 10 - 2.31 2.31 1.69 1.69 - 4.1 8.0 9.0 2.50 2.50 2.00 2.00 - 2.2 9.0 10.916 13 10 10 - 2.65 2.18 1.59 1.59 - 4.2 8.0 9.1 2.68 2.43 1.95 1.95 - 2.2 9.0 1116 16 10 10 - 2.50 2.50 1.50 1.50 - 4.2 8.0 9.2 2.61 2.61 1.89 1.89 - 2.2 9.0 1118 13 10 10 - 2.84 2.10 1.53 1.53 - 4.2 8.0 9.1 2.84 2.37 1.89 1.89 - 2.2 9.0 1118 16 10 10 - 2.68 2.42 1.45 1.45 - 4.2 8.0 9.2 2.77 2.54 1.85 1.85 - 2.2 9.0 1118 18 10 10 - 2.60 2.60 1.40 1.40 - 4.2 8.0 9.2 2.70 2.70 1.80 1.80 - 2.2 9.0 1113 13 13 10 - 2.14 2.14 2.14 1.57 - 4.2 8.0 9.1 2.37 2.37 2.37 1.89 - 2.2 9.0 1116 13 13 10 - 2.47 2.03 2.03 1.48 - 4.2 8.0 9.2 2.54 2.31 2.31 1.85 - 2.2 9.0 1116 16 13 10 - 2.34 2.34 1.92 1.40 - 4.2 8.0 9.2 2.48 2.48 2.25 1.80 - 2.2 9.0 1118 13 13 10 - 2.65 1.96 1.96 1.43 - 4.2 8.0 9.2 2.70 2.25 2.25 1.80 - 2.2 9.0 1118 16 13 10 - 2.52 2.26 1.86 1.36 - 4.2 8.0 9.2 2.63 2.41 2.20 1.76 - 2.2 9.0 1118 18 13 10 - 2.44 2.44 1.80 1.32 - 4.2 8.0 9.2 2.57 2.57 2.14 1.71 - 2.2 9.0 1113 13 13 13 - 2.00 2.00 2.00 2.00 - 4.2 8.0 9.2 2.25 2.25 2.25 2.25 - 2.2 9.0 1116 13 13 13 - 2.31 1.90 1.90 1.90 - 4.2 8.0 9.2 2.41 2.20 2.20 2.20 - 2.2 9.0 1118 13 13 13 - 2.48 1.84 1.84 1.84 - 4.2 8.0 9.2 2.57 2.14 2.14 2.14 - 2.2 9.0 1116 16 13 13 - 2.20 2.20 1.80 1.80 - 4.2 8.0 9.2 2.36 2.36 2.14 2.14 - 2.2 9.0 1118 16 13 13 - 2.37 2.13 1.75 1.75 - 4.2 8.0 9.2 2.51 2.30 2.09 2.09 - 2.2 9.0 1118 18 13 13 - 2.30 2.30 1.70 1.70 - 4.2 8.0 9.2 2.45 2.45 2.05 2.05 - 2.2 9.0 11

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 13

Page 14: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

14

Combination ratings (size 5M34) heat pump

Operating Status Cooling HeatingCombination Unit capacity (kW) Cooling Capacity (kW) Unit capacity (kW) Heating Capacity (kW)Unit A Unit B Unit C Unit D Unit E Unit A Unit B Unit C Unit D Unit E Min Rated Max Unit A Unit B Unit C Unit D Unit E Min Rated Max

5 units operating 07 07 07 07 07 1.96 1.96 1.96 1.96 1.96 3.7 9.8 10.8 2.28 2.28 2.28 2.28 2.28 3.4 11.4 13.410 07 07 07 07 2.50 1.85 1.85 1.85 1.85 3.7 9.9 10.9 3.16 2.13 2.13 2.13 2.13 3.4 11.7 13.713 07 07 07 07 3.13 1.69 1.69 1.69 1.69 3.7 9.9 10.9 3.70 2.00 2.00 2.00 2.00 3.4 11.7 13.716 07 07 07 07 3.56 1.58 1.58 1.58 1.58 3.7 9.9 10.9 3.95 1.94 1.94 1.94 1.94 3.4 11.7 13.718 07 07 07 07 3.81 1.52 1.52 1.52 1.52 3.7 9.9 10.9 4.18 1.88 1.88 1.88 1.88 3.4 11.7 13.710 10 07 07 07 2.34 2.34 1.74 1.74 1.74 3.7 9.9 10.9 2.91 2.91 1.96 1.96 1.96 3.4 11.7 13.713 10 07 07 07 2.95 2.16 1.60 1.60 1.60 3.7 9.9 10.9 3.42 2.74 1.85 1.85 1.85 3.4 11.7 13.716 10 07 07 07 3.38 2.03 1.50 1.50 1.50 3.7 9.9 10.9 3.66 2.66 1.79 1.79 1.79 3.4 11.7 13.718 10 07 07 07 3.61 1.95 1.45 1.45 1.45 3.7 9.9 10.9 3.88 2.59 1.75 1.75 1.75 3.4 11.7 13.713 13 07 07 07 2.73 2.73 1.48 1.48 1.48 3.7 9.9 10.9 3.23 3.23 1.75 1.75 1.75 3.4 11.7 13.716 13 07 07 07 3.14 2.58 1.39 1.39 1.39 3.7 9.9 10.9 3.46 3.15 1.70 1.70 1.70 3.4 11.7 13.718 13 07 07 07 3.37 2.49 1.35 1.35 1.35 3.7 9.9 10.9 3.68 3.06 1.65 1.65 1.65 3.4 11.7 13.716 16 07 07 07 2.97 2.97 1.32 1.32 1.32 3.7 9.9 10.9 3.37 3.37 1.65 1.65 1.65 3.4 11.7 13.718 16 07 07 07 3.19 2.87 1.28 1.28 1.28 3.7 9.9 10.9 3.58 3.28 1.61 1.61 1.61 3.4 11.7 13.710 10 10 07 07 2.21 2.21 2.21 1.64 1.64 3.7 9.9 10.9 2.69 2.69 2.69 1.82 1.82 3.4 11.7 13.713 10 10 07 07 2.80 2.04 2.04 1.51 1.51 3.7 9.9 10.9 3.18 2.54 2.54 1.72 1.72 3.4 11.7 13.713 13 10 07 07 2.60 2.60 1.90 1.40 1.40 3.7 9.9 10.9 3.02 3.02 2.41 1.63 1.63 3.4 11.7 13.716 10 10 07 07 3.21 1.92 1.92 1.42 1.42 3.7 9.9 10.9 3.40 2.48 2.48 1.67 1.67 3.4 11.7 13.718 10 10 07 07 3.44 1.86 1.86 1.38 1.38 3.7 9.9 10.9 3.62 2.41 2.41 1.63 1.63 3.4 11.7 13.713 13 13 07 07 2.43 2.43 2.43 1.31 1.31 3.7 9.9 10.9 2.87 2.87 2.87 1.55 1.55 3.4 11.7 13.716 13 13 07 07 2.80 2.30 2.30 1.25 1.25 3.7 9.9 10.9 3.08 2.80 2.80 1.51 1.51 3.4 11.7 13.718 13 13 07 07 3.02 2.23 2.23 1.21 1.21 3.7 9.9 10.9 3.28 2.73 2.73 1.48 1.48 3.4 11.7 13.716 16 10 07 07 2.84 2.84 1.70 1.26 1.26 3.7 9.9 10.9 3.15 3.15 2.29 1.55 1.55 3.4 11.7 13.718 16 10 07 07 3.06 2.75 1.65 1.22 1.22 3.7 9.9 10.9 3.36 3.08 2.24 1.51 1.51 3.4 11.7 13.718 13 13 07 07 3.02 2.23 2.23 1.21 1.21 3.7 9.9 10.9 3.28 2.73 2.73 1.48 1.48 3.4 11.7 13.716 16 13 07 07 2.67 2.67 2.19 1.19 1.19 3.7 9.9 10.9 3.01 3.01 2.73 1.48 1.48 3.4 11.7 13.718 16 13 07 07 2.88 2.59 2.13 1.15 1.15 3.7 9.9 10.9 3.21 2.94 2.67 1.44 1.44 3.4 11.7 13.710 10 10 10 07 2.09 2.09 2.09 2.09 2.09 3.7 9.9 10.9 2.50 2.50 2.50 2.50 2.50 3.4 11.7 13.713 10 10 10 07 2.65 1.94 1.94 1.94 1.94 3.7 9.9 10.9 2.97 2.38 2.38 2.38 2.38 3.4 11.7 13.716 10 10 10 07 3.05 1.83 1.83 1.83 1.83 3.7 9.9 10.9 3.19 2.32 2.32 2.32 2.32 3.4 11.7 13.7

13 13 10 10 07 2.48 2.48 1.81 1.81 1.81 3.7 9.9 10.9 2.83 2.83 2.26 2.26 2.26 3.4 11.7 13.716 13 10 10 07 2.86 2.35 1.71 1.71 1.71 3.7 9.9 10.9 3.04 2.76 2.21 2.21 2.21 3.4 11.7 13.716 16 10 10 07 2.72 2.72 1.63 1.63 1.63 3.7 9.9 10.9 2.97 2.97 2.16 2.16 2.16 3.4 11.7 13.713 13 13 10 07 2.32 2.32 2.32 1.69 1.69 3.7 9.9 10.9 2.70 2.70 2.70 2.16 2.16 3.4 11.7 13.716 13 13 10 07 2.68 2.21 2.21 1.61 1.61 3.7 9.9 10.9 2.90 2.64 2.64 2.11 2.11 3.4 11.7 13.716 16 13 10 07 2.56 2.56 2.11 1.54 1.54 3.7 9.9 10.9 2.83 2.83 2.58 2.06 2.06 3.4 11.7 13.713 13 13 13 07 2.18 2.18 2.18 2.18 2.18 3.7 9.9 10.9 2.58 2.58 2.58 2.58 2.58 3.4 11.7 13.716 13 13 13 07 2.53 2.08 2.08 2.08 2.08 3.7 9.9 10.9 2.77 2.52 2.52 2.52 2.52 3.4 11.7 13.716 16 13 13 07 2.42 2.42 1.99 1.99 1.99 3.7 9.9 10.9 2.72 2.72 2.47 2.47 2.47 3.4 11.7 13.710 10 10 10 10 1.98 1.98 1.98 1.98 1.98 3.7 9.9 10.9 2.34 2.34 2.34 2.34 2.34 3.4 11.7 13.713 10 10 10 10 2.53 1.84 1.84 1.84 1.84 3.7 9.9 10.9 2.79 2.23 2.23 2.23 2.23 3.4 11.7 13.716 10 10 10 10 2.91 1.75 1.75 1.75 1.75 3.7 9.9 10.9 2.99 2.18 2.18 2.18 2.18 3.4 11.7 13.718 10 10 10 10 3.13 1.69 1.69 1.69 1.69 3.7 9.9 10.9 3.19 2.13 2.13 2.13 2.13 3.4 11.7 13.713 13 10 10 10 2.36 2.36 1.72 1.72 1.72 3.7 9.9 10.9 2.66 2.66 2.13 2.13 2.13 3.4 11.7 13.716 13 10 10 10 2.73 2.25 1.64 1.64 1.64 3.7 9.9 10.9 2.86 2.60 2.08 2.08 2.08 3.4 11.7 13.718 13 10 10 10 2.95 2.18 1.59 1.59 1.59 3.7 9.9 10.9 3.05 2.54 2.03 2.03 2.03 3.4 11.7 13.716 16 10 10 10 2.61 2.61 1.56 1.56 1.56 3.7 9.9 10.9 2.80 2.80 2.03 2.03 2.03 3.4 11.7 13.713 13 13 10 10 2.22 2.22 2.22 1.62 1.62 3.7 9.9 10.9 2.54 2.54 2.54 2.03 2.03 3.4 11.7 13.716 13 13 10 10 2.58 2.12 2.12 1.55 1.55 3.7 9.9 10.9 2.74 2.49 2.49 1.99 1.99 3.4 11.7 13.718 13 13 10 10 2.78 2.06 2.06 1.50 1.50 3.7 9.9 10.9 2.93 2.44 2.44 1.95 1.95 3.4 11.7 13.716 16 13 10 10 2.49 2.49 2.04 1.49 1.49 3.7 10.0 11.0 2.75 2.75 2.50 2.00 2.00 3.4 12.0 1413 13 13 13 10 2.09 2.09 2.09 2.09 2.09 3.7 9.9 10.9 2.44 2.44 2.44 2.44 2.44 3.4 11.7 13.716 13 13 13 10 2.46 2.02 2.02 2.02 2.02 3.7 10.0 11.0 2.69 2.45 2.45 2.45 2.45 3.4 12.0 1418 13 13 13 10 2.66 1.97 1.97 1.97 1.97 3.7 10.0 11.0 2.88 2.40 2.40 2.40 2.40 3.4 12.0 1416 16 13 13 10 2.36 2.36 1.94 1.94 1.94 3.7 10.0 11.0 2.64 2.64 2.40 2.40 2.40 3.4 12.0 1413 13 13 13 13 2.00 2.00 2.00 2.00 2.00 3.7 10.0 11.0 2.40 2.40 2.40 2.40 2.40 3.4 12.0 1416 13 13 13 13 2.33 1.92 1.92 1.92 1.92 3.7 10.0 11.0 2.59 2.35 2.35 2.35 2.35 3.4 12.0 14

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 14

Page 15: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

15

Outdoor unit RAV SM563AT-E SM803AT-E SM1103AT-E SM1403AT-E SM1603AT-EIndoor unit (cassette) RAV SM564UT-E SM804UT-E SM1104UT-E SM1404UT-E SM1604UT-EPanel RBC- U31PG(W)-E U31PG(W)-E U31PG(W)-E U31PG(W)-E U31PG(W)-ERemote control RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E

Cooling capacity range kW 5.3 (1.5-5.6) 6.7 (1.5-7.4) 10.0 (3.0-11.2) 12.1 (3.0-13.2) 14.0 (3.0-16-0) Heating capacity range kW 5.6 (1.5-6.3) 8.0 (1.5-9.0) 11.2 (3.0-13.0) 14.0 (3.0-16.0) 16.0 (3.0-18-0)Power input, cooling/heating kW 1.65/1.44 2.09/2.21 3.11/3.10 3.77/3.88 4.49/4.43EER, cooling/COP heating W/W 3.21/3.89 3.21/3.62 3.22/3.61 3.21/3.61 3.12/3.61Annual power consumption, cooling kWh 825 1045 1555 1885 2245Energy label, cooling/heating A/A A/A A/A A/A B/A

UK conditions - cooling capacity kW 5.44 7.46 10.87 12.61 15.53UK conditions - sensible cooling capacity kW 4.26 5.25 6.67 8.15 11.10UK conditions - heating capacity kW 4.69 6.72 9.68 11.92 13.64

Indoor unit (cassette) RAV SM564UT-E SM804UT-E SM1104UT-E SM1404UT-E SM1604UT-E

Air flow (high/medium/low) l/s 292/242/217 342/267/225 558/400/325 583/400/342 592/417/350Air flow (high/medium/low) m3/h 1050/870/780 1230/960/810 2010/1440/1170 2100/1440/1230 2130/1500/1260

Sound pressure level (high/medium/low)* dB(A) 32/29/28 35/31/28 43/38/33 44/38/34 45/40/36Sound power level (high/medium/low) dB(A) 47/44/43 50/46/43 58/53/48 59/53/49 60/55/51

Dimensions, height x width x depth mm 256 x 840 x 840 256 x 840 x 840 319 x 840 x 840 319 x 840 x 840 319 x 840 x 840Weight kg 20 20 24 24 24Panel dimensions, height x width x depth mm 30 x 950 x 950 30 x 950 x 950 30 x 950 x 950 30 x 950 x 950 30 x 950 x 950Panel weight kg 4.2 4.2 4.2 4.2 4.2

Outdoor unit RAV SM563AT-E SM803AT-E SM1103AT-E SM1403AT-E SM1603AT-E

Air flow l/s (m3/h) 667 (2400) 750 (2700) 1250 (4500) 1250 (4500) 1717 (6180)

Sound pressure level, cooling/heating* dB(A) 46/48 48/50 53/54 53/54 51/53Sound power level, cooling/heating dB(A) 63/65 65/67 70/71 70/71 68/70

Dimensions, height x width x depth mm 550 x 780 x 290 550 x 780 x 290 795 x 900 x 320 795 x 900 x 320 1340 x 900 x 320Weight kg 38 42 77 77 99

Operating range, cooling °C -15 to 43 -15 to 43 -15 to 43 -15 to 43 -15 to 43Operating range, heating °C -15 to 15 -15 to 15 -15 to 15 -15 to 15 -15 to 15

Pipe connections, gas - liquid in 1/2 - 1/4 5/8 - 3/8 5/8 - 3/8 5/8 - 3/8 5/8 - 3/8Pipe length, maximum/minimum m 30/5 30/5 50/5 50/5 50/5Pipe length, pre-charged m 20 20 30 30 30Additional R410A charge g/m 20 40 40 40 40Maximum height difference, above/below m 30/30 30/30 30/30 30/30 30/30

Max. operating current, cooling A 7.9 10.1 14.4 17.7 23.9Suggested fuse size A 10 16 20 20 25Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E 3 + E 3 + E

Retail price

Indoor unit (panel included) £ 760.- 906.- 983.- 1063.- 1074.-Outdoor unit £ 835.- 1215.- 1540.- 1685.- 2110.-System price (remote control included) £ 1647.- 2173.- 2575.- 2800.- 3236.-

Digital Inverter Heat Pump Systems, 4-Way Cassettes

• High EER, low annual power consumption

• High-ceiling temperature sensor control

• Built-in lift pump incorporated

• Infra-red control option

• Turbo fan for improved air throw

• Pentagonal heat exchanger for improved heattransfer

• Louvre and grille are easily detachable andwashable

• Corner pockets permit easy installation andmaintenance

• Twin-split also available

• Ideal for R22 replacementSizes 1103 and 1403 Size 1603

Sizes 563 and 803

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 15

Page 16: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

16

Digital Inverter Heat Pump Systems, Compact 4-Way Cassettes

• Compact 600 x 600 mm cassette

• Easy installation and maintenance via cornerpockets

• Panel depth less than 30 mm for sleek,unobtrusive installation

• TCC Link control panel for flexible, easy systemcontrol

• Control box access is easy, simply remove thesuction grille

• Ideal for R22 replacement

Outdoor unit RAV SM563AT-EIndoor unit (cassette) RAV SM562MUT-EPanel RBC-UM11PG(W)-ERemote control RBC-AMT32E

Cooling capacity range kW 5.0 (1.5-5.6) Heating capacity range kW 5.6 (1.5-6.3)Power input, cooling/heating kW 1.61/1.61EER, cooling/COP heating W/W 3.11/3.48Annual power consumption, cooling kWh 805Energy label, cooling/heating B/B

UK conditions - cooling capacity kW 5.44UK conditions - sensible cooling capacity kW 4.22UK conditions - heating capacity kW 4.69

Indoor unit (cassette) RAV SM562MUT-E

Air flow (low/med/high) l/s 151/186/221Air flow (low/med/high) m3/h 546/672/798

Sound pressure level (low/high)* dB(A) 34/39/43Sound power level (low/high) dB(A) 49/54/58

Dimensions, height x width x depth mm 268 x 575 x 575Weight kg 17Panel dimensions, height x width x depth mm 27 x 700 x 700Panel weight kg 3

Outdoor unit RAV SM563AT-E

Air flow l/s (m3/h) 667 (2400)

Sound pressure level, cooling/heating* dB(A) 46/48Sound power level, cooling/heating dB(A) 63/65

Dimensions, height x width x depth mm 550 x 780 x 290Weight kg 38

Operating range, cooling °C -15 to 43Operating range, heating °C -15 to 15

Pipe connections, gas - liquid in 1/2 - 1/4Pipe length, maximum/minimum m 30/5Pipe length, pre-charged m 20Additional R410A charge g/m 20Maximum height difference, above/below m 30/30

Max. operating current, cooling A 7.9Suggested fuse size A 10Power supply V-ph-Hz 220/240-1-50Supply to Outdoor unitInterconnecting cables 3 + E

Retail price

Indoor unit (panel included) £ 742.-Outdoor unit £ 835.-System price (remote control included) £ 1629.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 16

Page 17: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

17

Outdoor unit RAV SM563AT-E SM803AT-E SM1103AT-E SM1403AT-EIndoor unit (ducted) RAV SM562BT-E SM802BT-E SM1102BT-E SM1402BT-ERemote control RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E

Cooling capacity range kW 5.0 (1.5-5.6) 7.1 (1.5-8.0) 10.0 (3.0-11.2) 12.5 (3.0-13.2) Heating capacity range kW 5.6 (1.5-6.3) 8.0 (1.5-9.0) 11.2 (3.0-12.5) 14.0 (3.0-16.0)Power input, cooling/heating kW 1.78/1.71 2.53/2.41 3.56/3.14 4.42/4.03EER, cooling/COP heating W/W 2.81/3.27 2.81/3.32 2.81/3.57 2.83/3.47Annual power consumption, cooling kWh 890 1265 1780 2210Energy label, cooling/heating C/C C/C C/B C/B

UK conditions - cooling capacity kW 5.44 7.76 10.87 12.81UK conditions - sensible cooling capacity kW 4.20 5.85 7.64 8.73UK conditions - heating capacity kW 4.69 6.70 9.31 11.92

Indoor unit (ducted) RAV SM562BT-E SM802BT-E SM1102BT-E SM1402BT-E

Air flow (low/medium/high) l/s 161/198/217 222/270/317 315/383/450 385/467/550Air flow (low/medium/high) m3/h 581/713/781 799/972/1141 1134/1379/1620 1386/1681/1980

Sound pressure level (low/medium/high)** dB(A) 33/37/40 34/37/40 36/39/42 38/41/44Sound power level (low/medium/high) dB(A) 48/52/55 49/52/55 51/54/57 53/56/59

Dimensions, height x width x depth mm 320 x 700 x 800* 320 x 1000 x 800* 320 x 1350 x 800* 320 x 1350 x 800*Weight kg 30 39 51 51

Discharge spigots mm 2 x 200 3 x 200 4 x 200 4 x 200

Outdoor unit RAV SM563AT-E SM803AT-E SM1103AT-E SM1403AT-E

Air flow l/s (m3/h) 667 (2400) 750 (2700) 1250 (4500) 1250 (4500)

Sound pressure level, cooling/heating* dB(A) 46/48 48/50 53/54 53/54Sound power level, cooling/heating dB(A) 63/65 65/67 70/71 70/71

Dimensions, height x width x depth mm 550 x 780 x 290 550 x 780 x 290 795 x 900 x 320 795 x 900 x 320Weight kg 38 42 77 77

Operating range, cooling °C -15 to 43 -15 to 43 -15 to 43 -15 to 43Operating range, heating °C -15 to 15 -15 to 15 -15 to 15 -15 to 15

Pipe connections, gas - liquid in 1/2 - 1/4 5/8 - 3/8 5/8 - 3/8 5/8 - 3/8Pipe length, maximum/minimum m 30/5 30/5 50/5 50/5Pipe length, pre-charged m 20 20 30 30Additional R410A charge g/m 20 40 40 40Maximum height difference, above/below m 30/30 30/30 30/30 30/30

Max. operating current, cooling A 7.9 10.3 15.0 17.6Suggested fuse size A 10 16 20 20Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E 3 + E

Retail price

Indoor unit £ 585.- 870.- 995.- 1102.-Outdoor unit £ 835.- 1215.- 1540.- 1685.-System price (remote control included) £ 1472.- 2137.- 2587.- 2839.-

• Unobtrusive installation above suspendedceilings for different room layouts and a widerange of applications

• High-performance operation, using digitalinverter control, infra-red control (option)

• High static pressure up to 98 Pa

• Ideal for hotels, banks and similar buildings

• High-lift drain pump kit to 290 mm

• Uniform temperatures throughout the room

• Extremely quiet operation

• Twin-split also available

• Discharge spigots as standard

• Ideal for R22 replacement

Digital Inverter Heat Pump Systems, Ducted Units

Sizes 563 and 803 Sizes 1103 and 1403

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 17

Page 18: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

18

Outdoor unit RAV SM563AT-EIndoor unit (ducted) RAV SM564SDT-ERemote control RBC-AMT32E

Cooling capacity range kW 5.0 (1.5-5.6) Heating capacity range kW 5.6 (1.5-6.3)Power input, cooling/heating kW 1.78/1.71EER, cooling/COP heating W/W 3.01/3.52Annual power consumption, cooling kWh 890Energy label, cooling/heating B/B

UK conditions - cooling capacity kW 5.22UK conditions - sensible cooling capacity kW 3.88UK conditions - heating capacity kW 5.98

Indoor unit (ducted) RAV SM564SDT-E

Air flow (low/medium/high) l/s 162/188/217Air flow (low/medium/high) m3/h 582/678/780

Sound pressure level (low/medium/high)** dB(A) 36/40/45Sound power level (low/medium/high) dB(A) 51/55/60

Dimensions, height x width x depth mm 210 x 845 x 645Weight kg 22

Outdoor unit RAV SM563AT-E

Air flow l/s (m3/h) 667 (2400)

Sound pressure level, cooling/heating* dB(A) 46/48Sound power level, cooling/heating dB(A) 63/65

Dimensions, height x width x depth mm 550 x 780 x 290Weight kg 38

Operating range, cooling °C -15 to 43Operating range, heating °C -15 to 15

Pipe connections, gas - liquid in 1/2 - 1/4Pipe length, maximum/minimum m 30/5Pipe length, pre-charged m 20Additional R410A charge g/m 20Maximum height difference above/below m 30/30

Max. operating current, cooling A 7.9Suggested fuse size A 10Power supply V-ph-Hz 220/240-1-50Supply to Outdoor unitInterconnecting cables 3 + E

Retail price

Indoor unit £ 545.-Outdoor unit £ 835.-System price (including remote control) £ 1432.-

Digital Inverter Heat Pump Systems, Slim Duct Units

• New slim 210 mm deep ducted unit design• Unobtrusive installation above a suspended

ceiling or in a bulkhead for a wide range ofapplications

• High-performance operation, using digitalinverter control

• Static pressures up to 45 Pa• Ideal for hotel and residential applications • Extremely quiet operation• Twin-split also available• Operating range down to -15°C (cooling)

• Ideal for R22 replacement

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 18

Page 19: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

19

Digital Inverter Heat Pump Systems, High-Wall Units

• Attractive, slim-line flat-panel units, ideal foroffices, shops and restaurants

• High-performance operation, using digitalinverter control system

• Enhanced indoor air quality is achieved withToshiba’s five-stage filtration system

• Auto louvre mode ensures even air distributionthroughout the room

• Twin-split and triple-split also available*

• Wireless controller included

• Ideal for R22 replacement

Outdoor unit RAV SM563AT-E SM803AT-EIndoor unit RAV (high-wall unit) SM562KRT-E SM802KRT-ERemote control Infra-red Infra-red

Cooling capacity range kW 5.1 (1.5-5.6) 6.7 (1.5-8.0)Heating capacity range kW 5.6 (1.5-6.3) 8.0 (1.5-9.0)Power input, cooling/heating kW 1.74/1.70 2.72/2.67EER, cooling/COP, heating W/W 2.93/3.29 2.46/3.00Annual power consumption, cooling kWh 870 1360Energy label, cooling/heating C/C E/D

UK conditions - cooling capacity kW 5.44 7.76UK conditions - sensible cooling capacity kW 4.22 5.85UK conditions - heating capacity kW 4.69 6.70

Indoor unit RAV (high-wall unit) SM562KRT-E SM802KRT-E

Air flow (low/medium/high) l/s 178/208/233 203/243/308Air flow (low/medium/high) m3/h 641/749/839 731/875/1109

Sound pressure level (low/medium/high)* dB(A) 33/36/39 36/41/45Sound power level (low/medium/high) dB(A) 48/51/54 51/56/60

Dimensions, height x width x depth mm 298 x 998 x 208 298 x 998 x 208Weight kg 12 12

Outdoor unit RAV SM563AT-E SM803AT-E

Air flow l/s (m3/h) 667 (2400) 750 (2700)

Sound power level, cooling/heating dB(A) 63/65 65/67Sound pressure level, cooling/heating* dB(A) 46/48 48/50

Dimensions, height x width x depth mm 550 x 780 x 290 550 x 780 x 290Weight kg 38 42

Operating range, cooling °C -15 to 43 -15 to 43Operating range, heating °C -15 to 15 -15 to 15

Pipe connections, gas - liquid in 1/2 - 1/4 5/8 - 3/8Pipe length, maximum/minimum m 30/5 30/5Pipe length, pre-charged m 20 20Additional R410A charge g/m 20 40Maximum height difference above/below m 30/30 30/30

Max. operating current, cooling A 7.30 11.32Suggested fuse size A 10 16Power supply V-ph-Hz 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E

* Triple-split only available on 562 units

Retail price

Indoor unit £ 388.- 419.-Outdoor unit £ 835.- 1215.-System price (includes infra-red controller) £ 1223.- 1634.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 19

Page 20: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

20

Outdoor unit RAV SM563AT-E SM803AT-E SM1103AT-E SM1403AT-EIndoor unit (ceiling) RAV SM562CT-E SM802CT-E SM1102CT-E SM1402CT-ERemote control RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E

Cooling capacity range kW 5.0 (1.5-5.6) 7.0 (1.5-8.0) 10.0 (3.0-11.2) 12.3 (3.0-13.2) Heating capacity range kW 5.6 (1.5-6.3) 8.0 (1.5-9.0) 11.2 (3.0-12.5) 14.0 (3.0-16.0)Power input, cooling/heating kW 1.82/1.64 2.53/2.47 3.51/3.20 4.52/4.14EER, cooling/COP, heating W/W 2.75/3.41 2.77/3.24 2.85/3.50 2.72/3.38Annual power consumption, cooling kWh 910 1265 1755 2260Energy label, cooling/heating D/B D/C C/B D/C

UK conditions - cooling capacity kW 5.44 7.76 11.65 13.59UK conditions - sensible cooling capacity kW 4.22 5.85 7.73 8.75UK conditions - heating capacity kW 5.21 7.08 9.68 12.29

Indoor unit (ceiling) RAV SM562CT-E SM802CT-E SM1102CT-E SM1402CT-E

Air flow (low/medium/high) l/s 167/186/217 243/278/308 353/400/458 385/433/500Air flow (low/medium/high) m3/h 601/670/781 875/1001/1109 1271/1440/1649 1386/1559/1800

Sound pressure level (low/medium/high)* dB(A) 30/33/36 33/36/38 35/38/41 37/40/43Sound power level (low/medium/high) dB(A) 45/48/51 48/51/53 50/53/56 52/55/58

Dimensions, height x width x depth mm 210 x 910 x 680 210 x 1180 x 680 210 x 1595 x 680 210 x 1595 x 680Weight kg 21 25 33 33

Outdoor unit RAV SM563AT-E SM803AT-E SM1103AT-E SM1403AT-E

Air flow l/s (m3/h) 667 (2400) 750 (2700) 1250 (4500) 1250 (4500)

Sound pressure level, cooling/heating* dB(A) 46/48 48/50 53/54 53/54Sound power level, cooling/heating dB(A) 63/65 65/67 70/71 70/71

Dimensions, height x width x depth mm 550 x 780 x 290 550 x 780 x 290 795 x 900 x 320 795 x 900 x 320Weight kg 38 42 77 77

Operating range, cooling °C -15 to 43 -15 to 43 -15 to 43 -15 to 43Operating range, heating °C -15 to 15 -15 to 15 -15 to 15 -15 to 15

Pipe connections, gas - liquid in 1/2 - 1/4 5/8 - 3/8 5/8 - 3/8 5/8 - 3/8Pipe length, maximum/minimum m 30/5 30/5 50/5 50/5Pipe length, pre-charged m 20 20 30 30Additional R410A charge g/m 20 40 40 40Maximum height difference, above/below m 30/30 30/30 30/30 30/30

Max. operating current, cooling A 7.9 10.3 15.0 17.6Suggested fuse size A 10 16 20 20Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E 3 + E

Retail price

Indoor unit £ 655.- 775.- 845.- 1105.-Outdoor unit £ 835.- 1215.- 1540.- 1685.-System price (remote control included) £ 1542.- 2042.- 2437.- 2842.-

Digital Inverter Heat Pump Systems, Ceiling Units

• Elegant design with clean lines

• Easy installation and maintenance

• High-performance operation, using digitalinverter control system

• Ideal for offices, classrooms and restaurants

• Automatic louvre control for cooling andheating modes plus auto-swing

• Ultra-quiet operation

• Mould-proof, fully recyclable drain pan

• Twin-split also available

• Ideal for R22 replacement

Sizes 563 and 803 Sizes 1103 and 1403

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 20

Page 21: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

21

• Ultimate flexibility for low-wall or ceiling-suspended installation

• High-performance operation, using digitalinverter control system

• Easy installation and maintenance

• Superior air filtration system for enhancedindoor air quality

• Automatic louvre control for improved airdistribution

• Low noise and recyclable drain pan

• Wireless controller included

• Ideal for R22 replacement

Outdoor unit RAV SM563AT-E SM803AT-EIndoor unit RAV (console/under-ceiling unit)* SM562XT-E SM802XT-ERemote control Infra-red Infra-red

Cooling capacity range kW 5.0 (1.5-5.6) 6.7 (1.5-8.0)Heating capacity range kW 5.6 (1.5-6.3) 8.0 (1.5-9.0)Power input, cooling/heating kW 1.87/1.70 2.72/2.67EER, cooling/COP, heating W/W 2.67/3.29 2.46/3.00Annual power consumption, cooling kWh 935 1360Energy label, cooling/heating D/C E/D

UK conditions - cooling capacity kW 5.44 7.76UK conditions - sensible cooling capacity kW 4.22 5.85UK conditions - heating capacity kW 4.69 6.70

Indoor unit RAV (console/under-ceiling unit)* SM562XT-E SM802XT-E

Air flow (l/m/h) l/s 167/200/233 178/225/308Air flow (l/m/h) m3/h 601/720/839 641/810/1109

Sound pressure level (l/m/h)* dB(A) 36/39/43 37/42/46Sound power level (l/m/h) dB(A) 51/54/58 52/57/61

Dimensions, height x width x depth mm 208 x 1093 x 633 208 x 1093 x 633Weight kg 23 23

Outdoor unit RAV SM563AT-E SM803AT-E

Air flow l/s (m3/h) 667 (2400) 750 (2700)

Sound power level, cooling/heating dB(A) 63/65 65/67Sound pressure level, cooling/heating* dB(A) 46/48 48/50

Dimensions, height x width x depth mm 550 x 780 x 290 550 x 780 x 290Weight kg 38 42

Operating range, cooling °C -15 to 43 -15 to 43Operating range, heating °C -15 to 15 -15 to 15

Pipe connections, gas - liquid in 1/2 - 1/4 5/8 - 3/8Pipe length, maximum/minimum m 30/5 30/5Pipe length, pre-charged m 20 20Additional R410A charge g/m 20 40Maximum height difference above/below m 30/30 30/30

Max. operating current, cooling A 7.30 11.32Suggested fuse size A 10 16Power supply V-ph-Hz 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E

* Cannot be twinned or tripled

Retail price

Indoor unit £ 465.- 485.-Outdoor unit £ 835.- 1215.-System price £ 1300.- 1700.-

Digital Inverter Heat Pump Systems, Console/Under-Ceiling Units

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 21

Page 22: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

22

Digital Inverter Twin-Split Systems

• Allows connection of two indoor units (sametype and capacity) to one outdoor unit

• Indoor units are in the same room, operatesimultaneously and have a single controller

• Twin-operation is possible with all light-commercial indoor units (except XT)

• Precise capacity control at all conditions• Ideal for larger shops and open-plan offices• User-friendly controls• Performance tuning for optimised comfort • Remote control is required (RBC-AMT32-E)*• Ideal for R22 replacement* See accessory page for price

Outdoor unit RAV SM1103AT-E SM1403AT-E SM1603AT-E SM1103AT-E SM1103AT-E SM1403AT-E SM1603AT-EIndoor unit 2 x 4-way cassette 2 x compact 2 x ceiling unit

4-way cassetteRAV SM564UT-E SM804UT-E SM804UT-E SM562MUT-E SM562CT-E SM802CT-E SM802CT-E

Cooling capacity range kW 10.0 (3-11.2) 12.5 (3-13.2) 14.0 (3.0-16.0) 10.0 (3-11.2) 10 (3-11.2) 12.3 (3-13.2) 14.0 (3.0-16.0)Heating capacity range kW 11.2 (3-13) 14 (3-16) 16.0 (3.0-18.0) 11.2 (3-12.5) 11.2 (3-12.5) 14 (3-16) 16.0 (3.0-18.0)Power input, cooling/heating kW 3.52/3.14 4.09/4.0 4.49/4.43 3.51/3.20 3.51/3.20 4.52/4.14 4.99/4.69EER, cooling/COP, heating W/W 3.22/3.62 3.06/3.50 3.12/3.61 2.85/3.50 2.85/3.50 2.72/3.38 2.81/3.41Annual power consumption, cooling kWh 1760 2045 2245 1755 1755 2260 2495Energy label, cooling/heating A/A B/B B/A C/B C/B D/C C/B

UK conditions - cooling capacity kW 10.87 12.81 15.33 10.87 10.87 12.81 15.33UK conditions - sensible cooling capacity kW 6.67 8.35 11.10 6.67 6.67 8.35 11.10UK conditions - heating capacity kW 9.68 11.92 13.64 9.68 9.68 11.92 13.64

Retail price

Retail price, indoor units (2 off) £ 1520.- 1812.- 1812.- 1484.- 1310.- 1550.- 1550.-Retail price, outdoor unit £ 1540.- 1685.- 2110.- 1540.- 1540.- 1685.- 2110.-Retail price, controller (RBC-AMT32E) £ 52.- 52.- 52.- 52.- 52.- 52.- 52.-Total system price £ 3112.- 3549.- 3974.- 3076.- 2902.- 3287.- 3712.-

Outdoor unit RAV SM1103AT-E SM1403AT-E SM1603AT-E SM1103AT-E SM1103AT-E SM1403AT-E SM1603AT-EIndoor unit 2 x ducted unit 2 x slim duct 2 x high-wall unit

RAV SM562BT-E SM802BT-E SM802BT-E SM564SDT-E SM562KRT-E SM802KRT-E SM802KRT-E

Cooling capacity range kW 10 (3-11.2) 12.5 (3-13.2) 14.0 (3.0-15.0) 10 (3-11.2) 10 (3-11.2) 12.0 (3-13) 14.0 (3.0-16.0)Heating capacity range kW 11.2 (3-12.5) 14 (3-16) 16.0 (3.0-18.0) 11.2 (3-12.5) 11.2 (3-12.5) 14 (3-16) 16.0 (3.0-18.0)Power input, cooling/heating kW 3.56/3.14 4.42/4.03 5.12/4.69 3.48/3.14 3.48/3.14 4.52/4.24 5.10/4.98EER, cooling/COP, heating W/W 2.81/3.57 2.83/3.47 2.73/3.41 2.87/3.57 2.87/3.57 2.65/3.30 2.75/3.21Annual power consumption, cooling kWh 1780 2210 2560 1740 1740 2260 2550Energy label, cooling/heating C/B C/B D/B B/B C/B D/C D/B

UK conditions - cooling capacity kW 10.87 12.81 15.33 10.87 10.87 12.81 15.33UK conditions - sensible cooling capacity kW 6.67 8.35 11.10 6.67 6.67 8.35 11.10UK conditions - heating capacity kW 9.68 11.92 13.64 9.68 9.68 11.92 13.64

Retail price

Retail price, indoor units (2 off) £ 1170.- 1740.- 1740.- 1090.- 776.- 838.- 838.-Retail price, outdoor unit £ 1540.- 1685.- 2110.- 1540.- 1540.- 1685.- 2110.-Retail price, controller (RBC-AMT32E) £ 52.- 52.- 52.- 52.- 52.- 52.- 52.-Total system price £ 2762.- 3477.- 3902.- 2682.- 2368.- 2575.- 3000.-

Outdoor unit RAV SM1103AT-E SM1403AT-E SM1603AT-E

Air flow l/s (m3/h) 1250 (4500) 1250 (4500) 1717 (6180)

Sound pressure level, cooling/heating* dB(A) 53/54 53/54 51/53Sound power level, cooling/heating dB(A) 70/71 70/71 68/70

Dimensions, height x width x depth mm 795 x 900 x 320 795 x 900 x 320 1340 x 900 x 320Weight kg 77 77 99

Operating range, cooling/heating °C -15 to 43/-15 to 15 -15 to 43/-15 to 15 -15 to 43/-15 to 15

Pipe connections, gas - liquid in 5/8 - 3/8 5/8 - 3/8 5/8 - 3/8Pipe length, maximum/pre-charged m 50/30 50/30 50/30Additional R410A charge g/m 40 40 40Maximum height difference, above/below m 30/30 30/30 30/30

Max. operating current, cooling A 15.0 17.6 23.9Suggested fuse size A 20 20 25Power supply (to outdoor unit) V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50Interconnecting cables 3 + E 3 + E 3 + E

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 22

Page 23: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

23

Digital Inverter Triple-Split Systems

• Allows connection of three indoor units (sametype and capacity) to one outdoor unit

• Indoor units are in the same room, operatesimultaneously and have a single controller

• Triple-operation is possible with all light-commercial indoor units (except XT)

• Precise capacity control at all conditions• Ideal for larger shops and open-plan offices• User-friendly controls• Performance tuning for optimised comfort • Requires a triple connection kit (TRP100)*• Remote control is required (RBC-AMT32-E)*• Ideal for R22 replacement* See accessory page for price

Outdoor unit RAV SM1603AT-E SM1603AT-E SM1603AT-EIndoor unit 3 x 4-way cassette 3 x compact 4-way cassette 3 x ceiling unit

RAV SM564UT-E SM562MUT-E SM562CT-E

Cooling capacity range kW 14.0 (3.0-16.0) 14.0 (3.0-16.0) 14.0 (3.0-16.0)Heating capacity range kW 16.0 (3.0-18.0) 16.0 (3.0-18.0) 16.0 (3.0-18.0)Power input, cooling/heating kW 4.49/4.43 4.99/4.69 4.99/4.69EER, cooling/COP, heating W/W 3.12/3.61 2.81/3.41 2.81/3.41Annual power consumption, cooling kWh 2245 2495 2495Energy label, cooling/heating B/A C/B C/B

UK conditions - cooling capacity kW 15.33 15.33 15.33UK conditions - sensible cooling capacity kW 11.10 11.10 11.10UK conditions - heating capacity kW 13.64 13.64 13.64

Retail price

Retail price, indoor units (3 off) £ 2280.- 2226.- 1965.-Retail price, outdoor unit £ 2110.- 2110.- 2110.-Retail price, triple kit (RBC-TRP100E) £ 159.- 159.- 159.-Retail price, controller (RBC-AMT32E) £ 52.- 52.- 52.-Total system price £ 4601.- 4547.- 4286.-

Outdoor unit RAV SM1603AT-E SM1603AT-E SM1603AT-EIndoor unit 3 x Ducted 3 x slim duct 3 x high-wall

RAV SM562BT-E SM564SDT-E SM562KRT-E

Cooling capacity range kW 14.0 (3.0-16.0) 14.0 (3.0-16.0) 14.0 (3.0-16.0)Heating capacity range kW 16.0 (3.0-18.0) 16.0 (3.0-18.0) 16.0 (3.0-18.0)Power input, cooling/heating kW 5.12/4.69 4.99/4.69 5.10/4.98EER, cooling/COP, heating W/W 2.73/3.41 2.81/3.41 2.75/3.21Annual power consumption, cooling kWh 2560 2495 2550Energy label, cooling/heating D/B C/B D/C

UK conditions - cooling capacity kW 15.33 15.33 15.33UK conditions - sensible cooling capacity kW 11.10 11.10 11.10UK conditions - heating capacity kW 13.64 13.64 13.64

Retail price

Retail price, indoor units (3 off) £ 1755.- 1635.- 1164.-Retail price, outdoor unit £ 2110.- 2110.- 2110.-Retail price, triple kit (TRP100)) £ 159.- 159.- 159.-Retail price, controller (RBC-AMT32E) £ 52.- 52.- 52.-Total system price £ 4076.- 3956.- 3485.-

Outdoor unit RAV SM1603AT-E

Air flow l/s (m3/h) 1717 (6180)

Sound pressure level, cooling/heating* dB(A) 51/53Sound power level, cooling/heating dB(A) 68/70

Dimensions, height x width x depth mm 1340 x 900 x 320Weight kg 99

Operating range, cooling/heating °C -15 to 43/-15 to 15

Pipe connections, gas - liquid in 5/8 - 3/8Pipe length, maximum/pre-charged m 50/30Additional R410A charge g/m 40Maximum height difference, above/below m 30/30

Max. operating current, cooling A 23.9Suggested fuse size A 25Power supply (to outdoor unit) V-ph-Hz 220/240-1-50Interconnecting cables 3 + E

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 23

Page 24: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

24

Large Capacity Digital Inverter

• Allows connection of two, three or four indoor

units of the same type

• Indoor units are in the same room, operate

together and have a single remote controller

(ALL in the same MODE)

• Outdoor unit 400V, 3 phase supply

• High efficiency twin rotary inverter compressor

• Light weight, easy to install and space saving

footprint

• Requires a twin, double-twin or tripleconnection kit (RBC-TWP101E, RBC-DTWP101E or RBC-TRP100E).

• Ideal for R22 replacement

Combination Table

RAV-SM2244AT series Branch kit

RBC-TWP101E

RBC-TRP100E

RBC-DTWP101E

Twin(Simultaneous Same Mode Operation)

Triple(Simultaneous Same Mode Operation)

Double Twin(Simultaneous Same Mode Operation)

SM110 SM110

SM80 SM80

SM56 SM56

SM80

SM56 SM56

RAV-SM2804AT series Branch kit

RBC-TWP101E

RBC-TRP100E

RBC-DTWP101E

Twin(Simultaneous Same Mode Operation)

Triple(Simultaneous Same Mode Operation)

Double Twin(Simultaneous Same Mode Operation)

SM140 SM140

SM80 SM80

SM80 SM80

SM80

SM80 SM80

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 24

Page 25: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

25

Outdoor Unit Large Capacity Digital Inverter RAV SM2244AT8-E SM2804AT8-E SM2244AT8-E SM2804AT8-EIndoor Unit 2 x 4 Way Cassette 2 x Ducted

RAV SM1104UT-E SM1404UT-E SM1102BT-E SM1402BT-E

Cooling capacity range kW 20 (9.8-22.4) 23 (9.8-27) 20 (9.8-22.4) 23 (9.8-27)Heating capacity range kW 22.4 (9.8-25.0) 28 (9.8-31.5) 22.4 (9.8-25.0) 28 (9.8-31.5)Power Input, cooling / heating kW 6.24 / 5.82 8.19 / 7.48 7.12 / 6.40 9.55 / 7.92EER, cooling / COP heating W/W 3.21 / 3.85 2.81 / 3.61 2.81 / 3.50 2.41 / 3.41Energy Label, cooling / heating A / A C / A C / B E / B

UK Conditions Cooling ** kW 21.7 26.2 21.7 26.2UK Conditions Sensible Cooling ** kW 14.9 17.7 14.9 17.7UK Conditions Heating ** kW 14.0 17.4 14.0 17.4

Retail Price Indoor Units (2 off) £ 1966 2126 1990 2204Retail Price Outdoor Unit £ 3000 3150 3000 3150Retail Price Twin Kit (TWP101E) £ 133 133 133 133Retail Price Controller (RBC-AMT32E) £ 52 52 52 52

Retail price

Total System Price £ 5151.- 5461.- 5175.- 5539.-

Outdoor Unit Large Capacity Digital Inverter RAV SM2244AT8-E SM2804AT8-EIndoor Unit 2 x Ceiling

RAV SM1102CT-E SM1402CT-E

Cooling capacity range kW 20 (9.8-22.4) 23 (9.8-27)Heating capacity range kW 22.4 (9.8-25.0) 28 (9.8-31.5)Power Input, cooling / heating kW 7.12 / 6.40 9.55 / 7.92EER, cooling / COP heating W/W 2.81 / 3.50 2.41 / 3.41Energy Label, cooling / heating C / B E / B

UK Conditions Cooling ** kW 21.7 26.2UK Conditions Sensible Cooling ** kW 14.9 17.7UK Conditions Heating ** kW 14.0 17.4

Retail Price Indoor Units (2 off) £ 1690 2210Retail Price Outdoor Unit £ 3000 3150Retail Price Twin Kit (TWP101E) £ 133 133Retail Price Controller (RBC-AMT32E) £ 52 52

Retail price

Total System Price £ 4875.- 5545.-

Outdoor Unit Details RAV SM2244AT8-E SM2804AT8-E

Air Flow m³/min 133 133

Sound Presure Level, Cooling / Heating db(A) 56 / 57 57 / 58Sound Power Level, Cooling / Heating db(A) 72 / 74 74 / 75

Dimensions, height, width, depth H x W x D 1540 x 900 x 320 1540 x 900 x 320Weight kg 133 133

Operation Range. Cooling / heating °C -15 to 46 / -20 to 15 -15 to 46 / -20 to 15

Pipe Connections, gas - liquid in 1 1/8" - 1.2" 1 1/8" - 1.2"Pipe Length Maximum/pre-charged m 70 / 30 70 / 30Additional R410a charge g/m Refer to Manual Refer to ManualMaximum height difference, above/below m 30 / 30 30 / 30Max operating Current, cooling A 18 22Sugested Fuse Size A 25 25Power supply to outdoor unit V-ph-HZ 400 - 3 - 50 400 - 3 - 50Interconnecting cables 3 + E 3 + E

Note ** - UK Conditions are calculated and are approximations only

Large Capacity Digital Inverter, Twin Splits

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 25

Page 26: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

26

Outdoor Unit Large Capacity Digital Inverter RAV SM2244AT8-E SM2804AT8-E SM2244AT8-E SM2804AT8-EIndoor Unit 3 x 4 Way Cassette 3 x Ducted

RAV SM804UT-E SM804UT-E SM802BT-E SM802BT-E

Cooling capacity range kW 20 (9.8-22.4) 23 (9.8-27) 20 (9.8-22.4) 23 (9.8-27)Heating capacity range kW 22.4 (9.8-25.0) 28 (9.8-31.5) 22.4 (9.8-25.0) 28 (9.8-31.5)Power Input, cooling / heating kW 7.12 / 6.40 9.55 / 7.92 7.12 / 6.40 9.55 / 7.92EER, cooling / COP heating W/W 3.21 / 3.85 2.41 / 3.41 2.81 / 3.50 2.41 / 3.41Energy Label, cooling / heating A / A E / B C / B E / B

UK Conditions Cooling ** kW 21.7 26.2 21.7 26.2UK Conditions Sensible Cooling ** kW 16.7 20.9 14.9 17.7UK Conditions Heating ** kW 15.9 19.7 14.0 17.4

Retail Price Indoor Units (3 off) £ 2718 2718 2610 2610Retail Price Outdoor Unit £ 3000 3150 3000 3150Retail Price Triple Kit (TRP100E) £ 159 159 159 159Retail Price Controller (RBC-AMT32E) £ 52 52 52 52

Retail price

Total System Price £ 5929.- 6079.- 5821.- 5971.-

Outdoor Unit Large Capacity Digital Inverter RAV SM2244AT8-E SM2804AT8-E SM2244AT8-E SM2804AT8-EIndoor Unit 3 x Ceiling 3 x Hi Wall

RAV SM802CT-E SM802CT-E SM802KRT-E SM802KRT-E

Cooling capacity range kW 20 (9.8-22.4) 23 (9.8-27) 20 (9.8-22.4) 23 (9.8-27)Heating capacity range kW 22.4 (9.8-25.0) 28 (9.8-31.5) 22.4 (9.8-25.0) 28 (9.8-31.5)Power Input, cooling / heating kW 7.12 / 6.40 9.55 / 7.92 7.12 / 6.40 9.55 / 7.92EER, cooling / COP heating W/W 2.81 / 3.50 2.41 / 3.41 2.81 / 3.50 2.41 / 3.41Energy Label, cooling / heating C / B E / B C / B E / B

UK Conditions Cooling ** kW 21.7 26.2 21.7 26.2UK Conditions Sensible Cooling ** kW 14.9 17.7 14.9 17.7UK Conditions Heating ** kW 14.0 17.4 14.0 17.4

Retail Price Indoor Units (3 off) £ 2325 2325 1257 1257Retail Price Outdoor Unit £ 3000 3150 3000 3150Retail Price Triple Kit (TRP100E) £ 159 159 159 159Retail Price Controller (RBC-AMT32E) £ 52 52 52 52

Retail price

Total System Price £ 5536.- 5686.- 4468.- 4618

Outdoor Unit Details RAV SM2244AT8-E SM2804AT8-E

Air Flow m³/min 133 133

Sound Presure Level, Cooling / Heating db(A) 56 / 57 57 / 58Sound Power Level, Cooling / Heating db(A) 72 / 74 74 / 75

Dimensions, height, width, depth H x W x D 1540 x 900 x 320 1540 x 900 x 320Weight kg 133 133

Operation Range. Cooling / heating °C -15 to 46 / -20 to 15 -15 to 46 / -20 to 15

Pipe Connections, gas - liquid in 1 1/8" - 1.2" 1 1/8" - 1.2"Pipe Length Maximum/pre-charged m 70 / 30 70 / 30Additional R410a charge g/m Refer to Manual Refer to ManualMaximum height difference, above/below m 30 / 30 30 / 30Max operating Current, cooling A 18 22Sugested Fuse Size A 25 25Power supply to outdoor unit V-ph-HZ 400 - 3 - 50 400 - 3 - 50Interconnecting cables 3 + E 3 + E

Note ** - UK Conditions are calculated and are approximations only

Large Capacity Digital Inverter, Triple Splits

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 26

Page 27: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

27

OOutdoor Unit Large Capacity Digital Inverter RAV SM2244AT8-E SM2804AT8-E SM2244AT8-E SM2244AT8-E SM2804AT8-EIndoor Unit 4 x 4 Way Cassette 4 x Compact 4 Way Cassette 4 x Ceiling

RAV SM564UT-E SM804UT-E SM562MUT-E SM562CT-E SM802CT-E

Cooling capacity range kW 20 (9.8-22.4) 23 (9.8-27) 20 (9.8-22.4) 20 (9.8-22.4) 23 (9.8-27)Heating capacity range kW 22.4 (9.8-25.0) 28 (9.8-31.5) 22.4 (9.8-25.0) 22.4 (9.8-25.0) 28 (9.8-31.5)Power Input, cooling / heating kW 7.12 / 6.40 9.55 / 7.92 7.12 / 6.40 7.12 / 6.40 9.55 / 7.92EER, cooling / COP heating W/W 3.21 / 3.85 2.41 / 3.41 2.81 / 3.50 2.81 / 3.50 2.41 / 3.41Energy Label, cooling / heating A / A E / B C / B C / B E / B

UK Conditions Cooling ** kW 21.7 26.2 21.7 21.7 26.2UK Conditions Sensible Cooling ** kW 16.7 20.9 14.9 14.9 17.7UK Conditions Heating ** kW 15.9 19.7 14.0 14.0 17.4

Retail Price Indoor Units (4 off) £ 3040 3624 2968 2620 3100Retail Price Outdoor Unit £ 3000 3150 3000 3000 3150Retail Price Double Twin Kit (1 xDTWP100E) £ 181 181 181 181 181Retail Price Controller (RBC-AMT32E) £ 52 52 52 52 52

Retail price

Total System Price £ 6273.- 7007.- 6201.- 5853.- 6483.-

Outdoor Unit Large Capacity Digital Inverter RAV SM2244AT8-E SM2804AT8-E SM2244AT8-E SM2244AT8-E SM2804AT8-EIndoor Unit 4 x Ducted 4 x Slim Ducted 4 x Hi Wall

RAV SM562BT-E SM802BT-E SM564SDT-E SM562KRT-E SM802KRT-E

Cooling capacity range kW 20 (9.8-22.4) 23 (9.8-27) 20 (9.8-22.4) 20 (9.8-22.4) 23 (9.8-27)Heating capacity range kW 22.4 (9.8-25.0) 28 (9.8-31.5) 22.4 (9.8-25.0) 22.4 (9.8-25.0) 28 (9.8-31.5)Power Input, cooling / heating kW 7.12 / 6.40 9.55 / 7.92 7.12 / 6.40 7.12 / 6.40 9.55 / 7.92EER, cooling / COP heating W/W 2.81 / 3.50 2.41 / 3.41 2.81 / 3.50 2.81 / 3.50 2.41 / 3.41Energy Label, cooling / heating C / B E / B C / B C / B E / B

UK Conditions Cooling ** kW 21.7 26.2 21.7 21.7 26.2UK Conditions Sensible Cooling ** kW 14.9 17.7 14.9 14.9 17.7UK Conditions Heating ** kW 14.0 17.4 14.0 14.0 17.4

Retail Price Indoor Units (4 off) £ 2340 3480 2180 1552 1676Retail Price Outdoor Unit £ 3000 3150 3000 3000 3150Retail Price Double Twin Kit (1 xDTWP100E) £ 181 181 181 181 181Retail Price Controller (RBC-AMT32E) £ 52 52 52 52 52

Retail price

Total System Price £ 5573.- 6863.- 5413.- 4785.- 5059.-

Outdoor Unit Details RAV SM2244AT8-E SM2804AT8-E

Air Flow m³/min 133 133

Sound Presure Level, Cooling / Heating db(A) 56 / 57 57 / 58Sound Power Level, Cooling / Heating db(A) 72 / 74 74 / 75

Dimensions, height, width, depth H x W x D 1540 x 900 x 320 1540 x 900 x 320Weight kg 133 133

Operation Range. Cooling / heating °C -15 to 46 / -20 to 15 -15 to 46 / -20 to 15

Pipe Connections, gas - liquid in 1 1/8" - 1.2" 1 1/8" - 1.2"Pipe Length Maximum/pre-charged m 70 / 30 70 / 30Additional R410a charge g/m Refer to Manual Refer to ManualMaximum height difference, above/below m 30 / 30 30 / 30Max operating Current, cooling A 18 22Sugested Fuse Size A 25 25Power supply to outdoor unit V-ph-HZ 400 - 3 - 50 400 - 3 - 50Interconnecting cables 3 + E 3 + E

Note ** - UK Conditions are calculated and are approximations only

Large Capacity Digital Inverter, Double Twin Splits

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:01 Page 27

Page 28: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

28

Super Digital Inverter Heat Pump Systems, 4-Way Cassettes

Outdoor unit RAV SP564AT-E SP804AT-E SP1104AT-E SP1404AT-EIndoor unit (cassette) RAV SM564UT-E SM804UT-E SM1104UT-E SM1404UT-EPanel RBC-U31PG(W)-E RBC-U31PG(W)-E RBC-U31PG(W)-E RBC-U31PG(W)-ERemote control RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E

Cooling capacity range kW 5.3 (1.2-5.6) 7.1 (1.9-8.0) 10.0 (2.6-12.0) 12.3 (2.6-14.0) Heating capacity range kW 5.6 (0.9-8.1) 8.0 (1.3-11.3) 11.2 (2.4-13.0) 14.0 (2.4-16.5)Power input, cooling/heating kW 1.49/1.91 1.86/1.91 2.21/2.34 3.16/3.21EER, cooling/COP heating W/W 3.61/4.63 3.82/4.19 4.52/4.79 3.96/4.36Annual power consumption, cooling kWh 735 930 1105 1580Energy label, cooling/heating A/A A/A A/A A/A

UK conditions - cooling capacity kW 5.44 7.46 10.87 12.61UK conditions - sensible cooling capacity kW 4.26 5.25 6.67 8.15UK conditions - heating capacity kW 4.69 6.72 9.68 11.92

Indoor unit (cassette) RAV SM564UT-E SM804UT-E SM1104UT-E SM1404UT-E

Air flow (high/medium/low) l/s 292/242/217 342/267/225 558/400/325 583/400/342Air flow (high/medium/low) m3/h 1050/870/780 1230/960/810 2010/1440/1170 2100/1440/1230

Sound pressure level (high/medium/low)* dB(A) 32/29/27 37/31/28 39/36/33 47/38/34Sound power level (high/medium/low) dB(A) 47/44/42 52/46/43 54/51/46 62/53/49

Dimensions, height x width x depth mm 256 x 840 x 840 256 x 840 x 840 319 x 840 x 840 319 x 840 x 840Weight kg 21 22 26 26Panel dimensions, height x width x depth mm 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950 35 x 950 x 950Panel weight kg 4.5 4.5 4.5 4.5

Outdoor unit RAV SP564AT-E SP804AT-E SP1104AT-E SP1404AT-E

Air flow l/s (m3/h) 667 (2400) 833 (3000) 1683 (6060) 1716 (6180)

Sound pressure level, cooling/heating* dB(A) 47/48 48/49 49/50 51/52Sound power level, cooling/heating dB(A) 64/65 65/66 66/67 68/69

Dimensions, height x width x depth mm 550 x 780 x 290 890 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320Weight kg 44 63 93 93

Operating range, cooling °C -15 to 43 -15 to 43 -15 to 43 -15 to 43Operating range, heating °C -20 to 15 -20 to 15 -15 to 15 -15 to 15

Pipe connections, gas - liquid in 1/2 - 1/4 5/8 - 3/8 5/8 - 3/8 5/8 - 3/8Pipe length, maximum/minimum m 50/5 50/5 75/5 75/5Pipe length, pre-charged m 20 30 30 30Additional R410A charge g/m 20 40 40 40Maximum height difference m 30 30 30 30

Max. operating current, cooling A 6.82 8.72 11.24 16.21Suggested fuse size A 10 10 20 20Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E 3 + E

Retail price

Indoor unit £ 760.- 906.- 983.- 1063.-Outdoor unit £ 1015.- 1510.- 1900.- 2100.-System price £ 1827.- 2468.- 2935.- 3215.-

Digital Inverter features, plus:• Increased energy efficiency/cost savings• New fan motor and enhanced compressor

design• Extended pipe runs/greater flexibility• More steps for precise inverter control• Improved sound levels and operating range

down to -15°C (cooling) • EER values up to 4.17 in cooling mode• All of the units have energy label A• High-performance heating, even at -15°C• Increased heat exchanger efficiency• High-ceiling teperature sensor

• Turbo fan improves air throw whilst the heatexchanger improves heat transfer

• Ideal for R22 replacement

Size 564 Size 804 Sizes 1104 and 1404

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 28

Page 29: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

29

Super Digital Inverter Heat Pump Systems, Compact 4-Way Cassettes

• Compact 600 x 600 mm cassette

• Single and twin-split option

• New louvre design

• Easy control access via corner pockets

• Panel height 17 mm for sleek, unobtrusiveinstallation

• TCC Link control panel for flexible, easy systemcontrol

• All rated A for energy efficiency

• Connection kit required for twin system; thisincludes a noise suppressor and pipe joint

• Ideal for R22 replacement

Outdoor unit RAV SP404AT-E SP564AT-EIndoor unit (cassette) RAV SM402MUT-E SM562MUT-EPanel RBC-UM11PG(W)-E RBC-UM11PG(W)-ERemote control RBC-AMT32E RBC-AMT32E

Cooling capacity range kW 3.6 (1.5-4.0) 5.0 (1.2-5.6) Heating capacity range kW 4.0 (1.5-5.0) 5.6 (0.9-7.4)Power input, cooling/heating kW 1.00/0.97 1.19/1.54EER, cooling/COP heating W/W 3.60/4.12 3.11/3.62Annual power consumption, cooling kWh 500 780Energy label, cooling/heating A/A B/A

UK conditions - cooling capacity kW 3.88 5.44UK conditions - sensible cooling capacity kW 3.20 4.22UK conditions - heating capacity kW 4.93 4.69

Indoor unit (cassette) RAV SM402MUT-E SM562MUT-E

Air flow (low/medium/high) l/s 130/153/183 151/186/221Air flow (low/medium/high) m3/h 468/552/660 546/672/798

Sound pressure level (low/medium/high)* dB(A) 31/36/40 34/39/43Sound power level (low/medium/high) dB(A) 46/51/55 49/54/58

Dimensions, height x width x depth mm 268 x 575 x 575 268 x 575 x 575Weight kg 17 17Panel dimensions, height x width x depth mm 27 x 700 x 700 27 x 700 x 700Panel weight kg 3 3

Outdoor unit RAV SP404AT-E SP564AT-E

Air flow l/s (m3/h) 667 (2400) 667 (2400)

Sound pressure level, cooling/heating* dB(A) 45/47 47/48Sound power level, cooling/heating dB(A) 62/64 64/65

Dimensions, height x width x depth mm 550 x 780 x 290 550 x 780 x 290Weight kg 40 44

Operating range, cooling °C -15 to 43 -15 to 43Operating range, heating °C -15 to 15 -20 to 15

Pipe connections, gas - liquid in 1/2 - 1/4 1/2 - 1/4Pipe length, maximum/minimum m 30/5 50/5Pipe length, pre-charged m 20 20Additional R410A charge g/m 20 20Maximum height difference, above/below m 30/30 30/30

Max. operating current, cooling A 5.2 7.24Suggested fuse size A 10 10Power supply V-ph-Hz 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E

Retail price

Indoor unit (panel included) £ 717.- 742.-Outdoor unit £ 950.- 1015.-System price (remote control included) £ 1719.- 1809.-

Sizes 404 and 564

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 29

Page 30: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

30

Outdoor unit RAV SP564AT-E SP804AT-E SP1104AT-E SP1404AT-EIndoor unit (ducted) RAV SM562BT-E SM802BT-E SM1102BT-E SM1402BT-ERemote control RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E

Cooling capacity range kW 5.0 (1.2-5.6) 7.1 (1.9-8.0) 10.0 (2.6-12.0) 12.5 (2.6-14.0) Heating capacity range kW 5.6 (0.9-7.4) 8.0 (1.3-10.6) 11.2 (2.4-13.0) 14.0 (2.4-16.5)Power input, cooling/heating kW 1.39/1.55 2.21/2.21 2.94/2.77 3.83/3.41EER, cooling/COP heating W/W 3.03/3.51 2.98/3.57 3.40/4.04 3.26/4.11Annual power consumption, cooling kWh 780 1105 1470 1915Energy label, cooling/heating B/B C/B A/A A/A

UK conditions - cooling capacity kW 5.44 7.76 11.65 13.59UK conditions - sensible cooling capacity kW 4.20 5.85 8.19 9.26UK conditions - heating capacity kW 5.21 7.08 9.68 12.29

Indoor unit (ducted) RAV SM562BT-E SM802BT-E SM1102BT-E SM1402BT-E

Air flow (low/medium/high) l/s 161/198/217 222/270/317 315/383/450 385/467/550Air flow (low/medium/high) m3/h 581/713/781 799/972/1141 1134/1379/1620 1386/1681/1980

Sound pressure level (low/medium/high)** dB(A) 33/37/40 34/37/40 36/39/42 38/41/44Sound power level (low/medium/high) dB(A) 48/52/55 49/52/55 51/54/57 53/56/59

Dimensions, height x width x depth mm 320 x 700 x 800* 320 x 1000 x 800* 320 x 1350 x 800* 320 x 1350 x 800*Weight kg 30 39 54 54

Discharge spigots mm 2 x 200 3 x 200 4 x 200 4 x 200

* The height of the flange is 75 mm

Outdoor unit RAV SP564AT-E SP804AT-E SP1104AT-E SP1404AT-E

Air flow l/s (m3/h) 667 (2400) 833 (3000) 1683 (6060) 1716 (6180)

Sound pressure level, cooling/heating* dB(A) 47/48 48/49 49/50 51/52Sound power level, cooling/heating dB(A) 64/65 65/66 66/67 68/69

Dimensions, height x width x depth mm 550 x 780 x 290 890 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320Weight kg 44 63 93 93

Operating range, cooling °C -15 to 43 -15 to 43 -15 to 43 -15 to 43Operating range, heating °C -20 to 15 -20 to 15 -15 to 15 -15 to 15

Pipe connections, gas - liquid in 1/2 - 1/4 5/8 - 3/8 5/8 - 3/8 5/8 - 3/8Pipe length, maximum/minimum m 50/5 50/5 75/5 75/5Pipe length, pre-charged m 20 30 30 30Additional R410A charge g/m 20 40 40 40Maximum height difference m 30 30 30 30

Max. operating current, cooling A 7.24 10.36 11.24 16.21Suggested fuse size A 10 10 20 20Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E 3 + E

Retail price

Indoor unit £ 585.- 870.- 995.- 1102.-Outdoor unit £ 1015.- 1510.- 1900.- 2100.-System price £ 1652.- 2432.- 2947.- 3254.-

Super Digital Inverter Heat Pump Systems, Ducted Units

Digital Inverter features, plus:• Increased energy efficiency/cost savings• New fan motor and enhanced compressor

design• Extended pipe runs/greater installation

flexibility• More steps for precise inverter control• Operating range down to -15°C (cooling) • High-performance heating, even at -15°C• Increased heat exchanger efficiency• All rated A for energy efficiency

• Discharge spigots as standard

• High static pressure up to 98 Pa

• Ideal for R22 replacementSize 564 Size 804 Sizes 1104 and 1404

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 30

Page 31: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

31

Outdoor unit RAV SP404AT-E SP564AT-EIndoor unit (ducted) RAV SM404SDT-E SM564SDT-ERemote control RBC-AMT32E RBC-AMT32E

Cooling capacity range kW 3.6 (1.5-4.0) 5.0 (1.2-5.6) Heating capacity range kW 4.0 (1.5-5.0) 5.6 (0.9-7.4)Power input, cooling/heating kW 1.03/1.00 1.56/1.44EER, cooling/COP heating W/W 3.50/4.00 3.01/3.82Annual power consumption, cooling kWh 515 780Energy label, cooling/heating A/A B/A

UK conditions - cooling capacity kW 3.88 5.44UK conditions - sensible cooling capacity kW 3.20 4.20UK conditions - heating capacity kW 4.93 6.90

Indoor unit (ducted) RAV SM404SDT-E SM564SDT-E

Air flow (low/medium/high) l/s 145/167/192 162/188/217Air flow (low/medium/high) m3/h 522/600/690 582/678/780

Sound pressure level (low/medium/high)** dB(A) 33/36/39 36/40/45Sound power level (low/medium/high) dB(A) 48/51/54 51/55/60

Dimensions, height x width x depth mm 210 x 845 x 645 210 x 845 x 645Weight kg 22 22

Outdoor unit RAV SP404AT-E SP564AT-E

Air flow l/s (m3/h) 667 (2400) 667 (2400)

Sound pressure level, cooling/heating* dB(A) 45/47 47/48Sound power level, cooling/heating dB(A) 62/64 64/65

Dimensions, height x width x depth mm 550 x 780 x 290 550 x 780 x 290Weight kg 40 44

Operating range, cooling °C -15 to 43 -15 to 43Operating range, heating °C -15 to 15 -20 to 15

Pipe connections, gas - liquid in 1/2 - 1/4 1/2 - 1/4Pipe length, maximum/minimum m 30/5 50/5Pipe length, pre-charged m 20 20Additional R410A charge g/m 20 20Maximum height difference, above/below m 30/30 30/30

Max. operating current, cooling A 5.2 724Suggested fuse size A 10 10Power supply V-ph-Hz 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E

Retail price

Indoor unit £ 534.- 545.-Outdoor unit £ 950.- 1015.-System price £ 1536.- 1612.-

Super Digital Inverter Heat Pump Systems, Slim Duct Units

• New 3.6 kW SDI model• New slim 210 mm deep ducted unit design• All ‘A’-rated performance• Unobtrusive installation above a suspended

ceiling or in a bulkhead for a wide range ofapplications

• High-performance operation, using digitalinverter control

• Static pressures up to 45 Pa• Ideal for hotel and residential applications • Extremely quiet operation• Twin-split also available (model 564 only)• Operating range down to -15°C (cooling)

• Ideal for R22 replacementSizes 404 and 564

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 31

Page 32: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

32

Super Digital Inverter Heat Pump Systems, High-Wall Units

Digital Inverter features, plus:• New compact flat-panel design• Increased energy efficiency/cost savings• New fan motor and enhanced compressor

design• Extended pipe runs/greater installation

flexibility• More control steps for more precise inverter

control• Operating range down to -15°C (cooling) • EER values up to 3.80 in cooling mode• High-performance heating, even at -15°C• Increased heat exchanger efficiency• Superior five-stage air filtration system• Ideal for R22 replacement

Outdoor unit RAV SP564AT-E SP804AT-EIndoor unit RAV (high-wall unit) SM562KRT-E SM802KRT-ERemote control Infra-red Infra-red

Cooling capacity range kW 5.0 (1.2-5.6) 6.9 (1.9-8.0)Heating capacity range kW 5.6 (0.9-7.3) 8.0 (1.3-10.6)Power input, cooling/heating kW 1.56/1.55 2.40/2.40EER, cooling/COP, heating W/W 3.14/3.57 2.88/3.33Annual power consumption, cooling kWh 780 1200Energy label, cooling/heating B/B C/C

UK conditions - cooling capacity kW 5.44 7.76UK conditions - sensible cooling capacity kW 4.22 5.85UK conditions - heating capacity kW 4.69 6.70

Indoor unit RAV (high-wall unit) SM562KRT-E SM802KRT-E

Air flow (low/medium/high) l/s 178/208/233 203/243/308Air flow (low/medium/high) m3/h 641/749/839 731/875/1109

Sound pressure level (low/medium/high)* dB(A) 36/41/45 36/41/45Sound power level (low/medium/high) dB(A) 51/56/60 51/56/60

Dimensions, height x width x depth mm 298 x 998 x 221 298 x 998 x 221Weight kg 12 12

Outdoor unit RAV SP564AT-E SP804AT-E

Air flow l/s (m3/h) 667 (2400) 833 (3000)

Sound pressure level, cooling/heating* dB(A) 47/48 48/49Sound power level, cooling/heating dB(A) 64/65 65/66

Dimensions, height x width x depth mm 550 x 780 x 290 890 x 900 x 320Weight kg 44 63

Operating range, cooling °C -15 to 43 -15 to 43Operating range, heating °C -20 to 15 -20 to 15

Pipe connections, gas - liquid in 1/2 - 1/4 5/8 - 3/8Pipe length, maximum(minimum m 50/5 50/5Pipe length, pre-charged m 20 30Additional R410A charge m 20 40Maximum height difference m 30 30

Max. operating current, cooling A 7.24 11.25Suggested fuse size A 10 10Power supply V-ph-Hz 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E

Retail price

Indoor unit £ 388.- 419.-Outdoor unit £ 1015.- 1510.-System price (remote control included) £ 1403.- 1929.-

Size 564 Size 804

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 32

Page 33: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

33

Super Digital Inverter Heat Pump Systems, Ceiling Units

Digital Inverter features, plus:• Increased energy efficiency/cost savings• Slimline design and automatic louvre control

• Enhanced compressor and fan motor design• Extended pipe runs/greater installation

flexibility• More steps for precise inverter control• Operating range down to -15°C (cooling) • EER values up to 4.17 in cooling mode• All units have energy efficiency label A• High-performance heating, even at -15°C• Increased heat exchanger efficiency• Low sound levels, to 30 dB(A)• Ideal for R22 replacement

Outdoor unit RAV SP564AT-E SP804AT-E SP1104AT-E SP1404AT-EIndoor unit (ceiling) RAV SM562CT-E SM802CT-E SM1102CT-E SM1402CT-ERemote control RBC-AMT32E RBC-AMT32E RBC-AMT32E RBC-AMT32E

Cooling capacity range kW 5.0 (1.2-5.6) 7.0 (1.9-8.0) 10.0 (2.6-12.0) 12.5 (2.6-14.0) Heating capacity range kW 5.6 (0.9-7.4) 8.0 (1.3-10.6) 11.2 (2.4-13.0) 14.0 (2.4-16.5)Power input, cooling/heating kW 1.56/1.47 2.21/2.16 2.67/2.62 3.73/3.65EER, cooling/COP, heating W/W 3.06/3.79 3.05/3.66 3.75/4.27 3.35/3.84Annual power consumption, cooling kWh 780 1105 1335 1865Energy label, cooling/heating B/A B/A A/A A/A

UK conditions - cooling capacity kW 5.44 7.76 11.65 13.59UK conditions - sensible cooling capacity kW 4.22 5.85 7.73 8.75UK conditions - heating capacity kW 5.21 7.08 9.68 12.29

Indoor unit (ceiling) RAV SM562CT-E SM802CT-E SM1102CT-E SM1402CT-E

Air flow (low/medium/high) l/s 167/186/217 243/278/308 353/400/458 385/433/500Air flow (low/medium/high) m3/h 601/670/781 875/1001/1109 1271/1440/1649 1386/1559/1800

Sound pressure level (low/medium/high)* dB(A) 30/33/36 33/36/38 35/38/41 37/40/43Sound power level (low/medium/high) dB(A) 45/48/51 48/51/53 50/53/56 52/55/58

Dimensions, height x width x depth mm 210 x 910 x 680 210 x 1180 x 680 210 x 1595 x 680 210 x 1595 x 680Weight kg 21 25 33 33

Outdoor unit RAV SP564AT-E SP804AT-E SP1104AT-E SP1404AT-E

Air flow l/s (m3/h) 667 (2400) 833 (3000) 1683 (6060) 1716 (6180)

Sound pressure level, cooling/heating* dB(A) 47/48 48/49 49/50 51/52Sound power level, cooling/heating dB(A) 64/65 65/66 66/67 68/69

Dimensions, height x width x depth mm 550 x 780 x 290 890 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320Weight kg 44 63 93 93

Operating range, cooling °C -15 to 43 -15 to 43 -15 to 43 -15 to 43Operating range, heating °C -20 to 15 -20 to 15 -15 to 15 -15 to 15

Pipe connections, gas - liquid in 1/2 - 1/4 5/8 - 3/8 5/8 - 3/8 5/8 - 3/8Pipe length, maximum/minimum m 50/5 50/5 75/5 75/5Pipe length, pre-charged m 20 30 30 30Additional R410A charge m 20 40 40 40Maximum height difference m 30 30 30 30

Max. operating current, cooling A 7.24 10.36 11.24 16.21Suggested fuse size A 10 10 20 20Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50Supply to Outdoor unit Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 3 + E 3 + E 3 + E 3 + E

Retail price

Indoor unit £ 655.- 775.- 845.- 1105.-Outdoor unit £ 1015.- 1510.- 1900.- 2100.-System price (remote control included ) £ 1722.- 2337.- 2797.- 3257.-

Size 564 Size 804 Sizes 1104 and 1404

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 33

Page 34: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

34

Super Digital Inverter Twin-Split Systems

• Allows connection of two indoor units (sametype and capacity) to one outdoor unit

• Indoor units are in the same room, operatesimultaneously and have a single controller

• Twin-operation is possible with all light-commercial indoor units (except XT)

• Precise capacity control at all conditions• Ideal for larger shops and open-plan offices• User-friendly controls• Performance tuning for optimised comfort • 95% of SDI systems are A-rated• Remote control is required (RBC-AMT32-E)*• Ideal for R22 replacement* See accessory page for price

Outdoor unit RAV SP1104AT-E SP1404AT-E SP1104AT-E SP1104AT-E SP1404AT-EIndoor unit 2 x 4-way cassette 2 x compact 4-way cassette 2 x ceiling unit

RAV SM564UT-E SM804UT-E SM562MUT-E SM562CT-E SM802CT-E

Cooling capacity range kW 10 (3-12) 12.5 (3-14) 10 (3-12) 10 (3-12) 12.5 (3-14)Heating capacity range kW 11.2 (3-13) 14 (3-16.5) 11.2 (3-13) 11.2 (3-13) 14 (3-16.5)Power input, cooling/heating kW 2,4/2.55 3.56/3.58 2.67/2.67 2.4/2.55 3.9/3.75EER, cooling/COP, heating W/W 4.17/4.39 3.51/3.91 3.75/4.19 3.75/4.27 3.35/3.84Annual power consumption, cooling kWh 1200 1780 1335 1200 1950Energy label, cooling/heating A/A A/A A/A A/A A/A

UK conditions - cooling capacity kW 10.87 13.59 10.87 10.87 13.59UK conditions - sensible cooling capacity kW 6.67 8.86 6.67 6.67 8.86UK conditions - heating capacity kW 9.31 12.29 9.31 9.31 12.29

Retail price

Retail price, indoor units (2 off) £ 1520.- 1812.- 1484.- 1310.- 1550.-Retail price, outdoor unit £ 1900.- 2100.- 1900.- 1900.- 2100.-Retail price, controller (RBC-AMT32E) £ 52.- 52.- 52.- 52.- 52.-Total system price £ 3472.- 3974.- 3436.- 3262.- 3702.-

Outdoor unit RAV SP1104AT-E SP1404AT-E SP1104AT-E SP1104AT-E SP1404AT-EIndoor unit 2 x ducted unit 2 x slim duct unit 2 x high-wall unit

RAV SM562BT-E SM802BT-E SM564SDT-E SM562KRT-E SM802KRT-E

Cooling capacity range kW 10 (3-12) 12.5 (3-14) 10 (3-11.2) 10 (3-12) 12.3 (3-13.5)Heating capacity range kW 11.2 (3-13) 14 (3-16.5) 11.2 (3-12.5) 11.2 (3-13) 14 (3-16.5)Power input, cooling/heating kW 2.5/2.55 3.9/3.6 2.50/2.55 2.4/2.55 4.0/3.85EER, cooling/COP, heating W/W 3.40/4.04 3.26/4.11 4.00/4.39 3.62/4.00 3.17/3.66Annual power consumption, cooling kWh 1250 1950 1250 1200 1950Energy label, cooling/heating A/A A/A A/A A/A B/A

UK conditions - cooling capacity kW 10.87 13.59 10.87 10.87 13.59UK conditions - sensible cooling capacity kW 6.67 8.86 6.67 6.67 8.86UK conditions - heating capacity kW 9.31 12.29 9.68 9.31 12.29

Retail price

Retail price, indoor units (2 off) £ 1170.- 1740.- 1090.- 776.- 838.-Retail price, outdoor unit £ 1900.- 2100.- 1900.- 1900.- 2100.-Retail price, controller (RBC-AMT32E) £ 52.- 52.- 52.- 52.- 52.-Total system price £ 3122.- 3892.- 3042.- 2728.- 2990.-

Outdoor unit RAV SP1104AT-E SP1404AT-E

Air flow l/s (m3/h) 2083 (7500) 2083 (7500)

Sound pressure level, cooling/heating* dB(A) 49/51 53/54Sound power level, cooling/heating dB(A) 66/68 70/71

Dimensions, height x width x depth mm 1340 x 900 x 320 1340 x 900 x 320Weight kg 95 95

Operating range, cooling/heating °C -15 to 43/-15 to 15 -15 to 43/-15 to 15

Pipe connections, gas - liquid in 5/8 - 3/8 5/8 - 3/8Pipe length, maximum/pre-charged m 50/30 50/30Additional R410A charge g/m 40 40Maximum height difference, above/below m 30/30 30/30

Max. operating current, cooling A 11.24 16.51Suggested fuse size A 20 20Power supply (to outdoor unit) V-ph-Hz 220/240-1-50 220/240-1-50Interconnecting cables 3 + E 3 + E

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 34

Page 35: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

35

Super MMS System - Heat Pump Outdoor Units

Rating hp 5 6 8 10 12

Heat pump model MMY MAP0501HT8-E MAP0601HT8-E MAP0801HT8-E MAP1001HT8-E MAP1201HT8-E

Cooling capacity kW 14.0 16.0 22.4 28.0 33.5Heating capacity kW 16.0 18.0 25.0 31.5 37.5Min./max. capacity code* hp 2.5-6.75 3.0-8.1 4.10-8.0 5.0-13.5 6.0-16.2

Power input, cooling/heating kW 3.65/3.84 4.64/4.56 5.67/5.88 7.68/7.97 11.92/10.19Max. running current, cooling/heating A 5.85/6.09 7.28/7.08 8.62/8.93 11.55/11.98 18.30/15.65EER, cooling/COP heating kW/kW 3.84/4.17 3.45/3.95 3.95/4.25 3.65/3.95 2.81/3.68

UK conditions - cooling capacity kW 13.40 15.31 21.44 26.80 32.16UK conditions - sensible cooling capacity kW 10.05 12.06 16.08 20.10 24.12UK conditions - heating capacity kW 12.95 15.54 20.72 25.90 31.08

Max. number of connectable indoor units 8 10 13 16 20

Refrigerant charge R410A, heating kg 8.5 8.5 12.5 12.5 12.5

Sound pressure level, cooling/heating dB(A) at 1 m 55/55 56/56 57/57 58/58 59/59Sound power level, cooling/heating dB(A) 68/68 69/69 70/70 71/71 72/72

Dimensions, height x width x depth mm 1800 x 990 x 750 1800 x 990 x 750 1800 x 990 x 750 1800 x 990 x 750 1800 x 990 x 750Weight kg 228 228 258 258 258

Pipe connectionsSuction line type - diameter in Flare - 5/8 Brazed - 3/4 Brazed - 7/8 Brazed - 7/8 Brazed - 1-1/8Liquid line type - diameter in Flare - 3/8 Flare - 3/8 Flare - 1/2 Flare - 1/2 Flare - 1/2Discharge line connection type - diameter in Flare - 3/8 Flare - 3/8 Flare - 3/8 Flare - 3/8 Flare - 3/8

Maximum equivalent pipe length m 175 175 175 175 175Maximum actual pipe length m 150 150 150 150 150Maximum total pipe length m 300 300 300 300 300Max. height difference - indoor unit above/below** m 40/50 40/50 40/50 40/50 40/50

Operating range, cooling °C -5 to 43 db -5 to 43 db -5 to 43 db -5 to 43 db -5 to 43 dbOperating range, heating °C -20 to 16 wb -20 to 16 wb -20 to 16 wb -20 to 16 wb -20 to 16 wb

Max. operating current per phase A 6.09 7.28 8.93 11.98 18.30Starting current per phase A 1 1 1 1 1Suggested fuse size per phase A 10 10 16 16 20Power supply V-ph-Hz 400-3-50 400-3-50 400-3-50 400-3-50 400-3-50Suppply to Outdoor unit Outdoor unit Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 2-core twisted screened

Retail price

Outdoor unit £ 4284.- 4482.- 5260.- 6236.- 7468.-

* Codes are based on individual units and do not take into consideration modular applications** If the indoor unit is above, maximum lift is reduced to 30 m, if the height difference between indoor units exceeds 3 m.

NOTE: Cooling only models available in UK to special order.

• Modular design, light weight and compactfrom 5 to 48 hp, 14 to 150 kW

• High-efficiency DC twin-inverter compressor

• Indoor unit capacity between 50 and 135% ofthe connected outdoor units

• High EER for reduced energy consumption

• High-lift design, greater location flexibility

• State-of-the-art communication bus system withautomatically configured addressing

• Advanced auto-diagnosis system

• Intelligent control and modulating valves

• Outdoor unit dimensions match the S-HRM

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 35

Page 36: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

36

Super MMS System - Fresh Air Intake Indoor Units

• Three models, air flow range 300 to 583 l/s

• Helps prevent sick building syndrome

• Controls the temperature of the air supply

• Operates as part of S-MMS (up to 30% of thesystem’s capacity

• TCC Link control

• Powerful centrifugal fan with three-speed,single-phase motor

• Heats air as low as -5°C

Rating HP 5 8 10

Models MMD-AP0481HFE MMD-AP0721HFE MMD-AP0961HFE

Cooling capacity kW 14.0 22.4 28.0Heating capacity kW 8.9 13.9 17.4Power input kW 0.28 0.45 0.52

Air flow (high/medium/low) l/s 330/270/210 513/420/327 642/525/408m3/h 1188/972/756 1848/1512/1176 2310/1890/1470

Sound pressure level (high/medium/low) dB(A) 45/43/41 46/45/44 46/45/44Sound power level (high/medium/low) dB(A) 60/58/56 61/60/59 61/60/59

Static pressure (high/medium/low) Pa 230/210/170 180/165/140 205/190/160

Dimensions, height x width x depth mm 492 x 892 x 1262 492 x 1392 x 1262 492 x 1392 x 1262Weight kg 93 144 144

Max. operating current A 1.43 2.52 2.73Starting current A 3.5 7.0 7.0

Power supply V-ph-Hz 220/240-3-50 220/240-3-50 220/240-3-50

Pipe connections, gas - liquid in 5/8 - 3/8 7/8 - 1/2 7/8 - 1/2

Operating range, cooling/heating °C 5 to 43/-5 to 43 5 to 43/-5 to 43 5 to 43/-5 to 43

Retail price

£ 1890.- 3055.- 3228.-

Accessories

Part No. Description Retail price £

TCB-DP31DE Drain Pump Kit (AP0181-0481) 770.-TCB-DP32DE Drain Pump Kit (AP0721-0961) 770.-TCB-FCY21DE Filter Chamber (AP0181) 250.-TCB-FCY31DE Filter Chamber (AP0241-0361) 280.-TCB-FCY51DE Filter Chamber (AP0481) 315.-TCB-FCY100DE Filter Chamber (AP0721-0961) 650.-TCB-PF1D-1E Long Life Prefilter (AP0181(1)/0481(2)) 44.-TCB-PF2D-1E Long Life Prefilter (AP0241-0361(2)) 44.-TCB-PF3DE Long Life Prefilter (AP0721-0961) 140.-TCB-UFM1D-1E High Efficiency Filter 65 (AP0181(1)/0481(2)) 140.-TCB-UFM2D-1E High Efficiency Filter 65 (AP0241-0361(2)) 105.-TCB-UFM3DE High Efficiency Filter 65 (AP0721-0961H) 440.-TCB-UFH5D-1E High Efficiency Filter 90 (AP0181(1)/0481(2)) 145.-TCB-UFH6D-lE High Efficiency Filter 90 (AP0241-0361(2)) 145.-TCB-UFH7DE High Efficiency Filter 90 (AP0721-0961) 480.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 36

Page 37: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

37

S-HRM System - VRF Heat Recovery Outdoor Units

• Low weight, compact design

• 48 modular indoor units maximum, 8 to 30 hpto be combined with up to 135% of the outdoorunit capacity

• Superior EER for reduced energy consumptionand increased savings

• High-lift design, greater location flexibility

• State-of-the-art communication bus system withautomatically configured addressing

• Outdoor unit dimensions match the S-MMS

• Added flexibility and control with flow selectorsand piping branches

HRM

Rating hp 8 10 12

Heat recovery model MMY MAP0802FT8-E MAP1002FT8-E MAP1202FT8-E

Cooling capacity kW 22.4 28.0 33.5Heating capacity kW 25.0 31.5 35.5Min.-max. capacity code* hp 5.6-10.8 7.0-13.5 8.4-14.4

Power input, cooling/heating kW 6.07/6.29 8.54/8.73 12.90/9.65Max. running current, cooling/heating A 9.25/9.55 13.15/13.40 19.85/14.85EER, cooling/COP heating kW/kW 3.69/3.97 3.28/3.61 2.60/3.68

Sound pressure level, cooling/heating dB(A) at 1 m 57/57 58/58 59/59Sound power level, cooling/heating dB(A) 70/70 71/71 72/72

UK conditions - cooling capacity kW 21.44 26.80 32.16UK conditions - sensible cooling capacity kW 16.08 20.10 24.12UK conditions - heating capacity kW 20.72 25.90 31.08

Refrigerant charge R410A kg 11.5 11.5 11.5

Dimensions, height x width x depth mm 1800 x 990 x 750 1800 x 990 x 750 1800 x 990 x 750Weight kg 263 263 263

PipeworkSuction line type - diameter in Brazed - 7/8 Brazed - 7/8 Brazed - 1-1/8Liquid line type - diameter in Flare - 1/2 Flare - 1/2 Flare - 1/2Discharge line connection type - diameter in Flare - 3/4 Flare - 3/4 Flare - 3/4

Maximum equivalent pipe length m 150 150 150Maximum actual pipe length m 125 125 125Maximum total pipe length m 300 300 300Max. height difference - indoor unit above/below** m 30/50 30/50 30/50

Operating range, cooling °C -5 to 43 db -5 to 43 db -5 to 43 dbOperating range, heating °C -20 to 16 wb -20 to 16 wb -20 to 16 wb

Max. operating current per phase A 9.55 13.40 19.85Starting current per phase A 1 1 1Suggested fuse size per phase A 16 20 25Power supply V-ph-Hz 400-3-50 400-3-50 400-3-50Suppply to Outdoor unit Outdoor unit Outdoor unitInterconnecting cables 2-core twisted screened 2-core twisted screened 2-core twisted screened

* Codes are based on individual units and do not take into consideration modular applications** If the indoor unit is above, maximum lift is reduced to 30 m, if the height difference between indoor units exceeds 3 m.

Retail price

Outdoor unit £ 6212.- 6756.- 8258.-

Flow selector Capacity, kW Max. No. of connected units Retail price £

Y1122FE 0 to 11.2 5 442.-

Y1802FE 11.2 to 18.0 8 490.-

Y2802FE 18.0 to 28.0 8 770.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 37

Page 38: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

38

MiNi-SMMS System - VRF Heat Pump Outdoor Units

• Single phase power supply

• Compact and light-weight outdoor unit

• High-efficiency DC twin rotary compressor

• Best COP in the industry: 4.61• Capacity range 12-15.5 kW cooling and 12-

18 kW heating

• Automatic addressing

• Extended refrigerant piping capability

• Operates up to nine indoor units from a choiceof over 80

• Ultra-quiet, utilising remote PMV kit (option)

• All systems achieve energy efficiency class A

Rating hp 4 5 6

Heat pump model MCY MAP0401HT MAP0501HT MAP0601HT

Cooling capacity kW 12.1 14.0 15.5Heating capacity kW 12.5 16.0 18.0Min.-max. capacity code** hp 3.2-5.2 4.0-6.5 4.3-7.8

Power input, cooling/heating kW 2.82/2.71 3.47/4.0 4.63/4.85Max. running current, cooling/heating A 13.2/12.5 16.1/18.3 21.4/22.2EER, cooling/COP heating kW/kW 4.29/4.61 4.03/4.00 3.35/3.71Energy label, cooling/heating A/A A/A A/A

Sound pressure level, cooling/heating dB(A) at 1 m 49/50 50/52 51/53Sound power level, cooling/heating dB(A) 62/63 63/65 64/66

UK conditions - cooling capacity kW 11.59 13.42 14.35UK conditions - sensible cooling capacity kW 8.70 10.06 11.14UK conditions - heating capacity kW 10.12 12.96 14.58

Refrigerant charge R410A kg 7.2 7.2 7.2

Dimensions, height x width x depth mm 1340 x 900 x 320 1340 x 900 x 320 1340 x 900 x 320Weight kg 117 117 117

PipeworkSuction line type - diameter in Brazed - 5/8 Brazed - 5/8 Brazed - 3/4Liquid line type - diameter in Flare - 3/8 Flare - 3/8 Flare - 3/8

Maximum equivalent pipe length m 125 125 125Maximum actual pipe length m 100 100 100Maximum total pipe length m 180 180 180Max. height difference - indoor unit below/above** m 30/20 30/20 30/20

Operating range, cooling °C -10 to 43 db -10 to 43 db -10 to 43 dbOperating range, heating °C -15 to 20 wb -15 to 20 wb -15 to 20 wb

Max. operating current per phase A 13.8 19.1 23.2Starting current per phase A 1 1 1Suggested fuse size per phase A 16 25 25Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50Suppply to Outdoor + indoor unit Outdoor + indoor unit Outdoor + indoor unitInterconnecting cables 2-core twisted screened 2-core twisted screened 2-core twisted screened

* Codes are based on individual units and do not take into consideration modular applications** If the indoor unit is above, maximum lift is reduced to 30 m, if the height difference between indoor units exceeds 3 m.

*** Compatable with 3 senes high wall units only

Retail price

Outdoor unit £ 3640.- 4135.- 4450.-

External PMV valve Capacity, kW Retail price, £

RBM-PMV0361E 2.2-3.6 150.-

RBM-PMV0901E 4.5-5.0 162.-

RBM-PMV0362E*** 2.2-3.6 150.-

RBM-PMV0902E*** 4.5-5.0 162.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 38

Page 39: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

39

VRF Indoor units - 4-Way Cassettes

• Unobtrusive and flexible, blends in with anyroom decor

• Four-way adjustable grille

• Innovative air flow control and new paneldesign prevent dust accumulation on the ceiling

• Louvre and grille are easily detachable

• Corner pockets in all four corners for easyaccess

• Flexible installation - ideal for sites withrestricted space above the ceiling

• High-lift drain pump (850 mm)

Indoor unit MMU AP0092H AP0122H AP0152H AP0182H AP0242HFascia panel RBC-U31PG(W)-E RBC-U31PG(W)-E RBC-U31PG(W)-E RBC-U31PG(W)-E RBC-U31PG(W)-E

Capacity code hp 1 1.25 1.7 2 2.5Cooling capacity kW 2.8 3.6 4.5 5.6 7.1Heating capacity kW 3.2 4.0 5.0 6.3 8.0Power input kW 0.021 0.021 0.023 0.026 0.036

Air flow (high/medium/low) l/s 222/203/189 222/203/189 258/231/219 292/256/222 358/256/222Air flow (high/medium/low) m3/h 800/730/680 800/730/680 930/830/790 1050/920/800 1290/920/800

Sound pressure level (high/medium/low) dB(A) 30/29/27 30/29/27 31/29/27 32/29/27 35/31/28Sound power level (high/medium/low) dB(A) 45/44/42 45/44/42 46/44/42 47/44/42 50/46/43

Dimensions, height x width x depth mm 256 x 840 x 840 256 x 840 x 840 256 x 840 x 840 256 x 840 x 840 256 x 840 x 840Weight kg 18 18 20 20 20

Max. operating current A 0.23 0.23 0.27 0.29 0.38Starting current A 0.30 0.30 0.33 0.36 0.42Suggested fuse size A 3 3 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 988.- 1018.- 1073.- 1133.- 1175.-

Indoor unit MMU AP0272H AP0302H AP0362H AP0482H AP0562HFascia panel RBC-U31PG(W)-E RBC-U31PG(W)-E RBC-U31PG(W)-E RBC-U31PG(W)-E RBC-U31PG(W)-E

Capacity code hp 3 3.2 4 5 6Cooling capacity kW 8.0 9.0 11.2 14.0 16.0Heating capacity kW 9.0 10.0 12.5 16.0 18.0Power input kW 0.036 0.043 0.088 0.112 0.112

Air flow (high/medium/low) l/s 358/256/222 367/308/236 547/397/297 592/397/314 592/422/342Air flow (high/medium/low) m3/h 1290/920/800 1320/1110/850 1970/1430/1070 2130/1430/1130 2130/1520/1230

Sound pressure level (high/medium/low) dB(A) 35/31/28 38/33/30 48/38/32 46/38/33 45/40/34Sound power level (high/medium/low) dB(A) 50/46/43 53/48/45 58/53/47 61/53/48 61/53/48

Dimensions, height x width x depth mm 256 x 840 x 840 256 x 840 x 840 319 x 840 x 840 319 x 840 x 840 319 x 840 x 840Weight kg 20 20 25 25 25

Max. operating current A 0.38 0.43 0.73 0.88 0.92Starting current A 0.42 0.59 0.88 1.23 1.23Suggested fuse size A 3 3 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 1262.- 1383.- 1480.- 1641.- 1808.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 39

Page 40: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

40

VRF Indoor units - Compact 600 x 600 mm, 4-Way Cassettes

• Suits standard 600 x 600 mm grid ceilings toallow easy installation and maintenance

• New louvre design

• Easy control access via corner pockets

• All capacity sizes have the same dimensions

• Panel depth less than 30 mm for sleek,unobtrusive installation

• TCC Link control panel for flexible, easy systemcontrol

• Compatible with all Toshiba VRF systems

Indoor unit MMU AP0071MH AP0091MH AP0121MH AP0151MH AP0181MHFascia panel RBC-UM11PG(W)-ERBC-UM11PG(W)-E RBC-UM11PG(W)-E RBC-UM11PG(W)-E RBC-UM11PG(W)-E

Capacity code hp 0.8 1 1.25 1.7 2Cooling capacity kW 2.2 2.8 3.6 4.5 5.6Heating capacity kW 2.5 3.2 4.0 5.0 6.3Power input kW 0.034 0.036 0.038 0.041 0.052

Air flow (high/medium/low) l/s 153/128/105 158/130/105 165/140/112 183/153/130 212/178/153Air flow (high/medium/low) m3/h 551/460/378 569/468/378 594/504/403 659/551/468 763/641/522

Sound pressure level (high/medium/low) dB(A) 36/32/28 37/33/28 37/33/29 40/35/30 44/39/34Sound power level (high/medium/low) dB(A) 49/45/41 50/46/41 50/46/42 53/48/43 57/52/47

Dimensions, height x width x depth mm 268 x 575 x 575 268 x 575 x 575 268 x 575 x 575 268 x 575 x 575 268 x 575 x 575Weight kg 20 20 20 20 20

Max. operating current A 0.28 0.30 0.31 0.34 0.42Starting current A 0.49 0.52 0.54 0.59 0.73Suggested fuse size A 3 3 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 918.- 942.- 966.- 1047.- 1104.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:02 Page 40

Page 41: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

41

VRF Indoor units - 2-Way Cassettes

• Compact size, ideal for small rooms

• Discreet and slim design, 8 mm ceiling panel

• Easy to install, fits any interior decor

• User-friendly controls

• Exceptionally quiet operation to 30 dB(A)

• Unique air flow control, balanced air flow foroptimised comfort

• Condensate drain pump with 500 mm lift

• Enhanced indoor air quality: standard long-lifefilters and fresh air intake for constant airrenewal

Indoor unit MMU AP0071WH AP0091WH AP0121WH AP0151WH AP0181WHFascia panel RBC-UW136PG RBC-UW136PG RBC-UW136PG RBC-UW266PG RBC-UW266PG

Capacity code hp 0.8 1 1.25 1.7 2Cooling capacity kW 2.2 2.8 3.6 4.5 5.6Heating capacity kW 2.5 3.2 4.0 5.0 6.3Power input kW 0.070 0.070 0.070 0.072 0.072

Air flow (high/medium/low) l/s 158/142/125 158/142/125 158/142/125 217/195/167 217/195/167Air flow (high/medium/low) m3/h 570/510/450 570/510/450 570/510/450 780/700/600 780/700/600

Sound pressure level (high/medium/low) dB(A) 34/32/30 34/32/30 34/32/30 35/33/30 35/33/30Sound power level (high/medium/low) dB(A) 47/45/43 47/45/43 47/45/43 48/46/43 48/46/43

Dimensions, height x width x depth mm 398 x 830 x 550 398 x 830 x 550 398 x 830 x 550 398 x 1350 x 550 398 x 1350 x 550Weight kg 33 33 33 44 44

Max. operating current A 0.31 0.31 0.31 0.32 0.32Starting current A 0.47 0.47 0.47 0.60 0.60Suggested fuse size A 3 3 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 1056.- 1088.- 1116.- 1211.- 1291.-

Indoor unit MMU AP0241WH AP0271WH AP0301WHFascia panel RBC-UW266PG RBC-UW266PG RBC-UW266PG

Capacity code hp 2.5 3 3.2Cooling capacity kW 7.1 8.0 9.0Heating capacity kW 8.0 9.0 10.0Power input kW 0.105 0.105 0.106

Air flow (high/medium/low) l/s 317/267/200 317/267/200 350/317/267Air flow (high/medium/low) m3/h 1140/960/720 1140/960/720 1260/1140/960

Sound pressure level (high/medium/low) dB(A) 38/35/33 38/35/33 40/37/34Sound power level (high/medium/low) dB(A) 51/48/46 51/48/46 53/50/47

Dimensions, height x width x depth mm 398 x 1350 x 550 398 x 1350 x 550 398 x 1350 x 550Weight kg 48 48 48

Max. operating current A 0.46 0.46 0.47Starting current A 0.89 0.89 0.98Suggested fuse size A 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 1373.- 1518.- 1563.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 41

Page 42: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

42

VRF Indoor units - 1-Way Cassettes

• Compact high-tech slimline design

• Flexible installation - ideal for sites withrestricted space above the ceiling

• High-lift drain pump (350 mm)

• Low noise level - 34 dB(A)

• User-friendly control

• Ideal for hotels, offices and reception rooms

Indoor unit MMU AP0071YH AP0091YH AP0121YHFascia panel RBC-UY136PG RBC-UY136PG RBC-UY136PG

Capacity code hp 0.8 1 1.25Cooling capacity kW 2.2 2.8 3.6Heating capacity kW 2.5 3.2 4.0Power input kW 0.053 0.053 0.053

Air flow (high/medium/low) l/s 150/133/117 150/133/117 150/133/117Air flow (high/medium/low) m3/h 540/480/420 540/480/420 540/480/420

Sound pressure level (high/medium/low) dB(A) 42/39/34 42/39/34 42/39/34Sound power level (high/medium/low) dB(A) 55/52/47 55/52/47 55/52/47

Dimensions, height x width x depth mm 235 x 850 x 400 235 x 850 x 400 235 x 850 x 400Weight kg 22 22 22

Max. operating current A 0.24 0.24 0.24Starting current A 0.6 0.6 0.6Suggested fuse size A 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 1209.- 1269.- 1299.-

Indoor unit MMU AP0152SH AP0182SH AP0242SHFascia panel RBC-US21PGE RBC-US21PGE RBC-US21PGE

Capacity code hp 1.7 2 2.5Cooling capacity kW 4.5 5.6 7.1Heating capacity kW 5.0 6.3 8.0Power input kW 0.103 0.103 0.115

Air flow (high/medium/low) l/s 217/200/183 217/200/183 333/317/283Air flow (high/medium/low) m3/h 780/720/660 780/720/660 1200/1140/1020

Sound pressure level (high/medium/low) dB(A) 42/39/35 42/39/35 43/41/37Sound power level (high/medium/low) dB(A) 55/52/48 55/52/48 56/54/50

Dimensions, height x width x depth mm 198 x 1000 x 655 198 x 1000 x 655 198 x 1200 x 655Weight kg 27 27 31

Max. operating current A 0.48 0.48 0.55Starting current A 0.8 0.8 1.1Suggested fuse size A 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 1318.- 1428.- 1498.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 42

Page 43: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

43

• Precise capacity control at all conditions

• Slim-line grille (25 mm)

• Adjustable air distribution via remote controller

• Compact unit - only 210 mm void spacerequired

• Performance tuning for optimised comfort

• Easy installation and maintenance with long-lifewashable filter

• Quiet operation with automatic air flow control

• 850-mm lift pump

VRF Indoor units - Slim Duct Units

Indoor unit MMD AP0071SPH AP0091SPH AP0121SPH

Capacity code hp 0.8 1 1.25Cooling capacity kW 2.2 2.8 3.6Heating capacity kW 2.5 3.2 4.0Power input kW 0.039 0.039 0.043

Air flow (high/medium/low) l/s 150/131/111 150/131/111 167/144/125Air flow (high/medium/low) m3/h 540/470/400 540/470/400 600/520/450

Sound pressure level, bottom air inlet (h/m/l)dB(A) 36/33/30 36/33/30 38/35/32Sound power level, bottom air inlet (h/m/l) dB(A) 55/52/47 55/52/47 55/52/47

Sound pressure level, rear air inlet (h/m/l) dB(A) 28/26/24 28/26/24 29/27/25Sound power level, rear air inlet (h/m/l) dB(A) 43/41/39 43/41/39 42/40/38

Dimensions, height x width x depth mm 210 x 845 x 645 210 x 845 x 645 210 x 845 x 645Weight kg 22 22 22

Max. operating current A 0.29 0.29 0.31Starting current A 0.51 0.51 0.54Suggested fuse size A 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 710.- 730.- 750.-

Indoor unit MMD AP0151SPH AP0181SPH

Capacity code hp 1.7 2Cooling capacity kW 4.5 5.6Heating capacity kW 5.0 6.3Power input kW 0.045 0.054

Air flow (high/medium/low) l/s 192/167/144 217/189/161Air flow (high/medium/low) m3/h 690/600/520 780/680/580

Sound pressure level, bottom air inlet (h/m/l)dB(A) 39/36/33 40/38/36Sound power level, bottom air inlet (h/m/l) dB(A) 55/52/48 55/52/48

Sound pressure level, rear air inlet (h/m/l) dB(A) 32/30/28 33/31/29Sound power level, rear air inlet (h/m/l) dB(A) 47/45/43 48/46/44

Dimensions, height x width x depth mm 210 x 845 x 645 210 x 845 x 645Weight kg 23 23

Max. operating current A 0.32 0.39Starting current A 0.56 0.68Suggested fuse size A 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 770.- 790.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 43

Page 44: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

44

Indoor unit MMD AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH

Capacity code hp 0.8 1 1.25 1.7 2 2.5Cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1Heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0Power input kW 0.033 0.033 0.039 0.039 0.050 0.060

Air flow (high/medium/low) l/s 133/117/95 133/117/95 158/136/111 181/150/133 217/183/150 317/275/242Air flow (high/medium/low) m3/h 480/420/340 480/420/340 570/490/400 650/540/480 780/660/540 1140/990/870

Sound pressure level (high/medium/low) dB(A) 30/28/26 30/28/26 31/29/27 31/29/27 32/30/28 33/31/29Sound power level (high/medium/low) dB(A) 43/41/39 43/41/39 44/42/40 44/42/40 45/43/41 46/44/42

Dimensions, height x width x depth mm 320 x 550 x 800 320 x 550 x 800 320 x 550 x 800 320 x 700 x 800 320 x 700 x 800 320 x 1000 x 800Weight kg 28 28 28 32 32 43

Max. operating current A 0.29 0.29 0.34 0.34 0.43 0.52Starting current A 0.50 0.50 0.59 0.59 0.75 0.90Suggested fuse size A 3 3 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 700.- 710.- 760.- 790.- 900.- 940.-

Indoor unit MMD AP0271BH AP0301BH AP0361BH AP0481BH AP0561BH

Capacity code hp 3 3.2 4 5 6Cooling capacity kW 8.0 9.0 11.2 14.0 16.0Heating capacity kW 9.0 10.0 12.5 16.0 18.0Power input kW 0.060 0.071 0.107 0.128 0.128

Air flow (high/medium/low) l/s 317/275/242 350/300/242 450/392/333 550/475/414 550/475/414Air flow (high/medium/low) m3/h 1140/990/870 1260/1080/870 1620/1410/1200 1980/1710/1490 1980/1710/1490

Sound pressure level (high/medium/low) dB(A) 33/31/29 34/32/29 36/34/32 38/36/32 38/36/32Sound power level (high/medium/low) dB(A) 46/44/42 47/45/42 49/47/45 51/49/45 51/49/45

Dimensions, height x width x depth mm 320 x 1000 x 800 320 x 1000 x 800 320 x 1350 x 800 320 x 1350 x 800 320 x 1350 x 800Weight kg 43 43 55 55 55

Max. operating current A 0.52 0.61 0.83 0.98 0.98Starting current A 0.90 1.05 1.44 1.70 1.70Suggested fuse size A 3 3 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 1010.- 1080.- 1235.- 1320.- 1445.-

VRF Indoor units - Standard Ducted Units

• Unit can be easily installed in ceiling voids orfalse ceilings

• Whisper-quiet operation

• Uniform temperature and air distribution for anyroom shape

• Enhanced indoor air quality for optimumoccupant comfort

• Wide range of filters and fresh air intake forconstant air renewal

• Space-saving design; only 320 mm high

• High-lift drain pump (270 mm)

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 44

Page 45: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

45

VRF Indoor units - Ceiling-Suspended Units

• Ideal solution for fixed ceiling designs

• Slim-line space-saving design

• Uniform air distribution for a pleasant andrelaxing environment

• Easy and fast installation - simple unitsuspension

• High-lift drain pump (600 mm) optional

• Optimised louvre control

• Flexible piping (from top, rear or side of theunit)

Indoor unit MMC AP0151H AP0181H AP0241H

Capacity code hp 1.7 2 2.5Cooling capacity kW 4.5 5.6 7.1Heating capacity kW 5.0 6.3 8.0Power input kW 0.033 0.038 0.050

Air flow (high/medium/low) l/s 200/167/150 217/183/150 308/250/233Air flow (high/medium/low) m3/h 720/600/540 780/660/540 1110/900/840

Sound pressure level (high/medium/low) dB(A) 35/32/30 36/33/30 38/36/33Sound power level (high/medium/low) dB(A) 48/45/43 49/46/43 51/49/46

Dimensions, height x width x depth mm 210 x 910 x 680 210 x 910 x 680 210 x 1180 x 680Weight kg 22 22 26

Max. operating current A 0.29 0.32 0.42Starting current A 0.43 0.48 0.62Suggested fuse size A 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 1145.- 1260.- 1330.-

Indoor unit MMC AP0271H AP0361H AP0481H

Capacity code hp 3 4 5Cooling capacity kW 8.0 11.2 14.0Heating capacity kW 9.0 12.5 16.0Power input kW 0.050 0.091 0.110

Air flow (high/medium/low) l/s 308/250/233 458/383/333 500/433/367Air flow (high/medium/low) m3/h 1110/900/840 1650/1380/1200 1800/1560/1320

Sound pressure level (high/medium/low) dB(A) 38/36/33 41/38/35 43/40/37Sound power level (high/medium/low) dB(A) 51/49/46 54/51/48 56/53/50

Dimensions, height x width x depth mm 210 x 1180 x 680 210 x 1595 x 680 210 x 1595 x 680Weight kg 26 34 34

Max. operating current A 0.42 0.78 0.84Starting current A 0.62 1.17 1.25Suggested fuse size A 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 1350.- 1370.- 1400.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 45

Page 46: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

46

VRF Indoor units - High Static Pressure Ducted Units

• Extremely powerful ducted model

• Flexible and compact design

• Unobtrusive installation in the ceiling void

• Ideal solution for both new and refurbishedbuildings

• Simple and fast installation

• Inspection hole allows access for easymaintenance

• Static pressure from 68 to 196 Pa

Indoor unit MMD AP0181H AP0241H AP0271H AP0361H AP0481H

Capacity code hp 2 2.5 3 4 5Cooling capacity kW 5.6 7.1 8.0 11.2 14.0Heating capacity kW 6.3 8.0 9.0 12.5 16.0Power input kW 0.184 0.299 0.299 0.368 0.414

Air flow (high/medium/low) l/s 300/250/200 439/367/295 439/367/295 533/445/356 700/583/467Air flow (high/medium/low) m3/h 1080/900/720 1580/1320/1060 1580/1320/1060 1920/1600/1280 2520/2100/1680

Sound pressure level (high/medium/low) dB(A) 37/35/33 40/38/36 40/38/36 40/38/36 40/38/36Sound power level (high/medium/low) dB(A) 50/48/46 53/51/49 53/51/49 53/51/49 53/51/49

Dimensions, height x width x depth mm 380 x 850 x 660 380 x 850 x 660 380 x 850 x 660 380 x 850 x 660 380 x 1200 x 660Weight kg 50 52 52 56 67

Max. operating current A 0.81 1.35 1.35 1.63 1.84Starting current A 1.3 3.5 .3.5 4.1 4.8Suggested fuse size A 3 5 5 5 10Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 1229.- 1282.- 1457.- 1641.- 1772.-

Indoor unit MMU AP0721H AP0961H

Capacity code hp 8 10Cooling capacity kW 22.4 28.0Heating capacity kW 25.0 31.5Power input kW 1.200 1.260

Air flow (high/medium/low) l/s 1200/1000/800 1400/1167/933Air flow (high/medium/low) m3/h 4320/3600/2880 5040/4200/3360

Sound pressure level (high/medium/low) dB(A) 49/47/45 50/48/46Sound power level (high/medium/low) dB(A) 62/60/58 63/61/59

Dimensions, height x width x depth mm 470 x 1380 x 1250 470 x 1380 x 1250Weight kg 150 150

Max. operating current A 5.25 5.52Starting current A 13.6 14.8Suggested fuse size A 16 16Power supply V-ph-Hz 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 2784.- 2996.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 46

Page 47: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

47

VRF Indoor units - High-Wall Units

• Elegant, slim-line design, blends in with anyroom decor

• Compact unit with only 228 mm depth

• Installation on the wall, saving valuable floorspace

• Easy and rapid installation

• Flexible piping to base, rear or side of the unit

• Auto-swing louvre feature for optimal airdistribution and maximised personal comfort

Indoor unit MMK AP0073H AP0093H AP0123H AP0153H AP0183H AP0243H

Capacity code hp 0.8 1 1.25 1.7 2 2.5Cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1Heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0Power input kW 0.018 0.021 0.021 0.043 0.043 0.050

Air flow (high/medium/low) l/s 158/125/108 167/133/108 167/133/108 233/183/150 233/183/150 283/208/158Air flow (high/medium/low) m3/h 570/450/390 600/480/390 600/480/390 840/660/540 840/660/540 1020/750/570

Sound pressure level (h/m/l) dB(A) 35/32/29 36/33/29 37/33/29 42/38/35 42/38/35 42/38/35Sound power level (h/m/l) dB(A) 48/46/42 49/47/42 50/47/42 55/51/48 55/51/48 55/51/48

Dimensions, height x width x depth mm 320 x 1050 x 228 320 x 1050 x 228 320 x 1050 x 228 320 x 1050 x 228 320 x 1050 x 228 320 x 1050 x 228Weight kg 15 15 15 15 15 17

Max. operating current A 0.17 0.19 0.19 0.32 0.32 0.37Starting current A 0.22 0.24 0.24 0.41 0.41 0.47Suggested fuse size A 3 3 3 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 560.- 565.- 570.- 675.- 690.- 700.-

Indoor unit MMK AP0072H AP0092H AP0122H

Capacity code hp 0.8 1 1.25Cooling capacity kW 2.2 2.8 3.6Heating capacity kW 2.5 3.2 4.0Power input kW 0.017 0.018 0.019

Air flow (high/medium/low) l/s 133/117/100 142/125/100 150/125/100Air flow (high/medium/low) m3/h 480/420/360 510/450/360 540/450/360

Sound pressure level (h/m/l) dB(A) 35/32/29 36/33/29 37/33/29Sound power level (h/m/l) dB(A) 48/46/42 49/47/42 50/47/42

Dimensions, height x width x depth mm 275 x 790 x 208 275 x 790 x 208 275 x 790 x 208Weight kg 11 11 11

Max. operating current A 0.17 0.18 0.19Starting current A 0.22 0.23 0.24Suggested fuse size A 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 560.- 565.- 570.-

Sizes 72-122

Sizes 73-243

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 47

Page 48: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

48

VRF Indoor units - Floor-Mounted Console Units

• Suitable for refurbishment projects/smallspaces

• Flexible refrigerant and drain piping (base,rear, left or right-hand side of the unit)

• Air distribution can be from front or top to suitthe occupant’s individual comfort requirements

• Wide choice of applications possible

• Compact space-saving unit design

• Rapid and flexible installation

Indoor unit MML AP0071H AP0091H AP0121H AP0151H AP0181H AP0241H

Capacity code hp 0.8 1 1.25 1.7 2 2.5Cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1Heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0Power input kW 0.056 0.056 0.092 0.092 0.102 0.102

Air flow (high/medium/low) l/s 133/117/100 133/117/100 250/217/181 250/217/181 300/258/217 300/258/217Air flow (high/medium/low) m3/h 480/420/360 480/420/360 900/780/650 900/780/650 1080/930/780 1080/930/780

Sound pressure level (high/medium/low) dB(A) 39/37/35 39/37/35 45/41/38 45/41/38 49/44/39 49/44/39Sound power level (high/medium/low) dB(A) 52/50/48 52/50/48 58/54/51 58/54/51 62/57/52 62/57/52

Dimensions, height x width x depth mm 630 x 950 x 230 630 x 950 x 230 630 x 950 x 230 630 x 950 x 230 630 x 950 x 230 630 x 950 x 230Weight kg 37 37 37 37 40 40

Max. operating current A 0.26 0.26 0.43 0.43 0.47 0.47Starting current A 0.60 0.60 0.80 0.80 1.10 1.10Suggested fuse size A 3 3 3 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 890.- 910.- 935.- 980.- 1040.- 1100.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 48

Page 49: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

49

VRF Indoor units - Concealed Chassis Units

• The perfect solution for perimeter walls

• Can be hidden behind a decorative panel toblend in with any room surroundings

• Ideal for offices, libraries, hospitals andcommercial buildings with large loadfluctuations

• Extremely compact design, saving valuablespace

• Low operating noise level - to 32 dB(A)

• Easy maintenance: removable split front paneland easy access from the right-hand side

Indoor unit MML AP0071BH AP0091BH AP0121BH AP0151BH AP0181BH AP0241BH

Capacity code hp 0.8 1 1.25 1.7 2 2.5Cooling capacity kW 2.2 2.8 3.6 4.5 5.6 7.1Heating capacity kW 2.5 3.2 4.0 5.0 6.3 8.0Power input kW 0.056 0.056 0.056 0.090 0.090 0.095

Air flow (high/medium/low) l/s 128/111/83 128/111/83 128/111/83 206/167/136 206/167/136 264/220/178Air flow (high/medium/low) m3/h 460/400/300 460/400/300 460/400/300 740/600/490 740/600/490 950/790/640

Sound pressure level (high/medium/low) dB(A) 36/34/32 36/34/32 36/34/32 36/34/32 36/34/32 42/37/33Sound power level (high/medium/low) dB(A) 49/47/45 49/47/45 49/47/45 49/47/45 49/47/45 55/50/46

Dimensions, height x width x depth mm 600 x 745 x 220 600 x 745 x 220 600 x 745 x 220 600 x 1045 x 220600 x 1045 x 220 600 x 1045 x 220Weight kg 21 21 21 29 29 29

Max. operating current A 0.25 0.25 0.25 0.45 0.45 0.46Starting current A 0.60 0.60 0.60 0.80 0.80 1.00Suggested fuse size A 3 3 3 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 790.- 810.- 835.- 875.- 930.- 965.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 49

Page 50: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

50

Indoor unit MMF AP0151H AP0181H AP0241H AP0271H

Capacity code hp 1.7 2 2.5 3Cooling capacity kW 4.5 5.6 7.1 8.0Heating capacity kW 5.0 6.3 8.0 9,0Power input kW 0.150 0.150 0.190 0.190

Air flow (high/medium/low) l/s 250/217/183 250/217/183 333/283/233 333/283/233Air flow (high/medium/low) m3/h 900/780/660 900/780/660 1200/1020/840 1200/1020/840

Sound pressure level (high/medium/low) dB(A) 46/43/38 46/43/38 49/45/40 49/45/40Sound power level (high/medium/low) dB(A) 59/56/51 59/56/51 62/58/53 62/58/53

Dimensions, height x width x depth mm 1750 X 600 X 210 1750 X 600 X 210 1750 X 600 X 210 1750 X 600 X 210Weight kg 48 48 49 49

Max. operating current A 0.67 0.67 0.88 0.88Starting current A 0.90 0.90 1.10 1.10Suggested fuse size per phase A 3 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 1350.- 1400.- 1470.- 1520.-

Indoor unit MMF AP0361H AP0481H AP0561H

Capacity code hp 4 5 6Cooling capacity kW 11.2 14.0 16.0Heating capacity kW 12.5 16.0 18.0Power input kW 0.280 0.350 0.350

Air flow (high/medium/low) l/s 533/467/383 600/517/433 600/517/433Air flow (high/medium/low) m3/h 1920/1680/1380 2160/1860/1560 2160/1860/1560

Sound pressure level (high/medium/low) dB(A) 51/48/44 54/50/46 54/50/46Sound power level (high/medium/low) dB(A) 64/61/57 67/63/59 67/63/59

Dimensions, height x width x depth mm 1750 X 600 X 390 1750 X 600 X 390 1750 X 600 X 390Weight kg 65 65 65

Max. operating current A 1.29 1,60 1.60Starting current A 1.70 2.10 2.10Suggested fuse size per phase A 3 3 3Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50

Retail price

Indoor unit £ 1560.- 1630.- 1720.-

• Compact space-saving dimensions

• Ideal for air conditioning of large rooms withlow ceilings

• Units offer high air flow rates and superior airthrow values

• Wide air distribution angle to reach everycorner of the room

• Large capacity range from 4.5 kW to 16 kWcooling and 5 kW to 18 kW heating

VRF Indoor units - Floor-Mounted Cabinet Units

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 50

Page 51: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

51

Model VN-250TE VN-350TE VN-500TE VN-800TE VN-1KTAE

Air flow rate, high l/s (m3/h) 69 (250) 97 (350) 139 (500) 222 (800) 278 (1000)Air flow rate, low l/s (m3/h) 47 (170) 78 (280) 103 (370) 181 (650) 225 (810)

Temperature exchange efficiency (EH/H/L) % 75/75/77 75/75/77 75/75/77 75/75/76 75/75/76

Input power (EH/H/L) WHeat reclaim mode 119/114/90 154/137/128 214/188/166 347/329/327 445/399/367Bypass mode 119/114/90 151/132/125 210/182/164 337/325/316 438/392/362

Enthalpy exchange efficiency (EH/H/L)Heating % 70/70/73 69/69/71 67/67/71 71/71/74 71/71/73Cooling % 63/63/66 66/66/69 62/62/67 65/65/68 65/65/68

Max. external static pressure (EH/H/L) Pa 90/80/37 95/65/42 105/70/38 140/110/70 90/55/35

Sound pressure level (EH/H/L) dB(A)Heat reclaim mode 28/27/22 32/30/26 34/32/26 39/37.5/34 38.5/37/33Bypass mode 28/27.5/22.5 32/31/27 35/33/27.5 39.5/38/35 39/37.5/33.5

DimensionsHeight mm 270 270 270 388 388Width mm 599 804 904 884 1134Depth mm 882 882 962 1322 1322

Weight kg 29 37 43 71 83

Duct diameter mm 150 150 200 250 250

Filtration efficiency grade (EU3) % 82 82 82 82 82

Power supply V-ph-Hz 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50 220/240-1-50

Operating range °C -10 to 40 -10 to 40 -10 to 40 -10 to 40 -10 to 40

Relative humidity % 85% or less

L - LowH - HighEH - Extra high

Retail price

Indoor unit £ 920.- 1165.- 1490.- 2165.- 2480.-

Accessories

Model Reference Retail price £

RBC-VNC1/VNP1 Wall controllers to suit the above 440.-RBC-VNP1 PCB for the above (to fit wall controller and DI module) 130.-RBC-VNH1 Heater for VN-250/350 (1 x 1 kW heater diameter 150 mm) 325.-RBC-VNH2 Heater for VN-500 (2 x 1 kW heater diameter 200 mm) 325.-RBC-VNH3 Heater for VN-800/1000 (2 x 1 kW heater diameter 250 mm) 325.-

Air-to-Air Heat Exchangers

• Five models, air flow range 70 to 280 l/s

• Can be integrated into air conditioning systems,reduces size of overall system

• Fresh air ventilation

• Changes temperature and humidity of enteringfresh air

• Helps prevent sick building syndrome

• Reclaims 20-50% of the energy lost byventilation

• Improved energy efficiency

• Recovery of up to 75% heat from the outgoingair

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 51

Page 52: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

52

Outdoor Unit SM563AT-E SM803AT-E SM1103AT-E SM1403AT-E

Cooling Capacity (kW) kW 1.5-5.6 1.5-7.4 3.0-11.2 3.0-13.2Heating Capacity (kW) kW 1.5-6.3 1.5-9.0 3.0-13.0 3.0-16.0

HEX Air Volume m³/hr 780-1050 810-1230 1170-2010 1230-2100HEX Coil Volume cm³ 500-1450 600-1850 1000-3000 1250-3750HEX Coil Diameter mm/in 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)HEX Paths 4-6 6-8 6-10 8-12

EX. Piping limits m 5-30 5-30 5-50 5-50EX. Pipe Diameter mm 12.7/6.4 15.9/9.5 15.9/9.5 15.9/9.5

Replacement Technology YES YES YES YESOutdoor Unit Power Supply 1 phase 1 phase 1 phase 1 phase

Retail price

Outdoor Unit £ 835 1215 1540 1685Interface £ 440 440 440 440System Price £ 1275 1655 1980 2125

Outdoor Unit SM1603AT-E SM2244AT8-E SM2804AT8-E

Cooling Capacity (kW) kW 3.0-16.0 9.8-22.4 9.8-27.0Heating Capacity (kW) kW 3.0-16.0 9.8-25.0 9.8-31.5

HEX Air Volume (m3/hr) m³/hr 1260-2130 1170-2010 1230-2100HEX Coil Volume (cm3) cm³ 1450-4250 2000-6000 2550-7500HEX Coil Diameter (mm / in) mm/in 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)HEX Paths 8-12 10-12 10-12

EX. Piping limits (m) m 5-50 5-75 5-75EX. Pipe Diameter (mm) mm 15.9/9.5 19.1/12.7 19.1/12.7

Replacement Technology YES YES YESOutdoor Unit Power Supply 1 phase 3 phase 3 phase

Retail price

Outdoor Unit £ 2110 3000 3150Interface £ 440 440 440System Price £ 2550 3440 3590

Outdoor Unit SP564AT-E SP804AT-E SP1104AT-E SP1404AT-E

Cooling Capacity (kW) kW 1.2-5.6 1.9-8.0 2.6-12 2.6-14.0Heating Capacity (kW) kW 0.9-8.1 1.3-11.3 2.4-13 2.4-16.5

HEX Air Volume (m3/hr) m³/hr 780-1050 810-1230 1170-2010 1230-2100HEX Coil Volume (cm3) cm³ 500-1450 600-1850 1000-3000 1250-3750HEX Coil Diameter (mm / in) mm/in 9.52 (3/8) 9.52 (3/8) 9.52 (3/8) 9.52 (3/8)HEX Paths 4-6 6-8 6-10 8-12

EX. Piping limits (m) m 5-50 5-50 3-75 3-75EX. Pipe Diameter (mm) mm 12.7/6.4 15.9/9.5 15.9/9.5 15.9/9.5

Replacement Technology YES YES YES YESOutdoor Unit Power Supply 1 phase 1 phase 1 phase 1 phase

Retail price

Outdoor Unit £ 1015 1510 1900 2100Interface £ 440 440 440 440System Price £ 1455 1950 2340 2540

• Toshiba Twin Rotary Compressor Technology

• Outdoor unit 240V, 1 phase supply (2,3,4,5& 6HP), 400V, 3 phase supply (8 & 10HP)

• Suitable for R22 and R407c replacement

• High efficiency inverter compressor

• Light weight and easy to install

• No additional expansion valves or mechanical

equipment required

• Bespoke ‘Easy to Use’ Control set-up

NOTE: Minimum air on condition to the coil must be 18oC in heating mode.

Air Handling Unit Applications

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 52

Page 53: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

53

Part Number Description DI/SDI VRF VRF RAS Retail price

2-pipe 3-pipe £

Branch Kits

RBM-BY54E Y-joint 2-pipe < 6.4 HP ¸ 66.-

RBM-BY104E Y-joint 2-pipe < 6.4-14.2 HP ¸ 84.-

RBM-BY204E Y-joint 2-pipe < 14.2-25.2 HP ¸ 142.-

RBM-BY304E Y-joint 2-pipe 25.2 HP ¸ 186.-

RBM-BY54FE Y-joint 3-pipe < 6.4 HP ¸ 67.-

RBM-BY104FE Y-joint 3-pipe < 6.4-14.2 HP ¸ 92.-

RBM-BY204FE Y-joint 3-pipe < 14.2-25.2 HP ¸ 153.-

RBM-BY304FE Y-joint 3-pipe 25.2 HP ¸ 208.-

Header

RBM-HY1043E 4-way Header 2-pipe< 14.2 ¸ 128.-

RBM-HY2043E 4-way Header 2-pipe < 14.2-25.2 HP ¸ 140.-

RBM-HY1083E 8-way Heater 2-pipe < 14.2 ¸ 204.-

RBM-HY2083E 8-Way Header 2-pipe < 14.2-25.2 HP ¸ 224.-

RBM-HY1043FE 4-way Header 3-pipe < 14.2 ¸ 140.-

RBM-HY2043FE 4-way Header 3-pipe < 14.2-25.2 HP ¸ 195.-

RBM-HY1083FE 8-way Header 3-pipe < 14.2 ¸ 225.-

RBM-HY2083FE 8-way Header 3-pipe < 14.2-25.2 HP ¸ 235.-

T-Connector

RBM-BT13E T-Piece kit for 2-pipe S-MMS modular units ¸ 118.-

RBM-BT13FE T-Piece kit for 3-pipe S-HRM modular units ¸ 118.-

Twin Kits

RBC-TWP101E Large capacity DI twin kit ¸ 133.-

RBC-DTWP101E Large capacity DI double twin kit ¸ 181.-

RBC-TRP100E Triple kit (for DI units only) ¸ 159.-

Remote Controllers

RBC-AMT32E Wired remote controller (excl. Flexi unit) ¸ ¸ ¸ 52.-

RBC-AMS41E Wired remote controller CW 24/7 Day Timer ¸ ¸ ¸ 65.-

RBC-AS21E2 Simplified wired remote controller (excl. Flexi unit) for domestic and hotel application ¸ ¸ ¸ 60.-

RBC-AX22CE2 Wireless remote controller kit - for ceiling suspended units ¸ ¸ ¸ 160.-

TCB-AX21E2 Wireless remote controller kit - for ducted units ¸ ¸ ¸ 233.-

RBC-AX31U(W)-E Infrared controller - 4 series cassettes, Digital Inverter ¸ 142.-

TCB-EXS21TLE 7-day weekly/schedule timer complete with day omit ¸ ¸ ¸ 220.-

Central Remote Control

TCB-SC642TLE2 64-zone central remote controller ¸* ¸ ¸ 600.-

TCB-CC163TLE2 16-zone Remote on/off controller ¸ ¸ ¸ 645.-

Touch Screen Control

BMS-TP0641ACE Enables full control of up to 64 indoor units ¸* ¸ ¸ 5000.-

BMS-TP0641PWE Enables full control of up to 64 indoor units with electric billing ¸* ¸ ¸ 5500.-

BMS-TP5121ACE Enables full control of up to 512 indoor units ¸* ¸ ¸ 5750.-

BMS-TP5121PWE Enables full control of up to 512 indoor units with electric billing ¸* ¸ ¸ 6700.-

BMS-IFLSV3E TCS-Net relay interface ¸* ¸ ¸ 610.-

BMS-IFWH4E2 Energy monitoring relay interface ¸* ¸ ¸ 680.-

BMS-IFDD02E2 Digital I/O relay interface ¸* ¸ ¸ 680.-

Outdoor Unit Option PCBs

TCB-PCDM2E Power peak-cut control board ¸ ¸ 66.-

TCB-PCIN2E Error output control board ¸ ¸ 68.-

TCB-PCMO2E External master ON/OFF control board ¸ ¸ 50.-

TCB-PCOS1E2 Application Control Kit ¸ 130.-

Controls and accessoriesAir Handling Unit Applications

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 53

Page 54: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

54

Controls and Accessories

Part Number Description DI/SDI VRF VRF RAS Retail price

2-pipe 3-pipe £

Network Adapters

TCB-PCNT20E Network adapter ¸ 140.-

TCB-PCNT30TLE2 “1:1 model” connection interface ¸ 65.-

TCB-PX30MUE Terminal box for TCB-PCNT30TLE2 ¸** 51.-

Compliant Manager

BMS-CM1280FTLE High-spec Compliant Manager ¸ ¸ ¸ 2178.-

BMS-CM1280TLE Standard Compliant Manager ¸ ¸ ¸ 1380.-

BACnet

BMS-STBN08E BACnet Software ¸* ¸ ¸ 3350.-

BMS-LSV6E Intelligent Server ¸* ¸ ¸ 2950.-

BMS-IFLSVE3 TCS-Net Relay Interface ¸* ¸ ¸ 610.-

Lonworks

TCB-IFLN640TLE2 LONworks Gateway ¸* ¸ ¸ 1070.-

RBC-LG1-PE AI LONworks Gateway ¸* ¸* ¸* 635.-

Flow Selector Extension Cable

RBC-FSEX15 15 m Extension Cable for Flow Selector Boxes ¸ 94.-

RAS & Daiseikai Accessories

RBC-IT3-PE Timer Interface for Super Daiseikai units ¸ 98.-

RBC-SH-A1LE2 Wired Remote for RAS Ducted units ¸ 290.-

VN Unit Control

RBC-VNC1/VNP1 Wall Controller/PCB for VN units‡ 440.-

RBC-VNH1 Heater for VN-250/350‡ 325.-

RBC-VNH2 Heater for VN-500‡ 325.-

RBC-VNH3 Heater for VN-800/1K‡ 325.-

RBC-VNP1 PCB for VN units‡ 130.-

RBC-VNT1 VN External Thermostat for use with RBC-VNP1 and RBC-DI1‡ 110.-

Windows Control

RBC-WP1-PE Windows Control Package ¸* ¸ ¸ 3660.-

RBC-EM1-PE Energy Monitoring Kit (used with Windows control package) ¸* ¸ ¸ 1200.-

RBC-IK1-PE Internet Kit (used with Windows control package) ¸* ¸ ¸ 1587.-

RBC-DI1-PE Digital Input/Output module (Di160) ¸* ¸ ¸ 720.-

Indoor Unit Option Leads/PCBs

RBC-SMCN61 Interface lead for ON/OFF and unit remote controller lock ¸ ¸ ¸ 8.-

RBC-SMCN61L Interface lead for remote controller lock ¸ ¸ ¸ 8.-

RBC-SMIM2 Indicator module for unit in heating, cooling or fan only modes ¸ ¸ ¸ 70.-

RBC-SMIM3 Indicator module for lock-out fault and unit run ¸ ¸ ¸ 60.-

RBC-SMIM4 Indicator module for lock-out fault, unit run and remote on/off ¸ ¸ ¸ 67.-

RBC-SMF1 Enables control of external fans ¸ ¸ ¸ 40.-

RBC-IT4-PE External interface to allow for 240 volt switching of equipment ¸ ¸ ¸ 77.-

RBC-SMT1 Timer Interface Lead ¸*** ¸*** ¸*** 15.-

TCB-IFCB-4E2 Remote location ON/OFF control box ¸ ¸ 200.-

Remote Sensor

TCB-TC21LE2 Remote temperature sensor ¸ ¸ ¸ 56.-

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 54

Page 55: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

55

Part Number Description DI/SDI VRF VRF RAS Retail price

2-pipe 3-pipe £

Other Accessories

RBC-IT2-PE Timer Interface for all R407C equipment 57.-

LA5 Low Ambient Kit ¸† 110.-

TCB-DP22CE2 Drain Pump for DI Ceiling Suspended Units ¸ ¸ ¸ 165.-

TCB-KP12CE2 Ceiling Unit Elbow Piping Kit (1.7/2 HP) ¸**** ¸**** ¸**** 52.-

TCB-KP22CE2 Ceiling Unit Elbow Piping Kit (3/4/5 HP) ¸**** ¸**** ¸**** 63.-

RBC-FDP3-PE Monitoring and control interface for VRF and DI/SDI ¸ ¸ ¸ 320.-

Estia Accessories

TCB-PCMO3E External input PCB, for Estia 52.-

TCB-PCIN3E Run/fault output PCB for Estia 72.-

Ancillary Products

RBC-AHU1 Air handling unit interface 440.-

RBC-RD3 Refrigerant leak detection sensor and interface (one per zone) 300.-

Proprietary Coil Anti-Corrosion Coating

CACC-SF Single-fan unit coil anti-corrosion coating ¸ ¸ ¸ ¸ 333.-

CACC-DF Double-fan unit coil anti-corrosion coating ¸ ¸ ¸ ¸ 427.-

CACC-VRF VRF module unit coil anti-corrosion coating ¸ ¸ ¸ ¸ 823.-

VRF Flat Pack Service

RBC-VRF-FP†† Separation of a VRF outdoor unit into its component parts ¸ ¸ 1650.-

* For this control option a network adapter is required at the indoor unit.** This terminal box is used with all four-way blow and 600 x 600 mm DI/SDI cassette units.*** This lead plugs into the standard remote control (RBC-AMT32E and central controllers (TCB-SC642TLE2, TCB-CC642TLE2).**** The elbow piping kit allows the refrigeration circuit connections to be routed to allow fitting of the pump.† Early RAS/RAV R-22 units.†† This price is for separating a single VRF outdoor module to facilitate access to final on-site location where accessibility is limited. It is the installation contractor’s

responsibility to re-build the equipment. Included in this price we offer the assistance of a technical adviser during the re-build and/or commissioning of the equipment.This will be limited to one day on-site.

‡ For use with the air-to-air heat exchanger.

Controls and accessories

The information shown in this price list is based on the following data:

Nominal capacities are based on Eurovent conditions:

Cooling: indoor air temperature 27°C db/19°C wb, outdoor air temperature 35°C db/24°C wb

Heating: indoor air temperature 20°C db, outdoor air temperature 7°C db

UK capacities are based on the following conditions: Cooling: indoor air temperature 22°C db, outdoor air temperature 28°C db, 50% rh, 5 m pipe run and high fan speed

Heating: indoor air temperature 21°C db, outdoor air temperature -4°C db, 100% rh, 5 m pipe run and high fan speed.

Values are based on the maximum compressor output.

The sound pressure levels are based on:

Outdoor units at 1 m distance, indoor units at 1.5 m distance

The annual power consumption is based on 500 operating hours.

The maximum running current is based on 240 V in the cooling mode.

Controls and Accessories

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 55

Page 56: Price List - Air Conditioning Solutions - Heronhill Air ...€¢ Easy to use remote control with extra-large display 4 Indoor unit RAS-107SKV-E3 RAS-137SKV-E3 RAS-167SKV-E3 Outdoor

The manufactures reserves the right to change the product specifications and images without notice. Printed in the Netherlands on chlorine-free paperRef No. PLE6-03.09

Toshiba products are supplied by:

950351_Pricelist_2010_155450_PrLst0708_001-048 22/03/2010 10:03 Page 56

duncan.talbot
Typewritten Text
www.heronhill.co.uk Tel: (01823) 665660 Fax: (01823) 665807
duncan.talbot
Typewritten Text
duncan.talbot
Typewritten Text
Heronhill Air Conditioning Ltd
duncan.talbot
Typewritten Text
duncan.talbot
Typewritten Text
duncan.talbot
Typewritten Text
Summerfield Way, Chelston Business Park, Wellington, Somerset. TA21 9JE
duncan.talbot
Typewritten Text
duncan.talbot
Typewritten Text
duncan.talbot
Typewritten Text
duncan.talbot
Typewritten Text

Recommended