CE 0694 TA99E009.A0704 Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH Setting instruction Manual for boilers with SM 30001 Printed Circuit board mod. RBC 24 (open chamber) RBS 24 (room sealed)
Transcript
Page 1: Printed Circuit board - Portsdean Heating Files... · 2012-04-16 · sm 30001 printed circuit board cod. 76666la m9 m10 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 functions setting 1-a standard

CE 0694 TA99E009.A0704 Technical Specification RADIANT BRUCIATORI S.p.A. Montelabbate (PU) ITALY ENGLISH

Setting instruction Manual for boilers with

SM 30001 Printed Circuit board

mod. RBC 24 (open chamber) RBS 24 (room sealed)

Page 2: Printed Circuit board - Portsdean Heating Files... · 2012-04-16 · sm 30001 printed circuit board cod. 76666la m9 m10 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 functions setting 1-a standard
Page 3: Printed Circuit board - Portsdean Heating Files... · 2012-04-16 · sm 30001 printed circuit board cod. 76666la m9 m10 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 functions setting 1-a standard

INDEX

CONTROL PANEL page 1

SM 30001 ELECTRONIC PRINTED CIRCUIT BOARD:

FUNCTIONS SETTING PROCEDURE page 2

BOILER TYPE SETTING PROCEDURE page 2

MAXIMUM GAS PRESSURE SETTING page 4

MINIMUM GAS PRESSURE SETTING page 4

HEATING OUTPUT SETTING page 4

CENTRAL HEATING / D.H.W. MODE OPERATION page 4

RESET PROCEDURE page 4

TECHNICAL SPECIFICATIONS page 5

GAS DATA TABLE page 6

GAS PRESSURE SETTING page 6

HEATING OUTPUT PRESSURE DIAGRAM page 6

ELECTRICAL WIRING DIAGRAM page 7

P.C.B. SM 30001 – boiler settings

Page 4: Printed Circuit board - Portsdean Heating Files... · 2012-04-16 · sm 30001 printed circuit board cod. 76666la m9 m10 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 functions setting 1-a standard

CONTROL PANEL

6 1 ON / OFF POWER BUTTON STABLE LIGHT: 50°C TEMPERATURE FLASHING LIGHT: FLUE SAFETY THERMOSTAT LOCK-

OUT (for open chamber model only)

2

7 HEATING TEMPERATURE ADJUSTMENT KNOB STABLE LIGHT: 60°C TEMPERATURE

3

FLASHING LIGHT: FLAME LOCK-OUT

8

DOMESTIC HOT WATER TEMPERATURE ADJUSTMENT KNOB STABLE LIGHT: 70°C TEMPERATURE

4

FLASHING LIGHT: HIGH LIMIT THERMOSTAT LOCK-OUT

9

STABLE LIGHT: POWER ON FLASHING LIGHT: FLAME ON

STABLE LIGHT: 80°C TEMPERATURE

5

FLASHING LIGHT: D. HOT WATER / HEATING SENSOR FAILURE

STABLE LIGHT: 40°C TEMPERATURE FLASHING LIGHT: WATER DEFICIENCY LIGHT OFF: WATER PRESSURE LEVEL 1 bar

P.C.B. SM 30001 – boiler settings 1

Page 5: Printed Circuit board - Portsdean Heating Files... · 2012-04-16 · sm 30001 printed circuit board cod. 76666la m9 m10 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 functions setting 1-a standard

SM 30001 PRINTED CIRCUIT BOARD cod. 76666LA

M10M9

M2

M1

M11

M12

M13 M3

M8 M7

M5

M4

M6

FUNCTIONS SETTING

1-A STANDARD 30-80°C - OFF

REDUCED 25-40°C - ON BOILER TYPE SETTING

IN

6-F OFF

ON

NOT APPLICABLE DUAL CIRCUIT EXCHANGER type

5-E OFF

ON

TEM4-D 64-65°C - OFF

58-61°C - ON

HOT WATER PERATURE SETTING

Func

3-C DISCONNECTED - OFF

ACTIVE - ONWATER-HAMMER Prevention

tion

2-B ACTIVE - OFF

DISCONNECTED - ON SHORT-CYCLING Function

TIMER (3 min.)

HEATING TEMPERATURE SETTING

6-F OFF

ON

P.C.B. SM 30001 – boiler settings 2

NSTANTANEOUS TYPE BOILER OT APPLICABLE

N L

ATURAL GAS OPERATION.P.G. OPERATION

Page 6: Printed Circuit board - Portsdean Heating Files... · 2012-04-16 · sm 30001 printed circuit board cod. 76666la m9 m10 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 functions setting 1-a standard

8 9 10 11 12 13

Fig. 2

5

F

CONTROL PANEL

GAS VALVE NORDGAS

NV0111122901

1 2 3 4 CONTROLS (fig. 1-2) 1. “MAXR” MAXIMUM HEATING POTENTIOMETER 2. “MIN” MINIMUM GAS POTENTIOMETER 3. “RLA” STARTING STEP POTENTIOMETER 4. “SPAZ” CHIMNEY-SWEEPER FUNCTION 5. GAS PRESSURE POINT - OUTLET 6. GAS ADJUSTMENT SCREW 7. GAS PRESSURE POINT – INLET 8. STABLE LIGHT: POWER ON

FLASHING LIGHT: FLAME ON 9. STABLE LIGHT: 40°C TEMPERATURE

FLASHING LIGHT: WATER DEFICIENCY LIGHT OFF: WATER PRESSURE LEVEL 1.2 bar

10. STABLE LIGHT: 50°C TEMPERATURE FLASHING LIGHT: FLUE SAFETY THERMOSTAL LOCK-OUT (for open chamber model only)

11. STABLE LIGHT: 60°C TEMPERATURE FLASHING LIGHT: FLAME LOCK-OUT

12. STABLE LIGHT: 70°C TEMPERATURE FLASHING LIGHT: HIGH LIMIT THERMOSTAT LOCK-OUT

13. STABLE LIGHT: 80°C TEMPERATURE FLASHING LIGHT: D. HOT WATER / HEATING SENSOR FAILURE

P.C.B. SM 30001 – boiler settings 3

6

7

ig. 1

Page 7: Printed Circuit board - Portsdean Heating Files... · 2012-04-16 · sm 30001 printed circuit board cod. 76666la m9 m10 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 functions setting 1-a standard

MAXIMUM GAS PRESSURE SETTING • Unscrew 5 gas pressure point screw (fig. 1) on the gas valve and insert a manometer;

• Turn heating and domestic hot water setting knobs to the maximum and remove the 2 knob by

extracting them with a pliers:

• Use a Ø2.5 ÷ 3 mm cross-type screwdriver and turn “maxR” 1 potentiometer (fig. 2) clockwise to the

maximum;

• Switch the boiler ON;

• Keep 4 potentiometer (chimney sweeper function) (fig. 2) pressed for 10 seconds;

• The manometer will show the maximum gas pressure value; if that value is different than the one

stated on the Data Plate (see Gas pressure adjustment table pag. 6), modify it as follows: turn the 6

gas adjustment screw (fig. 1) clockwise to increase gas pressure and counter clockwise to decrease

gas pressure to reach the data Plate pressure value.

MINIMUM GAS PRESSURE SETTING

• Turn “maxR” 1 potentiometer (fig. 2) counter clockwise to the minimum;

• Turn 2 potentiometer (minimum gas) (fig. 2) clockwise to increase or counter clockwise to decrease

the gas pressure;

• Turn 3 potentiometer (starting step) (fig. 2) to the middle position of its full setting;

HEATING OUTPUT SETTING

• Turn the “maxR” 1 potentiometer (maximum heating) (fig. 2) clockwise and set the pressure value

according to the system requirement. (see Heating Output Pressure Diagram at page 6);

• Remove the silicon pipe from the pressure point 5 (fig. 1);

• Close tightly the pressure point screw and make sure there are no gas leaks;

• Fit the 2 plastic knobs back to position;

• Put ON/OFF button in OFF and than ON position.

CENTRAL HEATING / DOMESTIC HOT WATER MODE OPERATION If the boiler has to operate on both central heating and domestic hot water mode, do NOT set the central

heating and d.h. water knobs to the minimum (zero);

• Set the domestic hot water knob to ‘0’ (zero) for a HEATING ONLY mode;

• Set the central heating knob to ‘0’ (zero) for a WATER ONLY mode;

RESET PROCEDURE In case of a ‘Flame Lock-out’ (indicator 11 or 12 fig. 2 page 3), reset the boiler by putting the ON/OFF

button in OFF and than ON position.

P.C.B. SM 30001 – boiler settings 4

Page 8: Printed Circuit board - Portsdean Heating Files... · 2012-04-16 · sm 30001 printed circuit board cod. 76666la m9 m10 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 functions setting 1-a standard

TECHNICAL SPECIFICATION

New generation printed circuit board with easy settings of boiler parameters.

Special features:

Main functions / features Chimney-sweeper function (15 minutes)

Pump over-run function (2 minutes)

Pump inactivity protection system

Water-Hammer prevention function

Suitable for outside temperature sensor connection

Suitable for remote control system connection

Self-diagnostic

Continuous electronic modulation for central heating and domestic hot water

Adjustable heating output

Adjustable starting step

Exclusively for technicians settings Standard / reduced heating temperature from 30 to 80 °C / 25 to 40°C

• Water-Hammer prevention function • Short cycling function-3 minutes stand-by, heating circuit • Maximum gas pressure setting

• Minimum gas pressure setting

• Heating output setting

User Settings

• On / Off operation

• Heating temperature adjustment from 30 to 80 °C / 25 to 45°C • Domestic Hot Water adjustment from 35 to 65 °C

• Mode selection knob: summer/winter/heating only

• Lock-out

• Normal water pressure • Water deficiency safety switch

• Temperature indicator

P.C.B. SM 30001 – boiler settings 5

Page 9: Printed Circuit board - Portsdean Heating Files... · 2012-04-16 · sm 30001 printed circuit board cod. 76666la m9 m10 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 functions setting 1-a standard

GAS DATA TABLE

model: RBC 24 RBS 24 NATURAL GAS G 20

LIQUID BUTAN GAS G 30

LIQUID PROPANE GAS G 31

Lower Wobbe index (15°C; 1013 mbar) MJ/Nm3 45.67 80.58 70.69

Rated feed pressure mbar 20 30 37 Minimum feed pressure mbar 17 20 25 Main burner: 12 Jets - Ø jet mm 1.30 0.77 0.77 Consuption (15°C; 1013 mbar) m3/h 2.71 - - Consuption (15°C; 1013 mbar) kg/h - 2.019 1.99

GAS PRESSURE SETTING

HEATING OUTPUT MAXIMUM PRESSURE DIAGRAM

(G20 Natural Gas - G30/31 L.P.G.)

L.P.G.

NATURAL GAS

0

2

4

6

8

10

12

14

16

18

20

22

24

26

28

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33

Gas pressure in mbar

Hea

ting

Out

put i

n kW

models Natural Gas G 20 G.P.L. G 30/31 min. max. min. max RBC 24 mbar 2.2 10.8 5 30 RBS 24 mbar 1.5 10.4 5 30

mod. RBC 24 (open chamber) RBS 24 (room sealed)

P.C.B. SM 30001 – boiler settings 6

Page 10: Printed Circuit board - Portsdean Heating Files... · 2012-04-16 · sm 30001 printed circuit board cod. 76666la m9 m10 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 functions setting 1-a standard

WIRING DIAGRAM

brow

n

brow

n

light

-blu

e

light

-blu

e

NL

light

-blu

e

brow

n

blac

k

red/

blac

k

blac

k

whi

te/b

lack

blac

k

blac

k

blue

red

whi

te

gree

n

light

-blu

e

blac

k

grey

brow

n

light

-blu

e

brow

n

- TRANSFORMERTR

L

TF

TSM.F.TA

C

N

SSSR

IGPAC

VGEAER

EVPA

- CIRCULATION PUMP

- SAFETY FLUE THERMOSTAT

- SAFETY THERMOSTAT- ELECTRONIC FLOWSWITCH- ROOM THERMOSTAT

- LINE

- MAIN SWITCH

- NEUTRAL

- HEATING SENSOR- D.H. WATER SENSOR

KEY

- WATER PRESSURE SWITCH

- GAS VALVE

- IONISATION ELECTRODE

- FAN- AIR PRESSURE SWITCH

Optional

TERMINAL

BLOCK

230V50 Hz

L NTA SE

- IGNITION ELECTRODE

light

-blu

e

brow

n

P52 T

M8

TF

VG

M6

M4

M5

M7M8

M3M13

M12

M11

M1

M2

M9 M10

EA TR

+ -

5251

ER

18

M13M3

230V50 Hz

18

PRINTED CIRCUIT BOARD SM30001 (COD. 76666LA)

NL

M21 2 3 4

oran

ge

oran

ge

IG

PA

M8T52 P

brow

n

light

-blu

e

C

5

M1286 7 9

EV

1918

M11

SS

45 4846 47 49 50

SR MF

M5

M75351 52 54

oran

ge

blac

k

blac

k

oran

ge

231 4

OP

VG

TS

M945 4846 47 49 50

1,5barPAC

1918

M10

P.C.B. SM 30001 – boiler settings 7

Page 11: Printed Circuit board - Portsdean Heating Files... · 2012-04-16 · sm 30001 printed circuit board cod. 76666la m9 m10 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 functions setting 1-a standard
Page 12: Printed Circuit board - Portsdean Heating Files... · 2012-04-16 · sm 30001 printed circuit board cod. 76666la m9 m10 m2 m1 m11 m12 m13 m3 m8 m7 m5 m4 m6 functions setting 1-a standard

RADIANT BRUCIATORI s.p.a. Via Pantanelli, 164/166 - 61025 Loc. Montelabbate (PU) Tel. +39 0721 9079.1 • fax. +39 0721 9079279 e-mail: tecnico@radiant • Internet: http://www.radiant.it

ALL DESCRIPTIONS AND ILLUSTRATIONS CONTAINED IN THIS LEAFLET HAVE BEEN CAREFULLY PREPARED BUT WE RESERVE THE RIGHT TO MAKE CHANGES AND IMPROVEMENTS IN OUR PRODUCTS WHITCH MAY AFFECT THE ACCURANCY OF THE INFORMATION CONTAINED IN THIS LEAFLET. E + OE ALL RIGHTS RESERVED. NO PART OF THIS DOCUMENT MAY BE REPRODUCED, SAVED IN STORAGE SYSTEMS OR TRANSMITTED IN ANY FORM OR BY ANY MEANS, WHETHER ELECTRONIC, MECHANICAL, PHOTOCOPYING, RECORDING OR OTHERS, WITHOUT THE MANUFACTURER'S PRIOR AUTHORISATION IN WRITING.

TA99E009.A0704


Recommended