Page 1WWW.JADEMAR.COM
Miami, FL USA - [email protected]: 305.640.0465 - F: 305.640.0468
Information contained herein is subject to change without notice.
Values are nominal. All values conform to DLC tolerances.
Revised 05/2019
10.24”
18.03”
4.0
2”
SPECIFICATION SUBMITTAL DETAILProject Name/Type: Date:
Catalog/Part #:
Ÿ Optimal heat dissipation design. Integral secondary heat sink to optimize thermal transfer and maximize performance and life of the LED.
Ÿ Universal voltage 120-277VAC Ÿ Dimming: 0-10VŸ SSC LED and BOB Technology (Driverless)Ÿ Type III optics (Type II, V optional)Ÿ Grey nish (bronze, black optional)Ÿ LED Module has inherent 10 KV SPD (Total Protection
20KV). For 30KV protection request optional 20KV replaceable SPD
Ÿ 5pin and 7pin photocell receptables are optionalŸ Lighting shield optional Ÿ Adjustable Output Unit OptionalŸ Housing made of rust resistant Die-Cast Aluminum
Alloy.
Ÿ Dust and waterproof Ÿ 100,000 hrs. at 70% lumen maintenance rated lifeŸ Compliance with UL, DLC, IDA, 3G vibration rating
(ANSI C136), Anti-salt fog (ASTM B117), FCC B15, Ip65, IEC-EN62471, CE-IEC60598, RoHs
Ÿ 10 year warranty
Features
PRL-LED SERIESLED ROADWAY LIGHT 50W & 100W
Data Table
Applications
Ÿ RoadwaysŸ Residential StreetsŸ Parking Areas Ÿ Storage AreasŸ Public Parks
Dimensions
Model # PRL50LEDMV-40T3PC PRL100LEDMV-40T3PC
Housing Color: Gray Gray
Power Consumption 50W±10% 100W±10%
Nominal Watts 50W 100W
Voltage 120-277V 120-277V
Driver JG DOB JG DOB
Driver Current 0.15A 0.15A
Power Factor ≥0.99 ≥0.99
LED Chips SSC5050 LED SSC5050 LED
Initial lumens 6,203 lms 11,477 lms
Efficiency 124 lpw 115 lpw
Frequency 50/60Hz 50/60Hz
CCT 4000K 4000K
CRI >70 >70
Operating Temp -40°C ~ +50°C -40°C ~ +50°C
THD: <15% <15%
BUG Rating: B1U0G1 B2U0G2
Surge Suppression Rating: 10KV 10KV
Listings/Ratings
UL, DLC, IDA, 3G (ANSI
C136)(ASTM B117), FCC
B15, , IEC-EN62471, CE-
IEC60598, RoHs
UL, DLC, IDA, 3G (ANSI
C136)(ASTM B117), FCC
B15, , IEC-EN62471, CE-
IEC60598, RoHs
Life 100,000 Hrs. 100,000 Hrs.
LM70/80 Life 132,000 Hrs. 113,000 Hrs.
Warranty 10 Yrs. 10 Yrs.
Beam Angle 120° 120°
Optics Type III Type III
Mounting Type: Pole Mount Pole Mount
Size: N/A N/A
Style: Roadway/Street Light Roadway/Street Light
Product Dimensions 18.03" x 10.24" x 4.02" 18.03" x 10.24" x 4.02"
Carton Dimensions 20.5" x 12" x 6.5" 20.5" x 12" x 6.5"
Units/Ctn 1 pc. 1 pc.
Weight/Ctn 6.2 lbs. 6.2 lbs.
Page 2WWW.JADEMAR.COM
Miami, FL USA - [email protected]: 305.640.0465 - F: 305.640.0468
Information contained herein is subject to change without notice.
Values are nominal. All values conform to DLC tolerances.
Revised 05/2019
SPECIFICATION SUBMITTAL DETAILProject Name/Type: Date:
Catalog/Part #:Ÿ SSC LED and BOB Technology (Driverless)
Ÿ Lighting shield optional
Ÿ Compliance with UL, DLC, IDA, 3G vibration rating (ANSI C136), Anti-salt fog (ASTM B117), FCC B15, Ip65, IEC-EN62471, CE-IEC60598, RoHs
Ÿ Type III optics (Type II, V optional)
Ÿ Housing made of rust resistant Die-Cast Aluminum Alloy.
Ÿ Dimming: 0-10V
Ÿ Adjustable Output Unit Optional
Ÿ Dust and waterproof
Ÿ 5pin and 7pin photocell receptables are optional
Ÿ LED Module has inherent 10 KV SPD (Total Protection 20KV). For 30KV protection request optional 20KV replaceable SPD
Ÿ Optimal heat dissipation design. Integral secondary heat sink to optimize thermal transfer and maximize performance and life of the LED.
Ÿ Grey nish (bronze, black optional)
Ÿ Universal voltage 120-277VAC
Ÿ 100,000 hrs. at 70% lumen maintenance rated life
Ÿ 10 year warranty
Features
PRL-LED SERIESLED ROADWAY LIGHT 150W & 200W
Data Table
Applications
Ÿ Public Parks
Ÿ Parking Areas Ÿ Residential Streets
Ÿ Storage Areas
Ÿ Roadways
Dimensions
2EPA: 0.08m2
(0.8 ft)Weight: 6.5 kgs
(14.5 lbs)572mm(22.5")
13
4m
m(5
.3")
330mm(13.0")
Model # PRL150LEDMV-40T3PC PRL200LEDMV-40T3PC
Housing Color: Gray Gray
Power Consumption 150W±10% 200W±10%
Nominal Watts 150W 200W
Voltage 120-277V 120-277V
Driver JG DOB JG DOB
Driver Current 0.15A 0.15A
Power Factor ≥0.99 ≥0.99
LED Chips SSC5050 LED SSC5050 LED
Initial lumens 18298 lms 22,316 lms
Efficiency 122 lpw 112 lpw
Frequency 50/60Hz 50/60Hz
CCT 4000K 4000K
CRI >70 >70
Operating Temp '-40°C ~ +50°C '-40°C ~ +50°C
THD: <15% <15%
BUG Rating: B1U0G1 B1U0G1
Surge Suppression Rating: 10KV 10KV
Listings/Ratings
UL, DLC, IDA, 3G (ANSI
C136)(ASTM B117), FCC
B15, , IEC-EN62471, CE-
IEC60598, RoHs
UL, DLC, IDA, 3G (ANSI
C136)(ASTM B117), FCC
B15, , IEC-EN62471, CE-
IEC60598, RoHs
Life 100,000 Hrs. 100,000 Hrs.
LM70/80 Life 132,000 Hrs. 132,000 Hrs.
Warranty 10 Yrs. 10 Yrs.
Beam Angle 120° 120°
Optics Type III Type III
Mounting Type: Pole Mount Pole Mount
Size: N/A N/A
Style: Roadway/Street Light Roadway/Street Light
Product Dimensions 22.5" x 13.0" x 5.3" 22.5" x 13.0" x 5.3"
Carton Dimensions 20.5" x 12" x 6.5" 20.5" x 12" x 6.5"
Units/Ctn 1 pc. 1 pc.
Weight/Ctn 14.5 lbs. 14.5 lbs.
Page 3WWW.JADEMAR.COM
Miami, FL USA - [email protected]: 305.640.0465 - F: 305.640.0468
Information contained herein is subject to change without notice.
Values are nominal. All values conform to DLC tolerances.
Revised 05/2019
Installation Instructions
STEP 2: Open the power door. Power door will securely hang. See Figure 2.
STEP 3: Slide xture on to the pole through opening on the rear of housing and through splash guard. See Figure 3.
STEP 4: To level xture, use bubble level located inside housing. Adjust leveling of xture from side to side. To level from front to back, slide pole to different step in upper housing. Each step changes the angle in 2.5° degree increments. See Figure 3.
step marked “+5” provides maximum tilt.
STEP 6: Reference Electrical Connections section for completing electrical connections. See Figure 4.
Tilt: Stopping at the step marked “0” provides no tilt. Stopping at the
IMPORTANT: DO NOT exceed these torque levels on the mount bolts. Exceeding recommended torque value resulting in excessive deformation of mounting bracket will causes tripping of mount hardware which could lead to an unsafe mounting condition.
STEP 8: If luminaire is furnished with photo control receptacle, install the photo control or shorting. See Figure 6.
STEP 5: Once desired position is achieved, tighten mounting bolts to the appropriate torque values specied in TORQUE VALUES table to the left.
STEP 1: Unfasten the stainless steel latches. See Figure 1.
STEP 7: Close the housing cover and fasten the two stainless steel latches. See Figure 5.
incidental material.
consult a qualied electrician.
3. If NEMA photo control is installed refer to NEMA
2. This luminaire must be installed in accordance
receptacle section for instructions.
4. Verify the availability of necessary tools and
with the NEC or your local electrical code. If you are not familiar with these colors and requirements,
power supply before installation or servicing. 1. To reduce the risk of electrical shock, turn off the
Caution: When using electrical equipment, basic safety precautions should always be followed including the following. Read and follow all safety instruction carefully.