Process Instrumentation
Product Guide
Registered Quality System to ISO 9001:2000
is on your side. We understand the demanding requirements of
the process instrumentation industry and the harsh environments that
our products must often operate in. We’re committed to providing you with products you
can depend on day in and day out, year after year. We design, develop and manufacture
the highest quality, most reliable electronic and electromechanical level, pressure,
temperature and flow instruments available.
For more than 60 years, our watchwords - Doing it right every time – have earned SOR its
reputation for excellence by maintaining our commitment to the fundamentals of quality,
service and delivery.
We provide dynamic application support and unparalleled customer service through a
network of global offices staffed with well-trained and knowledgeable representatives. They
are committed to delivering the best products on time, when and where you need them,
anywhere in the world.
Our complete product line of instruments can help solve your application challenges.
While this Product Guide will help you make your initial instrumentation choices, our
representatives and service support staff can truly make the difference.
SOR capabilities extend beyond the manufacture and service of reliable instrumentation.
We also stand ready to help your company with problem-solving custom manufacturing,
OEM manufacturing and marketing expertise. We’re in this together. We’re on your side.
SOR is ready to help you from our headquarters in Lenexa, Kansas, or from right in your
own back yard – wherever that may be.
Phone: 913-888-2630
Toll Free: 800-676-6794
Fax: 913-888-0767
SOR®
Pre
ssu
re
Flow
Tem
pera
ture
Level
Design and specifications are subject to change without notice.
For the latest revisions, visit www.sorinc.com.
1
Table of Contents
Product Applications ............................................................. 2
Level Switches .......................................................................... 4
Level Transmitters ................................................................... 6
Pressure Switches ................................................................. 7
Pressure Transmitters .......................................................... 9
Differential Pressure Switches ...................................... 10
Flow Switches ........................................................................ 12
Temperature Switches ...................................................... 13
Approval Agencies .............................................................. 14
Hazardous Area Classification ..................................... 14
Environmental Protection ................................................ 14
Classifications
Outside North America ..................................... 15
Inside North America ......................................... 15
Other Capabilities and Services
Chemical Seals ...................................................... 16
Wireless ....................................................................... 16
Custom Manufacturing
Custom Products ................................. 16
Nuclear Qualified Products ............. 17
Marketing Communications ........................... 17
We Deliver Quality on time
Level Switches FlangedChamber ÒÒÒSealedChamber ÒÒTop-MountedDisplacer ÒÒÒTop-MountedFloat ÒÒÒSideMounted ÒÒÒÒSteamTrap ÒÒÒOEMLevel ÒÒÒSingle-PointUltrasonic ÒÒÒÒSingle-PointUltrasonic ÒÒÒÒwithSelfTestDual-PointUltrasonic ÒÒÒÒwithSelfTestSingle-PointRF ÒÒÒSingle-PointRFwith ÒÒÒSelfTestMultipointRF ÒÒÒ
Level TransmittersUltrasonic ÒÒÒÒSubmersibleHydrostaticPressure ÒÒÒ
RF ÒÒÒ
Pressure SwitchesWeatherproof ÒÒÒ(Pressure/Vacuum/Compound) Weatherproof TerminalBlockConnections ÒÒ(Pressure/Vacuum/Compound)
ExplosionProof ÒÒÒ(Pressure/Vacuum/Compound)
ExplosionProof UL/CSA/ATEX ÒÒÒ(Pressure/Vacuum/Compound)
BigHermetExplosionProof,HermeticallySealed
ÒÒÒ
(Pressure/Vacuum/Compound)
2
Oil & Gas • Wellhead pressure
• Flow line monitoring
• Separator levels
• Compressor
pressure monitoring
• Sump control
Petrochemical • Catalytic cracker
• Distillation
• Fractionation
• Hydrotreater/Reformer
• Coker
• Flare knockout tank
• Sump control
Power • Fuel storage and handling
• Steam turbine drip legs
• Hotwell condenser
• Feed water heaters
• Demineralization
• Ash precipitator/scrubber
• Steam drum level
• Sump control
Chemical & Other • Storage and batch tank level
• High level alarm
safety shutdown
• Solvent extraction
• Rupture disc integrity
• Filter integrity
• Water/wastewater treatment
• Pulp processing
• Rotating equipment lube systems
• Sump control
Nuclear Qualified
Ge
Ne
Ra
L a
PP
LIC
aTIO
NS
P r o d u c t A P P l i c At i o n sN
uclearQualified
Chem
ical&Other
Power
Petrochemical
Oil&G
as
Mini-HermetExplosionProof,HermeticallySealed ÒÒÒ(Pressure/Vacuum/Compound)
DualHi-LoWeatherproof ÒÒDualHi-Lo ExplosionProof Ò Ò Ò(Pressure/Vacuum/Compound)
Omni-Weatherproof Ò(Pressure)
SubMini-HermetExplosionProof,HermeticallySealed ÒÒÒ(Pressure)
Pressure TransmittersElectronicPressureInstrumentÒÒÒÒWeatherproof
ÒÒFixedRangeImmersible
ÒÒFixedRangeMini-HermetExplosionProof, ÒAdjustable
Differential Pressure SwitchesWeatherproof ÒÒÒ(SingleDiaphragm)
Weatherproof TerminalBlock ÒÒ(SingleDiaphragm) ExplosionProof ÒÒÒ(SingleDiaphragm)
ExplosionProofUL/CSA/ATEX ÒÒÒ(SingleDiaphragm)
BigHermetExplosionProof, ÒÒÒHermeticallySealed(SingleDiaphragm)
Level Switches FlangedChamber ÒÒÒSealedChamber ÒÒTop-MountedDisplacer ÒÒÒTop-MountedFloat ÒÒÒSideMounted ÒÒÒÒSteamTrap ÒÒÒOEMLevel ÒÒÒSingle-PointUltrasonic ÒÒÒÒSingle-PointUltrasonic ÒÒÒÒwithSelfTestDual-PointUltrasonic ÒÒÒÒwithSelfTestSingle-PointRF ÒÒÒSingle-PointRFwith ÒÒÒSelfTestMultipointRF ÒÒÒ
Level TransmittersUltrasonic ÒÒÒÒSubmersibleHydrostaticPressure ÒÒÒ
RF ÒÒÒ
Pressure SwitchesWeatherproof ÒÒÒ(Pressure/Vacuum/Compound) Weatherproof TerminalBlockConnections ÒÒ(Pressure/Vacuum/Compound)
ExplosionProof ÒÒÒ(Pressure/Vacuum/Compound)
ExplosionProof UL/CSA/ATEX ÒÒÒ(Pressure/Vacuum/Compound)
BigHermetExplosionProof,HermeticallySealed
ÒÒÒ
(Pressure/Vacuum/Compound)
3
Mini-HermetExplosionProof,Hermetically ÒÒÒSealed(SingleDiaphragm)
Weatherproof ÒÒ(DualOpposedDiaphragm)
ExplosionProof ÒÒÒ(DualOpposedDiaphragm)
Weatherproof ÒÒ(HighStaticOperation)
ExplosionProofHermeticallySealed ÒÒÒ(HighStaticOperation)Weatherproof(LowRange) ÒÒExplosionProofHermeticallySealed ÒÒÒ(LowRange)
Flow SwitchesThermalDifferential ÒÒÒÒVaneOperated ÒÒÒÒ
Temperature TransmittersMini-Hermit ÒExplosionProof,Adjustable
Temperature SwitchesWeatherproof
ÒÒÒ(DirectorRemoteMount)
WeatherproofTerminalBlockConnections ÒÒ(DirectorRemoteMount)
ExplosionProof ÒÒÒ(DirectorRemoteMount)
ExplosionProofUL/CSA/ATEX ÒÒÒ(DirectorRemoteMount)
BigHermetExplosionProof,Hermetically ÒÒÒSealed(DirectorRemoteMount)
Mini-HermetExplosionProof,Hermetically ÒÒÒSealed(DirectorRemoteMount)
NuclearQ
ualified
Chem
ical&Other
Power
Petrochemical
Oil&G
as
P r o d u c t A P P l i c At i o n s
NuclearQ
ualified
Chem
ical&Other
Power
Petrochemical
Oil&G
as
Level Switches
Product Model# Ranges Certifications Features andStandards
Flanged 100Series, vac-300+psi UL,CSA, •ServiceableflangedchamberChamber 741-743, vac-21bar ATEX,GOST •Stainlesssteelswitching(Refer to 801,802 SAA mechanismforharshatmospheresForm 912) -65˚-1000˚F ANSI/ASME -54˚-538˚C ASTMmaterials
Sealed 200Series, vac-300+psi UL,CSA, •Low-costsealedchamberChamber 740-803, vac-21bar ATEX,GOST •Stainlesssteelswitching(Refer to 801,802 SAA mechanismforharshatmospheresForm 912) -65˚-1000˚F ANSI/ASME -54˚-538˚C ASTMmaterials TopMounted 700Series, vac-1000psi UL,CSA, •Availablein1-or2-stageswitchingDisplacer 730-750 vac-69bar ATEX,GOST •Narrowandwidedifferential(Refer to SAA •StainlesssteelswitchingForm 912) -65˚-450˚F mechanismforharshatmospheres -54˚-232˚C ASTMmaterials
TopMounted 300Series vac-750psi UL,CSA, •Availablein1-or2-stageswitchingFloat vac-51bar ATEX,GOST •Stainlesssteelswitching(Refer to SAA mechanismforharshatmospheresForm 912) -65˚-450˚F -54˚-232˚C ASTMmaterials
SideMounted 400Series vac-1250psi UL,CSA, •Serviceableflangedchamber(Refer to vac-95bar ATEX,GOST •StainlesssteelswitchingForm 912) SAA mechanismforharshatmospheres -65˚-450˚F -54˚-232˚C ASTMmaterials
SteamTrap 108,208 vac-2248psi UL,CSA, •Serviceableflangedorsealedchamber(Refer to vac-135bar ATEX,GOST •StainlesssteelswitchingForm 912) SAA mechanismforharshatmospheres -65˚-1000˚F ANSI/ASME,GOST -54˚-538˚C ASTMmaterials
OEMLevel 1500Series, vac-1500psi CSA,GOST •Economicalside-andtop-mounted(Refer to 1710 vac-100bar ATEX versionsavailableForms 498, 500 and 864) -40˚-400˚F -40˚-204˚C ASTMmaterials
4
200Series740-803801802
100Series741-743801802
300Series
700Series730-750
400Series
108208
1500Series1710
651681
Product Model# Ranges Certifications Features
SinglePoint 701 0-2000psi FM,CSA, •LowcostUltrasonic 0-135bar GOST •Nocalibrationrequired(Refer to •Relayandcurrentshift(8/16mA)Form 1145) -40˚-250˚F outputavailable -40˚-121˚C •316SSsensor
SinglePoint 721 0-2000psi FM,CSA, •NocalibrationrequiredUltrasonicwith 0-135bar GOST •Relayandcurrentshift(8/16mA)SelfTest outputavailable (Refer to -40˚-250˚F •316SSsensor Form 1145) -40˚-121˚C
DualPoint 722 0-2000psi FM,CSA, •NocalibrationrequiredUltrasonicwith 0-135bar GOST •SetpointscanbelinkedSelfTest toprovide“pumplogic” (Refer to -40˚-250˚F •Relayandcurrentshift(8/16mA) Form 1145) -40˚-121˚C outputavailable •316SS,Alloy20,Hastelloy-CSensors SinglePointRF 651 vac-4000psi FM,CSA, •Lowcost(Refer to vac-275bar GOST •Single-pointswitchforalarmapplicationsForm 1100) •Relayandcurrentshift(8/16mA) -40˚-400˚F outputavailable -40˚-204˚C •Avarietyofprobeconfigurations meetmostapplicationconditions
SinglePointRF 681 vac-1500psi GOST •AdjustabledifferentialfeatureprovideswithSelfTest vac-100bar forpumpcontrol(Refer to •Relayandcurrentshift(8/16mA)Form 1100) -40˚-400˚F outputavailable -40˚-204˚C •Avarietyofprobeconfigurations meetmostapplicationconditions
MultipointRF 660Series vac-4000psi FM,CSA, •Uptofourpointslevelindication(Refer to vac-275bar GOST forpumpcontrolForm 1100) •Adjustabledifferentialfeature -40˚-400˚F providesforpumpcontrol -40˚-204˚C •Avarietyofprobeconfigurations meetmostapplicationconditions
5
701
Level Switches
721
660Series
722
Level Transmitters
Product Model# Ranges Certifications Features
echOsonixTM U71,U73 18in.(0.45m) CSA,GOST •Powerfultransmittedpulseforgreater(Refer to Forms to260ft.(80m) penetrationandflexibility1035 and 1185) •Automaticallyadjustedgaincontinually adaptstoprocessconditions •Echorecognitionallowsautomated false-echohandling •Superiorapplicationflexibility–dust,foam, condensation,angleofreposeare automaticallycompensated
Submersible 510LT 10-463ftwc ATEX,GOST •NoseconewithNPT(M)connectionHydrostatic 510SF (3-140m) EExia orflushsensordesignPressure •Unsplicedcablelengthsupto3,000ft.(Refer to •Rangesfrom10to463ftwcForm 1144) •Compact,316SShousing
RF 670Series Upto150ft. FM,CSA, •Continuouslevelmeasurementtransmitter(Refer to (45m) GOST •Measurementrangeupto150ft.Form 1100) •Loop-powered,intrinsicallysafe 4-20mAoutput •Avarietyofprobeconfigurationsmeet mostapplicationconditions
6
510LT510SF
U71
670SeriesU73
Product Model# Ranges Certifications Features
Weatherproof NN 30inHgvac-7000psi CSA,CE, •Lowcost(Pressure/Vacuum/Compound) 1barvac-480bar GOST •Setpointadjustmentwith(Refer to Form 216) calibratedscale Weatherproof,Terminal RN 30inHgvac-7000psi CSA,CE, •SetpointadjustmentwithBlockConnections 1barvac-480bar GOST calibratedscale(Pressure/Vacuum/Compound)(Refer to Form 216)
ExplosionProof L 30inHgvac-7000psi UL:ClassI, •Lowcost(Pressure/Vacuum/Compound) 1barvac-480bar GroupC,Div.1 •Setpointadjustmentwith(Refer to Form 216) (asanoutletbox) calibratedscale GOST ExplosionProof, B3 30inHgvac-7000psi UL/CSA:ClassI, •TerminalblockconnectionsUL/CSA/ATEX 1barvac-480bar GroupB,Div.1; •Setpointadjustmentwith(Pressure/Vacuum/Compound) ATEX:EExdIICT6, calibratedscale(Refer to Form 216) GOST •Setpointadjustment withoutdeclassification ofhazardousarea
BigHermet-Explosion Big 30inHgvac-7000psi Unit: •HermeticallysealedProof,HermeticallySealed Hermet 1barvac-480bar UL/CSA:ClassI, snapswitch(es)(Pressure/Vacuum/Compound) GroupA,Div.1; •Setpointadjustment (Refer to Form 455) SnapSw: withoutdeclassification UL/CSA,SAA, ofhazardousarea GOST
Mini-Hermet-Explosion Mini- 30inHgvac-7000psi Unit: •HermeticallysealedProof,HermeticallySealed Hermet 1barvac-480bar UL/CSA:ClassI, snapswitch(es)(Pressure/Compound) GroupA,Div.1; •Setpointadjustment (Refer to Form 456) ATEX:EExdIIC withoutdeclassification SnapSw: ofhazardousarea UL/CSA,ATEX, SAA,GOST
7
NN
RN L
B3
BigHermet
Mini-Hermet
Pressure Switches
Product Model# Ranges Certifications Features
DualHi-Lo-Weatherproof V1 30inHgvac-4000psi CSA,CE, •Dualsetpoints(Pressure/Vacuum/Compound) 1barvac-275bar GOST •Setpointadjustment(Refer to Form 217) withcalibratedscale
DualHi-Lo-Explosion V2 30inHgvac-4000psi Unit: •DualsetpointsProofHermeticallySealed 1barvac-275bar UL/CSA:ClassI, •Hermeticallysealed(Pressure/Vacuum/Compound) GroupA,Div.1; snapswitches(Refer to Form 217) SnapSw: •Setpointadjustmentwith UL/CSA,ATEX, calibratedscale SAA,GOST •Setpointadjustment withoutdeclassification ofhazardousarea
Omni-Weatherproof Omni 7-7000psi GOST •Environmentallysealed(Pressure) 0.5-480bar snapswitches (Refer to Form 987) snapswitches
SubMini-Hermet-Explosion Sub 8-200psi SnapSw: •HermeticallysealedProof,HermeticallySealed Mini- 0.5-14bar UL/CSA,ATEX, snapswitch(es)(Pressure) Hermet SAA,GOST •Setpointadjustment(Refer to Form 987) withoutdeclassification ofhazardousarea
Pressure Switches
8
V1
V2
Omni
SubMini-Hermet
Product Model# Ranges Certifications Features
ElectronicPressure 2SGT 30inHgvac-2000psig UL/cUL:ClassI, •DualsetpointswithInstrument -1.0-135bar GroupA,Div.2; programmabledeadbands(Refer to Form 1301) ATEX:EExnLIIC, •150%URLGageindicationwith 10-2000psia GOST programmableengineeringunits 0.7-135barabs. •4-20mA,loop-poweredoutput withprogrammable5:1turndown •Selfdiagnosticswithmanual circuittests •Localprogrammingwithout declassificationorhazardousarea
Weatherproof,FixedRange 503FR 5-2000psi ATEX:EExia, •Lowcost(Refer to Form 1173) .34-140bar GOST •Environmentallysealed electricalconnection
Immersible,FixedRange 510IM 5-2000psi ATEX:EExia, •Suitableforcontinuous(Refer to Form 1174) .34-140bar GOST liquidimmersion •Compact,316SShousing
Mini-Hermet-Explosion 534CR, 10-15,000psi FM/CSA:ClassI, •4-20mA,looppoweredorProof,Adjustable 534HS, .69-1000bar GroupA,Div.1, 1-5Vdc,low-poweroutputs(Refer to Forms 1175, 536CR, EXPL/IS,GOST •Calibrationwithoutdeclassification1176, 1177 and 1178) 536HS ofhazardousarea •Hermeticallysealedelectrical connectionandzero/span adjustments •5:1turndown (4:1turndownon534CR)
Pressure Transmitters
9
2SGT
503FR
510IM
534CR534HS536CR536HS
Product Model# Ranges Certifications Features
Weatherproof 101NN, 3-500psid CSA,CE,GOST •Lowcost(Singlediaphragm) 121NN .2-35bar •Setpointadjustmentwith(Refer to Form 468) calibratedscale Weatherproof,TerminalBlock 101RN, 3-500psid CSA,CE,GOST •Setpointadjustmentwith(Singlediaphragm) 121RN .2-35bar calibratedscale(Refer to Form 468)ExplosionProof 101L, 3-500psid UL:ClassI,GOST •Lowcost(Singlediaphragm) 121L .2-35bar GroupC,Div.1 •Setpointadjustmentwith(Refer to Form 468) (asanoutletbox) calibratedscale ExplosionProof, 101B3, 3-500psid UL/CSA:ClassI, •TerminalblockconnectionsUL/CSA/ATEX 121B3 .2-35bar GroupB,Div.1; •Setpointadjustmentwith(Singlediaphragm) ATEX:EExdIICT6, calibratedscale(Refer to Form 468) GOST •Setpointadjustment withoutdeclassification ofhazardousarea
BigHermet-Explosion Big 3-500psid Unit: •HermeticallysealedProof,HermeticallySealed Hermet .2-35bar UL/CSA:ClassI, snapswitch(es)(Singlediaphragm) GroupA,Div.1; •Setpointadjustment (Refer to Form 468) SnapSw: withoutdeclassification UL/CSA,SAA,GOST ofhazardousarea
Mini-Hermet-Explosion Mini- 3-500psid Unit: •HermeticallysealedProof,HermeticallySealed Hermet .2-35bar UL/CSA:ClassI, snapswitch(es)(Singlediaphragm) GroupA,Div.1; •Setpointadjustment (Refer to Form 468) ATEX:EExdIIC; withoutdeclassification SnapSw: ofhazardousarea UL/CSA,ATEX,SAA, GOST
101B3121B3
Differential Pressure Switches
Mini-Hermet
BigHermet
10
101NN121NN
101L121L
101RN121RN
Product Model# Ranges Certifications Features
Weatherproof RB 0.5-1000psid CSA,CE,GOST •Terminalblockconnections(Dual,opposeddiaphragm) 35mbar-70bar •Setpointadjustmentwith(Refer to Form 386) calibratedscale ExplosionProof S 0.5-500psid UL:ClassI, •Set-pointadjustmentwith(Dual,opposeddiaphragm) 35mbar-70bar GroupC,Div.1 calibratedscale(Refer to Form 386) (asanoutletbox), GOST
Weatherproof 102W1 7inwc-2500psid CSA,GOST •Negligibletemperature(High-staticoperation) 103W1 18mbar-175bar and/orstaticinfluence(Refer to Form 388)
ExplosionProof, 102AD, 7inwc-2500psid Unit: •NegligibletemperatureHermeticallySealed 103AD 18mbar-175bar ATEX:EExdIIC; and/orstaticinfluence(High-staticoperation) SnapSw: •Hermeticallysealed(Refer to Form 388) UL/CSA,ATEX, snapswitch(es) SAA,GOST •Setpointadjustment withoutdeclassification ofhazardousarea
Weatherproof 107AL 0.25-40inwd FM,CSA,GOST •Setpointadjustmentwith (Lowrange) 6.4-1000mmwc calibratedscale(Refer to Form 459)
ExplosionProof, 107EL 0.3-40inwd SnapSw: •HermeticallysealedHermeticallySealed 7.5-1000mmwc UL/CSA,ATEX, snapswitch(es)(Lowrange) SAA,GOST •Setpointadjustment(Refer to Form 459) withoutdeclassification ofhazardousarea
102W1103W1
11
S
RB
107EL
107AL
102AD103AD
Differential Pressure Switches
900Series
Flow Switches
Product Model# Features
ThermalDifferential T21 •Wideoperatingprocesstemperaturerangeof-100˚Fto392˚F(Refer to Form 1021) •Removable,plug-inelectronicsboard •Self-heatingsensordesign VaneOperated 900Series •Stainlesssteelswitchingmechanismforharshatmospheres(Refer to Form 672) •AllASTMmaterialsconstruction •Flowmonitoringforawiderangeofpipesizesandspecificgravities
12
T21
Temperature Switches
BigHermet
Mini-Hermet
13
NN
B3
L
RN
Product Model# Ranges Certifications Features
Weatherproof NN -50˚-1000˚F CSA,CE,GOST •Lowcost(Directorremotemount) -45˚-540˚C •Setpointadjustment(Refer to Form 220) withcalibratedscale Weatherproof,Terminal RN -50˚-1000˚F CSA,CE,GOST •TerminalblockconnectionsBlockConnections -45˚-540˚C •Setpointadjustmentwith(Directorremotemount) calibratedscale(Refer to Form 220)
ExplosionProof L -50˚-1000˚F UL:ClassI, •Lowcost(Directorremotemount) -45˚-540˚C GroupC,Div.1 •Setpointadjustmentwith(Refer to Form 220) (asanoutletbox), calibratedscale GOST ExplosionProof, B3 -50˚-1000˚F UL/CSA:ClassI, •TerminalblockconnectionsUL/CSA/ATEX -45˚-540˚C GroupB,Div.1; •Setpointadjustmentwith(Directorremotemount) ATEX:EExdIIC, calibratedscale(Refer to Form 220) GOST •Setpointadjustmentwithout declassificationofhazardousarea
BigHermet-Explosion BigHermet -50˚-1000˚F Unit: •Hermeticallysealedsnapswitch(es)Proof,HermeticallySealed -45˚-540˚C UL/CSA:ClassI, •Setpointadjustmentwith (Directorremotemount) GroupA,Div.1; calibratedscale (Refer to Form 220) SnapSw: •Setpointadjustmentwithout UL/CSA,SAA,GOST declassificationofhazardousarea
Mini-Hermet-Explosion Mini-Hermet -50˚-1000˚F Unit: •Hermeticallysealedsnapswitch(es)Proof,HermeticallySealed -45˚-540˚C UL/CSA:ClassI, •Setpointadjustmentwithout(Directorremotemount) GroupA,Div.1; declassificationofhazardousarea (Refer to Form 220) ATEX:EExdIIC; SnapSw: UL/CSA,ATEX,SAA, GOST
SOR products satisfy the requirements of approval agencies worldwide. Often,
a common design is capable of multiple approvals. In other cases, modified
construction techniques are necessary to meet specific agency requirements.
Hazardous Areas are locations where the potential for fire or explosion exists because
of gases, dust or easily ignitable fibers or flyings in the atmosphere.
In North america, hazardous areas are separated by classes, divisions, and
groups to define the level of safety required for equipment installed in these locations.
Classes define the general form of the flammable materials in the atmosphere. Divisions
define the probability of the presence of flammable materials. Groups classify the exact
flammable nature of the material.
In europe and countries outside of North america, classification of hazardous areas
is accomplished differently. Zones are used to define the probability of presence of the
flammable materials. Protection Types denote the level of safety for the device. Groups
classify the exact flammable nature of the material. These groups are separated differently
than North American Groups. Temperature Identifications convey the max imum surface
temperature of the apparatus based on 104°F (40°C) ambient. These temperature codes
are selected carefully so as not to exceed the ignition temperature of the specific gas or
vapor to be encountered in the application.
Similar to hazardous location classifications, environmental protection ratings are
slightly different within and outside of North America. National Electrical Manufacturers
Association (NEMA) and Ingress Protection (IP) Codes provide similar information
regarding protection against specified environmental conditions.
NeMa 4 Indoor or outdoor use. Protection against wind-blown dust and rain, splashing water, hose-directed water and damage from external ice formation.
NeMa 4X NEMA 4, plus protection against corrosion.
IP 65 Dust-tight and protected against water jets.
IP 68 Dust-tight and suitable for indefinite immersion.
Some classifications are not shown here. For further detailed information, see
specific standards published by approval organizations.
approval agencies
Hazardous area Classification
environmental Protection
14
Underwriters LaboratoriesFactory Mutual
Canadian Standards Association
ATEX (BASEEFA, DEMKO, KEMA, SIRA)
CE Marked: EMC Directive 89/3367/EEC
Heavy Industrial (Self-Certified)
GOST
Japanese Industrial Jis/riisAustralia Standards AssociationsAA
3A
SASO
Standards
Classifications Outside North america
Zone 0 Area in which an explosive gas-air mixture is continuously present or present for long periods.Zone 1 Area in which an explosive gas-air mixture is likely to occur in normal operation.Zone 2 Area in which an explosive gas-air
mixture is not likely to occur, and if it occurs it will only exist for a short time.
(Zones 0 and 1 are similar to North American Div. 1 classification. Zone 2 is similar to North American Div. 2 classification.)
Protection Types Specific to Zone d Flameproof (Explosion- proof) Enclosure 1, 2 e Increased Safety 1, 2 ia Intrinsic Safety 0, 1, 2 ib Intrinsic Safety 1, 2 o Oil Immersion 2 p Pressurized (Purged) Apparatus 1, 2 q Powder Filling (Sand Filling) 2 m Encapsulation 1, 2 n Normally Non-sparking 2 and/or Non-incendive Circuits
Group I For application in below-ground installations (mines) where methane (firedamp) and coal dust may be present.
Group IIa For application in above-ground installations where hazards due to propane may exist. (This group most closely matches the North American Group D.)
Group IIB For application in above-ground installations where hazards due to ethylene may exist. (This group most closely matches the North American Group C.)Group IIC For application in above-ground
installations where hazards due to hydrogen or acetylene may exist. (This group most closely matches the North American Groups A
and B.)
Temperature Codes T1 842°F 450°C T2 572°F 300°C T3 392°F 200°C T4 275°F 135°C T5 212°F 100°C T6 185°F 85°C
This brochure is intended to provide suggestions for the general application of certain types of instruments. Since each application has unique characteristics, it is recommended that you consult SOR to discuss the specific details of your application to ensure the correct instrument is selected.
Classifications Inside North america
Class I Flammable gases or vapors are present in the air in quantities
sufficient to produce explosive or ignitable mixture.
Class II Combustible or conductive dusts are present.
Class III Ignitable fibers or flyings are present but not likely to be in suspension in sufficient quantities to produce ignitable mixtures. (Group classifications are not applied to this class.)
Division 1 The substance referred to by class is present during normal conditions.
Division 2 The substance referred to by class is present only in abnormal conditions, such as a container failure or system breakdown.
Group a Acetylene
Group B Hydrogen (or gases of equivalent hazard)
Group C Ethylene (or gases of equivalent hazard)
Group D Gasoline (or gases of equivalent hazard)
Group e Metal Dust
Group F Coal Dust
Group G Grain Dust
15
www.sorinc.com
Japanese Industrial Jis/riis
16
Chemical Seals
SOR Chemical Seals are custom-
manufactured by ReoTemp Instruments, a
leading supplier of diaphragm seals with
many years of experience in specialty seals.
SOR is ready to work with customers on any
high-performance chemical seal application
such as high vacuum, high temperature,
high sterility, custom design, high static
pressure/low differential span or high
vacuum/high temperature.
Wireless SOR pressure, level and temperature switches
can easily be converted to operate in a
wireless mode with the
customer’s choice
of transmitter.
ProductRangeCertificationsFeatures
ThreadedSeals •IsolatessensorRegularorlarge(moresensitive) 30"inHGvac-2500 •All316S.S.diaphragm.Withorwithout •Weldedconstructionflushingport. •Customassemblies& materialsavailable FlangesSeals •IsolatessensorRegularorlarge(moresensitive) 30"inHGvac-2500 •All316S.S.diaphragm.Forpipesizes:1,11/2", •Weldedconstruction2,3,or4".Withorwithoutflushingport. •Customassemblies& materialsavailable
SanitarySeals •SanitaryisolationofsensorTri-Clampdesignfor:3/4",1", 30"inHGvac-600psi3A •Quickconnectingtri-clamp11/2",2,21/2"or3"pipe •Meets3Asanitarystandards
Custom Manufacturing
From the latest computer-driven machining tools to robotic
welders, SOR is loaded with manufacturing experience.
Our mixed-mode capabilities enable us to operate in
a job shop environment with an OEM mentality.
We specialize in short-run/quick-turn projects,
but can also handle high-volume work.
Compliant10CFR50, Appendix BANSI N45.2 NQA-1 (including reporting)ASME Section III, subsection NC and ND
Qualified by a combination of testing and analysis IEEE-323-1974 & 1983 IEEE-344-1975 & 1987
audited Nuclear Procurement Issues Committee (NUPIC)Nuclear Industry Assessment Committee (NIAC) Canadian Technical Standards & Safety Authority (TSSA) N285.0 Registered Quality System to ISO 9001:2000
17
SOR custom engineers nuclear-qualified pressure, temperature and vacuum switches.
Our engineering expertise is specifically targeted to meet the unique demands of the
nuclear power generation industry and provide solutions.
Nuclear Qualified Products
SOR is uniquely positioned to help its customers with their business-to-business
marketing communications efforts. Our Marketing department has researched, planned,
written, video-taped, printed, coordinated and produced promotions, Web sites, corporate
and training videos, point-of-purchase displays and more for industrial and consumer
companies worldwide.
Our integrated approach uses the latest multimedia technologies to move your message
from concept to culmination. While other companies must depend on outside services to
complete projects, at SOR and its sister company Digital Lagoon, everything you need is
under one roof. We understand the world of industrial marketing and can provide the right
medium that generates sales leads and gets results.
• creative services – Concept, copy and design
• Web site interface design – Flash, 2-D and 3-D animation
• Web development – e-commerce, e-training, Web solutions,
streaming media and Web site registration
• large Format Printing – State-of-the-art flatbed press, 3-D and motion
lenticular printing, high quality, cost-efficient and fast turnaround
• Web Hosting – Leading edge data center, power and tier 1 bandwidth
redundancy, firewall, Web trends reports and real-time monitoring
• Video Production – Studio and location videography, editing, scripting,
narration, compression and production
• cd-roM and Kiosk development, Sales and marketing
demos, CD-ROM catalogs and computer-based training
• dVd Authoring – Video sales and training presentations
Marketing Communications
www.lagoon.com
Process Instrumentation
Form901(11.07)©2007SORInc.Registered Quality System to ISO 9001:2000
Pre
ssu
re
Flow
Tem
pera
ture
Level
We Deliver Quality On Time
SOR europe, Ltd.StarRoadPartridgeGreen,SussexRH138RA,UnitedKingdom
SOR Inc.14685West105thStreetLenexa,Kansas66215
Phone913-888-2630TollFree800-676-6794Fax913-888-0767
www.sorinc.comwww.echOsonix.com
SOR - ChinaRoom903,No.10BuildingWanDaPlazaNo.93JianGuoRoadChaoYangDistrictBeijing,China100022
Phone+86(10)58208767Fax+86(10)58208770