107
PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW PLASTICITY BURNISHING OF SE508 NITINOL ALLOY by JOHN ELLIS MCKINNEY JR YUEBIN B. GUO, COMMITTEE CHAIR MARK L. WEAVER BRIAN J. JORDON A THESIS Submitted in partial fulfillment of the requirements for the degree of Master of Science in the Department of Mechanical Engineering in the Graduate School of The University of Alabama TUSCALOOSA, ALABAMA 2013
Transcript
Page 1: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW PLASTICITY

BURNISHING OF SE508 NITINOL ALLOY

by

JOHN ELLIS MCKINNEY JR

YUEBIN B. GUO, COMMITTEE CHAIR

MARK L. WEAVER

BRIAN J. JORDON

A THESIS

Submitted in partial fulfillment of the requirements

for the degree of Master of Science

in the Department of Mechanical Engineering

in the Graduate School of

The University of Alabama

TUSCALOOSA, ALABAMA

2013

Page 2: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

Copyright John Ellis McKinney 2013

ALL RIGHTS RESERVED

Page 3: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

ii

ABSTRACT

Superelastic Nitinol and shape memory alloys have attracted growing attentions over the

recent years in the areas of biomedical and aerospace applications. Surface integrity of Nitinol

devices by various fabrication processes is critical for their functionality and performance. Low

plasticity burnishing (LPB) is a surface enhancement process to improve surface integrity due to

its unique capability to plastically deform material in the deep subsurface on the order of a 500-

1000μm. This thesis focuses on the dynamic mechanical behavior of SE508 Nitinol (NiTi) alloy

and process mechanics and surface integrity by ball burnishing of the material.

The stress-strain behaviors of SE508 NiTi alloy at quasi-static and high strain rates were

experimentally determined using a series of compression testing. Then, the experimentally

determined stress-strain behavior was used in correlation with Hertzian theory of contact

mechanics in ball burnishing of the material. It was found that quasi-static compressive stress-

strain behavior correlates well with Hertzian peak pressure. This serves as a basis to select

burnishing loads. The effects of LPB parameters, i.e. burnishing pressure, feed, speed, number of

path, and pattern on surface integrity characteristics such as surface topography, roughness,

microhardness, and microstructure are investigated.

Page 4: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

iii

DEDICATION

This thesis is dedicated to my family and friends as well as everyone who provided

guidance through the consortium of efforts in this research. I dedicate this work to my creators

and for the love of engineering science.

Page 5: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

iv

LIST OF ABBREVIATIONS AND SYMBOLS

Af Austenite finish temperature

As Austenite start temperature

Mf Martensite finish temperature

Ms Martensite start temperature

E* Effective elastic modulus

E1 Elastic modulus of tool

E2 Elastic modulus of workpiece

Ea Austenite modulus (NiTi)

Em Martensite modulus (NiTi)

1 Poisson’s ratio of tool tip

2 Poisson’s ratio of workpiece

R Effective curvature

R1 Tool curvature

R2 Workpiece curvature

F Burnishing force

P Burnishing pressure

a Contact radius

Mutual approach

Page 6: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

v

0p Hertz peak pressure

3,2,1 Stress elements

Y Yield strength

1 Maximum shear stress

r Maximum tensile stress

Ra Surface roughness

Page 7: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

vi

ACKNOWLEDGEMENTS

I am thankful to have had the opportunity to work with some great people through the

endeavors of this research. I am most indebted to Dr. Yuebin Guo for initiating this research

project through financial support while providing technical guidance. I am thankful for the

leadership and wisdom on many levels that was provided during the course of my studies at The

University of Alabama. I would like to extend a special thanks to Dr. Mark Barkey and Dr. Mark

Weaver for their help and guidance on an academic level.

I am also grateful to have had the experience to work with some great colleagues who

were helpful and supportive through the endeavors of rigorous research and those people are:

John Snyder, Chenhao Fu, Meisam Salahshoor, Wei Li, Hardik Singh, and Roberto Caslru.

Special thanks go to my parents who have always supported and encouraged me not only

for this research but in all my endeavors. I would also like to thank all my family members and

friends for their support over the years which made me capable of having this accomplishment.

Finally, I would like to thank The Mechanical Engineering Department at The University of

Alabama for providing an excellent academic environment to carry out this project.

Page 8: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

vii

CONTENTS

ABSTRACT .................................................................................................................................... ii

DEDICATION ............................................................................................................................... iii

LIST OF ABBREVIATIONS AND SYMBOLS .......................................................................... iv

ACKNOWLEDGEMENTS ........................................................................................................... vi

LIST OF TABLES ......................................................................................................................... xi

LIST OF FIGURES ...................................................................................................................... xii

1. INTRODUCTION ......................................................................................................................1

2. A LITERARY REVIEW ON NITINOL ALLOYS AND PROCESSING ................................3

Abstract ............................................................................................................................................3

2.1 Introduction ................................................................................................................................4

2.1.1 The discovery and debut of Nitinol ........................................................................................4

2.1.2 Nitinol implants and applications ...........................................................................................4

2.1.3 Critical issues for implants......................................................................................................6

2.2 Nitinol phase transformation......................................................................................................6

2.3 Nitinol mechanical properties ..................................................................................................11

2.3.1 Stress-strain characteristics ...................................................................................................11

2.3.2 Superelastic behavior of Nitinol ...........................................................................................15

2.4 Biocompatibility of Nitinol ......................................................................................................16

2.5 Fatigue life of Nitinol...............................................................................................................19

Page 9: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

viii

2.6 Crack growth behavior .............................................................................................................23

2.7 Issues and future research of Nitinol .......................................................................................26

References ......................................................................................................................................28

3. CHARACTERIZATION OF MICROSTRUCTURE AND DYNAMIC MECHANICAL

PROPERTIES OF A BIOMEDICAL NITINOL ALLOY ...........................................................31

Abstract .........................................................................................................................................31

3.1 Introduction ..............................................................................................................................32

3.2 NiTi SE508 fabrication and sample preparation ......................................................................35

3.2.1 Material fabrication ...............................................................................................................35

3.2.2 Sample preparation ...............................................................................................................36

3.3 Experimental procedures .........................................................................................................36

3.3.1 Quasi-static compression testing...........................................................................................36

3.3.2 High strain rate Split-Hopkinson pressure bar testing procedure .........................................37

3.4 Experimental results.................................................................................................................40

3.4.1 Stress-strain curves ...............................................................................................................40

3.4.2 Microstructural characterization ...........................................................................................41

3.5 Conclusions ..............................................................................................................................46

References ......................................................................................................................................48

4. PROCESS MECHANICS OF BALL BURNISHING OF SE508 NITI ALLOY ....................50

Abstract ..........................................................................................................................................50

4.1 Introduction ..............................................................................................................................51

4.1.1 SE508 NiTi ...........................................................................................................................51

4.1.2 How to improve fatigue life ..................................................................................................53

Page 10: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

ix

4.2 LPB method .............................................................................................................................54

4.2.1 Experimental setup................................................................................................................54

4.2.3 Work material .......................................................................................................................56

4.3 LPB process analysis ...............................................................................................................57

4.3.1 Burnishing pressure/force .....................................................................................................57

4.4 Hertz maximum contact pressure relation ...............................................................................58

4.5 Burnished depth/width .............................................................................................................60

4.6 Maximum shear stress and location in the subsurface .............................................................62

4.7 Experimental characterization of LPB tracks ..........................................................................65

4.8 Conclusions ..............................................................................................................................67

References ......................................................................................................................................68

5. SURFACE INTEGRITY OF BALL BURNISHING OF SE508 NITI ....................................71

Abstract ..........................................................................................................................................71

5.1 Introduction ..............................................................................................................................71

5.2 LPB method .............................................................................................................................74

5.2.1 Experimental setup................................................................................................................74

5.2.2 Work material .......................................................................................................................76

5.3 LPB process analysis ...............................................................................................................77

5.3.1 LPB load cases ......................................................................................................................77

5.3.2 LPB contact mechanics .........................................................................................................79

5.4 Experimental characterization of LPB tracks ..........................................................................82

5.4.1 Surface profiles at varied LPB load cases .............................................................................82

Page 11: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

x

5.4.2 Optical image results/grain boundary characterizations .......................................................84

5.4.3 Surface/subsurface microhardness ........................................................................................86

5.5 Conclusions ..............................................................................................................................88

References ......................................................................................................................................90

6. SUMMARY ...............................................................................................................................92

Page 12: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

xi

LIST OF TABLES

Table 4.1 Composition of SE508 Nitinol ......................................................................................56

Table 4.2 Input parameters for Hertzian contact theory ................................................................58

Table 4.3 Spherical indentation and optimal LPB parameters experimental plan .........................59

Table 4.4 LPB pressure input parameters ......................................................................................62

Table 5.1 SE508 NiTi composition by weight percentage ............................................................77

Table 5.2 Parameters investigated for optimal LPB of SE508 NiTi..............................................78

Page 13: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

xii

LIST OF FIGURES

Fig. 2.1 Stress-strain characteristics of NiTi, stainless steel, and biological tissue .........................5

Fig. 2.2 Transformation and detwinning during a thermal cycle (tension) ....................................7

Fig. 2.3 Phase transformation corresponding to stress, strain, and temperature ..............................8

Fig. 2.4 Lattice change during the evolution of the R-phase transformation ................................10

Fig. 2.5 Varying heat treatment times in the case of cooling and heating .....................................11

Fig. 2.6 Martensite transformation with induced stress and strain ................................................12

Fig. 2.7 Tensile stress-strain response of Nitinol alloy with low-cycle fatigue .............................13

Fig. 2.8 Hysteresis width and area with fatigue cycles ..................................................................14

Fig. 2.9 Stress-strain behavior of Nitinol with varying porosity ...................................................15

Fig. 2.10 Stress amplitude vs cycles for an austenitic and martensitic Nitinol allo ......................20

Fig. 2.11 Hysteresis comparison of Nitinol and pearlitic steel ......................................................21

Fig. 2.12 Fatigue crack growth behavior of Nitinol tube ...............................................................24

Fig. 2.13 Crack growth of a Nitinol wire .......................................................................................25

Fig. 2.14 Crack behavior of a notched NiTi specimen ..................................................................26

Fig. 3.1 Early development NiTi device ........................................................................................33

Fig. 3.2 Phase diagram of a nickel-titanium binary alloy ..............................................................35

Fig. 3.3 Split Hopkinson test setup ................................................................................................38

Fig. 3.4 Split Hopkinson test specimen .........................................................................................40

Fig. 3.5 Dynamic stress-strain behavior of SE508 NiTi ................................................................41

Fig. 3.6 Schematic of the transformation and detwinning processes .............................................42

Page 14: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

xiii

Fig. 3.7 The evolution of the R-phase transformation ...................................................................43

Fig. 3.8 Nitinol grain boundary optical images .............................................................................44

Fig. 3.9 SEM images of etched Nitinol surfaces ...........................................................................45

Fig. 3.10 Nitinol grain size distribution post compression test......................................................46

Fig. 4.1 Phase diagram of a nickel-titanium binary alloy ..............................................................52

Fig. 4.2 LPB tool details ................................................................................................................54

Fig. 4.3 Test fixture for LPB experimental work...........................................................................55

Fig. 4.4 Quasi-static mechanical properties in compared Hertz peak pressure .............................60

Fig. 4.5 Contour plot illustrating shear stress distribution .............................................................64

Fig. 4.6 The comparison of burnishing pressure and indentation depth ........................................66

Fig. 5.1 LPB EcoRoll tool and test fixture.....................................................................................75

Fig. 5.2 LPB coverage patterns ......................................................................................................78

Fig. 5.3 Experimental stress-strain compared to Hertz theoretical ................................................79

Fig. 5.4 The comparison to LPB pressure and surface roughness .................................................83

Fig. 5.5 The comparison of grain size and LPB loading pressure .................................................85

Fig. 5.6 Grain characterization with varied LPB tool pressure ......................................................86

Fig. 5.7 The comparison of microhardness and depth ...................................................................87

Page 15: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

1

INTRODUCTION

Nitinol (NiTi) is a nickel-titanium alloy of near equiatomic composition with superelastic

mechanical properties as well as shape memory properties. Slight variations in the binary alloy

composition change the mechanical properties significantly with this particular material;

moreover, heat treatment history and finishing of the material play a vital role in the mechanical

properties as well. As a result, these material properties are critical to various biomedical and

aerospace applications. Nitinol was first discovered in the early 1960’s and some of the first

experimental work was conducted by the Naval Ordinance Laboratory where many of the early

applications of Nitinol focused on the shape memory mechanical properties of NiTi.

With slight variation of nickel presence in the nearly equiatomic Nitinol alloy, there is a

distinction of enhanced shape memory or super elastic properties. The designation of shape

memory NiTi is denoted by SM495 where super elastic NiTi is denoted as SE508. In the recent

years, a lot of attention has been aimed toward the superelastic properties of Nitinol with

particular emphasis on biomedical applications. SE508 NiTi has superelastic features well below

the melting point where a diffusionless phase transformation occurs from an austenite to

martensite state allowing this phenomenon to occur. It is also of interest that SE508 NiTi has

elastic behavior that has similar characteristics to human biological tissue. Although SE508 NiTi

serves as an excellent biomaterial, there are concerns with nickel leeching while in vivo as

literature may suggest. This would have adverse effects on the structural integrity of a NiTi

implant and therefore reduce the fatigue life.

Page 16: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

2

It is of importance to have a high quality surface integrity of a NiTi implant such that the

life of the implant has a lasting effect while not being detrimental to the patient. The two primary

contributing factors to influence longer fatigue life and corrosion resistance are compressive

residual stresses and protective surface layers. Adequate heat treating of NiTi is a necessary

practice to create a titanium oxide layer that is critical for corrosion resistance of a NiTi medical

device. In the event of surface modification, electro-polishing follows thereafter to generate a

uniform protective oxide layer. One of the more novel surface modification methods is low

plasticity burnishing (LPB). Ball burnishing is a superior surface enhancement process that

induces large compressive residual stresses with little cold work. Minimal amounts of cold work

are desired on the premise that elastic properties are not compromised. Ball burnishing is a

process where an extremely hard ceramic ball passes over a workpiece at high pressures to

induce deep subsurface residual stresses. Hertz theory of contact mechanics is a classical method

that can be used to predict elastic behavior for the primary parameters inherent to LPB. The

ability to predict the onset of plastic behavior in such a process sheds light to surface integrity

formation.

This work starts with a literature review on NiTi alloys and processing methods.

Microstructure and dynamic mechanical properties of SE508 NiTi alloy were characterized.

Then, process mechanics of ball burnishing of SE508 NiTi alloy was analyzed based on Hertz

theory of contact mechanics. Lastly, surface integrity in terms of surface topography, roughness,

microhardness, and microstructure of ball burnishing of SE508 NiTi are characterized.

Page 17: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

3

CHAPTER 2

A LITERARY REVIEW ON NITINOL ALLOYS AND PROCESSING

Abstract

In the more recent years, there has been a lot of emphasis on biomedical applications for

Nitinol (NiTi) alloys with particular interest in superelastic properties. These particular

superelastic properties are similar to biological tissue and are desirable for biomedical devices.

However, nickel based alloys are generally unstable in corrosive environments and this brings

forth questionable biocompatibility for a material such as NiTi. Initially, there was concern in

regard to the biocompatibility of NiTi. Through the years, NiTi has surfaced as a superior

biomaterial in comparison to other biomaterials. Through the years of development with NiTi

based applications, it was discovered that with adequate heat treatment and passivation that the

stability of NiTi as a biomaterial has no signs of adverse interaction. The stress-strain

characteristics of NiTi are advantageous as a biomaterial on the premise that other candidate

materials are not as elastically permissible. On the grounds that NiTi serves as an excellent

biocompatible material, that is resistant to fatigue, there exists a global interest in the capacity to

advance current medical practices and procedures. This literary review encompasses the

evolution of NiTi to from early to modern applications and as well as current interests in the use

of NiTi as a biomaterial.

Page 18: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

4

2.1 Introduction

2.1.1 The discovery and debut of Nitinol

Nitinol (NiTi) is a nickel-titanium alloy of near equiatomic composition with pseudo-

elastic mechanical properties. Slight variations in the binary alloy composition change the

mechanical properties significantly; moreover, heat treatment history and finishing of the

material play a vital role in the mechanical properties as well. Typically, superelastic behavior in

metals occurs at elevated temperatures that approach the melting point of the material. NiTi is

composed of nickel and titanium with trace elements and the accompanying characteristics of

this particular binary alloy distinguish overall properties of a superalloy yet NiTi has superelastic

features well below the melting point. NiTi is not only superelastic but also has shape memory

properties, which are rather elegant to say the least. As a result, these material properties are

advantageous to various biomedical and aerospace applications. NiTi was first discovered in the

early 1960’s and some of the first experimentations were conducted by the Naval Ordinance

Laboratory. The term Ni-Ti-Nol was brought about by the composition of this nickel-titanium

binary alloy and the development of the material conducted by the Naval Ordinance Laboratory.

The public introduction of NiTi was formally brought about in 1968 and thereafter a series of

devices were patented in the regard of using the mechanical energy from NiTi where many were

unsuccessful.

2.1.2 Nitinol implants and applications

In more recent years, Nitinol has become increasingly popular for biomedical

applications in light of mechanical properties that are similar to human biological tissue. Nitinol

Page 19: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

5

has also proven to have stable biocompatibility both in vitro and in vivo as literature would

suggest. Biocompatibility is an essential characteristic of an implant device. The two primary

parameters that determine the biocompatibility of a given material are the host reactions from the

material and the environment of the body [1]. Some of the first known medical applications of

Nitinol were successfully developed dating back to the 1970’s. These particular applications

include dental arch wire, vena cava filter, and suture anchors for orthopedic surgery. Later in the

1990’s, further development of biomedical applications were successfully carried out with an

increase in interest throughout the medical community. Such applications include urethral,

esophageal, and vascular stents as well as aneurysm prostheses, and various orthopedic implants.

The mechanical properties of NiTi offer a critical advantage over other materials such that the

mechanical characteristics of superelasticity have the ability to mimic similar mechanics of

intracellular tissues as observed in Fig. 2.1.

Fig. 2.1 General stress-strain characteristics for Nitinol, stainless steel, bone, and tendon tissue [2]

Page 20: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

6

2.1.3 Critical issues for conventional metallic implants

There are a number of factors that encompass conventional metallic biomedical implants.

One of the key issues is the dissolutions of metallic ions while in vivo where the dissolution of

ions may lead to allergenic reactions to the body of the implant recipient and therefore must be

avoided at all cost. Surface characteristics such as passive layers and compressive residual

stresses play a vital role in the rate of solubility of a given implant. While any biomaterial will

degrade over time, the amount of degradation equates to the amount of ionic release to the host.

There are many studies that have been conducted on the biocompatibility of metallic implants

and the key areas that are studied are solubility performance with an emphasis on fatigue life and

stress induced corrosion crack propagation. It is also desirable to have an implanted device

mimic the properties of the surrounding intracellular tissue such that a natural adaptation occurs

while in vivo for the life of the implant and the patient.

2.2 Nitinol phase transformation

The crystalline behavior of NiTi is what gives the material its physical mechanical

behavior. The unique characteristic of NiTi is having two solid phases of martensite and

austenite. At lower temperatures, NiTi is in a martensitic phase and at elevated temperatures, the

crystalline structure is in the austenitic phase. The transformation of these two solid phases

occurs from the twinning and detwinning of the martensitic and austenitic crystalline lattice. The

schematic shown in Fig. 2.1 illustrates the detwinning process of the martensite to austenite

transformation during temperature cycling under tension. The microstructure of the material

determines the mechanical behavior of the material and for this reason it is important to

Page 21: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

7

understand the crystalline lattice network to predict the deformation of a polycrystalline solid as

a whole.

Fig. 2.2 Transformation and detwinning processes during thermal cycling under tension [3]

The phase transformation from austenite to martensite is a function of both stress and

temperature as previously discussed. Similarly, NiTi has material properties that determine the

start and finishing temperatures of the austenite to martensite phase transformation, which are

dependent on the composition of the binary alloy. In most applications, the design parameters are

dominated by the temperature of the environment and the loading condition on the material. One

of the hindrances of developing a constitutive for NiTi is the tight tolerance of mechanical

behavior with slight changes to the composition. Moreover, slight changes in composition alter

the range of martensite to austenite phase transformations and one problem in particular that

designers have to mitigate is the presence of what is referred to as an R-phase that occurs under

Page 22: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

8

certain temperatures and stress loads. The martensite that is responsible for the shape memory is

not the same as the martensite that appears in the R-phase. The crystalline martensite that is

responsible for shape memory is a monoclinic cubic type of geometry and not the rhombohedral

shaped structure. The phase transformation of austenite to martensite that corresponds to

temperature, stress, and strain values as observed in Fig. 2.3. The phase transformation of

austenite to martensite allows for the ability of shape memory and superelasticity; however, the

R-phase that occurs with particular temperature ranges often acts as a hindrance for

characterizing superelastic properties and especially shape memory performance. The R-phase is

worthy of studying on the premise that the probability of R-Nitinol is superior to the fatigue

resistance of NiTi without the occurring R-phase. It was found by Lin et al that the probability of

fracture for overall range of strain for R-Nitinol was found to be lower than that for NiTi [4].

Fig. 2.3 Phase transformation corresponding to stress, strain, and temperature [5]

Page 23: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

9

The phase transformation that occurs in NiTi is dependent on the start and finish thermal

transitions of the austenite and martensite crystalline phases, as seen in Fig. 2.3. An important

characteristic of NiTi, is the nonlinear relationship between transformation strain and stress. The

theoretical basis of the Clausius-Clapeyron model describes the critical stress and temperature

for stress induced martensite transformation and implies a linear relationship between stress and

phase transformation. However, this concept doesn’t hold true for shape memory alloys [6]. One

of the key aspects of the martensitic transformation is the finishing process of the material

although it should be noted that any slight variations in the NiTi binary composition have a

significant impact on the mechanical behavior of the material.

There is some importance of understanding some of the basic crystallographic

configurations when characterizing phase transformations of NiTi. The B2 orientation refers to

the parent austenite phase and the B19 orientation refers to the martensite phase of NiTi. When

NiTi undergoes cooling, some grades of NiTi will transform from a high-temperature austenite

phase to martensite through an intermediate R-phase that competes with the B19 martensite

phase. Fig. 2.4 illustrates the parent austenite phase that is cubic shaped and when cooling

occurs, the lattice elongates along one of the existing diagonals. This configuration reduces the

cube angle and produces a rhombohedral structure. For the R-phase component to occur, the

martensite transformation must be suppressed relative to the creation of the R-phase.

Page 24: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

10

Fig. 2.4 Lattice change during the evolution of the R-phase transformation [7]

When NiTi undergoes the cooling process, there is a single stage transformation from an

austenite phase to a martensite phase; however, the phase transformation may also transform

from the austenite phase to the R-phase and onto the martensite phase causing a two stage

transformation process. Heat treatment is one of the important parameters in causing

transformation and thermo-mechanical characteristics of NiTi [8]. In order to accurately predict

the mechanical behavior of NiTi, one must have a full understanding of these particular

mechanical characteristics. An example of this discussion may be observed in Fig. 2.5 where

differential scanning calorimetry (DSC) results may be observed of both an as-received and a

heat treated sample at 700°C where the composition of the sample is SMA 54.5Ni-45.5Ti.

The as-received sample shown is from a heated state to cooling where two peaks appear

from the austenite phase to an R-phase followed by a final martensite phase appear. Similarly,

during a heating input from a cooled state, a trend develops where a martensite phase to an

austenite phase change occurs at increasing temperatures. This is an important characteristic to

note in regard to temperatures where desired phase change occurs. Hence, heat treatments are

crucial in designing a NiTi alloy where the presence of the R-phase plays a role in the desired

Page 25: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

11

results of the intended application [9]. It suffices to say that the stress-strain behavior of NiTi is

controlled by the microstructural constituents such as the R-phase and martensite [10].

Fig 2.5 Varying heat treatment times of NiTi in the case of cooling (left) and heating (right) [8]

2.3 Nitinol mechanical properties

2.3.1 Stress-strain characteristics

The stress-strain characteristics of NiTi are contributed from the austenite and martensite

phase transformation under varying loading conditions whether it is thermal or mechanical

energy. The martensitic transformation that occurs with NiTi is a solid-solid diffusionless

transformation [11]. It has been shown that martensite forms from austenite when cooled below a

certain temperature; however, the formation of martensite is also stress-induced. Fig. 2.6

illustrates the stress-strain characteristics of NiTi and the martensite transformation.

Page 26: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

12

Fig. 2.6 Martensite transformation with induced stress and strain [7]

Fig. 2.7 illustrates the tensile stress-strain responses of the NiTi alloy during fatigue

loading with max stresses of 300MPa and 500MPa with low-cycle fatigue (LCF) testing. An

interesting thing occurs after about 10 cycles where stabilization occurs. It may also be observed

by the formation of the hysteresis loops that after the onset of stabilization, a dissipation of

mechanical energy arises. This is caused by a frictional resistance of grain boundaries during

martensite formation. The volume density of the lost energy in a loading/unloading cycle can be

computed from the area within the hysteresis loop on the stress-strain curve [12].

Page 27: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

13

Fig. 2.7 Tensile stress-strain response of a NiTi alloy with cyclical LCF [13]

With NiTi alloys there is an interesting occurrence with stress and strain since there is both

superelasticity and shape memory involved. Hence, it is of importance to evaluate characteristics

both qualitatively and quantitatively. Nayan et al investigated several of the trends that

correspond to varying parameters of stress and strain with regard to the hysteresis behavior

during cyclic loading. The width of the hysteresis loop from loading and unloading is the energy

density dissipated during each cycle, whereas the area under the unloading part of the stress-

strain curve corresponds to the recoverable energy. Fig. 2.8 illustrates the characteristic trend of

hysteresis loops for a NiTi alloy cyclically loaded and unloaded. Moreover, a number of

martensite variants are present within the alloys and after cycling there is a reduction in the

number of moving boundaries. It is a noticeable trend that the width of the hysteresis loops

decrease with increasing cycles and this implies that the martensite damping capacity decreases

with increasing cycles. Another characteristic that was noted by the author was that the volume

Page 28: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

14

fraction of detwinned martensite increases and the proportional energy loss of the dewinned

martensite is half of the twinned martensite [13].

Fig. 2.8 a) Hysteresis width a) and area b) with varying stress [13]

Porous NiTi is of interest for some applications with particular emphasis on biomedical

applications where it is desired to have a surface area where cellular tissue has the ability to

attach and thrive during the life of the implant. It is desirable to have porosity with most

biomedical applications such that cellular adhesion prevents the implant from migrating. Micro

pores along the surface also act as fluid reservoirs and help lubricate surface interaction between

mating surfaces. There are some applications where a higher percentage of porosity is desired

and some applications where porosity is best kept at a minimum. Entchev et al conducted an

experiment to determine the stress-strain behavior of varying porosity as seen in Fig. 2.9 [14]. As

one would expect, a decreasing elastic modulus occurs with increasing porosity. Similarly, with

increasing porosity a decreasing damping capacity becomes apparent.

(a) (b)

Page 29: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

15

Fig. 2.9 Stress-strain behavior of NiTi with varying porosity [14]

2.3.2 Superelastic behavior of Nitinol

The superelasticity (pseudo-elasticity) of NiTi has varying parameters that determine the

mechanical behavior of the material. Any slight modifications to the nearly equiatomic

composition of NiTi alters the mechanical behavior of the material significantly. The finishing

process of the manufactured material also plays a vital role in the mechanical behavior as well as

and heat treatments or cold work performed on the material. The elastic modulus brings forth a

great deal of confusion when applied to NiTi alloys. The elastic modulus is difficult to define

with shape memory alloys and in particularly NiTi because the modulus varies with temperature

and typically cannot be assumed to be constant as it is with conventional metals and alloys. The

temperature dependence of the modulus of NiTi is well known while still challenging to design

engineers [15]. Hence, the challenge would be predominantly controlled by the sensitivity of the

Page 30: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

16

temperature or stress induced phase transformation, which determines both the superelastic and

shape memory effects.

One of the important mechanical properties of superelastic materials is that they exhibit

constant unloading stresses over large strains. Hence, the force applied by a superelastic material

is induced by temperature and not strain as other conventional materials. The advantage of this

characteristic involving medical device implants is that body temperature is constant and one can

design a device that applies constant stress over a wide range of shapes [16]. The superelasticity

and temperature dependence of NiTi play an important role in the ability to fine tune biologically

artificial devices.

2.4 Biocompatibility of Nitinol

In order for a material to be considered biocompatible, the material must induce little to

no immune response or the dissolution metal ions while in vivo. Some of the common

parameters that are quantitatively analyzed are corrosion properties, the release of metallic ions,

physical reactions with cellular tissues, and surface interaction with the imposed biological

surface and the implant surface. Similarly, biomaterials are tested in both vitro and in vivo with

the requirements of no toxic, allergenic, or carcinogenic reactions while in vivo for the life of the

patient with a respectable safety factor [17].

Another important characteristic of a potential biomaterial is the surface interaction of the

material and the intracellular tissue. If the implant device does not attach properly and adhere to

tissue, an adverse reaction may occur. The dominant parameter in cell adhesion is the wettability

or hydrophilic nature of the surface. A hydrophilic surface refers to the ability for a surface to

Page 31: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

17

have affinity with water or rather the friendly acceptance of molecular bonding. NiTi has a

hydrophilic surface and this also improves as the material is treated and sterilized prior to

insertion of the recipient. One particular study by Shabalovskaya et al indicated that sterilized

surfaces and contact angle has been shown to increase wettability by a factor of three [18]. On a

similar topic relative to adhesion, there also exists optimal pore size on a given implantation

surfaces. According to Itin et al, an optimal pore size is in the range of 100-500µm for osteoblast

cellular growth and surface porosity smaller than 100µm for connective fibroblast cells [19].

Similarly, smooth surfaces with porosity are beneficial such that the small porous cavities act as

fluid reservoirs, which are beneficial for wettability, connective tissue adhesion, and studies

indicate the fatigue life of the material increases respectively [20].

Nickel dissolution is inevitable with a nickel rich biomaterial such as NiTi although it

should be introduced to the body in small amounts. Excessive exposure to nickel concentrations

can lead to asthma, cellular hypersensitivity, cytotoxicity, and genotoxicity. Porous surfaces are

generally desired in medical applications where cellular genesis is desirable such that the implant

does not migrate to undesired locations. However, nickel release is increased due to enhanced

surface exposure where the surface of the material has little to no cold work treatments, which

decrease metallic dissolution due to surface compaction and compressive residual stresses.

NiTi is an excellent candidate for biomedical applications and for this reason many

biomedical applications have been developed over the last ten years. Before the introduction of

NiTi, most biomedical implantations were stainless steel (FeC) and cobalt-chromium (CoCr);

however, with advances in technology, Nitnol has made its presence known to the scientific

community with promising outcomes. Since NiTi has a shape memory effect and has

Page 32: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

18

temperature dependence on hysteresis characteristics, there are similarities to biological tissues

and thus are mimetic to the kinesiology and biomechanics of humans and other biological

specimens. The possibilities of NiTi seem almost endless with the possibilities for design

considerations for implantation devices. Some of the early clinical utilization of NiTi includes

wire for orthodontic tooth alignment, osteosynthesis staples, vena cava filters. Developments in

NiTi for biomedical applications have evolved tremendously in the last 10 years. There have

been a number of studies involving biocompatibility of NiTi since early developments of NiTi

addressed concerns in the regard of nickel dissolution while in vivo. The biocompatibility of

metals, amongst other factors, relates to the corrosion properties of the metal and chemical

interactions between the host and the imposed metallic implantation device. Studies reflect that

NiTi exhibits excellent corrosion resistance while in vivo. However, this does not exclude

metallic ion release. The rate of this release, the solubility and protein-binding capacity of the

ions and their cytotoxic, allergenic and genotoxic activity will finally determine the biological

safety. Based on these grounds, all these aspects of biocompatibility should be taken into account

before the NiTi alloy can be safely used as an implant in the human body [21].

However, it has been shown in a number of studies that NiTi is biocompatible in the

regard of dissolution of nickel ions. NiTi has good biocompatibility with human osteoblasts and

fibroblasts. It is important to note that larger concentrations of nickel ions are introduced to the

host in the first few days of implantation. Literature indicates that conclusions seem to be

unanimous on the biocompatibility of NiTi. Ryhanen et al reported that NiTi releases more

nickel in cell culture media in the first two days but after concentration levels decrease [22].

Moreover, the amount of dissolved nickel was observed to be minimal such that no toxic effects

Page 33: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

19

or decrease in cell proliferation was found. In another study by Pertile et al it was observed that

the release of Ni ions while in vivo was negligible and it was suggested that the release of Ni

ions may even be lower than the average dietary ingestion of this element. It was also mentioned

that the premature failure of metallic implants usually starts with the breakdown of the TiO2 layer

in similarity to corrosion locations that are inherent to the initiation of cracks and fractures [23].

It was reported in another study conducted by Kapanen et al that NiTi exhibits low cytotoxicity

in contact with bone cell formations where stainless steel was not equally tolerable as NiTi [24].

NiTi has been proven as a stable biomaterial as literature would suggest. There is a great deal of

research and supporting literature that substantiate the biocompatibility of NiTi. The TiO2 layer

on the surface of NiTi is the primary factor in the biocompatibility of the material and with

proper treatment of the material there is no concern for nickel dissolution.

2.5 Fatigue life of Nitinol

Numerous investigators have analyzed the cyclic failure of NiTi alloys for different

specimen shapes such as bars, wires, and plates. Typically NiTi performs well in a strain or

displacement controlled fatigue but does not perform well in a stress controlled fatigue

environment [25]. Identifying a safe operating range is important for NiTi medical implants

exposed to high cycle fatigue conditions. In such a case, Soderberg or Goodman plots are known

to drastically over estimate the safe operating range of safe strain level in nickel-titanium based

alloys [26].

The number of cycles of failure plotted against the stress amplitude for martensitic and

austenitic NiTi alloy may be observed in Fig. 2.10. It is suggested by Nayan et al that a NiTi

Page 34: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

20

alloy in an austenite phase has a lower threshold to stress at higher stress amplitudes in

comparison to a NiTi alloy in a martensite phase. However, at lower stress amplitudes it is

suggested that austenite has a higher threshold to stress. It was noted that the stress required for

the onset of non-linear deformation (detwinning stress in the case of martensite and the stress

required for inducing austeite to martensite transformation in the case for the austenite) is less

than the martensitic alloy in comparison to the austenitic alloy. It was also noted by the author of

this study that a possible factor in the cause of lower fatigue resistance of the austenitic alloy is

the stabilization of the stress induced martensite (SIM) during fatigue loading or that the

microstructure is more tolerant and softer for fatigue induced damage propagation and failure

[13].

Fig. 2.10 Stress amplitude vs. cycles for an austenitic and martensitic NiTi alloy [13]

An important characteristic about the stress-life of NiTi alloys is hysteresis under a given

load condition. Preliminary experimental results can be used to predict where failure may occur

Page 35: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

21

or the onset of plastic flow. Especially in shape memory applications, the dissipation of

mechanical energy directly correlates to the shape memory effect and a prediction of that

particular threshold would be a useful tool for a material model. The cyclic behavior of

hysteresis is a useful resource such that the dissipation of mechanical energy may be

characterized in many fashions whether hardening or softening occurs over the life of intended

application. Clayton et al suggests there is a rather unique indifference that exists for a given

stress amplitude between a pearlite steel and a NiTi alloy. It is apparent that NiTi absorbs much

more of the strain energy in a short number of cycles in comparison. Moreover, this would imply

that NiTi absorbs strain energy as well as strain hardens during the course of cyclical stress

inputs [27].

Fig. 2.11 Hysteresis loops for a) pearlitic steel and a b) 55- NiTi alloy [27]

Page 36: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

22

Conventional metals and alloys have S-N curves that are used to evaluate the life of a

design model. The stress-strain behavior has little deviation and therefore mechanical properties

may be ascertained to be constant with each batch. However, NiTi is dissimilar in this fashion

such that small changes in composition and heat treatment histories result in large deviations of

mechanical properties. Hence, designers and engineers must individually evaluate each product,

material, and set of process parameters in order to provide accurate fatigue life data [28]. The

metallurgical properties such as grain boundaries, precipitates, oxide layers, and cooling methods

predict the characteristics of shape memory alloys just as conventional metals are characterized.

Shape memory alloys have the ability to be trained by stress induction or by thermal histories

applied directly to the material. These loading paths determine the permanent set of the material

and/or cold working abilities of the material as well. Similarly, the martensitic phase of a shape

memory alloy exhibits a hardness and wear resistance that is influenced by the ease or difficulty

for retransforming and/or reorienting of existing martensite plates. The behavior exhibited by

this transformation if characterized by the length of martensite plates, which are conditioned

mainly by the precipitate size and precipitate-free zones. Moreover, the smaller scales of

martensite plates have a higher mobility rate thus improving the energy absorption and reducing

wear damage. A great quantity of these smaller scale martensite plates creates a stress field

impeding the ease of martensite plate mobility resulting in decreased wear capabilities. It was

confirmed by Arciniegas et al that the existence of precipitates contributes to the nucleation of

martesnite plates but also slows the rate of their growth [29].

Page 37: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

23

2.6 Crack growth behavior

It is important to evaluate fatigue life when each of the common phases are present to

efficiently characterize a pattern of failure as mentioned in the last section. The initiation of

cracks and crack growth are resulting parameters of fatigue studies. Pelton et al referred to past

research suggesting that the fatigue process is generally categorized into five stages: early

microstructural damage, micro-crack nucleation, short-crack propagation, macro-crack

propagation, and final crack fracture. It was noted by Pelton et al that stress based fatigue

analyses are preferred in the presence of microscopic surface flaws or existing cracks that create

stress concentrations. When a critical flaw length is exceeded, the use of stress based mechanics

provides a method of quantifying fatigue and fracture behavior [30].

It is important to efficiently characterize crack growth behavior with various in vitro

studies such that a particular biomedical application can be validated. In the presence of a

corrosive environment, fatigue crack growth rates per cycle in most metallic materials are

actually accelerated by lower frequencies due to an increased time period for the corrosion

kinetics to be active. The implications of this are that life predictions may not be conservative

when based on higher-frequency fatigue data [31]. In a study conducted by Robertson et al, there

was comparison to crack growth rate and stress intensity with the use of a NiTi tube at a load

ratio of R=0.5 but in different mediums, see Fig. 2.12. The efforts were to characterize cracking

modes in relation to corrosion. It was also noted by the authors that the vast majority of fatigue

data for NiTi alloys have been tested at frequencies of 30 Hz or more, primarily for reasons of

expediency. This correlation suggests lower frequencies more accurately represent in vivo

conditions and produce marginally slower crack-growth rates than at higher frequencies, which

Page 38: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

24

indicate that higher frequency tests that are utilized provide a more conservative lifetime

prediction for NiTi biomedical devices.

Fig. 2.12 Crack growth of a NiTi tube (45° orientation) at R=0.5 at various conditions [31]

Crack growth behavior of NiTi while in compression may be observed in Fig. 2.13 where

tensile compressive stresses are retained and this is believed to be the cause of the crack

extension upon releasing the elastic strain energy of a severely bent NiTi wire. It was noted in

the study conducted by James et al that fractures occurring during compression generally occur

when loading is reversed where at the arch of the bending location experiences small tensile

loads. These particular fractures are typically caused by voids in the material that tend to

concentrate in a particular region resulting in stress concentrations [32].

Page 39: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

25

Fig. 2.13 Crack growth of a NiTi wire after severe compression [32]

The phase transformation and stress behavior of a NiTi alloy is best observed with a

notched specimen. The highest stressed region is in closest proximity of where the notch is and

this is where martensitic bands develop and small amounts of plastic residual strains accumulate.

The region outside of the highest stressed region will undergo a phase transformation from

austenite to martensite where the remainder of the specimen will be in an elastic state. Daly et al

conducted a study emphasizing on stress behavior of notched specimens, which may be observed

in Fig. 2.14. The Figure details a mode I crack that characterizes the stress field of a notched

NiTi specimen. The stress behavior of NiTi is important to have understanding of such that NiTi

devices are properly designed in regard to geometry as well as various loading conditions.

Page 40: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

26

Fig. 2.14 Crack behavior of a notched NiTi sheet [33]

2.7 Issues and future research of Nitinol

There are some issues that are of concern with regard to NiTi such as surface

modification in relation to superelastic behavior. This would also be questionable with relation to

the thickness of the work piece. Most of the studies relative to stress-strain behavior of NiTi or

investigated in modes of tension and there is little research and literature for NiTi in compressive

modes. Surface modification methods such as laser shock peening, shot peening, and low

plasticity burnishing induce compressive stress into a given work piece. Further understanding of

compressive stress-strain behavior would be resourceful for many applications of NiTi. The

thermal sensitivity of NiTi brings many challenges for designing medical devices. It is of great

importance that proper heat treating of the material is done such that phase change is direct from

austenite to martensite without interference in the lattice. Another issue arises when considering

the fatigue life of Nitinol such that the frequency and amplitude of the given application be

Page 41: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

27

compared to data that is relative. While Nitinol continues to be on the forefront as an excellent

biomaterial, due to the elegance of the mechanical properties, it is also of importance to have full

understanding of the conditions that the material will be subjected to as well as the effect of

surface modification and mechanical properties.

Page 42: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

28

References

(1) Yang J., Wang J., and Tong S., Surface Properties of Bio-Implant Nitinol Modified by

ECR Cold Plasma, Materials Science and Technology, Vol. 20, 2004, pp.1427-1430.

(2) Morgan N.B., Medical Shape Memory Alloy Applications – The Market and its Products,

Materials Science and Engineering, Vol. 378, 2004, pp. 16-23.

(3) Huseyin S., Hamilton R., Canadinc D., Zhang X.Y., Gall K., Karaman I., Chumlyakov Y.,

and Maier H.J., Detwinning in NiTi Alloys, Metallurgical and Materials Transactions, Vol.

34, 2003, pp. 5-13.

(4) Lin Z., Wong S., Tahran A., Fatigue Study On R-Nitinol Vs. Nitinol Using Rotating Beam

Fatigue Tester, Proceedings of the International Conference on Shape: Memory and

Superelastic Technologies, 2008, pp. 167-174.

(5) Patoor E., Lagoudas C., Pavlin E., Brinson C., Gao X., Shape Memory Alloys, Part I:

General Properties And Modeling of Single Crystals, Mechanics of Materials, Vol. 38,

2006, pp. 391-429.

(6) Wu X.D., Sun G.J., Wu J.S.,The Nonlinear Relationship Between Transformation Strain

and Applied Stress for Nitinol, Materials Letters, Vol. 57, 2002, pp. 1334-1338.

(7) Eaton-Evans J., Dulieu J.M., Little E.G., Brown I.A., Observations During Mechanical

Testing of Nitinol, Mechanical Engineering Science, Vol. 222, 2007, pp 97-105.

(8) Yoon S., Yeo D., Phase Transformations of Nitinol Shape Memory Alloy By Varying With

Annealing Heat Treatment Conditions, Smart Materials III, Vol. 5648, 2005, pp. 208-215

(9) Lin B., Gall K., Maier H., Waldron R., Structure And Thermomechanical Behavior of

NiTiPt Shape Memory Alloy Wires, Acta Biomaterialia, Vol. 5, 2009, pp. 257-267.

(10) Lach C., Turner, Taminger K., Shenoy, Effects of Thermomechanical History on the

Tensile Behavior of Nitinol Ribbon, Proceedings if SPIE-the International Society for

Optical Engineering, Vol.4699, 2002, pp. 323-334.

(11) Zhang W., Hackl K., Hoppe U., Micro-Mechanical Modeling of the Constituitive Behavior

of NiTi Shape Memory Alloys, Proceedings in Applied Mathematics and Mechanics, Vol.

4, 2004, pp. 272-273.

Page 43: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

29

(12) Chen W., Wu Q., Kang J., Winfree N., Compressive Superelastic Behavior of a NiTi Shape

Memory Alloy At Strain Rates of 0.001-750s-1

, International Journal of Solids and

Structures, Vol. 3, 2001, pp. 8989-8998.

(13) Nayan N., Buravalla V., Ramamurty U., Effect of Mechanical Cycling On The Stress-

Strain Response of A Martensitic Nitinol Shape Memory Alloy, Materials Science and

Engineering, Vol. 525, 2009, pp. 60-67.

(14) Entchev P., Lagoudas D., Modeling Porous Shape Memory Alloys Using Micromechanical

Averaging Techniques, Mechanics of Materials, Vol. 34, 2002, pp. 1-24.

(15) Duerig T.W., Some Unsolved Aspects of Nitinol, Materials Science and Engineering, Vol.

438-440, 2005, pp. 69-74.

(16) Duerig T., Pelton A., Stoeckel D., An Overview of Nitinol Medical Applications, Materials

Science and Engineering A, Vol. 273-275, 1999, pp. 149-160.

(17) Widu F., Drescher D., Junker R., Bourauel C., Corrosion and Biocompatibility of

Orthodontic Wires, Journal of Materials Science: Materials In Medicine, Vol. 10, 1999, pp.

275-281.

(18) Shabalovskaya S., Ryhanen J., Yahia L., Bioperformance of Nitinol: Surface Tendencies,

Materials Science Forum, Vol. 394-395, 2002, pp. 131-138.

(19) Itin V., Gyunter V., Shabalovskaya S., Sachdeva L., Mechanical Properties And Shape

Memory of Porous Nitinol, Materials Characterization, Vol. 32, 1994, pp. 179-187.

(20) Lin Z., Denison A., Nitinol Fatigue Resistance – A Strong Function of Surface Quality,

Medical Device Materials - Proceedings of the Materials and Processes for Medical

Devices Conference, 2003, pp. 205-208.

(21) Wever D.J., Veldhuizen A.G., Sanders M.M., Schakenraad J.M., Van Horn J.R., Cytotoxic,

Allergenic and Genotoxic Activity of a Nickel-Titanium Alloy, Biomaterials, Vol. 18,

1997, pp. 1115-1120.

(22) Ryhanen J., Niemi W., Serlo E., Niemela P., Sandvik H., Pernu T., Salo T.,

Biocompatibility of Nickel-Titanium Shape Memory Metal and its Corrosion Behavior in

Human Cell Cultures, Journal of Biomedical Materials Research, Vol. 35, 1996, pp. 451-

457.

(23) Pertile L., Silva O., Peccin V., Peres R., Silveira P., Giacomelli C., Giacomelli F., Fredel

M., Spinelli A., In Vivo Human Electrochemical Properties of a NiTi-Based Alloy

(Nitinol) Used for Minimally Invasive Implants, Journal of Biomedical Materials Research

Part A, Vol. 89A, No. 4, 2008, pp. 1072-1078.

Page 44: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

30

(24) Kapanen A., Ryhanen J., Danilov A., Tuukkanen J., Effect of Nickel-Titanium Shape

Memory Metal Alloy On Bone Formation, Journal of Biomaterials, Vol. 22, 2001, pp.

2475-2480.

(25) Perry K., Labossiere P., Phase Transformations In Nitinol And Challenges For Numerical

Modeling, In Medical Device Materials II, ASM International, 2004, pp. 131–134.

(26) Walak S., Boston Scientific Corporation, Tension-Tension Fatigue Testing of Nitinol Wire,

International Conference on Shape Memory and Superelastic Technologies, 2006, pp. 27-

34.

(27) Clayton P., Tribological Behavior of A Titanium-Nickel Alloy, Wear, Vol.162-164, 1993,

pp. 202-210.

(28) Norwich D., Fasching A., A Study of The Effect of Diameter On The Fatigue Properties of

NiTi Wire, Journal of Materials Engineering and Performance, Vol. 18, No 5-6, 2009, pp.

558-562.

(29) Arciniegas M., Casals J., Manero J., Pena J., Gil F.k Study of Hardness and Wear

Behaviour of NiTi Shape Memory Alloys, Vol. 460, 2008, pp. 213-219.

(30) Pelton A., Schroeder V., Mitchell M., Gong X., Barney M., Robertson S., Fatigue and

Durability of Nitinol Stents, Journal of the Mechanical Behavior of Biomedical Materials,

Vol I, 2008, pp. 153-164.

(31) Robertson S.W., Ritchie R.O., In Vitro Fatigue-Crack Growth and Fracture Toughness

Behavior of Thin-Walled Superelastic Nitinol Tude for Endovascular Stents: A Basis for

Defining the Effects of Crack-Like Defects, Journal of Biomaterials, Vol 28, 2006, pp.

700-709.

(32) James B., Foulds J., Eiselstein L., Failure Analysis of NiTi Wires Used In Medical

Applications, Journal of Failure Analysis And Prevention, Vol. 5, No. 5, 2005, pp. 82-87.

(33) Daly S., Miller A., Ravichandran G., Bhattacharya K., An Experimental Investigation of

Crack Initiation In Thin Sheets of Nitinol, Acta Materialia, Vol. 55, 2007, pp. 6322-6330.

Page 45: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

31

CHAPTER 3

CHARACTERIZATION OF MICROSTRUCTURE AND DYNAMIC MECHANICAL

PROPERTIES OF A BIOMEDICAL NITINOL ALLOY

Abstract

Nitinol, an equiatomic alloy of nickel and titanium, has broad applications in the

biomedical industry. It is widely accepted that Nitinol (NiTi) is very biocompatible in the human

body. It has been used mainly as a material for various kinds of stents. Much information exists

for the mechanical response of NiTi that has been loaded in tension, but little exists for NiTi in

compression. Furthermore, even less information is available for the compressive mechanical

response of NiTi under increasing strain rates. This study details the compressive mechanical

response of SE508 NiTi (50.8at.%Ni-49.2 at.%Ti) under both quasi-static compression and Split

Hopkinson pressure bar testing. Under quasi-static loading conditions, the elastic moduli in the

austenite and martensite regions were found to be 48 GPa and 41 GPa respectively. The ultimate

compressive strength (UCS) was found to be 2.3 GPa. The SHPB data showed a general trend of

decreasing the UCS while increasing the toughness with increased strain rate. The average grain

size of the undeformed NiTi samples was on the order of 30 microns.

Page 46: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

32

3.1 Introduction

Nitinol is a nickel-titanium alloy of near equiatomic composition with shape memory and

superelastic mechanical properties and is known to have elastic strains of up to 8%. Slight

variations in the binary alloy composition change the mechanical properties significantly;

moreover, heat treatment history and finishing of the material play a vital role in the mechanical

properties as well. Typically, superelasticity occurs at elevated temperatures that approach the

melting point of the material. NiTi is composed of nickel and titanium and the accompanying

characteristics of both metals distinguish overall properties of a superalloy yet NiTi has

superelastic features well below the melting point. As a result, these material properties are

advantageous to various biomedical and aerospace applications. NiTi was first discovered in the

early 1960’s and some of the first experimentations were conducted by the Naval Ordinance

Laboratory. The term Ni-Ti-Nol was brought about by the composition of this nickel-titanium

binary alloy and the development of the material conducted by the Naval Ordinance Laboratory.

The public introduction of NiTi was brought about in 1968 and thereafter a series of devices

were patented in the regard of using the mechanical energy from NiTi [12]. An example of one

of the many early developments of NiTi devices may be seen in Figure 3.1.

Page 47: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

33

Fig. 3.1 Thermobile engine patent [12]

The mechanical properties of NiTi bring forth a particular interest for many applications;

however, the mechanical properties of NiTi are sensitive to variations in composition due to the

solid phase presence of the material, see Figure 3.2. NiTi can be considered an ordered

intermetallic that has an extremely narrow composition range below the eutectoid in the phase

diagram [10]. NiTi is sensitive to changes in composition since the narrow region of the binary

alloy in solid phase is relatively small, which may be observed in the phase diagram of the binary

alloy. NiTi is typically manufactured by vacuum arc melting or vacuum induction melting.

Vacuum arc melting requires multiple remelts of the material to ensure sufficient homogeneity

while vacuum induction melting typically introduces oxygen contamination [13]. Since NiTi is

sensitive to variations in composition, it would suffice to measure the mechanical properties for

precision engineered applications and to ensure precise superelasticity and shape memory

characteristics. This study analyzes the dependence of strain rate with the stress-strain response

of superelastic (50.8 at.%Ni - 49.2 at.%Ti) NiTi. NiTi has a strong dependence of strain rate with

Page 48: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

34

the mechanical properties of NiTi [11] and this is characterized in this particular study.

Moreover, NiTi exhibits exceptional mechanical behavior that is attractive to biomedical

applications since it has superior elastic properties. Similarly, the shape memory capabilities of

NiTi are highly attractive to the aerospace industry and the technical communities abroad for

various applications. Moreover, NiTi has similar mechanics to biological tissue with numerous

studies supporting excellent biocompatibility properties. Similarly, biocompatible NiTi has a

unique elastic regime with recoverable strains of up to 8.0%. The effect of NiTi in compression

and tension are known to have an asymmetric stress-strain response where most studies focus on

the tensile properties of NiTi. One of the motivations of this experimental work is to determine

how superelastic (50.8 at.%Ni - 49.2 at.%Ti) NiTi responds to various strain rates while under

compressive loading conditions at room temperature. Quasi-static and dynamic compression

tests are conducted in this study in order to characterize an overall range of how this material

behaves at both low and high strain rates.

Page 49: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

35

Fig. 3.2 Phase diagram of a nickel-titanium binary alloy [13]

3.2 NiTi SE508 fabrication and sample preparation

3.2.1 Material fabrication

The NiTi composition used in this study was 50.8at.%Ni-49.2 at.%Ti and was acquired

from NiTi Devices and Components (NDC). This specific composition was chosen for testing

because it is commonly used in medical devices such as stents. The material exhibits superelastic

properties at room temperature and so it is ideal for this task. This particular material was created

from a solid ingot manufactured by vacuum induction melting that was then drawn to produce

bar stock. The unaltered bar stock acquired from NDC had nominal dimensions of 0.5” in

diameter and 2.6” in length. To achieve superelastic properties at room temperature, the material

was heat treated by NDC in a salt bath at 505˚C for 45 seconds.

Page 50: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

36

3.2.2 Sample preparation

The cylindrical bars obtained from NDC were reduced in diameter and sectioned by

turning to create twenty-one 0.25” x 0.25” samples. Machining was done relatively slowly at

roughly 400 RPM with a depth of cut of 0.0070 inch with lubrication to avoid thermal damage as

this could alter the microstructure of the material and in turn change its mechanical properties.

Sample sizes were chosen for SHPB testing because the literature suggests that radius and

diameter should be kept at ratios between 0.5-1.0. These dimensions were also used for quasi-

static testing, as they were also appropriate. After machining, the samples were then numbered

on the sides and edges with a permanent marker.

3.3 Experimental procedures

3.3.1 Quasi-static compression testing

Quasi-static compression testing consists of compressing a sample between two large

plates. During testing, displacement and compressive load are recorded by the testing equipment.

From the resulting data compressive mechanical properties such as yield strength, ultimate

strength and young’s modulus are derived. This allows complete compressive mechanical

characterization of the material at strain rates low enough to be considered negligible. In these

experiments, the strain rate chosen for testing was 0.001/s and testing was performed at room

temperature. Because of the hardness of this material, Silicon carbide disks were used to

compress the samples so as to not damage the test equipment. Also, a small amount of grease

was placed between the carbide disks and the ends of the samples to decrease the friction

Page 51: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

37

between the two during testing. Testing was conducted at the CAVS research facility at

Mississippi State University.

3.3.2 High strain rate Split-Hopkinson pressure bar testing procedure

In order to characterize the mechanical behavior of superelastic NiTi, a classical Split-

Hopkinson pressure bar test was implemented where dynamic strain measurements range from

2600s-1

to 6400s-1

. The SHPB (Split Hopkinson Pressure Bar) experimental test setup is also

referred to as the Kolsky apparatus and it is commonly used as a method to test the mechanical

properties of a given material at high strain rates [17]. During compressive SHPB testing, a short

cylindrical specimen is sandwiched between the ends of two bars where a striker bar is fired at

the free end of the incident bar, see Figure 3.3 [5]. Upon the impact of the striker bar, a stress

wave is initiated that travels along the first bar (incident) and into the specimen. Due to the

impedance mismatch between the bars and the specimen, a part of the wave is reflected back

along the incident bar from the transmitter bar. The rest of the incident wave travels through the

specimen and enters the second bar (Transmitter) [14].

Page 52: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

38

Fig. 3.3 Schematic of the SHPB test setup [5]

It has been noted in literature that the stress uniformity during plastic flow is more aptly

characterized by the uniformity of the specimen at the beginning of a test when the applied stress

is relatively small. Hence, uniform stress flow should be validated during the elastic response of

a given test [3]. Moreover, to fully define the elastic and plastic behavior of a material, the point

of fracture must be established or the stress-strain behavior will be not fully developed.

Furthermore, the geometry of the specimen is chosen such that stress uniformity is constant

throughout the specimen during impact. A cylindrical specimen with a height of 0.25” and a

length of 0.25” was selected for this experiment, see Figure 3.4. The frictional coefficient

between the incident bar, transmitter bar, and the specimen are critical parameters in the

accuracy of the SHPB test and the evaluation of one-dimensional wave propagation [4]. During

impact of the specimen, the diameter changes and interfacial friction comes into play as well as

the radial inertia effect. While there are corrective formulations to make these errors relatively

small [15], it would suffice to have a smooth lubricated surface contact between the specimen

Wheatstone

Bridge

Air

Gun

Striker bar Incident bar Transmission bar Stop block

Strain gage Strain gage

Pressure

source

Accumulator

Manual

valve

Release

valve

Digital Counter

Led’s

1x

2x

Signal conditioner

Data acquisition

Page 53: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

39

and the surface interface. In this particular test, a light coating of beeswax is applied between the

specimen and the interface of the incident bar and the transmitter bar. The application of

beeswax allows for both adhesion of the specimen to the pressure bars and for the reduction of

friction during impact by acting as a lubricant. It was noted in a past discussion by Davies and

Hunter that the omission of inertial terms is legitimate for thin specimens, however, the neglect

of interfacial frictional effects is not. In order to overcome the frictional problem, it is imperative

to introduce specimens with (length/diameter) aspect ratios of 1.0 [19]. Hence, a commonly

selected aspect ratio of 1.0 was selected in reference to this past discussion. Moreover, an

important parameter in the consideration of specimen geometry for the SHPB test is whether or

not the material is ductile or brittle. The inherent problem that is often encountered with brittle

materials is the uniformity of stress flow through the material. Many common materials of

interest such as rocks, concrete, and ceramics are brittle with strains less than 1.0% and

modifications to the SHPB test method must be made [16]. There are several dominate

parameters that affect the ductility of near equiatomic NiTi and that is the percentage of cold-

work, the reduction of area, heat treatments, and the amount of each element in the binary NiTi

composition. With all these considerations, the specimens used in the SHPB test are considered

to be of ductile nature.

Page 54: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

40

Fig. 3.4 a) Dimensions for SHPB sample; b) Shear plane during dynamic compression testing

3.4 Experimental results

3.4.1 Stress-strain curves

NiTi has been shown in literature to have a characteristic superelastic stress-strain curve

that consists of two segments of elasticity under normal quasi-static loading conditions [2].

However, very little information exists in the literature for stress-strain data of NiTi under

dynamic loading conditions at high strain rates under compression. This topic was covered to a

certain extent by Chen et al [1], but the strain rates tested were still rather low. Stress-Strain data

found in this experiment for both quasi-static and dynamic strain rates can be seen in Figure 3.5

below. The data gathered for the quasi-static samples showed a close relationship and was

averaged into a singular plot by adding stresses containing the same strain values and dividing

the result by two. The resulting graph of stress versus strain shows a similar result to that of the

a) b)

Page 55: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

41

literature of NiTi samples of the same composition and heat treatment. Looking at the data it can

be clearly seen that as the strain rate is increased to the point that it is no longer quasi-static that

the superelastic transition region tends to flatten out and become less pronounced, while the

ultimate compressive strength (UCS) becomes greater. However, when the strain rate is

increased past a certain point the UCS starts to lessen and the material gains toughness. The

strain rate at which this happens cannot be clearly determined by this study, because strain rate

data could not be obtained for strain rates less than 2600/s using the SHPB technique.

Fig. 3.5 Stress-strain data of SE508 NiTi for quasi-staic and dynamic strain rate testing

3.4.2 Microstructural characterization

There is some importance of understanding some of the basic crystallographic

configurations when characterizing phase transformations of NiTi. The B2 orientation refers to

the parent austenite phase and the B19 orientation refers to the martensite phase of NiTi. The

unique shape-memory and superelastic properties of NiTi are due to a diffusionless phase

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0.00 0.05 0.10 0.15 0.20 0.25

Tru

e S

tress (

GP

a)

True Strain (-)

0.001 2600 3157 3888 4680

Page 56: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

42

transformation between a parent austenite phase (B2 crystalline structure) and a martensite phase

(B19 crystalline structure). One of the important characteristics of NiTi is the temperature at

which austenite transforms to the martensite phase. These phase changes are commonly called

finishing temperatures at which increasing and decreasing temperatures are introduced to the

material. Figure 3.6 [18] illustrates the trends at which these phase transformations occur. The

austenite finishing temperature fA is the most important temperature since it dictates the

transition between shape memory and superelastic properties [10]. ThefA temperature can be

adjusted through thermo-mechanical treatments in order to optimize the performance of the

material for the intended application.

Fig. 3.6 Schematic of the transformation and detwinning processes [18]

When NiTi undergoes cooling, some grades of NiTi will transform from a high-

temperature austenite phase to martensite through an intermediate phase that competes with the

B19 martensite phase, which is known as the R-phase. Figure 3.7 illustrates the parent austenite

Page 57: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

43

phase that is cubic shaped and when cooling occurs, the lattice elongates along one of the

existing diagonals. This configuration reduces the cube angle and produces a rhombohedral

structure and thus referred to as the R-phase. For the R-phase component to occur, the martensite

transformation must be suppressed relative to the creation of the R-phase [9].

Fig. 3.7 The evolution of the R-phase transformation [9]

One of the unique facets of NiTi is developing a constitutive model since the nature of

the material has tight tolerances with slight changes to the composition [7]. Commercially used

NiTi is not widely distributed from a large number of vendors; however, batches will vary to

small degrees due to small variations in processing parameters and thus material constants must

be obtained to accurately characterize the mechanical behavior of the material. Hence, any

deviation from the equiatomic composition of NiTi requires that the alloy is in a two phase field

and these slight deviations affect the phase transition temperatures significantly [10]. The

interesting and unique phenomenon that occurs with shape memory alloys such as NiTi is the

phase transformation that occurs during loading conditions. Temperature is also a parameter that

is involved with the evolution of the phase transformation. The testing conditions regarding this

Page 58: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

44

study were kept constant at room temperature in order to isolate the mechanical stress-strain

response at a constant temperature.

The microstructural characteristics of NiTi in various conditions may be observed in Fig.

3.8. Two different etchants were used on polished NiTi samples to enhance the grain boundary

definitions.

Fig. 3.8 Optical images (50x magnification) of NiTi samples at various strain rates in

compression; (a) uncompressed, (b) 0.001 s-1

, (c) 2600s-1

, and (d) 3157s-1

The samples were polished to a mirror shine to improve the etchant process. The primary

objective of the etchant is to pronounce the grain boundaries of the NiTi samples used during this

experimental work. There was severe surface pitting with the use of etchant A, which was of

(c) (d)

(a) (b)

Page 59: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

45

composition 45% HNO3, 45% H20, and 10% HF by volume; the same result occurred regardless

of reactant time. An alternative etchant, etchant B, of composition: 10% HNO3, 85% H20, and

5% HF by volume [8]. While etchant B achieved the objective of pronouncing grain boundaries

such that grain size measurements could be made, a consequence of mild pitting resulted, see

Figure 3.9.

Fig. 3.9 uncompressed NiTi surface after etching with (a) etchant A, (b) etchant B

The pitting is most likely due to elemental trace impurities on the surface yet the mild

nature of the pitting was considered acceptable for the desired grain size distribution

measurements for each of the considered strain rates. The samples observed in Figure 3.8 range

from uncompressed, quasi-static, 2600s-1

, and 3157s-1

. A trend develops with respect to strain

rate and grain size distribution, Figure 3.10. As one would expect, the grain size decreases with

increasing strain rate. The measurements of the grain size distribution were taken along the

longitudinal axis of the material since normal loading was imposed respective to this direction.

The as-received drawn NiTi rod material exhibited an average grain size of ~40µm that is similar

(a) (b)

Page 60: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

46

to the findings in research articles regarding NiTi grain size. The nominal grain size distributions

were found to be ~34µm for the quasi-static (0.001s-1

) strain rate, ~32µm for the strain rate of

2600s-1

, and ~26µm for the strain rate of 3157s-1

.

Fig. 3.10 NiTi grain size distribution at various strain rates after compression testing

3.5 Conclusions

The mechanical properties of Nitinol (50.8at.%Ni-49.2 at.%Ti) have been obtained in

compression for both quasi-static and dynamic strain rates using compression and SHPB testing.

For the quasi-static loading condition, the elastic moduli in the austenite and martensite regions

were found to be 48.3 GPa and 41.0 GPa respectively. The UCS for the quasi-static condition

was found to be 2.3 GPa. The overall SHPB data showed a general trend of decreasing UCS

while increasing the toughness with increased strain rate. Increasing the strain rate also tended to

flatten out the transformation region between austenite and martensite. This region became

unrecognizable in the stress-strain response at the highest strain rates. Optical images of this

0

5

10

15

20

25

30

35

40

45

grai

n s

ize

(µm

)

Uncompressed 0.001s-1 2600s-1 3157s-1

Page 61: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

47

material showed a grain size on the order of 30 microns for the undeformed samples. Optical

images were also taken to show the evolution of the grain structure with increased strain rate.

Page 62: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

48

References

(1) Chen, W., Wu, Q., Kang, J., Winfree, N., Compressive superelastic behavior of a NiTi

shape memory alloy at strain rates of 0.001-750 s-1

, International Journal of Solids and

Structures, Vol. 38, 2001, pp. 8989-8998.

(2) McKelvey, A., Ritchie, R., Fatigue-crack propagation in Nitinol, a shape-memory and

superelastic endovascular stent material, 1999, pp. 301-307.

(3) Yang L.M., Shim V.P.W, An analysis of Stress Uniformity in Split Hopkinson Bar Test

Specimens, International Journal of Impact Engineering, Vol. 31, 2005, pp. 129-150.

(4) Meng H., Li Q.M., Correlation Between the Accuracy of a SHPB Test and the Stress

Uniformity Based on Numerical Experiments, International Journal of Impact

Engineering, Vol. 25, 2003, pp. 537-555.

(5) Lifshitz J.M., Leber H., Data Processing in the Split Hopkinson Pressure Bar Tests,

International Journal of Impact Engineering, Vol. 15, No. 6, 1994, pp. 723-733.

(6) Adharapurapu R.R., Jiang F., Bingert J.F., Vecchio K.S., Influence of Cold Work and

Texture on the High-Strain-Rate Response of Nitinol, Materials Science and Engineering,

Vol A257, 2010, pp. 5255-5267.

(7) Thamburaja P., Constituitive Equations for Martensitic Reorientation and Detwinning in

Shape-Memory Alloys, Journal of Mechanics and Physics of Solids, Vol. 53, 2005, pp.

825-856.

(8) Middleton L.A., Kennon N.F., Dunne D.P., Metallographic Method for Nitinol,

Metallography, Vol. 17, 1985, pp. 51-59.

(9) Eaton-Evans J., Dulieu J.M., Little E.G., Brown I.A., Observations During Mechanical

Testing of Nitinol, Mechanical Engineering Science, Vol. 222, 2007, pp 97-105.

(10) Pelton A.R., Russell S.M., DiCello J., The Physical Metallurgy of Nitinol for Medical

Applications, Journal of Materials, Vol. 55 No. 5, 2003, pp. 33-37.

(11) Nemat-Nassar S., Choi, J., Guo W., Issacs J. B., Very High Strain-Rate Response of a

NiTi Shape-Memory Alloy, Mechanics of Materials, Vol. 37, 2005, pp. 287-298.

(12) Wang F., Nitinol, A Memory Alloy in Action, Metallography, Vol. 19, 1986, pp. 257-259.

Page 63: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

49

(13) Bram M., Ahmad-Khanlou A., Heckmann A., Fuchs B., Buckremer H.P., Stover D.,

Powder Metallurgical Fabrication Processes for NiTi Shape Memory Alloy Parts,

Materials Science and Engineering, Vol. A337, 2002, pp. 254-263.

(14) Hartley R.S, Cloete T.J., Nurisk G.N., An Experimental Assesment of Friction Effects in

the Split Hopkinson Pressure Bar Using the Ring Compression Test, International Journal

of Impact Engineering, Vol 34, 2007, pp. 1705-1728.

(15) Dirk M., Gerard G., Bengt L., Evaluation of Stress-Strain Curve Estimates in Dynamic

Experiments, International Journal of Impact Engineering, Vol 37, 2010, pp. 161-169.

(16) Forrestal M.J., Wright T.W., Chen W., The Effect of Radial Inertia On Brittle Samples

During the Split Hopkinson Pressure Bar Test, International Journal of Impact

Engineering, Vol. 34, 2007, pp. 405-411.

(17) Zhao H., Gary G., Klepaczko J. R., On the Use of a Viscoelastic Split Hopkinson Pressure

Bar, International Journal of Impact Engineering, Vol. 19, No. 4, 1997, pp. 319-330.

(18) Huseyin S., Hamilton R., Canadinc D., Zhang X.Y., Gall K., Karaman I., Chumlyakov Y.,

and Maier H.J., Detwinning in NiTi Alloys, Metallurgical and Materials Transactions,

Vol. 34, 2003, pp. 5-13.

(19) Davies E.D.H., Hunter S.C., The Dynamic Compression Testing of Solids by the Method

of the Split Hopkinson Pressure Bar, Journal of the Mechanics and Physics of Solids,

Vol.11, 1963, 00.155-179.

Page 64: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

50

CHAPTER 4

PROCESS MECHANICS OF BALL BURNISHING OF SE508 NITI ALLOY

Abstract

Nitinol alloys have received considerable attentions in biomedical and aerospace

applications. Surface integrity of Nitinol (NiTi) devices by various fabrication processes is

crucial for their functionality and performance. In this study, surface integrity of SE508 NiTi

processed by low plastic burnishing (LPB) has been explored to tune the mechanical behavior

and microstructures. LPB is very promising to modify surface integrity due to its unique

capability to mechanically affect the material down to very deep subsurface on the order of a few

millimeters. The effects of LPB parameters, i.e. burnishing pressure, feed, speed, number of

path, and pattern on surface integrity characteristics such as roughness, microhardness, surface

topography, microstructure, and residual stresses are investigated. The burnished surfaces are

smoother than the as-machined ones. Strain-induced phase transformation from austenite to

martensite can be controlled by controlling the burnishing pressure. Significant strain hardening

occurs on the burnished surface. Highly compressive residual stresses on the surface and in the

subsurface are also measured, which is expected to significantly increase fatigue life of vascular

stents.

Page 65: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

51

4.1 Introduction

4.1.1 SE508 NiTi

Nitinol is a nickel-titanium alloy of near equiatomic composition with superelastic

mechanical properties as well as shape memory properties. Slight variations in the binary alloy

composition change the mechanical properties significantly with this particular material;

moreover, heat treatment history and finishing of the material play a vital role in the mechanical

properties as well. Typically, superelastic behavior occurs at elevated temperatures that approach

the melting point of a metal structure. SE508 NiTi is composed of nickel and titanium and the

accompanying characteristics of both metals distinguish overall properties of a superalloy yet

NiTi has superelastic features well below the melting point. As a result, these material properties

are advantageous to various biomedical and aerospace applications. NiTi was first discovered in

the early 1960’s and some of the first experimental work was conducted by the Naval Ordinance

Laboratory. Many of the early applications of NiTi focused on the shape memory effect where in

the recent years a lot of attention has been aimed toward the superelastic properties of NiTi with

particular emphasis on biomedical applications. The physiological conditions of the in vivo

environment within the human body are isothermal where the temperature of the body turns out

to be ideal for the superelastic properties of binary NiTi [1]. The non-linear effect of the

superelasticity of NiTi is based on a mechanical event where a diffusionless fully reversible

phase transformation evolves. The superelasticity effect of NiTi originates in an austenitic parent

phase where the continued application of stress results in a martensitic phase evolution and this

stress induced phase transition is commonly referred to as stress induced martensite (SIM). NiTi

is an ordered intermetallic that has an extremely narrow composition range below 630°C, which

Page 66: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

52

is observed in Fig 4.1 [2, 3]. Furthermore, the surface integrity of NiTi dictates important factors

regarding the resistance to corrosion and wear, which are primary failure mechanisms in NiTi

devices and components. The final surface condition of a NiTi structure has been shown to

correlate the biocompatibility of biomedical NiTi devices and components [4] where poor

surface finish of biomedical NiTi structures has been shown to produce poor resistance to

corrosion wear [5]. The contribution to high wear resistance of NiTi is due to several factors,

such as: pseudo-elasticity, strain hardening, as well as hardness [4, 6]. Hence, it would appear

that surface modification procedures have the capacity to enhance these features of a proposed

NiTi implantation device that would improve the ability for the device to mitigate corrosion and

wear.

Fig. 4.1 Phase diagram of a nickel-titanium binary alloy [3]

Page 67: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

53

4.1.2 How to improve fatigue life

Due to the elegant nature of (50.8at%Ni-49.2at%Ti) superelastic NiTi, a recent flurry of

attention has been focused on biomedical applications and for this reason it is critical that the

material has superior resistance to corrosion with excellent fatigue life while meeting and

exceeding FDA guidelines. According to the 2010 guideline established by the FDA, it is

recommended that vascular stents undergo bench top pulsatile fatigue testing replicating pressure

cycles at accelerated frequencies relative to human conditions. Hence, this particular guideline

indicates that a fatigue life requirement of 10 years equivalent to human in vivo physiological

conditions substantiates sufficient proof of safety for most patients [7]. Low plasticity burnishing

(LPB) is a novel technique in the field of engineered surfaces that can be tailored to suit the

desired application with improved surface integrity features. Hence, it is thereby postulated that

LPB is an ideal surface modification process with the capacity to improve features that initiate

failure mechanisms in superelastic NiTi biomedical devices and components. Low plasticity

burnishing is known for having deep surface layer compressive residual stresses of up to 1mm

that have been correlated to longer high cycle fatigue life. Similarly, LPB is a cold-working

process that enhances surface integrity features such as roughness, surface finish, and hardness

while providing corrosion resistance, wear resistance, and improved fatigue life [8, 10].

Conventional computerized numerically controlled (CNC) machine equipment can be used to

navigate the LPB tool with respect to the desired workspace. LPB provides a deep stable layer of

compressive residual stresses in nickel, titanium, steels, and aluminum alloys that can exceed

1mm in depth, which typically exceed the depth of typical corrosion pits [9, 11]. LPB is

Page 68: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

54

presumably an ideal surface modification process to enhance the overall surface integrity and

functionality of the material.

4.2 LPB method

4.2.1 Experimental setup

The process of low plasticity burnishing is a method of controlled burnishing with the use

of CNC programming logic. The process is implemented with the use of a high modulus freely

rotating spherical ball that is rolled over the surface of the desired workpiece under high pressure

[12]. The LPB method produces a deep layer of highly stable residual compressive stress with

minimal cold-work [13, 14]. A layout of the LPB tool functionality may be seen in Fig. 4.2.

Fig. 4.2 LPB tool diagram and details [8]

Page 69: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

55

A fixture was employed in the observations of spherical indentation on the workpiece. The

fixture design incorporated the use of a load cell such that load measurements could be made in

order to verify LPB input parameters. Fig. 4.3 illustrates the fixture incorporated throughout this

experimental investigation where a cavity on the top face of the fixture, along with a peripheral

fitting, was machined to securely hold the workpiece such that steady-state operating conditions

could be employed. The top plate of the fixture rests on 4 posts where a load cell securely rests

below capturing load while in operation. The Ecoroll LPB tool with a 12.7mm ball diameter was

manipulated by precision with the implementation of a Cincinnati Arrow 2 series CNC machine.

The LPB tool was held at a constant speed of 1000 mm/min in this experiment. It is

recommended to set the speed, pressure, and ball diameter to the highest values practical to

achieve such to increase the fatigue life [9]. The high pressures that are delivered by the LPB

tool are delivered by hydraulic fluid that tends to spill on the workpiece and surrounding areas.

The hydraulic fluid is machine friendly and acts as a coolant whereby the working fluid serves as

a mechanism of assistance rather than an inhibitor to the intended process.

Fig. 4.3 LPB test fixture for isolated experimental work

Page 70: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

56

4.2.3 Work material

The experimental work was carried out on (50.8at%Ni-49.2at%Ti) superelastic (SE508)

NiTi that was obtained by Nitinol Devices and Components (NDC), Fremont, California in thin

sheet form; this particular composition of NiTi is commonly referred to as SE508 NiTi by the

vendor. Similarly, this particular composition of binary nickel-titanium is commonly used in

biomedical applications since the mechanical properties are similar to biological tissue [15]. The

average grain size of the as-received austenitic parent phase NiTi sheet samples were on the

order of ~40µm. Cold-working is capable of transforming the parent austenite phase into a

martensite phase by localized stress distributions [9]. The as-received NiTi sheets are 1.5mm in

thickness and were cut to size by electro-discharge machining (EDM), and thereafter

mechanically polished to a mirror finish such to aid in the accuracy of surface profile

measurements [16]. Similarly, smoother surface to surface contact allows for better accuracy in

characterizing the experiemental results to Hertzian contact mechanics. Table 4.1 details the

composition of the work material supplied by NiTi Devices and Components (NDC).

SE508 NiTi chemical composition

Nickel (nominal): 55.8 wt.%

Titanium: Balance

Oxygen (max): 0.05 wt.%

Carbon (max): 0.02 wt.%

Table 4.1 Composition of SE508 NiTi

Page 71: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

57

4.3 LPB process analysis

4.3.1 Burnishing pressure/force

The idea is to induce small amounts of uniform plasticity where the tool is in contact with

the surface of the desired workpiece. The quasi-static mechanical properties of SE508 NiTi may

serve as a guideline to determine the critical region of desired plasticity. Similarly, Hertz theory

of elastic contact mechanics may be employed within the limits of small deformation [17, 18] to

characterize optimal LPB input parameters for SE508 NiTi. When considering the force input for

the LPB method, it is important to quantify several parameters such as the tool radius, the

effective curvature and stiffness of the tool with respect to the workpiece. These input variables

may be quantified by the following equations of Hertz elastic contact mechanics.

1

2

2

2

1

2

1 11*

EEE

(4.1)

21

11

RRR

(4.2)

2rPF

(4.3)

The material properties of the Ecoroll LPB tool and the workpiece may be found in Table

4.2. The effective modulus considers the tool and the workpiece; however, the workpiece has

two regions of elasticity where the austenitic and martensitic elastic regions were averaged as the

Page 72: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

58

overall modulus of elasticity for the workpiece. Since the workpiece is a thin plate of infinite

curvature, the value of R2 is null.

E*

[MPa]

E1

[MPa]

E2

[MPa]

v1

[-]

v2

[-]

R

[mm]

R1

[mm]

R2

[mm]

r

[mm]

37162

315000

37998

0.26

0.3

12.7

12.7

12.7

4.4 Hertz maximum contact pressure relation

The basis of the burnishing input pressures corresponds with Hertz theoretical maximum

contact pressure, p0, with respect to the acquired quasi-static mechanical properties of SE508

NiTi while in compression. The experimental plan of this investigation is based on Hertz contact

theory of elastic bodies for spherical contact on a flat surface and such corresponding values may

be observed in Table 4.3; the values in bold font correspond to inputs for this experimental work.

Hertzian peak pressure inputs were employed for samples 1-6 where samples 7-8 were inputs

based off of tool pressure. The theoretical Hertzian peak pressure values are plotted in

correspondence to the measured quasi-static stress-strain mechanical properties in Fig. 4.4. This

particular plot suggests that values of Hertz peak pressures correspond to true stress and strain

values and may serve as a valuable tool in determining optimal LPB input parameters. Based on

Hertzian elastic contact mechanics, the contact radius of the spherical indenter is a function of

the input load as well as the effective stiffness and curvatures of the two elastic materials in

contact. The maximum contact pressure derives from load input with respect to spherical load

Table 4.2 Input parameters for Hertzian contact theory

Page 73: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

59

case geometry. Furthermore, the approach of distant points, or depth, is a function of load input,

spherical load case geometry, and an overall effective stiffness and these values may be obtained

from the following equations.

3/1

*4

3

E

RPa

(3.4)

22

3

a

Ppo

(3.5)

3/1

2

2

*16

9

ER

P

(3.6)

Table 4.3 Spherical indentation and optimal LPB parameters experimental plan

Sample

[-]

Pressure

[MPa]

F

[N]

po

[MPa]

a

[mm]

z

[mm]

δ

[µm]

τmax

[MPa]

σ at r = a

[MPa]

1 0.15 19 500 0.13 0.06 3 155 67

2 0.61 77 800 0.21 0.10 7 248 107

3 1.19 151 1000 0.27 0.13 11 310 133

4 4.02 509 1500 0.40 0.19 26 465 200

5 9.53 1207 2000 0.54 0.26 45 620 267

6 13.57 1719 2250 0.60 0.29 57 698 300

7 15 1900 2327 0.62 0.30 61 721 310

8 20 2534 2561 0.69 0.33 74 794 341

Page 74: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

60

Fig 4.4 Quasi-static mechanical properties compared with Hertz peak pressure

4.5 Burnished depth/width

During spherical indentation on the surface of a flat contact area, the effect of sink-in and

pile-up occur where the load is applied. When the indented material is deformed elastically, the

effect of sinking-in occurs. However, when the indented material exceeds the yield stress, the

increase in plastic deformation of the indented material has a decrease in sinking-in and an

increase in pile-up. The presence of these particular characteristics causes inaccuracies in

determining the projected area of contact [19]. It is important to establish a high degree of

accuracy when evaluating the true contact area geometry yet the contact area from indentation

load-depth data is not necessarily a straightforward process since there is a dependence on the

amount of pile-up or sink-in of material around the edge of the indentation [18, 20]. Moreover,

the effect of pile-up is influenced by loading pressure and the strain hardening mechanical

properties of the material. A general trend can be noted whereas the increase of pressure has the

increase of dislocation density with the microstructure of the material and is the dominant factor

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14

σ

(G

Pa)

ε [mm/mm]

Quasi Static Peak Contact Pressure p0

Page 75: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

61

affecting fatigue life. However, there are a combined series of factors that influence the hardness

and surface roughness of the material and not a single stand alone factor [11]. In biomedical

applications, the effect of superelasticity is the attractive property of NiTi and it is vital to

preserve the superelastic features. The amount of cold work induced by low plasticity burnishing

is of low magnitude and yet the fatigue life can substantially be increased as well as corrosion

performance standards. The highest level of cold work induced in this particular investigation

was 0.2%. A Dektak II surface profilometer was used to measure the depth and width surface

profiles. A governing factor of the low plasticity burnishing process is the size of the tool tip and

the applied pressure whereby an acceptable feed may be established. Table 4.4 illustrates the

LPB pressure inputs with respect to contact width, depth, and contact radius. It was found that

the width of the indentation tracks changed very little with the increase in pressure although the

track width was substantially larger than the penetration depth, which was to be expected. The

contact radius pertains to the Hertzian contact model of an elastic solid. There was no sign of

indentation on the first of the three pressure inputs which indicates the indentation was purely

elastic up to a certain threshold.

Page 76: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

62

Table 4.4 LPB pressure input parameters

Pressure

[MPa]

Depth

[µm]

Width

[µm]

Contact Radius

[µm]

0.15 - - 134.2

0.61 - - 214.7

1.19 - - 268.4

4.02 0.17 1648.2 402.7

9.53 0.34 1814.8 536.8

13.57 1.33 1879.7 603.9

15 1.14 1666.7 624.5

20 4.18 2018.5 687.3

4.6 Maximum shear stress and location in the subsurface

When two elastic solid bodies come into contact, the onset of plasticity is dependent on

the hardness of the two bodies and loading conditions. For this particular contact problem, the

initiation of plastic yielding occurs beneath the surface while creating a stress field. The

subsurface shear stresses may be observed in equation 3.7, for = 0.3, [18]. A linear relationship

exists with the Hertzian theoretical values of shear stress and subsurface location. Moreover, a

general rule of thumb is that the locations of subsurface maximum shear stresses are about half

the distance of the contact radius. This particular characteristic is ideal for generating deep

subsurface compressive residual stresses by the use of low plasticity burnishing with a spherical

tool tip. The magnitude of the stress field increases as the indentation depth increases or

indentation force. Once the stress field reaches an equivalent point within the specimen, the

material will start to transform to martensite with an increasing hardness [17, 23]. According to

Page 77: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

63

Hertz theory of contact mechanics, we can observe in equation 3.7 that the maximum shear stress

is approximately 31% of the applied maximum contact pressure applied at the center of contact.

The contour plot in Fig. 4.5 [18] illustrates the variation of the stress field induced from spherical

indentation to an infinitely flat surface with respect to depth and width input parameters. The

Hertzian contact solutions hold true in a purely elastic state and a generalized Von Mises Stress

criterion is commonly used as a yielding envelope. Upon the average of the principal stresses

with the Von Mises criterion, we can assume that plastic flow occurs when the distortional strain

energy reaches a critical value and the result of the initiated yielding may be observed in

equation 3.8 [24]. A consideration of the Hertzian contact mechanics is the sensitivity of

Poisson’s ratio with respect to the contact angle. The load case of a spherical surface in contact

with an infinitely flat surface also bears the consideration of the contact angles and the effect of

the surface and subsurface stresses [25, 26, 27]. Similarly, the maximum tensile stress for this

load case may be ascertained by equation 3.9 where the maximum tensile stress resides at the

surface of the work material just outside the contact patch [28]. The radial stress is therefore

tensile outside the loaded area. It reaches a maximum value at the edge of the circle at r = a. This

is the maximum tensile stress occurring anywhere [18]. We can observe that the Poisson effect is

a parameter involved in the generated tensile stress field whereby a stress deviator has the

propensity to exist. It would also be desirable to the intended application for smooth surface to

surface contact where many studies indicate the difficulty in the assumptions of classical

Hertzian contact mechanics with relation to surface and subsurface stress fields. Kadiric et al

investigated tensile and shear stress on the surface and in the subsurface and found a linear trend

with the stress field and the surface peaks [29]. Hertz theory of contact mechanics between two

Page 78: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

64

elastic bodies imposes the assumption that the contact surfaces are topographically smooth

whereby perfect contact takes place. In reality all surfaces are rough to some extent where the

true contact takes place at the crest of the surface asperities [16]. Therefore, we can imply that

smoother surfaces allow a higher degree of accuracy in determining surface and subsurface stress

fields. This becomes an important factor in regard to subsurface residual stresses and the low

plasticity burnishing process.

azratp 48.0,031.0 01 (3.7)

22

13

2

32

2

21 2 Y (3.8)

0,213

102 zaratpr

(3.9)

Fig. 4.5 Contour plot illustrating the distribution of τmax at r = 0

Page 79: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

65

4.7 Experimental characterization of LPB tracks

On the premise that small deformations are imposed upon SE508 NiTi in this experiment,

we can use Hertz theory of contact for a basis model. There are challenges involved with

predicting an accurate baseline model when the elastic range of the material is far beyond

conventional. The aforementioned experimental plan constitutes the basis of the burnished input

pressures based of the Hertzian maximum contact pressure and experimentally determined

compressive quasi-static stress-strain values. The spring back due to superelasticity may be

observed in Fig. 4.6. Hence, it is necessary to experimentally determine process parameters for

low plasticity burnishing. It was determined that the first three applied loads were purely elastic

and the critical threshold to induce plastic deformation was established at approximately 4 MPa

with respect to a tool tip diameter of 12.7mm. The depth of penetration in Hertz theory of contact

mechanics resides in the elastic region and therefore does not indicate permanent indentation.

However, it is interesting to note the difference of the indentation depth induced by plasticity in

comparison with Hertz theory of elastic contact. While Hertz contact mechanics is not a gauge of

the plastic depth of penetration, we can ascertain that there is a large region of elastic springback

of this material. We can also use this methodology to predict elasto-plasticity and the evolution

of fully-plastic behavior upon the critical threshold of the burnishing pressure to induce

plasticity. Past studies indicate that relative high values of pressure and speed are dominating

factors where tool speed is a dominating factor in post-processing efficiency. The speed, or dwell

time, of the tool has an effect of the evolution of plasticity yet the tool speed was kept at a

relatively high value in comparison to literature in efforts for post-processing efficiency and

longer fatigue life [9]. An investigation by Seemikeri et al reflected that the dominating

Page 80: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

66

parameter was the applied pressure for increasing fatigue life whereby there was no single factor

that had an effect on surface roughness but a combination of parameters [9]. We can expect that

there will be greater hardness and pile-up when the spherical tool tip has greater contact area [17,

20, 30]. As one would expect, the track profiles vary in depth with respect to pressure inputs.

However, from Table 4.4 we can observe that there is very little variance in width of each of the

profile tracks. There was undetectable depth penetration with the first three pressure inputs

although the remaining pressure inputs reflected depth penetrations ranging from 0.2µm-4.0µm

with a percent cold work ranging from 0.01% - 0.2%, respectively. The cold work involved in

low plasticity burnishing is rather small and therefore the superelastic properties of SE508 NiTi

are not compromised.

Fig. 4.6 Hertz depth in comparison to experimental depth

0

5

10

15

20

25

0 10 20 30 40 50 60 70 80

Pre

ssure

(M

Pa)

Depth (µm)

Experimental Theoretical

Page 81: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

67

4.8 Conclusions

This investigation brings better understanding to process parameters to the low plasticity

burnishing process of SE508 NiTi. It was found that the quasi-static response of super elastic

NiTi correlates well with calculated Hertzian peak pressure contact of a sphere to flat surface

elastic body. Therefore, it is ideal to utilize quasi-static compressive stress-strain data to a

calculated peak pressure Hertzian model for ideal LPB loading parameters. Tool tip radius in

optimal LPB parameters plays a vital role in process efficiency where more or less surface area is

attained. However, this would imply that tool loading would increase where the tool would be

subject to accelerated tool wear. Similarly, larger diameter LPB tools would be more efficient in

regard to processing time.

Page 82: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

68

References

(1) Duerig T., Pelton A., Stockel D., An Overview of Nitinol Medical Applications, Materials

Science and Engineering, Vol. A273-275, 1999, pp. 149-160.

(2) Pelton A.R., Russell S.M., DiCello J., The Physical Metallurgy of Nitinol for Medical

Applications, Journal of Materials, Vol. 55 No. 5, 2003, pp. 33-37.

(3) Bram M., Ahmad-Khanlou A., Heckmann A., Fuchs B., Buckremer H.P., Stover D.,

Powder Metallurgical Fabrication Processes for NiTi Shape Memory Alloy Parts, Materials

Science and Engineering, Vol. A337, 2002, pp. 254-263.

(4) Imbeni V., Martini C., Prandstraller D., Poli G., Trepanier C., Duerig T.W., Preliminary

Study of Micro-Scale Wear Behavior of a NiTi Shape Memory Alloy, Wear, Vol. 254,

2003, pp. 1299-1306.

(5) Es-Souni M., Es-Souni M., Fischer-Brandies H., On the Properties of Two Binary NiTi

Shape Memory Alloys. Effect of Surface Finish on the Corrosion Behaviour and In Vitro

Biocompatibility, Biomaterials, Vol. 23, 2002, pp. 2887-2894.

(6) Liu R., Li D.Y., Modification of Archard’s Equation by Taking Account of

Elastic/Psuedoelastic Properties of Materials, Wear, Vol. 251, 2001, pp. 955-064.

(7) Pelton A.R., Schroeder V., Mitchell M.R., Gong Xian-Yan, Barney M., Robertson S.W.,

Fatigue and Durability of Nitinol Stents, Journal of the Mechanical Behavior of Biomedical

Materials, Vol. 1, 2008, pp. 153-164.

(8) Seemikeri C.Y., Brajmankar P.K., Mahagaonkar S.B., Investigations on Surface Integrity

of AISI 1045 Using LPB Tool, Tribology International, Vol. 41, 2008, pp. 724-734.

(9) Seemikeri C.Y., Brahmankar P.K., Mahagaonkar S.B., Low Plasticity Burnishing: An

Innovative Manufacturing Method for Biomedical Applications, Journal of Manufacturing

Science and Engineering, Vol. 130, 2008.

(10) El-Khabeery M.M., El-Axir M.H., Experimental Techniques for Studying the Effects of

Milling Roller-Burnishing Parameters on Surface Integrity, International Journal of

Machine Tools and Manufacture, Vol. 41, 2001, pp. 1705-1719.

Page 83: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

69

(11) Prevey P.S., Cammett J.T., The Influence of Surface Enhancement by Low Plasticity

Burnishing on the Corrosion Fatigue Performance of AA7075-T6, International Journal of

Fatigue, Vol. 26, 2004, pp. 975-982.

(12) Geetha M., Singh A.K., Asokamani R., Gogia A.K., Ti Based Biomaterials, the Ultimate

Choice for Orthopaedic Implants – A Review, Progress in Materials Science, Vol. 54,

2008, pp. 397-425.

(13) Prevey P.S., Ravindranath R.A., Shepard M., Gabb T., Case Studies of Fatigue Life

Improvement Using Low Plasticity Burnishing in Gas Turbine Engine Applications,

Journal of Engineering for Gas Turbines and Power, Vol. 128, 2006, pp. 865-872.

(14) Prevey P.S., Jayaraman N., Ravindranath R.A., Shepard M., Mitigation of Fretting Fatigue

Damage in Blade and Disk Pressure Faces with Low Plasticity Burnishing, Journal of

Engineering for Gas Turbines and Power, Vol. 132,No. 8, 2010.

(15) Morgan N.B., Medical Shape Memory Alloy Applications – The Market and its Products,

Materials Science and Engineering, Vol. 378, 2004, pp. 16-23.

(16) Greenwood J.A., Johnson K.L., Matsubara E., A Surface Roughness Parameter in Hertz

Contact, Journal of Wear, Vol. 100, 1984, pp. 47-57.

(17) Yan W., Sun Q., Feng X., Qian L., Analysis of Spherical Indentation of Superelastic Shape

Memory Alloys, International Journal of Solids and Structures, Vol. 44, 2007, pp. 1-17.

(18) Johnson K.L., Contact Mechanics, Cambridge University Press, London, 1985

(19) Bartier O., Hernot X., Mauvoisin G., Theoretical and Experimental Analysis of Contact

Radius for Spherical Indentation, Mechanics of Materials, Vol. 42, 2010, pp. 640-656.

(20) Taljat B., Pharr G.M., Development of Pile-up During Spherical Indentation of Elastic-

Plastic Solids, International Journal of Solids and Structures, Vol. 41, 2004, pp. 3891-3904.

(21) Wenyi Yan, Qingping Sun, Xi-Qiao Feng, Linmao Qian, Analysis of Spherical Indentation

of Superelastic Shape Memory Alloys, International Journal of Solids and Structures, Vol.

44, 2007, pp. 1-17

(22) Bei H., Lu Z.P., George E.P., Theoretical Strength and the Onset of Plasticity in Bulk

Metallic Glass Investigated by Nanoindentation with a Spherical Indenter, The American

Physical Society, Vol. 93, 2004, pp. 12504-1-4.

(23) Auricchio F., Taylor R. Shape-Memory Alloys: Modelling and Numerical Simulations of

the Finite-Strain Superelastic Behavior, Computer Methods in Applied Engineering, Vol,

143, 1997, pp. 175-194.

Page 84: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

70

(24) Adams G.G., Nosonovsky M., Contact Modeling – Forces, Tribology International, Vol.

33, 2000, pp. 431-442.

(25) Liu J., Wang X. Effects of Poisson’s Ratio on Scaling Law In Hertzian Fracture. Acta

Mechanica Solida Sincia, Vol. 22 No. 5, 2009, pp. 474-478.

(26) Knight M.G., De Lacerda L.A., Wrobel L.C., Henshall J.L., Parametric Study of the

Contact Stresses Around Spherical and Cylindrical Inclusions, Computational Materials

Science, Vol. 25, 2002, pp. 115-121.

(27) Brizmer V., Klingerman Y., Etison I., The Effect of Contact Conditions and Material

Properties on the Elasticity Terminus of a Spherical Contact, Vol. 43, 2006, pp. 5736-5749.

(28) Chen S.Y., Farris T.N., Chandrasekar S., Contact Mechanics of Hertzian Cone Cracking,

International Journal of Solids Structures, Vol. 32, 1995, pp. 329-340.

(29) Kadiric A., Sayles R.S., Bo Zhou X., Loannides E., A numerical Study of the Contact

Mechanics and Sub-Surface Stress Effects Experiences Over a Range of Machined Surface

Coatings in Rough Surface Contacts, Journal of Tribology, Vol. 125, 2003, pp. 720-730.

(30) Hernot X., Bartier O.,Bekouche R., El Abdi R., Mauvoisin G., Influence of Penetration

Depth and Mechanical Properties on Contact Radius Determination for Spherical

Indentation, International Journal of Solids and Structures, Vol. 43, 2006, pp. 4136-4153.

Page 85: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

71

CHAPTER 5

THE SURFACE INTEGRITY OF BALL BURNISHING OF SE508 NITI

Abstract

Superelastic Nitinol and other Nitinol alloys have been growing in numbers over the

recent years in the areas of aerospace and biomedical applications. Surface integrity of Nitinol

devices by various fabrication processes is advantageous for their functionality and performance.

In this study, surface integrity characteristics of Nitinol SE508 processed by low plastic

burnishing (LPB) have been explored to determine optimal loading and feed parameters. LPB is

a superior surface enhancement process to modify surface integrity due to its unique capability to

mechanically affect the material down to very deep subsurface on the order of a 500-1000μm.

The effects of LPB parameters, i.e. burnishing pressure, feed, speed, number of path, and pattern

on surface integrity characteristics such as roughness, microhardness, surface topography, and

microstructure are investigated. Strain rate characteristics are also of importance in this study on

the premise that quasi-static strain rate is highly similar to Hertzian peak pressure contact.

5.1 Introduction

For a number of years now, Nitinol has received a lot of focus from the biomedical

community as the superior biomaterial for medical implants and devices. Nitinol is a well sought

after material for medical devices since the material has excellent strain recovery abilities due to

its superelastic properties that are comparable to biological tissue [1]. Nitinol also has shape

Page 86: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

72

memory properties that weigh in more or less depending on the composition and treatment of the

material. Nitinol (NiTi) is an equiatomic alloy of nickel-titanium that undergoes a diffusionless

phase transformation from an austenitic phase to a martensitic phase with mechanical or thermal

loading. This particular phenomenon allows for large strain recovery that is rather elegant in

comparison to conventional metals. Shape memory applications of NiTi are employed when the

ability to utilize thermal loading may be controlled. Similarly, the physiological conditions of the

in vivo environment within the human body are isothermal where the temperature of the body

turns out to be ideal for the shape memory properties of binary NiTi [2]. Shape memory Nitinol

is often referred to as SM495, which would be equivalently 49.5 at% Ni. Similarly, superelastic

Nitinol is commonly referred to as SE508 with 50.8 at% Ni balanced with Ti along with trace

elements. The biocompatibility properties of Nitinol have received some concern to other

researchers due to high levels of nickel presence and the risk of cytocompatibility. Moreover,

there exists a consensus in the research community that the levels of nickel contained in NiTi

that are dissolved over time while in vivo are minimal and non evasive to the livelihood of the

patient. A more exaggerated application would be porous NiTi where more surface area is

exposed per a given volume. In such an application, the likelihood of nickel dissolving while in

vivo is expanded when porous NiTi medical devices are employed [3]. However, there are

certain advantages of porous NiTi implants that promote cellular growth in the downfall that

over the course of time nickel dissolution is of risk. This would imply that surface integrity and

functionality is an important factor with nickel-based biomedical implants. The benefits of

surface treated NiTi bring forth factors that are far more favorable for biomedical devices in a

physiological environment. In regard to surface enhancements of a NiTi, low plasticity

Page 87: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

73

burnishing (LPB) is a relatively novel surface enhancement, cold-working process, which has the

capacity to provide deep subsurface compressive residual stresses and improved overall surface

integrity and functionality characteristics. LPB is simply a surface treatment process where a

spherical burnishing ball is forced to float in a high-pressure fluid cap that is of noble hardness

and strength of the presumable body in contact. This hydraulically floated ball is pressed into the

surface of interest and rolled freely whereby local regions near the surface are deformed

plastically with minimal frictional loss. LPB is an ideal approach to improve surface integrity

being that the process induces minimal cold work and therefore not compromising the elastic

properties of SE508 NiTi. Similarly, LPB is known to improve surface finish while improving

low-cycle and high-cycle fatigue, surface hardness, corrosion resistance and wear resistance [4].

The compressive residual stresses produced from LPB are the driving mechanism that improves

the overall surface integrity as well as low-cycle and high-cycle fatigue life of the work material.

Moreover, the LPB process introduces less cold work at the surface and produces residual

compressive stresses more stable compared to other surface treatment methods [5]. In regard to

biocompatibility, surface enhanced NiTi has been observed to improve overall cytocompatibility

of NiTi [6]. When metal structures are work treated by cold working processes, fatigue life is

increased primarily due to the increase in dislocation densities within the lattice structure of the

material, which also generates compressive residual stresses within the surface and subsurface

layers of the working material. The series of plastic deformations that occur near the surface

layer of the material compress the polycrystalline solid and increase the bonding forces that

improve mechanical characteristics but vastly improve molecular stability of the lattice structure

of NiTi. Similarly, when cold work processes are employed to a given metal structure, there is

Page 88: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

74

generally an increase in strength and fatigue properties but losses in elastic behavior. The benefit

of LPB is that there is minimal cold work where elastic properties go nearly unscathed. Hence,

the superelastic properties of SE508 NiTi are of particular interest to the biomedical community

and are the focus of this study with emphasis on the optimal parameters of LPB. Moreover, the

purpose of this investigation is to determine optimal LPB parameters of SE508 NiTi in

correlation to desired indentation forces using the Hertzian contact theoretical model for a rigid

sphere in contact with an elastic half-space.

5.2 LPB method

5.2.1 Experimental setup

The process of LPB is a method of controlled burnishing with the use of CNC

programming logic. The process is implemented with the use of a high stiffness freely rotating

spherical ball that is rolled over the surface of the desired workpiece under controlled pressure

[7]. The LPB method produces a deep layer of highly stable residual compressive stress with

minimal cold-work of less than 3-5% [8, 9]. A fixture incorporated the use of a load cell such

that load measurements were made at a single load cycle per second in order to verify LPB input

parameters in steady-state loading conditions.

Page 89: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

75

Fig. 5.1 LPB EcoRoll tool on a load platform

Fig. 5.1 illustrates the fixture incorporated throughout this experimental investigation

where a cavity on the top face of the fixture was machined to securely hold the workpiece so that

steady-state operating conditions would be optimal. The top plate of the fixture rests on 4 posts

where a load cell securely rests below capturing load data while in operation. The Ecoroll LPB

tool with a 12.7mm ball diameter was logically controlled with a Cincinnati Arrow 2 series CNC

machine. The LPB tool was held at an arbitrary constant speed of 1000 mm/min during

experimental trials. The mechanics of the LPB tool allow for minimal friction since the spherical

indenter acts as a hydrostatic bearing. Moreover, the high pressures that are produced from the

LPB tool are delivered by hydraulic fluid that tends to spill on the workpiece and surrounding

areas. The hydraulic fluid is machine friendly and acts as a coolant whereby the working fluid

Page 90: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

76

serves as a mechanism of assistance rather than an inhibitor to the intended process. Similarly,

the working hydraulic fluid could be reclaimed in a manufacturing application to minimize cost

impact.

5.2.2 Work material

The experimental work in this study was carried out on SE508 NiTi, which was obtained

by Nitinol Devices and Components (NDC), in Fremont, California. The samples were 1.5 mm

in thickness and segmented to desired sections with the use of electro-discharged machining

(EDM). This particular composition of binary nickel-titanium is commonly used in biomedical

applications where the intent is to investigate the as-received state in comparison to varied LPB

parameters. It was observed that the average grain size of the as-received austenitic parent phase

Nitinol sheet samples were on the order of ~40µm. Moreover, it would be expected that grain

size would decrease in parallel to the loading path of the LPB tool. The forward stress

transformation from the parent austenite phase to a stress induced martensitic (SIM) phase is

achieved purely by mechanical loading in this study with thermal loading considered negligible.

In efforts to characterize with a level of precision, the as-received Nitinol sheets were

mechanically polished to a mirror finish (3µm) to aid in the accuracy of surface profile

measurements [10]. Similarly, smooth surface contact allows for better accuracy in

characterizing the experimental observations where equal distribution of loads may be

discernable.

Page 91: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

77

Table 5.1. SE508 NiTi composition by weight percentage

Ni Ti O C

55.8 wt% nominal Balance 0.05 wt% (max) 0.02 wt% (max)

5.3 LPB process analysis

5.3.1 LPB load cases

The parameters for applying the LPB method to a SE508 NiTi sheet sample were

investigated with various loads and feeds. The selected load cases were based on quasi-static

experimental compression testing and in correlation to Hertz theory of contact mechanics. It was

determined in preliminary investigations that the quasi-static load case in compression was

comparable to Hertzian peak pressure, p0, calculated by using Hertzian contact theory with a

sphere and a planar surface. The elastic modulus considered with the theoretical Hertzian contact

method, pertaining to NiTi, is modified as an overall elastic modulus with the austenitic and

martensitic phases of NiTi while in compression. In general, Hertzian contact mechanics are

based on conventional materials with a single elastic region although the median stiffness

concerning both austenitic and martensitic elastic regions are used as an effective elastic

modulus for the body in contact. A range of load cases was applied to capture the full spectrum

of the compressive stress-strain curve in forward stress transformations in a compressive stress

state. LPB pressure inputs will range from 1.2-15 MPa, which is the equivalent of 1.0-2.3 GPa

Hertzian peak pressure values. An overlap of constant tool feed was chosen as 40% coverage

based on the tool tip radius for lo ad dependent analysis. As observed in Table 5.2, the effect of

Page 92: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

78

LPB feed was varied with a constant Hertzian peak pressure of approximately 2.0 GPa. Loading

patterns were also investigated as observed in Fig. 5.2.

Table 5.2. Parameters investigated for optimal LPB of SE508 NiTi

Sample

[-]

Pressure

[MPa]

Feed

[mm]

No. of passes

[-]

% overlap

[-]

po

[MPa]

F

[N]

1 1.2 0.711 1 40 999.70 1501

2 4.0 0.711 1 40 1500.01 509

3 9.5 0.711 1 40 2000.09 1207

4 13.6 0.711 1 40 2250.16 1719

5 15.0 0.711 1 40 2326.57 1900

6 9.5 0.948 1 20 2000.09 1207

7 9.5 0.474 1 60 2000.09 1207

8 9.5 0.237 1 80 2000.09 1207

9 9.5 0.593 2 100 (Pattern A) 2000.09 1207

10 9.5 0.593 2 100 (Pattern B) 2000.09 1207

Fig. 5.2 LPB patterns of 100% coverage

Page 93: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

79

As observed in Fig. 5.3, the stress-strain relationship of SE508 NiTi in a quasi-static

compressive stress state correlates well with Hertzian theoretical peak contact pressure and

serves as a valuable tool in this study, see Fig. 5.3. The objective was to employ varied stress

states through the range of the stress-strain relationship in efforts to determine optimal LPB

characteristics. It was observed with the LPB process that stress-strain relations correlated well

with quasi-static strain-rate data in comparison to high strain-rate data from previous studies.

Fig. 5.3 Experimental stress-strain compared to Hertzian stress-strain

5.3.2 LPB contact mechanics

Due to the nature of the contact between the spherical tool face and the planar sample,

maximum tensile stresses are produced at the edge of the contact radii at the sample surface.

Shear stresses produced by the LPB tool are directly below the contact face of the spherical tool

and the mating surface. As a result of the contacting bodies with applied load, a characteristic

0.0

0.5

1.0

1.5

2.0

2.5

3.0

0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14

σ

(G

Pa)

ε [mm/mm]

Quasi Static Peak Contact Pressure p0

Page 94: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

80

stress field develops whereby shear and tensile stresses encompass the region of contact both

parallel and normal to loading. The tensile stressed regions are concentrated around the contact

area of the indenter whereby the contact radius is given by equation 5.5 as according to Hertz

contact mechanics. The Hertzian peak pressure is calculated by the relationship of an elastic

spherical body in contact with a planar elastic surface as observed in equation 5.7 in this

particular application. Similarly, maximum shear stresses are defined by equation 5.8 with two

elastic bodies being a sphere and a flat planar surface. Maximum shear stress occurs at the center

point of contact where peak shearing stress occurs at approximately 50% of the depth of the

contact radius. This particular characteristic allows for deep compressive residual stresses

beneath the contact surface of the LPB tool with respect to cold loading. Similarly, maximum

tensile stress values are expected to be much less due to the nature of the load case as observed

in equation 5.9. An effective modulus is evaluated with the LPB tool material properties and the

modified elastic moduli of the two-phase SE508 NiTi. The force generated from the LPB tool is

calculated by pure geometry as noted in equation 5.4. In regard to spherical contact with a planar

body, the contact radii is thereby infinite where only the tool tip radius is considered per equation

5.3. The mutual relative approach of distant points, indented depth, is characterized by equation

5.6 with respect to two elastic bodies in contact. For this particular study, adhesion is not

considered for the sake of brevity whereby the objective is to determine the adequate LPB

parameters to improve the surface integrity and functionality of SE508 NiTi.

Page 95: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

81

(5.1)

(5.2)

(5.3)

(5.4)

(5.5)

(5.6)

(5.7)

(5.8)

(5.9)

E* º1-n1

2

E 1

+1-n2

2

E 2

æ

èç

ö

ø÷

-1

E2 =Ea +Em

2

21

11

RRR

2rPF

3/1

*4

3

E

RPa

3/1

2

2

*16

9

ER

P

22

3

a

Ppo

azratp 48.0,031.0 01

0,213

102 zaratpr

Page 96: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

82

5.4 Experimental characterization of LPB tracks

5.4.1 Surface profiles at varied LPB load cases

Loading was monitored during LPB trials and measurements were evaluated through

each phase of loading. Surface profile measurements were taken in parallel and perpendicular to

each other on the loading surface. Of particular interests were the peaks and valleys of the

sample surface and the arithmetic average of surface roughness as noted in equation 5.10.

(5.10)

The relationship of surface roughness in comparison with to varied LPB pressure brings

forth some interest. It was observed that there was an increase in surface roughness with an

increase in LPB pressure and this is due to pileup from indentation force with the respective tool

radius. It was observed that surface roughness increased with the effect of loading pressure up to

a particular region, which suggests there are optimal loads for desired surface roughness, see Fig.

5.4.

Ra=1

Ly

x=0

x=L

ò dx

Page 97: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

83

Fig. 5.4 Surface roughness compared to LPB pressure

Similarly, each of the data points consists of three measurements for each point such that

a reasonable level of certainty could be justified. Moreover, the varied LPB loading pressure was

held at a constant 40% overlap coverage where the value of overlap coverage was calculated

from Hertzian contact area. It was observed that surface roughness decreased at a particular

threshold in the wake of plasticity. Similarly, the effect of feed was also investigated with a

constant Hertzian peak loading pressure of 2.0 GPa. It was observed that surface roughness was

relatively stable during the austenite-martensitic phase transformation. However, as overlap

increased, surface roughness also increased with the exception of a parallel and perpendicular

tool path of 100% coverage as noted in pattern A,B. Similarly, it was observed that a 3.5%

difference in the increase in LPB loading pressure had an 82% improvement in surface

roughness. With the understanding of LPB loading and surface roughness, there is an implied

load that is dependent of tool radii, which will achieve a desired surface roughness. In the event

that optimal LPB parameters are to be determined for a given application, there is reasonable

0

200

400

600

800

1000

Surf

ace

Ro

ugh

nes

s (A

ng)

Coverage (-)

Page 98: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

84

correlation that surface roughness alone would allow for a reasonable characterization for

optimal LPB parameters.

5.4.2 Microstructures on the top surface and in the subsurface

The grain structure of SE508 NiTi was evaluated in the as-received state along with the

samples with varied burnishing pressure. All evaluated samples were carefully polished down to

a mirror finish with a 3μm diamond Lecot spray. The regions of interest were evaluated in the

areas where LPB work was performed with the exception of the virgin sample. The samples were

prepared such that subsurfaces could be mounted for characterization and analysis. The etchant

that proved to be the most successful was a composition that was composed of the following

solution, HNO3+0.5HF+8.5H2O. It was observed that excessive craters would appear after

approximately 2 minutes although times under 1 minute were not enough to fully expose grains.

Once the grains were exposed, measurements of grain size were taken parallel to the loading path

where maximum compression occurs. It was found that with increasing LPB pressure, grain size

decreases in the loading path. Micrographs were dimensionally evaluated within the first 500μm

of subsurface depth where Maximum residual stress would be expected. Results determined that

SE508 NiTi in the as-received state had what appeared to be a symmetric grain structure of about

45μm in size. Observations of the decrease in grain size were found at the points where Hertz

peak pressure corresponded to plastic behavior in quasi-static experimental trials, see Fig. 5.5-6.

Page 99: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

85

Fig. 5.5 Comparison of grain size with LPB loading pressure

a) as received b) LPB tool pressure of 1.2 MPa

30

35

40

45

50

0 2 4 6 8 10 12 14 16

Gra

in S

ize (

µm

)

Burnishing Pressure (MPa)

Page 100: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

86

c) LPB tool pressure of 4.0 MPa d) LPB tool pressure of 9.5 MPa

e) LPB tool pressure of 13.6 MPa f) LPB tool pressure of 15.0 MPa

Fig 5.6 Grain characterization with varied LPB tool pressure

5.4.3 Surface/subsurface microhardness

The evaluation of surface and subsurface micro hardness was evaluated with the given

loads as observed in the test matrix. The nature of Hertzian spherical contact on a planar surface

Page 101: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

87

results in a stress field where maximum shear stress occurs below the contact surface. The

maximum shear stress occurs at approximately half of the contact radius below the contact

surface as stated in equation 5.8. Similarly, experimental results reflect a similar pattern to the

Hertzian model where peak hardness occurs. Microhardness was evaluated with a Vickers

indenter with a load of 100gf and a dwell time of 15s. The effect of loading was investigated

since loading is the critical parameter for optimal LPB parameters. As loading is a critical

parameter for optimal LPB applications, it would also suffice to say that surface roughness and

tool tip radius is of equal importance. The EcoRoll LPB tool that was used in this study has a tip

radius of 6.35mm. It was also of importance to have a smooth surface finish such that optimal

LPB parameters could be adequately investigated. Hardness results may be observed in Fig. 5.6

where surface and subsurface depths up to 500μm are evaluated. The hardness results indicate

that peak martensitic presence is below the surface. This is what would be expected from the

Hertzian model in correlation to SE508 NiTi.

Fig. 5.7 The comparison of microhardness and depth

200

220

240

260

280

300

320

340

360

380

0 50 100 150 200 250 300 350 400 450 500 550

Vic

kers

Hard

ness (

100

gf)

Depth (µm)

As-Received

1.2 MPa

4 MPa

9.5 MPa

13.6 MPa

15 MPa

Page 102: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

88

An important characteristic of Nitinol is the nonlinear relationship between

transformation strain and stress. The theoretical basis of the Clausius-Clapeyron model describes

the critical stress and temperature for stress induced martensite transformation and implies a

linear relationship between stress and phase transformation. However, this concept doesn’t hold

true for shape memory alloys [11]. By the stress-strain diffusionless phase transformation that

occurs with forward stress transformation, it may be observed with these results that martensitic

presence increases with loading. In general, hardness data from this study would indicate an

increase in martensitic presence up to approximately 0.5mm in the subsurface. It must be kept in

mind that the hardness to the forward transformation stress is not constant and may not serve as a

reasonable measure from material properties alone. This would indicate that an increase in

hardness results in an increase in the elastic modulus, which would impact the overall elasticity

of the material [12]. To what degree the elastic properties will be affected, is currently unknown

and further studies are required to determine such phenomena.

5.5 Conclusions

Hertz peak pressure may be used as a calculated method for optimal LPB parameters as it

closely relates to quasi-static stress-strain compressive behavior. In correlation to stress-strain

and subsurface hardness there is a distinction between the onset of experimentally observed

plastic behavior and peak pressure derived from the Hertzian model based on elastic properties.

It was observed that subsurface hardness increased as loading increased where the approach of

plastic behavior reveal a rapid increase in hardness. A rapid increase in martensite lathes would

properly characterize this phenomena and this occurs at the threshold of plastic behavior. The

Page 103: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

89

surface roughness of the samples increased with LPB pressure constrained to a constant feed up

to a particular region of plastic stress-strain behavior. A 3% difference in LPB pressure revealed

a 55% decrease in hardness. This would indicate there is a sensitive region where loading is

optimal. It was also observed that surface roughness increased with an increase in feed with the

exception of 100% overlap tool path. Perpendicular tool path proved to provide the best surface

roughness in comparison of feed patterns. Optimal burnishing parameters depend most on tool

tip radius, the initial surface roughness, and surface irregularities. Moreover, it would suffice to

say that increasing martensitic presence triggers plastic flow that can be directly correlated to

optimal LPB parameters for SE508 NiTi. This investigation serves as an academic contribution

to compressive stress-strain behavior in the event of rigid spherical indentation of a half-space

SE508 NiTi elastic solid body.

Page 104: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

90

References

(1) Morgan N.B., Medical Shape Memory Alloy Applications – The Market and its Products,

Materials Science and Engineering, Vol. 378, 2004, pp. 16-23.

(2) Duerig T., Pelton A., Stockel D., An Overview of Nitinol Medical Applications, Materials

Science and Engineering, Vol. A273-275, 1999, pp. 149-160.

(3) Ryhanen J., Shabalovskaya S., Yahia L.H., Bioperformance of Nitinol: In Vivo

Biocompatibility, Materials Science Forum, Vol 394-395, 2002, pp 139-144.

(4) Seemikeri C.Y., Brahmankar P.K., Mahagaonkar S.B., Low Plasticity Burnishing: An

Innovative Manufacturing Method for Biomedical Applications, Journal of Manufacturing

Science and Engineering, Vol. 130, 2008.

(5) Zhuang W., Wicks B., Numerical Analysis of Residual Stresses Induced by Low Plasticity

Burnishing, Key Engineering Materials, Vol. 233-236, 2003, pp. 809-814.

(6) Trepanier C., Leung T.K., Tabrizian M., Yahia L.H., Bienvenu J. G., Tanguay J. F., Piron

D.L., Bilodeau L., Preliminary Investigation on the Effects of Surface Treatments on the

response to Shape Memory NiTi Stents, Journal of Biomedical Materials, Vol 48, 1999, pp.

165-171.

(7) Geetha M., Singh A.K., Asokamani R., Gogia A.K., Ti Based Biomaterials, the Ultimate

Choice for Orthopaedic Implants – A Review, Progress in Materials Science, Vol. 54,

2009, pp. 397-425.

(8) Prevey P.S., Ravindranath R.A., Shepard M., Gabb T., Case Studies of Fatigue Life

Improvement Using Low Plasticity Burnishing in Gas Turbine Engine Applications,

Journal of Engineering for Gas Turbines and Power, Vol. 128, 2006, pp. 865-872.

(9) Prevey P.S., Jayaraman N., Ravindranath R.A., Shepard M., Mitigation of Fretting Fatigue

Damage in Blade and Disk Pressure Faces with Low Plasticity Burnishing, Journal of

Engineering for Gas Turbines and Power, Vol. 132,No. 8, 2010.

(10) Greenwood J.A., Johnson K.L., Matsubara E., A Surface Roughness Parameter in Hertz

Contact, Journal of Wear, Vol. 100, 1984, pp. 47-57.

Page 105: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

91

(11) Wu X.D., Sun G.J., Wu J.S., The Nonlinear Relationship between Transformation Strain

and Applied Stress for Nitinol, Journal of Material Letters, Vol 57, 2003, pp. 1334-1338.

(12) Yan W., Sun Q., Feng X., Qian L., Analysis of Spherical Indentation of Superelastic Shape

Memory Alloys, International Journal of Solids and Structures, Vol. 44, 2007, pp. 1-17.

Page 106: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

92

CHAPTER 6

SUMMARY

This thesis focuses on the compressive mechanical characteristics and behavior of

superelastic (SE508) Nitinol as it relates to low plasticity burnishing. Low plasticity burnishing

pertains to a manufacturing process that improves the overall surface integrity of a given material

by inducing compressive residual stresses. An initial study was done to have better

understanding of how SE508 responds to varied strain rates. At this time there is little research

available on compressive mechanical behavior of SE508 NiTi. A range of strain rates was

evaluated from 0.001s-1

to 6400s-1

. The high strain rate mechanical behavior of Nitinol was

evaluated with a Split Hopkinson Pressure Bar setup. A trend developed such that with

increasing strain rate there was increasing toughness of the test specimens. The diffusionless

phase transformation was less noticeable with increasing strain rate as well. The evaluation of

mechanical behavior provided a platform for further studies involving compressive mechanical

behavior of Nitinol.

In the efforts of improving the surface integrity of SE508 NiTi, it was exercised to

employ low plasticity burnishing, a modern manufacturing process. This particular loading

configuration was studied in great detail by Heinrich Hertz or otherwise known as Hertz theory

of contact mechanics. Hertz contact theory pertains to conventional metals with linearity in a

purely elastic state. An effective modulus was calculated from the nonlinear mechanical loading,

Page 107: PROCESS MECHANICS AND SURFACE INTEGRITY OF LOW …

93

while in an elastic state, to compare to the Hertz model. It was discovered that quasi-static stress-

strain behavior of SE508 NiTi correlates exceptionally well with Hertzian peak pressure output.

The prediction of mechanical behavior may be used for achieving optimal ball burnishing load

parameters. The process of low plasticity burnishing involves mild plastic flow in the event of a

compressive load whereby an elastic model is suitable for an application of this nature. During

the course of this work, there were efforts toward characterizing and better understanding

spherical indentation as well as LPB tool tracks. Due to the nature of superelastic spring-back

with SE508 NiTi, other parameters proved to be invalid and null for a superelastic material such

as Nitinol.

A further study was conducted to better learn optimal parameters for LPB with regard to

SE508 Nitinol. LPB pressure was compared to hardness with a number of samples to

substantiate that there is indeed an increase of depth hardness with the increase of LPB pressure

as one would expect. Moreover, the comparison of the Hertzian model to experimental surveys

confirmed that peak pressure was just below the surface as the Hertz model suggested. It was

also observed that surface roughness does not necessarily improve with 100% tool coverage over

the surface. It is also suggested that elastic properties are not compromised on the premise that

minimal cold work is done to the samples in this study. The trials of studies conducted in this

thesis contribute to a benchmark to impose optimal input parameters for low plasticity

burnishing and improving the performance of SE508 Nitinol.


Recommended