38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat Pumps is designed for quiet, reliable heating during the winter and cooling during the summer. With EER ratings up to 9.5, this heat pump system provides economy of operation through energy conservation when used with components designated by the manufacturer. The 38YCC recovers heat for indoor comfort from outdoor air during the heating season and, by automatically reversing the refrigerant system, removes indoor heat and excess humidity during the cooling season. All models are listed with UL (U.S. and Canada). FEATURES AND BENEFITS Electrical Range All units are offered in 208/230v single phase. Three--phase units are available from 036 through 060 sizes in 208/230v. Wide Range of Sizes All sizes of the 38YCC are offered in single phase 208--230v. The 38YCC 030 through 060 models are offered in 208/230v 3 phase. Unit Design All units are equipped with totally enclosed fan motors for greater reliability under adverse weather conditions. The large, wrap--around coil uses copper tube epoxy coated enhanced aluminum fin and is designed for optimum heat transfer and corrosion protection during heating and cooling. The vertical air discharge carries the sound and air up and away from adjacent patio areas and foliage. Coil can be cleaned with a common garden hose. WeatherArmort Cabinet A weather protective cabinet of pre--painted steel is protected underneath by a zinc galvanized coating for a finish that will last for many years. All screws on cabinet exterior are coated for a long--lasting, rust--resistant, quality appearance. Compressor Designed specifically for heat pump duty, with energy efficiency during heating and cooling operation. Each compressor is hermetically sealed against contamination to assure long life and dependable performance; compressors are also externally mounted on rubber isolators for quiet operation. For improved serviceability, all models are equipped with a compressor terminal plug. Continuous compressor operation is approved down to --30_F (--34.4_C) in the heating mode, and down to 55_F (12.8_C) in the cooling mode (unless equipped for low--ambient operation). Compressor Protection Each compressor is protected with internal temperature-- and current--sensitive overloads. Reliable standard components Includes a suction--tube accumulator that reduces the amount of liquid refrigerant that reaches the compressor; a lowpressure switch to stop the compressor if refrigerant charge is lost; a crankcase heater on all 3--phase units (except 030 size) to keep compressor oil warm and free of refrigerant for maximum lubricity; an internal compressor relief valve for high--pressure protection. 3--phase monitor board (scroll compressor models) Control board that monitors the electrical phase and prevents compressor operation if wired incorrectly.
Transcript
Page 1: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

38YCC (60 Hz)10 SEER Heat PumpExport ModelSizes 18 --- 60 (1---1/2 to 5 Nominal Tons)

Product Data

The 38YCC Outdoor Section of Split--System Heat Pumps isdesigned for quiet, reliable heating during the winter and coolingduring the summer. With EER ratings up to 9.5, this heat pumpsystem provides economy of operation through energyconservation when used with components designated by themanufacturer.The 38YCC recovers heat for indoor comfort from outdoor airduring the heating season and, by automatically reversing therefrigerant system, removes indoor heat and excess humidityduring the cooling season. All models are listed with UL (U.S. andCanada).

FEATURES AND BENEFITSElectrical RangeAll units are offered in 208/230v single phase. Three--phase unitsare available from 036 through 060 sizes in 208/230v.

Wide Range of SizesAll sizes of the 38YCC are offered in single phase 208--230v. The38YCC 030 through 060 models are offered in 208/230v 3 phase.

Unit DesignAll units are equipped with totally enclosed fan motors for greaterreliability under adverse weather conditions. The large,wrap--around coil uses copper tube epoxy coated enhancedaluminum fin and is designed for optimum heat transfer andcorrosion protection during heating and cooling. The vertical airdischarge carries the sound and air up and away from adjacentpatio areas and foliage. Coil can be cleaned with a common gardenhose.

WeatherArmort CabinetA weather protective cabinet of pre--painted steel is protectedunderneath by a zinc galvanized coating for a finish that will lastfor many years. All screws on cabinet exterior are coated for along--lasting, rust--resistant, quality appearance.

CompressorDesigned specifically for heat pump duty, with energy efficiencyduring heating and cooling operation. Each compressor ishermetically sealed against contamination to assure long life anddependable performance; compressors are also externally mountedon rubber isolators for quiet operation. For improved serviceability,all models are equipped with a compressor terminal plug.Continuous compressor operation is approved down to --30_F(--34.4_C) in the heating mode, and down to 55_F (12.8_C) in thecooling mode (unless equipped for low--ambient operation).

Compressor ProtectionEach compressor is protected with internal temperature-- andcurrent--sensitive overloads.

Reliable standard componentsIncludes a suction--tube accumulator that reduces the amount ofliquid refrigerant that reaches the compressor; a lowpressure switchto stop the compressor if refrigerant charge is lost; a crankcaseheater on all 3--phase units (except 030 size) to keep compressor oilwarm and free of refrigerant for maximum lubricity; an internalcompressor relief valve for high--pressure protection.

3--phase monitor board (scroll compressor models)

Control board that monitors the electrical phase and preventscompressor operation if wired incorrectly.

Page 2: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

2

FEATURES AND BENEFITS (CONT.)External Service ValvesService valves are brass, front seating type. The 38YCC has sweatfield connections. Valves are externally located so refrigerant tubeconnections can be made quickly and easily. Each valve has aservice port for ease of checking operating refrigerant pressures.

Easy ServiceabilityOne panel provides access to electrical controls. Removal of wiredome gives access to fan motor and removal of the top gives accessto the coil and compressor. All models are equipped with acompressor terminal plug.

Discharge MufflerMinimizes low frequency sound and pressure pulsation generatedby compressor discharge gas.

Defrost Control BoardIncorporates a defrost relay, defrost timer, and low--voltageterminations. The defrost control is a time and temperatureinitiation/termination control which includes 3 field--selectabletime periods of 30, 60, and 90 minutes.

PRODUCT NUMBER NOMENCLATURE38YCC 018 3

10 SEERElectric Heat Pump

Electrical Supply3=208/230---15=208/230---3

Nominal Capacity018 --- 1---1/2 Ton024 --- 2 Tons030 --- 2---1/2 Tons036 --- 3 Tons042 --- 3---1/2 Tons048 --- 4 Ton060 --- 5 Ton

X

X = Export— = Standard

A

Packaging

Series

A

REGISTERED

ISO 9001:2000

PHYSICAL DATAUNIT SIZE 018---3A 024---3A 030---3A, 5A 036---3A,5A 042---3B,5A 048---3B,5A 060---3A,5A

OPERATING WEIGHT (lb/kg) 127/57.6 143/64.9 157/71.2 176/79.8 195/88.5 219/99.3 237/107.5COMPRESSOR TYPE Recip Scroll Recip ScrollREFRIGERANT R---22Control PistonCharge (Lb/kg)@15 Ft./4.6m 4.25/1.9 4.63/2.1 5.19/2.4 6.38/2.9 7.88/3.6 9.38/4.3 10.5/4.8

COND FAN Propeller Type, Direct DriveAir Discharge VerticalAir Qty (CFM/L/S) 1700/802 2500/1180 3000/1415 3300/1557Motor HP 1/12 1/4Motor RPM 1100 1125 1100

COND COIL Copper Tube, Aluminum Plate FinFace Area sq ft / sq m 9.11/.85 12.42/1.15 14.8/1.37 18.5/1.72 22.40/2.08Fins per in./25.4 mm 20 25 20 25Rows 1Circuits 2 3 4 5

VALVE CONNECTION SweatVapor (in./mm)lD 5/8/15.88 3/4/19.05 7/8/22.23Liquid (in./mm)lD 3/8/9.53

REFRIG. TUBES*(in./mm) ODVapor (0---50 ft/0---15.24m Tube) 5/8/15.88 3/4/19.05 7/8/22.3Vapor (Max Diameter for LongLine Applications) 3/4/19.05 7/8/22.23 1---1/8/28.58

Liquid (0---50 ft./0---15.24 m/ TubeLength) 3/8/9.53

Liquid (For Long Line Applications) 3/8/9.53* For tubing sets between 50 and 175 ft (15.24 and 53.34 m) horizontal and/or 20 ft (6.1 m) vertical differential, consult Residential Split Systems Long---LineApplication Guideline.NOTE: See unit Installation Instructions for proper installation.

38YCC

Page 3: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

3

ELECTRICAL DATA

UNITSIZE V/PH

OPER VOLTS* COMPRESSOR FANFLA MCA

60°CMINWIRESIZE†

75°CMINWIRESIZE†

60°CMAXLENGTHft (m)‡

75°CMAXLENGTHft (m)‡

MAX FUSE**OR CKT BKRAMPSMax Min LRA RLA

018---3A

208---230/1 253 197

48.0 9.0 0.5 11.8 14 14 66 62 20024---3A 61.0 11.3 0.5 14.6 14 14 53 50 20030---3A 73.0 13.8 1.4 18.7 14 14 41 39 30036---3A 86.0 17.2 1.4 22.9 12 12 55 52 35042---3B 109.0 18.3 1.4 24.3 10 10 67 63 40048---3B 137.0 19.2 1.4 25.4 8 10 107 66 40060---3A 148.0 30.8 1.4 39.9 8 8 75 70 60030---5A

208/230/3 253 187

68.0 9.0 1.4 12.7 14 14 41 39 15036---5A 78.0 11.3 1.4 15.5 14 14 50 50 20042---5A 88.0 16.4 1.4 21.9 12 12 66 63 30048---5A 91.0 12.9 1.4 17.5 14 14 51 48 25060---5A 137.0 20.7 1.4 27.3 10 10 82 78 35* Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure.{ If wire is applied at ambient greater than 30˚C, consult Table 310---16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic---sheathed cable (NM), tradename ROMEX, shall be that of 60˚C conductors, per the NEC (ANSI/NFPA 70) Article 336---26. If other than uncoated (non---plated), 60 or 75˚C insulation, cop-per wire (solid wire for 10 AWG and smaller, stranded wire for larger than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).} Length shown is as measured 1 way along wire path between the unit and service panel for a voltage drop not to exceed 2%.** Time---delay fuse.FLA --- Full Load AmpsLRA --- Locked Rotor AmpsMCA --- Minimum Circuit AmpsRLA --- Rated Load AmpsNOTES:1. Control circuit is 24v on all units and requires external power source.2. Copper wire must be used from service disconnect to unit.3. All motors/compressors contain internal overload protection.

METERING DEVICEUNIT SIZE --- VOLTAGE, SERIES OUTDOOR PISTON INDOOR PISTON* REQUIRED SUB---COOLING _F (_C)

018---3A 42 55 12 (6.7)024---3A 49 63 12 (6.7)030---3A, 5A 55 70 12 (6.7)036---3A, 5A 57 70 14 (7.8)042---3B, 5A 63 78 16 (8.9)048---3B, 5A 70 86 15 (8.3)060---3A, 5A 76 96 10 (5.6)

* Piston listed is for any approved non---capillary tube coil combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil.

A--WEIGHTED SOUND POWER (dBA)

UNIT SIZESTANDARDRATING(dB)

TYPICAL OCTAVE BAND SPECTRUM (dB, without tone adjustment)

125 250 500 1000 2000 4000 800018---3A 78 49.5 58.0 66.5 69.5 67.0 66.5 59.524---3A 78 50.5 59.0 64.5 68.0 67.5 67.5 61.530---3A,5A 80 57.5 64.5 68.5 72.5 72.5 70.0 64.036---3A,5A 81 60.5 67.5 73.0 76.0 73.0 69.5 63.542---3B,5A 80 59.0 65.0 70.5 75.5 72.0 69.5 64.048---3B,5A 80 54.5 63.5 69.5 75.0 71.0 70.0 67.560---3A,5A 80 56.0 64.5 73.0 74.5 71.0 71.0 63.0

38YCC

Page 4: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

4

ACCESSORIESORDERING NUMBER DESCRIPTION

KAATD0101TDR Time--Delay Relay — All SizesKSALA0201R22 Low--Ambient Pressure Switch — All sizes

KSALA0401AAA*{ MotorMaster®— Low--Ambient Controller — Sizes 018–030; 036 (3A, 5A); 042 (3B, 5A); 048 (3B, 5A); 060 (3A, 5A)HC34GE232 (RCD) Ball Bearing Fan Motor — Sizes 018, 024HC40GE232 (RCD) Ball Bearing Fan Motor — Sizes 030 (3A, 5A); 036 (3A, 5A); 042 (3B, 5A); 048 (3B, 5A); 060 (3A, 5A)KAAFT0101AAA} Evaporator Freeze Thermostat — All SizesKHAIR0101AAA} Isolation Relay — All SizesKSACY0101AAA Cycle Protector — All SizesKSAHS0901AAA Start Assist — Capacitor and Relay—Size 030 (3A)KSAHS2101AAA Start Assist — Capacitor and Relay—Sizes 024 (3A); 036 (3A)KSAHS2001AAA Start Assist — Capacitor and Relay—Size 018 (3A)KSAHS1501AAA Start Assist — Capacitor and Relay — Sizes 042 (3B); 048 (3B)KSAHS1601AAA Start Assist — Capacitor and Relay — Size 060 (3A)KAACS0201PTC Start Assist — PTC — Sizes 018–030 (3A); 036 (3A); 042 (3B); 048 (3B); 060 (3A)

Standard Crankcase Heater — All Three PhaseKAACH1001AAA Crankcase Heater — 018–036 (3A)KAACH1201AAA Crankcase Heater — Sizes 042 (3B); 048 (3B); 060 (3A)KSASH0601COP Sound Hood — Size 042 (3B, 5A)KSASH2001BRL Sound Hood — Sizes 018–--030 (3A)KSASH2101COP Sound Hood — Sizes 048 (3B, 5A); 060 (3A, 5A)KHAOT0301FST Outdoor Thermostat — All SizesKHAOT0201SEC Secondary Outdoor Thermostat — All Sizes

KSATX0601HSO** TXV (Hard Shutoff) — Sizes 018–042KSATX0701HSO** TXV (Hard Shutoff) — Size 048KSATX1001HSO** TXV (Hard Shutoff) — Size 060KHATX0201RPB TXV (RPB) — Size 018KHATX0301RPB TXV (RPB) — Size 024KHATX0401RPB TXV (RPB) — Size 030KHATX0501RPB TXV (RPB) — Sizes 036, 042KHATX0601RPB TXV (RPB) — Sizes 048KHATX0701RPB TXV (RPB) — Sizes 060KHAHI0101HPS High--Pressure Switch — All Sizes

P504--8083S (RCD) Filter Drier — Bi--Flow — Sizes 018–036P504--8163S (RCD) Filter Drier — Bi--Flow — Sizes 042–060

KHALS0401LLS Liquid--Line Solenoid Valve (LSV) — All SizesKAACF1001MED Coastal Filter Kit — 018–030KAACF1101LRG Coastal Filter Kit — 036–060

* Isolation relay required.{ Fan motor with ball bearings required.} Use with low---ambient controller.** Addition of these accessories requires capacitor and relay compressor start assist on all single---phase reciprocating compressor applications.

ACCESSORY THERMOSTATSTHERMOSTAT / SUBBASE PKG. DESCRIPTION

TSTATCCPRH01---B* Thermidistatt Control — Non---Programmable/Programmable Thermostat with Humidity Control (For use in DualFuel, AC, HP, and 2S applications. Includes Outdoor Air Temperature Sensor.)

TSTATCCPHH01---B* HybridHeatt (Dual Fuel) Thermostat — Auto Changeover, 7---Day Programmable, °F/°C, Includes Outdoor Sensor(TSTATXXSEN01---B)

TSTATCCPHP01---B Thermostat — Auto Changeover, 7---Day Programmable, °F/°C, 2---Stage Heat, 1---Stage CoolTSTATCCNHP01---C Thermostat — Auto Changeover, Non---Programmable, °F/°C, 2---Stage Heat, 1---Stage Cool

TSTATCCSHP01 Standard Programmable Thermostat—Manual Changeover, 5---2 Day Programmable, °F/°C, 1---Stage Heat/ 1---StageCool

TSTATCCBHP01*---B Builder’s Thermostat — Heat Pump, Non---Programmable, °F/°C, 2---Stage Heat, 1---Stage Cool, Manual ChangeoverTSTATXXSEN01---B** Outdoor Air Temperature SensorTSTATXXNBP01 Backplate for Non---Programmable ThermostatTSTATXXPBP01 Backplate for Programmable Thermostat and Thermidistatt ControlTSTATXXSBP01 Backplate for Standard Programmable ThermostatTSTATXXBBP01 Backplate for Builder’s ThermostatTSTATXXCNV10{ Thermostat Conversion Kit (4 to 5 Wire) — 10 PackTB---PHP---01 Base Series Programmable HP Stat

TB---NHP---01 Base Series Non---programmable HP Stat* Do not use in zoning heat pump applications.** Outdoor temperature sensor is an accessory for all Carrier electronic thermostats, except the non---programmable air conditioner version and builder;sthermostats. It allows the temperature at a remote location (outdoors) to be displayed on the thermostat. The outdoor air temperature sensor must be usedwith the HybridHeatt (dual fuel) thermostat.

{ Thermostat conversion kit is a 24---vac accessory that can turn a 4---wire thermostat application into a 5---wire application. This kit can also be used to replace a broken thermostat wire, or add an extra wire when needed. The outdoor air temperature sensor is included with the Thermidistat Control andHybridHeatt (dual fuel) thermostat.

38YCC

Page 5: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

5

ACCESSORY USAGE GUIDELINE

ACCESSORYREQUIRED FOR

LOW---AMBIENT APPLICATIONS(Below 55° F / 12.78° C)

REQUIRED FOR LONG LINEAPPLICATIONS*

(Over 80 Ft. / 24.38 m)

REQUIRED FOR SEA COASTAPPLICATIONS

(Within 2 miles / 3.22 km)Accumulator No No No

Ball Bearing Fan Motor Yes{ No NoCompressor Start AssistCapacitor and Relay Yes{ Yes No

Crankcase Heater Yes{ Yes NoEvaporator Freeze Thermostat Yes{ No No

Isolation Relay Yes{ No No

Liquid Line Solenoid Valve No See Long Line ApplicationGuideline No

Motor Master® Controlor Low---ambient Pressure Switch Yes{ No No

Support Feet Recommended No Recommended* For tubing line sets between 80 and 200 ft. (24.38 and 60.96 m) and/or 20 ft. vertical (6.09 m) differential, refer to Residential Split System Long LineApplication Guideline.

{ Required for Low---Ambient Controller MotorMasterr Control only.

Accessory Description and Usage (Listed Alphabetically)1. Ball--Bearing Fan MotorA fan motor with ball bearings which permits speed reductionwhile maintaining bearing lubrication.

Usage Guideline:

Required on all units when MotorMasterr is used.

2. Compressor Start Assist -- Capacitor and RelayStart capacitor and relay gives a ”hard” boost to compressor motorat each start up.

Usage Guideline:

Required for reciprocating compressors in the followingapplications:

Long line

Low ambient cooling

Hard shut off expansion valve on indoor coil

Liquid line solenoid on indoor coil

Required for single--phase scroll compressors in thefollowing applications:

Long line

Low ambient cooling

Suggested for all compressors in areas with a history oflow voltage problems.

3. Compressor Start Assist — PTC TypeSolid state electrical device which gives a ”soft” boost to thecompressor at each start--up.

Usage Guideline:

Suggested in installations with marginal power supply.

4. Crankcase HeaterAn electric resistance heater which mounts to the base of thecompressor to keep the lubricant warm during off cycles. Improvescompressor lubrication on restart and minimizes the chance ofliquid slugging.

Usage Guideline:

Required in low ambient cooling applications.

Required in long line applications.

Suggested in all commercial applications.

5. Cycle ProtectorThe cycle protector is designed to prevent compressor shortcycling. This control provides an approximate 5--minute delay afterpower to the compressor has been interrupted for any reason,including power outage, protector control trip, thermostat jiggling,or normal cycling.

6. Evaporator Freeze ThermostatAn SPST temperature--actuated switch that stops unit operationwhen evaporator reaches freeze--up conditions.

Usage Guideline:

Required when low ambient kit has been added.

7. High Pressure SwitchA high pressure switch that protects unit against excessive pressure.

Usage Guideline:

Required in all heat pumps operated in dual fuelapplications.

8. Isolation RelayAn SPDT relay which switches the low--ambient controller out ofthe outdoor fan motor circuit when the heat pump switches toheating mode.

Usage Guideline:

Required in all heat pumps where low ambient kit hasbeen added.

9. Liquid--Line Solenoid Valve (LLS)An electrically operated shutoff valve which stops and startsrefrigerant liquid flow in response to compressor operation. It is tobe installed at the outdoor unit to control refrigerant off cyclemigration in the heating mode.

Usage Guideline:

An LLS is required in all long line heat pumpapplications to control refrigerant off cycle migration inthe heating mode. See Long Line Guideline.

10. Low--Ambient Pressure Switch KitA long life pressure switch which is mounted to outdoor unitservice valve. It is designed to cycle the outdoor fan motor in orderto maintain head pressure within normal operating limits(approximately 100 psig to 225 psig). The control will maintainworking head pressure at low--ambient temperatures down to 0_Fwhen properly installed.

Usage Guideline:

A Low--Ambient Pressure Switch or MotorMasterrLow--Ambient Controller must be used when coolingoperation is used at outdoor temperatures below 55_F(12.8_C).

38YCC

Page 6: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

6

Accessory Description and Usage (Listed Alphabetically) -- CONTINUED

11. MotorMasterr Low--Ambient ControllerA fan--speed control device activated by a temperature sensor,designed to control condenser fan motor speed in response to thesaturated, condensing temperature during operation in coolingmode only. For outdoor temperatures down to --20_F (--28.9_C), itmaintains condensing temperature at 100_F ±10_F (37.8_C ±5.5_C).

Usage Guideline:

A MotorMasterr Low Ambient Controller orLow--Ambient Pressure Switch must be used whencooling operation is used at outdoor temperaturesbelow 55_F (12.8_C).

Suggested for all commercial applications.

12. Outdoor Air Temperature SensorDesigned for use with Carrier Thermostats listed in thispublication. This device enables the thermostat to display theoutdoor temperature. This device also is required to enable specialthermostat features such as auxiliary heat lock out.

Usage Guideline:

Suggested for all Carrier thermostats listed in thispublication.

13. Outdoor ThermostatAn SPDT temperature--actuated switch which turns onsupplemental electric heaters when outdoor air temperature dropsbelow a user--selected set point.

Usage Guideline:

Electric supplemental heat applications in non--variablespeed indoor units when electric heat staging is desired.

Usage Guideline:

Some local codes may require limiting the heating headpressure in the vapor line in some applications.

14. Secondary Outdoor ThermostatAn SPDT temperature--actuated switch which turns on third--stageof supplemental electric heaters when outdoor air temperaturedrops below the second--stage set point.

Usage Guideline:

Outdoor thermostat applications where electric heater iscapable of 3--stage operation.

15. Snow StandCoated wire rack which supports unit 18 in. (457.2 mm) abovemounting pad to allow for drainage from unit base.

Usage Guideline:

Suggested in the following applications:

Heat pump installations in heavy snowfall areas.

Heat pump installations in snow drift locations.

Heat pump installations in areas of prolongedsubfreezing temperatures.

All commercial installations.

16. Sound HoodWraparound sound reducing cover for the compressor. Reduces thesound level up to 2 dBA.

Usage Guideline:

Suggested when unit is installed closer than 15 ft(4.57 m) to quiet areas, bedrooms, etc.

Suggested when unit is installed between two houses lessthan 10 ft (3.05 m) apart.

Usage Guideline:

Suggested in the following applications:

Heat pump installations in heavy snowfall areas.

Heat pump installations in snowdrift locations.

Heat pump installations in areas of prolongedsubfreezing temperatures.

All commercial installations.

17. Thermostatic Expansion Valve (TXV) Bi--FlowA modulating flow--control valve which meters refrigerant liquidflow rate into the evaporator in response to the superheat of therefrigerant gas leaving the evaporator.

Usage Guideline:

Required in all heat pump applications

18. Time--Delay RelayAn SPST delay relay which briefly continues operation of indoorblower motor to provide additional cooling after the compressorcycles off.

Note:Most indoor unit controls include this feature. For those thatdo not, use the guideline below.

Usage Guideline:

Accessory required to meet ARI rating, where indoornot equipped.

38YCC

Page 7: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

7

DIM

ENSIONS(ENGLISH)

38YCC

Page 8: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

8

DIM

ENSIONS(S.I.)

38YCC

Page 9: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

9

38YCCBALANCEPOINTWORKSH

EET(ENGLISH) OUTDOORTEMPERATURE,_F

38YCC048---3B,5A

38YCC042---3B,5A

38YCC

Page 10: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

10

38YCCBALANCEPOINTWORKSH

EET(S.I.)

BUILDINGHEATLOSS,KWUNITINTEGRAT�EDHEAT�INGCAPAC�ITY,KW

--20

--10

010

20

20 10

BASEDONI�NDOORENT.AI�RAT21ºC

ANDATR�ATEDCFM

38YCC060-3A,5A

FA4CNF(F,C)060

38YCC048-3B,5A

FA4CN(F,C)048

38YCC042-3B,5A

FA4CN(F,C)042

38YCC036-3A,5A

FA4CN(F,C)036

38YCC030-3A,5A

FA4CN(F,C)030

38YCC024-3A

FA4CN(F,C)024

38YCC018-3A

FA4CN(F,C)018

515

OUTDOORTEMPERATURE,_C

38YCC

Page 11: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

11

COMBINATION RATINGS*OUTDOORUNIT SIZE---SERIES

INDOOR UNIT

NOMINALAIR---FLOW

Cooling Capacity @ 95˚F (35˚C) Heating Capacity

RatedBTUH

CapacitykW

PowerkW

RatedEER

High---Temp @ 47˚F (8˚C) Low---Temp @ 17˚F (---8˚C)

CFM L/S RatedBTUH

CapacitykW

PowerkW

RatedBTUH

CapacitykW

PowerkW

018---3A

FB4BN(F,L)024 600 280 18000 5.27 1.89 9.50 18000 5.27 1.70 11400 3.34 1.52

FA4CN(F,C)018 600 280 18000 5.27 1.89 9.50 18000 5.27 1.70 11500 3.37 1.53

FA4CN(F,C)024 600 280 18200 5.33 1.92 9.50 18200 5.33 1.67 11700 3.43 1.56

024---3A

FB4BN(F,L)024 800 380 22600 6.62 2.51 9.00 22800 6.68 2.09 14000 4.10 1.78

FA4CN(F,C)024 800 380 23000 6.74 2.42 9.50 23000 6.74 2.11 14000 4.10 1.78

FA4CN(F,C)030 800 380 23400 6.86 2.46 9.50 23000 6.74 2.11 14000 4.10 1.78

030---3A,5A

FB4BN(F,L)036 1000 467 29200 8.56 3.17 9.20 29200 8.56 2.76 17500 5.13 2.33

FA4CN(F,C)030 1000 467 29600 8.67 3.12 9.50 29200 8.56 2.67 17500 5.13 2.33

FA4CN(F,C)036 1000 467 29600 8.67 3.18 9.30 29600 8.67 2.71 17800 5.22 2.37

036---3A,5A

FB4BN(F,L)036 1200 550 34200 10.02 3.80 9.00 36000 10.55 3.40 22000 6.45 2.93

FA4CN(F,C)036 1200 550 35000 10.25 3.68 9.50 35600 10.43 3.26 21800 6.39 2.78

FA4CN(F,C)042 1200 550 35700 10.46 3.76 9.50 36300 10.64 3.32 22300 6.53 2.84

042---3B,5A

FB4BN(F,L)048 1400 653 41000 12.01 4.56 9.00 42200 12.36 3.99 27000 7.91 3.44

FA4CN(F,C)042 1400 653 41000 12.01 4.56 9.00 42200 12.36 3.99 27000 7.91 3.44

FA4CN(F,C)048 1400 653 42000 12.31 4.67 9.00 42400 12.42 3.88 27000 7.91 3.44

048---3B,5A

FB4BN(F,L)048 1600 750 45500 13.33 5.06 9.00 47000 13.77 4.30 30200 8.85 4.02

FB4BN(F,L)060 1600 750 46500 13.62 5.17 9.00 47500 13.92 4.35 30400 8.91 4.05

FA4CN(F,C)048 1600 750 46500 13.62 4.89 9.50 47000 13.77 4.17 30200 8.85 3.85

FA4CN(F,C)060 1600 750 47500 13.92 5.00 9.50 47000 13.77 4.17 30200 8.85 3.85

060---3A,5AFB4BN(F,L)060 2000 919 56000 16.41 6.22 9.00 58000 16.99 5.31 38500 11.28 4.90

FA4CN(F,C)060 2000 919 56500 16.55 6.08 9.30 58000 16.99 5.15 38500 11.28 4.70* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:Cooling Standard: 80_F (27_C) db 67_F (19_C) wb indoor entering air temperature and 95_F (35_C) db air entering outdoor unit.High---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 47_F (8_C) db 43˚F (6_C) wb air entering outdoor unit.Low---Temp Heating Standard: 70_F (21_C) db indoor entering air temperature and 17_F (±9_C) db 15˚F (±10_C) wb air entering outdoor unit.

SEER — Seasonal Energy Efficiency RatioCOP— Coefficient of PerformanceTDR — Time---Delay RelayHSPF— Heating Seasonal Performance FactorEER — Energy Efficiency Ratio

38CKC

Page 12: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

12

DETAILEDCOOLINGCAPA

CITIES*

(ENGLISH)

COILAIR

CONDENSERENTERINGAIRTEMPERATURES

°F75

8595

105

115

125

CFM

EWB

Capacity

MBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

38YCC018--3AOutdoorSectionWithFA4CN(F,C)018IndoorSection

525

5716.99

16.99

1.63

16.19

16.19

1.70

15.34

15.34

1.78

14.48

14.48

1.86

13.57

13.57

1.95

12.60

12.60

2.03

62 6717.89

20.00

15.87

13.51

1.651.69

16.83

18.87

15.34

13.06

1.721.77

15.80

17.64

14.80

12.51

1.791.85

14.70

16.45

14.21

12.00

1.871.93

13.59

15.23

13.59

11.49

1.952.01

12.60

13.93

12.60

10.96

2.032.09

7221.82

10.94

1.72

20.96

10.63

1.81

19.87

10.21

1.90

18.57

9.69

1.99

17.21

9.17

2.08

15.85

8.67

2.17

600

5717.66

17.66

1.68

16.84

16.84

1.75

15.95

15.95

1.83

15.05

15.05

1.91

14.11

14.11

2.00

13.11

13.11

2.09

62 6718.34

20.40

16.88

14.21

1.691.73

17.22

19.29

16.31

13.81

1.761.81

16.17

18.00

15.71

13.25

1.841.89

15.07

16.73

15.07

12.73

1.911.97

14.10

15.47

14.10

12.21

2.002.05

13.11

14.15

13.11

11.66

2.092.13

7222.06

11.25

1.76

21.30

11.02

1.85

20.25

10.66

1.94

18.96

10.17

2.03

17.51

9.61

2.12

16.11

9.10

2.21

675

5718.30

18.30

1.72

17.38

17.38

1.80

16.49

16.49

1.88

15.52

15.52

1.96

14.55

14.55

2.05

13.52

13.52

2.14

62 6718.68

20.69

17.70

14.84

1.731.77

17.57

19.59

17.14

14.49

1.801.85

16.49

18.27

16.49

13.95

1.881.93

15.51

16.97

15.51

13.41

1.962.01

14.54

15.66

14.54

12.88

2.052.09

13.51

14.32

13.51

12.31

2.142.17

7222.18

11.50

1.79

21.51

11.36

1.89

20.49

11.02

1.98

19.24

10.58

2.07

17.77

10.03

2.16

16.31

9.50

2.25

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)024

1.01

1.01

FB4BN(F,L)024

1.00

1.00

COILAIR

CONDENSERENTERINGAIRTEMPERATURES

°F75

8595

105

115

125

CFM

EWB

Capacity

MBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

38YCC024--3AOutdoorSectionWithFA4CN(F,C)024IndoorSection

700

5722.31

22.31

2.03

21.31

21.31

2.16

20.25

20.25

2.28

19.23

19.23

2.41

18.20

18.20

2.55

17.10

17.10

2.69

62 6722.95

25.69

21.37

18.05

2.052.10

21.67

24.21

20.69

17.46

2.172.23

20.44

22.60

20.01

16.77

2.292.37

19.24

21.22

19.24

16.20

2.422.50

18.19

19.80

18.19

15.61

2.552.63

17.10

18.36

17.10

15.02

2.692.76

7227.97

14.36

2.15

26.89

13.98

2.29

25.50

13.47

2.44

23.81

12.84

2.59

22.22

12.25

2.73

20.71

11.70

2.88

800

5723.31

23.31

2.09

22.13

22.13

2.23

21.02

21.02

2.35

19.94

19.94

2.49

18.87

18.87

2.63

17.73

17.73

2.77

62 6723.65

26.14

22.86

19.08

2.102.15

22.21

24.68

22.00

18.54

2.232.28

21.02

23.00

21.02

17.87

2.352.42

19.94

21.52

19.94

17.27

2.492.55

18.87

20.08

18.87

16.67

2.632.68

17.72

18.62

17.72

16.07

2.772.82

7228.28

14.82

2.19

27.25

14.54

2.34

25.94

14.11

2.49

24.28

13.53

2.64

22.57

12.90

2.79

20.98

12.33

2.93

900

5724.14

24.14

2.15

22.87

22.87

2.29

21.68

21.68

2.42

20.54

20.54

2.56

19.42

19.42

2.70

18.23

18.23

2.84

62 6724.17

26.47

24.17

20.05

2.152.19

22.86

25.06

22.86

19.60

2.292.33

21.68

23.41

21.68

18.97

2.422.47

20.53

21.78

20.53

18.30

2.562.61

19.42

20.31

19.42

17.69

2.702.74

18.23

18.82

18.23

17.05

2.842.87

7228.48

15.27

2.24

27.50

15.05

2.39

26.26

14.73

2.54

24.62

14.17

2.69

22.86

13.54

2.84

21.17

12.95

2.99

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)030

1.02

1.02

FB4BN(F,L)024

0.98

1.04

Seenotesonpage13

38YCC

Page 13: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

13

DETAILEDCOOLINGCAPA

CITIES*

(ENGLISH)CONTINUED

COILAIR

CONDENSERENTERINGAIRTEMPERATURES˚F

7585

95105

115

125

CF

MEWB

CapacityMBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38YCC030--3AOutdoorSectionWithFA4CN(F,C)030IndoorSection

875

5728.61

28.61

2.62

27.37

27.37

2.79

26.09

26.09

2.95

24.78

24.78

3.12

23.41

23.41

3.30

21.98

21.98

3.47

62 6729.38

32.79

27.44

23.14

2.642.69

27.84

30.98

26.60

22.39

2.802.87

26.28

29.09

25.74

21.59

2.963.05

24.75

27.34

24.75

20.86

3.123.22

23.40

25.54

23.40

20.11

3.293.39

21.98

23.65

21.98

19.34

3.473.55

7235.73

18.36

2.74

34.43

17.93

2.94

32.69

17.30

3.13

30.57

16.49

3.33

28.61

15.77

3.51

26.70

15.07

3.69

1000

5729.83

29.83

2.70

28.43

28.43

2.87

27.10

27.10

3.04

25.73

25.73

3.22

24.30

24.30

3.39

22.79

22.79

3.57

62 6730.22

33.38

29.32

24.48

2.702.75

28.49

31.57

28.43

23.82

2.872.94

27.10

29.60

27.10

23.01

3.043.12

25.72

27.74

25.72

22.25

3.223.29

24.30

25.89

24.30

21.48

3.393.46

22.79

23.99

22.79

20.69

3.573.62

7236.10

18.99

2.80

34.90

18.67

3.00

33.25

18.14

3.20

31.16

17.39

3.39

29.08

16.62

3.58

27.05

15.89

3.76

1125

5730.89

30.89

2.76

29.37

29.37

2.95

27.95

27.95

3.12

26.52

26.52

3.30

25.04

25.04

3.48

23.47

23.47

3.66

62 6730.93

33.78

30.93

25.73

2.762.81

29.36

32.04

29.36

25.18

2.953.00

27.95

29.96

27.95

24.36

3.123.18

26.51

28.07

26.51

23.57

3.303.35

25.03

26.18

25.03

22.79

3.483.52

23.47

24.25

23.47

21.96

3.663.69

7236.34

19.56

2.86

35.20

19.34

3.06

33.64

18.90

3.26

31.59

18.22

3.46

29.35

17.41

3.65

27.29

16.68

3.83

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)036

1.00

1.02

FB4BN(F,L)036

0.99

1.02

COILAIR

CONDENSERENTERINGAIRTEMPERATURES

°F75

8595

105

115

125

CFM

EWB

Capacity

MBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

Total

Sens

]Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

38YCC036--3A,5AOutdoorSectionWithFA4CN(F,C)036IndoorSection

1050

5733.27

33.27

3.11

31.89

31.89

3.28

30.50

30.50

3.47

29.10

29.10

3.67

27.64

27.64

3.87

26.12

26.12

4.07

62 6734.36

38.15

31.64

26.68

3.133.18

32.69

36.49

30.67

25.88

3.303.39

30.96

34.44

29.75

25.02

3.483.60

29.27

32.49

28.79

24.20

3.673.79

27.62

30.55

27.62

23.39

3.863.99

26.11

28.51

26.11

22.55

4.074.19

7241.45

21.04

3.24

40.37

20.67

3.47

38.63

20.09

3.69

36.41

19.26

3.92

34.25

18.46

4.13

32.15

17.68

4.35

1200

5734.63

34.63

3.20

33.13

33.13

3.38

31.67

31.67

3.58

30.20

30.20

3.78

28.68

28.68

3.98

27.10

27.10

4.19

62 6735.30

38.94

33.75

28.06

3.203.26

33.48

37.23

32.67

27.49

3.403.47

31.71

35.00

31.71

26.62

3.583.68

30.19

33.00

30.19

25.78

3.783.87

28.67

31.00

28.67

24.95

3.984.08

27.09

28.94

27.09

24.10

4.194.28

7241.81

21.71

3.31

40.86

21.50

3.54

39.26

21.00

3.77

37.15

20.29

4.00

34.81

19.40

4.23

32.61

18.61

4.45

1350

5735.79

35.79

3.27

34.19

34.19

3.48

32.67

32.67

3.68

31.12

31.12

3.88

29.54

29.54

4.09

27.90

27.90

4.31

62 6736.07

39.37

35.48

29.38

3.283.33

34.24

37.76

34.24

28.97

3.493.55

32.66

35.52

32.66

28.16

3.683.76

31.12

33.40

31.12

27.27

3.883.96

29.54

31.34

29.54

26.41

4.094.16

27.90

29.25

27.90

25.53

4.314.37

7242.05

22.23

3.38

41.18

22.19

3.61

39.67

21.81

3.85

37.64

21.19

4.08

35.21

20.30

4.31

32.95

19.49

4.53

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)042

1.02

1.02

FB4BN(F,L)036

0.98

1.03

Seenotesonpage13

38YCC

Page 14: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

14

DETAILEDCOOLINGCAPA

CITIES*

(ENGLISH)CONTINUED

COILAIR

CONDENSERENTERINGAIRTEMPERATURES

°F75

8595

105

115

125

CFM

EWB

Capacity

MBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

38YCC042--3B,5AOutdoorSectionWithFA4CN(F,C)042IndoorSection

1225

5738.39

38.39

3.61

37.11

37.11

3.94

35.70

35.70

4.29

34.20

34.20

4.69

32.64

32.64

5.13

30.94

30.94

5.60

62 6739.87

43.68

36.08

30.15

3.643.73

38.27

42.15

35.24

29.55

3.984.08

36.56

40.30

34.36

28.79

4.334.46

34.71

38.29

33.38

27.94

4.714.86

32.84

36.10

32.32

27.03

5.145.27

30.95

33.87

30.95

26.10

5.605.74

7247.00

23.81

3.82

46.01

23.54

4.18

44.43

22.98

4.57

42.46

22.26

5.00

40.18

21.37

5.46

37.65

20.43

5.92

1400

5739.83

39.83

3.73

38.48

38.48

4.07

37.02

37.02

4.43

35.43

35.43

4.82

33.77

33.77

5.26

32.00

32.00

5.74

62 6740.68

44.35

38.39

31.77

3.743.83

39.08

42.87

37.52

31.28

4.094.18

37.35

41.00

36.54

30.60

4.454.56

35.47

38.88

35.47

29.71

4.824.97

33.76

36.62

33.76

28.77

5.265.38

31.99

34.31

31.99

27.82

5.745.85

7247.38

24.51

3.91

46.54

24.40

4.28

45.05

23.93

4.67

43.10

23.27

5.10

40.83

22.47

5.56

38.25

21.50

6.06

1575

5740.98

40.98

3.83

39.65

39.65

4.18

38.12

38.12

4.56

36.47

36.47

4.95

34.70

34.70

5.38

32.86

32.86

5.87

62 6741.36

44.78

40.39

33.23

3.843.92

39.74

43.37

39.74

32.89

4.184.27

38.12

41.49

38.12

32.26

4.564.65

36.46

39.31

36.46

31.38

4.955.07

34.69

37.01

34.69

30.42

5.385.49

32.85

34.64

32.85

29.43

5.865.95

7247.59

25.12

3.99

46.85

25.14

4.36

45.46

24.80

4.76

43.54

24.22

5.19

41.26

23.45

5.66

38.65

22.49

6.16

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)048

1.02

1.02

FB4BN(F,L)048

1.00

1.00

COILAIR

CONDENSERENTERINGAIRTEMPERATURES

°F75

8595

105

115

125

CFM

EWB

CapacityMBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

38YCC048--3B,5AOutdoorSectionWithFA4CN(F,C)048IndoorSection

1400

57 62 67 72

44.26

45.70

50.14

54.25

44.26

41.90

35.02

27.71

3.903.924.014.10

42.62

43.69

48.09

52.66

42.62

40.85

34.19

27.17

4.244.284.384.48

40.93

41.62

45.75

50.61

40.93

39.77

33.20

26.45

4.644.664.784.90

39.14

39.46

43.39

48.17

39.14

38.60

32.21

25.54

5.075.085.225.36

37.19

37.21

40.85

45.53

37.19

37.21

31.15

24.56

5.545.545.695.85

35.09

35.08

38.08

42.55

35.09

35.08

30.01

23.42

6.046.046.186.38

1600

5745.94

45.94

4.02

44.19

44.19

4.38

42.40

42.40

4.78

40.52

40.52

5.21

38.48

38.48

5.69

36.28

36.28

6.19

62 6746.64

50.89

44.64

36.97

4.034.11

44.60

48.90

43.48

36.23

4.394.49

42.46

46.50

42.38

35.30

4.784.89

40.52

43.99

40.52

34.25

5.215.34

38.47

41.41

38.47

33.18

5.695.80

36.27

38.57

36.27

32.01

6.196.29

7254.74

28.60

4.20

53.26

28.20

4.59

51.30

27.59

5.01

48.84

26.73

5.46

46.16

25.76

5.96

43.16

24.65

6.49

1800

5747.27

47.27

4.13

45.49

45.49

4.50

43.60

43.60

4.90

41.66

41.66

5.35

39.55

39.55

5.82

37.25

37.25

6.33

62 6747.55

51.43

46.77

38.82

4.154.21

45.52

49.46

45.52

38.18

4.504.59

43.59

47.06

43.59

37.30

4.904.99

41.65

44.49

41.65

36.24

5.355.44

39.54

41.83

39.54

35.13

5.825.92

37.25

38.96

37.25

33.93

6.336.41

7255.05

29.42

4.30

53.64

29.14

4.69

51.76

28.67

5.11

49.33

27.87

5.56

46.62

26.93

6.06

43.65

25.89

6.59

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)060

1.02

1.02

FB4BN(F,L)048

0.98

1.03

FB4BN(F,L)060

1.00

1.06

Seenotesonpage13

38YCC

Page 15: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

15

DETAILEDCOOLINGCAPA

CITIES*

(ENGLISH)CONTINUED

COILAIR

CONDENSERENTERINGAIRTEMPERATURES

°F75

8595

105

115

125

CFM

EWB

CapacityMBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

Capacity

MBtuh[

Sys.

Power

kW**

CapacityMBtuh[

Sys.

Power

kW**

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

Total

Sens]

38YCC060--3A,5AOutdoorSectionWithFA4CN(F,C)060IndoorSection

1750

5753.43

53.43

4.83

51.50

51.50

5.28

49.51

49.51

5.79

47.46

47.46

6.34

45.26

45.26

6.94

42.87

42.87

7.56

62 6755.19

60.85

50.87

42.55

4.864.92

52.68

58.39

49.56

41.55

5.315.41

50.23

55.36

48.28

40.25

5.815.95

47.79

52.52

46.93

39.06

6.356.49

45.28

49.64

45.28

37.87

6.947.09

42.87

46.55

42.87

36.59

7.567.71

7266.10

33.65

5.01

64.18

33.00

5.50

61.70

32.11

6.04

58.70

31.00

6.63

55.30

29.68

7.27

51.95

28.44

7.92

2000

5755.61

55.61

4.97

53.45

53.45

5.46

51.28

51.28

5.96

49.10

49.10

6.52

46.79

46.79

7.12

44.31

44.31

7.75

62 6756.36

61.74

54.29

44.93

4.985.05

53.85

59.31

52.79

44.05

5.475.54

51.30

56.50

51.30

42.94

5.966.08

49.10

53.21

49.10

41.54

6.526.64

46.79

50.25

46.79

40.33

7.127.23

44.30

47.11

44.30

39.02

7.757.86

7266.76

34.79

5.14

64.94

34.28

5.64

62.52

33.49

6.18

59.64

32.49

6.76

56.24

31.25

7.40

52.53

29.87

8.07

2250

5757.26

57.26

5.11

55.18

55.18

5.61

52.72

52.72

6.12

50.43

50.43

6.68

48.03

48.03

7.29

45.46

45.46

7.93

62 6757.32

62.35

57.32

47.15

5.115.18

55.17

59.97

55.17

46.41

5.605.67

52.72

57.16

52.72

45.38

6.126.21

50.42

53.72

50.42

43.91

6.686.78

48.02

50.69

48.02

42.67

7.297.38

45.45

47.50

45.45

41.32

7.938.01

7267.18

35.82

5.27

65.44

35.45

5.77

63.07

34.77

6.31

60.23

33.84

6.90

56.79

32.67

7.53

53.13

31.32

8.21

CoolingIndoorModel

Capacity

Power

*FB4BN(F,L)060

0.99

1.02

NOTE:Whentherequireddatafallbetweenthepublisheddata,interpolationmaybeperformed.Extrapolationisnotanacceptablepractice.

*DetailedcoolingcapacitiesarebasedonindoorandoutdoorunitatthesameelevationperARIstandard210/240---94.Ifadditionaltubinglengthand/orindoorunitislocatedaboveoutdoorunit,aslightvariationincapacitymay

occur.

{Totalandsensiblecapacitiesarenetcapacities.Blowermotorheathasbeensubtracted.

}Sensiblecapacitiesshownarebasedon80˚F(27˚C)enteringairattheindoorcoil.Forsensiblecapacitiesatotherthan80˚F(27˚C),deduct835Btuh(245kW)per1000CFM(480L/S)ofindoorcoilairforeachdegreebelow

80˚F(27˚C),oradd835Btuh(245kW)per1000CFM(480L/S)ofindoorcoilairperdegreeabove80˚F(27˚C).

**UnitkWistotalofindoorandoutdoorunitkilowatts.

EWB---EnteringWetBulb

38YCC

Page 16: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

16

DETAILEDCOOLINGCAPA

CITIES*

(S.I.)

COILAIR

CONDENSERENTERINGAIRTEMPERATURES˚C

23.89

29.44

3540.56

46.11

51.67

CFM

EWB

CapacityMBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38YCC018--3AOutdoorSectionWithFA4CN(F,C)018IndoorSectione

250

144.98

4.98

1.63

4.74

4.74

1.70

4.49

4.49

1.78

4.24

4.24

1.86

3.98

3.98

1.95

3.69

3.69

2.03

17 195.245.86

4.653.96

1.651.69

4.935.53

4.503.83

1.721.77

4.635.17

4.333.66

1.791.85

4.314.82

4.163.52

1.871.93

3.984.46

3.983.37

1.952.01

3.694.08

3.693.21

2.032.09

226.39

3.21

1.72

6.14

3.12

1.81

5.82

2.99

1.90

5.44

2.84

1.99

5.04

2.69

2.08

4.64

2.54

2.17

285

145.18

5.18

1.68

4.93

4.93

1.75

4.67

4.67

1.83

4.41

4.41

1.91

4.13

4.13

2.00

3.84

3.84

2.09

17 195.375.98

4.954.16

1.691.73

5.055.65

4.784.04

1.761.81

4.745.27

4.603.88

1.841.89

4.424.90

4.423.73

1.911.97

4.134.53

4.133.58

2.002.05

3.844.15

3.843.42

2.092.13

226.46

3.30

1.76

6.24

3.23

1.85

5.93

3.12

1.94

5.56

2.98

2.03

5.13

2.82

2.12

4.72

2.67

2.21

320

145.36

5.36

1.72

5.09

5.09

1.80

4.83

4.83

1.88

4.55

4.55

1.96

4.26

4.26

2.05

3.96

3.96

2.14

17 195.476.06

5.194.35

1.731.77

5.155.74

5.024.24

1.801.85

4.835.35

4.834.09

1.881.93

4.554.97

4.553.93

1.962.01

4.264.59

4.263.77

2.052.09

3.964.20

3.963.61

2.142.17

226.50

3.37

1.79

6.30

3.33

1.89

6.00

3.23

1.98

5.64

3.10

2.07

5.21

2.94

2.16

4.78

2.78

2.25

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)024

1..01

1.01

FB4BN(F,L)024

1.00

1.00

COILAIR

CONDENSERENTERINGAIRTEMPERATURES˚C

23.89

29.44

3540.56

46.11

51.67

CFM

EWB

CapacityMBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38YCC024--3AOutdoorSectionWithFA4CN(F,C)024IndoorSection

330

146.54

6.54

2.03

6.24

6.24

2.16

5.93

5.93

2.28

5.63

5.63

2.41

5.33

5.33

2.55

5.01

5.01

2.69

17 196.727.53

6.265.29

2.052.10

6.357.09

6.065.12

2.172.23

5.996.62

5.864.91

2.292.37

5.646.22

5.644.75

2.422.50

5.335.80

5.334.57

2.552.63

5.015.38

5.014.40

2.692.76

228.20

4.21

2.15

7.88

4.10

2.29

7.47

3.95

2.44

6.98

3.76

2.59

6.51

3.59

2.73

6.07

3.43

2.88

380

146.83

6.83

2.09

6.49

6.49

2.23

6.16

6.16

2.35

5.84

5.84

2.49

5.53

5.53

2.63

5.19

5.19

2.77

17 196.937.66

6.705.59

2.102.15

6.517.23

6.445.43

2.232.28

6.166.74

6.165.24

2.352.42

5.846.31

5.845.06

2.492.55

5.535.88

5.534.89

2.632.68

5.195.46

5.194.71

2.772.82

228.28

4.34

2.19

7.98

4.26

2.34

7.60

4.14

2.49

7.11

3.96

2.64

6.61

3.78

2.79

6.15

3.61

2.93

425

147.07

7.07

2.15

6.70

6.70

2.29

6.35

6.35

2.42

6.02

6.02

2.56

5.69

5.69

2.70

5.34

5.34

2.84

17 197.087.75

7.085.87

2.152.19

6.707.34

6.705.74

2.292.33

6.356.86

6.355.56

2.422.47

6.026.38

6.025.36

2.562.61

5.695.95

5.695.18

2.702.74

5.345.52

5.345.00

2.842.87

228.34

4.47

2.24

8.06

4.41

2.39

7.69

4.32

2.54

7.21

4.15

2.69

6.70

3.97

2.84

6.20

3.79

2.99

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)030

1..02

1.02

FB4BN(F,L)024

0.98

1.04

Seenotesonpage17

38YCC

Page 17: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

17

DETAILEDCOOLINGCAPA

CITIES*

(S.I.)CONTINUED

COILAIR

CONDENSERENTERINGAIRTEMPERATURES˚C

23.89

29.44

3540.56

46.11

51.67

CFM

EWB

CapacityMBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38YCC030--3AOutdoorSectionWithFA4CN(F,C)030IndoorSection

415

148.38

8.38

2.62

8.02

8.02

2.79

7.64

7.64

2.95

7.26

7.26

3.12

6.86

6.86

3.30

6.44

6.44

3.47

17 198.619.61

8.046.78

2.642.69

8.169.08

7.806.56

2.802.87

7.708.52

7.546.33

2.963.05

7.258.01

7.256.11

3.123.22

6.867.48

6.865.89

3.293.39

6.446.93

6.445.67

3.473.55

2210.47

5.38

2.74

10.09

5.25

2.94

9.58

5.07

3.13

8.96

4.83

3.33

8.38

4.62

3.51

7.82

4.41

3.69

470

148.74

8.74

2.70

8.33

8.33

2.87

7.94

7.94

3.04

7.54

7.54

3.22

7.12

7.12

3.39

6.68

6.68

3.57

17 198.869.78

8.597.17

2.702.75

8.359.25

8.336.98

2.872.94

7.948.67

7.946.74

3.043.12

7.548.13

7.546.52

3.223.29

7.127.59

7.126.29

3.393.46

6.687.03

6.686.06

3.573.62

2210.58

5.56

2.80

10.22

5.47

3.00

9.74

5.32

3.20

9.13

5.10

3.39

8.52

4.87

3.58

7.93

4.66

3.76

530

149.05

9.05

2.76

8.60

8.60

2.95

8.19

8.19

3.12

7.77

7.77

3.30

7.34

7.34

3.48

6.88

6.88

3.66

17 199.069.90

9.067.54

2.762.81

8.609.39

8.607.38

2.953.00

8.198.78

8.197.14

3.123.18

7.778.22

7.776.91

3.303.35

7.337.67

7.336.68

3.483.52

6.887.10

6.886.44

3.663.69

2210.65

5.73

2.86

10.31

5.67

3.06

9.86

5.54

3.26

9.26

5.34

3.46

8.60

5.10

3.65

8.00

4.89

3.83

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)036

1.00

1.02

FB4BN(F,L)036

0.99

1.02

COILAIR

CONDENSERENTERINGAIRTEMPERATURES˚C

23.89

29.44

3540.56

46.11

51.67

CFM

EWB

CapacityMBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38YCC036--3A,5AOutdoorSectionWithFA4CN(F,C)036IndoorSection

495

149.75

9.75

3.11

9.34

9.34

3.28

8.94

8.94

3.47

8.53

8.53

3.67

8.10

8.10

3.87

7.65

7.65

4.07

17 1910.07

11.18

9.277.82

3.133.18

9.58

10.69

8.997.58

3.303.39

9.07

10.09

8.727.33

3.483.60

8.589.52

8.437.09

3.673.79

8.098.95

8.096.85

3.863.99

7.658.35

7.656.61

4.074.19

2212.14

6.16

3.24

11.83

6.05

3.47

11.32

5.89

3.69

10.67

5.64

3.92

10.04

5.41

4.13

9.42

5.18

4.35

565

1410.15

10.15

3.20

9.71

9.71

3.38

9.28

9.28

3.58

8.85

8.85

3.78

8.40

8.40

3.98

7.94

7.94

4.19

17 1910.34

11.41

9.898.22

3.203.26

9.81

10.91

9.578.06

3.403.47

9.29

10.25

9.297.80

3.583.68

8.859.67

8.857.55

3.783.87

8.409.08

8.407.31

3.984.08

7.948.48

7.947.06

4.194.28

2212.25

6.36

3.31

11.97

6.30

3.54

11.50

6.15

3.77

10.89

5.94

4.00

10.20

5.68

4.23

9.56

5.45

4.45

635

1410.49

10.49

3.27

10.02

10.02

3.48

9.57

9.57

3.68

9.12

9.12

3.88

8.66

8.66

4.09

8.18

8.18

4.31

17 1910.57

11.53

10.39

8.61

3.283.33

10.03

11.06

10.03

8.49

3.493.55

9.57

10.41

9.578.25

3.683.76

9.129.79

9.127.99

3.883.96

8.659.18

8.657.74

4.094.16

8.178.57

8.177.48

4.314.37

2212.32

6.51

3.38

12.07

6.50

3.61

11.62

6.39

3.85

11.03

6.21

4.08

10.32

5.95

4.31

9.65

5.71

4.53

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)042

1.02

1.02

FB4BN(F,L)036

0.98

1.03

Seenotesonpage17

38YCC

Page 18: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

18

DETAILEDCOOLINGCAPA

CITIES*

(S.I.)CONTINUED

COILAIR

CONDENSERENTERINGAIRTEMPERATURES˚C

23.89

29.44

3540.56

46.11

51.67

CFM

EWB

Capacity

MBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38YCC042--3B,5AOutdoorSectionWithFA4CN(F,C)042IndoorSection

580

1411.25

11.25

3.61

10.87

10.87

3.94

10.46

10.46

4.29

10.02

10.02

4.69

9.56

9.56

5.13

9.07

9.07

5.60

17 1911.68

12.80

10.57

8.83

3.643.73

11.21

12.35

10.33

8.66

3.984.08

10.71

11.81

10.07

8.44

4.334.46

10.17

11.22

9.788.19

4.714.86

9.62

10.58

9.477.92

5.145.27

9.079.92

9.077.65

5.605.74

2213.77

6.98

3.82

13.48

6.90

4.18

13.02

6.73

4.57

12.44

6.52

5.00

11.77

6.26

5.46

11.03

5.99

5.92

660

1411.67

11.67

3.73

11.27

11.27

4.07

10.85

10.85

4.43

10.38

10.38

4.82

9.89

9.89

5.26

9.38

9.38

5.74

17 1911.92

12.99

11.25

9.31

3.743.83

11.45

12.56

10.99

9.16

4.094.18

10.94

12.01

10.71

8.96

4.454.56

10.39

11.39

10.39

8.70

4.824.97

9.89

10.73

9.898.43

5.265.38

9.37

10.05

9.378.15

5.745.85

2213.88

7.18

3.91

13.64

7.15

4.28

13.20

7.01

4.67

12.63

6.82

5.10

11.96

6.58

5.56

11.21

6.30

6.06

745

1412.01

12.01

3.83

11.62

11.62

4.18

11.17

11.17

4.56

10.68

10.68

4.95

10.17

10.17

5.38

9.63

9.63

5.87

17 1912.12

13.12

11.83

9.74

3.843.92

11.64

12.71

11.64

9.64

4.184.27

11.17

12.16

11.17

9.45

4.564.65

10.68

11.52

10.68

9.20

4.955.07

10.17

10.84

10.17

8.91

5.385.49

9.62

10.15

9.628.62

5.865.95

2213.94

7.36

3.99

13.73

7.37

4.36

13.32

7.27

4.76

12.76

7.10

5.19

12.09

6.87

5.66

11.33

6.59

6.16

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)048

1.02

1.02

FB4BN(F,L)048

1.00

1.00

COILAIR

CONDENSERENTERINGAIRTEMPERATURES˚C

23.89

29.44

3540.56

46.11

51.67

CFM

EWB

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38YCC048--3B,5AOutdoorSectionWithFA4CN(F,C)048IndoorSection

660

1412.97

12.97

3.90

12.49

12.49

4.24

11.99

11.99

4.64

11.47

11.47

5.07

10.90

10.90

5.54

10.28

10.28

6.04

17 1913.39

14.69

12.28

10.26

3.924.01

12.80

14.09

11.97

10.02

4.284.38

12.19

13.41

11.65

9.73

4.664.78

11.56

12.71

11.31

9.44

5.085.22

10.90

11.97

10.90

9.13

5.545.69

10.28

11.16

10.28

8.79

6.046.18

2215.90

8.12

4.10

15.43

7.96

4.48

14.83

7.75

4.90

14.11

7.48

5.36

13.34

7.20

5.85

12.47

6.86

6.38

755

1413.46

13.46

4.02

12.95

12.95

4.38

12.42

12.42

4.78

11.87

11.87

5.21

11.27

11.27

5.69

10.63

10.63

6.19

17 1913.67

14.91

13.08

10.83

4.034.11

13.07

14.33

12.74

10.61

4.394.49

12.44

13.62

12.42

10.34

4.784.89

11.87

12.89

11.87

10.04

5.215.34

11.27

12.13

11.27

9.72

5.695.80

10.63

11.30

10.63

9.38

6.196.29

2216.04

8.38

4.20

15.60

8.26

4.59

15.03

8.08

5.01

14.31

7.83

5.46

13.52

7.55

5.96

12.65

7.22

6.49

850

1413.85

13.85

4.13

13.33

13.33

4.50

12.78

12.78

4.90

12.21

12.21

5.35

11.59

11.59

5.82

10.92

10.92

6.33

17 1913.93

15.07

13.70

11.37

4.154.21

13.34

14.49

13.34

11.19

4.504.59

12.77

13.79

12.77

10.93

4.904.99

12.20

13.03

12.20

10.62

5.355.44

11.59

12.26

11.59

10.29

5.825.92

10.91

11.42

10.91

9.94

6.336.41

2216.13

8.62

4.30

15.72

8.54

4.69

15.16

8.40

5.11

14.45

8.17

5.56

13.66

7.89

6.06

12.79

7.59

6.59

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)060

1.02

1.02

FB4BN(F,L)048

0.98

1.03

FB4BN(F,L)060

1.00

1.06

Seenotesonpage17

38YCC

Page 19: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

19

DETAILEDCOOLINGCAPA

CITIES*

(S.I.)CONTINUED

COILAIR

CONDENSERENTERINGAIRTEMPERATURES˚C

23.89

29.44

3540.56

46.11

51.67

CFM

EWB

Capacity

MBtuh†

Sys.

Power

kW**

CapacityMBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Capacity

MBtuh†

Sys.

Power

kW**

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

Total

Sens‡

38YCC0060--3A,5AOutdoorSectionWithFA4CN(F,C)060IndoorSection

825

1415.66

15.66

4.83

15.09

15.09

5.28

14.51

14.51

5.79

13.91

13.91

6.34

13.26

13.26

6.94

12.56

12.56

7.56

17 1916.17

17.83

14.91

12.47

4.864.92

15.44

17.11

14.52

12.18

5.315.41

14.72

16.22

14.15

11.79

5.815.95

14.00

15.39

13.75

11.45

6.356.49

13.27

14.54

13.27

11.09

6.947.09

12.56

13.64

12.56

10.72

7.567.71

2219.37

9.86

5.01

18.80

9.67

5.50

18.08

9.41

6.04

17.20

9.08

6.63

16.20

8.70

7.27

15.22

8.33

7.92

945

1416.29

16.29

4.97

15.66

15.66

5.46

15.02

15.02

5.96

14.39

14.39

6.52

13.71

13.71

7.12

12.98

12.98

7.75

17 1916.51

18.09

15.91

13.16

4.985.05

15.78

17.38

15.47

12.91

5.475.54

15.03

16.55

15.03

12.58

5.966.08

14.39

15.59

14.39

12.17

6.526.64

13.71

14.72

13.71

11.82

7.127.23

12.98

13.80

12.98

11.43

7.757.86

2219.56

10.19

5.14

19.03

10.04

5.64

18.32

9.81

6.18

17.47

9.52

6.76

16.48

9.16

7.40

15.39

8.75

8.07

1060

1416.78

16.78

5.11

16.17

16.17

5.61

15.45

15.45

6.12

14.78

14.78

6.68

14.07

14.07

7.29

13.32

13.32

7.93

17 1916.79

18.27

16.79

13.81

5.115.18

16.16

17.57

16.16

13.60

5.605.67

15.45

16.75

15.45

13.30

6.126.21

14.77

15.74

14.77

12.87

6.686.78

14.07

14.85

14.07

12.50

7.297.38

13.32

13.92

13.32

12.11

7.938.01

2219.68

10.49

5.27

19.17

10.39

5.77

18.48

10.19

6.31

17.65

9.92

6.90

16.64

9.57

7.53

15.57

9.18

8.21

CoolingIndoorModel

Capacity

Power

*FB4BN(F,L)060

0.99

1.02

NOTE:Whentherequireddatafallbetweenthepublisheddata,interpolationmaybeperformed.Extrapolationisnotanacceptablepractice.

*DetailedcoolingcapacitiesarebasedonindoorandoutdoorunitatthesameelevationperARIstandard210/240---94.Ifadditionaltubinglengthand/orindoorunitislocatedaboveoutdoorunit,aslightvariationincapacitymay

occur.

{Totalandsensiblecapacitiesarenetcapacities.Blowermotorheathasbeensubtracted.

}Sensiblecapacitiesshownarebasedon80˚F(27˚C)enteringairattheindoorcoil.Forsensiblecapacitiesatotherthan80˚F(27˚C),deduct835Btuh(245kW)per1000CFM(480L/S)ofindoorcoilairforeachdegreebelow

80˚F(27˚C),oradd835Btuh(245kW)per1000CFM(480L/S)ofindoorcoilairperdegreeabove80˚F(27˚C).

**UnitkWistotalofindoorandoutdoorunitkilowatts.

EWB---EnteringWetBulb

38YCC

Page 20: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

20

HEATPUMPHEATINGPERFORMANCE(ENGLISH)

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚F

---3

717

2737

4757

67

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Pow er

Capacity

MBtuh

Total

Pow er

Capacity

MBtuh

Total

Pow er

EDB

CFM

Total

Integ†

kW‡

Total

Integ†

kW‡

Total

Integ†

kW‡

Total

Integ†

kW‡

Total

Integ†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC018---3AOutdoorSectionWithFA4CN(F,C)018IndoorSection

65525

7.03

6.47

1.37

9.43

8.67

1.44

11.75

10.72

1.49

14.03

12.46

1.55

16.12

14.67

1.60

18.08

18.08

1.66

20.01

20.01

1.74

21.88

21.88

1.84

600

7.26

6.68

1.41

9.72

8.93

1.47

12.08

11.01

1.52

14.39

12.78

1.57

16.50

15.02

1.62

18.49

18.49

1.68

20.42

20.42

1.75

22.36

22.36

1.84

675

7.48

6.88

1.44

9.95

9.15

1.50

12.36

11.27

1.55

14.70

13.05

1.59

16.82

15.30

1.64

18.82

18.82

1.70

20.75

20.75

1.77

22.59

22.59

1.84

70525

6.37

5.86

1.37

8.84

8.12

1.44

11.18

10.19

1.50

13.49

11.98

1.56

15.63

14.22

1.62

17.58

17.58

1.69

19.50

19.50

1.76

21.35

21.35

1.86

600

6.61

6.08

1.40

9.12

8.38

1.47

11.50

10.49

1.53

13.86

12.31

1.58

16.02

14.57

1.64

18.00

18.00

1.70

19.95

19.95

1.78

21.84

21.84

1.87

675

6.81

6.27

1.44

9.35

8.59

1.50

11.78

10.74

1.56

14.16

12.58

1.61

16.33

14.86

1.66

18.33

18.33

1.72

20.27

20.27

1.79

22.19

22.19

1.88

75525

5.67

5.22

1.36

8.23

7.56

1.44

10.61

9.67

1.51

12.93

11.48

1.57

15.09

13.73

1.64

17.08

17.08

1.71

18.99

18.99

1.78

20.82

20.82

1.88

600

5.88

5.41

1.39

8.50

7.81

1.47

10.91

9.95

1.54

13.30

11.81

1.60

15.51

14.11

1.66

17.50

17.50

1.72

19.43

19.43

1.79

21.34

21.34

1.89

675

6.09

5.60

1.43

8.73

8.02

1.50

11.18

10.19

1.57

13.61

12.09

1.62

15.83

14.41

1.68

17.84

17.84

1.74

19.77

19.77

1.81

21.70

21.70

1.90

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)024

1.01

0.98

FB4BN(F,L)024

1.00

1.00

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚F

‐37

1727

3747

5767

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

CFM

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC024---3AOutdoorSectionWithFA4CN(F,C)024IndoorSection

65700

8.93

8.21

1.53

11.50

10.56

1.63

14.17

12.92

1.72

16.95

15.06

1.82

19.97

18.17

1.94

23.03

23.03

2.05

26.17

26.17

2.17

28.38

28.38

2.25

800

9.16

8.43

1.57

11.74

10.79

1.66

14.47

13.20

1.75

17.29

15.36

1.84

20.31

18.48

1.95

23.51

23.51

2.07

26.04

26.04

2.14

27.82

27.82

2.20

900

9.35

8.60

1.61

11.96

10.99

1.70

14.74

13.44

1.78

17.58

15.61

1.87

20.68

18.82

1.98

23.70

23.70

2.07

25.69

25.69

2.13

27.16

27.16

2.17

70700

8.48

7.80

1.54

11.05

10.16

1.65

13.71

12.50

1.75

16.51

14.66

1.85

19.47

17.72

1.97

22.49

22.49

2.09

25.81

25.81

2.23

28.26

28.26

2.32

800

8.70

8.00

1.58

11.31

10.39

1.68

14.00

12.76

1.78

16.81

14.93

1.87

19.87

18.08

1.99

23.00

23.00

2.11

25.88

25.88

2.21

27.81

27.81

2.27

900

8.90

8.18

1.62

11.53

10.59

1.72

14.26

13.00

1.81

17.16

15.24

1.91

20.12

18.31

2.00

23.32

23.32

2.12

25.67

25.67

2.19

27.28

27.28

2.24

75700

8.02

7.38

1.56

10.61

9.75

1.67

13.28

12.11

1.78

16.05

14.25

1.89

18.98

17.27

2.01

21.97

21.97

2.13

25.36

25.36

2.28

28.01

28.01

2.39

800

8.23

7.57

1.60

10.86

9.98

1.70

13.55

12.36

1.81

16.35

14.52

1.91

19.31

17.57

2.02

22.46

22.46

2.15

25.60

25.60

2.26

27.73

27.73

2.34

900

8.43

7.76

1.63

11.07

10.18

1.74

13.79

12.58

1.84

16.66

14.79

1.94

19.62

17.86

2.04

22.81

22.81

2.17

25.55

25.55

2.25

27.31

27.31

2.31

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)030

1.01

1.01

FB4BN(F,L)024

0.99

1.03

Seenotesonpage23

38YCC

Page 21: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

21

HEATPUMPHEATINGPERFORMANCE(ENGLISH)CONTINUED

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚F

‐37

1727

3747

5767

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

CFM

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC030---3AOutdoorSectionWithFA4CN(F,C)030IndoorSection

65875

11.02

10.14

2.04

14.28

13.12

2.15

17.69

16.13

2.26

21.31

18.93

2.36

25.17

22.90

2.48

29.33

29.33

2.60

33.96

33.96

2.75

37.86

37.86

2.85

1000

11.30

10.39

2.09

14.59

13.41

2.20

18.05

16.46

2.30

21.70

19.27

2.39

25.63

23.33

2.50

29.92

29.92

2.63

34.16

34.16

2.73

37.24

37.24

2.80

1125

11.54

10.62

2.14

14.87

13.66

2.24

18.37

16.75

2.34

22.07

19.60

2.43

26.02

23.68

2.53

30.33

30.33

2.65

33.95

33.95

2.72

36.51

36.51

2.77

70875

10.45

9.62

2.05

13.72

12.61

2.17

17.13

15.62

2.29

20.76

18.44

2.40

24.56

22.35

2.52

28.68

28.68

2.65

33.27

33.27

2.81

37.60

37.60

2.93

1000

10.72

9.87

2.10

14.02

12.89

2.22

17.50

15.96

2.33

21.18

18.81

2.44

25.03

22.77

2.55

29.20

29.20

2.67

33.74

33.74

2.80

37.17

37.17

2.88

1125

10.97

10.09

2.16

14.31

13.15

2.27

17.81

16.24

2.37

21.51

19.10

2.47

25.41

23.13

2.58

29.69

29.69

2.70

33.74

33.74

2.80

36.59

36.59

2.85

75875

9.87

9.08

2.07

13.17

12.10

2.20

16.58

15.12

2.32

20.19

17.93

2.44

24.00

21.84

2.57

28.03

28.03

2.71

32.52

32.52

2.86

37.14

37.14

3.01

1000

10.13

9.32

2.12

13.46

12.37

2.24

16.93

15.43

2.36

20.59

18.29

2.48

24.43

22.23

2.59

28.55

28.55

2.72

33.19

33.19

2.87

36.99

36.99

2.97

1125

10.38

9.55

2.17

13.73

12.62

2.29

17.24

15.72

2.40

20.95

18.60

2.51

24.81

22.58

2.62

28.98

28.98

2.75

33.41

33.41

2.87

36.55

36.55

2.94

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)036

1.01

1.01

FB4BN(F,L)036

1.00

1.03

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚F

‐37

1727

3747

5767

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

CFM

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC036---3A,5AOutdoorSectionWithFA4CN(F,C)036IndoorSection

651050

13.86

12.75

2.41

17.86

16.41

2.56

22.00

20.06

2.69

26.38

23.43

2.84

30.91

28.13

3.00

35.76

35.76

3.17

41.29

41.29

3.39

46.11

46.11

3.56

1200

14.23

13.09

2.48

18.28

16.80

2.62

22.46

20.48

2.75

26.92

23.91

2.89

31.49

28.66

3.04

36.43

36.43

3.22

41.53

41.53

3.38

45.51

45.51

3.52

1350

14.56

13.40

2.55

18.64

17.13

2.68

22.86

20.84

2.80

27.32

24.27

2.94

31.94

29.06

3.09

36.87

36.87

3.26

41.42

41.42

3.39

44.91

44.91

3.50

701050

13.14

12.09

2.42

17.19

15.79

2.58

21.40

19.51

2.73

25.73

22.86

2.88

30.30

27.57

3.05

35.06

35.06

3.23

40.59

40.59

3.47

45.80

45.80

3.65

1200

13.50

12.42

2.49

17.59

16.17

2.64

21.80

19.88

2.78

26.21

23.28

2.93

30.83

28.05

3.09

35.60

35.60

3.26

41.07

41.07

3.46

45.43

45.43

3.61

1350

13.84

12.73

2.56

17.98

16.52

2.70

22.21

20.25

2.84

26.63

23.66

2.98

31.28

28.47

3.14

36.20

36.20

3.32

41.15

41.15

3.47

44.94

44.94

3.60

751050

12.39

11.40

2.43

16.50

15.17

2.60

20.73

18.90

2.76

25.03

22.23

2.92

29.68

27.00

3.10

34.36

34.36

3.29

39.74

39.74

3.52

45.39

45.39

3.74

1200

12.75

11.73

2.50

16.91

15.54

2.66

21.17

19.30

2.82

25.53

22.68

2.97

30.19

27.47

3.14

34.91

34.91

3.31

40.43

40.43

3.54

45.25

45.25

3.71

1350

13.09

12.04

2.56

17.26

15.86

2.72

21.57

19.66

2.87

25.97

23.06

3.02

30.63

27.88

3.19

35.47

35.47

3.37

40.75

40.75

3.55

44.88

44.88

3.69

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)042

1.02

1.02

FB4BN(F,L)036

1.01

1.04

Seenotesonpage23

38YCC

Page 22: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

22

HEATPUMPHEATINGPERFORMANCE(ENGLISH)CONTINUED

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚F

–37

1727

3747

5767

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

CFM

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC042---3B,5AOutdoorSectionWithFA4CN(F,C)042IndoorSection

651225

18.88

17.37

3.06

22.73

20.89

3.16

26.96

24.58

3.29

31.50

27.98

3.44

36.58

33.28

3.62

42.18

42.18

3.86

48.61

48.61

4.16

55.94

55.94

4.54

1400

19.21

17.67

3.11

23.07

21.20

3.19

27.33

24.91

3.31

31.89

28.32

3.45

37.01

33.68

3.63

42.65

42.65

3.85

49.15

49.15

4.14

56.55

56.55

4.51

1575

19.51

17.95

3.16

23.40

21.50

3.24

27.66

25.22

3.35

32.24

28.63

3.48

37.38

34.01

3.65

43.05

43.05

3.87

49.58

49.58

4.16

56.77

56.77

4.47

701225

18.54

17.06

3.18

22.43

20.61

3.29

26.63

24.28

3.42

31.17

27.68

3.58

36.18

32.93

3.77

41.72

41.72

4.00

48.07

48.07

4.30

55.30

55.30

4.69

1400

18.87

17.36

3.22

22.77

20.92

3.32

27.00

24.62

3.44

31.55

28.02

3.59

36.61

33.32

3.76

42.20

42.20

3.99

48.62

48.62

4.28

55.89

55.89

4.65

1575

19.18

17.65

3.28

23.08

21.21

3.37

27.34

24.92

3.48

31.90

28.33

3.61

36.99

33.66

3.79

42.60

42.60

4.01

49.06

49.06

4.29

56.42

56.42

4.66

751225

18.16

16.71

3.29

22.11

20.32

3.42

26.28

23.96

3.55

30.79

27.35

3.71

35.80

32.57

3.91

41.27

41.27

4.15

47.53

47.53

4.46

54.66

54.66

4.85

1400

18.50

17.02

3.34

22.45

20.63

3.45

26.66

24.30

3.57

31.22

27.73

3.73

36.22

32.96

3.91

41.75

41.75

4.14

48.09

48.09

4.43

55.28

55.28

4.80

1575

18.81

17.31

3.40

22.77

20.93

3.50

27.00

24.61

3.61

31.57

28.04

3.75

36.60

33.31

3.93

42.16

42.16

4.15

48.54

48.54

4.44

55.82

55.82

4.80

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)048

1.00

0.97

FB4BN(F,L)048

1.00

1.00

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚F

–37

1727

3747

5767

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

CFM

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC048---3B,5AOutdoorSectionWithFA4CN(F,C)048IndoorSection

651400

21.20

19.51

3.52

25.54

23.47

3.60

30.16

27.50

3.67

35.16

31.23

3.77

40.80

37.13

3.88

46.95

46.95

4.03

54.08

54.08

4.22

62.19

62.19

4.48

1600

21.59

19.86

3.58

25.94

23.83

3.64

30.59

27.89

3.70

35.64

31.66

3.78

41.32

37.60

3.89

47.54

47.54

4.02

54.76

54.76

4.20

62.21

62.21

4.35

1800

21.95

20.19

3.65

26.30

24.17

3.70

30.98

28.25

3.75

36.05

32.02

3.82

41.77

38.01

3.91

48.03

48.03

4.03

55.28

55.28

4.22

61.63

61.63

4.28

701400

20.76

19.10

3.65

25.17

23.13

3.74

29.79

27.16

3.82

34.75

30.86

3.92

40.33

36.70

4.04

46.41

46.41

4.19

53.44

53.44

4.38

61.42

61.42

4.65

1600

21.16

19.46

3.71

25.56

23.49

3.78

30.20

27.54

3.85

35.21

31.27

3.93

40.85

37.17

4.04

47.00

47.00

4.17

54.12

54.12

4.36

61.92

61.92

4.55

1800

21.52

19.80

3.78

25.93

23.83

3.84

30.59

27.89

3.89

35.62

31.64

3.96

41.30

37.58

4.06

47.49

47.49

4.18

54.67

54.67

4.36

61.80

61.80

4.48

751400

20.30

18.67

3.78

24.75

22.75

3.88

29.43

26.83

3.97

34.34

30.50

4.08

39.87

36.28

4.20

45.88

45.88

4.35

52.80

52.80

4.55

60.65

60.65

4.81

1600

20.68

19.03

3.84

25.16

23.12

3.93

29.84

27.21

4.00

34.80

30.91

4.09

40.38

36.75

4.20

46.47

46.47

4.33

53.49

53.49

4.52

61.45

61.45

4.75

1800

21.03

19.35

3.91

25.54

23.47

3.98

30.22

27.56

4.04

35.21

31.27

4.12

40.83

37.16

4.22

46.96

46.96

4.34

54.03

54.03

4.52

61.57

61.57

4.67

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)060

1.00

1.00

FB4BN(F,L)048

1.00

1.03

FB4BN(F,L)060

1.01

1.04

Seenotesonpage23

38YCC

Page 23: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

23

HEATPUMPHEATINGPERFORMANCE(ENGLISH)CONTINUED

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚F

–37

1727

3747

5767

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

CFM

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC060---3A,,5AOutdoorSectionWithFA4CN(F,C)060IndoorSection

651750

27.84

25.62

4.25

33.02

30.34

4.35

38.35

34.97

4.47

44.45

39.48

4.62

51.14

46.54

4.81

58.24

58.24

4.99

64.02

64.02

5.12

68.78

68.78

5.25

2000

28.34

26.07

4.33

33.51

30.80

4.41

38.88

35.45

4.52

45.02

39.98

4.65

51.79

47.13

4.83

57.90

57.90

4.92

62.38

62.38

5.01

66.28

66.28

5.08

2250

28.81

26.51

4.41

33.98

31.23

4.49

39.37

35.89

4.58

45.54

40.44

4.71

52.32

47.61

4.84

57.03

57.03

4.90

60.77

60.77

4.95

63.94

63.94

4.99

701750

27.40

25.21

4.41

32.66

30.01

4.53

37.97

34.62

4.66

43.99

39.07

4.81

50.63

46.08

5.01

57.78

57.78

5.23

64.28

64.28

5.37

69.33

69.33

5.51

2000

27.91

25.68

4.49

33.16

30.48

4.59

38.50

35.10

4.70

44.59

39.60

4.84

51.27

46.65

5.02

58.00

58.00

5.15

62.93

62.93

5.25

67.12

67.12

5.34

2250

28.39

26.12

4.58

33.64

30.91

4.66

38.99

35.55

4.76

45.11

40.06

4.89

51.85

47.19

5.06

57.48

57.48

5.12

61.53

61.53

5.19

64.99

64.99

5.24

751750

26.91

24.76

4.57

32.26

29.65

4.71

37.63

34.31

4.85

43.55

38.68

5.01

50.13

45.62

5.22

57.17

57.17

5.46

64.31

64.31

5.62

69.73

69.73

5.79

2000

27.43

25.24

4.65

32.78

30.12

4.77

38.14

34.77

4.89

44.12

39.18

5.04

50.75

46.18

5.22

57.78

57.78

5.39

63.34

63.34

5.50

67.79

67.79

5.61

2250

27.90

25.67

4.74

33.26

30.56

4.84

38.61

35.21

4.95

44.64

39.65

5.08

51.33

46.71

5.26

57.68

57.68

5.36

62.16

62.16

5.44

65.89

65.89

5.50

CoolingIndoorModel

Capacity

Power

*FB4BN(F,L)060

1.00

1.03

NOTE:Whentherequireddatafallbetweenthepublisheddata,interpolationmaybeperformed.Extrapolationisnotanacceptablepractice.

*TheBtuhheatingcapacityvaluesshownarenet“integrated”valuesfromwhichthedefrosteffecthasbeensubtracted.TheBtuhheatingfromsupplementheatersshouldbeaddedtothosevaluestoobtaintotalsystemcapacity.

{ThekWvaluesincludethecompressor,outdoorfanmotor,andindoorblowermotor.ThekWfromsupplementheatersshouldbeaddedtothesevaluestoobtaintotalsystemkilowatts.

EDB=EnteringDryBulb

38YCC

Page 24: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

24

HEATPUMPHEATINGPERFORMANCE(S.I.)

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚C

–19.44

---13.89

---8.33

---2.78

2.78

8.33

13.89

19.44

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

L/S

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC018---3AOutdoorSectionWithFA4CN(F,C)018IndoorSection

18250

2.06

1.89

1.37

2.76

2.54

1.44

3.44

3.14

1.49

4.11

3.65

1.55

4.72

4.30

1.60

5.30

5.30

1.66

5.86

5.86

1.74

6.41

6.41

1.84

285

2.13

1.96

1.41

2.85

2.62

1.47

3.54

3.23

1.52

4.22

3.75

1.57

4.84

4.40

1.62

5.42

5.42

1.68

5.98

5.98

1.75

6.55

6.55

1.84

320

2.19

2.02

1.44

2.92

2.68

1.50

3.62

3.30

1.55

4.31

3.82

1.59

4.93

4.48

1.64

5.51

5.51

1.70

6.08

6.08

1.77

6.62

6.62

1.84

21250

1.87

1.72

1.37

2.59

2.38

1.44

3.28

2.99

1.50

3.95

3.51

1.56

4.58

4.17

1.62

5.15

5.15

1.69

5.71

5.71

1.76

6.26

6.26

1.86

285

1.94

1.78

1.40

2.67

2.45

1.47

3.37

3.07

1.53

4.06

3.61

1.58

4.69

4.27

1.64

5.27

5.27

1.70

5.85

5.85

1.78

6.40

6.40

1.87

320

2.00

1.84

1.44

2.74

2.52

1.50

3.45

3.15

1.56

4.15

3.69

1.61

4.78

4.35

1.66

5.37

5.37

1.72

5.94

5.94

1.79

6.50

6.50

1.88

24250

1.66

1.53

1.36

2.41

2.22

1.44

3.11

2.83

1.51

3.79

3.36

1.57

4.42

4.02

1.64

5.01

5.01

1.71

5.56

5.56

1.78

6.10

6.10

1.88

285

1.72

1.59

1.39

2.49

2.29

1.47

3.20

2.91

1.54

3.90

3.46

1.60

4.54

4.13

1.66

5.13

5.13

1.72

5.69

5.69

1.79

6.25

6.25

1.89

320

1.78

1.64

1.43

2.56

2.35

1.50

3.28

2.99

1.57

3.99

3.54

1.62

4.64

4.22

1.68

5.23

5.23

1.74

5.79

5.79

1.81

6.36

6.36

1.90

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)024

1.01

0.98

FB4BN(F,L)024

1.00

1.00

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚C

–19.44

---13.89

---8.33

---2.78

2.78

8.33

13.89

19.44

INDOOR

AIR

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

L/S

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC024---3AOutdoorSectionWithFA4CN(F,C)024IndoorSection

18330

2.62

2.41

1.53

3.37

3.10

1.63

4.15

3.79

1.72

4.97

4.41

1.82

5.85

5.32

1.94

6.75

6.75

2.05

7.67

7.67

2.17

8.32

8.32

2.25

380

2.68

2.47

1.57

3.44

3.16

1.66

4.24

3.87

1.75

5.07

4.50

1.84

5.95

5.42

1.95

6.89

6.89

2.07

7.63

7.63

2.14

8.15

8.15

2.20

425

2.74

2.52

1.61

3.50

3.22

1.70

4.32

3.94

1.78

5.15

4.57

1.87

6.06

5.51

1.98

6.94

6.94

2.07

7.53

7.53

2.13

7.96

7.96

2.17

21330

2.48

2.29

1.54

3.24

2.98

1.65

4.02

3.66

1.75

4.84

4.30

1.85

5.70

5.19

1.97

6.59

6.59

2.09

7.56

7.56

2.23

8.28

8.28

2.32

380

2.55

2.34

1.58

3.31

3.04

1.68

4.10

3.74

1.78

4.93

4.37

1.87

5.82

5.30

1.99

6.74

6.74

2.11

7.58

7.58

2.21

8.15

8.15

2.27

425

2.61

2.40

1.62

3.38

3.10

1.72

4.18

3.81

1.81

5.03

4.47

1.91

5.89

5.36

2.00

6.83

6.83

2.12

7.52

7.52

2.19

7.99

7.99

2.24

24330

2.35

2.16

1.56

3.11

2.86

1.67

3.89

3.55

1.78

4.70

4.18

1.89

5.56

5.06

2.01

6.44

6.44

2.13

7.43

7.43

2.28

8.21

8.21

2.39

380

2.41

2.22

1.60

3.18

2.92

1.70

3.97

3.62

1.81

4.79

4.26

1.91

5.66

5.15

2.02

6.58

6.58

2.15

7.50

7.50

2.26

8.13

8.13

2.34

425

2.47

2.27

1.63

3.24

2.98

1.74

4.04

3.68

1.84

4.88

4.33

1.94

5.75

5.23

2.04

6.68

6.68

2.17

7.49

7.49

2.25

8.00

8.00

2.31

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)030

1.01

1.01

FB4BN(F,L)024

0.99

1.03

Seenotesonpage27

38YCC

Page 25: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

25

HEATPUMPHEATINGPERFORMANCE(S.I.)CONTINUED

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚C

–19.44

---13.89

---8.33

---2.78

2.78

8.33

13.89

19.44

INDOOR

AIR

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

L/S

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC030---3AOutdoorSectionWithFA4CN(F,C)030IndoorSection

18415

3.23

2.97

2.04

4.18

3.84

2.15

5.18

4.73

2.26

6.24

5.55

2.36

7.37

6.71

2.48

8.59

8.59

2.60

9.95

9.95

2.75

11.09

11.09

2.85

470

3.31

3.05

2.09

4.27

3.93

2.20

5.29

4.82

2.30

6.36

5.65

2.39

7.51

6.83

2.50

8.77

8.77

2.63

10.01

10.01

2.73

10.91

10.91

2.80

530

3.38

3.11

2.14

4.36

4.00

2.24

5.38

4.91

2.34

6.47

5.74

2.43

7.62

6.94

2.53

8.89

8.89

2.65

9.95

9.95

2.72

10.70

10.70

2.77

21415

3.06

2.82

2.05

4.02

3.69

2.17

5.02

4.58

2.29

6.08

5.40

2.40

7.20

6.55

2.52

8.40

8.40

2.65

9.75

9.75

2.81

11.02

11.02

2.93

470

3.14

2.89

2.10

4.11

3.78

2.22

5.13

4.68

2.33

6.20

5.51

2.44

7.33

6.67

2.55

8.56

8.56

2.67

9.88

9.88

2.80

10.89

10.89

2.88

530

3.21

2.96

2.16

4.19

3.85

2.27

5.22

4.76

2.37

6.30

5.60

2.47

7.45

6.78

2.58

8.70

8.70

2.70

9.89

9.89

2.80

10.72

10.72

2.85

24415

2.89

2.66

2.07

3.86

3.54

2.20

4.86

4.43

2.32

5.91

5.25

2.44

7.03

6.40

2.57

8.21

8.21

2.71

9.53

9.53

2.86

10.88

10.88

3.01

470

2.97

2.73

2.12

3.94

3.62

2.24

4.96

4.52

2.36

6.03

5.36

2.48

7.16

6.51

2.59

8.37

8.37

2.72

9.72

9.72

2.87

10.84

10.84

2.97

530

3.04

2.80

2.17

4.02

3.70

2.29

5.05

4.60

2.40

6.14

5.45

2.51

7.27

6.62

2.62

8.49

8.49

2.75

9.79

9.79

2.87

10.71

10.71

2.94

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)036

1.01

1.01

FB4BN(F,L)036

1.00

1.03

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚C

–19.44

---13.89

---8.33

---2.78

2.78

8.33

13.89

19.44

INDOOR

AIR

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

L/S

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC036---3A,5AOutdoorSectionWithFA4CN(F,C)036IndoorSection

18495

4.06

3.74

2.41

5.23

4.81

2.56

6.45

5.88

2.69

7.73

6.87

2.84

9.06

8.24

3.00

10.48

10.48

3.17

12.10

12.10

3.39

13.51

13.51

3.56

565

4.17

3.84

2.48

5.36

4.92

2.62

6.58

6.00

2.75

7.89

7.01

2.89

9.23

8.40

3.04

10.67

10.67

3.22

12.17

12.17

3.38

13.34

13.34

3.52

635

4.27

3.93

2.55

5.46

5.02

2.68

6.70

6.11

2.80

8.01

7.11

2.94

9.36

8.52

3.09

10.80

10.80

3.26

12.14

12.14

3.39

13.16

13.16

3.50

21495

3.85

3.54

2.42

5.04

4.63

2.58

6.27

5.72

2.73

7.54

6.70

2.88

8.88

8.08

3.05

10.27

10.27

3.23

11.89

11.89

3.47

13.42

13.42

3.65

565

3.96

3.64

2.49

5.16

4.74

2.64

6.39

5.82

2.78

7.68

6.82

2.93

9.03

8.22

3.09

10.43

10.43

3.26

12.03

12.03

3.46

13.31

13.31

3.61

635

4.05

3.73

2.56

5.27

4.84

2.70

6.51

5.93

2.84

7.80

6.93

2.98

9.17

8.34

3.14

10.61

10.61

3.32

12.06

12.06

3.47

13.17

13.17

3.60

24495

3.63

3.34

2.43

4.84

4.44

2.60

6.07

5.54

2.76

7.33

6.51

2.92

8.69

7.91

3.10

10.07

10.07

3.29

11.64

11.64

3.52

13.30

13.30

3.74

565

3.74

3.44

2.50

4.95

4.55

2.66

6.20

5.65

2.82

7.48

6.64

2.97

8.84

8.05

3.14

10.23

10.23

3.31

11.85

11.85

3.54

13.26

13.26

3.71

635

3.83

3.53

2.56

5.06

4.65

2.72

6.32

5.76

2.87

7.61

6.76

3.02

8.98

8.17

3.19

10.39

10.39

3.37

11.94

11.94

3.55

13.15

13.15

3.69

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)042

1.02

1.02

FB4BN(F,L)036

1.01

1.04

Seenotesonpage27

38YCC

Page 26: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

26

HEATPUMPHEATINGPERFORMANCE(S.I.)CONTINUED

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚C

–19.44

---13.89

---8.33

---2.78

2.78

8.33

13.89

19.44

INDOOR

AIR

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

L/S

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC042---3B,5AOutdoorSectionWithFA4CN(F,C)042IndoorSection

18580

5.53

5.09

3.06

6.66

6.12

3.16

7.90

7.20

3.29

9.23

8.20

3.44

10.72

9.75

3.62

12.36

12.36

3.86

14.24

14.24

4.16

16.39

16.39

4.54

660

5.63

5.18

3.11

6.76

6.21

3.19

8.01

7.30

3.31

9.34

8.30

3.45

10.84

9.87

3.63

12.50

12.50

3.85

14.40

14.40

4.14

16.57

16.57

4.51

745

5.72

5.26

3.16

6.86

6.30

3.24

8.10

7.39

3.35

9.45

8.39

3.48

10.95

9.97

3.65

12.61

12.61

3.87

14.53

14.53

4.16

16.63

16.63

4.47

580

5.43

5.00

3.18

6.57

6.04

3.29

7.80

7.11

3.42

9.13

8.11

3.58

10.60

9.65

3.77

12.22

12.22

4.00

14.08

14.08

4.30

16.20

16.20

4.69

21660

5.53

5.09

3.22

6.67

6.13

3.32

7.91

7.21

3.44

9.24

8.21

3.59

10.73

9.76

3.76

12.36

12.36

3.99

14.24

14.24

4.28

16.38

16.38

4.65

745

5.62

5.17

3.28

6.76

6.22

3.37

8.01

7.30

3.48

9.35

8.30

3.61

10.84

9.86

3.79

12.48

12.48

4.01

14.37

14.37

4.29

16.53

16.53

4.66

24580

5.32

4.90

3.29

6.48

5.95

3.42

7.70

7.02

3.55

9.02

8.01

3.71

10.49

9.54

3.91

12.09

12.09

4.15

13.93

13.93

4.46

16.02

16.02

4.85

660

5.42

4.99

3.34

6.58

6.05

3.45

7.81

7.12

3.57

9.15

8.12

3.73

10.61

9.66

3.91

12.23

12.23

4.14

14.09

14.09

4.43

16.20

16.20

4.80

745

5.51

5.07

3.40

6.67

6.13

3.50

7.91

7.21

3.61

9.25

8.21

3.75

10.72

9.76

3.93

12.35

12.35

4.15

14.22

14.22

4.44

16.35

16.35

4.80

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)048

1.00

0.97

FB4BN(F,L)048

1.00

1.00

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚C

–19.44

---13.89

---8.33

---2.78

2.78

8.33

13.89

19.44

INDOORAIR

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

L/S

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC048---3B,5AOutdoorSectionWithFA4CN(F,C)048IndoorSection

18660

6.21

5.72

3.52

7.48

6.88

3.60

8.84

8.06

3.67

10.30

9.15

3.77

11.95

10.88

3.88

13.76

13.76

4.03

15.84

15.84

4.22

18.22

18.22

4.48

755

6.33

5.82

3.58

7.60

6.98

3.64

8.96

8.17

3.70

10.44

9.28

3.78

12.11

11.02

3.89

13.93

13.93

4.02

16.04

16.04

4.20

18.23

18.23

4.35

850

6.43

5.92

3.65

7.71

7.08

3.70

9.08

8.28

3.75

10.56

9.38

3.82

12.24

11.14

3.91

14.07

14.07

4.03

16.20

16.20

4.22

18.06

18.06

4.28

21660

6.08

5.60

3.65

7.37

6.78

3.74

8.73

7.96

3.82

10.18

9.04

3.92

11.82

10.75

4.04

13.60

13.60

4.19

15.66

15.66

4.38

17.99

17.99

4.65

755

6.20

5.70

3.71

7.49

6.88

3.78

8.85

8.07

3.85

10.32

9.16

3.93

11.97

10.89

4.04

13.77

13.77

4.17

15.86

15.86

4.36

18.14

18.14

4.55

850

6.31

5.80

3.78

7.60

6.98

3.84

8.96

8.17

3.89

10.44

9.27

3.96

12.10

11.01

4.06

13.92

13.92

4.18

16.02

16.02

4.36

18.11

18.11

4.48

24660

5.95

5.47

3.78

7.25

6.66

3.88

8.62

7.86

3.97

10.06

8.94

4.08

11.68

10.63

4.20

13.44

13.44

4.35

15.47

15.47

4.55

17.77

17.77

4.81

755

6.06

5.58

3.84

7.37

6.77

3.93

8.74

7.97

4.00

10.20

9.06

4.09

11.83

10.77

4.20

13.61

13.61

4.33

15.67

15.67

4.52

18.00

18.00

4.75

850

6.16

5.67

3.91

7.48

6.88

3.98

8.86

8.07

4.04

10.32

9.16

4.12

11.96

10.89

4.22

13.76

13.76

4.34

15.83

15.83

4.52

18.04

18.04

4.67

CoolingIndoorModel

Capacity

Power

*FA4CN(F,C)060

1.00

1.00

FB4BN(F,L)048

1.00

1.03

FB4BN(F,L)060

1.01

1.04

Seenotesonpage27

38YCC

Page 27: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

27

HEATPUMPHEATINGPERFORMANCE(S.I.)CONTINUED

INDOOR

AIR

OUTDOORCOILENTERINGAIRTEMPERATURES˚C

–19.44

---13.89

---8.33

---2.78

2.78

8.33

13.89

19.44

INDOOR

AIR

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

Capacity

MBtuh

Total

Power

EDB

L/S

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

Total

In-

teg†

kW‡

38YCC060---3A,5AOutdoorSectionWithFA4CN(F,C)060IndoorSection

18825

8.16

7.51

4.25

9.67

8.89

4.35

11.24

10.25

4.47

13.02

11.57

4.62

14.98

13.64

4.81

17.06

17.06

4.99

18.76

18.76

5.12

20.15

20.15

5.25

945

8.30

7.64

4.33

9.82

9.02

4.41

11.39

10.39

4.52

13.19

11.71

4.65

15.17

13.81

4.83

16.96

16.96

4.92

18.28

18.28

5.01

19.42

19.42

5.08

1060

8.44

7.77

4.41

9.96

9.15

4.49

11.53

10.52

4.58

13.34

11.85

4.71

15.33

13.95

4.84

16.71

16.71

4.90

17.81

17.81

4.95

18.73

18.73

4.99

21825

8.03

7.39

4.41

9.57

8.79

4.53

11.13

10.14

4.66

12.89

11.45

4.81

14.84

13.50

5.01

16.93

16.93

5.23

18.84

18.84

5.37

20.31

20.31

5.51

945

8.18

7.52

4.49

9.72

8.93

4.59

11.28

10.29

4.70

13.06

11.60

4.84

15.02

13.67

5.02

16.99

16.99

5.15

18.44

18.44

5.25

19.66

19.66

5.34

1060

8.32

7.65

4.58

9.86

9.06

4.66

11.42

10.42

4.76

13.22

11.74

4.89

15.19

13.83

5.06

16.84

16.84

5.12

18.03

18.03

5.19

19.04

19.04

5.24

24825

7.89

7.25

4.57

9.45

8.69

4.71

11.03

10.05

4.85

12.76

11.33

5.01

14.69

13.37

5.22

16.75

16.75

5.46

18.84

18.84

5.62

20.43

20.43

5.79

945

8.04

7.39

4.65

9.60

8.83

4.77

11.17

10.19

4.89

12.93

11.48

5.04

14.87

13.53

5.22

16.93

16.93

5.39

18.56

18.56

5.50

19.86

19.86

5.61

1060

8.17

7.52

4.74

9.75

8.96

4.84

11.31

10.32

4.95

13.08

11.62

5.08

15.04

13.69

5.26

16.90

16.90

5.36

18.21

18.21

5.44

19.30

19.30

5.50

CoolingIndoorModel

Capacity

Power

*FB4BN(F,L)060

1.00

1.03

NOTE:Whentherequireddatafallbetweenthepublisheddata,interpolationmaybeperformed.Extrapolationisnotanacceptablepractice.

{TheBtuhheatingcapacityvaluesshownarenetintegratedvaluesfromwhichthedefrosteffecthasbeensubtracted.TheBtuhheatingfromsupplementheatersshouldbeaddedtothosevaluestoobtaintotalsystemcapacity.

}ThekWvaluesincludethecompressor,outdoorfanmotor,andindoorblowermotor.ThekWfromsupplementheatersshouldbeaddedtothesevaluestoobtaintotalsystemkilowatts.

EDB---EnteringDryBulb

SYST

EM

DESIGN

1.Intended

foroutdoorinstallationwith

freeairinletand

outlet.Outdoorfanexternalstaticpressureavailableislessthan

0.01--in.wc.

2.Minimum

outdooroperatingairtemperatureforcoolingmodewithoutlow

--ambientoperationaccessoryis55_F(12.8_C).

3.Maximum

outdooroperatingairtemperatureforcoolingmodeis125_F(51.7_C).

4.Minimum

outdooroperatingairtemperatureforheatingmodeis--30_F(--34.4_C).

5.Maximum

outdooroperatingairtemperatureforheatingmodeis66_F(18.9_C).

6.Forreliableoperation,unitshouldbe

levelinallhorizontalplanes.

7.Maximum

elevationofindoorcoilaboveorbelowbaseofoutdoorunitis:indoorcoilabove=50

ft(15.24m),indoorcoilbelow=150ft(45.72m).(Seeitems8and9following.)

8.Forinterconnectingrefrigeranttube

lengthsbetween50

(15.24)and175ft(53.3m

)and/or

20ft(6.1m)verticaldifferential,consulttheResidentialSplit--SystemLong--LineApplicationGuideline

availablefrom

equipm

entdistributor.

9.Ifanyrefrigeranttubing

isburied,provide

aminimum

6--in.(152mm)verticalrisetothevalveconnectionsattheunit.Refrigeranttubing

lengthsup

to36

in.(912m

m).may

beburied

withoutfurther

consideration.Forburied

refrigeranttubinglengthsgreaterthan

36in.(912m

m),consultyourlocaldistributor.

10.Useonlycopperwireforelectricconnectionatunit.Aluminum

andclad

alum

inum

arenotacceptableforthetype

ofconnectorprovided.

11.M

ismatchesofindoorcoilcapacitymorethan

1sizelargerthan

outdoorunitcapacitymay

resultininadequateindoorcomfort.

38YCC

Page 28: Product Data · 2013-12-31 · 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes 18 --- 60 (1---1/2 to 5 Nominal Tons) Product Data The 38YCC Outdoor Section of Split--System Heat

28

GUIDE SPECIFICATIONSGENERALSystem DescriptionOutdoor--mounted, air--cooled, split--system heat pump unitsuitable for ground or rooftop installation. Unit consists of ahermetic compressor, an air--cooled coil, propeller--type condenserfan, and a control box. Unit will discharge supply air upward asshown on contract drawings. Unit will be used in a refrigerationcircuit to match up to a packaged fan coil or coil unit.Quality Assurance

— Unit construction will comply with latest edition ofANSI/ASHRAE and with NEC.

— Unit will be constructed in accordance with ULstandards and will carry the UL label of approval. Unitwill have c--UL approval.

— Unit cabinet will be capable of withstanding Federal TestMethod Standard No. 141 (Method 6061) 500--hr saltspray test.

— Air--cooled condenser coils will be leak tested at 150psig and pressure tested at 300 psig.

— Unit constructed in ISO 9001 approved facility.

Delivery, Storage, and Handling— Unit will be shipped as single package only and is stored

and handled per unit manufacturer’s recommendations.

PRODUCTSEquipment

— Factory--assembled, single--piece, air--cooled heat pumpunit. Contained within the unit enclosure is all factorywiring, piping, controls, compressor, refrigerant charge(R22), and special features required prior to fieldstart--up.

Unit Cabinet

— Unit cabinet will be constructed of galvanized,prepainted steel.

Fans— Condenser fan will be direct--drive propeller type,

discharging air upward.

AIR--COOLED, SPLIT--SYSTEM HEAT PUMP38YCC

1--1/2 TO 5 NOMINAL TONS— Condenser fan motors will be totally enclosed, 1--phase

type with class B insulation and permanently lubricatedbearings. Shafts will be corrosion resistant.

— Fan blades will be statically and dynamically balanced.

— Condenser fan openings will be equipped with coatedsteel wire safety guards.

Compressor— Compressor will be hermetically sealed.

— Compressor will be mounted on rubber vibrationisolators.

Condenser Coil— Condenser coil will be air cooled.

— Coil will be constructed of epoxy coated, enhancedaluminum fins mechanically bonded to copper tubeswhich are then cleaned, dehydrated, and sealed.

Refrigeration Components

— Refrigeration circuit components will include liquid lineshutoff valve with sweat connections, suction line shutoffvalves with sweat connections, system charge of R--22refrigerant, and compressor oil.

Operating Characteristics— The capacity of the unit will meet or exceed _____ Btuh

at a suction temperature of _____ _F (_C). The powerconsumption at full load will not exceed _____ kW.

— Combination of the unit and the evaporator or fan coilunit will have a total net cooling capacity of _____ Btuhor greater at conditions of _____ CFM entering airtemperature at the evaporator at _____ _F (_C) wet bulband _____ _F (_C) dry bulb, and air entering the unit at_____ _F (_C).

— The system will have a SEER of _____ Btuh/watt orgreater at DOE conditions.

Electrical Requirements— Nominal unit electrical characteristics will be _____ v,

single phase, 60 hz. The unit will be capable ofsatisfactory operation within voltage limits of _____ v to_____ v.

— Nominal unit electrical characteristics will be _____ v,three phase, 60 hz. The unit will be capable ofsatisfactory operation within voltage limits of _____ v to_____ v.

— Unit electrical power will be single point connection.

— Control circuit will be 24v.

Special Features— Refer to section of this literature identifying accessories

and descriptions for specific features and availableenhancements.

Copyright 2007 Carrier Corp. S 7310 W. Morris St. S Indianapolis, IN 46231

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

Catalog No.38YCC---E2PD

Replaces:38YCC---E1PD

Printed in U.S.A. Edition Date: 08/07


Recommended