+ All Categories
Home > Documents > Product Guide_Power Generation Applications.pdf

Product Guide_Power Generation Applications.pdf

Date post: 05-Jul-2018
Category:
Upload: giangdo
View: 224 times
Download: 0 times
Share this document with a friend

of 28

Transcript
  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    1/28

    PRODUCTGUIDE

    Electronic edition – Power generation applications

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    2/28

    The interactive simulator provides a

    taste of the new InteliVision 8, with

    demo and preview options illustrating

    screen information and function.

     s i m u l a t o r

     O N L I N E

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    3/28

    InteliVision 8 is a new generation colour display unit for

    InteliGenNT, InteliSysNT, InteliMainsNT and InteliDrive

    controllers. It is designed as a simple, easy to use

    Plug and Play solution, which also features our

    unique TRENDS monitoring as a standard feature.

    It is the first colour display

    in the Power Generation field.More info on page 54.

    www.comap.cz/intelivision8

    http://-/?-http://-/?-

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    4/28

    The InteliDrive Mobile is a highly flexible sophisticated mobile electronic

    controller, which features outstanding control, monitoring and protection for

    diesel and gas engines as well as driven technology.

    The new controller offers range of specific functions suitable for mobileapplications as hydraulic system control, communication with sensors and

    operational devices control.

    Most commonly, these tailored applications meet the specific control

    requirements of mobile hydraulics, engine driven compressors and pumps.

    InteliDrive® Mobile

    SWITCHED ONTO INNO

    InteliCompactNT

    InteliCompactNT models are new integrated

    controllers for gen-sets operating in both

    standby and parallel modes. Functionality,

    optimized for ease of use, installation and

    configuration, includes built-in synchronizer

    and digital isochronous load sharer.

    … more on page 14 

    more on page 40

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    5/28

    ATION

    The new InteliATSNT controllers are

    designed to monitor the incoming AC

    mains supply (1 or 3 phases) for under

    voltage, over voltage, under frequency,

    over frequency and voltage unbalance.

    … more on page 8 

    InteliATSNT

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    6/28

    WELCOME TO OUR

    PRODUCT GUIDE

    Following the positive feedback

    from our first Product Guide we

    have updated the second issue

    with more information on an ever-

    growing range of control products.

    In the meantime, our design and

    development teams have worked

    very hard to create exciting new

    control solutions to meet customers’

    application needs – all of which aredetailed in the new guide.

    We hope you find it just as useful and

    practical as before. Inside you will

    find technical information, product

    features and functions, alongside

    customer feedback on how the

    products have performed in the

    field. Hearing what you think is very

    important to us, so if you would like

    to share you experience of using

    our products please let us know byemailing your story to [email protected]

    Overall, it offers a comprehensive

    guide to our entire range of products

    and accessories. I hope you find it

    both helpful and invaluable.

     

    Regards

    Libor Mertl – Managing Director

    Power Generation Controllers 7

      ATS controllers  8

      Gen-set controllers  10

      Generator controllers  28

    Drive Power Controllers 33

      Engine controllers  34

      Off-road machinery controllers  40 

    Associated Control Products 43

      Accessories  44

      PC tools  58

      Mains protections  62 

    Electronic potentiometers  64

    Applications 65

      Power generation applications  66

      Drive power applications  80

    About ComAp 91

    CONTENT

    http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-http://-/?-

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    7/28

    This section demonstrates the flexibility and capability of ComAp power

    generation control solutions by illustrating a wide range of applicationsincluding single gen-sets, multiple sets operating in parallel and complex

    CHP (cogeneration) applications. Each example shows how ComAp control

    products integrate seamlessly to deliver a complete and effective control and

    monitoring package for both typical and complex power applications.

    Power generation applications 66

    ComAp drive power control products are suitable for a wide range of diesel

    engine powered plant and equipment. The following applications are just a

    small selection to demonstrate the versatility of ComAp drive power products

    and accessories for use in this demanding market.

    Drive power applications 80

    Applications

         A     P     P     L     I     C

         A     T     I      O     N      S

    65

    http://-/?-http://-/?-

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    8/28

    A P P L I C A T I O N S / A U T O M A T I C T R A N S F E R S W I T C H

     M A I N S

     I A - N T

     I L - N T  M R S  1 0

     S t a r t / S t o p

     R e a d y  t o  l o a d

     T r a n s f e r  d e m a

     n d

     E N G I N E  R

     O O M

     MA R K E T

     O F F I C E

    SUPERMARKET

    Open / delayed transition – auto/manual transfer

     z Stand-by gen-set. InteliATSNT continuously monitors mains supply for under voltage,

    over voltage, under frequency, over frequency and voltage unbalance. In the case of

    mains failure it sends a remote start command to the standby gen-set.

     z InteliATSNT waits for “Ready To Load” signal or standby gen-set voltage – configurable

    - and switches load to the standby generator.

     z After the mains returns the InteliATSNT switches load back to mains and sends remote

    stop command to the standby gen-set.

     z Different delay intervals can be set for individual changeover phases.

     z The changeover can take place also on explicit demand, not only after mains failure.

     z ATS function works with backup battery or in reduced mode without backup battery.

     z 1× InteliATSNT STD

     z 1× arbitrary gen-set controller (e.g. InteliLiteNT MRS 10) or key start box

    Description:

    Scope of supply:

    66

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    9/28

    A P P L I C A T I O N S / S I N G L E G E N S E T

    Prime mover system – remote monitoring via GSM

     z Manual and remote start of gen-set with electronic engine.

    InteliLiteNT MRS 16 starts, controls and monitors the gen-set and

    controls the circuit breaker to supply the load.

     z Service provider can monitor and control gen-set operation

    remotely via GSM modem.

     z Controller sends active SMS or Emails upon alarm event.

     z Generator is protected by built in over/under voltage and

    frequency protections and IDMT overcurrent protection.

     z Controller communicates with engine management unit by CAN

    J1939 bus. Engine values and alarms are visible on graphical

    LCD screen in plain language – no need to learn cryptic flashing

    or numeric error codes.

     z 1× InteliLiteNT MRS 16

     z 1× IL-NT RS232

     z 1× GSM modem (not delivered by ComAp)

    Description:

    Scope of supply:

         A     P     P     L     I     C

         A     T     I      O     N      S

    67

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    10/28

    A P P L I C A T I O N S / S I N G L E G E N S E T

     I L - N T  A M F 

     2 5

     G S M  M O D E

     M 

     M A I N S 

    TV 

    TR ANSMITT

    ER J1939

     

     S E R V I C E  P

     R O V I D E R

     G S M  M O D E

     M # I L - N  T :A

     L = (  ! F l s 

     O i l  P r e s s u r e, !  W

     r n 

     F u e l L e v e l  )

    Standby system – remote monitoring via GSM

     z Stand-by gen-set with electronic engine. InteliLiteNT 

    AMF 25 continuously monitors a mains supply and

    automatically starts an engine and switches load to a

    standby generator set in case of mains failure.

     z Service provider can monitor gen-set operation

    remotely via GSM modem.

     z Generator is protected by built in over/under voltage

    and frequency protections and IDMT overcurrentprotection.

     z Controller communicates with engine management unit

    by CAN J1939 bus. Engine values and alarms are visible

    on graphical LCD screen in plain language – no need to

    learn cryptic flashing or numeric error codes.

     z 1× InteliLiteNT AMF 25

     z 1× IL-NT RS232

     z 1× GSM modem (not delivered by ComAp)

    Scope of supply:

    Description:

    68

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    11/28

     I G L - R A 1 5 

     I C - N T  S P t M

     S E R V I C E 

     P R O V I D E R 

     F I R E W A L L 

     I N T E R N E T 

    ENGINE ROO

     M A I N S 

    DISTRIBUTI

    ON POINT 

    SURGERY 

     I B - L i t e

    A P P L I C A T I O N S / P A R A L L E L I N G G E N S E T S

    Standby system with soft return– remote monitoring and control via Internet

     z Stand-by emergency gen-set accomplishes power supply to essential load during power drop. z Controller automatically starts the gen-set in case of mains failure and switches load to generator.

    When mains returns, it synchronizes the generator back, softly unloads it and stops the engine.

     z Generator automatically synchronizes to mains in Test mode. Test mode can be used to check the

    gen-set condition and to provide uninterrupted power supply in case of expected mains failure.

     z Status of the gen-set is displayed in the distribution point.

     z InteliMonitor is used for remote monitoring and control.

     z History file with performance log stored in InteliCompactNT SPtM allows easy backtracking and

    problem solving.

     z Seamless communication with engine’s electronic injection control unit, all important values and

    alarms are visible on screen of InteliCompactNT and stored to the history file in plain language.

     z 1× InteliCompactNT SPtM

     z 1× IG-AVRi

     z 1× IG-AVRi-TRANS/LV

     z 1× IB-Lite

    Scope of supply:

    Description:

         A     P     P     L     I     C

         A     T     I      O     N      S

    69

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    12/28

    A P P L I C A T I O N S / P A R A L L E L I N G G E N S E T S

     R E M O T E

      C O N T R O L

      R O O M

     I G - I B 

     F I R E W A L L 

     I N T E R N E T

     M C - N T

     M A I N S 

     C A N 2 

     L O A D 

     I C - N T  M I N T

     I C - N T  M I N T

     I C - N T  M I N T

     L O C A L

      C O N T R O L

      R O O M

    Multiple gensets in parallel to grid – remote monitoring and control via Internet

     z Fully automatic system reduces electric energy bill by keeping the mains power below high tariff level during peak hours.

    z At the same time it accomplishes emergency standby power in case of mains failure.

     z Remote control and monitoring uses available factory LAN for connection between a Power house and a Control room. z InteliMonitor is used for remote monitoring and control.

     z Wide range of engine and generator protections, including vector-shift protection.

     z Automatic forward and reverse synchronization with soft load ramp-up and ramp-down during changeover.

     z Active and reactive load import/export control and load-sharing.

     z Automatic optimization of number of running sets according to load.

     z Peak loping controlled by built in Scheduler, engines automatically run during peak period.

     z History file with performance log stored in InteliCompactNT MINT allows easy backtracking and problem solving.

     z Seamless communication with engine’s electronic injection control unit, all important values and alarms are visible on

    screen of InteliCompactNT and stored to the history file in plain language.

     z 3× InteliCompactNT MINT

    z 3× IG-AVRi

     z 3× IG-AVRi-TRANS/LV

     z 1× MainsCompactNT

     z 1× IG-IB

     z 1× IG-IB3 dongle

    Description:

    Scope of supply:

    70

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    13/28

    A P P L I C A T I O N S / P A R A L L E L I N G G E N S E T S

    Rental sets

     I G - N T 

     I M - N T 

     I G - N T 

     I G - N T 

     L O A D 

    z Containerized rental gen-sets can be used for maintenance of power lines without interruption of power delivery

    to end consumer.

     z Gen-sets are connected one-by-one to mains at the consumer’s end and manually loaded. Power line is then

    manually disconnected and consumer is powered from generators running in parallel.

     z The group of gen-sets is reverse synchronized to mains after finalization of maintenance on power line.

    InteliMainsNT keeps generators and mains in synchronism enabling manual reconnection to power line.

     z InteliMainsNT is built in a small shock proof suitcase.

     z Interconnection of containers is done by color coded not-interchangeable connectors.

     z Each gen-set can be used in Stand-by, Single parallel to mains and Multiple parallel modes according to the

    position of Mode selector switch.

     z Frequency selector enables switching between 50Hz / 230V and 60Hz / 277V mains.

     z 3× InteliGenNT

     z 3× IGS-NT-LSM+PMS dongle

     z 3× IG-AVRi

     z 3× IG-AVRi-TRANS/LV

     z 1× InteliMainsNT

    Description:

    Scope of supply:

         A     P     P     L     I     C

         A     T     I      O     N      S

    71

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    14/28

    A P P L I C A T I O N S / P A R A L L E L I N G G E N S E T S

     I  M -  N  T

     I G -  N  T

     I  M -  N  T

     J 1 9 3 9

     I G -  N  T

     J 1 9 3 9

     J 1 9 3 9   B  T  B

    C       A       N        2       

     I  M -  N  T

      P  L C

     I G -  N  T

     I G -  N  T

     E N G I N E  R

     O O M  1

     P R O D U C T I O

     N  HA L L  1

      M A I  N S

    Complex installation – multiple grids

     z Essential load is fed by two mains feeders during normal

    operation to achieve maximum reliability of the power delivery.

    Bus-tie breaker (BTB) is closed.

     z Complex switching algorithm running in external PLC defines

    which breakers are opened and which are closed independent

    on availability of two mains and gen-sets.

     z Reverse synchronizing on both feeders and on bus-tie breakeris accomplished by 5 InteliMainsNT modules controlled by

    external PLC.

     z Active and reactive load-sharing can operate in two modes:

    – Sharing the load between all running gen-sets – if BTB is

    closed

    – Sharing the load in two independent groups – if BTB is

    opened

     z Automatic power dependant start/stop can operate in two

    modes as well:

    – Running on all gen-sets – if BTB is closed

    – Running in two independent groups – if BTB is opened

     z All controllers are interconnected by one CAN bus all thetime, disregarded if BTB is closed or open, no need for relays

    reconnecting the CAN bus.

     z Complete system is remotely controlled and supervised from

    Control room connected via company LAN and IG-IB to all

    controllers.

    Description:

    72

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    15/28

     I  N  T  E  R  N  E  T

     I  M -  N  T

     I G -  N  T

     I  M -  N  T

     J 1 9 3 9

     I G -  N  T

     J 1 9 3 9

     J 1 9 3 9

    C       A       N        

    2       

    L      A       N         /         W        

    A       N        

     I G -  N  T

     I G -  N  T

     I G - I  B

    G I N E  R O O

     M  2

     P R O D U C T I O

     N  HA L L  2

     C O N T R O L  R

     O O M

      M A I  N S

     GA T E

    FACTOR Y

     Ltd.F

     z 6× InteliGenNT

     z 6× IGS-NT-LSM+PMS dongle

     z 6× IG-AVRi

     z 6× IG-AVRi-TRANS/LV

     z 5× InteliMainsNT

     z 1× IG-IB

     z 1× IG-IB 15 dongle

     z 1× optional PLC

    (not delivered by ComAp)

    Scope of supply:

         A     P     P     L     I     C

         A     T     I      O     N      S

    73

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    16/28

    A P P L I C A T I O N S / P A R A L L E L I N G G E N S E T S

     R E C E P T I O N

     K I T C H E N

     R O O M S

    LIFT

     E N G I N E  R

     O O M

     C O N T R O L  R

     O O M

     I M - N T

     M A I N S

     I S - N T

      J 1 9 3 9

      J 1 9 3 9

    C       A       N         2       

     I S - N T

     I N T E L I V I S I O

     N  8

     I N T E L I V I S I O

     N  8

    Standby system with load shedding – advanced displays

     z The system guarantees emergency standby power in case of mains failure.

     z InteliMainsNT provides AMF function and activates mains to gen-sets changeover in the case of mains failure no break return to mains.

     z Load shedding can take place during the changeover to trip the unessential load when gen-set goes to island.

     z Gen-set starts, the power is ramped-up, load is reconnected. The second gen-set is started if needed (more load requires more gen-

    set power).

    z Automatic forward and reverse synchronisation with soft load ramp-up and ramp-down during changeover is available.

     z Wide range of engine and generator protections, including vector shift protection are standard features.

     z Automatic optimization of number of running sets according to load can be selected.

     z Automatic equalization of running hours of particular engines is available.

     z The second gen-set can be used as a backup set.

     z History file with performance log stored in InteliSysNT allows easy backtracking and problem solving.

     z 2× InteliSysNT

     z 2× IGS-NT-LSM+PMS dongle

     z 2× InteliVision 8

     z 1× InteliMainsNT z 2× IG-AVRi

     z 2× IG-AVRi-TRANS/LV

    Description:

    Scope of supply:

    74

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    17/28

    A P P L I C A T I O N S / P A R A L L E L I N G G E N S E T S

    Multiple loads – several mains supplies

     G C B  # 3

     C G C B

     J 1 9 3 9

     G C B  # 1

     M A I N S  # 1

     M A S T E R

     S E L E C T O R

     F E E D B A C K

     M A S T E R

     S E L E C T O R

     M C B  # 1

     M A N  1,  2,  3

     G C B  # 2

     M A I N S  # 2

     M C B  # 2

     M A I N S  # 3

     M C B  # 3

     I S - N T

     M a i n s P r o

     M a i n s P r o

     M a i n s P r o

     M C B

     G C B

     1,  2,  3

     P L C

     P O W E R  C O

     N T R O L

     C E N T E R

     z In case of manipulation, the system switches from one branch to another by turning of the Master Selector Switch (MSS): BO

    MSS turn is used to turn the MSS.

     z The mains voltage measurement, generator current measurement, MCB and GCB feedbacks, MCB and GCB control signals and

    Mains Failure (MF) signals (MainsPro outputs) are switched by the MSS, so that the system continuously “sees” only the selected

    branch.

     z MCB and GCB are operated by pulse signal (GCB open/close, MCB close). The pulse is issued as a request for CB operation and

    terminated at the moment of corresponding feedback receipt.

     z The MainsPro relays monitor mains on all 3 branches. In case of any MF, the gen-set is started.

     z In case of MF on any branch, the proper MainsPro opens MCB, MSS switches to the failed branch and closes GCB.

     z If a MF occurs on a different branch at the same moment, the controller finishes manipulation of GCB, MSS switches to a

    different branch and closes the other GCB.

     z After an existing MF state terminates on any branch, the MSS turns to this branch, InteliSys NT reverse-synchronizes and closes

    MCB and opens GCB. Short-time parallel is allowed on the current branch.

     z The MSS is blocked from moving away from a branch, where:

    – parallel operation is in effect

    – GCB open/close or MCB close signals are active

    – MF signal is in effect and GCB is open

     z In case that all existing MF are solved and all GCB’s are open, the gen-set stops.

     z 1× InteliSysNT

     z 3× MainsPro

    z 1× IG-AVRi

     z 1× IG-AVRi-TRANS/LV

     z 1× PLC (not delivered by ComAp)

     z 1× Motorized rotary switch with 3 × 16 contacts (not delivered by ComAp)

    Description:

    Scope of supply:

         A     P     P     L     I     C

         A     T     I      O     N      S

    75

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    18/28

     R E C E P T I O

     N

     O F F I C E

     E N G I N E  R O

     O M

     P O O L

    Heat exchanger/boiler   Exhaust

    Heating water 

    Fuel line

    Engine

    Generator    Electrical supply

    Electrical

    panel

       P  r  e  s  s  u  r  e

       T  e  m  p  e  r  a   t  u  r

      e

       T  e

      m  p  e  r  a   t  u  r  e

    Temperature

    Pressure

       T  e  m  p  e  r  a   t  u  r  e

       P  r  e  s  s  u  r  e

       T  e  m  p  e  r  a   t  u  r  e

       P  r  e  s  s  u  r  e

    Pressure

    Temperature

    Temperature

       T  e  m  p  e  r  a   t  u  r  e

       T  e  m  p  e  r  a   t  u  r  e

       T  e  m  p  e  r  a   t  u  r  e

       P  u  m  p

       P  u  m  p

       V  e  n   t   i   l  a   t   i  o  n

       H  e  a   t   (   J  o  u   l  e   )

    2009 

    2009 

    A P P L I C A T I O N S / P A R A L L E L I N G G E N S E T S

    Combined heat and power (CHP) – cogeneration

    76

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    19/28

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    20/28

     S H A F T  G

     P R O P U L

     S I O N

     E N G I N E

     A U X  G E N

      1

     A U X  G E N

      2

     B O W  T H R

     U S T E R

     A U X  G E N E R

     A T O R  1

     A U X  G E N E R

     A T O R  2

     E N G I N E

     C O N T R O L L

     E R

     E N G I N E

     C O N T R O L L

     E R

     A U X  G E N E R

     A T O R

     C O N T R O L L

     E R

     A U X  G E N E R

     A T O R

     C O N T R O L L

     E R

     S H A F T  G E N

     E R A T O R

     C O N T R O L L

     E R

     S H A F T  G E N

     E R A T O R

     P R O T E C T I O

     N

     E S S E N T I A L

     C O N S U M E R

     S

     H E A V Y

     C O N S U M E R

     B L O C K I N G

     N O N E S S E N

     T I A L

     C O N S U M E R

     S

     A U X  G E N E R

     A T O R

     P R O T E C T I O

     N

     A U X  G E N E R

     A T O R

     P R O T E C T I O

     N

     G E N E R A T O

     R 1

     G E

    A P P L I C A T I O N S / P A R A L L E L I N G G E N E R A T O R S

    Ship power management system

    78

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    21/28

     

    HA F T

    A T O R

    2

     S H A F T  G E N

     E R A T O R

     z Two auxiliary generators and one shaft generator deliver electricity for systems of the ship.

    Generators are controlled by GeCon controllers in MINT (Master) configurations.

    z PMS can work in three basic operational modes:

    – MANUAL – complete manual control

    – SEMI-AUTO – synchronizing and load-sharing is automatic; genset start/stop and loadtransfer between aux and shaft generators in manual

    – AUTO – complete automatic control

    z PMS continuously evaluates load reserve on the bus and blocks start of the bow thruster if

    the load reserve is insufficient.

     z PMS automatically trips the non-essential consumers, if the power system is overloaded.

    z PMS can control up to 10 independent circuits of non-essential consumers.

     z Freely programmable built-in PLC functions are used to accomplish load transfer between

    shaft and auxiliary generators.

     z 6× InteliGenNT GeCon

     z 2× InteliDrive DCU Marine

     z 3× InteliVision 8

     z 6× IG-AVRi

     z 6× IG-AVRi-TRANS/LV

    Description:

    Scope of supply:

         A     P     P     L     I     C

         A     T     I      O     N      S

    79

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    22/28

    USA

    Netherlands Slovakia

    Canada

    “We admire ComAp products because of their innovative features.

    These include forward looking technological development

    of monitoring; the ability to solve non-standard customers’

    requirements and the huge spectrum of opportunities for running

    of power supplies.” 

    Peter ŠiškaChief of Application and costing

    estimation department 

    www.elteco.sk

    “ComAp’s compressor and engine control panel solution optimizes

    natural gas production on Boss’s booster units by providing

    accurate process control using digital pressure transducers.

    Our customers are very happy with its event history capabilities

    as well as its compressor and engine protective features. We also

    value the fact that the ComAp ID-DCU panel is fully compatible with

    future electronic emission certified engines

    and control capabilities. BOSS Industries has

    standardized on the ComAp panel for our gas

    well booster compressor units.“ 

    Ed KetchamVP Sales 

    www.bossair.com

    “All our generator sets and propulsion engines are equipped with

    a ComAp engine controller, ID-DCU Marine. They are approved by

    all major Ship Classification Companies. The units fulfill our high

    quality standards, have many applications and are widely used.

    Remote monitoring is one of them, which Sandfirden Technics is

    using in some cases.“ 

    Harry JasperService Manager 

    www.sandfirden.nl

    ”When I first saw InteliVision, I immediately recognized its

    potential for our power generation systems. The large easy to read

    color display and customer-friendly interactivity is precisely what

    our customers have been looking for. We have already installed

    systems with InteliVision and received very positive feedback from

    our customers on the units performance.“ 

    Santokh SahotaEngineering Manager 

    www.simson-maxwell.com

    Boss Industries

    Sandfirden Technics ELTECO

    Simson-Maxwell

    Satisfied CustomersWorldwide

    90

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    23/28

    About ComAp

    91

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    24/28

    Excellent and reliable product solutions

    ComAp specializes in creating electronic control andmanagement solutions for use in the power generation

    industries and drive power markets. Our portfolio of

    products, software and accessories is designed to support

    emergency power, standby power generation and engine

    driven applications all over the world. We also work closely

    with our customers to develop unique customized and turn

    key solutions for ordinary and extraordinary applications

    delivering high standards of excellence on every project.

    ComAp products

    represent some of the

    most reliable solutions

    on the market today.

    Every component and

    product undergoes the

    most rigorous standards

    during manufacture,

    with every stage being

    undertaken in accordance

    with international ISO

    9001 certification. Our

    products are backed

    with the approvals from

    92

    ComAp

    ComAp is a dynamic international company

    with a solid reputation for delivering

    innovative electronic solutions to the power

    generation, industrial engine and equipment

    markets. By providing customers withstate-of-the-art products, ComAp has built

    a name for delivering excellent reliability

    and good value.

    major Marine Certification Societies. Accreditation at the

    highest-level breeds confidence, and every ComAp product

    is supplied with an appropriate warranty and after-sales

    support for complete peace of mind.

    People make the difference

    ComAp‘s key strengths are flexibility, experience,

    knowledge and enthusiasm. This blend of values defines

    our personality and gives you the assurance of a truly

    honest and positive relationship. By supporting our

    people, investing in their development and encouraging

    creativity, our teams work hard to find new opportunities,

    technologies and solutions that enable us to successfully

    help our customers solve their problems effectively.

    At ComAp, we believe passionately in the importance

    of continuously developing new technology along with

    forward thinking software and hardware to maintain the

    enviable position as worldwide leader in communicationand control for power generation and drive power

    applications.

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    25/28

    At the heart of this process

    is a strong desire to

    exceed our customers’expectations by finding

    outstanding solutions for

    them and drawing upon the

    company’s most valuable

    asset – people. Over 80 %

    of ComAp employees are

    graduates with specialized

    electronic and programming

    knowledge appropriate to

    the innovative development

    of market-orientated

    engine management

    systems. This unique

    know-how is matched

    by ComAp’s significant

    investment at every stage of the research and development

    process, resulting in the creation of leading edge modern

    development facilities. ComAp consistently set high

    standards, reflected by our achievement in the ‘Best

    Employers Study in the Czech Republic‘ (conducted by

    Hewitt Associates), where we were awarded first place in

    2008 following our consecutive third places in both 2006

    and 2007.

    ComAp Systems

    ComAp’s expertise extends beyond innovative controllers

    to include a range of subsidiary businesses specializing

    in related services including bi-fuel conversions, power

    energy systems solutions and gas engine management.

    These subsidiaries are located in key strategic regions

    around the world ensuring our customers benefit f rom

    local capability coupled with global reach. Most of them are

    named ComAp Systems and more information is availableon each business at www.comapsystems.com.

    93

    Key Milestones

    1991

    Establishment of ComAp.

    1993

    Successful commissioning of four

    Gen-set Control Systems made by ComAp on

    Mediterranean islands.

    1994MX controller, the second generation of

    ComAp’s gen-set control systems, was

    launched.

    1996PX, the revolutionary gen-set controller

    with configurable input and outputs, was

    developed.

    1999The strategic co-operation with HuegliTech

    Company significantly increased our

    distribution network.

    2000

    InteliGen, the first member of the Inteli family

    and flagship of our gen-set control systems,

    was released.

    2001ComAp Ltd. – 100 % UK based ComAp

    subsidiary was established close to Bristol.

    2002InteliSys, our top end product dedicated to

    CHP and large engine control applications, was

    released. New mid-range product InteliLite was

    launched for AMF and MRS applications.

    2004InteliDrive controller for non gen-set, engine

    driven applications was released.

    2006ComAp LLC – ComAp subsidiary to promote

    products in the USA and Canada.

    2007InteliVision – the first color display unit in

    power generation field.

    2008InteliCompact – controller for simple

    paralleling gensets.

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    26/2894

    Professional partnerships

    ComAp products are directly available in more than 60 countries, spanning almost every continent in the world. Through our

    professional and highly dedicated global distributor network we can satisfy customers’ needs, however challenging.

     

    Each ComAp distributor is carefully selected for their professionalism, product exper tise and recognized quality standards and

    accreditation, and as such can advise customers on any matter relating to ComAp products and their applications.

    For detail information about the distributors, p lease visit www.comap.cz/distributors

    AlgeriaH-T-Fwww.h-t-f.fr

    ArgentinaSERVINTEL INTERNATIONAL S.A.www.servintel.com

    AustraliaGREENBIRD TECHNOLOGYwww.greenbird.com.au

    AustriaHUEGLI TECH AG (LTD)www.huegli-tech.com

    BangladeshCOMAPwww.comap.cz

    Bosnia andHerzegovina

    KOCH D.O.O.www.koch.ba

    BrazilSERVINTEL INTERNATIONAL S.Awww.servintel.com

    BulgariaCOMAPwww.comap.cz

    CanadaCOMAP LLCwww.comapllc.com

    ChileSERVINTEL INTERNATIONAL S.A.www.servintel.com

    ChinaJONES ENGINEERING CO., LTD.www.jones.com.hk

    ColombiaSOLUCIONES PRODUCTIVASwww.powergen.com.co

    Costa RicaPROPACE INGENIERIA, S.Awww.propace.net

    CroatiaKOCH D.O.O.www.koch.ba

    DenmarkPTECHwww.ptech.dk

    East TimorGREENBIRD TECHNOLOGY www.greenbird.com.au

    EcuadorSVF ECUADOR S.A.www.svf-international.com

    EgyptPOWER FOR CONTRACTING & ELECTRO.www.elmotahdagroup.com

    EstoniaTAPIMEC OY www.tapimec.fi

    Faroe IslandsPTECHwww.ptech.dk

    FinlandTAPIMEC OY www.tapimec.fi

    FranceH-T-Fwww.h-t-f.fr

    GermanyHUEGLI TECH AG (LTD)www.huegli-tech.com

    GreeceA. SAPOUNAS S.A.www.sapounas.gr

    GreenlandPTECHwww.ptech.dk

    Hong KongJONES ENGINEERING CO., LTD.www.jones.com.hk

    IndiaMADHURA INTERNATIONALwww.madhura.net

    IndonesiaPT. FS POWER CONTROLwww.fspowercontrol.com

    IraqCOMAPwww.comap.cz

    IrelandINDUSTRIAL POWER UNITS LTD.www.ipu.co.uk

    IsraelGENERKAL INDUSTRIES LTD.www.generkal.co.il

    ItalyBIMOTOR S.R.L.www.bimotor.it

    KazakhstanCOMAP SYSTEMS RUwww.comapsystems.ru

    KuwaitCOMAPwww.comap.cz

    LatviaCOMAPwww.comap.cz

    LebanonJABBOUR DATAKOM S.A.R.L.www.jabbourpower.com

    LithuaniaCOMAPwww.comap.cz

    LuxembourgCONTROLIN BVwww.controlin.nl

    MacedoniaKOCH D.O.O.www.koch.ba

    MalaysiaSUNPOWER ENGINEERING & [email protected]

    MexicoDUPONT ELEKTRIC MEXICO, SA DE CVwww.dwppon.com

    MongoliaCOMAPwww.comap.cz

    NetherlandsCONTROLIN BVwww.controlin.nl

    New ZealandGREENBIRD TECHNOLOGYwww.greenbird.com.au

    NigeriaMIKANO INTERNATIONAL LIMITEDwww.mikano-intl.com

    NorwayINDUSTRIMARIN ASwww.industrimarin.com

    PakistanR.A. ENGINEERING & SERVICESwww.raeng.com

    Papua NewGuinea

    GREENBIRD TECHNOLOGY www.greenbird.com.au

    PeruCOMAPwww.comap.cz

    PhilippinesSTATIC POWER PHILIPPINES, [email protected]

    PolandBTH FASTwww.bthfast.eu

    PortugalGENCONTROL SYSTEMS, S.A.www.gencontrol.es

    RomaniaCOMAPwww.comap.cz

    RussiaCOMAP SYSTEMS RUwww.comapsystems.ru

    Serbia andMontenegro

    KOCH D.O.O.www.koch.ba

    SingaporeCOMAPwww.comap.cz

    South AfricaCOMAPwww.comap.cz

    South KoreaBOO YOUNG CORPORATIONwww.boo-young.com

    South KoreaEMECS ENGINEERINGwww.emecs.co.kr

    SpainGENCONTROL SYSTEMS, S.A.www.gencontrol.es

    Sri LankaCOMAPwww.comap.cz

    SwedenINDUSTRIMARIN SVERIGE ASwww.industrimarin.com

    SwitzerlandHUEGLI TECH AG (LTD)www.huegli-tech.com

    TaiwanARITH COMPANY LTD.www.arith.com.tw

    TunisiaH-T-Fwww.h-t-f.fr

    TurkeyBETEX ENGINEERING IMPORT & EXPORTwww.betex.com.tr

    UnitedKingdom

    INDUSTRIAL POWER UNITS LTD.www.ipu.co.uk

    UnitedStates

    COMAP LLCwww.comapllc.com

    UruguaySERVINTEL INTERNATIONAL S.A.www.servintel.com.ar

    VietnamDP CONSULTING CO., LTD.www.dp-consulting.com.vn

    http://www.comap.cz/distributorshttp://www.comap.cz/distributors

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    27/28

  • 8/16/2019 Product Guide_Power Generation Applications.pdf

    28/28

    ComAp, spol. s r. o.

    Kundratka 2359/17 • 180 00 Praha 8 • Czech Republic

    Phone: + 420 246 012 111 • Fax: + 420 266 316 647

    [email protected] • www.comap.cz

    Manufacturer

    Local Distributor / Partner

    Customer satisfaction is our mission. We continuously develop the best people to succeed in our mission.

    We are looking

    forward to your visit.

    mailto:[email protected]://www.comap.cz/mailto:[email protected]://www.comap.cz/