+ All Categories
Home > Documents > Product Line QUALITY | EFFICIENCY | SAFETYproducts.ryeco.com/Asset/Single Page Line Card.pdfOLL SYnc...

Product Line QUALITY | EFFICIENCY | SAFETYproducts.ryeco.com/Asset/Single Page Line Card.pdfOLL SYnc...

Date post: 07-May-2018
Category:
Upload: vanphuc
View: 217 times
Download: 4 times
Share this document with a friend
2
places marks on a web at a position relative to a defect or process upset encodes values onto a moving web places a mark on a web after a sheet break is restored places continuous or dashed stripes on a web to indicate web orientation or product type places a mark on a roll indicating the end of the roll is approaching to downstream operators and users places marks on a web at precise distance intervals to be used as a registration mark for downstream processes counts sheets as they are stacked and places a mark at a specified number of sheets Marking Technologies detects ply breaks in a multi-ply tissue web detects fold-overs along the edge of a moving web detects an open draw break in any web process using a laser for extended sensing distance detects a sheet break in uni-run or other sheet-on-fabric processes Break Detection Technologies Extended Range Break Detection Sheet-on-Fabric Break Detection Ply Break Detection Fold-Over Detection Edge Crack Detection Technologies SY1 | Edge Crack Detection SY2 | Edge Crack Detection and Marking detects and marks separated and un-separated cracks along the edge of a moving web detects separated and un-separated cracks along the edge of a moving web Product Line detects overlapping splices in a moving paper or film web Stretch and Shrink Monitoring, Length and Position Control, End of Roll Auto-Stopping, Auto-Stop on Defects, Set-Length Control, and Waste Tracking detects the presence of marks placed on a web by a Marking System detects and decodes values of code marks placed on a moving web by a RYECO Code Marking System tracks instantaneous stretch and shrinkage in a flexible web Converting Management Technologies Mark Detection Decoding Distortion Monitoring Splice Detection OLLSYnc
Transcript

QUALITY | EFFICIENCY | SAFETY

places marks on a web at a position relative to a defect or process upset

encodes values onto a moving web

places a mark on a web after a sheet break is restored

places continuous or dashed stripes on a web to indicate web orientation or product type

places a mark on a roll indicating the end of the roll is approaching to downstream operators and users

places marks on a web at precise distance intervals to be used as a registration mark for downstream processes

counts sheets as they are stacked and places a mark at a specified number of sheets

Marking Technologies

detects ply breaks in a multi-ply tissue web

detects fold-overs along the edge of a moving web

detects an open draw break in any web process using a laser for extended sensing distance

detects a sheet break in uni-run or other sheet-on-fabric processes

Break Detection Technologies Extended Range Break Detection

Sheet-on-Fabric Break Detection

Ply Break Detection

Fold-Over Detection

Edge Crack Detection TechnologiesSY1 | Edge Crack Detection SY2 | Edge Crack Detection and Marking

detects and marks separated and un-separated cracks along the edge of a moving web

detects separated and un-separated cracks along the edge of a moving web

Product Line

detects overlapping splices in a moving paper or film web

Stretch and Shrink Monitoring, Length and Position Control, End of Roll Auto-Stopping, Auto-Stop on Defects, Set-Length Control, and Waste Tracking

detects the presence of marks placed on a web by a Marking System

detects and decodes values of code marks placed on a moving web by a RYECO Code Marking System

tracks instantaneous stretch and shrinkage in a flexible web

Converting Management Technologies Mark Detection

Decoding

Distortion Monitoring

Splice Detection

OLLSYnc ™

AUSTRALIA & NEW ZEALANDGary Ramsay Mill Link Services P/L Telephone: +61 412588663 Email: [email protected]

BRAZILMarina de Moura Blades Telephone: +5511 56314756 Email: [email protected]

BELGUM, NETHERLANDS & LUXEMBURGPhillippe Van Bockxelaere Stevin Consult n.v. Telephone: +32 (03)7659204 Email: [email protected]

CHILEHernan Cecereu Technology Trade Consulting Chile S.A. Telephone: +56 (02)29804898 Email: [email protected]

CHILE & ARGENTINAPablo Vidales TRIPROM Telephone: +56 98205228 Email: [email protected]

KOREAYoung-Bae Kim MS Tech Co Ltd Telephone: +82 415531975 Mobile: +82 1052621975 Email: [email protected]

CHINAJimmy QiuWillTech (Shanghai) Equipment Co., LtdTelephone: (+86) 2169902862 Email: [email protected]

FRANCEAlain LeroyBobinov Telephone: +33 344886099 Email:[email protected]

FINLAND, NORWAY, DENMARK & SWEDENMikko Ahonen Vision Systems Oy Telephone: +358 103327100 Email: [email protected] [email protected]

INDIATushar Deshpande Conteq Technologies Telephone: +91 9843077796 Email: [email protected]

SPAINTeri Vidal Eurotech Systems, S.L. Telephone: +34 936340101 Fax: +34 936240677 Email: [email protected]

GERMANY, AUSTRIA & SWITZERLANDJordie DijstraDYETRADETelephone: +49 22516504380Email: [email protected]

MEXICOMario Gonzalez G Engineering SC Telephone: +521 8112553228 Email: [email protected]

INDONESIASjamsuwar & Andy PT Chempart Global Solution Telephone: +62 811997399 +62 5460935 Email: [email protected] [email protected]

ITALYMarzio Pesenti Pesenti sas Telephone: +39 035639940 Email: [email protected]

JAPANYasuhiro Takeyama MATSUBO Corporation Telephone: +81 354721747 Mobile: +81 908378324 Email: [email protected]

810 Pickens Industrial DriveMarietta, GA 30062

tel // 770.423.0934fax // 770.424.2554

www.ryeco.com

UNITED KINGDOM & IRELANDPeter Fish Prisma Services Ltd Telephone: +44 1246852052 Email: [email protected]

NORTH AMERICATim Rye & Jane Adams RYECO, Inc. Telephone: +1 7704230934 Email: [email protected] [email protected]

MIDDLE EASTHany Nabil Hafez & Ahmed Mohamed Automation Technology ‘Autotec’ Telephone: +20 1005666770 Email:@[email protected] [email protected]

POLANDKrzysztof MelaMela - MTS PolskaTelephone: +48 757132456Email: [email protected]@mts-polska.com.pl

TAILANDWeston Myer Ltd.Telephone: +66 29199787

QUALITY | EFFICIENCY | SAFETY

Partners & Representatives


Recommended