©2003 Citadel Architectural Products, Inc. An ISO 9001:2000 Registered Company. GlazeGuard ® is a registered trademark of Citadel Architectural Products, Inc. Printed In The U.S.A. Form # 7.06-10.MA.A Rev. (06/03) Supersedes (12/98) PRODUCT MANUAL Citadel Architectural Products, Inc. • An ISO 9001:2000 Registered Company • 3131-A North Franklin Road Indianapolis, Indiana 46226 • phone (800) 446-8828 • fax (317) 894-6333 • www.citadelap.com • [email protected] Rev. (11/06)
Transcript
Page 1: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

©2

00

3 C

itad

el A

rch

itect

ura

l Pro

du

cts,

In

c.

An

IS

O 9

00

1:2

00

0 R

eg

iste

red

Co

mp

an

y.G

laze

Gu

ard

® is

a r

eg

iste

red

tra

de

ma

rk o

f C

itad

el A

rch

itect

ura

l Pro

du

cts,

In

c.P

rin

ted

In

Th

e U

.S.A

. F

orm

# 7

.06

-10

.MA

.A

Re

v. (

06

/03

) S

up

ers

ed

es

(12

/98

)

PRODUCT MANUAL

Citadel Architectural Products, Inc. • An ISO 9001:2000 Registered Company • 3131-A North Franklin RoadIndianapolis, Indiana 46226 • phone (800) 446-8828 • fax (317) 894-6333 • www.citadelap.com • [email protected]

Rev. (11/06)

Page 2: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Table Of ContentsPRODUCT DATA SHEET

INSTALLATION GUIDELINES

GUIDE SPECIFICATION

STANDARD WARRANTY

Panel & System Description

Pre-Installation Guidelines

General Work

Work SequenceMaintenance Of The Panel Finish

Basic Uses & ApplicationsComposition & MaterialsPanel Weight & ThicknessMaterial TolerancesSizes AvailableGeneral Limitations

Material Receiving & InventoryTransporting & HandlingStoring The Material Units

Limitations Of The Panel SystemFabrication Of The PanelsThe Protective Film

Citadel Architectural Products, Inc.3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400

(800) 446-8828fax: (317) 894-6333

(800) [email protected]

CUSTOMER SERVICE &TECHNICAL ASSISTANCE Call (800) 446-8828 or visit

www.citadelap.com for downloads!...

SAMPLES & LITERATURE:Product or color samples, as well as additional literature may beobtained by contacting our sample department.

BINDER ON CD:Our complete binder is available on CD in an easy-to-use .pdfformat. Also included are Guide Specifications in MicroSoft® Word®

(.doc) and NotePad (.txt) formats as well as Typical Details inAutoCAD® drawing format (.dwg).

Page 3: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc. GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.com PRODUCT DATA SHEET

©2

00

3 C

itad

el A

rch

itect

ura

l Pro

du

cts,

In

c.

An

IS

O 9

00

1:2

00

0 R

eg

iste

red

Co

mp

an

y.G

laze

Gu

ard

® is

a r

eg

iste

red

tra

de

ma

rk o

f C

itad

el A

rch

itect

ura

l Pro

du

cts,

In

c.P

rin

ted

In

Th

e U

.S.A

. F

orm

# 7

.06

.PD

.A

Re

v. (

06

/03

) S

up

ers

ed

es

(12

/98

)

Product Data Sheet

Metric (mm)

.254mm

.609mm

.390mm4.76mm

Component

Prefinished Textured Aluminum Skins(or) Prefinished Smooth Aluminum Skins(or) Porcelain Enamel Steel SkinsTempered Hardboard Core

Standard (in)

.010”

.024” (min)28ga3/16”

¹ Technical Properties (see back) are based upon the Typical Composition. Selecting optional componentsmay alter these properties.

TABLE 1. COMPOSITION & MATERIALS1:

PANEL & SYSTEMDESCRIPTION

FEATURES & BENEFITS:As a line of glazing infill solutions, GlazeGuard® offers a number ofbenefits to the building owner, architect, and installer including:

• Versatile With a complete line of options, GlazeGuard® panels offer solutions for water and fire resistant compositions in addition to the standard panel.

• Durable Whether installed in new or retrofit applications, the tempered hard- board core provides superior impact and dent resistance.

• Low Maintenance Little or no maintenance is required and most grease, dirt, oil and other foreign material can be easily cleaned from the surface using mild detergents.

• Variety Of Finish Options GlazeGuard® panels are available in a wide range of colors and finishes. From solid tones in textured aluminum and porcelain enamel steel to metallic and anodized finishes in smooth skins, these panels provide the designer with a broad palette to work from.

• Economical Alternative With several different compositions and finish options, GlazeGuard®

can provide an economical alternative to other glazing solutions while still providing aesthetic interest and value.

PRODUCT NAME:GlazeGuard® 250Opaque Glazing Panels

MANUFACTURER:Citadel Architectural Products, Inc.3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400

(800) 446-8828fax: (317) 894-6333

(800) 247-2635web: www.citadelap.comemail: [email protected]

OVERVIEW:GlazeGuard® 250 is a compositepanel made by laminating eithertextured or smooth aluminum skins(or porcelain enamel steel) to atempered hardboard substrate.

Panels are furnished with astrippable film (or interleafedmicrofoam) on the painted surfacesto protect the finish during shipmentand installation.

GlazeGuard® 250 is installed inaluminum glazing/storefront chan-nels (typically on setting blocks) andsealed using gaskets. No mechani-cal fasteners or adhesives are usedin the installation of the panel.

BASIC USES & APPLICATIONS:As an alternative or complementto glass, GlazeGuard® panelsprovide an excellent choice for useas glazing infill, spandrel panels,modesty screens, and railing inserts.

These panels are typically used onvarious types of buildings includingschools and universities, retailcomplexes, storefront conditionsetc... However, with an impactresistant core, GlazeGuard® 250panels are ideal for any otherapplication where durability andsafety are concerns.

GENERAL LIMITATIONS:GlazeGuard® panels are designed tobe installed in glazing channels orother similar type channels where all

Page 4: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc.GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.comPRODUCT DATA SHEET

four edges are sealed. The panelsare not eligible for use as a wallcladding or system. No moldings areavailable with GlazeGuard® panels.

SYSTEM FINISHES:GlazeGuard® 250 panels areavailable with either smooth ortextured prefinished aluminum orporcelain enamel steel skins.

Standard colors in textured skins areoffered with a coil coated polyester.Premium colors are also availablewith an acrylic urethane coating.

Smooth standard and metallic colorsare furnished with a durable Kynar500® coating. Anodized finishes arealso standard.

Whether smooth or textured, bothfinishes can be ordered in customcolors to match customers’ standard.

Porcelain enamel steel is available inboth standard and premium colors.

6.83 kg/m²6mm

Panel Weight¹Nominal Thickness

TABLE 2. PANEL WEIGHT & THICKNESS:

1.40 lbs/ft²1/4”

(1219mm x 2438mm)(1219mm x 3048mm)(1219mm x 3658mm)(1524mm x 2438mm)(1524mm x 3048mm)(1524mm x 3658mm)

48” x 96”48” x 120”48” x 144”60” x 96”60” x 120”60” x 144”

Cut-to-size panels are also available invirtually any size up to 60” x 144”.

SIZES AVAILABLE:Thickness:Length Dim:Width Dim:Squareness:

GlazeGuard® is supplied with clean,machine trimmed edges.

MATERIAL TOLERANCES:±1/32” (±0.79mm)+0, -1/8” (+0, -3.18mm)+0, -1/8” (+0, -3.18mm)1/64” (0.4mm) perlineal foot

LOAD DEFLECTION¹:

Metric (mm)Component Standard (in)

¹ Panel tested while supported on four sides.

5.0

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

0.5

0

De

fle

cti

on

(in

)

0

5.2

10

.4

15

.6

20

.8 26

31

.2

36

.4

41

.6

46

.8 52

57

.2

Load (psf)

4’x8’

4’x4’

PANEL FINISH SYSTEMS:

STANDARD WARRANTY:

Panel Warranty:Polyester/AcrylicFinish:

Kynar 500® Finish:

Anodized Finish:Porcelain Steel:

5 Years5 YearsNo change greaterthan 6 for chalk,8 E units for fade20 YearsNo change greaterthan 8 for chalk,5 E units for fade20 Years (prorated)20 YearsNo chalkNo change greaterthan 5 E unitsfor fade

Standard Textured:

Custom Textured:

Standard Smooth:

Custom Smooth:

Coil CoatedPolyesterSpray AppliedAcrylic UrethaneCoil CoatedKynar 500®

(or) PorcelainEnamel SteelSpray AppliedKynar 500®

R-ValueFlame SpreadStiffness (EI)¹Allowable BendingMoment¹Tensile Yield¹Ultimate Tensile¹

TABLE 3. PANEL PERFORMANCE:

0.5Class A2.36E+4

2.96E+1

6.24E+3

8.16E+3

---ASTM E84ASTM E72ASTM E72

ASTM E72ASTM E72

°F ft²/BTU---lb-in²/ft widthlb-ft/ft width

lb/ft widthlb/ft width

ValueProperty Test Unit

¹ Weight and testing based upon panels using an .010” textured face skin and an .010” textured back skin.

Page 5: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc. GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.com PRODUCT DATA SHEET

©2

00

5 C

ita

de

l A

rch

ite

ctu

ral

Pro

du

cts,

In

c.

An

IS

O 9

00

1:2

00

0 R

eg

iste

red

Co

mp

an

y.G

laze

Gu

ard

® is

a r

eg

iste

red

tra

de

ma

rk o

f C

itad

el A

rch

itect

ura

l Pro

du

cts,

In

c.P

rin

ted

In

Th

e U

.S.A

. F

orm

# 7

.07

.PD

.B

Re

v. (

03

/05

) S

up

ers

ed

es

(06

/03

)

Product Data Sheet

PANEL & SYSTEMDESCRIPTION

PRODUCT NAME:GlazeGuard® 250 WRWater Resistant OpaqueGlazing Panels

MANUFACTURER:Citadel Architectural Products, Inc.3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400

(800) 446-8828fax: (317) 894-6333

(800) 247-2635web: www.citadelap.comemail: [email protected]

OVERVIEW:GlazeGuard® 250 WR is a compositepanel made by laminating eithertextured or smooth aluminum skinsto a high density polypropylene core.

Panels are furnished with astrippable film (or interleafedmicrofoam) on the painted surfacesto protect the finish during shipmentand installation.

GlazeGuard® 250 WR is installed inaluminum glazing/storefront chan-nels (typically on setting blocks) andsealed using gaskets. No mechani-cal fasteners or adhesives are usedin the installation of the panel.

BASIC USES & APPLICATIONS:As an alternative or complementto glass, GlazeGuard® panelsprovide an excellent choice for useas glazing infill, spandrel panels,modesty screens, and railing inserts.

These panels are typically used onvarious types of buildings includingschools and universities, retailcomplexes, storefront conditionsetc... However, with a water resistantcomposition and a variety of finishoptions, GlazeGuard® 250 WRpanels are ideal for other applica-tions such as areas where moistureintrusion is a key concern.

GENERAL LIMITATIONS:GlazeGuard® panels are designed tobe installed in glazing channels

Metric (mm)

.254mm

.609mm6.00mm

Component

Prefinished Textured Aluminum Skins(or) Prefinished Smooth Aluminum SkinsHigh Density Polypropylene Core

Standard (in)

.010”

.024” (min)1/4”

¹ Technical Properties (see back) are based upon the Typical Composition. Selecting optional componentsmay alter these properties.

TABLE 1. COMPOSITION & MATERIALS1:

FEATURES & BENEFITS:As a line of glazing infill solutions, GlazeGuard® offers a number ofbenefits to the building owner, architect, and installer including:

• Versatile With a complete line of options, GlazeGuard® panels offer solutions for water and fire resistant compositions in addition to the standard panel.

• Water Resistant An innovative polypropylene core makes GlazeGuard® 250 WR panels virtually unaffected by any incidental moisture intrusion which may occur in a typical glazing system.

• Low Maintenance Little or no maintenance is required and most grease, dirt, oil, and other foreign material can be easily cleaned from the surface.

• Variety Of Finish Options GlazeGuard® panels are available in a wide range of colors and finishes. From solid tones in textured aluminum to metallic and anodized finishes in smooth skins, these panels provide the designer with a broad palette to work from.

• Economical Alternative With several different compositions and finish options, GlazeGuard®

can provide an economical alternative to other glazing solutions while still providing aesthetic interest and value.

Page 6: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc.GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.comPRODUCT DATA SHEET

or other similar type channels whereall four edges are sealed. Thesepanels are not eligible for use as awall cladding and should not be usedin low grade areas with heavy traffic.No moldings are available withGlazeGuard® panels.

SYSTEM FINISHES:GlazeGuard® 250 WR panels areavailable with either smooth ortextured prefinished aluminum.

Standard colors in textured skins areoffered with a coil coated polyester.Premium colors are also availablewith an acrylic urethane coating.

Smooth standard and metallic colorsare furnished with a durable Kynar500® coating. Anodized finishes arealso standard.

Whether smooth or textured, bothfinishes can be ordered in customcolors to match customers’ standard.

3.51 kg/m²6mm

Panel Weight¹Nominal Thickness

TABLE 2. PANEL WEIGHT & THICKNESS:

0.72 lbs/ft²1/4”

R-ValueFlame SpreadStiffness (EI)¹Allowable BendingMoment¹Tensile Yield¹Ultimate Tensile¹

TABLE 3. PANEL PERFORMANCE:

1.32Class A3.68E+4

3.72E+1

6.24E+3

8.16E+3

---ASTM E84ASTM E72ASTM E72

ASTM E72ASTM E72

°F ft²/BTU---lb-in²/ft widthlb-ft/ft width

lb/ft widthlb/ft width

(1219mm x 2438mm)(1219mm x 3048mm)(1219mm x 3658mm)(1524mm x 2438mm)(1524mm x 3048mm)(1524mm x 3658mm)

48” x 96”48” x 120”48” x 144”60” x 96”60” x 120”60” x 144”

Cut-to-size panels are also available invirtually any size up to 60” x 144”.

SIZES AVAILABLE:Thickness:Length Dim:Width Dim:Squareness:

GlazeGuard® is supplied with clean,machine trimmed edges.

MATERIAL TOLERANCES:±1/32” (±0.79mm)+0, -1/8” (+0, -3.18mm)+0, -1/8” (+0, -3.18mm)1/64” (0.4mm) perlineal foot

LOAD DEFLECTION¹:

MetricComponent Standard

ValueProperty Test Unit

¹ Panel tested while supported on four sides.

5.0

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

0.5

0

De

fle

cti

on

(in

)

0

5.2

10

.4

15

.6

20

.8 26

31

.2

36

.4

41

.6

46

.8 52

57

.2

Load (psf)

4’x8’

4’x4’

PANEL FINISH SYSTEMS:

STANDARD WARRANTY:

Panel Warranty:Polyester/AcrylicFinish:

Kynar 500® Finish:

Anodized Finish:

5 Years5 YearsNo change greaterthan 6 for chalk,8 E units for fade20 YearsNo change greaterthan 8 for chalk,5 E units for fade20 Years (prorated)

Standard Textured:

Custom Textured:

Standard Smooth:

Custom Smooth:

Coil CoatedPolyesterSpray AppliedAcrylic UrethaneCoil CoatedKynar 500®

Spray AppliedKynar 500®

¹ Weight and testing based upon panels using an .010” textured face skin and an .010” textured back skin.

Page 7: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc. GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.com PRODUCT DATA SHEET

©2

00

5 C

ita

de

l A

rch

ite

ctu

ral

Pro

du

cts,

In

c.

An

IS

O 9

00

1:2

00

0 R

eg

iste

red

Co

mp

an

y.G

laze

Gu

ard

® is

a r

eg

iste

red

tra

de

ma

rk o

f C

itad

el A

rch

itect

ura

l Pro

du

cts,

In

c.P

rin

ted

In

Th

e U

.S.A

. F

orm

# 7

.08

.PD

.B

Re

v. (

03

/05

) S

up

ers

ed

es

(06

/03

)

Product Data Sheet

Metric (mm)

.254mm

.609mm

.390mm3.18mm16.6mm16.6mm

Component

Prefinished Textured Aluminum Skins(or) Prefinished Smooth Aluminum Skins(or) Porcelain Enamel Steel SkinsTempered Hardboard StabilizersExpanded Polystyrene Foam (EPS) Core(or) Polyisocyanurate Foam (ISO) Core

Standard (in)

.010”

.024” (min)28ga1/8”21/32”21/32”

••

¹ Technical Properties (see back) are based upon the Typical Composition. Selecting optional componentsmay alter these properties.

TABLE 1. COMPOSITION & MATERIALS1:

PRODUCT NAME:GlazeGuard® 1000Opaque Glazing Panels

MANUFACTURER:Citadel Architectural Products, Inc.3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400

(800) 446-8828fax: (317) 894-6333

(800) 247-2635web: www.citadelap.comemail: [email protected]

OVERVIEW:GlazeGuard® 1000 is a compositepanel made by laminating eithertextured or smooth aluminum skins(or porcelain enamel steel) totempered hardboard substrates.These stabilizers surround a coreof expanded polystyrene or poly-isocyanurate foam.

Panels are furnished with astrippable film (or interleafedmicrofoam) on the painted surfacesto protect the finish during shipmentand installation.

GlazeGuard® 1000 is installed inaluminum glazing/storefront chan-nels (typically on setting blocks) andsealed using gaskets. No mechani-cal fasteners or adhesives are usedin the installation of the panel.

BASIC USES & APPLICATIONS:As an alternative or complementto glass, GlazeGuard® panelsprovide an excellent choice for useas glazing infill, spandrel panels,modesty screens, and railing inserts.

These panels are typically used onvarious types of buildings includingschools and universities, retailcomplexes, storefront conditionsetc... However, with an impactresistant composition and a foamcore GlazeGuard® 1000 panels areideal for any other application whereincreased thermal properties,durability and safety are concerns.

PANEL & SYSTEMDESCRIPTION

FEATURES & BENEFITS:As a line of glazing infill solutions, GlazeGuard® offers a number ofbenefits to the building owner, architect, and installer including:

• Versatile With a complete line of options, GlazeGuard® panels offer solutions for water and fire resistant compositions in addition to the standard panel.

• Durable Whether installed in new or retrofit applications, the tempered hard- board stabilizers provide superior impact and dent resistance.

• Low Maintenance Little or no maintenance is required and most grease, dirt, oil, and other foreign material can be easily cleaned from the surface.

• Increased Thermal Value When compared to glass, GlazeGuard® offers an attractive alternative with increased R-values gained from panels 1” to 3-1/2” thick.

• Variety Of Finish Options GlazeGuard® panels are available in a wide range of colors and finishes. From solid tones in textured aluminum and porcelain enamel steel to metallic and anodized finishes in smooth skins, these panels provide the designer with a broad palette to work from.

Page 8: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc.GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.comPRODUCT DATA SHEET

10.2 kg/m²25mm

Panel Weight¹Nominal Thickness

TABLE 2. PANEL WEIGHT & THICKNESS:

2.08 lbs/ft²1”

R-ValueFlame SpreadStiffness (EI)¹Allowable BendingMoment¹Tensile Yield¹Ultimate Tensile¹

TABLE 3. PANEL PERFORMANCE:

4.6Class B8.69E+5

1.87E+2

6.24E+3

8.16E+3

---ASTM E84ASTM E72ASTM E72

ASTM E72ASTM E72

°F ft²/BTU---lb-in²/ft widthlb-ft/ft width

lb/ft widthlb/ft width

(1219mm x 2438mm)(1219mm x 3048mm)(1219mm x 3658mm)(1524mm x 2438mm)(1524mm x 3048mm)(1524mm x 3658mm)

48” x 96”48” x 120”48” x 144”60” x 96”60” x 120”60” x 144”

Cut-to-size panels are also available invirtually any size up to 60” x 144”.

SIZES AVAILABLE:Thickness:Length Dim:Width Dim:Squareness:

GlazeGuard® is supplied with clean,machine trimmed edges.

MATERIAL TOLERANCES:±1/32” (±0.79mm)+0, -1/8” (+0, -3.18mm)+0, -1/8” (+0, -3.18mm)1/64” (0.4mm) perlineal foot

LOAD DEFLECTION¹:

MetricComponent Standard

Value (EPS)Property Test Unit

GENERAL LIMITATIONS:GlazeGuard® panels are designed tobe installed in glazing channels orother similar type channels where allfour edges are sealed. The panelsare not eligible for use as a wallcladding or system. No moldings areavailable with GlazeGuard® panels.

SYSTEM FINISHES:GlazeGuard® 1000 panels areavailable with either smooth ortextured prefinished aluminum orporcelain enamel steel skins.

Standard colors in textured skins areoffered with a coil coated polyester.Premium colors are also availablewith an acrylic urethane coating.

Smooth standard and metallic colorsare furnished with a durable Kynar500® coating. Anodized finishes arealso standard.

Whether smooth or textured, bothfinishes can be ordered in customcolors to match customers’ standard.

Porcelain enamel steel is available inboth standard and premium colors.

¹ Panel tested while supported on four sides.

5.0

4.5

4.0

3.5

3.0

2.5

2.0

1.5

1.0

0.5

0

De

fle

cti

on

(in

)

0

5.2

10

.4

15

.6

20

.8 26

31

.2

36

.4

41

.6

46

.8 52

57

.2

Load (psf)

4’x8’

4’x4’

6.0Class A------

------

Value (ISO)

PANEL FINISH SYSTEMS:

STANDARD WARRANTY:

Panel Warranty:Polyester/AcrylicFinish:

Kynar 500® Finish:

Anodized Finish:Porcelain Steel:

5 Years5 YearsNo change greaterthan 6 for chalk,8 E units for fade20 YearsNo change greaterthan 8 for chalk,5 E units for fade20 Years (prorated)20 YearsNo chalkNo change greaterthan 5 E unitsfor fade

Standard Textured:

Custom Textured:

Standard Smooth:

Custom Smooth:

Coil CoatedPolyesterSpray AppliedAcrylic UrethaneCoil CoatedKynar 500®

(or) PorcelainEnamel SteelSpray AppliedKynar 500®

¹ Weight and testing based upon panels using an .010” textured face skin and an .010” textured back skin.

Page 9: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc. GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.com PRODUCT DATA SHEET

©2

00

5 C

ita

de

l A

rch

ite

ctu

ral

Pro

du

cts,

In

c.

An

IS

O 9

00

1:2

00

0 R

eg

iste

red

Co

mp

an

y.G

laze

Gu

ard

® is

a r

eg

iste

red

tra

de

ma

rk o

f C

itad

el A

rch

itect

ura

l Pro

du

cts,

In

c.P

rin

ted

In

Th

e U

.S.A

. F

orm

# 7

.09

.PD

.B

Re

v. (

03

/05

) S

up

ers

ed

es

(06

/03

)

Product Data Sheet

Metric (mm)

.254mm

.609mm4.00mm15.9mm15.9mm

Component

Prefinished Textured Aluminum Skins(or) Prefinished Smooth Aluminum SkinsHigh Density Polypropylene StabilizersExpanded Polystyrene Foam (EPS) Core(or) Polyisocyanurate Foam (ISO) Core

Standard (in)

.010”

.024” (min)5/32”5/8”5/8”

••

¹ Technical Properties (see back) are based upon the Typical Composition. Selecting optional componentsmay alter these properties.

TABLE 1. COMPOSITION & MATERIALS1:

PANEL & SYSTEMDESCRIPTION

PRODUCT NAME:GlazeGuard®1000 WRWater Resistant OpaqueGlazing Panels

MANUFACTURER:Citadel Architectural Products, Inc.3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400

(800) 446-8828fax: (317) 894-6333

(800) 247-2635web: www.citadelap.comemail: [email protected]

OVERVIEW:GlazeGuard® 1000 WR is a compos-ite panel made by laminating eithertextured or smooth aluminum skinsto high density polypropylenestabilizers. These plastic stabilizerssurround a core of expandedpolystyrene or polyisocyanuratefoam.

Panels are furnished with astrippable film (or interleafedmicrofoam) on the painted surfacesto protect the finish during shipmentand installation.

GlazeGuard® 1000 WR is installed inaluminum glazing/storefront chan-nels (typically on setting blocks) andsealed using gaskets. No mechani-cal fasteners or adhesives are usedin the installation of the panel.

BASIC USES & APPLICATIONS:As an alternative or complementto glass, GlazeGuard® panelsprovide an excellent choice for useas glazing infill, spandrel panels,modesty screens, and railing inserts.

These panels are typically used onvarious types of buildings includingschools and universities, retailcomplexes, storefront conditionsetc... However, with a water resistantcomposition and a foam core,GlazeGuard® 1000 WR panels areideal for other applications whereincreased thermal properties aredesired and incidental moistureintrusion may be possible.

FEATURES & BENEFITS:As a line of glazing infill solutions, GlazeGuard® offers a number ofbenefits to the building owner, architect, and installer including:

• Versatile GlazeGuard® panels offer solutions for water and fire resistant compositions in addition to the standard panel.

• Water Resistant Innovative polypropylene sta- bilizers make GlazeGuard® WR panels virtually unaffected by incidental moisture intrusion which may occur.

• Low Maintenance Little or no maintenance is required and most grease, dirt, oil, and other foreign material can be easily cleaned from the surface.

• Variety Of Finish Options GlazeGuard® panels are available in a wide range of colors and finishes. From solid tones in textured aluminum to metallic and anodized finishes in smooth skins, these panels provide the designer with a broad palette to work from.

• Economical Alternative With several different compositions and finish options, GlazeGuard®

can provide an economical alternative to other glazing solutions while still providing aesthetic interest and value.

Page 10: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc.GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.comPRODUCT DATA SHEET

(1219mm x 2438mm)(1219mm x 3048mm)(1219mm x 3658mm)(1524mm x 2438mm)(1524mm x 3048mm)(1524mm x 3658mm)

48” x 96”48” x 120”48” x 144”60” x 96”60” x 120”60” x 144”

Cut-to-size panels are also available invirtually any size up to 60” x 144”.

SIZES AVAILABLE:Thickness:Length Dim:Width Dim:Squareness:

GlazeGuard® is supplied with clean,machine trimmed edges.

MATERIAL TOLERANCES:±1/32” (±0.79mm)+0, -1/8” (+0, -3.18mm)+0, -1/8” (+0, -3.18mm)1/64” (0.4mm) perlineal foot

GENERAL LIMITATIONS:GlazeGuard® panels are designed tobe installed in glazing channels orother similar type channels where allfour edges are sealed. The panelsare not eligible for use as a wallcladding or system. No moldings areavailable with GlazeGuard® panels.

SYSTEM FINISHES:GlazeGuard® 1000 WR panels areavailable with either smooth ortextured prefinished aluminum skins.

Standard colors in textured skins areoffered with a coil coated polyester.Premium colors are also availablewith an acrylic urethane coating.

Smooth standard and metallic colorsare furnished with a durable Kynar500® coating. Anodized finishes arealso standard.

Whether smooth or textured, bothfinishes can be ordered in customcolors to match customers’ standard.

PANEL FINISH SYSTEMS:STANDARD WARRANTY:

Panel Warranty:Polyester/AcrylicFinish:

Kynar 500® Finish:

Anodized Finish:

5 Years5 YearsNo change greaterthan 6 for chalk,8 E units for fade20 YearsNo change greaterthan 8 for chalk,5 E units for fade20 Years (prorated)

Standard Textured:

Custom Textured:

Standard Smooth:

Custom Smooth:

Coil CoatedPolyesterSpray AppliedAcrylic UrethaneCoil CoatedKynar 500®

Spray AppliedKynar 500®

5.12 kg/m²25mm

Panel Weight¹Nominal Thickness

TABLE 2. PANEL WEIGHT & THICKNESS:

1.05 lbs/ft²1”

R-ValueFlame Spread

TABLE 3. PANEL PERFORMANCE:

4.08Class A

---ASTM E84

°F ft²/BTU---

MetricComponent Standard

Value (EPS)Property Test Unit

5.85Class A

Value (ISO)

¹ Panel weight based upon an .010” textured face skin and an .010” textured back skin.

Page 11: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc. GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.com PRODUCT DATA SHEET

©2

00

3 C

itad

el A

rch

itect

ura

l Pro

du

cts,

In

c.

An

IS

O 9

00

1:2

00

0 R

eg

iste

red

Co

mp

an

y.G

laze

Gu

ard

® is

a r

eg

iste

red

tra

de

ma

rk o

f C

itad

el A

rch

itect

ura

l Pro

du

cts,

In

c.P

rin

ted

In

Th

e U

.S.A

. F

orm

# 7

.10

.PD

.A

Re

v. (

06

/03

) S

up

ers

ed

es

(12

/98

)

Product Data Sheet

Metric (mm)

.254mm

.609mm

.390mm3.18mm4.76mm15.9mm

Component

Prefinished Textured Aluminum Skins²(or) Prefinished Smooth Aluminum Skins(or) Porcelain Enamel Steel Skins²Tempered Hardboard StabilizerPolyisocyanurate Foam (ISO) CoreType-X Exterior Grade Gypsum Board

Standard (in)

.010”

.024” (min)28ga1/8”3/16”5/8”

•••

¹ Technical Properties (see back) are based upon the Typical Composition. Selecting optional components may alter these properties.² Textured and porcelain skins available on face only. Backer must be .024” smooth aluminum.

TABLE 1. COMPOSITION & MATERIALS1:

PANEL & SYSTEMDESCRIPTION

PRODUCT NAME:GlazeGuard® 1000 FRFire Resistant OpaqueGlazing Panels

MANUFACTURER:Citadel Architectural Products, Inc.3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400

(800) 446-8828fax: (317) 894-6333

(800) 247-2635web: www.citadelap.comemail: [email protected]

OVERVIEW:GlazeGuard®1000 FR is a compositepanel made by laminating eithertextured or smooth aluminum skins(or porcelain enamel steel) to atempered hardboard stabilizer. Thisstabilizer, along with a Type-Xgypsum board, surround a coreof polyisocyanurate foam.

Panels are furnished with astrippable film (or interleafedmicrofoam) on the painted surfacesto protect the finish during shipmentand installation.

GlazeGuard®1000 FR is installed inaluminum glazing/storefront chan-nels (typically on setting blocks) andsealed using gaskets. No mechani-cal fasteners or adhesives are usedin the installation of the panel.

BASIC USES & APPLICATIONS:As an alternative or complementto glass, GlazeGuard® panelsprovide an excellent choice for useas glazing infill, spandrel panels,modesty screens/door light panels,and railing inserts. These panels aretypically used on various types ofbuildings including schools anduniversities, retail complexes,storefront conditions etc... However,with a fire resistant composition, animpact resistant stabilizer, and afoam core, GlazeGuard®1000 FRpanels are ideal for any otherapplication where increased thermalproperties, durability, and safety areconcerns.

FEATURES & BENEFITS:As a line of glazing infill solutions, GlazeGuard® offers a number ofbenefits to the building owner, architect, and installer including:

• Fire Resistant A Type-X gypsum board provides additional fire resistance for areas with more stringent requirements (i.e. educational facilities, etc.).

• Low Maintenance Little or no maintenance is required and most grease, dirt, oil, and other foreign material can be easily cleaned from the surface.

• Durable Whether installed in new or retrofit applications, the tempered hard- board stabilizer provides superior impact and dent resistance.

• Versatile With a complete line of options, GlazeGuard® panels offer solutions for water and fire resistant compositions in addition to the standard panel.

• Variety Of Finish Options GlazeGuard® panels are available in a wide range of colors and finishes. From solid tones in textured aluminum and porcelain enamel steel to metallic and anodized finishes in smooth skins, these panels provide the designer with a broad palette to work from.

Page 12: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc.GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.comPRODUCT DATA SHEET

(1219mm x 2438mm)(1219mm x 3048mm)(1219mm x 3658mm)

48” x 96”48” x 120”48” x 144”

Cut-to-size panels are also available invirtually any size up to 48” x 144”.

SIZES AVAILABLE:Thickness:Length Dim:Width Dim:Squareness:

GlazeGuard® is supplied with clean,machine trimmed edges.

MATERIAL TOLERANCES:±1/32” (±0.79mm)+0, -3/16” (+0, -4.76mm)+0, -3/16” (+0, -4.76mm)1/64” (0.4mm) perlineal foot

GENERAL LIMITATIONS:GlazeGuard® panels are designed tobe installed in glazing channels orother similar channels where all fouredges are sealed. The panels arenot eligible for use as a wall claddingor system. No moldings are avail-able for use with GlazeGuard®

panels.

SYSTEM FINISHES:GlazeGuard® 1000 FR panels areavailable with either smooth ortextured prefinished aluminum orporcelain enamel steel skins.

Standard colors in textured skins areoffered with a coil coated polyester.Premium colors are also availablewith an acrylic urethane coating.

Smooth standard and metallic colorsare furnished with a durable Kynar500® coating. Anodized finishes arealso standard.

Whether smooth or textured, bothfinishes can be ordered in customcolors to match customers’ standard.

Porcelain enamel steel is available inboth standard and premium colors.

PANEL FINISH SYSTEMS:

STANDARD WARRANTY:

Panel Warranty:Polyester/Acrylic:

Kynar 500® Finish:

Anodized Finish:Porcelain Steel:

5 Years5 YearsNo change greaterthan 6 for chalk,8 E units for fade20 YearsNo change greaterthan 8 for chalk,5 E units for fade20 Years (prorated)20 YearsNo chalkNo change greaterthan 5 E unitsfor fade

Standard Textured:

Custom Textured:

Standard Smooth:

Custom Smooth:

Coil CoatedPolyesterSpray AppliedAcrylic UrethaneCoil CoatedKynar 500®

(or) PorcelainEnamel SteelSpray AppliedKynar 500®

18.5 kg/m²25mm

Panel Weight¹Nominal Thickness

TABLE 2. PANEL WEIGHT & THICKNESS:

3.78 lbs/ft²1”

MetricComponent Standard

¹ Panel weight based upon an .010” textured face skin and an .024” smooth back skin.

R-ValueFlame Spread

TABLE 3. PANEL PERFORMANCE:

2.19Class A

---ASTM E84

°F ft²/BTU---

ValueProperty Test Unit

Page 13: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc. GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.com

Installation Guidelines

BE SURE TO READ, UNDERSTAND AND FOLLOW ALL GUIDELINES. Manufacturer guidelines may vary dependingupon specific application and project conditions. The manufacturer should be contacted with questions regardingconditions which vary from the guidelines set forth. Standard carpentry knowledge is required and good construc-tion practice for health, safety and welfare must be followed when installing GlazeGuard®.

INSTALLATION GUIDELINES 1

©2

00

3 C

itad

el A

rch

itect

ura

l Pro

du

cts,

In

c.

An

IS

O 9

00

1:2

00

0 R

eg

iste

red

Co

mp

an

y.G

laze

Gu

ard

® is

a r

eg

iste

red

tra

de

ma

rk o

f C

itad

el A

rch

itect

ura

l Pro

du

cts,

In

c.P

rin

ted

In

Th

e U

.S.A

. F

orm

# 7

.06

-10

.IN

.A

Re

v. (

06

/03

) S

up

ers

ed

es

(12

/98

)

VISUAL INSPECTION:Upon material arrival, all panel units should be visuallyinspected to verify that the product is in good conditionand free from shipping damage, weather damage ordefects.

Shipping damage and/or packaging issues should befirst noted on the bill of lading and then reported tothe distributor.

Should damage occur, the customer is responsiblefor filing a freight claim with the shipping companyWITHIN 24 HOURS from material receipt. Failure to doso may possibly result in forfeit of corrective action.

Any defective material should be reported directly tothe distributor from which the product was purchased.

NOTE:

MATERIAL INVENTORY:After verifying the condition of the product, inventory unitsagainst the packing slip to make sure that all material isreceived.

PRE-INSTALLATION:MATERIAL RECEIVING & INVENTORY

IS THE PRODUCT IN GOOD CONDITION?

IS THE PRODUCT CLEAN AND DRY?

IS THE PRODUCT FREE FROM DEFECTS?

ARE ALL OF THE PANEL UNITS PRESENT?

IS THE PIECE PER UNIT COUNT CORRECT?

Notify the distributor from which the product waspurchased of any missing or incomplete shipmentsIMMEDIATELY. Failure to do so may result in forfeit ofcorrective action.

NOTE:

FIGURE A.

TRANSPORTING THE MATERIAL:GlazeGuard® is packaged from the manufacturer inquantities of 40 pieces (or less) per unit (only 20 piecesper unit for GlazeGuard® 1000), under cover and securedwith metal strapping (FIG. A). If possible, panels shouldremain in this original packing for transport.

If a forklift or pallet jack is unavailable, panel unit may bebroken and carried to storage by hand according to thefollowing guidelines.

PRE-INSTALLATION:TRANSPORTING & HANDLING

HANDLING THE MATERIAL:A strippable protective film (or interleafed foam) isstandard on all panels. This film should remain on theproduct until instructed to take it off (during installation

UNITS ARE COVEREDWITH CARDBOARDAND SECUREDWITH METALSTRAPPING

WARNING: FAILURE TO FOLLOW THESE GUIDELINESWILL VOID THE STANDARD WARRANTY.

Page 14: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc.GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.com

MATERIAL STORAGE:If the units have been broken, material should berestacked, on a skid. Painted surfaces (strippable filmside) should be placed face to face and any interleafedfoam must be repositioned.

Failure to properly protect material from moistureintrusion may cause damage to the panel surfaceand/or core. Such damage is NOT covered under thestandard warranty.

NOTE:

If the material has become damp or wet during transpor-tation, the surface should be wiped dry before stacking toprevent any type of corrosion. Once the stacking iscompleted (or if the original packaging is still intact), theunits must be covered with a waterproof covering.

All units must be kept in a dry, well-ventilated area awayfrom exposure to the elements and/or any other construc-tion installations which may cause damage to theproduct.

PRE-INSTALLATION:STORING THE MATERIAL UNITS

2 INSTALLATION GUIDELINES

When handling panels, clean work gloves should beworn at all times to protect from sharp edges and toprevent any smudging of the painted finish.

When removing material from shipping units, DO NOTdrag/slide panels across stack underneath. Panelsmust be lifted up, then away to avoid any permanentdamage to the painted surface (FIG. C).

NOTE:

FIGURE B.

FIGURE C.

CLEARPROTECTIVEFILM

PREFINISHEDSURFACE

PANELS MUST BELIFTED UP & THEN AWAY,NOT ACROSS THE STACK

procedure). This strippable film (FIG. B) is designed toprevent minor abrasions to the surface. However, panelsshould still be handled with care to avoid any majordings, dents or scratches.

GENERAL WORK:LIMITATIONS OF THE PANEL SYSTEM

USES & APPLICATIONS:GlazeGuard® is intended for use as a replacement orcomplement to glass in new or retrofit construction. Thepanels are designed to be installed in glazing channels orother similar type channels where all four edges aresealed.

GENERAL WORK:FABRICATION OF THE PANELS

SAFETY PRECAUTIONS:When performing fabricating procedures, it is necessaryto observe all general guidelines for safety. Cutting,drilling, or otherwise machining the panels and trimmoldings may produce flying chips, shavings, or dust.

These panels are not eligible for use as a wallcladding system. No trim moldings, fasteners oraccessories are available with GlazeGuard®.

NOTE:

Page 15: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc. GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.com INSTALLATION GUIDELINES 3

CUTTING & DRILLING OF PANELS:Cut-to-size panels are available from the manufacturer.When field cutting is required, it may be performed usingstandard carpentry tools equipped with carbide-tippedblades. Work surfaces should be padded (FIG. D) andfree from any debris which may damage the finish. Forcleaner cuts, backer blocks and straightedges may be

clamped to the panel surface. Caul blocks should beused when necessary to protect the painted finish. Aftercutting, aluminum edges may need filing to remove sharpprojections and/or metal burrs (FIG. E) that might preventthe panel from sliding into the channel properly. Doing sowill also reduce the risk of personal injury.

FIGURE E.

FIGURE D.

WORK SURFACESTO BE PADDED

CAUL BLOCKSSHOULD BE USEDTO PROTECT FINISH

STRAIGHTEDGESSHOULD BE USEDFOR LONG CUTS

METAL BURRSSHOULD BE FILEDSMOOTH ALONGFACE SKIN

HOLD FILE AT ASLIGHT ANGLE

When using a table saw to cut panels, the finished side(protective film) should be placed facing upward. Forhand held circular saws and jigsaws, the finish sideshould be facing down (FIG. F). If working with customcolor panels and a protective film is not present, theinterleafed foam should be placed in a position to protectthe painted finish.

For drilling operations, the finished side should be placedfacing upward and a backer block should be used whennecessary to minimize any tearout.

FIGURE F.

CIRCULAR SAW - FINISH DOWN JIGSAW - FINISH DOWN

TABLE SAW - FINISH UP DRILLING - FINISH UP

In addition to work gloves and proper clothing, safetygoggles, ear protection, and possibly dust masks maybe needed when fabricating system components.

NOTE:

GENERAL WORK:INSTALLING THE PANELS

WORK SEQUENCE:GlazeGuard® panels should be cut-to-size for properinstallation. A standard 1/4” space should be allowedaround the perimeter of the glazing channel.

Before placing the panel into the channel, peel theprotective film away from the edges (approx. 4”-6”).

To prevent moisture intrusion, panels should be set on2” (approx.) long setting blocks (FIG. G). These blocksshould be set at quarter points at the bottom of the panel(appropriate block width determined by panel thickness).Installing GlazeGuard® panels framing systems with weepholes are preferred, as they aid in dispersing any inciden-tal moisture.

Verify glazing channel has depth capacity to accomodatethe 1/4” spacing needed around the perimeter of thepanel while allowing for a standard 1/2” edge grip.

To complete installation, seal perimeter joint with anacceptable wet seal compound or water tight gasket andcompletely remove the protective film.

Page 16: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc.GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.com4 INSTALLATION GUIDELINES

MAINTENANCE OF THEPANEL FINISH

REPAIR/TOUCH UP:Any minor scratches or dings which may occur duringinstallation can be repaired using touch-up paint availablefrom the manufacturer. Repainting of large areas with thetouch-up paint is not recommended. Finish characteris-tics of the repainted surface may vary from the prepaintedaluminum.

MAINTENANCE:Panels should be incorporated into an overall buildingwashing/maintenance schedule and cleaned in accor-dance with AAMA 610.1, Voluntary Guide Specificationfor Cleaning and Maintenance of Painted AluminumExtrusions and Curtain Wall Panels.

In general, panels may be cleaned using warm water anda mild detergrent (if necessary). For more aggressivematerials, a gentle brushing/scrubbing action may berequired. Abrasive detergents and/or harsh solventsshould not be used.

GENERAL WORK:THE PROTECTIVE FILM

GlazeGuard® panels have a protective film (or interleafedfoam) on all painted finishes. During installation, theprotective film is to be removed completely. For ease ofremoval, pull the film back against itself in the sameplane as the panel.

Failure to remove the protective film promptly afterinstallation (or exposure to long periods of sunlight)may cause difficulties in removal and possibly leave anadhesive residue.

NOTE:FIGURE G.

SETTING BLOCKGLAZING GASKETOR WET SEAL

THERMAL BREAK

Page 17: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc. GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.com GUIDE SPECIFICATION

B.

C.

1.06 SUBMITTALSA.

B.

Architectural AluminumManufacturer’s Association(AAMA):

Porcelain Enamel Institute (PEI):

(Specifier Note: Article belowincludes submittal of relevant datato be furnished by Contractoreither before, during or afterconstruction. Coordinate thisarticle with Architect’s andContractor’s duties and responsi-bilities in Conditions of theContract and Division 1 SubmittalProcedures Section.)

Samples:Panel: Two (2) 3”x 5” samples ofeach type of assembly.Color Standards: Two (2) 3”x 5”samples of each color of finishselected.

Shop Drawings: Indicate thicknessand dimension of parts, fasteningand anchoring methods, detailand location of joints, includingjoints necessary to accomodatethermal movement.

1.

2.

3.

AAMA 2603-98: VoluntarySpecification, PerformanceRequirements and TestProcedures for PigmentedOrganic Coatings on AluminumExtrusions and Panels.

AAMA 2605-98: VoluntarySpecification, PerformanceRequirements and TestProcedures for SuperiorPerforming Organic Coatingson Aluminum Extrusions andPanels

AAMA 611-98: VoluntarySpecification for AnodizedArchitectural Aluminum

PEI S-100: Specification forPorcelain Enamel on Steel

D.

E.

1.04 QUALITY ASSURANCEA.

B.

C.

D.

1.05 REFERENCESA.

SECTION 07415: EXTERIOR WALLPANELS & SYSTEMS

1.01 WORK INCLUDED

1.02 RELATED SECTIONSA.B.C.D.E.F.

1.03 SYSTEM DESCRIPTIONA.

B.

C.

Guide Specification

(Specifier Note: This is a guide specification for opaque glazing panels as manufactured by Citadel ArchitecturalProducts, Inc. and marketed under the trade names GlazeGuard® 250, GlazeGuard® 250 WR, GlazeGuard® 1000,GlazeGuard® 1000 WR and GlazeGuard® 1000 FR. Revise section number and title below to suit project requirements,specification practices and section content. Options are indicated by brackets { }: delete non-selected text in final copyof specification.)

PART 1: GENERAL

Section Includes: Laminatedpanels for use as glazing infill orrailing type channel inserts.

(Specifier Note: Revise articlebelow to suit project requirements.Add section numbers and title’sper specifier’s practice.)

Section 05100: Structural FramingSection 06100: Back Up WallsSection 07299: InsulationSection 07600: Metal FlashingSection 07920: SealantsSection 09200: Finishes

(Specifier Note: Revise articlebelow to suit project requirements.Restrict to statements describingdesign or performance require-ments of the complete wallsystem.)

Panel’s exposed finishes shallperform according to AAMA 2603-98 or AAMA 2605-98; exposedanodized aluminum according toAAMA 611-98; exposed porcelainenamel steel according toPEI S-100.

Panel composite assembly shallconform to ASTM E84, FlameSpread, Class A; Class B forGlazeGuard®1000 with EPS core.

Design wall system to withstand apositive and negative windloadpressure acting inward andoutward normal to the plane of thewall to meet the requirements ofthe latest adopted Local BuildingCode.

Make adequate provisions in thewall system for thermal expansionand contraction of the componentparts and fastening of the systemto prevent harmful damagecaused by buckling, opening ofjoints, expasion and contractiondue to accumulation of dead loadsand various live loads.

Design wall system to be sealedat all joints, intersections andcutouts to prevent moistureintrusion of any type.

Panel Manufacturer: Manufacturershall have a minimum of ten (10)years experience in the manufac-ture of composite architecturalwall systems and must haveISO 9001:2000 Certification.

Panel Installer: Installer shall beexperienced in performing work ofthis section and be specialized inthe installation of similar workrequired on this project.

Field Measurements: Whenpossible, measurements shouldbe taken prior to the completion ofshop manufacturing andassembly.

Pre-Installation Meetings: Conductpre-installation meetings to verifyproject requirements, substratecondition, installation instructions,and warranty requirements.Comply with Division 1 ProjectManagement and Coordination,Project Meetings Section.

(Specifier Note: Articles below listindustry standards referenced inthis section.)

American Society for Testing andMaterials (ASTM):

ASTM E84: Surface BurningCharacteristics

©2

00

5 C

ita

de

l A

rch

ite

ctu

ral

Pro

du

cts,

In

c.

An

IS

O 9

00

1:2

00

0 R

eg

iste

red

Co

mp

an

y.G

laze

Gu

ard

® is

a r

eg

iste

red

tra

de

ma

rk o

f C

itad

el A

rch

itect

ura

l Pro

du

cts,

In

c.P

rin

ted

In

Th

e U

.S.A

. F

orm

# 7

.06

-10

.SP

.B

Re

v. (

03

/05

) S

up

ers

ed

es

(06

/03

)

Page 18: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc.GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.comGUIDE SPECIFICATION

1.

2.

3.

Panel Composition:

Panel Tolerances:

Attachment System:To be used as glazing infill orinserted into an encapsulatingwatertight channel.

2.

3.

Panel Tolerances:

Attachment System:To be used as glazing infill orinserted into an encapsulatingwatertight channel.

Back Skin:{.010” prefinished texturedaluminum to matchArchitect’s color selection.}{.024” (minimum) prefinishedsmooth aluminum to matchArchitect’s color selection.}{28ga. porcelain enamelsteel}

Thickness: ±1/32”

Length and Width: +0, -1/8”

Squareness: 1/64” per linealfoot

c.

a.

b.

c.

B.

C.

2.01 EXTERIOR WALL PANELS &SYSTEMSA.

B.

a.

b.

Panel Lamination Warranty: Five(5) years commencing on Date ofSubstantial Completion.

Finish Warranty:{Polyester: Five (5) years}{Acrylic Urethane: Five (5) years}{Kynar 500®: Twenty (20) years}{Kynar 500® Metallic: Twenty (20)years}{Anodized: Twenty (20) years}{Porcelain Enamel Steel: Twenty(20) years}

(Specifier Note: Select productparagraph below to suit projectrequirements. Add productattributes, performance character-istics, material standards anddescriptions as applicable. Use ofsuch phrases as “or equal” and “orapproved equal” may causeambiguity in the specifications.Such phrases require verifica-tion—procedural, legal, regulatory,and responsibility—for determin-ing equivalence of products.)

Manufacturer:Citadel Architectural Products, Inc3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400

(800) 446-8828fax: (317) 894-6333

(800) [email protected]

{GlazeGuard® 250 - OpaqueGlazing Panels}1. Panel Composition:

Face Skin:{.010” prefinished texturedaluminum to matchArchitect’s color selection.}{.024” (minimum) prefinishedsmooth aluminum to matchArchitect’s color selection.}{28ga. porcelain enamelsteel}

Core:3/16” tempered hardboard

C.

D.

E.

1.07 DELIVERY, STORAGE ANDHANDLINGA.

B.

C.

D.

1.08 WARRANTYA.

Material Certification: Two (2)copies certifying that materialmeets the requirements specified.

Manufacturer’s Literature: Two (2)copies of manufacturer’s literaturefor panel material.

Test Reports: Two (2) copies ofthird party test reports on testingrequired in Section 1.03.

(Specifier Note: Article belowshould include special and uniquerequirements. Coordinate articlebelow with Division 1 ProductRequirements Section.)

General: Comply with Division 1Product Requirements Section.

Delivery: Package all panels forprotection against transportationdamage in accordance withmanufacturer’s requirements.

Storage: Store all materials inaccordance with manufacturer’sinstallation instructions. Stackmaterials on pallets or platforms,covered with suitable ventilatedcovering. Do not store panelswhere accumulation of water mayoccur or in contact with othermaterials that might causestaining, denting or other damage.

Handling: All materials should behandled in a manner to preventdamage to the product in accor-dance with manufacturer’sinstallation instructions.

(Specifier Note: Coordinate articlebelow with Condition of theContract and with Division 1Closeout Submittals [Warranty]Section.)

Manufacturer’s Warranty: Furnishpanel manufacturer’s standardlimited warranty documentexecuted by an authorizedcompany official. Manufacturer’swarranty is in addition to and not alimitation of other rights Ownermay have under the ContractDocuments.

PART 2: PRODUCTS

{GlazeGuard® 250 WR - WaterResistant Opaque Glazing Panels}

a.

b.

c.

a.

b.

c.

Face Skin:{.010” prefinished texturedaluminum to matchArchitect’s color selection.}{.024” (minimum) prefinishedsmooth aluminum to matchArchitect’s color selection.}

Core:6mm high densitypolypropylene

Back Skin:{.010” prefinished texturedaluminum to matchArchitect’s color selection.}{.024” (minimum) prefinishedsmooth aluminum to matchArchitect’s color selection.}

Thickness: ±1/32”

Length and Width: +0, -1/8”

Squareness: 1/64” per linealfoot

Page 19: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc. GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.com GUIDE SPECIFICATION

1.

2.

3.

Panel Composition:

Panel Tolerances:

Attachment System:To be used as glazing infill orinserted into an encapsulatingwatertight channel.

2.

3.

Panel Tolerances:

Attachment System:To be used as glazing infill orinserted into an encapsulatingwatertight channel.

1. Panel Composition:

a.

b.

c.

d.

e.

a.

b.

c.

Face Skin:{.010” prefinished texturedaluminum to matchArchitect’s color selection.}{.024” (minimum) prefinishedsmooth aluminum to matchArchitect’s color selection.}{28ga. porcelain enamelsteel}

Face Stabilizer:1/8” tempered hardboard

Core:{21/32” expanded polysty-rene (EPS) foam}{21/32” polyisocyanurate(ISO) foam}

Back Stabilizer:1/8” tempered hardboard

Back Skin:{.010” prefinished texturedaluminum to matchArchitect’s color selection.}{.024” (minimum) prefinishedsmooth aluminum to matchArchitect’s color selection.}{28ga. porcelain enamelsteel}

Thickness: ±1/32”

Length and Width: +0, -1/8”

Squareness: 1/64” per linealfoot

2.

3.

2.02 SUBSTITUTIONSA.

B.

C.

D.

2.03 FINISHA.

B.

(Specifier Note: Revise articlebelow to suit project requirements.If substitutions are permitted, edittext below. Add text to refer toDivision 1 Project Requirements,Product Substitutions ProceduresSection.)

Acceptable Alternatives: Panels ofsimilar composition providingmanufacturer has a minimum often (10) years experience.

The materials and productsspecified in this section establisha standard of required function,dimension, appearance, andquality to be met by any proposedsubstitution.

No substitution will be consideredunless written request for approvalhas been submitted by the bidderand has been received by theArchitect ten (10) days prior to thedate for receipt of bids.

Each request shall include thename of the materials and acomplete description of theproposed material, including testperformance and any otherinformation necessary forevaluation.

Exposed Finish:{Polyester}{Acrylic Urethane}{Kynar 500®}{Kynar 500® Metallic}{Anodized}{Porcelain Enamel Steel}

Color: As selected by the Architectfrom panel manufacturer’s ColorSelection Guide.

a.

b.

c.

Panel Tolerances:

Attachment System:To be used as glazing infill orinserted into an encapsulatingwatertight channel

Thickness: ±1/32”

Length & Width: +0, -3/16”

Squareness: 1/64” per linealfoot

{GlazeGuard® 1000 - OpaqueGlazing Panels}

a.

b.

Face Skin:{.010” prefinished texturedaluminum to matchArchitect’s color selection.}{.024” (minimum) prefinishedsmooth aluminum to matchArchitect’s color selection.}

Face Stabilizer:4mm high densitypolypropylene

{GlazeGuard® 1000 WR - WaterResistant Opaque Glazing Panels}

c.

d.

e.

a.

b.

c.

Core:{5/8” expanded polystyrene(EPS) foam}{5/8” polyisocyanurate (ISO)foam}

Back Stabilizer:4mm high densitypolypropylene

Back Skin:{.010” prefinished texturedaluminum to matchArchitect’s color selection.}{.024” (minimum) prefinishedsmooth aluminum to matchArchitect’s color selection.}

Thickness: ±1/32”

Length and Width: +0, -1/8”

Squareness: 1/64” per linealfoot

1. Panel Composition:a.

b.

c.

d.

e.

Face Skin:{.010” prefinished texturedaluminum to matchArchitect’s color selection.}{.024” (minimum) prefinishedsmooth aluminum to matchArchitect’s color selection.}{28ga. porcelain enamelsteel}

Face Stabilizer:1/8” tempered hardboard

Core:3/16” polyisocyanurate foam

Back Stabilizer:5/8” type-x exterior gradegypsum board

Back Skin:.024” (minimum) prefinishedsmooth aluminum to matchArchitect’s color selection

{GlazeGuard® 1000 FR - FireResistant Opaque Glazing Panels}

Page 20: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc.GlazeGuard®

Call (800) 446-8828 or visit www.citadelap.comGUIDE SPECIFICATION

2.04 ACCESSORIES

3.01 EXAMINATIONA.

B.

C.

Weather Seals: Shall be Tremco®

Spectrem® 2, applied per thesealant manufacturer’s guidelinesand in accordance with the panelmanufacturer’s installationinstructions.

(Specifier Note: Revise articlebelow to suit project requirementsand specifier’s practice.)

Examine and verify substratesurfaces to receive compositemetal panel system and associ-ated work and condition whichwork will be installed.

Maximum deviation from verticaland horizontal alignment ofsubstrate shall be no more than1/4” in 20’-0”.

Do not proceed with work untilunsatisfactory conditions havebeen corrected in a manneracceptable to installer. Startingwork within a particular area willbe construed as installer’sacceptance of surface conditions.

PART 3: EXECUTION

3.02 PREPARATIONA.

B.

C.

D.

3.03 INSTALLATIONA.

B.

C.

Comply with manufacturer’sproduct data including producttechnical bulletins, productcatalog installation instructions,and product carton instructions.

Surfaces to receive panels shallbe even, smooth, sound, clean,and free from defects detrimentalto panel installation.

Field measure and verify dimen-sions as required.

Protect adjacent areas or surfacesfrom damage as a result of thework of this section.

(Specifier Note: Coordinate articlebelow with panel manufacturer’srecommended installation details.)

Sheathing and water resistantmembrane (if specified) by others.

Erect panels level and true tointended plane.

Maximum deviation from verticaland horizontal alignment oferected panel system shall be nomore than 1/4” in 20’-0”.

D.

E.

F.

3.04 CLEANINGA.

B.

END OF SECTION

Maximum deviation in panelflatness shall be 0.6% of theassembled units.

Conform to panel manufacturer’sinstallation instructions forattachment systems.

Weather seal all joints as requiredusing methods and materials asrecommended by the panelmanufacturer’s installationinstructions.

(Specifier Note: Coordinate articlebelow with Division 1 ExecutionRequirements, Cleaning Section.)

Remove temporary coverings andprotection to adjacent work areas.Repair or replace damagedinstalled products. Clean installedproducts in accordance withmanufacturer’s instructions priorto Owner’s acceptance.

Remove and legally dispose ofconstruction debris from projectsite.

Page 21: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

SAMPLE

GLAZEGUARD® PRODUCT WARRANTY

Citadel Architectural Products, Inc., 3131-A North Franklin Road, Indianapolis, Indiana 46226

©2003 Citadel Architectural Products, Inc. GlazeGuard® is a registered trademark of Citadel Architectural Products, Inc.Printed In The U.S.A. Form # 7.06-10.WR1.A Rev. (06/03) Supersedes (12/98)

(POLYESTER FINISH OR EQUIVALENT)

PROJECT:

LOCATION:

DATE:

Citadel warrants that: (a) at the time the Panels are delivered to theabove-described Project Site (the “Delivery Date”), the Panels will meetCitadel’s standard specifications then in effect; (b) the Panels will notdelaminate for a period of five (5) years from the Delivery Date; (c) theexterior painted finish of the Panels will not have a Chalk Rating of lessthan 6 or a Fade Differential of greater than 8E units (Hunter Color Dif-ference) for a period of five (5) years from the Delivery Date; and (d) thefinish of the Panels will not check, peel, lose adhesion or fracture (otherthan minute fractures which may develop due to fabrication and whichare acceptable by industry standards on the Delivery Date) for a periodof five (5) years from the Delivery Date.

For purposes of this Warranty: (a) “Chalk Rating” means the ratingcalculated by using the Method of Evaluating Degree of Chalking of Ex-terior Paint (per ATSM D4214-98); and (b) “Fade Differential” meansthe difference between the color value as measured on exposed paintedsurfaces that have been cleaned of external deposits and chalk and thecorresponding color value measured on the original unexposed paintedsurfaces; and (c) a Panel has a “Defect” and is “Defective” if it does notconform to this Warranty. Unequal fading or finish color changes result-ing from unequal exposure of surfaces to the sun or other exterior ele-ments or conditions are not Defects.

THIS WARRANTY DOES NOT COVER DEFECTS CAUSED BY:Exposure to smoke, fire, radiation, salt spray, chemicals, harmful or for-eign substances in the atmosphere, including but not limited to organicsolvents, concentrated detergents, wetting agents or sulfur dioxide emis-sion levels above those deemed safe by the U.S. Environmental Protec-tion Agency.

Negligence; improper maintenance; abuse; impact or other physical force,whether prior or subsequent to installation; normal wear and tear andweathering; fire, lightning, tornadoes, or other acts of God.

Defective or damaged fasteners, extrusions, brackets or fabricated ap-plications attached to or used in connection with installation of the Pan-els, or Defects in the Panels caused by such fasteners, extrusions, brack-ets or fabricated applications.

Failure to adequately seal edges and joints of the Panels or to apply anapproved sealant in its proper amount in accordance with Citadel’sGlazeGuard® Installation Guide.

Improper installation or sizing of the Panels, including moisture intru-sion, water and air leakage as a result of improper installation or sizing.

Damage incurred after the Delivery Date during storage, handling, in-stallation or maintenance of any of the Panels.

This Warranty is given by Citadel Architectural Products, Inc. (“Citadel”) to the initial owner and subsequent owners (“Owner”) of the structure onwhich GlazeGuard® panels (individually, a “Panel” and collectively, the “Panels”) are first installed.

DISCLAIMER OF WARRANTIES:THIS WARRANTY IS THE EXCLUSIVE WARRANTY GIVEN BY CITA-DEL FOR THE PANELS. CITADEL DISCLAIMS ALL OTHER WARRAN-TIES, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDINGANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FIT-NESS FOR A PARTICULAR PURPOSE AND ANY IMPLIED WARRAN-TIES ARISING FROM A COURSE OF DEALING OR USAGE OF TRADE.THIS WARRANTY SUPERSEDES ALL OTHER WARRANTIES, IN-CLUDING ANY WARRANTIES BASED ON ORAL REPRESENTATIONS.

OWNER’S REMEDIES:For this Warranty to be valid, Owner must complete and return Citadel’sProduct Warranty Request Form within thirty (30) days of completion ofinstallation of the Panels at the above-described Project Site and shalldocument in writing its maintenance and cleaning of the Panels, andprovide such documentation to Citadel upon request. To make a claimunder this Warranty, Owner must send a written description of any claimedDefect (the “Claimed Defect”) to Citadel in writing at its address shownbelow within thirty (30) days of discovery of the Claimed Defect. Uponthe request of Citadel, Owner shall permit Citadel reasonable time toinspect Panels for which notice of a Claimed Defect has been givenprior to any removal, repair or replacement of the Panels. Any failure ofOwner to notify Citadel of a Claimed Defect or to afford Citadel a rea-sonable opportunity to inspect the Claimed Defect prior to taking anyremedial measures (including removal, repair or replacement) shall ren-der this Warranty void in its entirety and the Claimed Defect shall not becovered by this Warranty. If the Claimed Defect is a Defect covered bythis Warranty, Citadel, at its option, will do one of the following within areasonable period of time: (1) refinish or repair the Defective Panel;(2) furnish a conforming Panel to replace the Defective Panel; or (3) re-fund a prorated portion of the price paid to Citadel for the Defective Panel.In determining the amount of any refund to be paid by Citadel for a De-fective Panel, the original price paid to Citadel for such Defective Panelshall be reduced by 20% for each full year which has passed since theDelivery Date for delamination Defects covered by this Warranty and20% for each full year which has passed since the Delivery Date for allother Defects covered by this Warranty. Owner shall bear all costs ofremoval and disposal of Defective Panels and installation of all replace-ment Panels provided by Citadel.

THE REMEDIES SET FORTH HEREIN SHALL BE THE EXCLUSIVEAND SOLE REMEDIES OF OWNER FOR BREACH OF THIS WAR-RANTY AND FOR DEFECTS COVERED BY THIS WARRANTY.

EXCLUSION OF CONSEQUENTIAL AND OTHER DAMAGES:IN NO EVENT SHALL CITADEL BE LIABLE FOR ANY INCIDENTAL,INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER RESULTINGFROM THE USE, MISUSE OR INABILITY TO USE OR INSTALL THEPANELS OR FROM DEFECTS IN THE PANELS.

Page 22: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value
Page 23: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

SAMPLE

GLAZEGUARD® PRODUCT WARRANTY

Citadel Architectural Products, Inc., 3131-A North Franklin Road, Indianapolis, Indiana 46226

©2003 Citadel Architectural Products, Inc. GlazeGuard® is a registered trademark of Citadel Architectural Products, Inc.Printed In The U.S.A. Form # 7.06-10.WR2.A Rev. (06/03) Supersedes (12/98)

(KYNAR 500® & ANODIZED FINISHES)

PROJECT:

LOCATION:

DATE:

Citadel warrants that: (a) at the time the Panels are delivered to theabove-described Project Site (the “Delivery Date”), the Panels will meetCitadel’s standard specifications then in effect; (b) the Panels will notdelaminate for a period of five (5) years from the Delivery Date; (c) theexterior painted finish of the Panels will not have a Chalk Rating of lessthan 8 or a Fade Differential of greater than 5E units (Hunter Color Dif-ference) for a period of twenty (20) years from the Delivery Date; and (d)the finish of the Panels (either painted or anodized) will not check, peel,lose adhesion or fracture (other than minute fractures which may de-velop due to fabrication and which are acceptable by industry standardson the Delivery Date) for a period of twenty (20) years from the DeliveryDate.

For purposes of this Warranty: (a) “Chalk Rating” means the ratingcalculated by using the Method of Evaluating Degree of Chalking of Ex-terior Paint (per ATSM D4214-98); and (b) “Fade Differential” meansthe difference between the color value as measured on exposed paintedsurfaces that have been cleaned of external deposits and chalk and thecorresponding color value measured on the original unexposed paintedsurfaces; and (c) a Panel has a “Defect” and is “Defective” if it does notconform to this Warranty. Unequal fading or finish color changes result-ing from unequal exposure of surfaces to the sun or other exterior ele-ments or conditions and gradual color changes in anodized Panel finishfrom normal weathering are not Defects.

THIS WARRANTY DOES NOT COVER DEFECTS CAUSED BY:Exposure to smoke, fire, radiation, salt spray, chemicals, harmful or for-eign substances in the atmosphere, including but not limited to organicsolvents, concentrated detergents, wetting agents or sulfur dioxide emis-sion levels above those deemed safe by the U.S. Environmental Protec-tion Agency.

Negligence; improper maintenance; abuse; impact or other physical force,whether prior or subsequent to installation; normal wear and tear andweathering; fire, lightning, tornadoes, or other acts of God.

Failure of Owner to clean anodized Panel finish at least once a year, ora failure of Owner to perform all maintenance and cleaning in accor-dance with AAMA 610.1, Voluntary Guide Specification for Cleaning andMaintenance of Painted Aluminum Extrusions and Curtain Wall Panels.

Defective or damaged fasteners, extrusions, brackets or fabricated ap-plications attached to or used in connection with installation of the Pan-els, or Defects in the Panels caused by such fasteners, extrusions, brack-ets or fabricated applications.

Failure to adequately seal edges and joints of the Panels or to apply anapproved sealant in its proper amount in accordance with Citadel’sGlazeGuard® Installation Guide.

Improper installation or sizing of the Panels, including moisture intru-sion, water and air leakage as a result of improper installation or sizing.

Damage incurred after the Delivery Date during storage, handling, in-stallation or maintenance of any of the Panels.

This Warranty is given by Citadel Architectural Products, Inc. (“Citadel”) to the initial owner and subsequent owners (“Owner”) of the structure onwhich GlazeGuard® panels (individually, a “Panel” and collectively, the “Panels”) are first installed.

DISCLAIMER OF WARRANTIES:THIS WARRANTY IS THE EXCLUSIVE WARRANTY GIVEN BY CITA-DEL FOR THE PANELS. CITADEL DISCLAIMS ALL OTHER WARRAN-TIES, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDINGANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FIT-NESS FOR A PARTICULAR PURPOSE AND ANY IMPLIED WARRAN-TIES ARISING FROM A COURSE OF DEALING OR USAGE OF TRADE.THIS WARRANTY SUPERSEDES ALL OTHER WARRANTIES, IN-CLUDING ANY WARRANTIES BASED ON ORAL REPRESENTATIONS.

OWNER’S REMEDIES:For this Warranty to be valid, Owner must complete and return Citadel’sProduct Warranty Request Form within thirty (30) days of completion ofinstallation of the Panels at the above-described Project Site and shalldocument in writing its maintenance and cleaning of the Panels, andprovide such documentation to Citadel upon request. To make a claimunder this Warranty, Owner must send a written description of any claimedDefect (the “Claimed Defect”) to Citadel in writing at its address shownbelow within thirty (30) days of discovery of the Claimed Defect. Uponthe request of Citadel, Owner shall permit Citadel reasonable time toinspect Panels for which notice of a Claimed Defect has been givenprior to any removal, repair or replacement of the Panels. Any failure ofOwner to notify Citadel of a Claimed Defect or to afford Citadel a rea-sonable opportunity to inspect the Claimed Defect prior to taking anyremedial measures (including removal, repair or replacement) shall ren-der this Warranty void in its entirety and the Claimed Defect shall not becovered by this Warranty. If the Claimed Defect is a Defect covered bythis Warranty, Citadel, at its option, will do one of the following within areasonable period of time: (1) refinish or repair the Defective Panel;(2) furnish a conforming Panel to replace the Defective Panel; or (3) re-fund a prorated portion of the price paid to Citadel for the Defective Panel.In determining the amount of any refund to be paid by Citadel for a De-fective Panel, the original price paid to Citadel for such Defective Panelshall be reduced by 20% for each full year which has passed since theDelivery Date for delamination Defects covered by this Warranty and5% for each full year which has passed since the Delivery Date for allother Defects covered by this Warranty. Owner shall bear all costs ofremoval and disposal of Defective Panels and installation of all replace-ment Panels provided by Citadel.

THE REMEDIES SET FORTH HEREIN SHALL BE THE EXCLUSIVEAND SOLE REMEDIES OF OWNER FOR BREACH OF THIS WAR-RANTY AND FOR DEFECTS COVERED BY THIS WARRANTY.

EXCLUSION OF CONSEQUENTIAL AND OTHER DAMAGES:IN NO EVENT SHALL CITADEL BE LIABLE FOR ANY INCIDENTAL,INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER RESULTINGFROM THE USE, MISUSE OR INABILITY TO USE OR INSTALL THEPANELS OR FROM DEFECTS IN THE PANELS.

Page 24: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value
Page 25: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

SAMPLE

GLAZEGUARD® PRODUCT WARRANTY

Citadel Architectural Products, Inc., 3131-A North Franklin Road, Indianapolis, Indiana 46226

©2003 Citadel Architectural Products, Inc. GlazeGuard® is a registered trademark of Citadel Architectural Products, Inc.Printed In The U.S.A. Form # 7.06-10.WR3.A Rev. (06/03) Supersedes (12/98)

(PORCELAIN ENAMEL FINISH)

PROJECT:

LOCATION:

DATE:

Citadel warrants that: (a) at the time the Panels are delivered to theabove-described Project Site (the “Delivery Date”), the Panels will meetCitadel’s standard specifications then in effect; (b) the Panels will notdelaminate for a period of five (5) years from the Delivery Date; (c) theexterior porcelain finish of the Panels will not exhibit excessive fading ofcolor, crazing, cracking, or flaking (other than minute fractures whichmay develop due to fabrication and which are acceptable by industrystandards on the Delivery Date) for a period of twenty (20) years fromthe Delivery Date.

For purposes of this Warranty: (a) “Chalk Rating” means the ratingcalculated by using the Method of Evaluating Degree of Chalking of Ex-terior Paint (per ATSM D4214-98); and (b) “Fade Differential” meansthe difference between the color value as measured on exposed paintedsurfaces that have been cleaned of external deposits and chalk and thecorresponding color value measured on the original unexposed paintedsurfaces; and (c) a Panel has a “Defect” and is “Defective” if it does notconform to this Warranty. Unequal fading or finish color changes result-ing from unequal exposure of surfaces to the sun or other exterior ele-ments or conditions and gradual color changes in anodized Panel finishfrom normal weathering are not Defects.

THIS WARRANTY DOES NOT COVER DEFECTS CAUSED BY:Exposure to smoke, fire, radiation, salt spray, chemicals, harmful or for-eign substances in the atmosphere, including but not limited to organicsolvents, concentrated detergents, wetting agents or sulfur dioxide emis-sion levels above those deemed safe by the U.S. Environmental Protec-tion Agency.

Negligence; improper maintenance; abuse; impact or other physical force,whether prior or subsequent to installation; normal wear and tear andweathering; fire, lightning, tornadoes, or other acts of God.

Defective or damaged fasteners, extrusions, brackets or fabricated ap-plications attached to or used in connection with installation of the Pan-els, or Defects in the Panels caused by such fasteners, extrusions, brack-ets or fabricated applications.

Failure to adequately seal edges and joints of the Panels or to apply anapproved sealant in its proper amount in accordance with Citadel’sGlazeGuard® Installation Guide.

Improper installation or sizing of the Panels, including moisture intru-sion, water and air leakage as a result of improper installation or sizing.

Damage incurred after the Delivery Date during storage, handling, in-stallation or maintenance of any of the Panels.

This Warranty is given by Citadel Architectural Products, Inc. (“Citadel”) to the initial owner and subsequent owners (“Owner”) of the structure onwhich GlazeGuard® panels (individually, a “Panel” and collectively, the “Panels”) are first installed.

DISCLAIMER OF WARRANTIES:THIS WARRANTY IS THE EXCLUSIVE WARRANTY GIVEN BY CITA-DEL FOR THE PANELS. CITADEL DISCLAIMS ALL OTHER WARRAN-TIES, WHETHER EXPRESS, IMPLIED OR STATUTORY, INCLUDINGANY WARRANTY OF MERCHANTABILITY, ANY WARRANTY OF FIT-NESS FOR A PARTICULAR PURPOSE AND ANY IMPLIED WARRAN-TIES ARISING FROM A COURSE OF DEALING OR USAGE OF TRADE.THIS WARRANTY SUPERSEDES ALL OTHER WARRANTIES, IN-CLUDING ANY WARRANTIES BASED ON ORAL REPRESENTATIONS.

OWNER’S REMEDIES:For this Warranty to be valid, Owner must complete and return Citadel’sProduct Warranty Request Form within thirty (30) days of completion ofinstallation of the Panels at the above-described Project Site and shalldocument in writing its maintenance and cleaning of the Panels, andprovide such documentation to Citadel upon request. To make a claimunder this Warranty, Owner must send a written description of any claimedDefect (the “Claimed Defect”) to Citadel in writing at its address shownbelow within thirty (30) days of discovery of the Claimed Defect. Uponthe request of Citadel, Owner shall permit Citadel reasonable time toinspect Panels for which notice of a Claimed Defect has been givenprior to any removal, repair or replacement of the Panels. Any failure ofOwner to notify Citadel of a Claimed Defect or to afford Citadel a rea-sonable opportunity to inspect the Claimed Defect prior to taking anyremedial measures (including removal, repair or replacement) shall ren-der this Warranty void in its entirety and the Claimed Defect shall not becovered by this Warranty. If the Claimed Defect is a Defect covered bythis Warranty, Citadel, at its option, will do one of the following within areasonable period of time: (1) refinish or repair the Defective Panel;(2) furnish a conforming Panel to replace the Defective Panel; or (3) re-fund a prorated portion of the price paid to Citadel for the Defective Panel.In determining the amount of any refund to be paid by Citadel for a De-fective Panel, the original price paid to Citadel for such Defective Panelshall be reduced by 20% for each full year which has passed since theDelivery Date for delamination Defects covered by this Warranty and5% for each full year which has passed since the Delivery Date for allother Defects covered by this Warranty. Owner shall bear all costs ofremoval and disposal of Defective Panels and installation of all replace-ment Panels provided by Citadel.

THE REMEDIES SET FORTH HEREIN SHALL BE THE EXCLUSIVEAND SOLE REMEDIES OF OWNER FOR BREACH OF THIS WAR-RANTY AND FOR DEFECTS COVERED BY THIS WARRANTY.

EXCLUSION OF CONSEQUENTIAL AND OTHER DAMAGES:IN NO EVENT SHALL CITADEL BE LIABLE FOR ANY INCIDENTAL,INDIRECT OR CONSEQUENTIAL DAMAGES, WHETHER RESULTINGFROM THE USE, MISUSE OR INABILITY TO USE OR INSTALL THEPANELS OR FROM DEFECTS IN THE PANELS.

Page 26: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value
Page 27: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value
Page 28: PRODUCT MANUAL Rev. (11/06) · 2017-08-10 · ASTM E84 ASTM E72 ASTM E72 ASTM E72 ASTM E72 °F ft²/BTU---lb-in²/ft width lb-ft/ft width lb/ft width lb/ft width Property Test Value

Citadel Architectural Products, Inc.3131-A North Franklin RoadIndianapolis, Indiana 46226phone: (317) 894-9400

(800) 446-8828fax: (317) 894-6333

(800) [email protected]

©2006 Citadel Architectural Products, Inc. All Rights Reserved.An ISO 9001:2000 Registered Company.

Panel 15®, SinoCore®, Panel 20®, Envelope 2000®, GlazeGuard®, CleanCote®, BioWall® and Xylem® areregistered trademarks of Citadel Architectural Products, Inc. ProCore™, Premier™, Guardian™ andSentinel™ are trademarks of Citadel Architectural Products, Inc.


Recommended